Excerpt Bldg 47 JHQVAMC Draft LCP Screening Survey Report 1-16-23.pdf

PDF 1 MB Posted

Attached to
Z2AA--621-23-106 - Restore Exteriors of Historical Quarters
Solicitation number
36C24923B0007
Issued by

About this file

This document contains an excerpt from a draft lead contamination screening survey report and the related federal contract solicitation. The screening survey report details lead testing results for various materials in several buildings at the James H. Quillen VA Medical Center, identifying levels found in walls, windows, doors, and other structures.

The related federal contract solicitation seeks restoration of exteriors on four historical quarters buildings at the same VA Medical Center location. The awarded contractor will be responsible for restoration and renovation work including replacing wood, installing water barriers, painting, conducting roof repairs, tuckpointing brick, and replacing gutters over a 400-day period of performance. The solicitation provides details on supervision, planning and drawing requirements, site visits, deliveries, inspections, submittals, and other project terms.

View the file

Other files

File Type Posted
36C24923B0007 0003.pdf PDF
Drawings 621-23-106 Amendment 3.3.2023.pdf PDF
Agenda Site Visit 621.23.106 Restore Ext Qtrs Bldgs (16 Feb 2023).pdf PDF
Specifications 621_23_106 3.3.23.pdf PDF
Sign In Site Visit 621.23.106 Restore Ext Qtrs Bldgs (16 Feb 2023).pdf PDF
36C24923B0007 0002.pdf PDF
36C24923B0007 0001.pdf PDF
DUNS _ TAX ID.docx DOCX document
Drawings 621-23-106 Restore Exteriors for Quarters Buildings 262023.pdf PDF
Excerpt Bldg 45 JHQVAMC Draft Asbestos Survey Report 01-06-23.pdf PDF
Excerpt Bldg 45 JHQVAMC Draft LCP Screening Survey Report 1-16-23.pdf PDF
Building 46 ACM Report 2006.pdf PDF
Excerpt Bldg 46 JHQVAMC Draft LCP Screening Survey Report 1-16-23.pdf PDF
Excerpt Bldg 15 JHQVAMC Draft LCP Screening Survey Report 1-16-23.pdf PDF
Contractor EMR Certification Form.docx DOCX document
Building 15 ACM Report 2006.pdf PDF
Specifications 621-23-106 Restore Exteriors for Quarters Buildings 2723.pdf PDF
Excerpt Bldg 46 JHQVAMC Draft Asbestos Survey Report 01-06-23.pdf PDF
RFI Form 621-23-106.docx DOCX document
36C24923B0007_1.docx DOCX document
Excerpt Bldg 47 JHQVAMC Draft Asbestos Survey Report 01-06-23.pdf PDF
Building 45 ACM Report 2006.pdf PDF
Drawings 621-23-106 Restore Exteriors for Quarters Buildings (18 Jan 2023).pdf PDF
Davis-Bacon Act WD TN20230191.txt TXT text file
Excerpt Bldg 15 JHQVAMC Draft Asbestos Survey Report 01-06-23.pdf PDF
COVID Language_Updated 12-14-2021.docx DOCX document
Building 47 ACM Report 2006.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

APPENDIX B.21

BUILDING 47

LEAD SAMPLE SUMMARY TABLE

BUILDING 47

XRF READINGS

HA NO. Color & Substrate XRF Sample

No.

Sample Location /

Room Number Results mg/cm2

Estimated Quantities

Pre-Sampling Calibration Readings

NA

1.0

NA

2 1.0

3 1.0

4 1,0

Post Sampling Calibration Readings

79 1.1

80 1.0

81 1.0

82 1.0

Cream Plaster

Wall

5 Room 101 <

5,800 ft²

11 Room 100 3.3

12 Room 102 2.8

23 Room 104 <

33 Room 205 2.4

34 Room 207 <

35 Room 201 <

36 Room 200 <

White Window

Frame

6 Room 101 <

NA

30 Room 104 <

White Wood

Window

7 Room 101 <

NA

31 Room 104 <

White Window

Frame

8 Room 101 <

NA40 Room 207 <

43 Room 205 <

05 White Window

9 Room 101 <

NA41 Room 207 <

44 Room 205 <

White Plaster

Ceiling

13 Room 100 <

NA32 Room 103 <

42 Room 200 <

Cream Wood Door

Frame

14 Room 100 3.7

38 Frames37 Room 200 3.0

45 Room 201 5.7

XRF READINGS

HA NO. Color & Substrate XRF Sample

No.

Sample Location /

Room Number Results mg/cm2

Estimated Quantities

08 Cream Wood Door

15 Room 100 6.0

38 Doors38 Room 200 4.8

47 Room 201 7.0

Cream Wood Baseboard

16 Room 100 2.1

600 ft39 Room 200 3.3

46 Room 207 2.8

Cream Wood Stair

Components

17 Room 100 5.0

200 ft²18 Room 100 4.0

20 Room 100 6.9

Bronze Wood

Handrail

19 Room 100 0.3

75 ft21 Room 100 0.3

22 Room 200 0.3

Yellow Plaster

Wall

24 Room 105 <

200 ft225 Room 105 0.4

26 Room 105 <

Lavender Plaster

Wall

27 Room 103 <

NA28 Room 103 <

29 Room 103 <

Tan Ceramic Tile

Wall

48 Room 203 <

NA49 Room 203 <

50 Room 203 <

15 White Brick Wall

51 Room B102 <

NA

52 Room B103 <

53 Room B103 <

54 Room B101 <

Gray on Concrete

Floor

55 Room B102 <

1,500 ft256 Room B104 <

57 Room B105 0.5

White Plaster

Ceiling

58 Room B102 0.3

200 ft²59 Room B102 0.2

60 Room B102 <

18 White Wood Ceiling

61 Room B100 <

NA62 Room B100 <

63 Room B101 <

Gray Wood Stair

Components

64 Stringer 3.6

200 ft265 Picket 4.6

66 Handrail <

XRF READINGS

HA NO. Color & Substrate XRF Sample

No.

Sample Location /

Room Number Results mg/cm2

Estimated Quantities

67 Stair Tread 0.7

68 Stair Riser 3.5

White Wood

Siding

69 Exterior Porch <

4,600 ft270 Exterior Porch <

71 Exterior Porch <

White Brick Foundation

72 Exterior 6.1

600 ft²76 Exterior 5.4

78 Exterior 5.7

White Wood Rim

Board

73 Exterior 2.4

200 ft²75 Exterior <

77 Exterior 5.8

CHIP SAMPLES

HA NO. Color & Substrate Chip Sample

No.

Sample Location /

Room Number Results

% by weight

Cream Paint on

Wood Door Frame Pb-1 Room 104 <0.016

White Paint on Plaster Ceiling

Pb-2 Room 103 <0.0080

Gray Paint on

Concrete Floor Pb-3 Room B104 1.1

White Paint on Wood Siding

Pb-4 Exterior 0.039

< indicates the result is below the level of detection for the XRF instrument or laboratory (chip samples).

OrderID: 412208922

VA Mountain Home Lead-Paint Photo Page - 18227196 Building 47, Mountain Home, Tennessee Date photos taken: August 31, 2022

Photo #1 HA 01 cream paint on plaster walls, (lead-based).

Photo #2 HA 02 white paint on wooden 8 lite window frame.

Photo #3 HA 03 white paint on wooden 8 lite window.

Photo #4 HA 04 white paint on wooden 16 lite window frame.

Photo #5 HA 05 white paint on wooden 16 lite window.

Photo #6 HA 06 white paint on plaster ceiling.

Photo #7 HA 07 cream paint on wooden door frame, (lead-based).

Photo #8 HA 08 cream paint on wooden door frame, (lead-based).

Photo # HA 09 cream paint on wooden base board, (lead-based).

Photo #10 HA 10 cream paint on wooden stair components, (lead-based).

Photo #11 HA 11 bronze paint on wooden handrail, (lead containing).

Photo #12 HA 12 yellow paint on plaster walls, (lead containing).

Photo #13 HA 13 lavender paint on plaster wall.

Photo #14 HA 14 tan glazing on ceramic wall tile.

Photo #15 HA 15 white paint on brick wall. Photo #16 HA 16 gray paint on concrete floor, (lead containing).

Photo #17 HA 17 white paint on plaster ceiling, (lead containing)

Photo #18 HA 18 white paint on wooden ceiling members.

Photo #19 HA 19 gray paint on wooden stair components, (lead-based).

Photo #20 HA 20 white paint on exterior wooden siding.

Photo #21 HA 21 white paint on brick foundation, (lead-based).

Photo #22 HA 22 white paint on wooden rim board, (lead-based).

Photo #23 Pb-01 white paint on wooden door frame.

Photo #24 Pb-02 white paint on plaster ceiling.

Photo #19 Pb-03 gray paint on concrete floor, (lead-based).

Photo #20 Pb-04 white paint on exterior wooden siding, (lead containing).

JHQVAMC - LEAD APPENDICES without Drawings
Credentials
Building 3 Lead Appendix
Sheets
3D-03 - 3D Building
LE-03_01 - Lead Plan - Basement
LE-03_02 - Lead Plan - First Floor
LE-03_03 - Lead Plan - Second Floor
LE-03_04 - Lead Plan - Attic
Building 5 Lead Appendix
Sheets
3D-05 - 3D Building
LE-05_01 - Lead Plan - Basement
LE-05_02 - Lead Plan - First Floor
LE-05_03 - Lead Plan - Second Floor
LE-05_04 - Lead Plan - Attic

JHQVAMC LCP Sampling and Plan JD AJM

SCiAps_X-550_PCS_Feb22

File details come from the government source that posted it. Updated .