This document is an attachment to a state and local contract opportunity solicited by the Texas Military Department (TMD), Texas Air National Guard (ANG) 147th Attack Wing for the repair of existing radio frequency (RF) cable at the 35 localizer at Ellington Field in Houston, Texas. The project involves manually trenching and removing previously damaged RF heliax cable, and replacing it with 150 linear feet of new cable and conduits at Building 1452. The contract requires the successful contractor to provide trained personnel to coordinate and expedite training, attend training coordination meetings, and provide detailed classroom and hands-on training to Ellington Field personnel on the operation and maintenance of the specified equipment. The contract does not specify a contract term or renewal options.

The contract opportunity does not provide details on pricing terms, set asides, incumbents, funding requirements and sources, or other salient commercial information. However, it does require the contractor to submit various submittals, including a training schedule, preliminary and final training plans, training materials, and manufacturer's certificates of proper installation.

View the file

Other files

File Type Posted
ESBD_371089_1723062377226_ATTACHMENT G.E - Ellington Field (EF) Safety Policies And Procedures.pdf PDF
ESBD_371089_1723062692834_ATTACHMENT G.I - Ellington Field (EF) Houston Texas Standard Operating Procedure (Sop) For Inadvertent Discovery Of Cultural Materials.pdf PDF
ESBD_371089_1723061838423_ATTACHMENT G.1 Direct Deposit Authorization Form.pdf PDF
ESBD_371089_1723062860299_ATTACH~3.PDF PDF
ESBD_371089_1723063388690_AT2598~1.PDF PDF
ESBD_371089_1723062537933_ATTACHMENT G.F.2 - Ellington AFB (EF) Contractor Hazardous Material Identification Form Close-Out Procedures.pdf PDF
ESBD_371089_1723062454062_ATTACHMENT G.F - Ellington Field (EF) EMS Hazardous Material Procedures.pdf PDF
ESBD_371089_1723062521452_ATTACHMENT G.F.1 - Ellington AFB (EF) Contractor Hazardous Material Usage Data.pdf PDF
ESBD_371089_1723062307951_ATTACHMENT G.D - Ellington AFB (EF) Field Engineering.pdf PDF
ESBD_371089_1723061872655_ATTACHMENT G.2 Application for Texas Identification Number.pdf PDF
ESBD_371089_1723062831590_ATTACHMENT G.J.1 - Ellington AFB (EF) Maintenance Summary Form.pdf PDF
ESBD_371089_1723063298033_ATTACH~2.PDF PDF
ESBD_371089_1723061940566_ATTACHMENT G.4 Pricing Schedule.pdf PDF
ESBD_371089_1723062969469_ATTACH~2.PDF PDF
ESBD_371089_1723062990834_ATTACHMENT G.O - Ellington Field (EF) Starting Of Systems.pdf PDF
ESBD_371089_1723061909201_ATTACHMENT G.3 TMD Standard Terms and Conditions.pdf PDF
ESBD_371089_1723062041430_ATTACHMENT G.7 Trench Details.pdf PDF
ESBD_371089_1723063157585_ATTACH~2.PDF PDF
ESBD_371089_1723062600331_ATTACHMENT G.G - Ellington AFB (EF) Quality Control.pdf PDF
ESBD_371089_1723062025654_ATTACHMENT G.6 Four (4) Site Photos.pdf PDF
ESBD_371089_1723654956338_ESBD Addendum 1 - TMD24-ANG-WJ-24150009.pdf PDF
ESBD_371089_1723062100169_ATTACHMENT G.A - Ellington Field (EF) General Requirements.pdf PDF
ESBD_371089_1724098412133_ESBD Addendum 2 - TMD24-ANG-WJ-24150009.pdf PDF
ESBD_371089_1723063316199_ATTACH~3.PDF PDF
ESBD_371089_1723063353258_ATTACHMENT G.W - Ellington AFB (EF) AF103_REV.pdf PDF
ESBD_371089_1723062252989_ATTACHMENT G.B - Ellington Field (EF) Coordination And Meetings.pdf PDF
ESBD_371089_1723061959244_ATTACHMENT G.5 Photo Overview.pdf PDF
ESBD_371089_1723062876491_ATTACHMENT G.M - Ellington AFB (EF) Material Equipment.pdf PDF
ESBD_371089_1723062848141_ATTACH~2.PDF PDF
ESBD_371089_1723062731760_ATTACHMENT G.J - Ellington Field (EF) Operation And Maintenance Data.pdf PDF
ESBD_371089_1723063286623_ATTACHMENT G.T - Ellington Field (EF) Post Award Submittals.pdf PDF
ESBD_371089_1723062652487_ATTACHMENT G.H - Ellington Field (EF) EMS Environmental Protection.pdf PDF
ESBD_371089_1723062296770_ATTACHMENT G.C - Ellington AFB (EF) Project Coordination.pdf PDF
ESBD_371089_1723061785599_TMD24-ANG-WJ-24150009 Ellington Cable Repair.pdf PDF
ESBD_371089_1723063177299_ATTACHMENT G.S - Ellington AFB (EF) Substitutions Request Form.pdf PDF
ESBD_371089_1723063015395_ATTACHMENT G.P - Ellington Field (EF) Contract Closeout.pdf PDF
ESBD_371089_1723063367434_ATTACHMENT G.X - Ellington AFB (EF) AF3000.pdf PDF
ESBD_371089_1723063135331_ATTACHMENT G.Q - Ellington AFB (EF) Cutting And Patching.pdf PDF
ESBD_371089_1723062848141_ATTACH~2.PDF PDF
ESBD_371089_1723062652487_ATTACHMENT G.H - Ellington Field (EF) EMS Environmental Protection.pdf PDF
ESBD_371089_1723062537933_ATTACHMENT G.F.2 - Ellington AFB (EF) Contractor Hazardous Material Identification Form Close-Out Procedures.pdf PDF
ESBD_371089_1723063316199_ATTACH~3.PDF PDF
ESBD_371089_1723063367434_ATTACHMENT G.X - Ellington AFB (EF) AF3000.pdf PDF
ESBD_371089_1723654956338_ESBD Addendum 1 - TMD24-ANG-WJ-24150009.pdf PDF
ESBD_371089_1723063015395_ATTACHMENT G.P - Ellington Field (EF) Contract Closeout.pdf PDF
ESBD_371089_1723062377226_ATTACHMENT G.E - Ellington Field (EF) Safety Policies And Procedures.pdf PDF
ESBD_371089_1723062990834_ATTACHMENT G.O - Ellington Field (EF) Starting Of Systems.pdf PDF
ESBD_371089_1723063177299_ATTACHMENT G.S - Ellington AFB (EF) Substitutions Request Form.pdf PDF
ESBD_371089_1723062041430_ATTACHMENT G.7 Trench Details.pdf PDF
ESBD_371089_1723062454062_ATTACHMENT G.F - Ellington Field (EF) EMS Hazardous Material Procedures.pdf PDF
Show 40 more

Latest 50 of 77 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ATTACHMENT G.N - ELLINGTON AFB (EF) MANUFACTURERS’

SERVICES

PART 1 – GENERAL

1. DEFINITIONS

Person-Day: One person for eight (8) hours within regular Contractor working hours.

2. SUBMITTALS

A. Training Schedule: Submit not less than twenty-one (21) days prior to start of equipment installation and revise as necessary for acceptance.

B. Preliminary Training Plan: Submit within sixty (60) days after Notice to Proceed for approval by the Project Manager.

C. Final Training Plan: Submit after training coordination meeting.

D. Training Materials:

a. Submit written outlines of proposed training sessions not less than twenty-one

(21) days prior to scheduled training to be approved by the Project Manager.

b. Furnish complete training materials, to include operation and maintenance data as required in this section to be retained by each trainee.

E. Quality Control Submittals: When specified in the individual Specifications, submit:

a. Qualifications of Manufacturer’s Representative performing specified services.

b. Manufacturer’s Certificate of Proper Installation: On form appended to this section.

3. QUALIFICATION OF MANUFACTURER’S REPRESENTATIVE

A. Authorized representative of the manufacturer shall be factory trained and experienced in the technical applications, installation, operation, and maintenance of respective equipment, subsystem, or system. Additional qualifications may be specified elsewhere.

B. Manufacturer’s Representative subject to acceptance by the Project Manager. No substitute representatives will be allowed unless prior written approval by the Project

Manager has been given.

4. FULFILLMENT OF SPECIFIED MINIMUM SERVICES

A. Where manufacturers’ services are specified, furnish manufacturer’s qualified representative. Where time is necessary in excess of that stated in the Specifications for manufacturers’ services, additional time required to perform the specified services shall be considered incidental work.

B. Schedule manufacturer’s services to avoid conflicting with other onsite testing or other manufacturer’s onsite services.

a. Determine that all conditions necessary to allow successful testing have been met before scheduling services.

C. Only those days of service approved by the Project Manager will be credited to fulfill the specified minimum services.

D. If specified, manufacturer’s onsite services shall include as a minimum:

a. Assistance during product (system, subsystem, or component) installation to

ELLINGTON FIELD, HOUSTON, TX 21 May 2024 include observation, guidance, instruction of Contractor’s assembly, erection, installation or application procedures.

b. Inspection, checking, and adjustment as required for product (system, subsystem, or component) to function as warranted by manufacturer and necessary to furnish written approval of installation.

c. Revisiting the site as required to correct problems and until installation and operation are acceptable to the Project Manager.

d. Resolution of assembly or installation problems attributable to, or associated with, respective manufacturer’s products and systems.

e. Assistance during functional and performance testing and startup demonstration, and until product acceptance by the Project Manager.

f. Training of EF personnel in the operation and maintenance of respective product as required.

g. Completion of Manufacturer’s Certificate of Proper Installation (form enclosed at end of this section) with applicable certificates for proper installation and initial, interim, and final test or service.

h. Additional requirements as may be specified elsewhere.

5. TRAINING SCHEDULE

A. List specified equipment and systems with respective manufacturers that require training services of manufacturers’ representatives and show:

a. Estimated dates for installation completion.

b. Estimated training dates to allow for multiple sessions when several shifts are involved.

B. Adjust training schedule to ensure training of appropriate personnel as deemed necessary by the Project Manager, and to allow full participation by manufacturers’ representatives. Adjust schedule for interruptions in operability of equipment.

6. TRAINING PLAN

A. Preliminary Training Plan: If specified, and within sixty (60) days after Notice to

Proceed, submit for each proposed course to be approved by the Project Manager:

a. Title and objectives.

b. Training schedule.

c. Prerequisite training and experience of attendees.

d. Recommended types of attendees (e.g., managers, engineers, operators, maintenance).

e. Course description and outline of course content.

f. Duration.

g. Location (e.g., training center or site).

h. Format (e.g., lecture, self-study, demonstration, hands-on).

i. Instruction materials and equipment requirements.

j. Final Training Plan: Submit the following after training coordination meeting, if specified.

k. Updated versions of course descriptions from preliminary training plan.

l. Personnel who will attend each course.

ELLINGTON FIELD, HOUSTON, TX 21 May 2024

m. Schedule of training courses including dates, durations, and locations of each class.

n. Detailed course schedule for each day showing time allocated to each topic.

o. Resumes of instructors providing the training.

7. TRAINING BASE PERSONNEL

A. Furnish trained, articulate personnel to coordinate and expedite training, to be present during training coordination meetings with EF Personnel, and familiar with operation and maintenance manual information specified in Division 1 Section, “Operation and

Maintenance Data”.

B. Furnish manufacturers’ representatives for detailed classroom and hands-on training to EF personnel on operation and maintenance of specified product (system, subsystem, component) and as may be required in applicable Specifications.

a. Manufacturer’s Representative: Familiar with facility operation and maintenance requirements as well as with specified equipment.

C. Prestart up Training:

a. Coordinate training sessions with EF operating personnel and manufacturers’ representatives, and with submission of operation and maintenance manuals in accordance with Division 1 Section “Operation and Maintenance Data”.

b. Complete at least fourteen (14) days prior to actual startup.

D. Post-Startup Training: If required in Specifications, furnish and coordinate training of

EF operating personnel by respective manufacturer’s representatives.

8. SUPPLEMENTS

A. The supplements listed below, following “END OF SECTION,” are part of this

Specification.

a. Forms: Manufacturer’s Certificate of Proper Installation.