ES-100 clarification spoils earth removal R1.pdf

PDF 63 KB Posted

Attached to
Z1DA--NRM CONSTRUCTION -528A8-18-801 Renovate for Cardiac Cath & IR
Solicitation number
36C24226R0033
Issued by

About this file

This is an architectural plan drawing for a Partial Sub-Basement Floor Power and Communications installation. The plan depicts the layout of a sub-basement level with designated areas for new power and communications infrastructure, shown in green shading across the drawing. The plan indicates new crawl space walkways, new 4-inch conduits for power distribution, and new signal conduits. Existing infrastructure is marked in red, including existing steam and chilled water pipes along the wall, existing ductwork, and existing 17-pair cable routing from Building 14 to 522. The drawing shows Room 522 and Room 521 in the upper portion, with a new crawl space area highlighted along the main corridor. Multiple conduit boxes are scattered throughout the floor plan, indicating electrical connection points. A general note specifies that all conduit and boxes in crawl space shall be installed in sub-basement electrical rooms or corridor areas as permitted by existing conditions, and directs removal and disposal of all excavated materials. The plan scale is shown as 1/4"=1'-0" and includes a reference circle marked as drawing number 1.

View the file

Other files

File Type Posted
36C24226R0033 0014.docx DOCX document
SUBBASEMENT soil removal path.pdf PDF
36C24226R0033 0013.docx DOCX document
36C24226R0033 0012.docx DOCX document
36C24226R0033 0011.docx DOCX document
Cath Lab Concept View.pdf PDF
IR Lab Concept View.pdf PDF
VA Design Manual.pdf PDF
Stratton VA Interior Finish Standards-250613.pdf PDF
36C24226R0033 0010.docx DOCX document
0338 VA RFI-002 03-19-26f.pdf PDF
36C24226R0033 0009.docx DOCX document
36C24226R0033 0008.docx DOCX document
EXHIBIT C - Past Performance Questionnaire V1.docx DOCX document
36C24226R0033 0007.docx DOCX document
36C24226R0033 0006.docx DOCX document
36C24226R0033 0005.docx DOCX document
EXHIBIT C - Past Performance Questionnaire.docx DOCX document
36C24226R0033 0004.docx DOCX document
EXHIBIT B - Sample Transmittal Letter for Past Performance Evaluation Questionnaire.docx DOCX document
Walkthrough sign in sheet.pdf PDF
36C24226R0033 0003.docx DOCX document
2-11-26 - Stratton VAMC Cath Lab 528A8-18-801 - Volume One 100 Percent CD Specifications.pdf PDF
36C24226R0033 0002.docx DOCX document
2-11-26 - Stratton VAMC Cath Lab 528A8-18-801 - Volume Two 100 Percent CD Specifications.pdf PDF
12-05-25 - VA STRATTON CARDIAC CATH - 100pct SnS.pdf PDF
36C24226R0033 0001.docx DOCX document
7-9-25 - VA STRATTON CARDIAC CATH 100 CD SUBMISSION v2.pdf PDF
36C24226R0033_1.docx DOCX document
Stratton VAMC Cath Lab 528A8-18-801- Volume Two 100 CD Specifications.pdf PDF
ES-100A ADDENDUM 1.pdf PDF
ES-402 ADDENDUM 1.pdf PDF
WD Albany.docx DOCX document
Stratton VAMC Cath Lab 528A8-18-801 - Volume One 100 CD Specifications.pdf PDF
GI-004 ADDENDUM 1.pdf PDF
ES-401 ADDENDUM 1.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PARTIAL SUB-BASEMENT FLOOR POWER AND COMMUNICATIONS PLAN1

GENERAL NOTE:

VHAALNHoganJ Polygon

VHAALNHoganJ Callout existing

VHAALNHoganJ Polygon

VHAALNHoganJ Polygon

VHAALNHoganJ Callout New spoils / earth removals