Attachment_3 _Past_Performance_Summary_Sheet_(PPSS)_17_Feb_16.docx

DOCX document 18 KB Posted

Attached to
Base Civil Engineer Services Federal contract opportunity
Solicitation number
FA4814-16-R-0005
Issued by
Department of the Air Force Air Mobility Command

About this file

Attachment 3

View the file

Other files for this federal contract opportunity

Other files attached to Base Civil Engineer Services, newest first.
File Type Posted
Q A_RPES_Clarification.pdf PDF
Q A.pdf PDF
SF_30.pdf PDF
Attachment_6_V3.pdf PDF
Appendix_4_3_V2.xls XLS spreadsheet
Appendix_4.7_V2.xlsx XLSX spreadsheet
Appendix_4.4_(Part_2)_V2.doc DOC document
Attachment_4_V2_21_Mar.xlsx XLSX spreadsheet
SF_30.pdf PDF
Asbuilt_shore_exclusion_zone.pdf PDF
Funded_Electrical_Projects.xlsx XLSX spreadsheet
PWS_Questions_FBO.pdf PDF
HVAC_Inventory_-_8_Mar_16.xlsx XLSX spreadsheet
FY15_Work_Order_hours.xlsx XLSX spreadsheet
Electrical_overhead_inventory.xlsx XLSX spreadsheet
HVAC_IWIMS_Inventory_Mar_2016.xlsx XLSX spreadsheet
ppi_tool.accdb —
Sign_in_sheet_and_map.pdf PDF
Site_Visit_Briefing_Slides_V3.ppt PPT presentation
PAPerspectivesBrief_Updated_II.pptx PPTX presentation
Attachment_6_1_March_16.pdf PDF
SF_30.pdf PDF
IAP_IAMAW_CBA_1_Oct_2015.pdf PDF
Akima_IAMAW_CBA_1_Oct_2015.pdf PDF
Appendix_4.2_G-01-01_Color.pdf PDF
Appendix_4.2_G-02-01_Color.pdf PDF
Appendix_4.2_g-05-01.pdf PDF
Attachment_2_PPI_Tool_Instructions_17_Feb_16.docx DOCX document
Appendix_4.2_C-01-01.pdf PDF
Appendix_4.2_C-05-01.pdf PDF
Appendix_4.4.xlsx XLSX spreadsheet
FA4814-16-R-0005.pdf PDF
Appendix_4.4_(Part_2).pdf PDF
Attachment_6_17_Feb_16.docx DOCX document
Attachment_1_17_Feb_16.docx DOCX document
Appendix_4.2_g-07-01.pdf PDF
Appendix_4.3.xls XLS spreadsheet
Appendix_4.6.pdf PDF
Attachment_4_Performance_Survey_Form_17_Feb_16.xlsx XLSX spreadsheet
Appendix_4.4.xlsx XLSX spreadsheet
Appendix_4.2_g-03-01.pdf PDF
Appendix_4.7.xlsx XLSX spreadsheet
Appendix_4.2_g-04-01_color.pdf PDF
Attachment_5_GFP_17_Feb_16.xlsx XLSX spreadsheet
Appendix_4.2_G-10-01.pdf PDF
Appendix_4.1.pdf PDF
Appendix_4.5.pdf PDF
Show all 47

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Attachment 3, Past Performance Summary Sheet (PPSS)

1. Contractor:

2. Applicable Solicitation Subfactor (environmental, O&M, etc.,):

3. PPSS # ():

4. Past Performance Requirement:

5. Past Performance Location:

6. Start Date:

7. Completion Date:

8. Client Organization:

9. Facility Owner Organization:

a. Facility Owner Point of Contact:

b. Facility Owner Phone Number:

c. Facility Owner email Address:

10. Acted as Prime Contractor? (Yes/No)

11. Past Performance Description (scope, manpower, equipment, management)

Attachment 3, Past Performance Summary Sheet (PPSS) (SAMPLE)

1. Contractor: Gemini LLC

2. Applicable Solicitation Subfactor (environmental, O&M, etc.,): Subfactor 2 O&M

3. PPSS # (F high voltage distribution):

A. Past Performance Requirement: 2 years of experience within the last 5 years of operations, maintenance, and minor repair of a high voltage electrical distribution system rate at over 5 megawatts. This will include a substation, overhead distribution, underground distribution, switching, transformers, and lighting.

4. Past Performance Location: Keflavik Naval Air station

5. Start Date: Sept 2011

6. Completion Date: Aug 2014

7. Client Organization: 57 FIS

a. Point of Contact: Lt CMDR John Doe

b. Facility Owner Phone Number: 01-327-988-0897

c. Facility Owner email Address: Doe.john.5@us.navy.mil

8. Acted as Prime Contractor? (Yes/No): Yes

9. Past Perfromance Description (scope, manpower, equipment, management):

Through a NAVFAC $1.8M annual contract we provided all operations, maintenance, and repair for a 7.5 megawatt diesel power plant and 13.8KV power distribution system. Components included: substation, switch gear, 34 transformers, over 4 miles of overhead distribution, 1.2 miles of underground distribution, and street lights covering 2.3 miles of roadway. Our 13 man contract team included generator operators and electricians qualified for both high and low voltage system maintenance and repairs. We employed two high reach trucks and provided all vehicles, equipment, materials and parts to keep the system operational, provide new services and disconnect old services no longer needed. System achieved a 99.99% reliability rate with only one major outage in the duration of our 3 year contract.

File details come from the government source that posted it. Updated .