Exhibit C--Chiloquin Fitness Center Expansion--Bid Set Drawings--2026-09-05.pdf
PDF 23 MB Posted
- Solicitation number
- S-Q10089-00017928
- Issued by
- Jackson County, Cheshire CDP, Oregon
About this file
This is a permit set of architectural and engineering drawings for a fitness center expansion project in Chiloquin, Oregon, involving Klamath Tribal Health and the Klamath Tribes. The project encompasses a 20,319 square foot addition to an existing 15,152 square foot fitness center, bringing the total building area to 35,471 square feet. The expansion includes new spaces for fitness studios, workout areas, wellness services, locker rooms, restrooms, administrative offices, and support facilities. The drawings are dated September 4, 2026, and reflect a single-story, Type V-B construction classified under both Business (Group B) and Assembly (Group A-3) occupancies. The project is designed for a total occupant load of 493 individuals and includes comprehensive fire protection systems, accessibility features compliant with ADA standards, and energy efficiency measures per Oregon codes. The building site is located at 320 Chiloquin Boulevard in Chiloquin, Oregon, on an 8.22-acre parcel.
The architectural, structural, mechanical, electrical, and plumbing design teams have been assembled with Steele Associates Architects serving as the lead architect, supported by specialized consultants including AKS Engineering and Forestry (civil), Froelich Engineers (structural), CEA Consulting Engineers (mechanical, electrical, and plumbing), and Wallace Group (geotechnical). Construction is planned to comply with 2025 Oregon Structural, Mechanical, and Fire Codes, 2023 Oregon Electrical and Plumbing Codes, and 2024 Oregon Energy Efficiency standards. The project requires a general building permit and establishes requirements for fire sprinkler systems, manual fire alarm systems for the 493-person occupancy, emergency lighting and exit signage, ADA accessibility accommodations throughout, and proper separation between occupancy groups with a 2-hour fire wall required between the A-3 and B occupancies. No specific funding amounts, pricing information, or contract award details are contained within these technical drawings.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AHJ STAMP COPYRIGHT 2026
STEELE ASSOCIATES ARCHITECTS
All rights reserved. Reproduction or use in any form or by any means- graphic, electronic, mechanical, etc.- without written permission of STEELE ASSOCIATES ARCHITECTS is unlawful and subject to criminal prosecution.
AS
SO
C
IA
TE
S
AR
C
H
IT
EC
TS
L
LC
N W
P O
TT
S
C T.
S U
IT
E
BE
N
D , O
R
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
NOT FOR
CONSTRUCTIO
N
5 4 3 2 1
5 4 3 2 16
B
C
D
E
B
C
D
E
AA
9/ 4/
:3
6:
P M
G001
CTLG
17127.02
PE
R
M
IT
S
ET
C O
VE
R
S H
EE
T
COVER SHEET
09.04.2026
C H
IL
O
Q U
IN
B
LV
D
KL
AM
AT
H
T R
IB
ES
F
IT
N
ES
S C
EN
TE
R A
D D
IT
IO
N
KLAMATH TRIBES FITNESS CENTER
ADDITION
PERMIT SET
09/04/2026
C H
IL
O
Q U
IN
O
R
EG
O N
GENERAL
G001 COVER SHEET
G002 GENERAL NOTES LEGENDS ABBREVIATIONS
G003 CODE PLAN
G004 ADA REQUIREMENTS
G005 ADA REQUIREMENTS
G006 CODE SUMMARY
CIVIL
C001 GENERAL CIVIL NOTES AND LEGEND
C010 EXISTING CONDITIONS AND DEMOLITION PLAN
C101 PRELIMINARY EROSION AND SEDIMENT CONTROL PLAN
C201 PRILIMINARY CIVIL SITE PLAN
C301 PRELIMINARY GRADING, DRAINAGE AND STORMWATER PLAN
C401 DETAILS
C402 DETAILS
ARCHITECTURE
AS101 ARCHITECTURAL SITE PLAN
AD101 DEMOLITION PLAN AND REFLECT CEILING PLAN
A010 ASSEMBLY TYPES
A110 DIMENSION PLAN
A111 FLOOR PLAN
A120 REFLECTED CEILING PLAN
A130 ROOF PLAN
A200 EXTERIOR ELEVATIONS
A300 BUILDING SECTIONS
A310 WALL SECTIONS
A311 WALL SECTIONS
A312 WALL SECTIONS
A400 ENLARGED PLANS
A401 ENLARGED PLANS - RESTROOMS
A410 INTERIOR ELEVATIONS
A500 WALL DETAILS
A520 ROOF & CANOPY DETAILS
A530 CEILING DETAILS
A580 DOOR DETAILS
A590 WINDOW DETAILS
A601 DOOR AND WINDOW SCHEDULE & LEGEND
INTERIOR DESIGN
ID101 FINISH SCHEDULE
ID102 LEVEL 1 - FINISH PLAN
STRUCTURAL
S000 COVER SHEET
S001 GENERAL STRUCTURAL NOTES
S002 GENERAL STRUCTURAL NOTES
S003 SPECIAL INSPECTION
S004 SCHEDULES
S101 FOUNDATION PLAN
S140 ROOF FRAMING PLAN
S501 FOUNDATION DETAILS
S502 FOUNDATION DETAILS
S701 ROOF FRAMING DETAILS
S702 ROOF FRAMING DETAILS
S801 STANDARD SHEAR WALL
PLUMBING
P001 SCHEDULES & NOTES
P100 FIRST FLOOR PLAN - SANITARY
P200 FIRST FLOOR PLAN - DOMESTIC
MECHANICAL
M001 SCHEDULES & NOTES
M100 FIRST FLOOR PLAN
M101 ROOF PLAN
ELECTRICAL
E001 ELECTRICAL LEGEND AND SCHEDULES
E101 LIGHTING PLAN
E201 POWER PLAN
E202 ROOF POWER PLAN
E301 SYSTEMS PLAN
E401 ELECTRICAL RISER DIAGRAM
E501 ELECTRICAL PANEL SCHEDULES
E601 ELECTRICAL DETAILS
E602 ELECTRICAL DETAILS
DRAWING INDEX
Contact:
Phone:
Email:
Architect Steele Associates Architects, LLC
Chris Thome
(503) 363-9867 cthome@steele-arch.com
2738 NW Potts Court, Suite 110 Bend, OR 97703
Contact:
Phone:
Email:
Client Klamath Tribal Health
Jerry Mellentine
(541) 882-1487 gamellentine@klamathtribalhealth.org
3949 South Sixth Street Klamath Falls, OR 97603
Contact:
Phone:
Email:
Civil Engineer AKS Engineering & Forestry, LLC
Jon Page
(541) 317-8429 pagej@aks-eng.com
2777 NW Lolo Dr., Ste 150 Bend, OR 97703
VICINITY MAP
PROJECT RENDERING
PROJECT DESCRIPTION:
DELEGATED DESIGN:
TAX MAP LOCATION/DESCRIPTION: Klamth County Tax Map 340734CC / Tax Lot 200
LOT SIZE: 8.22 ACRES
GROSS AREA: 9885.35 SF
SINGLE STORY - B / A3 OCCUPANCY FITNESS CENTER
FIRE SPRINKLER & ALARM
REDBUILT TRUSS DESIGN
LANDSCAPE AND IRRIGATION
Contact:
Phone:
Email:
Structural Engineer Froelich Engineers
Michael Peterson
(541) 383-1828 mpeterson@froelich-engineers.com
745 NW Mt. Washington Drive, Suite 204 Bend, OR 97703
Contact:
Phone:
Email:
Mechanical Engineer CEA Consulting Engineers
Ethan Mansfield
(541) 318-0404 ethanm@cea-engineering.com
1345 NW Wall, Suite 101 Bend, OR 97701
Contact:
Phone:
Email:
Electrical Engineer CEA Consulting Engineers
Kennedy Davidson
(541) 318-0404 kennedy@cea-engineering.com
1345 NW Wall, Suite 101 Bend, OR, 97701
PROJECT TEAM
PROJECT LOCATION
Contact:
Phone:
Email:
Plumbing Engineer CEA Consulting Engineers
Ethan Mansfield
(541) 318-0404 ethanm@cea-engineering.com
1345 NW Wall, Suite 101 Bend, OR, 97701
Contact:
Phone:
Email:
Geotechnical Engineer Wallace Group, Inc.
Adam Larson
(541) 280-5439 alarson@wallacegroup-inc.com
62915 NE 18th Street, Suite 1 Bend, OR, 97701
REV. DATE DESCRIPTION
CL
DRAWING NUMBER
DRAWING NAME
DRAWING SCALE
AA WINDOW/CURTAIN WALL DESIGNATION. SEE WINDOW SCHEDULE.
A101
A9
A
A9
A
DATUM TAGREVISION CLOUD & TAG
REVISION CLOUD
AROUND AREA OF
CHANGE
DELTA SYMBOL &
REVISION NUMBER
A101
? KEYNOTE.
A101
GRID HEAD
GLAZING DESIGNATION.
GLAZING MODIFIER
202A DOOR DESIGNATION. SEE DOOR SCHEDULE
FM9
WALL, FLOOR, CEILING, ROOF DESIGNATION. SEE APPROPRIATE TYPE
SHEETS.
WALL, FLOOR, BASE, CEILING FINISH TAG. THIS SYMBOL WHEN
ATTACHED TO A WALL SHALL INDICATE THIS FINISH FOR ENTIRE
LENGTH OF WALL FROM ONE INTERSECTION TO THE NEXT AND
NOT BE TERMINATED BY WINDOWS OR DOORS UNO.
Room name
ROOM NAME TAG
Ø
CENTER LINE
NUMBER
DEGREE
AND
AT
WORK POINT OR ELEV. BENCH MARK
DIAMETER OR ROUND
NORTH ARROW
SYMBOLS
DETAIL TAGS
DETAIL NUMBER
PAGE WHERE FOUND
DETAIL CUT LINE
DETAILED AREA
WALL SECTION TAG
WALL SECTION NUMBER
PAGE WHERE FOUND
WALL SECTION CUT LINE
BUILDING SECTION TAG
WALL SECTION NUMBER
PAGE WHERE FOUND
WALL SECTION CUT LINE
DRAWING TITLE
ELEVATION TAGS
PAGE
VIEW
ROOM FINISH TAG
FLOOR FINISH
CORRESPONDING
WALL FINISHES
BASE FINISH
MISCELLANEOUS KEYED NOTE SYMBOLS
ROOM NAME
ROOM NUMBER
ELEVATION DATUM
INDICATES ITEM OR
FLOOR LEVEL BEING
REFERENCED
A101
NAME
ELEVATION
NW
SW
EWWWFF BF
A101
1 View Name 1/8" = 1'-0"
AA
METAL
EARTH
CONCRETE
CONCRETE
MASONRY UNIT
FINISHED WOOD MEMBER
PLYWOOD
BATT INSULATION
GYP. BOARD
CONTINUOUS WOOD
MEMBER
WOOD BLOCKING
PLASTER OR STUCCO
RIGID INSULATION
MINERAL WOOL
INSULATION
ALUMINUM
GRAVEL
STONE
METAL OR WOOD STUD FRAMED WALL
• WALL TYPE DESIGNATES WIDTH OF
WALL
• WIDTH OF WALL DIMENSIONED ONLY AT
1/4"=1' OR LARGER SCALE
• DOORS DIMENSIONED TO WIDTH OF
NOMINAL OPENING
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
METAL OR WOOD STUD FRAMED WALL W/
MASONRY OR STONE VENEER
• WIDTH OF WALL DIMENSIONED FROM
FACE OF MASONRY.
• WIDTH OF MASONRY WALL
DIMENSIONED FROM FACE OF STUD.
• DOORS DIMENSIONED TO WIDTH OF
NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
MASONRY WALL
• WIDTH OF WALL DIMENSIONED TO
NOMINAL SIZE.
• DOORS DIMENSIONED TO
CENTERLINE OF NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT MASONRY
OPENING.
CONCRETE WALL
• ACTUAL WIDTH OF WALL DIMENSIONED
• DOORS DIMENSIONED TO CENTERLINE
OF NOMINAL OPENING.
• WINDOWS DIMENSIONED TO NOMINAL
FRAME SIZE - NOT ROUGH OPENING.
NEW CONSTRUCTION AT EXISTING
NEW CONSTRUCTION SHOWN HATCHED W/ THICKER LINE.
ALL EXISTING COMPONENTS SHOWN THIN LINE SOLID, NO HATCH.
ALL EXISTING COMPONENTS SHOWN THIN LINE SOLID, NO HATCH.
ALL COMPONENTS TO BE DEMOLISHED ARE SHOWN DASHED, THICK LINE.
EXISTING
METAL OR WOOD STUD FRAMED WALL.
• WIDTH OF WALL DIMENSIONED
TO FINISHED FACE.
• DOORS DIMENSIONED TO
NOMINAL DOOR SIZE
EXCLUDING FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
EXISTING
METAL OR WOOD STUD FRAMED WALL
W/ MASONRY OR STONE VENEER
• WIDTH OF WALL DIMENSIONED
FROM FINISHED FACE TO
OVERALL NOMINAL WIDTH.
• DOORS DIMENSIONED TO
NOMINAL DOOR SIZE EXCLUDING
FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
EXISTING
MASONRY WALL (TO REMAIN)
• WIDTH OF WALL DIMENSIONED
TO NOMINAL SIZE.
• DOORS DIMENSIONED TO
NOMINAL DOOR SIZE
EXCLUDING FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
EXISTING
CONCRETE WALL (TO REMAIN)
• NOMINAL WIDTH OF WALL
DIMENSIONED.
• DOORS DIMENSIONED TO
NOMINAL DOOR SIZE EXCLUDING
FRAME.
• WINDOWS DIMENSIONED TO
NOMINAL FRAME SIZE.
NEW CONSTRUCTION EXISTING CONDITIONS
ALL NEW CONSTRUCTION IS SHOWN HATCHED & SHADED AS ILLUSTRATED BELOW.
ALL NEW CONSTRUCTION IS FULLY NOTED AS SHOWN BELOW.
ALL WORK IS NEW UNLESS LABELED "EXISTING"
ALL EXISTING CONSTRUCTION IS SHOWN WITHOUT HATCH AS ILLUSTRATED BELOW.
ALL EXISTING CONSTRUCTION IS LABELED "EXISTING" BY KEYNOTE OR OTHERWISE.
ALL DIMENSIONS TO EXISTING ARE APPROXIMATE ONLY AND ARE TO BE FIELD
VERIFIED BY THE CONTRACTOR.
S T
R U
C T
U R
E
T O
P O
F
9A
4'-0"
G R
ID
T O
G R
ID
T O
4'-0"
9A
4'-0"
(DEMOLISH
EXISTING)
(EXISTING TO
REMAIN)
4'-0"
4'-0"
4M
3B
5J
± 3'-0"
/4
/2
/8
4'-0" ±
1 2
3 2
3 2
4'-0" ±
4'-0" ±
3 2
3 2
OF STRUCTURE
RIGHT SIDE
AHJ STAMP COPYRIGHT 2026
STEELE ASSOCIATES ARCHITECTS
All rights reserved. Reproduction or use in any form or by any means- graphic, electronic, mechanical, etc.- without written permission of STEELE ASSOCIATES ARCHITECTS is unlawful and subject to criminal prosecution.
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
N
W P
O T
T S
C T
S
U
IT
E
B E
N D
O
R
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
5 4 3 2 16
B
C
D
E
B
C
D
E
AA
/4
/2
:3
:0
P
M
G002
CTLG
17127.02
P E
R M
IT
S
E T
G E
N E
R A
L N
O T
E S
L E
G E
N D
S A
B B
R E
V
IA
T
IO
N S
GENERAL NOTES
LEGENDS
ABBREVIATIONS
09.04.2026
C H
IL
O
Q U
IN
B
L V
D
K L
A M
A T
H T
R
IB
E S
F
IT
N E
S S
C E
N T
E R
A D
D
IT
IO
N
C H
IL
O
Q U
IN
O
R E
G O
N
NEW MATERIALS LEGEND (TYPICAL SECTION VIEWS)
SYMBOLS GENERAL NOTES:ABBREVIATIONS:
DIMENSIONING LEGEND (TYPICAL PLAN VIEWS)
ABBREV ABBREVIATION (S)
ABB ABBREVIATION (S)
A.F.F. ABOVE FINISHED FLOOR
AD ACCESS DOOR
ACOUS ACOUSTICAL
A/C AIR CONDITIONING
ALUM ALUMINUM
AB ANCHOR BOLT
APPR APPROVED
AC ASPHALT CONCRETE
BM BEAM
BLK BLOCK
BD BOARD
BOT BOTTOM
B.O.B. BOTTOM OF BEAM
BLDG BUILDING
CLG CEILING
CH CEILING HEIGHT
CEM CEMENT
C/C CENTER TO CENTER
CER CERAMIC
CLR CLEAR
CLOS CLOSET
COL COLUMN
COMPO COMPOSITION
CONC CONCRETE
CMU CONCRETE MASONRY UNIT
CONN CONNECTION
CONT CONTINUOUS
CORD COORDINATE
CORR CORRIDOR
CSK COUNTERSINK
DEL DELETE
DET DETAIL
DIAG DIAGONAL
DIA DIAMETER
DIM DIMENSION
DIR DIRECTION
DR DOOR
DO DOOR OPENING
DBL DOUBLE
DF DOUGLAS FIR
DN DOWN
DS DOWNSPOUT
DWG DRAWING
DF DRINKING FOUNTAIN
EA EACH
EWC ELECTRIC WATER COOLER
ELEC ELECTRICAL
ELEV OR EL ELEVATION
ELEV ELEVATOR
EQ EQUAL
EQUIP EQUIPMENT
EXIST EXISTING
EJ EXPANSION JOINT
EXT EXTERIOR
FOC FACE OF CONCRETE
FOS FACE OF STUD
FOW FACE OF WALL
FT FEET
FRP FIBER REINFORCED
PLASTIC
FIN FINISH
FF FINISH FLOOR
FO FINISHED OPENING
FHC FIRE HOSE CABINET
FLR FLOOR
FD FLOOR DRAIN
FS FLOOR SINK
FDN FOUNDATION
REF FREFERENCE
FH FULL HEIGHT
FS FULL SIZE
FSD FULL SIZE DETAIL
GALV OR GV GALVANIZED
GSM GALVANIZED SHEET METAL
GA GAUGE
GC GENERAL CONTRACTOR
GL GLASS
GFRC GLASS FIBER REINFORCED
CONCRETE
GR GRADE
GYP. BD. GYPSUM BOARD
HDWD HARDWOOD
H HIGH
HP HIGH POINT
HM HOLLOW METAL
HORIZ HORIZONTAL
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JAN JANITOR
LAV LAVATORY
LEV LEVEL
LTWT LIGHT WEIGHT
LTG LIGHTING
MAINT MAINTENANCE
MFG MANUFACTURER
MO MASONRY OPENING
MAT'L MATERIAL
MAX MAXIMUM
MECH MECHANICAL
MB MECHANICAL BOLT
MET METAL
MEZZ MEZZANINE
MIN MINIMUM
MISC MISCELLANEOUS
MULL MULLION
(N) NEW
NR NON-RATED
N.I.C. NOT IN CONTRACT
N.T.S. NOT TO SCALE
NO. NUMBER
OFF OFFICE
OC ON CENTER
OPN'G OPENING
OCC OPERATOR CONTROL
CENTER
OPP OPPOSITE
OH OPPOSITE HAND
OD OUTSIDE DIAMETER
OF OVERFLOW
OFI OWNER FURNISH ITEM
OFOI OWNER FURNISHED OWNER
INSTALLED
PR PAIR
PLAS PLASTIC
PL PLATE
PLWD PLYWOOD
PC PORTLAND CEMENT
PREP PREPARATION
PT PRESSURE TREATED
PTDF PRESSURE TREATED
DOUGLAS FIR
PROJ PROJECTION
QT QUARRY TILE
R OR RAD RADIUS
REDW'D REDWOOD
REFL REFLECTED
REINF REINFORCE
REQ'D REQUIRED
RES RESILIENT
RR RESTROOM(S)
R RISER
RD ROOF DRAIN
RTU ROOF TOP UNIT
RM ROOM
R.O. ROUGH OPENING
SECT SECTION
SHT SHEET
SIM SIMILAR
SPECS SPECIFICATIONS
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STA STATION
STL STEEL
STG STORAGE
STRUCT STRUCTURAL
SIMUL SUMULATED
SUSP SUSPENDED
SYM SYMMETRICAL
TEL TELEPHONE
TEMP TEMPERED
THK THICK
T&G TONGUE & GROOVE
TBC TOP BACK OF CURB
T.O.C. TOP OF CONCRETE OR
CURB
T.O.F TOP OF FOOTING
T.O.P. TOP OF PARAPET
T.O.S. TOP OF STEEL
T.O.W. TOP OF WALL
TDC TRAFFIC DECK COVERING
T TREAD
TYP TYPICAL
UNO UNLESS NOTED OTHERWISE
V.I.F. VERIFY IN FIELD
VER VERTICAL
WC WATER CLOSET
WL WATER LEVEL
WP WATERPROOFING
W WIDE
W/ WITH
WD WOOD
WP WORKING POINT
WI WROUGHT IRON
A THE GENERAL CONTRACTOR SHALL HEREAFTER BE REFERRED TO AS
GENERAL CONTRACTOR OR "GC". THE OWNER MAY HEREAFTER BE REFERRED
TO AS "OWNER".
B PLEASE NOTE:THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK
REGARDLESS OF THE LOCATION OF THE INFORMATION IN THE DOCUMENTS.
THE GENERAL CONTRACTOR SHALL UTILIZE THE CONSTRUCTION DRAWINGS
AND WRITTEN SPECIFICATIONS FOR ALL REQUIRED INFORMATION TO PROVIDE
COMPLETE CONSTRUCTION OF THIS PROJECT. ITEMS LISTED IN DRAWINGS
MAY NOT BE INCLUDED IN SPECIFICATIONS. ITEMS LISTED IN SPECIFICATIONS
MAY NOT BE INCLUDED IN DRAWINGS.
C GC SHALL BE RESPONSIBLE FOR COORDINATING WORK BETWEEN TRADES.
D UNLESS OTHERWISE INDICATED IN THE CONSTRUCTION DOCUMENTS AS BEING
NOT IN CONTRACT (N.I.C.) OR EXISTING, ALL ITEMS, MATERIALS AND
INSTALLATION OF SAME ARE PART OF THE CONTRACT AS DEFINED BY THE
CONSTRUCTION DOCUMENTS. THE GC SHALL PROVIDE AND INSTALL ALL
ACCESSORIES, COMPONENTS AND ASSEMBLIES REQUIRED FOR THE WORK
DEPICTED OR SPECIFIED.
E THE INDIVIDUAL DISCIPLINE DRAWINGS (A, C, E, ETC.) ARE PART OF A LARGER
SET OF DRAWINGS, WHICH, WHEN COMPLETE, CONSISTS OF DRAWINGS LISTED
IN THE "DRAWING INDEX." PARTIAL SETS OF DRAWINGS NOT INCLUSIVE OF ALL
DISCIPLINES ARE INCOMPLETE AND SHOULD NOT BE DISTRIBUTED OR
UTILIZED.
F CONSTRUCTION DOCUMENTS CONSIST OF DRAWINGS AND SPECIFICATIONS.
CONTRACTOR AND SUBCONTRACTORS SHALL CAREFULLY REVIEW ALL
DRAWINGS AND SPECIFICATIONS IN THIS PROJECT AND BECOME FAMILIAR
WITH ALL STRUCTURES, FIXTURES AND EQUIPMENT TO BE INSTALLED.
COORDINATE ALL ASPECTS OF THE CONSTRUCTION WITH ALL TRADES ON THE
JOB TO ENSURE THAT ALL MATERIALS AND LABOR REQUIRED TO PROVIDE A
COMPLETE AND OPERATIONAL FACILITY ARE INCLUDED IN THE BID.
G THE GC SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO
BEGINNING ANY WORK AND SHALL BE RESPONSIBLE FOR ALL WORK AND
MATERIALS INCLUDING THOSE FURNISHED BY SUBCONTRACTORS. THE GC
SHALL ACCEPT PREMISES AS FOUND. OWNER WILL MAINTAIN THE EXISTING
CONDITION OF THE SITE AND EXISTING STRUCTURES AT THE TIME OF BIDDING.
H THE GC AND SUB-CONTRACTORS SHALL CAREFULLY REVIEW THE
ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL, PLUMBING, CIVIL
AND LANDSCAPE AND OTHER PROJECT RELATED DOCUMENTS PRIOR TO
CONSTRUCTION.
I DISCREPANCIES BETWEEN PORTIONS OF THE CONTRACT DOCUMENTS ARE
NOT INTENDED. THE GENERAL CONTRACTOR IS TO CLARIFY WITH THE
ARCHITECT ANY SUCH DISCREPANCIES PRIOR TO COMMENCING WORK.
J DIMENSIONS TAKE PRECEDENCE OVER DRAWINGS: DO NOT SCALE DRAWINGS
TO DETERMINE ANY LOCATIONS. THE ARCHITECT SHALL BE NOTIFIED OF ANY
DISCREPANCY PRIOR TO CONTINUING WITH WORK.
K WHERE A DETAIL CALL OUT DESCRIBES A TYPE OF CONDITION, IT APPLIES TO
ALL SIMILAR CONDITIONS, WHETHER OR NOT AT DETAIL TAG IS SHOWN AT THAT
LOCATION ON THE PLANS.
L ALL PLAN DIMENSIONS ARE FROM GRIDLINE OR FACE OF STUD OR FACE OF
BLOCK UNLESS OTHERWISE INDICATED. SEE SECTION ON "DIMENSIONING" THIS
SHEET.
M DIMENSIONS INDICATED TO BE "CLEAR" OR "CLR." ARE DIMENSIONS TO THE
FINISHED SURFACE OF THE WALL OR ASSEMBLY.
N THE GC SHALL REPORT TO THE ARCHITECT ALL CONDITIONS REQUIRING
COORDINATION/ CHANGES WITH THE CONTRACT DOCUMENTS. COORDINATION
/ APPROVAL SHALL TAKE PLACE BEFORE THE WORK BEGINS. ALL CHANGES TO
THE CONTRACT COST SHALL BE APPROVED THROUGH A CHANGE ORDER.
O DETAILED DRAWINGS AND LARGER SCALE DRAWINGS TAKE PRECEDENCE
OVER SMALL SCALE DRAWINGS.
P THE ARCHITECT WILL REVIEW SHOP DRAWINGS AND SAMPLES FOR
CONFORMANCE WITH DESIGN CONCEPT OF THE PROJECT. THE ARCHITECT'S
REVIEW OF A SEPARATE ITEM SHALL NOT INDICATE APPROVAL OF AN
ASSEMBLY IN WHICH THE ITEM FUNCTIONS. THE ARCHITECT WILL NOT REVIEW
SHOP DRAWINGS UNTIL THE GC HAS REVIEWED AND STAMPED THE SHOP
DRAWING/SUBMITTAL. THE GC IS RESPONSIBLE FOR FIELD VERIFYING ALL
DIMENSIONS SHOWN ON THE SHOP DRAWINGS. THE ARCHITECT'S REVIEW OF
THE SHOP DRAWINGS SHALL NOT OVERRIDE THE CONDITIONS DESCRIBED IN
THE CONTRACT DOCUMENTS UNLESS SPECIFICALLY NOTED OTHERWISE BY
THE ARCHITECT.
Q FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S
STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA SHEETS IN
ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
R FOR GRADING, TRENCHING ETC., CONTACT THE ARCHITECT FOR
INSTRUCTIONS PRIOR TO THE CONTINUATION OF WORK SHOULD ANY UNUSUAL
CONDITIONS BECOME APPARENT DURING GRADING OR FOUNDATION
CONSTRUCTION. EXISTING ELEVATIONS AND LOCATIONS TO BE JOINED SHALL
BE VERIFIED BY THE GENERAL CONTRACTOR BEFORE CONSTRUCTION.
S ALL WORK, MATERIALS AND METHODS SHALL BE IN CONFORMANCE WITH THE
CODES, ORDINANCES AND REGULATIONS OF ALL GOVERNMENTAL AGENCIES
HAVING JURISDICTION AT THE PROJECT LOCATION. THE GENERAL
CONTRACTOR MUST COMPLY WITH THE CONTRACTOR REGISTRATION
REQUIREMENTS OF ALL GOVERNING AUTHORITIES.
T ALL PROJECT CONSTRUCTION SHALL CONFORM WITH ANSI A-117.1-2010, AND
THE AMERICANS WITH DISABILITIES ACT (ADA). THE MORE STRINGENT SHALL
APPLY.
U THE GC SHALL NOTIFY ALL APPLICABLE LOCAL GOVERNING AUTHORITIES AND
UTILITIES PRIOR TO COVERING UP ANY WORK REQUIRING INSPECTION.
V THE GC SHALL MAINTAIN ALL REQUIRED EXITS AND FIRE LANES IN WORKING
ORDER.
W A GENERAL BUILDING PERMIT IS REQUIRED. ALL OTHER PERMITS OR
CONNECTION FEES SHALL BE SECURED BY THE GENERAL CONTRACTOR AND
REIMBURSED THROUGH THE OWNER.
X THE GC SHALL PROVIDE AND INSTALL FIRE EXTINGUISHERS WHERE SHOWN ON
PLAN.
Y MINIMUM FLAME SPREAD CLASSIFICATION OF INTERIOR FINISH SHALL
CONFORM TO THE BUILDING CODE AND LOCAL GOVERNING BUILDING
CODES/ORDINANCES. SEE CODE SUMMARY, SHEET G0.30.
Z THE GC SHALL PROVIDE AND IS SOLELY RESPONSIBLE AND LIABLE FOR PUBLIC
AND EMPLOYEE PROTECTION AS NECESSARY AND AS REQUIRED BY THE
CODES, INCLUDING EXTERIOR AND INTERIOR PEDESTRIAN TRAFFIC BARRIERS.
ALL WORK SHALL CONFORM TO THE ORDINANCES AND REGULATIONS OF
GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT.
AA THE GC SHALL PROVIDE TEMPORARY BARRICADES FOR DUST AND NOISE
CONTROL, AND ALL REQUIRED ENVIRONMENTAL PROTECTION WHERE WORK
JOINS EXISTING CONDITIONS.
BB ALL DEBRIS SHALL BE REMOVED FROM PREMISES AND ALL AREAS SHALL BE
LEFT IN A CLEAN (BROOM) CONDITION DAILY.
CC GC SHALL PREPARE AND IMPLEMENT AN INDOOR AIR QUALITY PROGRAM TO BE
INSTITUTED DURING CONSTRUCTION ACTIVITIES.
DD GC SHALL PREPARE AND IMPLEMENT A CONSTRUCTION WASTE MANAGEMENT
AND RECYCLING PLAN, TO BE PROVIDED TO THE OWNER.
EE GC SHALL AVOID UNNECESSARY DISRUPTIONS TO THE FUNCTIONS AND/OR
DAILY ACTIVITIES OF ADJACENT EXISTING SUITES AND BUILDINGS.
FF CALL BEFORE YOU DIG! OREGON LAW REQUIRES THE GENERAL CONTRACTOR
TO CONTACT THE "OREGON UTILITY NOTIFICATION CENTER" AT 1 (800) 332-2344
OR 1 (503) 232-1987, NO LESS THAN TWO (2) BUSINESS DAYS, BUT NO MORE
THAN TEN (10) BUSINESS DAYS BEFORE COMMENCING ANY EXCAVATION.
LOCATE ALL UNDERGROUND UTILITIES BEFORE STARTING ANY BELOW GRADE
WORK. THE GENERAL CONTRACTOR SHALL BEAR ALL EXPENSE OF REPAIR OR
REPLACEMENT OF IDENTIFIED UTILITIES OR OTHER PROPERTY DAMAGED BY
OPERATIONS IN CONJUNCTION WITH THE EXECUTION OF THE WORK.
GG PRIOR TO CONSTRUCTION, THE GENERAL CONTRACTOR SHALL BE
RESPONSIBLE FOR NOTIFYING THE ARCHITECT OF ANY EXISTING DAMAGE TO
THE NEIGHBORING SUITES, NEW OR EXISTING SITE IMPROVEMENTS, ETC.
FAILURE TO DO SO SHALL PLACE THE GENERAL CONTRACTOR WITH THE SOLE
RESPONSIBILITY FOR CORRECTING SUCH DAMAGE.
HH APPROVED PLANS SHALL BE KEPT IN A PLAN BOX AND SHALL NOT BE USED BY
WORKMEN. ALL CONSTRUCTION SETS SHALL REFLECT THE SAME
INFORMATION. THE GENERAL CONTRACTOR SHALL ALSO MAINTAIN, IN GOOD
CONDITION, ONE COMPLETE SET OF PLANS WITH ALL REVISIONS, ADDENDA
AND CHANGE ORDERS, ON THE PREMISES AT ALL TIMES. THESE ARE TO BE
KEPT UNDER THE CARE OF THE JOB SUPERINTENDENT.
II THE GC IS TO PROVIDE BLOCKING AS REQUIRED FOR MOUNTING OF WALL
MOUNTED SHELVES, CABINETS, HC GRAB BARS AND PARTITION BRACES AND
ALL OTHER ITEMS IDENTIFIED ON THE EQUIPMENT OR ACCESSORY SCHEDULE.
BLOCKING SHALL BE FIRE TREATED WHERE REQUIRED BY THE BUILDING CODE.
JJ THE GC IS RESPONSIBLE FOR RECEIVING, UNLOADING, UNCRATING,
INSTALLATION AND HOOK-UP OF ALL OWNER FURNISHED ITEMS UNLESS NOTED
OTHERWISE ON THE DRAWINGS.
KK THE GC IS TO ASSURE THAT NO REBAR OR REINFORCEMENT IS PRESENT
PRIOR TO CORE DRILLING OR PLACING BOLTS OR ANY OTHER ITEM WHICH
COULD DISTURB THE STRUCTURAL SLAB OR FOUNDATION WALLS.
LL PROVIDE GALVANIC PROTECTION BETWEEN DISSIMILAR MATERIALS WHERE
REQUIRED.
MM PROVIDE METAL TRIM OR CASING AT ALL EDGES OF PLASTER AND DRYWALL
SURFACES WHERE IT TERMINATES OR MEETS ANY OTHER MATERIAL, UNLESS
NOTED OTHERWISE.
NN PROVIDE METAL CORNER TRIM AT ALL OUTSIDE CORNERS OF PLASTER AND
DRYWALL SURFACES.
OO ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED
WITH APPROPRIATE SEALANT MATERIAL.
PP UNLESS OTHERWISE NOTED, ALL EXTERIOR AND INTERIOR METAL, TRIM,
TREILLAGE, RAILINGS, MOLDINGS, FRAMES, CASTING ETC., SHALL BE PAINTED.
QQ FIXTURES AND EQUIPMENT SHOWN ARE FOR COORDINATION PURPOSES ONLY.
REFER TO THE MANUFACTURER'S PRODUCT DATA AND THE MECHANICAL
AND/OR ELECTRICAL DRAWINGS AND SPECIFICATIONS FOR FIXTURE AND
EQUIPMENT DESCRIPTIONS, LOCATIONS AND INSTALLATION REQUIREMENTS.
RR THE GC SHALL VERIFY LOCATIONS OF ALL CEILING ACCESS PANELS WITH
MECHANICAL, FIRE SPRINKLER AND PLUMBING PLANS. ACCESS PANELS SHALL
BE FURNISHED AND INSTALLED WITH A FIRE RATING EQUAL TO THE WALL OR
CEILING ASSEMBLY INTO WHICH THEY ARE TO BE INSTALLED. FINISH AND
LOCATION SHALL BE APPROVED BY THE ARCHITECT.
SS THE GC SHALL VERIFY DIMENSIONS OF ALL EQUIPMENT PADS & BASES WITH
EQUIPMENT MANUFACTURERS & SHALL VERIFY ALL SIZES AND LOCATIONS OF
DUCT OPENINGS ON ROOF AND INTERIOR SHAFTS.
TT SYSTEMS SHOWN ON THE DRAWINGS ARE INTENDED TO BE FINISHED,
INSTALLED AND TURNED OVER TO THE OWNER IN PROPER FUNCTIONING
CONDITION. ALL WORK IS TO BE CONSIDERED IN CONTRACT SUM.
UU WHERE DAMAGE TO INSTALLED FINISHES OCCURS DURING CONSTRUCTION,
THE CONTRACTOR SHALL RESTORE SUCH FINISHES AS SPECIFIED OR
SCHEDULED, TO MATCH ADJACENT SURFACES.
VV CUTTING AND PATCHING: WHETHER OR NOT SHOWN ON THE DRAWINGS, THE
CONTRACTOR SHALL DO ALL CUTTING, FITTING, OR PATCHING OF WORK THAT
MAY BE REQUIRED TO MAKE ITS SEVERAL PARTS FIT TOGETHER PROPERLY
AND SHALL NOT ENDANGER ANY IN-PLACE WORK BY CUTTING, EXCAVATING OR
OTHERWISE ALTERING THE WORK OR ANY PART OF IT. ALL PATCHING,
REPAIRING AND REPLACING OF MATERIALS AND SURFACES CUT OR DAMAGED
IN EXECUTION OF THE WORK SHALL BE REPLACED WITH APPLICABLE
MATERIALS SO THAT SURFACES WILL, UPON COMPLETION, MATCH
SURROUNDING SIMILAR SURFACES IN FIT, FINISH AND COLOR.
AREA LEGEND
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM
ASSEMBLY W/O FIXED SEATS - UNCONCENTRATED
BUSINESS AREAS
EXERCISE ROOM
161 SF
B. OCC.
2 OCC.
HEALTH ASSESS.
76 SF
ACCESSORY
1 OCC.
KITCHEN STORAGE
92 SF
B. OCC.
1 OCC.
RED LIGHT
115 SF
B. OCC.
1 OCC.
MASSAGE
116 SF
B. OCC.
1 OCC.
CHIRO OFFICE
814 SF
B. OCC.
6 OCC.
TEACHING KITCHEN
174 SF
B. OCC.
2 OCC.
SMOOTHIE CAFE
84 SF
B. OCC.
1 OCC.
SHOWER
83 SF
B. OCC.
1 OCC.
SHOWER
68 SF
B. OCC.
1 OCC.
ADA RR
66 SF
B. OCC.
1 OCC.
ADA RR
65 SF
B. OCC.
1 OCC.
ADA RR
67 SF
B. OCC.
1 OCC.
ADA RR
201 SF
B. OCC.
2 OCC.
SAUNA / COLD PLUNGE
82 SF
ACCESSORY
1 OCC.
STORAGE
184 SF
B. OCC.
2 OCC.
PHYSICAL THERAPY
447 SF
4 OCC.
LOUNGE
103 SF
B. OCC.
1 OCC.
REGISTERED DIETITIAN OFFICE
99 SF
B. OCC.
1 OCC.
OFFICE
99 SF
B. OCC.
1 OCC.
OFFICE
97 SF
B. OCC.
1 OCC.
OFFICE
291 SF
ACCESSORY
1 OCC.
STUDIO STORAGE
1,154 SF
A-3
24 OCC.
FITNESS STUDIO
544 SF
ACCESSORY
2 OCC.
COMMUNITY ROOM STORAGE
4,421 SF
A-3
89 OCC.
MAIN WORKOUT SPACE
250 SF
B. OCC.
2 OCC.
TRAINERS
4,625 SF
A-3, UNCONCENTRATED
309 OCC.
COMMUNITY ROOM
248 SF
B. OCC.
2 OCC.
VESTIBULE
444 SF
ACCESSORY
2 OCC.
FITNESS STORAGE
693 SF
B OCC.
5 OCC.
LOBBY
212 SF
B OCC.
2 OCC.
WOMEN'S RR
214 SF
B OCC.
2 OCC.
MEN'S RR
477 SF
ACCESSORY
2 OCC.
MECH
427 SF
B. OCC.
3 OCC.
HALL
192 SF
ACCESSORY
2 OCC.
FACILITY STORAGE
94 SF
B. OCC.
1 OCC.
FACILITY MANAGER OFFICE
95 SF
B. OCC.
1 OCC.
I.T. OFFICE
134 SF
B. OCC.
1 OCC.
I.T.
357 SF
B. OCC.
3 OCC.
WELLNESS
1,270 SF
HALL
B U
IL
D
IN
G
D
IA
G O
N A L
D
IS
T A N
C E : 2
' 8
E X
IT
S
E P
A R
A T
IO
N
D I S
T A
N C
E : 1
T.D. = 194' 10"
T .D
T.D. = 74' 8"
T .D
GENERAL NOTES:
A. SEE SHEET G002 FOR GENERAL NOTES, LEGENDS, AND ABBREVIATIONS.
B. SEE TITLE SHEET FOR DRAWING INDEX.
C. DO NOT SCALE DRAWINGS.
D. CONTRACTOR / SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS BEFORE BEGINNING WORK, AND SHALL REPORT TO THE
ARCHITECT ANY ERRORS, INCONSISTENCIES OR OMISSIONS BEFORE
BEGINNING WORK. SEE GENERAL NOTES AND SPECIFICATIONS.
1 HR FIRE PARTITIONS
2 HR FIREWALL
TRAVEL DISTANCE
AHJ STAMP COPYRIGHT 2026
STEELE ASSOCIATES ARCHITECTS
All rights reserved. Reproduction or use in any form or by any means- graphic, electronic, mechanical, etc.- without written permission of STEELE ASSOCIATES ARCHITECTS is unlawful and subject to criminal prosecution.
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
N
W P
O T
T S
C T
S
U
IT
E
B E
N D
O
R
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
5 4 3 2 16
B
C
D
E
B
C
D
E
AA
/4
/2
:3
:0
P
M
G003
CTLG
17127.02
P E
R M
IT
S
E T
C O
D E
P L A
N
CODE PLAN
09.04.2026
C H
IL
O
Q U
IN
B
L V
D
K L
A M
A T
H T
R
IB
E S
F
IT
N E
S S
C E
N T
E R
A D
D
IT
IO
N
C H
IL
O
Q U
IN
O
R E
G O
N
1/8" = 1'-0"
E6 LEVEL 1 - OCCUPANCY DIAGRAM
LEGEND:
SCALE : 1/8" = 1'-0"
0' 4' 8' 16' 24'2'
OCCUPANCY CALCULATION
NUMBER NAME FUNCTION OF SPACE AREA
FLOOR AREA
SF PER
OCCUPANT OCCUPANTS
ACCESSORY STORAGE AREAS, MECHANICAL EQUIPMENT ROOM
116 KITCHEN
STORAGE
ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
76 SF 300 SF 1
114 STORAGE ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
82 SF 300 SF 1
133 STUDIO
STORAGE
ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
291 SF 300 SF 1
129 COMMUNITY
ROOM
STORAGE
ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
544 SF 300 SF 2
102 FITNESS
STORAGE
ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
444 SF 300 SF 2
105 MECH ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
477 SF 300 SF 2
133 FACILITY
STORAGE
ACCESSORY STORAGE
AREAS, MECHANICAL
EQUIPMENT ROOM
192 SF 300 SF 1
ASSEMBLY W/O FIXED SEATS - UNCONCENTRATED
108 COMMUNITY
ROOM
ASSEMBLY W/O FIXED
SEATS -
UNCONCENTRATED
4,625 SF 15 SF 309
BUSINESS AREAS
120 HEALTH
ASSESS.
BUSINESS AREAS 161 SF 150 SF 2
113 RED LIGHT BUSINESS AREAS 92 SF 150 SF 1
110 MASSAGE BUSINESS AREAS 115 SF 150 SF 1
109 CHIRO OFFICE BUSINESS AREAS 116 SF 150 SF 1
119 TEACHING
KITCHEN
BUSINESS AREAS 814 SF 150 SF 6
125 SMOOTHIE
CAFE
BUSINESS AREAS 174 SF 150 SF 2
126 SHOWER BUSINESS AREAS 84 SF 150 SF 1
127 SHOWER BUSINESS AREAS 83 SF 150 SF 1
122 ADA RR BUSINESS AREAS 68 SF 150 SF 1
121 ADA RR BUSINESS AREAS 66 SF 150 SF 1
117 ADA RR BUSINESS AREAS 65 SF 150 SF 1
118 ADA RR BUSINESS AREAS 67 SF 150 SF 1
115 SAUNA / COLD
PLUNGE
BUSINESS AREAS 201 SF 150 SF 2
112 PHYSICAL
THERAPY
BUSINESS AREAS 184 SF 150 SF 2
124 LOUNGE BUSINESS AREAS 447 SF 150 SF 3
128 REGISTERED
DIETITIAN
OFFICE
BUSINESS AREAS 103 SF 150 SF 1
112 OFFICE BUSINESS AREAS 99 SF 150 SF 1
131 OFFICE BUSINESS AREAS 99 SF 150 SF 1
132 OFFICE BUSINESS AREAS 97 SF 150 SF 1
106 TRAINERS BUSINESS AREAS 250 SF 150 SF 2
101 VESTIBULE BUSINESS AREAS 248 SF 150 SF 2
100 LOBBY BUSINESS AREAS 693 SF 150 SF 5
103 WOMEN'S RR BUSINESS AREAS 212 SF 150 SF 2
104 MEN'S RR BUSINESS AREAS 214 SF 150 SF 2
169 HALL BUSINESS AREAS 427 SF 150 SF 3
134 FACILITY
MANAGER
OFFICE
BUSINESS AREAS 94 SF 150 SF 1
136 I.T. OFFICE BUSINESS AREAS 95 SF 150 SF 1
137 I.T. BUSINESS AREAS 134 SF 150 SF 1
111 WELLNESS BUSINESS AREAS 357 SF 150 SF 3
123 HALL BUSINESS AREAS 1,270 SF 150 SF 9
HALL BUSINESS AREAS Not Placed 150 SF
EXERCISE ROOM
130 FITNESS
STUDIO
EXERCISE ROOM 1,154 SF 50 SF 24
107 MAIN
WORKOUT
SPACE
EXERCISE ROOM 4,421 SF 50 SF 89
M
IN
M
IN
M A
X
B.O. REFLECTIVE SURFACE
MIRROR *PROVIDE PIPE
INSULATION AT ALL
EXPOSED PIPES.
O R
C O
U N
TE
R
S U
R
FA
C E
M A
X . T
.O . R
IM
8" MIN.
6" MAX
LAVATORY SIDE VIEW DASHED LINE INDICATED
DIMENSIONAL CLEARANCE OF UNDER FIXTURE
ENCLOSURE, IF REQUIRED.
MIRROR *PROVIDE PIPE
INSULATION AT ALL
EXPOSED PIPES.
8" MIN.
6" MAX
CHILDRENS LAVATORY SIDE VIEW DASHED LINE
INDICATED DIMENSIONAL CLEARANCE OF UNDER
FIXTURE ENCLOSURE, IF REQUIRED.
M
IN
T O
W A
LL
M
IN
19" MAX
52" MIN.
CL
CLEAR
FLOOR
SPACE
LAVATORY PLAN VIEW
M A
X
T O
O P
E R
A B
LE
P
A R
TS
M A
X
DIAPER CHANGING
STATION
CONTROLS & OPERATING MECHANISMS
FORWARD REACH
M A
X
IF
IN
S
TA
LL
E D
W /O
C A
B
IN
E T
O R
S
IN
K B
E
LO
W
M A
X
M
IN
CL
T O
E C
LE
A
R A
N C
E 9"
M
IN
O R
C O
U N
TE
R
S U
R
FA
C E
M A
X . T
.O . R
IM
M
IN
T O
E C
LE
A
R A
N C
E 9"
M
IN
60" MIN
M
IN
CL
ACCESSIBLE TOILET COMPARTMENT CLEARANCES AND MOUNTING HEIGHTS
890-940
35"-37"
M
IN
M
IN
AMBULATORY ACCESSIBLE
TOILET COMPARTMENT
CL
405-455
16"-18"
ACCESSIBLE WATER
CLOSET
430-485 17"-19"
AMBULATORY
ACCESSIBLE WATER
CLOSET
8" MIN
PARTITION
M
IN
8" MIN
PARTITION
M
IN
ELEVATION
ADULT
ELEVATION
CHILDREN
8" MIN
8" M
IN
PLAN
WHEELCHAIR ACCESSIBLE TOILET COMPARTMENT TOE
CLEARANCE
60" MIN.
405-455 16"-18"
M
IN
CL
TOILET PAPER
DISPENSER
7" -9
4" M
A X
M
IN
32" MIN.
4" MAX. 1420
56" MIN.
ALTERNATE DOOR
LOCATION
WALL-HUNG FIXTURE
WHEEL CHAIR ACCESSIBLE
TOILET STALL PLAN VIEW
0-
0-
6" MAX
36" MIN
CL
DISPENSER
LOCATION
42" MIN305
12" MAX
DISPENSER OUTLET LOCATION
(BELOW GRAB BAR)
0-
M
IN
0-
M
IN
0-
WATER CLOSET FRONT
VIEW
WATER CLOSET SIDE
VIEW
24" MIN
42" MAX
DISPENSER OUTLET
LOCATION (RECESSED)
M
IN
WATER CLOSET SIDE
VIEW
M A
X
24" MIN
42" MAX
1/ 2"
M
IN
WATER CLOSET SIDE
VIEW
24" MIN
36" MAX
M
IN
36" MAX
SIZE OF CLEARANCE
FOR WATER CLOSET
T.O. SEAT
405-455
16" -8"
42" MIN.
54" MIN.
DISPENSER OUTLET LOCATION
(BELOW GRAB BAR)
M
IN
DISPENSER OUTLET LOCATION DISPENSER IN
FRONT OF WATER CLOSET - EXEMPTION
M A
X
CL
180-230
7"-9"
60" MIN.
405-455 16"-18"
M
IN
CL
TOILET PAPER
DISPENSER
4" M
A X
M
IN
32" MIN.
4" MAX. 1420
56" MIN.
ALTERNATE DOOR
LOCATION
FLOOR-MOUNTED FIXTURE
WHEEL CHAIR ACCESSIBLE
TOILET STALL PLAN VIEW
GRAB BARS
32-51 1 1/4"-2"
CIRCULAR
NON-CIRCULAR
PERIMETER
4"-4.8"
100-120
2" MAX
1-1/2".
1-
1/ 2"
M
IN
M
IN
M
IN
60" MIN.
ALTERNATE WHEELCHAIR
TOILET COMPARTMENT
7" -9
5-
0-
6" MAX
36" MIN
CL
42" MIN305
12" MAX
DISPENSER OUTLET
LOCATION
0-
M
IN
5-
M
IN
5-
WATER CLOSET SIDE
VIEW - CHILDREN'S
1-
1/ 2"
M
IN
T.O. SEAT
305-455
12"-18"
42" MIN.
54" MIN.
WATER CLOSET FRONT
VIEW - CHILDREN'S
M A
X
CL
180-230
7"-9"
865-915
34"-36"
990-1040
39"-41"
13 1/2" MIN
M A
X
WALL HUNG TYPE
13 1/2" MIN
M A
X
STALL TYPE
URINAL FRONT
VIEW
HEIGHT AND DEPTH OF URINALS
M
IN
52" MIN.
CLEAR
FLOOR
SPACE
URINAL PLAN
VIEW
M
IN
M A
X
15" MAX
CL
CONTROL
WALLCONTROL
END WALL
TRANSFER TYPE SHOWER
COMPARTMENT CONTROL LOCATION
AND GRAB BAR MOUNTING HEIGHTS
BATHTUB CONTROL
LOCATION
27" MAX
M A
X SIDE
WALL
TRANSFER
(ELEVATION)
ALT. ROLL-IN (ELEVATION)
15" MAX. FROM SEAT CENTER LINE
M A
X
M A
X
CAN BE LOCATED ON
ANY WALL OF SHOWER
WITHOUT SEAT
ROLL-IN (ELEVATION)
CONTROL
WALL
27" MAX
M A
X
0-
5-
8" -1
0"
0-
BATHTUBS WITH REMOVABLE
IN-TUB SEATS
BATHTUBS WITH PERMANENT
SEATS
0-
0-
5-
8" -1
0"
C
LR
36" CLR.
18"
BACK WALL
SEAT
WALL
CONTROL
WALL
TRANSFER TYPE SHOWER
COMPARTMENT SIZE AND CLEARANCE W/
GRAB BARS
52" MIN.
M
IN
380-405 15"-16"
2 1/2" MAX
5-
1/
2" M
A X
560-585 22"-23"
3"
M A
X
SEAT
WALL
L-SHAPED RECTANGULAR
COMPARTMENT
ENTRY
1/ 2"
M A
X
380-405 15"-16"
3"
M A
X
2 1/2" MAX
LENGTH OF BATHTUB
M
IN
M
IN
12" MAX
24" MIN.
24" MAX
HEAD
END
WALL
CONTROL
END WALL
BATHTUBS WITH REMOVABLE IN TUB
SEAT
BATHTUBS WITH PERMANENT SEAT
AT HEAD END OF TUB
M
IN
15" MAX
12" MAX
M
IN
CONTROL
END WALL
BACK WALL
LENGTH OF BATHTUB
12" MIN.
HEAD
END
WALL
60" MIN. ENTRANCE
M
IN
. C
LR
M
IN
6" M
A X
6" MAX
CONTROL WALL
SEAT
WALL
SIDE
WALL
60" MIN.
6" MAX
6" M
A X
6" MAX
END
WALL
BACK WALL
END
WALL
SEAT
WALL
STANDARD ROLL-IN TYPE SHOWER
COMPARTMENT SIZE AND CLEARANCE
W/ GRAB BARS
ALTERNATE ROLL-IN TYPE SHOWER
COMPARTMENT SIZE AND CLEARANCE W/
GRAB BARS
ROLL-IN TYPE SHOWERBATHTUBS TRANSFER TYPE SHOWER
SHOWER SEATS
CL
4" M
A X
-1
3"
-6
M
IN
M
IN
-1
3"
-6
4" M
A X
4" M
A X
CL
36" MIN. ENTRANCE
16" MIN.
M
IN
M
IN
16" MIN.
BACK
WALL
M
IN
380-405
15"-16"
15" MIN.
610-915
24"-36"
4" M
A X
BACK WALL
36" MIN. ENTRANCE
0-
-1
3"
-6
M
IN
M
IN
-1
3"
-6
0-
C
LR
36" CLR.
18"
BACK WALL
SEAT
WALL
CONTROL
WALL
48" MIN.
M
IN
36" MIN. ENTRANCE
4" M
A X
TRANSFER TYPE SHOWER
EXISTING BUILDING
C
LR
36" CLR.
18"
BACK WALL
SEAT
WALL
CONTROL
WALL
TRANSFER TYPE SHOWER
COMPARTMENT SIZE AND CLEARANCE W/
GRAB BARS
52" MIN.
M
IN
36" MIN. ENTRANCE
4" M
A X
OR
4" MAX.
27" MAX
M A
XSIDE
WALL
M
IN
16" MIN.
6" M
IN
5" MAX
15" MIN.
PLAN VIEW
8" MIN. 6" MAX
M
IN
M
IN
T O
S P
O U
T
- 4 3"
STANDING USE ELEVATION HEIGHTS
EQUIPMENT
PERMITTED IN SHADED
AREA
8" MIN. 6" MAX
9" M
IN
M
IN
T O
S P
O U
T
M A
X
ADA ELEVATION HEIGHTS
EQUIPMENT
PERMITTED IN SHADED
AREA
DRINKING FOUNTAIN CLEARANCES
8" MIN.
6" MAX
9" M
IN
M
IN
T O
S P
O U
T
M A
X
EQUIPMENT
PERMITTED IN
SHADED AREA
ADA CHILDRENS ELEVATION HEIGHTS
17"-19"
FOR SINGLE
32" CLEAR
M
IN
. 31
M
IN
24" MAX
18" MIN.
M A
X
6" MIN.
6" MAX
RECESSED FOUNTAINS
1. RECESSED FOUNTAINS:
WITHIN ALCOVES MINIMUM 63" WIDE, MINIMUM 18" DEEP WHEN DOUBLE
DRINKING FOUNTAINS ARE REQUIRED AND 32" MIN. CLR. WHEN A SINGLE
FOUNTAIN IS PERMITTED.
A. CONTRACTOR SHALL COORDINATE WITH SIZE OF WATER FOUNTAIN TO
BE USED AND SIZE ALCOVE ACCORDINGLY COMPLYING WITH
REQUIREMENTS AND RECOMMENDATIONS AND COORDINATING WITH THE
ARCHITECT.
2. PROJECTED FOUNTAINS:
WARNING FOR THE VISION IMPAIRED AT A PROJECTED DRINKING FOUNTAIN CAN
BE PROVIDED BY EITHER OF THE FOLLOWING MEANS:
A. THE SURFACE OF THE FLOOR OR GROUND AT THE DRINKING FOUNTAIN
CAN BE OF CONTRASTING COLOR WITH A TEXTURE THAT CONTRASTS IN
RESILIENCY WITH THE ADJACENT FINISHED FLOOR MATERIAL, SO THAT IT
CAN BE SENSED BY A CANE, WITH THE TEXTURE EXTENDING FROM THE
WALL TO ONE FOOT BEYOND THE FRONT EDGE OF THE DRINKING
FOUNTAIN AND ONE FOOT BEYOND EACH SIDE OF THE FOUNTAIN, OR
INSTALL WING WALLS ON EACH SIDE OF THE DRINKING FOUNTAIN TO B.
PROJECT OUT FROM THE MAIN WALL AT LEAST AS FAR AS THE DRINKING
FOUNTAIN AND TO WITHIN 6" OF THE PATH OF TRAVEL FLOOR FINISH.
THERE MUST BE 32" CLEAR BETWEEN THE WING WALLS.
NOTE:
ILLUSTRATIONS SHOWN HERE ARE FOR DIMENSIONAL ACCESSIBILITY PURPOSES ONLY.
A SECOND DRINKING FOUNTAIN SHOULD BE PROVIDED AT A MOUNTING HEIGHT
SUITABLE TO PERSONS WITH LIMITED PHYSICAL BENDING ABILITY, ADJACENT TO THE
ACCESSIBLE FOUNTAIN, MAINTAINING MINIMUM CLEARANCES NOTED AND AS REQUIRED.
PROVIDE TEXTURED AREA OF CONTRASTING COLOR TO IDENTIFY WATER FOUNTAIN
LOCATION AS NOTED. WHEN FOUNTAIN IS AT AN INTERIOR LOCATION, THE TEXTURED
AREA SHALL ALSO BE OF DIFFERENT RESILIENCY THAN THAT OF THE ADJACENT FLOOR
SURFACE FINISH. SEE TYPICAL ACCESSIBILITY NOTES SHEET FOR ADDITIONAL
REQUIREMENTS.
M A
X
FO
R
C H
IL
D
R E
N
1/2" MAX
DOMINANT DIRECTION OF TRAVEL
LONG DIMENSION
PERPENDICULAR TO DOMINANT
DIRECTION OF TRAVEL
CHANGE-IN
DIRECTION
STRAIGHT
M
IN
. C
LR
A T
LE
A
S T
A S
W
ID
E A
S R
A M
P R
U N
60" MIN
BE 30 INCHES
NOTE: MAX RISE SHALL
60" MIN
60" MIN
M
IN
LANDING
RAMP RUN
SLOPE: 1:20 MIN. - 1:12 MAX.
LANDING
LANDING
R A
M P
R U
N
MAX CROSS SLOPE: 1:48
12" MIN.
12" MIN
12" MIN.
1 1/2" MIN
1- 1/
2" M
IN
TYPICAL HANDRAILS AT STAIRS TYPICAL HANDRAILS AT RAMPS
HORIZONTAL PROJECTIONS BELOW
GRIPPING SURFACE
HANDRAIL CLEARANCE
M A
X
A B
O V
E S
TA
IR
N O
S
IN
G
M A
X
EQ.EQ.
HANDRAIL CROSS SECTION
32-51 1 1/4"-2"
CIRCULAR
NON-CIRCULAR
NON-CIRCULAR
PERIMETER
4"-6 1/4" 100-160
2 1/4" MAX
AHJ STAMP COPYRIGHT 2026
STEELE ASSOCIATES ARCHITECTS
All rights reserved. Reproduction or use in any form or by any means- graphic, electronic, mechanical, etc.- without written permission of STEELE ASSOCIATES ARCHITECTS is unlawful and subject to criminal prosecution.
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
N
W P
O T
T S
C T
S
U
IT
E
B E
N D
O
R
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
5 4 3 2 16
B
C
D
E
B
C
D
E
AA
/4
/2
:3
:0
P
M
G004
CTLG
17127.02
P E
R M
IT
S
E T
A D
A R
E Q
U
IR
E M
E N
T S
ADA REQUIREMENTS
09.04.2026
C H
IL
O
Q U
IN
B
L V
D
K L
A M
A T
H T
R
IB
E S
F
IT
N E
S S
C E
N T
E R
A D
D
IT
IO
N
C H
IL
O
Q U
IN
O
R E
G O
N
GENERAL NOTES:
• REFER TO DOOR HARDWARE SPECIFICATIONS FOR DOOR HARDWARE ADA
REQUIREMENTS AND STANDARDS.
• REFER TO ELECTRICAL DRAWINGS FOR ELECTRICAL DEVICES ADA MOUNTING
HEIGHT REQUIREMENTS.
• REFER TO SITE PLAN FOR ACCESSIBLE ROUTE REQUIREMENTS AND DETAIL
REFERENCES. (NOT APPLICABLE TO ALL PROJECTS.)
• UNLESS NOTED AS "MIN." OR "MAX" DIMENSIONS SHOWN ARE ABSOLUTE.
DIMENSIONS SHOWN HERE SHALL GOVERN THE INSTALLATION OF ALL
ACCESSIBLE FIXTURES AND ACCESSORIES, UNLESS MORE SPECIFIC
DIMENSIONS ARE SHOWN ELSEWHERE IN THE CONTRACT DOCUMENTS THAT
ARE WITHIN THE PERMISSIBLE LIMITS SHOWN HERE.
• REFER TO INTERIOR ELEVATIONS FOR MOUNTING LOCATIONS OF RESTROOM
FIXTURES AND ACCESSORIES.
• PROVIDE BACKING AT ALL WALL MOUNTED FIXTURES, ACCESSORIES, AND
EQUIPMENT. COORDINATE BACKING REQUIREMENTS WITH ITEM
MANUFACTURER'S CURRENT WRITTEN INSTALLATION INSTRUCTIONS.
N.T.S.
B6
LAVATORY & ACCESSORY
CLEARANCES & HEIGHT
REQUIREMENTS
N.T.S.
B5 TOILET COMPARTMENT CLEARANCE REQUIREMENTS
N.T.S.
C3 URINAL CLEARANCE REQUIREMENTS
N.T.S.
E6 TUB & SHOWER CLEARANCES & ACCESSORY HEIGHT REQ.
N.T.S.
E3 ELECTRIC WATER COOLER REQUIREMENTS
N.T.S.
C6 ELONGATED OPENINGS
N.T.S.
C5 RAMP LANDINGS
N.T.S.
C4 HANDRAIL REQUIREMENTS
60" MIN
M
IN
MIN
12" 36" MIN
MIN
12"
M
IN
M
IN
A R
M
A R
M
BASE
T-SHAPED TURNING SPACE
(EXISTING BUILDINGS)
60" MIN.
>1 5"
MANEUVERING CLEARANCE IN AN
ALCOVE, PARALLEL APPROACH
NEW BUILDING - CLEAR
FLOOR OR GROUND SPACE
52"
M
IN
43" MIN.
43" MIN.
<52"
180 DEGREE TURN
NEW BUILDING
CLEAR WIDTH AT TURN
M A
X
M
IN
VERTICAL CLEARANCE
30" MIN
M
IN
52" MIN
M
IN
36" MIN
POSITION OF CLEAR FLOOR OR GROUND SPACE
(A) FORWARD (A) PARALLEL
MANEUVERING CLEARANCE IN AN
ALCOVE,
FORWARD APPROACH
>2 4"
A R
M
A R
M
BASE
T-SHAPED TURNING SPACE (A)
(NEW BUILDINGS)
64" MIN
M
IN
MIN
11" 42" MIN
MIN
11"
M
IN
M
IN
A R
M
A R
M
BASE
T-SHAPED TURNING SPACE (B)
(NEW BUILDINGS)
64" MIN
M
IN
MIN
12" 40" MIN
MIN
12"
M
IN
M
IN
A R
M
A R
M
BASE
T-SHAPED TURNING SPACE (C)
(NEW BUILDINGS)
M
IN
36" MIN.
36" MIN.
<52"
180 DEGREE TURN
NEW BUILDING
M
IN
42" MIN.
42" MIN.
<52"
180 DEGREE TURN
NEW BUILDING
M
IN
68" MIN
M
IN
M
IN
MIN.
8"
8" M
IN
MIN
16"
MIN
36"
MIN
16"
M
IN
NEW BUILDING - CIRCULAR
TURNING SPACE
10" ø60"ø67"
OVERLAP OF KNEE
& TOE
EXISTING BUILDING -
CIRCULAR TURNING SPACE
EXISITNG BUILDING - CLEAR
FLOOR OR GROUND SPACE
48"
M
IN
TURNING SPACES SHALL BE PERMITTED
TO INCLUDE KNEE AND TOE CLEARANCE
OF EITHER THE BASE OR ONE ARM
M
IN
M
IN
24" MAX
52" MIN.
24" MAX
M
IN
M
IN
CLEAR WIDTH OF AN
ACCESSIBLE ROUTE
NEW BUILDING - INTERIOR
M
IN
42" MIN.
42" MIN.
<48"
180 DEGREE TURN
EXISTING BUILDING
M
IN
36" MIN.
36" MIN.
<48"
180 DEGREE TURN
EXISTING BUILDING
M
IN
M
IN
24" MAX
48" MIN.
24" MAX
M
IN
M
IN
CLEAR WIDTH OF AN
ACCESSIBLE ROUTE
EXISTING BUILDING - INTERIOR
24" MAX.
52" MIN.
24" MAX.
M
IN
M
IN
M
IN
CLEAR WIDTH OF AN
ACCESSIBLE ROUTE
NEW BUILDING - EXTERIOR
24" MAX.
48" MIN.
24" MAX.
M
IN
M
IN
M
IN
CLEAR WIDTH OF AN
ACCESSIBLE ROUTE
EXISTING BUILDING - EXTERIOR
M
IN
M A
X
UNOBSTRUCTED REACH
(A)
FORWARD REACH
(B)
SIDE REACH
10" MAX
M
IN
M A
X
20" MAX
M A
X
M A
X
510-635
>20"-25" MAX
(A)
FORWARD REACH
(B)
FORWARD REACH
M A
X
10" MAX
M A
X
255-610
>10"-24" MAX
(C)
SIDE REACH
(D)
SIDE REACH
KNEE CLEARANCE
OBSTRUCTED HIGH REACH
8" MIN.
9" M
IN
11" MIN. 635
25" MAX
M
IN
(A)
ELEVATION
(B)
PLAN
≥2 7"
4" MAX
LIMITS OF PROTRUDING OBJECTS
M A
X
M A
X
M
IN
TOE CLEARANCE
430-635 17"-25"
M
IN
(A)
ELEVATION
(B)
PLAN
M
IN
6" MAX.
9"
M
IN
18" MIN.
8"
PULL SIDE
NEW & EXISTING BUILDINGS
PUSH SIDE
8"
M
IN
12" MIN.
8"
M
IN
PUSH SIDE, DOOR
PROVIDED WITH BOTH
CLOSER AND LATCH
MANEUVERING CLEARANCES AT RECESSED DOORS
M
IN
22" MIN.
M
IN
24" MIN.
POCKET OR HINGE
APPROACH
STOP OR LATCH APPROACH
32" MIN.
32" MIN.
32" MIN.
HINGED DOOR
SLIDING DOOR FOLDING DOOR
MANEUVERING CLEARANCES AT SLIDING & FOLDING DOORS
M
IN
22" MIN.
**48" MIN. (1220) IF BOTH CLOSER AND
LATCH PROVIDED.
HINGE APPROACH,
PUSH SIDE
LATCH APPROACH,
PULL SIDE
LATCH APPROACH,
PUSH SIDE
HINGE
APPROACH, PULL
SIDE
HINGE APPROACH,
PULL SIDE
*48" MIN. (1220) IF CLOSER
IS PROVIDED
*54" MIN. (1370) IF CLOSER
IS PROVIDED
M
IN
24" MIN.
24" MIN.
M
IN
36" MIN.
M
IN
42" MIN. 13
M
IN
MANEUVERING CLEARANCES AT MANUAL SWINGING DOORS
FRONT APPROACH,
PULL SIDE
FRONT APPROACH,
PUSH SIDE
NEW BUILDINGS
*IF BOTH CLOSER AND LATCH
ARE PROVIDED
FRONT APPROACH, PUSH SIDE,
DOOR PROVIDED WITH BOTH
CLOSER AND LATCH
M
IN
12 MIN
M
IN
M
IN
18 MIN
DOORS IN SERIES
M
IN
M
IN
12" MIN *
64" MIN.
M
IN
DOOR WIDTH
48" MIN DOOR WIDTH DOOR WIDTH
48" MIN
NEW CONSTRUCTION
M
IN
M
IN
DOOR WIDTH
48" MIN DOOR WIDTH
EXISTING CONSTRUCTION
M
IN
DOOR WIDTH
48" MIN
60" MIN
FRONT APPROACH,
PUSH SIDE
EXISTING BUILDINGS
*IF BOTH CLOSER AND LATCH
ARE PROVIDED
M
IN
12" MIN *
PUSH SIDE
8"
M
IN
12" MIN.
8"
M
IN
PUSH SIDE, DOOR
PROVIDED WITH BOTH
CLOSER AND LATCH
CLEAR WIDTH AT DOORWAYS
NEW BUILDINGS EXISTING BUILDINGS
M
IN
FRONT APPROACH
NEW BUILDINGS
M
IN
FRONT APPROACH
EXISTING BUILDINGS
M
IN
FRONT APPROACH
NEW BUILDINGS
M
IN
FRONT APPROACH
EXISTING BUILDINGS
MANEUVERING CLEARANCES FOR DOORWAYS WITHOUT
DOORS OR GATES
M
IN
SIDE APPROACH
INTERNATIONAL
TTY SYMBOL
INTERNATIONAL SYMBOL FOR
ACCESS FOR HEARING LOSS
INTERNATIONAL SYMBOL
FOR ACCESSIBLITY
1. LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED 1/32" MINIMUM AND SHALL BE SANS-
SERIF UPPERCASE CHARACTERS ACCOMPANIED BY GRADE 2 BRAILLE. (SEC. 1117B.5.6.1)
2. RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF 5/8" HIGH. (SEC. 1117B5.6.2)
3. PICTORIAL SYMBOL SIGNS (PICTOGRAMS) SHALL BE ACCOMPANIED BY THE EQUIVALENT
VERBAL DESCRIPTION PLACED DIRECTLY BELOW THE PICTOGRAM. THE BORDER DIMENSION
OF THE PICTOGRAM SHALL BE A MINIMUM OF 6" IN HEIGHT. (SEC. 1117B.5.6.3)
4. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH-TO-HEIGHT RATIO OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH-TO-HEIGHT RATIO BETWEEN 1:5 AND 1:10. (SEC. 1117B.5.3)
5. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND, EITHER LIGHT
CHARACTERS ON A DARK BACKGROUND OR DARK CHARACTERS ON A LIGHT BACKGROUND.
(SEC. 1117B.5.5)
6. CHARACTERS AND NUMBERS ON SIGNS SHALL BE SIZED ACCORDING TO THE VIEWING
DISTANCE FROM WHICH THEY ARE TO BE READ. THE MINIMUM HEIGHT IS MEASURED USING AN
UPPER CASE X. LOWER CASE CHARACTERS ARE PERMITTED. FOR SIGNS SUSPENDED OR
PROJECTED ABOVE THE FINISH FLOOR IN COMPLIANCE WITH SECTION 1121B, THE MINIMUM
CHARACTER HEIGHT SHALL BE 3". (SEC. 1117B.5.4)
7. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHEREVER BRAILLE SYMBOLS ARE
SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE REGULATIONS. DOTS SHALL BE 1/10"
ON CENTERS IN EACH CELL WITH 2/10" SPACE BETWEEN CELLS. DOTS SHALL BE RAISED A
MINIMUM OF 1/40" ABOVE THE BACKGROUND. (SEC. 1117B.5.2)
LETTERS AND NUMBERS:
SIGN LOCATIONS:
1. ALL BUILDING ENTRANCES THAT ARE ACCESSIBLE TO AND USABLE BY PERSONS WITH
DISABILITIES AND AT EVERY MAJOR JUNCTION ALONG OR LEADING TO AN ACCESSIBLE ROUTE
OF TRAVEL SHALL BE IDENTIFIED WITH A SIGN DISPLAYING THE INTERNATIONAL SYMBOL OF
ACCESSIBILITY AND WITH ADDITIONAL DIRECTIONAL SIGNS, AS REQUIRED, TO BE VISIBLE TO
PERSONS ALONG APPROACHING PEDESTRIAN WAYS. (SEC. 1117B.5.7 & 1127B.3)
2. WHEN PERMANENT IDENTIFICATION IS PROVIDED FOR ROOMS AND SPACES, RAISED LETTERS
SHALL BE PROVIDED AND SHALL BE ACCOMPANIED BY BRAILLE IN CONFORMANCE WITH
SECTION 1117B.5.6. SIGNS SHALL BE INSTALLED ON THE WALL ADJACENT TO THE LATCH
OUTSIDE OF THE DOOR. WHERE THERE IS NO WALL SPACE ON THE LATCH SIDE, INCLUDING AT
LEAF DOORS, SIGNS SHALL BE PLACE ON THE NEAREST ADJACENT WALL, PREFERABLY ON
THE RIGHT. MOUNTING HEIGHT SHALL BE 60" ABOVE THE FINISH FLOOR TO THE CENTERLINE
OF THE SIGN. MOUNTING LOCATION SHALL BE DETERMINED SO THAT THE PERSON MAY
APPROACH WITHIN 3" OF THE SIGNAGE WITHOUT ENCOUNTERING PROTRUDING OBJECTS OR
STANDING WITHIN THE SWING OF A DOOR. (SEC. 1117B.5.9)
3. ADDITIONAL DIRECTIONAL SIGNS ALONG ACCESSIBLE PATH OF TRAVEL ARE REQUIRED.
4. BUILDINGS REMODELED TO PROVIDE ACCESSIBLE SANITARY FACILITIES FOR PUBLIC USE
SHALL HAVE INFORMATION POSTED IN THE LOBBY AS PART OF THE BUILDING DIRECTORY.
1. STANDARD USED TO IDENTIFY ACCESSIBLE FACILITIES.
2. WHITE FIGURE ON BLUE BACKGROUND, COLOR # 15090 ON FEDERAL STANDARD # 595A.
3. WHEN ENFORCING AGENCY DETERMINES, IF APPROPRIATE, SPECIAL DESIGNS AND COLORS
MAY BE APPROVED.
INTERNATIONAL SYMBOL
OF ACCESSIBILITY:
1. USE CONTRASTED GRADE 2 BRAILLE. DOTS TO BE 0.1 INCH ON CENTER IN EACH CELL.
2. 0.2 INCH SPACE BETWEEN CELLS.
3. DOTS RAISED MINIMUM 0.025 INCH ABOVE BACKGROUND.
4. SEE 4/T-4 FOR MORE INFO.
BRAILLE:
VOLUME-CONTROLLED
TELEPHONE
M
IN
18" MIN
CENTERED ON
RAISED CHARACTERS
6" M
IN
MEN
NOT IN
PICTOGRAM
FIELD
AREA OF
REFUGE
3/ 8"
M
IN
3/
8" M
IN
AREA OF
REFUGE
M
IN
. W /O
B R
A
IL
LE
M A
X . W
/O B
R A
IL
LE
DOOR SIGNAGE
M
IN
. W / B
R A
IL
LE
M A
X . W
/ B R
A
IL
LE
6.
1/ 4"
6.
1/ 4"
131/ 2"
BEVELED CHANGE IN LEVEL (A)
CARPET PILE HEIGHT
1/
2" M
A X
VERTICAL CHANGE IN LEVEL
6.
1/
M A
X
BEVELED CHANGE IN LEVEL (B)
6.
4-
1/
4"
1/ 2"
AHJ STAMP COPYRIGHT 2026
STEELE ASSOCIATES ARCHITECTS
All rights reserved. Reproduction or use in any form or by any means- graphic, electronic, mechanical, etc.- without written permission of STEELE ASSOCIATES ARCHITECTS is unlawful and subject to criminal prosecution.
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
N
W P
O T
T S
C T
S
U
IT
E
B E
N D
O
R
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
5 4 3 2 16
B
C
D
E
B
C
D
E
AA
/4
/2
:3
:0
P
M
G005
CTLG
17127.02
P E
R M
IT
S
E T
A D
A R
E Q
U
IR
E M
E N
T S
ADA REQUIREMENTS
09.04.2026
C H
IL
O
Q U
IN
B
L V
D
K L
A M
A T
H T
R
IB
E S
F
IT
N E
S S
C E
N T
E R
A D
D
IT
IO
N
C H
IL
O
Q U
IN
O
R E
G O
N
N.T.S.
B6 CLEAR FLOOR SPACE & HEIGHT REQUIREMENTS
N.T.S.
D6 REACH REQUIREMENTS
N.T.S.
E6 DOOR AND DOORWAY CLEARANCE REQUIREMENTS
N.T.S.
D3 SIGNS - PICTOGRAMS
N.T.S.
D4 LEVEL CHANGE
USE
OCCUPANCY
MLOAD M RATIO
WATER CLOSETS LAVATORIES FOUNTAIN
F RATIO F
SUBTOTAL
PROVIDED
MRATIO F
3.34 2.652.65
REQUIRED 4 6 3
RATIO
STORAGE/
MECH/EQUIP 11 6 5 1/100 0.06
3 + BOTTLE
FILLERS
-1/100 -0.6
5+
2cd 7c 5c5c
1/100
a. ONE WATER CLOSET REQUIRED PER 25 OCCUPANTS FOR THE FIRST 50 OCCUPANTS.
b. ONE LAVATORY REQUIRED PER 40 OCCUPANTS FOR THE FIRST 80 OCCUPANTS.
c. SOME RESTROOMS ARE GENDER NEUTRAL. THOSE QUANTITIES DIVIDED EQUALLY FOR GENDER COUNTS.
d. WHERE SEPARATE FACILITIES ARE PROVIDED BY GENDER, URINALS MAY BE SUBSTITUTED FOR UP TO 67% OF
THE REQUIRED WATER CLOSETS FOR MALES IN EACH MALE BATHROOM OR TOILET ROOM.
0.05 1/100 0.5
5.03
RATIO TOTAL
SHOWER
2 ADA
TOTAL
ASSEMBLY 460 230 230 1/125 1.84 11/200
1/
FLOOR
1.151/65 3.54 1/200 1.15 -
BUSINESS 72 36 36
1/25a
1/50
1.44 -
1/40b
1/80 -0.90
1/25a
1/50 1.44
1/40b
1/80
0.90 -
AHJ STAMP COPYRIGHT 2026
STEELE ASSOCIATES ARCHITECTS
All rights reserved. Reproduction or use in any form or by any means- graphic, electronic, mechanical, etc.- without written permission of STEELE ASSOCIATES ARCHITECTS is unlawful and subject to criminal prosecution.
A S
S O
C
IA
T E
S A
R C
H
IT
E C
T S
L L C
N
W P
O T
T S
C T
S
U
IT
E
B E
N D
O
R
JOB NO.
DATE
DRAWN BY CHECKED BY
SHEET NO.
5 4 3 2 1
5 4 3 2 16
B
C
D
E
B
C
D
E
AA
/4
/2
:3
:0
P
M
G006
CTJH
17127.02
P E
R M
IT
S
E T
C O
D E
S U
M M
A R
Y
CODE SUMMARY
09.04.2026
C H
IL
O
Q U
IN
B
L V
D
K L
A M
A T
H T
R
IB
E S
F
IT
N E
S S
C E
N T
E R
A D
D
IT
IO
N
C H
IL
O
Q U
IN
O
R E
G O
N
Applicable Codes:
2025 Oregon Structural Specialty Code (OSSC) 2025 Oregon Mechanical Specialty Code (OSMC) 2023 Oregon Electrical Specialty Code (OESC) 2023 Oregon Plumbing Specialty Code (OPSC) 2017 ICC A117.1 Accessible and Usable Buildings and Facilities 2025 Oregon Fire Code 2024 Oregon Energy Efficiency Specialty Code (ASHRAE 90.01-2022)
Summary:
Occupancy Group: B (BUSINESS) and A-3 (Community Room and Fitness Center) Construction Type: V-B Risk Category: III Sprinklers: Yes Fire Alarm: Yes
Project Description:
20,319 SF Addition to a 15,152 SF fitness center. Total SF: 35,471 SF
Chapter 3 Occupancy Classification Section 304 - Business, Group B Section 303.4 - Assembly, Group A-3
Chapter 5 General Building Heights & Areas Table 504.3 - Allowable Building Height above grade plane
Occupancy Classification B - VB Construction - Sprinklered - max 60 feet in height Occupancy Classification A-3 - VB Construction - Sprinklered - max 60 feet in height
Table 504.4 - Allowable Number of Stories above grade plane Occupany Classification B - VB Constuction - Sprinklered - max 3 stories Occupany Classification A-3 - VB Constuction - Sprinklered - max 2 stories
Table 506.2 - Allowable Area Occupancy Classification B - VB Construction - Sprinklered max. 36,000 SF Occupancy Classification A-3 - VB Construction - Sprinklered max. 24,000 SF
506.3 - Frontage increase: Every building shall adjoin or have access to a public way to receive an area factor increase based on frontage. Area factor increase shall be determined in accordance with Sections 506.3.1 through 506.3.3.
Area Frontage Calculations:
Total building perimeter (Expansion & Existing) = 403 Linear Feet Percentage of building perimeter having min 20' public way or open space = 100% Frontage Increase Factor (75%-100% of building perimeter is 30'+ distance) = 0.75 Allowable Area = 36,000 SF + (9,000 x 0.75= 6,750 SF) = 42,750 SF (B Occupancy)
24,000 SF + (6,000 x 0.75= 4,500 SF) = 28,500 SF (A-3/A-4 Occupancy)
Existing Building GSF (15,152 SF) + Proposed Expansion GSF (20,319 SF)
508.3.3 - Allowable building area, height, and number of stories: The allowable building area, height, and number of stories of the building shall be based on the most restrictive allowances for the occupancy groups under consideration for the type of construction of the building.
Table 508.4 - Required Separation of Occupancies A-3 Occupancy to B Occupancy = 2 Hour (w/Fire Sprinklers)
Addition + Existing B Occupancy = 11,109 SF (Addition) and 4,944 (Existing) A-3 Occupancy = 9,210 SF (Addition) A-4 Occupancy = 10,208 (Existing)
Separated Occupancies: Total Building
B Occupancy: 16,053 SF / 42,750 SF = 0.38 A-3/A-4 Occupancy: 19,418 SF / 28,500 = 0.68
0.38 + 0.68 = 1.06 > 1 (2 Hour Fire Wall Spearation required)
Chapter 6 Types of Construction -
602.5 - Construction Type V-B: any materials, non-rated assemblies Table 601 - Fire-Resistance Rating Requirements for Building Elements
Structural frame - 0-hr Bearing walls, exterior - 0-hr Bearing walls, interior - 0-hr Non-bearing walls and partitions, interior - 0-hr Floor construction and secondary members - 0-hr Roof construction - 0-hr
Chapter 7 Fire and Smoke Protection Features
705.2 Minimum Distance of Projections
FSD (feet) Minimum Distance from FSD line 0 to less than 2 Projections not permitted 2 to less than 3 24" 3 to less than 5 24" + 8" for every foot of FSD beyond 3' or fraction thereof 5 or greater 40"
The building is greater than 10'-0" from the FSD line. All projections are more than 40" away from the FSD line.
Table 705.5 - Fire-Resistance Rating for Exterior Walls based on FSD B/ A3 Occupancy Separation < 5' 2-hr Separation >5' and <10' 1-hr Separation >10' and < 30' 0-hr All walls are >10' and <30' from property boundary, no rating required.
705.8 Openings
West Facade - >30' FSD East Facade - >30' FSD North Facade - >10' FSD South Facade - >10' FSD
706 Fire Walls
706.4 Fire Resistance Rating
A-3 to B/A-4: 3 Hours *In Type II and Type V Construction, walls shall be permitted to have a 2 hour fire resistance rating.
706.5 Horizontal Continuity
Exception:
2. Fire walls shall be permitted to terminate at the interior surface of noncombustible exterior sheathing, exterior siding or other noncombustible exterior finishes provided that the sheathing, siding or other exterior noncombustible finish extends a horizontal distance of not less than
4 feet (1220 mm) on both sides of the fire wall.
706.6 Vertical Continuity
Exception:
4. In buildings of Types III, IV and V construction, walls shall be permitted to terminate at the underside of combustible roof sheathing or decks, provided that all of the following requirements are met:
4.1. Roof openings are not less than 4 feet (1220 mm) from the fire wall.
4.2. The roof is covered with a minimum Class B roof covering.
4.3. The roof sheathing or deck is constructed of fire-retardant-treated wood for a distance of 4 feet (1220 mm) on both sides of the wall or the roof is protected with 5/g-inch (15.9 mm) Type X gypsum board directly beneath the underside of the roof sheathing or deck, supported by not less than 2-inch (51mm) nominal ledgers attached to the sides of the roof framing members for a distance of not less than 4 feet (1220 mm) on both sides of the fire wall.
716 - Opening Protectives 2 hour fire wall shall have door protectinos of 90 min. (Table 716.1) Foor vision panel size - 100 sq. in.
Window frames and glazing shall have 120 minute rating (Table 716.1(3))
718.2 - Fireblocking
718.2.2. - Fireblocking shall be provided in concealed spaces of stud walls, horizontally at intervals not exceeding 10 feet.
1010 - Doors
1010.1.1.1 - Projections into clear width. There shall not be projections into the required clear width lower than 34 inches above the floor or ground. Projections into the clear opening width between 34 inches and 80 inches above the floor or ground shall not exceed 4 inches.
1010.1.3 - The opening force for interior side-swing doors without closers shall not exceed a 5 lb force.
For other side-swing, sliding and folding doors, the door latch shall release when subjected to a 15 lb force. The door shall be set in motion when subjected to a 30 lb force. The door shall swing to a full-open position when subjected to a 15 lb force. Forces shall be applied to the latch side.
1010.1…
This is the start of the file's text. The full file is on GovTribe.