This document contains details of a pre-solicitation notice for a Simplified Acquisition of Base Engineering Requirements contract opportunity. The Department of the Air Force intends to issue an indefinite delivery indefinite quantity contract for construction services at Joint Base Andrews and Joint Base Anacostia Bolling, with a magnitude between $100 million and $250 million. Services will include carpentry, road and parking repairs, roofing, excavation, electrical, plumbing and other construction tasks. The solicitation is designated as an 8(a) competitive set-aside for SBA 8(a) firms located in the Mid-Atlantic region. Interested firms must show evidence of bonding capability up to $1 million for single projects and an aggregate total of $30 million. The anticipated solicitation posting date is January 27, 2020 on SAM.gov. The contract will have a five-year base period and two one-year options, with a minimum guarantee of $2,000. Evaluation criteria will consider technical acceptability, past performance, and price.
View the file
Other files
Show all 42
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Attachment 25 SEED Project Monaco Annunciator Panel Pictures (7) Fire Alarm Inspection Record for B- 3285
::::t ........ --·--. --., -·
Fire Alarm Inspection Record for B- 3285
INSPECTION/TESTING/PREVENTATIVE MAINTENANCE REPORT FORM
TIME: 1200 DATE: 10-11-19
MEM Contracting, Inc.
3608 Patrick Ave. Bldg. #: 3285
Joint Base Andrews, MD 20762 Address: NAVY BUILDING
Representative: B. Hoerr/F. Lujan Bldg. P.O.C.: Clifford.minor.1@us.af.mil
Telephone #: Telephone #: 240-857-6651
MONITORING ENTITY APPROVING AGENCY
Contact: AAF FD Contact:
Telephone: 301-981-4986 Telephone:
TYPE TRANSMISSION SERVICE
Telephone Lines Weekly
Radio Transmitter Monthly
McCullough Quarterly
Digital Semi-Annually
Multiplex Annually
Control Unit Fire Lite Model # 424A
Circuit Style 6 Number of Circuits 2 zones
Software Rev
Last Date System Was Serviced
Last Date Software/Configuration Revised
ALARM-INITIATING DEVICES/CIRCUIT INFORMATION
Quantity Circuit Style
6 Manual Fire Alarm Boxes
Ion Smoke Detectors
Photo Smoke Detectors
Duct Smoke Detectors
6 Heat Detectors
Water-flow Switches
Supervisory Switches
Other:
ALARM NOTIFICATION APPLIANCES/CIRCUIT INFORMATION
Quantity Circuit Style
See Device List Bells
See Device List Horns
See Device List Strobes
See Device List Z Horn/Strobes
See Device List Chimes
See Device List Speakers
See Device List Other:
Number of Alarm Notification Circuits: 1
Number of N.A.C. Panels: 0
Are Circuits Monitored for Integrity? Yes No
SUPERVISORY SIGNAL-INITIATING DEVICES/CIRCUIT INFORMATION
Quantity Circuit Style
Fire Pump Power
Fire Pump Running
Fire Pump Auto Position
Fire Pump/Controller Trouble
Valve Tamper Trouble
Low Air Pressure
Generator Running
Other:
SIGNALING LINE CIRCUITS
Quantity Style(s)
SYSTEM POWER SUPPLIES
A. Primary (Main): Nominal Volts 120v Amps 20amp.
Over-current Protection: Type DTK Amps 20amp.
Location (Primary Supply Power) Mech closet
B. Secondary (Standby)
2 -12v Storage Battery: Amp Hours 7AHR.
TYPE OF BATTERY
Dry Cell
Nickel-Cadmium
Sealed Lead-Acid
Lead Acid
Gel-Cell
Other: 12.99v/12.90v 6.2ah
PRIOR TO ANY TESTING
NOTIFICATIONS ARE MADE Yes No Who Time
Monitoring Entity AFD 1200
Building Occupants Personnel 1200
Building P.O.C
Other:
AHJ (Notified) If Problems
SYSTEM TESTS AND INSPECTION
TYPE Visual Functional Comments
Control Unit (S)
Interface Equip. Monaco # 297
Lamps/L.E.D.’s 12.98v 5.9ah
Fuses
Primary Power Sup
Trouble Signals
Disc. Switch
Ground Faults
SECONDARY POWER
TYPE Visual Functional Comments
Battery Condition
Load Voltage
Discharge Test
Charger Test
Specific Gravity
Surge Suppressor
Remote Annunciator
NOTIFICATION APPLIANCES
TYPE Visual Functional Comments
Audible
Visual
Speaker
Voice Clarity
EMRGENCY COMMUNICATION EQUIPMENT
TYPE Visual Functional Comments
Phone Set
Phone Jacks
Off Hook Lamp
Amplifiers
Tone Generator
Call In Signal
System Performance
INTERFACE EQUIPMENT Visual Operation Simulation
Specify Monaco
Specify
SPECIAL HAZARD SYSTEM
Specify
Specify
Special Procedures:
Comments:
SUPERVISING STATION MONITORING
TYPE Yes No Time Comments
Alarm Signal 1020 10-11-19
Alarm Restoration 1021
Trouble Signal 1025
Supervisory Signal
Supervisory Restoration
NOTIFICATION THAT TEST IS COMPLETE
Notified Yes No Who Time
Building P.O.C
Monitoring Entity AFD 1300
Building Occupants Personnel 1300
SEE ATTACHED DISCREPANCIES SHEET FOR LIST OF ITEMS.
System Restored To Normal Operation: Date 10-11-19 Time 1300
THIS TESTING WAS PERFORMED IN ACCORDANCE WITH APPLICABLE NFPA
STANDARDS.
Name of Inspector(s): Bill Hoerr / Fernando Lujan Date: 10-11-19 Time: 1300
Bldg. Name: Navy Building Polygraph Bldg. # 3285 Date: 10-11-19
# Device Location Visual ZONE/ADDRESS Pass Fail
1. P South entrance Z-1
2. HD South part of building Z-2
3. HD South part of building Z-2
4. HD South part of building Z-2
5. HD South part of building Z-2
6. P North exit Z-1
7. H-ST hallway
8. HD South part of building Z-2
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
26.
27.
28.
29.
30.
31.
32.
33.
P - Pull Station WF - Water-flow TS - Valve Tamper PS - Pressure Switch SD - Smoke Detector HD - Heat Detector
DD - Duct Detector GD - Gas Detector B - Bell ST-Strobe H - Horn S – Speaker A - Abort SV - Solenoid Valve
DC - Door Closure
Comments: