Attachment_07_-Sample_Project_Drawing_M1-Layout1.pdf
PDF 128 KB Posted
- Attached to
- Simplified Acquisition Base Engineer Requirements (SABER) IDIQ Federal contract opportunity
- Solicitation number
- FA441719RA002
About this file
This document contains a sample project drawing and related federal contract opportunity notice. The project drawing depicts an HVAC plan for repair room 102 at an Air Force Special Operations Command facility, showing details of the packaged terminal heat pump unit, air flow rates, temperature and humidity setpoints, and control sequences.
The related contract opportunity is a Simplified Acquisition Base Engineer Requirements indefinite-delivery/indefinite-quantity contract to be awarded by the Department of the Air Force Special Operations Command at Hurlburt Field, Florida. The notice provides basic information about the opportunity but does not include details on required supplies or services, response dates, award amounts, or other salient terms.
Attachment 07
View the file
Other files for this federal contract opportunity
Show all 39
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-1
H V
A C
P L
A N
A
IR
F O
R C
E S
P E
C
IA
L O
P E
R A
T
IO
N S
C O
M M
A N
D
S O
C E
S H
U R
L B
U R
T F
IE
L
D , F
L O
R
ID
A
AS BUILT
R E
P A
IR
R
O O
M
, B
L D
G X
AutoCAD SHX Text
PTHP-1
AutoCAD SHX Text
OFFICE/
AutoCAD SHX Text
ADMIN.
AutoCAD SHX Text
AutoCAD SHX Text
SCALE: 1/4" = 1'-0"
AutoCAD SHX Text
%%UHVAC PLAN
AutoCAD SHX Text
AIR HANDLING UNIT
AutoCAD SHX Text
EXHAUST AIR LOUVER
AutoCAD SHX Text
AUXILIARY
AutoCAD SHX Text
DRY BULB
AutoCAD SHX Text
DEGREE FAHRENHEIT
AutoCAD SHX Text
ENTERING
AutoCAD SHX Text
FULL LOAD AMPS
AutoCAD SHX Text
FEET PER MINUTE
AutoCAD SHX Text
HORSE POWER
AutoCAD SHX Text
ELECTRIC
AutoCAD SHX Text
%%UMECHANICAL ABBREVIATIONS
AutoCAD SHX Text
CUBIC FEET PER MINUTE
AutoCAD SHX Text
EXTERNAL STATIC PRESSURE
AutoCAD SHX Text
COEFFICIENT OF PERFORMANCE
AutoCAD SHX Text
ENERGY EFFICIENCY RATIO
AutoCAD SHX Text
AHU
AutoCAD SHX Text
ESP
AutoCAD SHX Text
FPM
AutoCAD SHX Text
HP
AutoCAD SHX Text
FLA
AutoCAD SHX Text
EER
AutoCAD SHX Text
EAL
AutoCAD SHX Text
ENT
AutoCAD SHX Text
ELEC
AutoCAD SHX Text
DB
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
COP
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AUX
AutoCAD SHX Text
THOUSAND BRITISH THERMAL UNIT
AutoCAD SHX Text
HEAT PUMP CONDENSING UNIT
AutoCAD SHX Text
HOUR
AutoCAD SHX Text
HR
AutoCAD SHX Text
MBTU
AutoCAD SHX Text
T-AWAY
AutoCAD SHX Text
RLA
AutoCAD SHX Text
RUN LOAD AMPS
AutoCAD SHX Text
THROW AWAY
AutoCAD SHX Text
VELOCITY
AutoCAD SHX Text
WET BULB
AutoCAD SHX Text
VEL
AutoCAD SHX Text
WB
AutoCAD SHX Text
MANUAL VOLUME DAMPER
AutoCAD SHX Text
OUTSIDE AIR LOUVER
AutoCAD SHX Text
MAXIMUM
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
NUMBER
AutoCAD SHX Text
REFRIGERANT
AutoCAD SHX Text
NO.
AutoCAD SHX Text
REF
AutoCAD SHX Text
OAL
AutoCAD SHX Text
MVD
AutoCAD SHX Text
MAX
AutoCAD SHX Text
MIN
AutoCAD SHX Text
HZ
AutoCAD SHX Text
HERTZ
AutoCAD SHX Text
HPCU
AutoCAD SHX Text
AutoCAD SHX Text
MB
AutoCAD SHX Text
MB
AutoCAD SHX Text
SHEET NO.:
AutoCAD SHX Text
PROJECT NO.:
AutoCAD SHX Text
SHEET REF.:
AutoCAD SHX Text
BUILDING NO.:
AutoCAD SHX Text
DRAWN BY:
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text
DATE:
AutoCAD SHX Text
CIVIL ENGINEER
AutoCAD SHX Text
CHIEF ENGINEER
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
APPROVED
AutoCAD SHX Text
REV #
AutoCAD SHX Text
DATE
AutoCAD SHX Text
DESCRIPTION
AutoCAD SHX Text
APP'D
AutoCAD SHX Text
PERCENTAGE
AutoCAD SHX Text X
AutoCAD SHX Text
CONTENT
AutoCAD SHX Text
CONTENT
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text R
AutoCAD SHX Text C
AutoCAD SHX Text S
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text C
AutoCAD SHX Text I
AutoCAD SHX Text A
AutoCAD SHX Text A
AutoCAD SHX Text N
AutoCAD SHX Text N
AutoCAD SHX Text P
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text L
AutoCAD SHX Text O
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text M
AutoCAD SHX Text M
AutoCAD SHX Text S
AutoCAD SHX Text C
AutoCAD SHX Text O
AutoCAD SHX Text D
AutoCAD SHX Text
PETERSON ENGINEERING INC.
AutoCAD SHX Text
PENSACOLA, FLORIDA 32501
AutoCAD SHX Text
(PROF. ENG. #: 3600)
AutoCAD SHX Text
(850) 434-0513
AutoCAD SHX Text
75 SOUTH "F" STREET
AutoCAD SHX Text
PETER_JOB_NUM
AutoCAD SHX Text
22 NOV 2018
AutoCAD SHX Text
PHASE
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
MBTU/HR
AutoCAD SHX Text
AutoCAD SHX Text
AIR DATA
AutoCAD SHX Text
CFM
AutoCAD SHX Text
TOTAL
AutoCAD SHX Text
MARK
AutoCAD SHX Text
PTHP-1
AutoCAD SHX Text O.A.
AutoCAD SHX Text
CFM
AutoCAD SHX Text
AutoCAD SHX Text 47.0
AutoCAD SHX Text
AMBIENT
AutoCAD SHX Text
PACKAGE TERMINAL HEAT PUMP
AutoCAD SHX Text
COOLING DATA
AutoCAD SHX Text
ENT. DB
AutoCAD SHX Text 9.0
AutoCAD SHX Text 80.0
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
ENT. WB
AutoCAD SHX Text 67.0
AutoCAD SHX Text
%%DF
AutoCAD SHX Text
CAPACITY
AutoCAD SHX Text
MBTU/HR
AutoCAD SHX Text
AMBIENT
AutoCAD SHX Text 95.0
AutoCAD SHX Text
%%DF
AutoCAD SHX Text 8.4
AutoCAD SHX Text
HEATING DATA
AutoCAD SHX Text
COMPRESSOR
AutoCAD SHX Text
F.L.A. (AMPS)
AutoCAD SHX Text 11.5
AutoCAD SHX Text
SEER
AutoCAD SHX Text
MINIMUM
AutoCAD SHX Text
%%DF
AutoCAD SHX Text 3.6
AutoCAD SHX Text
VOLTS
AutoCAD SHX Text
HEAT (KW)
AutoCAD SHX Text 2.5
AutoCAD SHX Text
ELECTRICAL
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
HZ
AutoCAD SHX Text
REMARKS
AutoCAD SHX Text
AutoCAD SHX Text
FILTER
AutoCAD SHX Text SEQUENCE OF OPERATION WHEN ROOM TEMPERATURE RISES ABOVE THE COOLING SET POINT THE INDOOR UNIT FAN, THE OUTDOOR UNIT REVERSING VALVE AND DX COOLING SHALL BE CYCLED AS NEEDED TO SATISFY SPACE COOLING REQUIREMENTS. WHEN ROOM TEMPERATURE FALLS BELOW THE HEATING SET POINT THE INDOOR UNIT FAN, THE OUTDOOR UNIT REVERSING VALVE AND ONE STAGE OF COMPRESSOR HEAT SHALL BE CYCLED AS NEEDED TO SATISFY SPACE HEATING REQUIREMENTS. IF OUTSIDE AIR TEMPERATURE IS BELOW 35°F AND COMPRESSOR HEAT IS INSUFFICIENT TO SATISFY SPACE HEATING DEMAND THE ELECTRIC AUXILIARY HEAT SHALL CYCLE ON. WHEN THE OUTDOOR UNITDEFROST CIRCUIT IS ACTIVATED THE AUXILIARY HEAT SHALL CYCLE AS NEEDED TO PREVENT OVERCOOLING THE SPACE. WHEN ROOM HUMIDITY RISES ABOVE SET POINT THE HEAT PUMP DX COOLING SHALL BE ACTIVATED AND THE ELECTRIC HEAT SHALL BE CYCLED ON AS NEEDED TO MAINTAIN ROOM TEMPERATURE. THE OUTSIDE AIR DAMPER IS CONTROLLED BY A TIMECLOCK. UPON ACTIVATION OF THE SMOKE DETECTOR THE AHU SHALL SHUT DOWN AND SIGNAL THE FIRE ALARM SYSTEM.
AutoCAD SHX Text
DAMPER
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
AIR
AutoCAD SHX Text
OUTSIDE AIR
AutoCAD SHX Text
AUTOMATIC
AutoCAD SHX Text
RETURN
AutoCAD SHX Text
OUTDOOR UNIT
AutoCAD SHX Text
COMPRESSOR 1
AutoCAD SHX Text
DEFROST
AutoCAD SHX Text
CHANGEOVER
AutoCAD SHX Text
%%UTYPICAL HEAT PUMP UNIT CONTROL
AutoCAD SHX Text
COIL
AutoCAD SHX Text
DX
AutoCAD SHX Text
FAN
AutoCAD SHX Text
MS
AutoCAD SHX Text
ELECTRIC
AutoCAD SHX Text
STRIP HEATER
AutoCAD SHX Text
SMOKE
AutoCAD SHX Text
DETECTOR
AutoCAD SHX Text
7 DAY PROGRAMMABLE
AutoCAD SHX Text
SUPPLY AIR
AutoCAD SHX Text
THERMOSTAT
AutoCAD SHX Text
HUMIDISTAT
AutoCAD SHX Text
TIME CLOCK
AutoCAD SHX Text
RH
AutoCAD SHX Text
FIRE ALARM SHUTDOWN
| Sheets and Views |
| Layout1 |