This document contains questions and answers regarding a solicitation for a modular firing range. The solicitation is seeking proposals for the purchase and delivery of a modular firing range at Offutt Air Force Base to be used by the 55th Security Forces Squadron. Key details include that the solicitation has been set aside 100% for small businesses under NAICS code 32311 with a small business size standard of 750 employees. The purpose of the modular firing range is to provide live-fire and non-live fire training capabilities for security forces personnel. Proposers must be registered in the System for Award Management and plans and specifications for the range design shall be stamped by a Nebraska licensed engineer.

View the file

Other files for this federal contract opportunity

Other files attached to Modular Firing Range, newest first.
File Type Posted
40. FA4600-20-Q-0036-0013.pdf PDF
41. SOW - 10 Sep 20.pdf PDF
38. FA4600-20-Q-0036-0012.pdf PDF
39. SOW - 9 Sep 20.docx.pdf PDF
36. Questions and Answers Part VI.pdf PDF
35. FA4600-20-Q-0036-0011.pdf PDF
37. SOW - 08 Sep 20.pdf PDF
33. FA4600-20-Q-0036-0010.pdf PDF
34. SOW - 04 Sep 20.pdf PDF
31. FA4600-20-Q-0036-0009.pdf PDF
32. SOW - 02 Sep 20.pdf PDF
29. SOW - 28 Aug 20.pdf PDF
28. FA4600-20-Q-0036-0008.pdf PDF
30. Firing Range Electrical Requirements.pdf PDF
25. Questions and Answers Part V.pdf PDF
24. FA4600-20-Q-0036-0007.pdf PDF
26. SOW - 26 Aug 20.pdf PDF
27. Firing Range Electrical Requirements.pdf PDF
23. FA4600-20-Q-0036-0006.pdf PDF
22. SOW - 24 Aug 20.pdf PDF
20. FA4600-20-Q-0036-0005.pdf PDF
19. Amended 52.212-1.pdf PDF
17. Q&A_Part III.pdf PDF
16. FA4600-20-Q-0036-0004.pdf PDF
18. SOW - 20 Aug 20.pdf PDF
12. Q&A_Part II.pdf PDF
13. Lot 30 Historical Drawings Full Set.pdf PDF
15. Site Visit Contractor Sign-In Sheet.pdf PDF
11. Amended 52.212-1 and -2.pdf PDF
14. Modular Firing Range Orientation Graphic.pdf PDF
10. FA4600-20-Q-0036-0003.pdf PDF
8. Q&A - 1.pdf PDF
9. SOW - 13 Aug 20.docx.pdf PDF
7. FA4600-20-Q-0036-0002.pdf PDF
6. OAFB Face Covering Policy.pdf PDF
4. Amendment 1.docx DOCX document
3. FA4600-20-Q-0036-0001.pdf PDF
5. COVID Screening Questions.pdf PDF
2. UFC 4-179-02-2020.pdf PDF
1a. Division 1 - 01 33 00 Section 1B_1-31-2019.DOCX DOCX document
1b. Division 1 - 01 57 19 - 1C _July 2019.docx DOCX document
1. Offutt Modular Firing Range- SOW.docx DOCX document
1d.Lot 30 Firing Range.pdf PDF
1c. Division 0 - 00 10 00 Section 1AJuly 19.DOCX DOCX document
Combo RFQ.docx DOCX document
Show all 45

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Questions & Answers Part IV

Modular Firing Range

FA4600-20-Q-0036

1. Q: Range Control Booth Noise: In accordance with UFC 4-179-02 the maximum ambient noise levels in the Range Control Booth must be 60 dBA and the maximum live-fire noise levels (dBA) is at 85 dBA. Given the fact that this modular range is located approximately 0.4 mile south of Offutt’s runway, we need to understand what the existing ambient levels are when the base is fully operational.

a. The sound level requirements in the UFC are intended to apply to the internal operations of the range itself, specifically including weapons firing and machinery noise. External factors, such as aircraft operations, are not included or mentioned in the UFC.

2. Q: Are there any sound studies available to establish a baseline that states it is understood that the level is not above 60 dBA at that location?

a. Section 4-20.2 defines ambient noise as: “Ambient noise does not include the impulse noise generated by gunfire but does include other noise sources such as air handling and dust collection systems.” There are no sound studies available .

3. Q: Are we obligated to meet the levels as shown inside the Range Control Booth?

a. Yes, in accordance with UFC 4-179-02 and SOW Section 9.3.5.

4. Q: Will the government provide us with the necessary sound levels at the site since jet noises typically exceed the levels as shown? Additional design elements may need to be considered to meet this requirement.

a. Should aircraft operations happen to interfere with UFC required noise level testing, that test will be invalidated without penalty or negative action. The final range product must be compliant with UFC section 4-20 “Noise” and table 4-3., in accordance with SOW Section 9.3.5.

5. Q: Can the government assure the contractor that additional electrical capacity will be made available if required should the existing capacity be insufficient to meet the overall range operating requirements, including the minimum heating requirements of the solicitation and UFC-4-179-02?

a. There is sufficient power capacity in the vicinity of the site for up to 1000

KVA. This should be adequate, based upon initial market research, for a range and HVAC systems compliant with the SOW. SOW Section 6.2.2 has a point of contact at OPPD for information on transmission lines in the area.

6. Is the contractor required to be a state licensed modular building/range manufacturer, to ensure all required standards are being met?

a. No, the manufacturer does not have to be a state licensed manufacturer.

However, the range design plans and specifications shall be stamped by a

Nebraska licensed engineer, see updated SOW 24 Aug 20, Section 4.3.1.