HSHQDN-17-R-0002
REQUEST FOR PROPOSAL – ATTACHMENT 2
Radiation Portal Monitor System Requirements
In support of the Domestic Nuclear Detection Office (DNDO) RFP #HSHQDN-17-R-0002, below are the Government’s requirements for the Radiation Portal Monitor (RPM) system.
Background: The Request for Proposal (RFP) consists of the Operational and Functional requirements that define the operational and functional capability of the system. The Cybersecurity requirement group defines the essential cybersecurity requirements that a RPM Replacement system must achieve to provide baseline cybersecurity capabilities and support secure operation of the RPM Replacement on the U.S. Customs and Border Protection’s (CBP) network. The cybersecurity requirements are modeled after the NIST SP 800-53 controls and in a few cases modifications have been made in order to meet CBP’s needs for the RPM Replacement system.
The document is divided into the following groups of requirements:
Operational and Functional Requirement Groups
| 1. Applicability |
| 8. Capacity |
| 15. Law Enforcement Suitability |
| 2. Nuclear Detection Capability |
| 9. Physical Interoperability |
| 16. Cybersecurity |
| 3. Radiological Detection Capability |
| 10. Manpower |
| 17. Availability |
| 4. Discrimination |
| 11. Network Interoperability |
| 18. Maintainability |
| 5. Selectivity |
| 12. Survivability |
| 19. Training |
| 6. Flexibility |
| 13. Safety |
| 7. Noise Tolerance |
| 14. Human Factors |
The requirements consist of operational requirements (marked as OR), which indicate the operational needs of the Government, and related functional requirements (marked as FR). A subset of these requirements is considered key performance parameters (KPPs) and, as such, are those requirements deemed essential or critical for an effective system. DNDO is providing this information so that Offerors may have a better understanding of the totality of characteristics that DNDO values in a system.
Requirement Group 1 – Applicability For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarification |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-01 |
| None |
| The system shall accommodate Federal Highway Administration scheme F Class I to Class 13 conveyances (KPP). |
| System configurable to accommodate conveyances up to 162 inches high by 108 inches wide plus a maximum of 7 inches on each side for the side mirrors of conveyances. |
| Same as Threshold. |
| None |
| X |
| RPM-FR-01 |
| None |
| The RPM shall detect a conveyance traversing the portal detection zone. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-03 |
| None |
| The RPM shall detect and account for each conveyance in its detection zone only once. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-14 |
| None |
| The RPM shall indicate a fault when the conveyance occupies the detection zone longer than the operator set occupancy duration threshold of at least 600 seconds. |
| Requirement met = yes |
| Same as Threshold |
| This functionality is for the operator to measure stationary objects in the detection zone with a variable occupancy time of up to 600 seconds. |
| RPM-FR-424 |
| None |
| The RPM shall have the functionality to generate at least 10,000 consecutive artificial occupancies, where the system software is generating the start and end of the occupancy in place of the occupancy sensor. |
| Requirement met = yes |
| Same as Threshold |
| Can be used to determine false alarm rate in the presence of background only. |
| RPM-FR-450 |
| None |
| The RPM shall allow an operator to execute the artificial occupancy functionality. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-11-1 |
| None |
| The RPM shall automatically assign a unique sequential occupancy index number, the occupancy index, to each sequential occupancy. |
| Requirement met = yes |
| Same as Threshold |
| The RPM can utilize a time/date stamp as part of the assigned occupancy index numbers. |
| RPM-FR-121 |
| None |
| The control console shall display and reference all occupancy records (FR-429) by Occupancy Index and Lane ID numbers. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-11-4 |
| None |
| The Occupancy Index shall be maintained, and not reset, through complete loss of power. |
| Requirement met = Yes |
| Same as Threshold |
| Both internal and external power. |
| RPM-FR-258 |
| None |
| The RPM Station ID shall be an American Standard Code for Information interchange (ASCII) character string at least 10 characters in length that identifies the lane. |
| Requirement met = yes |
| Same as Threshold |
| The Station ID is a unique code for each POE lane across the nation set by the Government. |
| RPM-FR-20-1 |
| None |
| The RPM shall record the direction of the conveyance during an occupancy. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-01a |
| None |
| The system shall include a configuration that accommodates over-size load conveyances. |
| Configurable to accommodate over-size load conveyances up to 192 inches wide and 192 inches high in special lanes. (Average over-size load permit limits issued by states). |
| Same as Threshold |
| None |
| RPM-FR-72 |
| None |
| The wide load configurations of the RPM shall be composed of the same Line Replaceable Units (LRUs) as a standard configuration of the RPM. |
| Requirement met = yes |
| Same as Threshold |
| The wide lane system will use the same LRUs, not the same configuration, or number, of those LRUs. |
HSHQDN-17-R-0002
Requirement Group 2 – Nuclear Detection Capability Notes:
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-06 |
| None |
| The system shall detect the presence of nuclear threats and materials in conveyances undergoing scanning (KPP). |
Note: See Glossary for the definition of detect.
| System’s detection performance of the threat likelihood has statistically-significant equivalence to that of the currently-deployed technology. |
| System’s detection performance of the threat likelihood has statistically-significant improvement to that of the currently-deployed technology. |
| None |
| X |
| RPM-FR-64 |
| None |
| The system shall refer conveyances containing the presence of nuclear threats and materials in conveyances undergoing scanning, either with correct or incorrect categorization. |
| X% of threat likelihood detected. |
Y% of threat likelihood detected.
<NORM> categorization of nuclear threats and materials will be considered a failure to refer under this requirement.
| RPM-FR-58 |
| None |
| The RPM shall categorize and refer an occupancy as <Neutron> when neutron radiation is detected at levels above the neutron threshold. |
| 177 out of 180 occupancies per Test Method 6.4.2 of ANSI N42.38 2015. |
| Same as Threshold |
| This requirement shall be tested when exposed to a Cf-252 neutron source with an emission rate of 20,000 n/s. |
Requirement Group 3 – Radiological Detection Capability Notes:
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-06a |
| None |
| The system shall detect the presence of radiological materials that pose a potential threat or health risk, in conveyances undergoing scanning (KPP). |
| Detect these materials, under “unshielded” conditions: |
Am-241: 47 μCi Co-60: 7 μCi Cs-137: 16 μCi Ir-192: 6 μCi Sr-90: 750 μCi, with 1 cm steel shielding.
In addition to the threshold, detect shielded Am-241, Co-60, Cs-137, Ir-192, Sr-90, Pu-238, Se-75, and Yb-169 emitting no more than 200,000 photon/s, where the ratio of the number of photons in the primary photo peak to total photon emission is 1/10th or less of that ratio in a bare configuration.
| Note: Ir-192 and Sr-90 are in addition to the radionuclides listed in Table 4 of ANSI 42.38-2015. |
| X |
| RPM-FR-421-1 |
| None |
| The RPM shall have a linear, adjustable referral threshold, equivalent to a linear gross count rate threshold, that has a range covering net gamma fluxes from 0.72 Gamma-photons/cm2 per second to Threshold: 16.92 Gamma-photons/cm2 per second; Objective 33.84 |
Gamma-photons/cm2 per second.
| Range covering net gamma fluxes from 0.72 Gamma-photons/cm2 per second to 16.92 Gamma- photons/cm2 per second. |
| Range covering net gamma fluxes from 0.72 Gamma-photons/cm2 per second to 33.84 |
Gamma-photons/cm2 per second.
The Threshold may use any measurable units as long as they are linear to the amount of radiation impacting the sensors of the RPM. A linear, proportional threshold based on the standard deviation of the background radiation is acceptable if it covers the net radiation flux ranges specified. The net radiation fluxes provided are for a theoretical spherical surface 196 cm from the source after subtraction of the background radiation.
| RPM-FR-421-2 |
| None |
| The RPM gross count rate threshold (FR-421-1) shall refer any source regardless of categorization. |
| Requirement met = yes |
| Same as Threshold |
| None |
Requirement Group 4 – Discrimination
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-02a |
| None |
| The system shall categorize or identify specific radiation sources detected in conveyances. |
| Categorize radiation sources detected as neutron, nuclear, industrial, medical, NORM and unknown. |
Identify Radiation sources detected, listed in Appendix 1
Note: See nuclide category list in Appendix 1.
Note: Includes cases of spectral modification due to heavy shielding, e.g., requirement 6a (objective).
Note: See Glossary for definition of identify.
| RPM-FR-105-1 |
| None |
| All control consoles shall display the recognition of sensed radiation in an occupancy. |
| Display all the source(s) categorizations. |
| Display all the source(s) categorizations and identities. |
| None |
| RPM-FR-48 |
| None |
| The RPM shall properly categorize and refer sources within the specified energy range when the measured count rate is greater than the maximum background noise level. |
| Energy range: 30 keV to 3 MeV |
| Energy range: Starting range of 20 keV to |
3 MeV tested with Cd-109 The maximum background noise level is the value that the system assumes is the maximum level of Poisson distribution of the background radiation.
| RPM-FR-66-1 |
| None |
| Occupancies containing only sources defined as medical shall be correctly categorized as <Medical>. |
| Correctly categorized the occupancy at 90% at 80% confidence. |
| Correctly categorized the individual medical sources at 98% with 80% confidence. |
| <Medical> and <Industrial> sources are provided in Appendix 1. |
| RPM-FR-66-2 |
| None |
| Occupancies containing Industrial sources shall be correctly categorized as <Industrial>. |
| Correctly categorized 90% at 80% confidence. |
| Correctly categorized 98% at 80% confidence. |
| <Medical> and <Industrial> sources are provided in Appendix 1. |
| RPM-FR-69 |
| None |
| Occupancies that contain a source of radiation, above the maximum background noise level, that cannot otherwise be positively categorized shall be categorized as <Unknown> and referred to secondary. |
| Requirement met = yes |
| Same as Threshold |
| Sources above background noise level. |
| RPM-FR-83 |
| None |
| The RPM shall correctly categorize occupancies containing radiation sources, such as those listed in OR-06, OR-06a, when the background radiation counts are suppressed by 15 to 50% due to shielding effects. |
| Requirement met = yes |
| Same as Threshold |
| None |
Requirement Group 5 – Selectivity
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-08 |
| None |
| The system shall avoid nuisance alarms by recognizing, and not referring for additional inspection, cargo conveyances containing only NORM cargo (KPP). |
Note: See Glossary for the definition of nuisance alarm and recognize.
Clarification: Using operational settings selected to meet Requirement #6.
Referral of no more than 1% of NORM cargos comprised of unshielded K-40, Th-232, and Ra-226 materials, at and above a flux of 0.93 photons/cm2 -sec.
Note: Flux measured at the “hot spot” at the exterior bounds of a cargo conveyance 8-feet wide facing the detector along the path of travel.
Referral of no more than 0.1% of NORM cargos where the photon signals are discernable from noise (i.e., signal to noise ratio greater than 1).
Clarification: If a system can detect the signal from the NORM source at the settings used to meet Requirement #6, it shall recognize it.
| Using operational settings selected to meet OR-06. |
| X |
| RPM-FR-65-1 |
| None |
| The RPM shall correctly recognize and categorize occupancies containing NORM cargo with flux from materials containing K-40. |
| Correctly categorize 99% (at 70% confidence) cargos with K-40 emitting a flux of at least 0.93 +/-0.05 Gamma-photons/cm2 per second at 122 cm. |
| Correctly categorize 99.9% (at 70% confidence) NORM cargos that include K-40, emitting no more than 0.93 Gamma-photons/cm2 per second. |
| (Threshold is equivalent to ten 50 lbs. bags of potassium chloride based ice melt oriented with the long edge along the travel path, stacked in two columns of five with a Minimum Net Emission Rate (MNER) of 8.49 μR/hr measured at the top of each bag.) |
| RPM-FR-65-2 |
| None |
| The RPM shall correctly recognize and categorize occupancies containing NORM cargo with flux from materials containing Ra-226 and daughters. |
| Correctly categorize 99% (at 70% confidence) cargos containing Ra-226 that is emitting a flux of at least 0.93 +/- 0.05 Gamma-photons/cm2 per second at 122 cm |
| Correctly categorize 99.9% (at 70% confidence) NORM cargos that include Ra-226, emitting no more than 0.93 Gamma-photons/cm2 per second total. |
| (Threshold is equivalent to three 50 lbs. of zircon sand oriented with the short edge to the travel path with a MNER of 80.7 μR/hr measured at the top of each bag.). |
| RPM-FR-65-3 |
| None |
| The RPM shall correctly recognize and categorize occupancies containing NORM cargo with flux from materials containing Th-232. |
| Correctly categorize 99% (at 70% confidence) cargos containing Th-232 that is emitting a flux of at least 0.93 +/- 0.05 Gamma-photons/cm2 per second at 122 cm radius. |
| Correctly categorize 99.9% (at 70% confidence) NORM cargos that include Th-232, emitting no more than 0.93 Gamma-photons/cm2 per second total. |
| (Equivalent to six hundred 2% thorium welding rods (3.2 mm dia) lying flat in three boxes stacked the floor of the container with a MNER of 153 μR/hr per box.). |
| RPM-FR-444 |
| None |
| The system shall detect and refer ionizing radiation sources when the conveyance also contains NORM. |
| Masking ratio of 1:1 referred by categorizing example ionizing radiation sources (OR-6a Threshold) included with NORM cargo as any category other than <NORM>. |
| Masking ratio of 5:1 referred by categorizing example ionizing radiation sources (OR-6a Objective) included with NORM cargo as <Unknown> or per the Isotope List. |
| The masking ratio is defined as the total photons from NORM material to the total photons from the nuclear material. Total photons are integrated over energy range of 65 keV to 3 MeV. |
Requirement Group 6 – Flexibility
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-3 |
| None |
| The system shall allow managers to modify/update the signature parameter settings (objects, radionuclides, categories, alarm settings, etc.) that the system uses to recommend referral for additional inspection or release. |
| Update locally (at/from the POE) via system software interface and remotely (e.g., via CBP network). |
| Same as Threshold |
| None |
| RPM-FR-380 |
| None |
| The RPM control console shall allow managers to modify all recognition process parameters used to detect, recognize, categorize and determine referral or release of radiation sources. |
| Locally and remotely |
| Same as Threshold |
| Parameters include: |
1) The category for any recognized radiation signature;
2) Any gross count referral (alarm) threshold;
3) Referral (alarm) criteria;
4) Recognition process parameters.
| RPM-FR-247 |
| None |
| The supervisor control console shall allow a manager to set parameters for each RPM independent of other RPM(s) at the site. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-249 |
| None |
| The supervisor control console shall allow a manager to set parameters for all RPM(s) at a site at once. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-449 |
| None |
| The RPM shall allow managers to modify all software libraries used in the recognition process. |
| Locally and remotely |
| Same as Threshold |
| The recognition process includes categorization. |
| RPM-FR-09 |
| None |
| The RPM shall allow remote and local managers to control: |
1) System hardware parameter settings;
2) Event log parameter settings;
3) Background collection parameter settings;
4) Calibration settings or calibration validation function;
5) Network settings.
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-448 |
| None |
| The RPM shall provide information to remote and local managers: |
1) System hardware parameter setting values;
2) Event log;
3) Gamma background energy spectral history;
4) Calibration values;
5) Calibration date;
6) User system access history.
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-230 |
| None |
| The RPM shall support the change (local and remotely) of any recognition parameters without changing the recognition process until the changed parameters are implemented. |
| Requirement met = yes |
| Same as Threshold |
| When parameters are changed, the RPM is expected to still be in operation such that the RPM software will need to implement a new set of parameters after a complete setup of those operating parameters. |
| RPM-FR-251-2 |
| None |
| The control console(s) (local and remote) shall allow managers to configure each RPM identity. |
| RPM identity : |
1) Site ID;
2) Lane ID;
3) Station ID.
RPM identity :
1) Site ID;
2) Lane ID;
3) Station ID;
4) LRU ID.
None
| RPM-FR-251-1 |
| None |
| The RPM shall allow managers to select between three preset parameter configurations stored on the RPM. |
| Requirement met = yes |
| Same as Threshold |
| None |
Requirement Group 7 – Noise Tolerance
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
Req. #
Variant
Requirement
Threshold
Objective
Clarifications
KPP
Meets (T or O) Does Not Meet
Reference/Explanation
| RPM-OR-05 |
| None |
| The system shall minimize the number of occupancies referred for additional inspection due to false alarms. |
Note: Refer to Glossary for the definition of false alarm.
| 0.1% or less of occupancies where no radiation above background is present. |
| 0.01% or less of occupancies where no radiation above background is present. |
| Using operational settings selected to meet Requirement 6. |
| RPM-FR-60 |
| None |
| Net Gamma Radiation exposure rates of up to 10mR hr (at the face center of the detection assembly) shall not result in a referral due to neutrons. |
| Meet ANSI N42.38 2015, Section 6.6.2 Test. |
| Same as Threshold |
| This is the gamma rejection requirement. |
Requirement Group 8 – Capacity
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-02 |
| None |
| The system shall provide the operator with an automated decision recommendation [indication] of need to conduct further inspection or allow release of a scanned conveyance. |
| Refer for additional inspection conveyances containing any radiation sources, except for non-licensable NORM sources. |
| In addition to Threshold, provide distinct indication of the presence of medical isotopes listed in Appendix 1. |
| None |
| RPM-FR-115-4 |
| None |
| All consoles, excepting consoles built into the RPM portal itself, shall visually and audibly indicate the referral from each monitored RPM. |
| Requirement met = yes |
| Same as Threshold |
| The RPM portal is defined as the components of the RPM required to be located on the vehicular lane for operation. |
| RPM-FR-115-5 |
| None |
| All consoles shall visually indicate the release of an occupancy. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-116 |
| None |
| All consoles shall have positive user interaction to acknowledge referrals, acknowledge fault indicators and silence audible indicators. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-07 |
| None |
| The system shall quickly complete the scan of a conveyance. |
| Throughput of conveyances, to include scan and notification of refer-or-release recommendation, at a rate of 120 conveyances or greater per hour. (Based on a 73-foot total length of truck + conveyance combination.) |
| Throughput of conveyances, to include scan and notification of refer-or-release recommendation, at a rate of 180 conveyances or greater per hour. (Based on a 73-foot total length of truck + conveyance combination.) |
| None |
| RPM-FR-91 |
| None |
| The RPM shall record, or transmit, a complete occupancy record to a storage location on the Government network within 2 seconds of the vehicle exiting the detection zone. |
| Requirement met = yes |
| Same as Threshold |
| A complete occupancy record includes those items specified in FR-429. |
| RPM-FR-441 |
| None |
| The RPM shall transmit a complete referral or alarm response to the network within 3 seconds of a vehicle exiting the detection zone. |
| Transmit traffic control signals, Programmable Logic Controller (PLC) signals, and notifications to operating stations. |
| Same as Threshold |
| A complete referral shall consist of "Visual and audible indicators to all the RPM consoles monitoring the RPM, all electronic signals to traffic control equipment, all electronic signals to Program Logic Control systems. |
| RPM-FR-82 |
| None |
| The RPM shall categorize sources in conveyances that are changing speed in a range of (Threshold: 1 to 7 mph; Objective: 1 to 12 mph). |
| 1 to 7 mph |
| 1 to 12 mph |
| The requirement will be tested by passing through a source (that can be either shielded or bare) with an external emission of 0.93 +/- 0.05 Gamma-photons/cm2 per second at various entrance and exit speeds from 1 to 12 mph but not varying by more than 3 mph from entrance to exit. |
Requirement Group 9 – Physical Interoperability
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
Requirement
Threshold
Objective
Clarifications
KPP
Meets (T or O) Does Not Meet
Reference/Explanation
| RPM-OR-14 |
| None |
| The system shall operate in close proximity to pulsed, accelerator-based radioactive imaging systems. |
| Operate with no increased alarm rate or decreased detection efficiency at a distance of 150 feet from a radioactive imaging device. |
Note: Imaging systems intermittently will cause an increase of 50 µR/hr at a distance of 150 feet.
| Ability to operate side by side of a proximate imaging device. |
| None |
| RPM-FR-388 |
| None |
| The RPM shall be able to ignore radiation from nearby pulsed radiation imaging systems. |
| Radiation from nearby pulsed radiation imaging systems using sources from backscatter to 9 MeV. |
| Same as Threshold |
| None |
| RPM-OR-15 |
| None |
| The system shall be operable in multi-lane configurations without degradation in performance to Requirements RPM-OR-06, RPM-OR-6a and RPM-OR-08. |
| Operations/activities involving radioactive material in the surrounding area do not affect the appropriate referral or release decision. |
| Same as Threshold |
| None |
| RPM-FR-74 |
| None |
| At minimum the RPM should be shielded on the back and sides by the equivalent of 1 cm steel and 0.64 cm lead when measured using a source producing 1.5 MeV radiation. |
| Threshold: at least 1 cm steel and 0.64 cm lead (or equivalent at 1.5 MeV) |
| Objective: at least 1 cm steel and 1.28 cm lead (or equivalent at 1.5 MeV) |
| None |
| RPM-FR-25 |
| None |
| The RPM shall prevent background energy spectra, utilized by the recognition process, from being contaminated by sources in nearby conveyances. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-16 |
| None |
| The system shall physically conform to and operate within exit lanes at applicable U.S. POEs. |
| System fits and operates within existing exit lanes: 12.5 ft. wide, 10 ft. high for private vehicle lanes, 15 ft. high for truck lanes, 16 ft. wide and 16 ft. high for oversize load lanes. System foot print of 40 inches wide and 21 inches deep on each side of a lane, oversize load lanes are 82 inches wide and 21 inches deep (footprint of current systems). |
| Same as Threshold |
| None |
| RPM-FR-337 |
| None |
| The RPM shall be tolerant of power line noise, spikes, and fluctuations without interruption of operations. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-162 |
| None |
| The RPM shall switch automatically from main power to UPS power, when required, without operator action. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-164-1 |
| None |
| The RPM, when required, shall enter automatic shutdown to prevent damage when the UPS is near exhaustion. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-18 |
| None |
| The system shall be able to interface with peripheral equipment and traffic control equipment at Sea POEs. |
| Interfaces include: Programmable Logic Controller (PLC), Optical Character Recognition System, Visual Identification System cameras, intercom, and traffic control equipment. |
| Same as Threshold |
| None |
| RPM-FR-391 |
| None |
| Traffic controls shall operate automatically for occupancies that the RPM releases but require operator action when the occupancy is referred by the RPM. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-266 |
| None |
| The RPM shall be able to include at least four images per occupancy. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-93 |
| None |
| The RPM shall be able to communicate with a Programmable Logic Controller using an acceptable industrial protocol. |
| Requirement met = yes |
| Same as Threshold |
| Acceptable industrial protocols include: Ethernet/IP, Ethernet TCP/IP, Modbus TCP/IP and Profinet. |
| RPM-FR-94 |
| None |
| The RPM shall be able to configure 5-VDC TTL. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-51 |
| None |
| The RPM shall be unaffected by and capable of operating independently of any malfunction of a peripheral device. |
| Requirement met = yes |
| Same as Threshold |
| None |
Requirement Group 10 – Manpower
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-17 |
| None |
| The system shall be designed to operate as a single individual unit at the scanning site, as well as in a group of units operated remotely from a CBP command center. |
| Operator able to conduct all user/ operator tasks in Table 5 at the scanning site, primary inspection station booth, and remotely at sea POEs. |
Note: Sea POE remote operations to occur at CBP command centers located within the Sea POE or at regional centers.
| Same as Threshold |
| Table 5: |
| Place system/group of systems into operation, verify readiness to operate. |
Monitor system/group of systems during scanning operations.
Recognize and respond to system notifications, including system health and operational status.
Positively acknowledge and verify radiation alarm, including type of radiation.
Identify alarming lane and conveyance.
Route alarming conveyance to designated area for additional inspection. (Using traffic controls)
Dispatch secondary officer to resolve alarm.
Turn off the system.
Basic trouble-shooting: Includes reset system, confirm power to system components, confirm IT connectivity, and execute system diagnostics.
| RPM-FR-389 |
| None |
| All control consoles shall be able to perform the specified functions: |
1) Place the RPM into any operational modes;
2) Update the parameter settings for the RPM;
3) Verify that the RPM is in an operational mode;
4) Monitor the RPM occupancies;
5) Monitor VIS systems connected to the RPM;
6) Visually and audibly indicate each referral;
7) Allow the operator to positively acknowledge each referral;
8) Identify the alarming conveyance by occupancy number;
9) Operate traffic controls, when needed, to route conveyances for additional inspection;
10) Power up the RPM;
11) Power down the RPM;
12) Confirm power to (LRUs); 13) Confirm connectivity to RPM;
14) Confirm connectivity to peripherals;
15) Set the display configurations.
Requirement met = yes
| Same as Threshold |
| None |
| RPM-FR-390 |
| None |
| All supervisor control consoles shall be able to operate multiple RPMs. |
| Requirement met = yes |
| Same as Threshold |
| Capabilities to include: |
1) Place the RPMs into operational modes;
2) Update the parameter settings for each RPM;
3) Verify that each RPM is in an operational mode;
4) Display each RPM's occupancies;
5) Display VIS images in reference to the corresponding RPM monitored;
6) Visually and audibly indicate referrals with Gate ID and Lane ID;
7) Allow the operator to positively acknowledge referrals;
8) Identify the alarming conveyance by occupancy number, Gate ID, and Lane ID;
9) Operate traffic controls, when needed, to route conveyances for additional inspection;
10) Turn off the RPMs;
11) Reset each RPM;
12) Confirm power to (LRUs);
13) Confirm connectivity to each RPM;
14) Confirm connectivity to peripherals.
| RPM-FR-324 |
| None |
| Any monitor control console shall be able to become a supervisor control console for at least a single connected RPM upon manager instruction. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-54 |
| None |
| The RPM shall be operable, including storing data, after loss of communications on the government network. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-443 |
| None |
| The RPM shall automatically, without user interaction, retransmit all outstanding updates to the PRIDE update table after reconnection to PRIDE and the Government network. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-55 |
| None |
| The RPM shall be operable even after malfunction of a console. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-206-3 |
| None |
| The control consoles shall allow operators to query occupancy records for any connected RPM. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-237-1 |
| None |
| The control consoles shall allow operators to produce a file that contains RPM recognition process parameter settings. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-23 |
| None |
| The system shall minimize the manpower burden on CBP to operate at sea ports. |
| No more than one operator at a time is needed to operate the systems in 36 lanes. See Table 5 in Clarification of OR-17. |
| No more than one operator is needed to operate the systems in 67 lanes. See Table 5 in Clarification of OR-17. |
| None |
| RPM-FR-394 |
| None |
| All error visual indicator shall be trans illuminated and color coded such that all consoles shall use the same color for the same error and be provided in the documentation. |
| Requirement met = yes |
| Same as Threshold |
| Color coding of visual indicators: |
1) Red visual indicators are reserved for critical errors that prevent operation of the RPM;
2) Flashing red visual indicators are reserved for emergency conditions that require immediate user action to avert impending injury, equipment damage, or both. Note: On and off time flashing rate from three to five flashes per second;
3) Yellow visual indicators are reserved for errors that are not critical, allowing continued operation of the RPM in a degraded state;
4) Green visual indicators are reserved for values, conditions, etc. that are not in fault or outside operating parameters.
| RPM-FR-379-1 |
| None |
| All control consoles shall provide a graphical user interface for the operator to execute basic commands for each RPM. |
| Basic commands include: |
1) Acknowledgement of referrals;
2) Commands to traffic control equipment;
3) Acknowledgement of alarms;
4) RPM mode selection.
| Same as Threshold |
| This applies for all RPMs that are part of the portal monitoring site. |
| RPM-FR-379-2 |
| None |
| The supervisor control console shall provide a graphical user interface that directly associates a lane VIS image with the basic RPM commands, RPM error indicators, and RPM referrals or releases. |
| Requirement met = yes |
| Same as Threshold |
| This applies for all RPMs that are part of the RPM site. |
| RPM-FR-192 |
| None |
| All RPMs, consoles, and peripheral equipment connected to the network at a site shall be synchronized to a common accurate centralized time source. |
| No subsystem will deviate greater than +/- 0.01 seconds from the centralized source. |
| Same as Threshold |
| None |
| RPM-FR-237-2 |
| None |
| All consoles shall allow operators to select the basic operational modes of on or off for the RPM system. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-56 |
| None |
| The RPM shall be capable of transmitting status, and referral (alarm) signals to basic consoles at a distance of 50 m through hard wired connections. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-395 |
| None |
| The RPM shall be capable of providing power to hard wired basic consoles at a distance of 50 m. |
| Requirement met = yes |
| Same as Threshold |
| None |
Requirement Group 11 – Network Interoperability
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
See RFP Attachment 14, PRIDE ICD for additional requirements for the PRIDE Interface Control Document
Requirement
Threshold
Objective
Clarifications
| KPP |
| Meets |
(T or O) Does Not Meet
Reference/Explanation
| RPM-OR-09 |
| None |
| The system shall be compatible with CBP computer and Information Technology (IT) systems (KPP). |
| System IT component hardware and software meet the standard requirements definition for CBP's Technical Reference Model. |
| Same as Threshold |
| None |
| X |
| RPM-FR-381 |
| None |
| RPM occupancy, audit, and event records shall only be stored on a device or LRU that is accredited to be on and integrated into the CBP network. |
| Requirement met = yes |
| Same as Threshold |
| CBP Information System Security Officer must be able to push security network patches to the device. |
Comment: For additional CBP storage and memory policy and procedures, reference DHS Sensitive Systems Policy Directive 4300A.
Comment: To be accredited, a device’s information will have to be supplied to CBP to be approved as a component of the Technical Reference Model if not already listed there.
| RPM-FR-89 |
| None |
| For CBP network configuration, CBP OIT network support shall issue RPM network port Internet Protocol (IP) address, subnet mask, and default gateway. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-90 |
| None |
| The Transmission Control Protocol (TCP) port(s) shall be configurable (1024 through 65535). |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-92 |
| None |
| All networked hardware provided with the RPM shall be IPv6 compatible without modification, upgrade, or replacement. |
| Requirement met = yes |
| Same as Threshold |
| Applicability of Internet Protocol version 6 (IPv6) to DHS-related components (networks, infrastructure, and applications) specific to individual acquisitions shall be in accordance with the DHS Enterprise Architecture (per Office of Management and Budget Memorandum M-05-22, August 2, 2005). |
| RPM-FR-425 |
| None |
| The RPM shall have the ability to transfer data to an external device via Ethernet IPv6. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-382 |
| None |
| All Government networked RPM components, and other devices, shall communicate, or operate, with other network components operating Windows 7, Windows 10, and Win Server 2012. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-383 |
| None |
| All consoles with access to the CBP network shall show the CBP warning banner and require it to be accepted before user authentication. |
| Requirement met = yes |
| Same as Threshold |
| Note: Guidance as per DHS Sensitive Systems Policy Directive 4300A. |
| RPM-OR-10 |
| None |
| The system shall be interoperable with Port Radiation Inspection Detection and Evaluation (PRIDE) system. See RFP Attachment 14. |
| System complies with the PRIDE System Interface Control Document. |
Note: PRIDE is a National Information Exchange Model compliant system.
| Same as Threshold |
| None |
| RPM-OR-10a |
| None |
| The system shall be interoperable with Automated RPM Data Integration System (ARDIS). |
| System complies with the National Information Exchange Model. |
| Same as Threshold |
| ARDIS messages are included in RFP Attachment 14. |
| RPM-FR-100 |
| None |
| All transmitted data shall be formatted as per the RPM PRIDE Interface Control Documents (ICD) that include the N25 messaging protocols. |
| The basic messages properly formatted as described in the base RPM ICD document. |
| Same as Threshold |
| For each system there will be a specific interface control document promulgated post procurement and pre-deployment to communicate to PRIDE. |
| RPM-FR-179-2 |
| None |
| The RPM shall record, in either the event record or occupancy record database, all recognition process parameter settings and changes to the recognition process parameters, identified for FR-380, including time stamp, and lane ID. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-103-2 |
| None |
| All radiation data transmitted to PRIDE shall be in the Extensible Markup Language (XML) that meets ANSI N42.42 2012 requirements. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-426 |
| None |
| The manufacturer shall provide any proprietary software required for data interpretation. |
| Requirement met = yes |
| Same as Threshold |
| None |
Requirement Group 12 – Survivability
For any “Meets” indicate (T) Threshold or (O) Objective, where applicable. Variants:
None Key Performance Parameter:
“X”: This is considered a Key Performance Parameter.
If no “X” is listed, this is not a Key Performance Parameter.
| Req. # |
| Variant |
| Requirement |
| Threshold |
| Objective |
| Clarifications |
| KPP |
| Meets |
(T or O) Does Not Meet Reference/Explanation
| RPM-OR-26 |
| None |
| The system shall operate without degradation in all operational environments, including outdoor all-weather, electrical, electromagnetic (EM), and mechanical conditions. |
| ANSI N42.38, Sections 7 to 9, except the lower temperature limit is |
-40 °C. In Section 8, add the EM environment from Western Hemisphere Travel Initiative (WHTI) radio frequency identification (RFID) transceivers.
| Same as Threshold |
| None |
| RPM-FR-439 |
| None |
| Occupancy and speed sensors shall function in all environmental conditions specified. |
| Requirement met = yes |
| Same as Threshold |
| The occupancy and speed sensors shall be tested as part of the environmental testing and must operate without degradation to pass. |
| RPM-FR-440-1 |
| None |
| The RPM, in a standard configuration, shall be fully functional meeting all performance requirements over an ambient temperature range of -30 °C to 40 °C, per modified ANSI N42.38, Section 7.1.1 |
Note: Humidity levels should be low enough to prevent condensation (<75% RH) and the rate of change of temperature shall not exceed 10 °C per hour but may be less.
| Requirement met = yes |
| Same as Threshold |
| Standard configuration for normal ambient conditions include zones A3, B1, B2, and C1. |
| RPM-FR-440-2 |
| None |
| The RPM, to be qualified for cold climate applications, shall be fully functional meeting all performance requirements over an ambient temperature range of -40 °C to 40 °C, per modified ANSI N42.38, Section 7.1.1. |
Note: Humidity levels should be low enough to prevent condensation (<75% RH) and the rate of change of temperature shall not exceed 10 °C per hour.
| Requirement met = yes |
| Same as Threshold |
| To qualify an RPM configuration for cold climate conditions, including zone C2 MIL-STD-810G (2014), a system may be cooled, from the standard temperature range, to a temperature of -40 °C at a rate no greater than 10 °C per hour and soaked for 16 hours before checking for proper recognition of ANSI sources per N42.38 7.1.1. |
| RPM-FR-440-3 |
| None |
| The RPM, to be warm climate qualified, shall be fully functional meeting all performance requirements over an ambient temperature range of -30 °C to 55 °C, per modified ANSI N42.38, Section 7.1.1. |
Note: Humidity levels should be low enough to prevent condensation (<75% RH) and the rate of change of temperature shall not exceed 10 °C per hour.
| Requirement met = yes |
| Same as Threshold |
| To qualify an RPM configuration for warm climate conditions, including zones A1 and A2 per MIL-STD-810G (2014), a system may be heated from the standard temperature range to a temperature of +55 °C at a rate no greater than 10 °C per hour and soaked for 16 hours before checking for proper recognition of ANSI sources per N42.38 7.1.1. |
| RPM-FR-423 |
| None |
| The RPM shall have a non-operational mode that protects components for ambient environmental conditions, does not scan conveyances, does not record occupancies, monitors state of health, monitors background radiation, and can switch to an operational mode in less than 30 seconds. |
| Requirement met = yes |
| Same as Threshold |
| Clarification: For example, for protection against ambient environmental conditions, PVT sensors will be maintained above 0 °C. |
| RPM-FR-332 |
| None |
| The RPM shall be able to operate during and after exposure to RH levels of up to 93% at an ambient temperature of +40 °C, per ANSI N42.38, Section 7.2.1. |
Note: The minimum acceptable test value is 40% RH per ANSI N42.35, for standard Radiation Portal Monitors.
| Requirement met = yes |
| Same as Threshold |
| There shall not be any observable effect from the exposure to relative humidity for any of the RPM ambient temperature climate configurations. |
| RPM-FR-412-1 |
| None |
| The enclosure of the RPM, including any external LRUs, shall be undamaged from freezing rain, sleet, and snow. |
| Passes the External Icing Test National Electrical Manufacturers Association 250-2003 5.6.1. |
| The enclosure has no external cavities to trap water when mounted in the normal position (NEMA 250-2003 5.6). |
| None |
| RPM-FR-412-2 |
| None |
| The enclosure(s) of the RPM, including any external LRUs, shall not allow water under hose down conditions to penetrate. |
| Passes hose down test for NEMA 250-2003 5.7.1. |
| Same as Threshold |
| None |
| RPM-FR-412-3 |
| None |
| The gaskets of the RPM enclosure shall not deteriorate, deform, melt, crack, or harden after exposure to temperatures above 69 °C for multiple days. |
| Gasket maintains a tensile strength of no less than 75% and an elongation of not more than 60% after exposure to 70 °C for 168 hours. |
| Same as Threshold |
| None |
| RPM-FR-334 |
| None |
| The RPM shall not be affected by radiofrequency (RF) fields over the frequency range of 80 MHz to 2500 MHz at an intensity of 17.3 volts per meter (V/m), per modified ANSI N42.38, Section 8.3. |
| Requirement met = yes |
| Same as Threshold |
| Each side of the RPM with an opening shall be tested under RF fields of 17.3 V/m using a frequency sweep of 30 seconds at each level per the modified ANSI N42.38 Section 8.3 test direction. |
| RPM-FR-335 |
| None |
| The RPM RF emission limits when measured at 3 m shall be less than what is required by the 47 CFR 15.109 shown in the threshold table, per modified ANSI N42.38, Section 8.4. |
| Table from ANSI N42.38, Section 8.4 |
| Same as Threshold |
| None |
| RPM-FR-336 |
| None |
| The RPM shall operate on 120 V 60 Hz power +/- 12% nominal voltage and +/- 3% frequency. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-158-1 |
| None |
| The RPM shall operate for up to 3 hours after a loss of mainline power, excluding when the energy isolation device, or circuit breaker, is set to the OFF position. |
| Requirement met = yes |
| Same as Threshold |
| Must support the following LRUs, as a minimum: |
1) Gamma sensors;
2) Neutron sensors;
3) Signal processing unit;
4) Occupancy sensors;
5) File storage;
6) Basic control console.
| RPM-FR-158-2 |
| None |
| The RPM shall continue to record in non-volatile memory occupancy records, event records, and audit records for 3 hours after the loss of mainline power, excluding when the energy isolation device, or internal circuit breaker, is set to the Off position. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-338 |
| None |
| The RPM shall not be affected by exposure to electrostatic discharges of up to 6 kV using the contact discharge technique, per ANSI N42.38, Section 8.2. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-339 |
| None |
| The RPM shall not be affected by RF fields that can be conducted onto the portal through an external conducting cable, per ANSI N42.38, Section 8.6. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-340 |
| None |
| The RPM shall not be affected by surges or oscillatory waves of up to 2 kV that are classified as ring waves or combination waves with rise/decay times of 1.2/50 µs and 8/20 µs per ANSI N42.38, Section 8.7. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-341 |
| None |
| The RPM shall be unaffected by microphonic conditions such as those that may occur from low intensity sharp contacts at energies of up to 1.0 J, per ANSI N42.38, Section 9.2. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-342-1 |
| None |
| The RPM shall function normally when exposed to vibrations associated with equipment installed in non-weather protected location of up to 0.5 gn over a frequency range from 10 Hz to 150 Hz, per ANSI N42.38, Section 9.1. |
| The physical condition of the RPM shall not be affected by exposure to vibrations (e.g., solder joints shall hold; nuts and bolts shall not come loose). |
| Same as Threshold |
| None |
| RPM-FR-289 |
| None |
| External, non-conduit connections to the RPM shall be using commercial fittings rated water resistant to IP57 per IEC 60529-2004. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-27 |
| None |
| The system components exposed to the outdoors shall be configurable to withstand and remain physically intact and electro-mechanically undamaged from temporary flooding or hurricane wind driven water exposure only at locations subject to such conditions. |
| Protection from water incursion/ corrosion due to flooding to a height of 40 inches above ground for 24 hours, and minor-level hurricane wind-driven water spray up to 110 miles per hour for same hours. |
| Same as Threshold, except Category 3 hurricane wind-driven water spray up to 129 miles per hour. |
| None |
| RPM-FR-414 |
| None |
| A Zone A qualified RPM enclosure shall be immersible in water up to 4 feet deep for up to 24 hours. |
| The RPM configuration shall be considered to have met this requirement if at the conclusion of a test equivalent to immersing the enclosure into water 4 ft. (1.2 m) deep for 24 hours, no water has entered the enclosure. |
| Same as Threshold |
| Zone A configuration is for deployment in all locations within the Federal Emergency Management Agency defined 100 year flood plain. |
| RPM-FR-413 |
| None |
| External, non-conduit connections to the Zone A configuration RPM shall use commercial fittings rated waterproof to IP68 per IEC 60529-2004. |
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-FR-417 |
| None |
| A Zone A qualified RPM enclosure shall not have external crevices or cracks that allow build-up of materials that prevent system operation. |
Note: Special attention to optical sensors.
| Requirement met = yes |
| Same as Threshold |
| None |
| RPM-OR-28 |
| None |
| The system components exposed to the outdoors shall be configurable to withstand and remain physically intact and electro-mechanically undamaged from hurricane force winds only at locations subject to such conditions. |
| No physical or electro-mechanical damage after continuous exposure to minor level hurricane horizontal wind load up to 110 miles per hour for 24 hours. |
| Same as Threshold, except Category 3 hurricane force winds load up to 129 miles per hour. |
| None |
| RPM-FR-415 |
| None |
| The RPM in a normal configuration or Zone A configuration shall be able to withstand forces from wind loading generated by (Threshold: 110 mph; Objective: 129 mph) winds on the external surfaces of the RPM enclosures. |
| 110 mph |
| 129 mph |
| None |
| RPM-OR-29 |
| None |
| The system components exposed to the outdoors shall be configurable to withstand and remain physically intact and electro-mechanically undamaged from seasonal road salt spray and snow drifts at select northern U.S. locations. |
| Protection from water incursion/ corrosion due to snow drifts to a height of 192 inches above ground for 24 hours, and repeated road salt water splashes at a rate of 120 splashes per hour for 168 hours. |
| Threshold, plus protection from salt fog. |
| None |
| RPM-FR-416 |
| None |
| The RPM Zone A qualified configuration shall not corrode under long-term high salt conditions Military Standard (MIL-STD-810G (2014) 509.6). |
| Requirement met = yes |
| Same as Threshold |
| To qualify for Zone A application, an RPM configuration is tested for no corrosion or degradation under a 48 hour salt-fog test (MIL-STD-810G (2014), Section 509.6) tested at 5.0% NaCl and neutral pH (6.5 to 7.2) |
| RPM-OR-30 |
| None |
| The system shall operate without degradation while experiencing heat loading above and beyond ambient temperature due to direct sunlight, at select southern U.S. locations. |
| Operate without degradation with solar heat loading at no less than 110 Watts/square foot. (Average solar gain for desert areas where system is in operational use at CBP-specified southern U.S. locations.) Note: See Part II, Method 505.6 of MIL-STD-810G (2014). |
| Same as Threshold. |
| None |
| RPM-FR-418 |
| None |
| The standard configuration RPM shall be functional after being exposed to solar radiation for 24 hours with an hourly maximum of 110 W/ft2 between ambient temperatures of 42 °C to 43 °C following MIL-STD-810G (2014), method 505.6 Procedure I, category A2. |
| The RPM is operational after exposure to solar radiation of 110 W/ft2 using modified MIL-STD-810G (2014), Method 505.6, Procedure I, category A2. |
| Same as Threshold |
| None |
| RPM-FR-419 |
| None |
| A warm climate qualified RPM shall be functional after being exposed to solar radiation for 24 hours with an hour maximum of 110 W/ft2 between ambient temperatures of 44 °C to 47 °C following MIL-STD-810G (2014), method 505.6 Procedure I, category A1. |
| The RPM is operational after exposure to solar radiation of 110 W/ft2 using modified MIL-STD-810G (2014), Method 505.6, Procedure I, category A1. |
| Same as Threshold |
| This requirement is for qualification of RPMs for warm climate zone deployments. |
| RPM-OR-31 |
| None |
| The system shall have a long life cycle while maintaining performance. |