This solicitation is for restoration services at the James H. Quillen VA Medical Center in Mountain Home, Tennessee. The selected contractor will restore the exteriors of five historical quarters buildings located at the medical center over a 400-day period of performance. The scope of work includes replacing wood, installing water barriers, conducting roof repair and replacement, tuckpointing and repairing brick foundations and chimneys, replacing gutters and downspouts, and extending downspout discharges. The contractor must provide project management and coordination, submittals, samples, and schedule. Work will generally take place Monday through Thursday from 8:00 am to 5:00 pm, though some after-hours work may be approved. The contractor must follow all VA security, parking, and smoking policies at the site.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
APPENDIX B.20
BUILDING 46
LEAD SAMPLE SUMMARY TABLE
BUILDING 46
XRF READINGS
HA NO. Color & Substrate XRF Sample No.
Sample Location / Room Number
Results mg/cm2
Estimated Quantity
NA
Pre-Sampling Calibration Readings
NA
1.0
NA
2 0.9
3 1.0
4 1.0
Post Sampling Calibration Readings
110 1.1
111 1.0
112 1.0
113 1.0
Cream Plaster
Wall
7 101 0.2
5,600 ft²
25 106 2.2
31 107 0.4
38 201 0.1
46 204 0.3
59 200 0.1
60 200 0.1
White Plaster
Ceiling
11 100 0.4
4,000 ft²
44 201 <
54 203 <
61 200 <
75 B102 0.2
White Wood Door
Frame
12 100 4.8
40 Frames 27 106 4.5
57 205 4.1
73 B102 1.8
04 White Wood Door
13 100 2.3
43 Doors 28 106 3.0
58 205 2.3
74 B102 3.7
White Wood
Window Frame
19 102 < windows 34 107 <
64 B103 1.9
White Wood
Window
20 102 < windows 35 107 <
65 B103 3.1
XRF READINGS
HA NO. Color & Substrate XRF Sample No.
Sample Location / Room Number
Results mg/cm2
Estimated Quantity
White Wood Stair
Components
14 100 Stair Stringer 5.8
200 ft215 100 Stair Picket 3.9
16 100 Newel Post 4.9
White Exterior
Wood Components
89 Front Porch Column 8.2
4,600 ft²100 Siding 5.2
108 Rim Board <
White Brick Foundation
94 Front Porch Foundation <
600 ft²98 Foundation 1.2
109 Foundation 0.3
Gray Concrete
Floor
68 B103 0.5
1,500 ft²76 B102 0.2
83 B100 0.3
12 White Plaster Wall
55 205 0.2
300 ft256 205 0.3
52 203 <
13 White brick walls
78 B101 0.5
1,500 ft²62 B103 <
69 B102 <
14 Wood ceiling 66 B103 <
200 ft2
67 B103 0.1
CHIP SAMPLES
HA NO. Color & Substrate Chip Sample No.
Sample Location / Room Number
Results % by weigh
White Brick Foundation
Pb-01 Foundation 6.7
13 Seafoam Brick Wall Pb-02 B100 0.043
White Wood Ceiling
Joist Pb-03 B103 0.025
12 White Plaster Wall Pb-04 100 0.12
White Wood Door
Frame Pb-05 204A 10
NA = Not Applicable < indicates result is below the detection limit for the XRF instrument or laboratory analytical method.
Client Sample Description ConcentrationLab ID Analyzed Weight Lead
Collected
EMSL Analytical, Inc.
10801 Southern Loop Blvd, Pineville, NC 28134 Phone/Fax: (704) 525-2205 / (704) 525-2382 http://www.EMSL.com charlottelab@emsl.com
Attn: Patrick Peoples Terracon 2147 Riverchase Office Road Hoover, AL 35244
Received: 9/7/2022 09:20 AM
James A. Quillen VA Medical Center - Building 46/ 18227196
Fax: (205) 942-1266 Phone: (205) 942-1289
Project:
8/30/2022Collected:
Test Report: Lead in Paint Chips by Flame AAS (SW 846 3050B/7000B)*
412208919 CustomerID: TRCN34 CustomerPO: 18227196 ProjectID:
EMSL Order:
.2343 Site: White Paint on Brick Foundation-Exterior, Side D 412208919-0001Pb-01 6.7 % wt9/9/2022 g8/30/2022
.2879 Site: Sea Foam Paint on Brick Wall-Side C, Room B100 412208919-0002Pb-02 0.043 % wt9/9/2022 g8/30/2022
.2588 Site: White Paint on Wood Ceiling Joist-Room B103 412208919-0003Pb-03 0.025 % wt9/9/2022 g8/30/2022
.2607 Site: White Paint on Plaster Wall-Side B, Room 101 412208919-0004Pb-04 0.12 % wt9/9/2022 g8/30/2022
.2637 Site: White Paint on Wood Door Frame-Side C, Room 202A 412208919-0005Pb-05 10 % wt9/9/2022 g8/30/2022
Aaron Hartley, Lead Technical Manager or other approved signatory
Test Report ChmSnglePrm/nQC-7.32.3 Printed: 9/12/2022 8:19:15 AM
EMSL maintains liability limited to cost of analysis. Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations. The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted.
* Analysis following Lead in Paint by EMSL SOP/Determination of Environmental Lead by FLAA. Reporting limit is 0.008% wt based on the minimum sample weight per our SOP. "<" (less than) result signifies the analyte was not detected at or above the reporting limit. Measurement of uncertainty is available upon request. Definitions of modifications are available upon request.
Samples analyzed by EMSL Analytical, Inc. Pineville, NC AIHA-LAP, LLC - ELLAP 192283
Initial report from 09/12/2022 08:19:15
OrderID: 412208919
VA Mountain Home Lead-Paint Photo Page - 18227196 Building 46, Johnson City, Tennessee Date photos taken: August 30, 2022
Photo #1 HA 01 cream paint on plaster walls, (lead-based).
Photo #2 HA 02 white paint on plaster ceilings, (lead containing).
Photo #3 HA 03 white paint on wooden door frames, (lead-based).
Photo #4 HAs 03 & 04 white paint on wood door frames and wood doors, (lead-based).
Photo #5 HAs 05 & 06 white paint on wood window frames and wood windows, (lead-based).
Photo #6 HA 06 white paint on wooden windows, (lead-based).
Photo #7 HA 08 white paint on wooden stair components, (lead-based).
Photo #8 HA 09 white paint on wooden exterior components, (lead-based).
Photo #9 HA 10 white paint on brick foundation, (lead-based).
Photo #10 Pb-01 white paint on brick foundation, (lead-based).
Photo #11 Pb-02 seafoam paint on brick wall, (lead containing).
Photo #12 Pb-03 white paint on wood ceiling joist, (lead containing).
Photo #13 Pb-04 white paint on plaster wall, (lead containing).
Photo #14 Pb-05 white paint on wooden door frame, (lead-based).
| JHQVAMC - LEAD APPENDICES without Drawings |
| Credentials |
| Building 3 Lead Appendix |
| Sheets |
| 3D-03 - 3D Building |
| LE-03_01 - Lead Plan - Basement |
| LE-03_02 - Lead Plan - First Floor |
| LE-03_03 - Lead Plan - Second Floor |
| LE-03_04 - Lead Plan - Attic |
| Building 5 Lead Appendix |
| Sheets |
| 3D-05 - 3D Building |
| LE-05_01 - Lead Plan - Basement |
| LE-05_02 - Lead Plan - First Floor |
| LE-05_03 - Lead Plan - Second Floor |
| LE-05_04 - Lead Plan - Attic |
JHQVAMC LCP Sampling and Plan JD AJM
SCiAps_X-550_PCS_Feb22
File details come from the government source that posted it. Updated .