This document is a construction drawing set for a federal project at Stratton VA Medical Center. The project involves the design and renovation of an Interventional Radiology-Cardiac Catheterization Laboratory within the hospital facility. The drawing represents 100% Construction Documents dated July 9, 2025, and depicts the First Floor Plan with a fully sprinklered design. The project is located in Stratton, New York, and is under the jurisdiction of the U.S. Department of Veterans Affairs, Office of Construction and Facilities Management.

The architectural and engineering documents are prepared by Hyman Hayes Engineering LLP (Albany, NY) in conjunction with FE LLP (Middletown, NY), with Project Number 20-373 and Drawing Number 528A8-18-801. The plan illustrates the layout of Wings A, B, C, and D, along with the core structure, showing room configurations, structural elements (including various W-beam designations), and an enlarged conduit view for electrical infrastructure. The document includes standard construction document notations and professional stamps from the Architect/Engineer of Record, indicating this is a formal, federally-prepared construction document ready for project implementation.

View the file

Other files

File Type Posted
36C24226R0033 0014.docx DOCX document
SUBBASEMENT soil removal path.pdf PDF
36C24226R0033 0013.docx DOCX document
36C24226R0033 0012.docx DOCX document
36C24226R0033 0011.docx DOCX document
VA Design Manual.pdf PDF
Cath Lab Concept View.pdf PDF
Stratton VA Interior Finish Standards-250613.pdf PDF
ES-100 clarification spoils earth removal R1.pdf PDF
36C24226R0033 0010.docx DOCX document
IR Lab Concept View.pdf PDF
36C24226R0033 0009.docx DOCX document
0338 VA RFI-002 03-19-26f.pdf PDF
36C24226R0033 0008.docx DOCX document
36C24226R0033 0007.docx DOCX document
EXHIBIT C - Past Performance Questionnaire V1.docx DOCX document
36C24226R0033 0006.docx DOCX document
36C24226R0033 0005.docx DOCX document
EXHIBIT C - Past Performance Questionnaire.docx DOCX document
36C24226R0033 0004.docx DOCX document
EXHIBIT B - Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx DOCX document
36C24226R0033 0003.docx DOCX document
Walkthrough sign in sheet.pdf PDF
2-11-26 - Stratton VAMC Cath Lab 528A8-18-801 - Volume One 100 Percent CD Specifications.pdf PDF
12-05-25 - VA STRATTON CARDIAC CATH - 100pct SnS.pdf PDF
2-11-26 - Stratton VAMC Cath Lab 528A8-18-801 - Volume Two 100 Percent CD Specifications.pdf PDF
36C24226R0033 0002.docx DOCX document
36C24226R0033 0001.docx DOCX document
ES-402 ADDENDUM 1.pdf PDF
7-9-25 - VA STRATTON CARDIAC CATH 100 CD SUBMISSION v2.pdf PDF
WD Albany.docx DOCX document
36C24226R0033_1.docx DOCX document
GI-004 ADDENDUM 1.pdf PDF
ES-401 ADDENDUM 1.pdf PDF
Stratton VAMC Cath Lab 528A8-18-801- Volume Two 100 CD Specifications.pdf PDF
Stratton VAMC Cath Lab 528A8-18-801 - Volume One 100 CD Specifications.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2H R

2HR

2HR

2HR

2HR2HR

2HR

2HR2H

R

2H R

2H R

2H R

2H R

2HR

2HR

2HR 2H

R

2H R

2H R

2H R

2HR

2HR

2H R

2H R

2H R

Change Baby

SW3

B103 A135c

100e

100b

100a

100f

100h

100f

138-1

IT

A137

100c

W

W

W

W

W

W

W12 W12W16

W

W

W

W

W12 W12 W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12

W12W12 W12

W

W 21W

W

W12 W12 W12

W21 W21

W21

W21

W16

W10

W16

W10

W

X2

W

X2

W12 W

W8

W12

W10

W10

W10

W10

W10

HYMAN

HAYES

ASSOCIATES

800 TROY-SCHENECTADY

ROAD, STE 103

LATHAM, NY 12110

(518) 452-3470 www.hymanhayes.com

ENGINEERING LLP

FE PROJECT NO: 20-373

22 Mulberry St., Suite 2A, Middletown, NY 10940 t 845-343-1481; fx 855-320-8735

181 Church St., Suite 100, Poughkeepsie, NY 12601 t 845-454-9704; fx 855-320-8735 www.fellp.com

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

6/

/2

:3 9:

P

M

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

PhaseARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT

321 4 5 6 7 8 9 10

528A8-18-801

Project Director

07-09-2025 CC / JDFRevisions: Date:

STRATTON VA MEDICAL CENTER

DESIGN RENOVATE FOR IR-CARDIAC CATH100% CONSTRUCTION DOCUMENTS

SRB

PROJECT

NORTH

KEY PLAN

CORE

WING 'C'

WING 'B' WING 'A'

WING 'D'

FIRST FLOOR PLAN (SHOWN FOR REFERENCE)1

NOTES:

ENLARGED CONDUIT VIEW2

AutoCAD SHX Text

OUTLINE OF IR SUITE ABOVE

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

OUTLINE OF CATH SUITE ABOVE

AutoCAD SHX Text

PM

AutoCAD SHX Text

PM

AutoCAD SHX Text

PM

AutoCAD SHX Text

JOHN D. FELLENZER, P.E.

AutoCAD SHX Text

NY PROFESSIONAL ENGINEER NO. 069373-1

AutoCAD SHX Text 113 Holland Ave, Albany, NY 12208

AutoCAD SHX Text E

AutoCAD SHX Text X

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text

ELECTRICAL: FIRST FLOOR PLAN + PARTIAL BASEMENT/FIRST FLOOR CHASE PLANS

AutoCAD SHX Text

1-ES-100A

AutoCAD SHX Text

SCALE: 1/4"=1'-0"

AutoCAD SHX Text

1. ALL "UNDER FLOOR" RACEWAYS FOR IR AND CATH SYSTEMS ALL "UNDER FLOOR" RACEWAYS FOR IR AND CATH SYSTEMS SHALL RUN BELOW 2ND FLOOR SLAB IN 1ST FLOOR CEILING SPACE. CEILING SPACE HAS EXISTING PIPES, CONDUITS, CABLE TRAYS, ETC. BUT IS GENERALLY CLEAR EXCEPT FOR OBSTRUCTIONS SHOWN. FINAL ROUTING OF UNDER FLOOR RACEWAYS SHALL BE DETERMINED BY CONTRACTOR BASED ON DRAWINGS PROVIDED BY SYSTEM MANUFACTURERS. 2. CALLOUTS REFER TO RACEWAY SCHEDULE ON DRAWING CALLOUTS REFER TO RACEWAY SCHEDULE ON DRAWING 1-PH-009 AND 1-PH-020. 3. CALLOUT - PROVIDE 3" CONDUIT FOR USE BY OWNER FOR CALLOUT - PROVIDE 3" CONDUIT FOR USE BY OWNER FOR PATIENT MONITORING SYSTEM.

AutoCAD SHX Text

SHADING INDICATES N.I.S. AREA ABOVE

AutoCAD SHX Text

AutoCAD SHX Text

SCALE: 1/2"=1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

ES-100A

AutoCAD SHX Text

PM

AutoCAD SHX Text

PATIENT MONITORING SYSTEM

AutoCAD SHX Text 8/5/25

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text