DIV 06 Wood.pdf

PDF 125 KB Posted

Attached to
SERE Parking Lot Expansion
Solicitation number
N4008525R9012
Issued by

About this file

This file is a division 06 technical specification for wood-related construction materials and fabrication for the P-1574 MRSB Operation Support Facility at MCB Camp Lejeune, NC. The document covers multiple wood-related sections including:

Rough Carpentry (Section 06 10 00): Provides detailed requirements for lumber grading, moisture content, preservative and fire-retardant treatments, wood species, lumber sizes, marking, and installation standards. Specifies requirements for framing lumber, structural lumber, plywood, and other wood materials with strict guidelines on material quality, moisture content, and treatment processes. Includes provisions for wood preservation, fire-retardant treatments, and specific installation techniques for various wood components.

Plastic-Laminate-Clad Architectural Cabinets (Section 06 41 16.00 10): Details specifications for custom casework cabinets, including material requirements, fabrication methods, hardware, adhesives, and installation standards. Covers cabinet construction using high-pressure laminate, plywood, and hardwood materials, with precise requirements for component thicknesses, joinery methods, edge finishing, and surface treatments. Includes specific requirements for drawer assemblies, shelving, and finishing techniques to meet premium grade quality standards.

Solid Surfacing Fabrications (Section 06 61 16): Provides technical specifications for solid polymer surface materials used in countertops, wall panels, window stools, and other architectural elements. Specifies material performance requirements, including physical properties, emissions standards, and fabrication techniques. Covers installation methods for various solid surface components, including joining techniques, edge finishing, and sealing requirements, with emphasis on achieving a monolithic appearance and meeting indoor air quality standards.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

P-1574 MRSB OPERATION SUPPORT FACILITY (OSF) 1717488

MCB CAMP LEJEUNE, NC

SECTION 06 10 00

ROUGH CARPENTRY

08/ 16, CHG 2: 11/ 18

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN INSTITUTE OF TIMBER CONSTRUCTION (AITC)

AITC TCM (2012) Timber Construction Manual, 5th Edition

AMERICAN LUMBER STANDARDS COMMITTEE (ALSC)

ALSC PS 20 (2015) American Softwood Lumber Standard

AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME)

ASME B18.2.1 (2012; Errata 2013) Square and Hex Bolts and Screws (Inch Series)

ASME B18.2.2 (2022) Nuts for General Applications:

Machine Screw Nuts, and Hex, Square, Hex Flange, and Coupling Nuts (Inch Series)

ASME B18.5.2.1M (2006; R 2011) Metric Round Head Short Square Neck Bolts

ASME B18.5.2.2M (1982; R 2010) Metric Round Head Square Neck Bolts

ASME B18.6.1 (2016) Wood Screws (Inch Series)

AMERICAN WOOD COUNCIL (AWC)

AWC NDS (2015) National Design Specification (NDS) for Wood Construction

AWC WFCM (2012) Wood Frame Construction Manual for One- and Two-Family Dwellings

AMERICAN WOOD PROTECTION ASSOCIATION (AWPA)

AWPA BOOK (2015) AWPA Book of Standards

AWPA M2 (2019) Standard for the Inspection of Preservative Treated Wood Products for Industrial Use

AWPA M6 (2013) Brands Used on Preservative Treated Materials

SECTION 06 10 00 Page 1

AWPA P5 (2015) Standard for Waterborne Preservatives

AWPA U1 (2022) Use Category System: User Specification for Treated Wood

APA - THE ENGINEERED WOOD ASSOCIATION (APA)

APA EWS T300 (2007) Technical Note: Glulam Connection Details

APA F405 (19) Product Guide: Performance Rated Panels

APA L870 (2010) Voluntary Product Standard, PS 1-09, Structural Plywood

ASTM INTERNATIONAL (ASTM)

ASTM A153/A153M (2016a) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware

ASTM A307 (2021) Standard Specification for Carbon Steel Bolts, Studs, and Threaded Rod 60 000 PSI Tensile Strength

ASTM D2898 (2010; R 2017) Standard Practice for Accelerated Weathering of Fire-Retardant-Treated Wood for Fire Testing

ASTM F547 (2017) Standard Terminology of Nails for Use with Wood and Wood-Base Materials

ASTM F1667/F1667M (2021a) Standard Specification for Driven Fasteners: Nails, Spikes, and Staples

FM GLOBAL (FM)

FM 4435 (2013) Roof Perimeter Flashing

INTERNATIONAL CODE COUNCIL (ICC)

ICC IBC (2021) International Building Code

SOUTHERN PINE INSPECTION BUREAU (SPIB)

SPIB 1003 (2014) Standard Grading Rules for Southern Pine Lumber

TRUSS PLATE INSTITUTE (TPI)

TPI 1 (2014) National Design Standard for Metal Plate Connected Wood Truss Construction, Including Commentary and Appendices

SECTION 06 10 00 Page 2

U.S. GENERAL SERVICES ADMINISTRATION (GSA)

CID A-A-1923 (Rev A; Notice 3) Shield, Expansion (Lag, Machine and Externally Threaded Wedge Bolt Anchors)

CID A-A-1924 (Rev A; Notice 3) Shield, Expansion (Self Drilling Tubular Expansion Shell Bolt Anchors

CID A-A-1925 (Rev A; Notice 3) Shield Expansion (Nail Anchors)

1.2 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-03 Product Data

Fire-retardant Treatment

Rough Hardware

SD-06 Test Reports

Preservative-treated Lumber and Plywood

SD-07 Certificates

Certificates of Grade

Preservative Treatment

1.3 DELIVERY AND STORAGE

Deliver materials to the site in an undamaged condition. Store, protect, handle, and install prefabricated structural elements in accordance with manufacturer's instructions and as specified. Store materials off the ground to provide proper ventilation, with drainage to avoid standing water, and protection against ground moisture and dampness. Store materials with a moisture barrier at both the ground level and as a cover forming a well ventilated enclosure. Store wood I-beams and glue-laminated beams and joists on edge. Adhere to requirements for stacking, lifting, bracing, cutting, notching, and special fastening requirements. Do not use materials that have visible moisture or biological growth. Remove defective and damaged materials and provide new materials. Store separated reusable wood waste convenient to cutting station and area of work.

1.4 GRADING AND MARKING

1.4.1 Lumber

Mark each piece of framing and board lumber or each bundle of small pieces of lumber with the grade mark of a recognized association or independent inspection agency. Such association or agency must be certified by the

SECTION 06 10 00 Page 3

Board of Review, American Lumber Standards Committee, to grade the species used. Surfaces that are to be exposed to view must not bear grademarks, stamps, or any type of identifying mark. Hammer marking will be permitted on timbers when all surfaces will be exposed to view.

1.4.2 Plywood

Mark each sheet with the mark of a recognized association or independent inspection agency that maintains continuing control over the quality of the plywood. The mark must identify the plywood by species group or span rating, exposure durability classification, grade, and compliance with APA L870 . Surfaces that are to be exposed to view must not bear grademarks or other types of identifying marks.

1.4.3 Structural-Use and OSB Panels

Mark each panel with the mark of a recognized association or independent inspection agency that maintains continuing control over the quality of the panel. The mark must indicate end use, span rating, and exposure durability classification. Oriented Strand Board (OSB), APA F405 .

1.4.4 Preservative-Treated Lumber, Timber and Plywood

The Contractor is responsible for the quality of treated wood products.

Each treated piece must be inspected in accordance with AWPA M2 and permanently marked or branded, by the producer, in accordance with AWPA M6.

The Contractor must provide Contracting Officer's Representative (COR) with the inspection report of an approved independent inspection agency that offered products comply with applicable AWPA Standards. The appropriate Quality Mark on each piece will be accepted, in lieu of inspection reports, as evidence of compliance with applicable AWPA treatment standards.

1.4.5 Fire-Retardant Treated Lumber

Mark each piece in accordance with AWPA M6, except pieces that are to be natural or transparent finished. In addition, exterior fire-retardant lumber must be distinguished by a permanent penetrating blue stain.

Labels of a nationally recognized independent testing agency will be accepted as evidence of conformance to the fire-retardant requirements of

AWPA M6.

1.5 SIZES AND SURFACING

ALSC PS 20 for dressed sizes of yard and structural lumber. Lumber must be surfaced four sides. Size references, unless otherwise specified, are nominal sizes, and actual sizes must be within manufacturing tolerances allowed by the standard under which the product is produced. Other measurements are IP or SI standard.

1.6 MOISTURE CONTENT

Air-dry or kiln-dry lumber. Kiln-dry treated lumber after treatment.

Maximum moisture content of wood products must be as follows at the time of delivery to the job site:

a. Framing lumber and board, 19 percent maximum b. Timbers 5 inches and thicker, 15 percent maximum. Framing lumber 15 percent maximum for footbridge.

SECTION 06 10 00 Page 4

1.7 PRESERVATIVE TREATMENT

Treat wood products with waterborne wood preservatives conforming to AWPA P5. Pressure treatment of wood products must conform to the requirements of AWPA BOOK Use Category System Standards U1 and T1.

Pressure-treated wood products must not contain arsenic, chromium, or other agents classified as carcinogenic, probably carcinogenic, or possibly carcinogenic to humans (compounds in Groups 1, 2A, or 2B) by the International Agency for Research on Cancer (IARC), Lyon, France.

Pressure-treated wood products must not exceed the limits of the U.S.

EPA's Toxic Characteristic Leaching Procedure (TCLP), and must not be classified as hazardous waste. Submit certification from treating plant stating chemicals and process used and net amount of preservatives retained are in conformance with specified standards. In accordance with AWPA U1 provide non-copper preservative treatment such as EL2, PTI or SBX,DOT for products in direct contact with sheet metal.

a. 0.25 pcf intended for above ground use.

b. 0.40 pcf intended for ground contact and fresh water use. 0.60 pcf intended for Ammoniacal Copper Quaternary Compound (ACQ)-treated foundations. 0.80 to 1.00 pcf intended for ACQ-treated pilings. All wood must be air or kiln dried after treatment. Specific treatments must be verified by the report of an approved independent inspection agency, or the AWPA Quality Mark on each piece. Do not incise surfaces of lumber that will be exposed. Brush coat areas that are cut or drilled after treatment with either the same preservative used in the treatment or with a 2 percent copper naphthenate solution. All lumber and woodwork must be preservative treated. Plastic lumber must not be preservative treated. The following items must be preservative treated:

(1) Wood framing, woodwork, and plywood up to and including the subflooring at the first-floor level of structures having crawl spaces when the bottoms of such items are 24 inches or less from the earth underneath.

(2) Wood members that are in contact with water.

(3) Exterior wood steps, platforms, and railings; and all wood framing of open, roofed structures.

(4) Wood sills, soles, plates, furring, and sleepers that are less than 24 inches from the ground, furring and nailers that are set into or in contact with concrete or masonry.

(5) Nailers, edge strips, crickets, curbs, and cants for roof decks.

1.8 FIRE-RETARDANT TREATMENT

Fire-retardant treated wood must be pressure treated Treatment and performance inspection must be by an independent and qualified testing agency that establishes performance ratings. Each piece or bundle of treated material must bear identification of the testing agency to indicate performance in accordance with such rating. Treated materials to be exposed to rain wetting must be subjected to an accelerated weathering technique in accordance with ASTM D2898 prior to being tested. Such items

SECTION 06 10 00 Page 5 which will not be inside a building, and such items which will be exposed to heat or high humidity, must receive exterior fire-retardant treatment.

Fire-retardant-treated wood products must be free of halogens, sulfates, ammonium phosphate, and formaldehyde. Items to be treated include the following:

a. As indicated and as specified herein.

1.9 QUALITY ASSURANCE

1.9.1 Drawing Requirements

For fabricated structural members, trusses, qlu-lam members, indicate materials, details of construction, methods of fastening, and erection details. Include reference to design criteria used and manufacturers design calculations. Submit drawings for all proposed modifications of structural members. Do not proceed with modifications until the submittal has been approved.

1.9.2 Data Required

Submit calculations and drawings for all proposed modifications of structural members. Do not proceed with modifications until the submittal has been approved.

1.10 CERTIFICATIONS

1.10.1 Certified Wood Grades

Provide certificates of grade from the grading agency on graded but unmarked lumber or plywood attesting that materials meet the grade requirements specified herein. Provide certificates of grade for all wood material specified for the foot bridge.

PART 2 PRODUCTS

2.1 MATERIALS

2.2 LUMBER

2.2.1 Structural Lumber

Grade and species as indicated for footbridge.

2.2.2 Framing Lumber

Framing lumber such as studs, plates, caps, collar beams, cant strips, bucks, sleepers, nailing strips, and nailers and board lumber such as subflooring and wall and roof sheathing must be one of the species listed in the table below. Minimum grade of species must be as listed.

SECTION 06 10 00 Page 6

Table of Grades for Framing and Board Lumber

Grading Rules Species Framing Board Lumber

SECTION 06 10 00 Page 7

Table of Grades for Framing and Board Lumber

Grading Rules Species Framing Board Lumber

SPIB 1003 standard grading rules

Southern Pine All Species:

Standard Light Framing or No. 3 Structural Light Framing (Stud Grade for 2x4 nominal size, 10 feet and shorter)

No. 2 Boards

SECTION 06 10 00 Page 8

Table of Grades for Framing and Board Lumber

Grading Rules Species Framing Board Lumber

2.3 PLYWOOD, STRUCTURAL-USE, AND ORIENTED STRAND BOARD (OSB) PANELS

2.3.1 Other Uses

2.3.1.1 Plywood

Plywood for mounting of electrical panels and other non-structural applications as indicated. C-D Grade, Exposure 1.

2.4 OTHER MATERIALS

2.4.1 Miscellaneous Wood Members

2.4.1.1 Blocking

Blocking must be standard or number 2 grade.

2.5 ROUGH HARDWARE

Unless otherwise indicated or specified, rough hardware must be of the type and size necessary for the project requirements. Sizes, types, and spacing of fastenings of manufactured building materials must be as recommended by the product manufacturer unless otherwise indicated or specified. Rough hardware exposed to the weather or embedded in or in contact with preservative treated wood, exterior masonry, or concrete walls or slabs must be hot-dip zinc-coated in accordance with ASTM A153/A153M unless otherwise noted to stainless steel. Submit product data for rough hardware and indicate where each product will be used.

Provide details as needed to clearly indicated where product will be installed.

2.5.1 Bolts, Nuts, Studs, and Rivets

ASME B18.2.1 Typical and ASTM A325 for footbridge, ASME B18.5.2.1M , ASME B18.5.2.2M and ASME B18.2.2 .

2.5.2 Anchor Bolts

ASTM A307, size as indicated, complete with nuts and washers.

2.5.3 Expansion Shields

CID A-A-1923 , CID A-A-1924 , and CID A-A-1925 . Except as shown otherwise, SECTION 06 10 00 Page 9 maximum size of devices must be 3/8 inch.

2.5.4 Lag Screws and Lag Bolts

ASME B18.2.1 .

2.5.5 Wood Screws

ASME B18.6.1 .

2.5.6 Nails

ASTM F547, size and type best suited for purpose; staples must be as recommended by the manufacturer of the materials to be joined. For sheathing and subflooring, length of nails must be sufficient to extend 1 inch into supports. In general, 8-penny or larger nails must be used for nailing through 1 inch thick lumber and for toe nailing 2 inch thick lumber; 16-penny or larger nails must be used for nailing through 2 inch thick lumber. Nails used with treated lumber and sheathing must be hot-dipped galvanized in accordance with ASTM A153/A153M . Nailing must be in accordance with the recommended nailing schedule contained in AWC WFCM.

Where detailed nailing requirements are not specified, nail size and spacing must be sufficient to develop an adequate strength for the connection. The connection's strength must be verified against the nail capacity tables in AWC NDS. Reasonable judgment backed by experience must ensure that the designed connection will not cause the wood to split. If a load situation exceeds a reasonable limit for nails, a specialized connector must be used.

2.5.7 Wire Nails

ASTM F1667/F1667M .

2.5.8 Timber Connectors

Unless otherwise specified, timber connectors must be in accordance with TPI 1 , APA EWS T300 or AITC TCM.

2.5.9 Clip Angles and Plates

Steel, 3/16 inch thick, size as indicated best suited for intended use; or zinc-coated steel or iron commercial clips designed for connecting wood members.

PART 3 EXECUTION

3.1 INSTALLATION

Do not install building construction materials that show visual evidence of biological growth.

Fit framing lumber and other rough carpentry, set accurately to the required lines and levels, and secure in place in a rigid manner. Provide as necessary for the proper completion of the work all framing members not indicated or specified. Spiking and nailing not indicated or specified otherwise must be in accordance with the Nailing Schedule contained in ICC IBC ; perform bolting in an approved manner. Spikes, nails, and bolts must be drawn up tight.

SECTION 06 10 00 Page 10

3.1.1 Beams and Girders

Set beams and girders level and in alignment and anchor to piles or supports as indicated.

3.1.2 Joists

Provide joists of the sizes and spacing indicated, accurately and in alignment, and of uniform width. Joists must have full bearing on sills, plates, beams, and girders; provide laps over bearing only and connect as indicated.

3.1.2.1 Tie Straps

For joists supported by the lower flange of steel beams, provide straps at every fourth joist and the corresponding fourth joist on the opposite side. Tie joists across the top of the steel beam with a steel strap.

Form straps to lie flat across the top of the beam and twist at the ends.

3.2 MISCELLANEOUS

3.2.1 Wood Roof Nailers, Edge Strips, Crickets, Curbs, and Cants

3.2.1.1 Roof Edge Strips and Nailers

Provide at perimeter of roof, around openings through roof, and where roofs abut walls, curbs, and other vertical surfaces. Except where indicated otherwise, nailers must be 6 inches wide and the same thickness as the insulation. Anchor nailers securely to underlying construction.

Anchor perimeter nailers in accordance with FM 4435 .

3.2.2 Wood Blocking

Provide proper sizes and shapes at proper locations for the installation and attachment of wood and other finish materials, fixtures, equipment, and items indicated or specified.

3.2.3 Temporary Closures

Provide with hinged doors and padlocks and install during construction at exterior doorways and other ground level openings that are not otherwise closed. Cover windows and other unprotected openings with polyethylene or other approved material, stretched on wood frames. Provide dustproof barrier partitions to isolate areas as directed.

3.3 SPECIAL INSPECTION

Special inspections for footbridge components must be done in accordance with Section 01 45 35 SPECIAL INSPECTIONS.

3.4 WASTE MANAGEMENT OF WOOD PRODUCTS

In accordance with the Waste Management Plan and as specified.

-- End of Section --

SECTION 06 10 00 Page 11

SECTION 06 41 16.00 10

PLASTIC-LAMINATE-CLAD ARCHITECTURAL CABINETS

08/ 10, CHG 1: 11/ 18

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI)

ANSI A161.2 (1998) Decorative Laminate Countertops, Performance Standards for Fabricated High Pressure

ASTM INTERNATIONAL (ASTM)

ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials

BUILDERS HARDWARE MANUFACTURERS ASSOCIATION (BHMA)

ANSI/BHMA A156.9 (2020) Cabinet Hardware

COMPOSITE PANEL ASSOCIATION (CPA)

CPA A208.2 (2016) Medium Density Fiberboard (MDF) for Interior Applications

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

WINDOW AND DOOR MANUFACTURERS ASSOCIATION (WDMA)

ANSI/WDMA I.S.1A (2013) Interior Architectural Wood Flush Doors

WOODWORK INSTITUTE (WI)

NAAWS 3.1 (2017; 2018 Errata Edition) North American Architectural Woodwork Standards

1.2 SYSTEM DESCRIPTION

Work in this section includes laminate clad custom casework cabinets vanities as shown on the drawings and as described in this specification.

This Section includes high-pressure laminate surfacing and cabinet hardware. Comply with EPA requirements in accordance with Section 01 33 29 SUSTAINABILITY REQUIREMENTS AND REPORTING. Sand smooth and apply a clear finish of polyurethane to all exposed and semi-exposed surfaces, whose finish is not otherwise noted on the drawings or finish schedule. Wood

SECTION 06 41 16.00 10 Page 1 finish may be shop finished or field applied in accordance with Section

09 90 00 PAINTS AND COATINGS.

1.3 SUSTAINABILITY REPORTING

Materials in this technical specification may contribute towards contract compliance with sustainability requirements. See Section 01 33 29 SUSTAINABILITY REPORTING low-emitting materials, LEED documentation requirements.

1.4 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Shop Drawings

Installation

SD-03 Product Data

Finish Schedule

SD-04 Samples

Plastic Laminates

Cabinet Hardware

SD-07 Certificates

Quality Assurance

Laminate Clad Casework

SD-11 Closeout Submittals

LEED Documentation

1.5 QUALITY ASSURANCE

1.5.1 General Requirements

Unless otherwise noted on the drawings, furnish all materials, construction methods, and fabrication conforming to and complying with the premium grade quality standards as outlined in NAAWS 3.1, Section for laminate clad cabinets. These standards apply in lieu of omissions or specific requirements in this specification. Contractors and their personnel engaged in the work must be able to demonstrate successful experience with work of comparable extent, complexity and quality to that shown and specified. Submit a quality control statement which illustrates compliance with and understanding of NAAWS 3.1 requirements, in general, and the specific NAAWS 3.1 requirements provided in this specification.

The quality control statement must also certify a minimum of ten years Contractor's experience in laminate clad casework fabrication and

SECTION 06 41 16.00 10 Page 2 construction. Provide a list of a minimum of five successfully completed projects of a similar scope, size, and complexity in the quality control statement.

1.5.2 Mock-ups

Prior to final approval of shop drawings, provide a full-size mock-up of a typical floor cabinet wall cabinet, including all components and hardware necessary to illustrate a completed unit with a minimum of one door and one drawer assembly. Include countertops and back splashes where specified. Utilize specified finishes in the patterns and colors as indicated. Upon disapproval, rework or remake the mock-up until approval is secured. Remove rejected units from the jobsite. Approved mock-up may remain as part of the finished work. Submit shop drawings showing all fabricated casework items in plan view, elevations and cross-sections to accurately indicate materials used, details of construction, dimensions, methods of fastening and erection, and installation methods proposed.

Clearly cross-reference shop drawing casework items to casework items located on the project drawings. Shop drawings will include a color schedule of all casework items to include all countertop, exposed, and semi-exposed cabinet finishes to include finish material manufacturer, pattern, and color.

1.6 DELIVERY, STORAGE, AND HANDLING

Casework may be delivered knockdown or fully assembled. Deliver all units to the site in undamaged condition, stored off the ground in fully enclosed areas, and protected from damage. Ventilate the storage area and do not subject to extreme changes in temperature or humidity.

1.7 SEQUENCING AND SCHEDULING

Coordinate work with other trades. Do not install units in any room or space until painting, and ceiling installation are complete within the room where the units are located. Install floor cabinets before finished flooring materials are installed.

PART 2 PRODUCTS

2.1 WOOD MATERIALS

2.1.1 Lumber

a. Provide kiln-dried Grade III framing lumber to dimensions as shown on the drawings. Frame front, where indicated on the drawings, must be nominal 3/4 inch hardwood.

b. Standing or running trim casework components, which are specified to receive a transparent finish, must be hardwood species, plain sawn.

AWI grade must be premium. Indicate location, shape, and dimensions on the drawings.

2.1.2 Panel Products

2.1.2.1 Plywood

Use veneer core hardwood plywood, NAAWS 3.1 Grade AA panels for framing purposes. Indicate nominal thickness of plywood panels in this specification and on the drawings.

SECTION 06 41 16.00 10 Page 3

2.1.2.2 Medium Density Fiberboard

Use moisture resistant medium density fiberboard (MDF) for base board of cabinets. Finish MDF with shop fabricated paint sealer appropriate for moisture resistance. Medium density fiberboard will meet the minimum standards listed in CPA A208.2 .

2.2 SOLID POLYMER MATERIAL

Provide solid surfacing casework components in conformance to the requirements of Section 06 61 16 SOLID SURFACING FABRICATIONS.

2.3 HIGH PRESSURE LAMINATE (HPL-1)

Provide plastic laminates meeting the requirements of ANSI/NEMA LD 3 and ANSI A161.2 for high-pressure decorative laminates. Indicate design, colors, surface finish and texture, and locations on the drawings. Submit two samples of each plastic laminate pattern and color. Samples less than 5 by 7 inches in size are not acceptable. Provide plastic laminate types and nominal minimum thicknesses for casework components as indicated in the following paragraphs.

2.3.1 Horizontal General Purpose Standard (HGS) Grade

Provide horizontal general purpose standard grade plastic laminate that is

0.048 inches (plus or minus 0.005 inches) in thickness. This laminate grade is intended for horizontal surfaces where postforming is not required.Laminate grade shall have a Class 1, fire rating in accordance with ASTM E84.

2.3.2 Vertical General Purpose Standard (VGS) Grade

Provide vertical general purpose standard grade plastic laminate that is

0.028 inches (plus or minus 0.004 inches) in thickness. This laminate grade is intended for exposed exterior vertical surfaces of casework components where postforming is not required.

2.3.3 Cabinet Liner Standard (CLS) Grade

Provide cabinet liner standard grade plastic laminate that is 0.020 inches in thickness. This laminate grade is intended for light duty semi-exposed interior surfaces of casework components.

2.3.4 Backing Sheet (BK) Grade

Undecorated backing sheet grade laminate is formulated specifically to be used on the backside of plastic laminated panel substrates to enhance dimensional stability of the substrate. Backing sheet thickness must be

0.020 inches. Provide backing sheets for all laminated casework components where plastic laminate finish is applied to only one surface of the component substrate.

2.4 EDGE BANDING

Provide PVC vinyl, 0.125 inch thick, edge banding for casework doors and drawer fronts. Material width must match thickness of cabinet door.

Color and pattern must match exposed door and drawer front laminate pattern and color.

SECTION 06 41 16.00 10 Page 4

2.5 CABINET HARDWARE

Submit one sample of each cabinet hardware item specified to include self closing hinges, pulls, drawer glides Provide hardware conforming to ANSI/BHMA A156.9 , unless otherwise noted, and consisting of the following components:

2.5.1 Door Hinges

Provide frameless concealed European style, back mounted hinges with 165 degree opening and a self-closingfeature when at less than 90 degrees open.

2.5.2 Cabinet Pulls

Provide drawer pulls as wire type pulls with center-to-center dimension of not less than 3 1/2 inches and a cross sectional diameter of 5/16 inch.

Provide handle projections not less than 1 5\16 inches. Provide handle, pull options for designer approval before product order.

2.5.3 Drawer Slide

Provide drawer slides having a static rating capacity of 100 pounds.

Slides to have a self closing/stay closed action, zinc or epoxy coated steel finish, ball bearing rollers, and positive stop with lift out design.

2.5.4 Adjustable Shelf Support System

Recessed (mortised) metal standards, BHMA No. BO4071, finish: brass.

Support clips for the standards must be open type, BHMA No. B04091, finish: brass Multiple holes with metal pin supports.

2.6 ADHESIVES, CAULKS, AND SEALANTS

2.6.1 Adhesives

Use formula and type of adhesives recommended by AWI. Select adhesives for their ability to provide a durable, permanent bond and take into consideration such factors as materials to be bonded, expansion and contraction, bond strength, fire rating, and moisture resistance. Meet local regulations regarding VOC emissions and off-gassing.

2.6.1.1 Wood Joinery

Use Type II for interior use urea-formaldehyde resin formula adhesives to bond wood members. Adhesives must withstand a bond test as described in

ANSI/WDMA I.S.1A .

2.6.1.2 Laminate Adhesive

Adhesive used to join high-pressure decorative laminate to wood must be a water-based contact adhesive consistent with AWI and laminate manufacturer's recommendations. Adhere PVC edgebanding using a polymer-based hot melt glue.

2.6.2 Caulk

Use clear, 100 percent silicone caulk to fill voids and joints between laminated components and between laminated components and adjacent

SECTION 06 41 16.00 10 Page 5 surfaces.

2.6.3 Sealant

Use sealant recommended by the substrate manufacturer to provide a moisture barrier at sink cutouts and all other locations where unfinished substrate edges may be subjected to moisture.

2.7 ACCESSORIES

2.7.1 Grommets

Use material for cutouts with a diameter of 2 1/2 inches. Indicate locations on the drawings.

2.8 FABRICATION

Verify field measurements as indicated in the shop drawings before fabrication. Accomplish fabrication and assembly of components at the shop site to the maximum extent possible. Meet or exceed the requirements for AWI premium grade unless otherwise indicated in this specification.

Make cabinet style, in accordance with NAAWS 3.1, Section 400-G descriptions, flush overlay as indicated on the drawings.

2.8.1 Base and Wall Cabinet Case Body

2.8.1.1 Cabinet Components

Use frame members that are glued-together, kiln-dried hardwood lumber.

Brace top corners, bottom corners, and cabinet bottoms with either hardwood blocks or water-resistant glue and nailed in place metal or plastic corner braces. Construct cabinet components from the following materials and thicknesses:

2.8.1.1.1 Body Members (Ends, Divisions, Bottoms, and Tops)

3/4 inch veneer core plywood panel product

2.8.1.1.2 Face Frames and Rails

3/4 inch hardwood lumber panel product

2.8.1.1.3 Shelving

3/4 inch veneer core plywood panel product

2.8.1.1.4 Cabinet Backs

1/4 inch veneer core plywood panel product

2.8.1.1.5 Drawer Sides, Backs, and Subfronts

1/2 inch hardwood lumber panel product

2.8.1.1.6 Drawer Bottoms

1/4 inch veneer core plywood panel product

SECTION 06 41 16.00 10 Page 6

2.8.1.1.7 Door and Drawer Fronts

3/4-inch multi-ply core plywood panel product

2.8.1.2 Joinery Method for Case Body Members

2.8.1.2.1 Tops, Exposed Ends, and Bottoms

a. Steel "European" assembly screws ( 1-1/2 inch from end, 5 inch on center, fasteners will not be visible on exposed parts).

b. Doweled, glued under pressure (approx. 4 dowels per 12 inches of joint).

c. Stop dado, glued under pressure, and either nailed, stapled or screwed (fasteners will not be visible on exposed parts).

d. Spline or biscuit, glued under pressure.

2.8.1.2.2 Exposed End Corner and Face Frame Attachment

2.8.1.2.2.1 Mitered Joint

lock miter or spline or biscuit, glued under pressure (no visible fasteners)

2.8.1.2.2.2 Non-Mitered Joint (90 degree)

butt joint glued under pressure (no visible fasteners)

2.8.1.2.2.3 Butt Joint

glued and nailed

2.8.1.2.3 Cabinet Backs (Wall Hung Cabinets)

Wall hung cabinet backs must not be relied upon to support the full weight of the cabinet and its anticipated load for hanging/mounting purposes.

Method of back joinery and hanging/mounting mechanisms should transfer the load to case body members. Use the following fabrication method:

2.8.1.2.3.1 Full Bound

Full bound, captured in grooves on cabinet sides, top, and bottom.

Cabinet backs for floor standing cabinets must be side bound, captured in grooves; glued and fastened to top and bottom.

2.8.1.2.3.2 Full Overlay

Full overlay, plant-on backs with minimum back thickness of 1/2 inchand minimum No. 12 plated (no case hardened) screws spaced a minimum 3 inches on center. Do not expose edge of back on finished sides. Anchor strips are not required when so attached.

2.8.1.2.3.3 Side Bound

Side bound, captured in groove or rabbetts; glued and fastened.

SECTION 06 41 16.00 10 Page 7

2.8.1.2.4 Cabinet Backs (Floor Standing Cabinets)

2.8.1.2.4.1 Side Bound

Side bound, captured in grooves; glued and fastened to top and bottom.

2.8.1.2.4.2 Full Overlay

Full overlay, plant-on backs with minimum back thickness of 1/2 inch and minimum No. 12 plated (no case hardened) screws spaced a minimum 3 inches on center. Do not expose edge of back on finished sides. Anchor strips are not required when so attached.

2.8.1.2.4.3 Side Bound with Rabbetts

Side bound, placed in rabbetts; glued and fastened in rabbetts.

2.8.1.2.5 Wall Anchor Strips

Wall Anchor Strips are required for all cabinets with backs less than 1/2 inch thick. Use strips consisting of minimum 1/2 inch thick lumber, minimum 2-1/2 inches width; securely attache to wall side of cabinet back

- top and bottom for wall hung cabinets, top only for floor standing cabinets.

2.8.2 Cabinet Floor Base

Mount floor cabinets on a base constructed of multi-ply veneer core exterior plywood. Provide base assembly components that are a moisture-resistant panel product. Make finished height for each cabinet base no less than the full height of the installed, specified wall base.

Make bottom edge of the cabinet door or drawer face extend below the top of the base as indicated on the drawings.

2.8.3 Cabinet Door and Drawer Fronts

Fabricate door and drawer fronts from 3/4 inch multi-ply core plywood.

Surface all door and drawer front edges with PVC edgebanding, color and pattern to match exterior face laminate.

2.8.4 Drawer Assembly

2.8.4.1 Drawer Components

Provide drawer components consisting of a removable drawer front, sides, backs, and bottom. Construct drawer components of the following materials and thicknesses:

2.8.4.1.1 Drawer Sides and Backs For Transparent Finish

1/2 inch thick 7-ply hardwood veneer core plywood (no voids), birchwood species.

2.8.4.1.2 Drawer Sides and Backs For Laminate Finish

1/2 inch thick 7-ply hardwood veneer core substrate.

SECTION 06 41 16.00 10 Page 8

2.8.4.1.3 Drawer Bottom

1/4 inch thick veneer core panel product for transparent or plastic laminate finish.

2.8.4.2 Drawer Assembly Joinery Method

a. Multiple dovetail (all corners) or French dovetail front/dadoed back, glued under pressure.

b. Doweled, glued under pressure.

c. Lock shoulder, glued and pin nailed.

d. Set bottoms into sides, front, and back, 1/4 inch deep groove with a minimum 3/8 inch standing shoulder.

2.8.5 Shelving

2.8.5.1 General Requirements

Fabricate shelving from 3/4 inch veneer core plywood. Finish all shelving top and bottom surfaces with HPDL plastic laminate. Finish shelf edges in a HPDL plastic laminate.

2.8.5.2 Shelf Support System

The shelf support system is as follows:

2.8.5.2.1 Pin Hole Method

Drill holes on the interior surface of the cabinet side walls. Evenly space holes in two vertical columns Space the holes in each column at 1 inch increments starting 6 inches from the cabinet interior bottom and extending to within 6 inches of the top interior surface of the cabinet.

Drill holes to provide a level, stable surface when the shelf is resting on the shelf pins. Coordinate hole diameter with pin insert size to provide a firm, tight fit.

2.8.6 Laminate Application

Apply laminate to substrates following the recommended procedures and instructions of the laminate manufacturer and ANSI/NEMA LD 3 , using tools and devices specifically designed for laminate fabrication and application. Provide a balanced backer sheet (Grade BK) wherever only one surface of the component substrate requires a plastic laminate finish.

Apply required grade of laminate in full uninterrupted sheets consistent with manufactured sizes using one piece for full length only, using adhesives specified herein or as recommended by the manufacturer. Fit corners and joints hairline. Machined flush, file, sand, or buff all laminate edges to remove machine marks and ease (sharp corners removed).

Clean up at easing must be such that no overlap of the member eased is visible. Perform fabrication in conformance to ANSI A161.2 . Provide laminate types and grades for component surfaces as follows unless otherwise indicated on the drawings:

2.8.6.1 High Pressure Decorative Laminate Casework

Provide casework of multi-ply core plywood covered with laminated plastic

SECTION 06 41 16.00 10 Page 9 sheets. Color of finish in accordance with drawings as indicated.

Casework Number Description

32BC-2 Cabinet, undercounter base unit with one adjustable shelf, two door. Provide left and right hand door. 34 inches high (overall with countertop) by 32 inches wide by 23 inches deep.

36BC-2 Cabinet, undercounter base unit with one adjustable shelf, two door. Provide left and right hand door. 34 inches high (overall with countertop) by 36 inches wide by 23 inches deep.

36SC Sink Base Cabinet with two doors, fixed drawer for sink, 36 inches wide by 34 inches high (overall with countertop) by 23 inches deep.

2230W Wall hung cabinet with two doors, 22 inches wide by 30 inches high by 15 inches deep.

3036MICRO Wall hung cabinet with microwave shelf, two doors, 30 inches wide by 36 inches high by 15 inches deep wall cabinet, 20 inch deep microwave shelf.

3624W Wall hung cabinet with two doors, 36 inches wide by 24 inches high by 15 inches deep.

3630W Wall hung cabinet with two doors, 36 inches wide by 30 inches high by 15 inches deep.

2.8.6.2 Base/Wall Cabinet Case Body

a. Exterior (exposed) surfaces to include exposed and semi-exposed face frame surfaces: HPDL Grade VGS.

b. Interior (semi-exposed) surfaces to include interior back wall, bottom, and side walls: HPDL Grade CLS.

2.8.6.3 Adjustable Shelving

2.8.6.3.1 Top and Bottom Surfaces

HPDL Grade HGS.

2.8.6.3.2 All Edges

HPDL Grade VGS.

2.8.6.4 Fixed Shelving

2.8.6.4.1 Top and Bottom Surfaces

HPDL Grade HGS.

2.8.6.4.2 Exposed Edges

HPDL Grade VGS.

SECTION 06 41 16.00 10 Page 10

2.8.6.5 Door, Drawer Fronts, Access Panels

2.8.6.5.1 Exterior (Exposed) and Interior (Semi-Exposed) Faces

HPDL Grade VGS.

2.8.6.5.2 Edges

PVC edgebanding.

2.8.6.6 Drawer Assembly

All interior and exterior surfaces: HPDL Grade CLS.

2.8.6.7 Tolerances

Meet the NAAWS 3.1 premium grade requirements for flushness, flatness, and joint tolerances of laminated surfaces.

2.8.7 Finishing

2.8.7.1 Filling

Do not expose fasteners on laminated surfaces. Make all nails, screws, and other fasteners in non-laminated cabinet components countersunk and fill the holes with wood filler consistent in color with the wood species.

2.8.7.2 Sanding

Prepare all surfaces requiring coatings by sanding with a grit and in a manner that scratches will not show in the final system.

2.8.7.3 Coatings

Types, method of application and location of casework finishes must be in accordance with the finish schedule, drawings and Section 09 90 00 PAINTS AND COATINGS. Paint all cabinet reveals. Submit descriptive data which provides narrative written verification of all types of construction materials and finishes, methods of construction, etc. not clearly illustrated on the submitted shop drawings. Provide written verification of conformance with NAAWS 3.1 for the quality indicated to include materials, tolerances, and types of construction. Both the manufacturer of materials and the fabricator must submit available literature which describes re-cycled product content, operations and processes in place that support efficient use of natural resources, energy efficiency, emissions of ozone depleting chemicals, management of water and operational waste, indoor environmental quality, and other production techniques supporting sustainable design and products.

PART 3 EXECUTION

3.1 INSTALLATION

Installation must comply with applicable requirements for NAAWS 3.1 premium quality standards. Install countertops and fabricated assemblies level, plumb, and true to line, in locations shown on the drawings. Attach and securely anchor cabinets and other laminate clad casework assemblies to the floor and walls with mechanical fasteners that are appropriate for the wall and floor construction.

SECTION 06 41 16.00 10 Page 11

3.1.1 Anchoring Systems

3.1.1.1 Floor

Utilize a floor anchoring system. Anchoring and mechanical fasteners must not be visible from the finished side of the casework assembly. Attach cabinet assemblies to anchored bases without visible fasteners. Where assembly abuts a wall surface, include a minimum 1/2 inch thick lumber or panel product hanging strip, minimum 2-1/2 inch width; securely attached to the top of the wall side of the cabinet back.

3.1.1.2 Wall

Utilize minimum 1/2 inch thick lumber or panel product hanging strips, minimum 2-1/2 inch width to wall mount cabinet vanity; securely attach to the wall side of the cabinet back, both top and bottom.

3.1.2 Hardware

Install casework hardware in types and locations as indicated on the drawings. Where fully concealed European-style hinges are specified to be used with particleboard or fiberboard doors, use plastic or synthetic insertion dowels to receive 3/16 inch "Euroscrews". The use of wood screws without insertion dowels is prohibited.

3.1.3 Doors, Drawers and Removable Panels

Accomplish the fitting of doors, drawers and removable panels within target fitting tolerances for gaps and flushness in accordance with NAAWS 3.1 premium grade requirements.

3.1.4 Plumbing Fixtures

Install sinks, sink hardware, and other plumbing fixtures in locations as indicated on the drawings and in accordance with Section 22 00 00

PLUMBING, GENERAL PURPOSE.

SECTION 06 41 16.00 10 Page 12

SECTION 06 61 16

SOLID SURFACING FABRICATIONS

08/20

PART 1 GENERAL

1.1 REFERENCES

The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.

ASTM INTERNATIONAL (ASTM)

ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants

ASTM D570 (1998; E 2010; R 2010) Standard Test Method for Water Absorption of Plastics

ASTM D638 (2014) Standard Test Method for Tensile Properties of Plastics

ASTM D696 (2016) Standard Test Method for Coefficient of Linear Thermal Expansion of Plastics Between -30 degrees C and 30 degrees C With a Vitreous Silica Dilatometer

ASTM D790 (2017) Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials

ASTM D2583 (2013a) Indentation Hardness of Rigid Plastics by Means of a Barcol Impressor

ASTM E84 (2020) Standard Test Method for Surface Burning Characteristics of Building Materials

ASTM G21 (2015; R 2021; E 2021) Standard Practice for Determining Resistance of Synthetic Polymeric Materials to Fungi

CALIFORNIA DEPARTMENT OF PUBLIC HEALTH (CDPH)

CDPH SECTION 01350 (2010; Version 1.1) Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources using Environmental Chambers

INTERNATIONAL CAST POLYMER ASSOCIATION (ICPA)

ICPA SS-1 (2001) Performance Standard for Solid Surface Materials

SECTION 06 61 16 Page 1

NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)

ANSI/NEMA LD 3 (2005) Standard for High-Pressure Decorative Laminates

NSF INTERNATIONAL (NSF)

NSF/ANSI 51 (2012) Food Equipment Materials

1.2 SYSTEM DESCRIPTION

a. Work under this section includes other items utilizing solid surfacing material fabrications as indicated on the drawings and as described in this specification. Do not change source of supply for materials after work has started, if the appearance of finished work would be affected.

b. In most instances, installation of solid surfacing material fabricated components and assemblies requires strong correctly located structural support provided by other trades. To provide a stable, sound, secure installation, close coordination is required between the solid surfacing material fabricator/installer and other trades to ensure that necessary structural wall support, cabinet counter top structural support, proper clearances, and other supporting components are provided for the installation of wall panels, counter tops, shelving, and all other solid surfacing material fabrications to the degree and extent recommended by the solid surfacing material manufacturer.

c. Provide appropriate staging areas for solid surfacing material fabrications. Allow variation in component size and location of openings of plus or minus 1/8 inch.

1.3 SUBMITTALS

Government approval is required for submittals with a "G" or "S" classification. Submittals not having a "G" or "S" classification are for Contractor Quality Control approval. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES:

SD-02 Shop Drawings

Detail Fabrication Drawings; G

Installation; G

SD-03 Product Data

Solid Polymer; G

Indoor air quality for solid surface seam and sealant products; S

SD-04 Samples

Solid Surfacing Material; G

Metal Trims; G

SD-06 Test Reports

SECTION 06 61 16 Page 2

Test Report Results

SD-07 Certificates

Qualifications

Indoor Air Quality for solid surface fabrication products; S

SD-10 Operation and Maintenance Data

Solid Polymer, Data Package 1; G

1.4 QUALITY ASSURANCE

1.4.1 Qualifications

To ensure warranty coverage, provide manufacturer certified solid surfacing fabricators to fabricate the solid surfacing material being utilized. Mark all fabrications with the fabricator's certification label affixed in an inconspicuous location. Minimum of 5 years of experience working with solid surfacing materials is required of fabricators. Submit solid surfacing material manufacturer's certification attesting to fabricator qualification approval.

1.5 DELIVERY, STORAGE, AND HANDLING

Do not deliver materials to project site until areas are ready for installation. Deliver components and materials to the site undamaged, in containers clearly marked and labeled with manufacturer's name. Store materials indoors and take adequate precautions to prevent damage to finished surfaces. Provide protective coverings to prevent physical damage or staining following installation, for duration of project.

1.6 WARRANTY

Provide manufacturer's warranty to repair or replace defective materials, excluding damages caused by physical or chemical abuse or excessive heat, and workmanship for a period of 10 years from date of final acceptance of the work.

PART 2 PRODUCTS

2.1 PRODUCT DATA, DETAIL FABRICATION DRAWINGS, OPERATIONS AND MAINTENANCE

DATA

Submit detail fabrication drawings and installation drawings of each solid surfacing fabrication indicated. Include elevations, dimensions, clearances, details of construction and anchorage, and details of joints and connections.

Submit manufacturers' descriptive product data for each type of solid polymer fabrication indicated. Include manufacturers' literature, finishes, profiles and thicknesses of materials.

Submit manufacturers' operations and maintenance data for each type of solid polymer fabrication in accordance with Section 01 78 23 OPERATIONS

AND MAINTENANCE DATA.

SECTION 06 61 16 Page 3

2.1.1 Solid Surfacing Material (SSM-1, 2, SWP-1)

Provide solid polymer that is a homogeneous filled solid polymer; not coated, laminated or of a composite construction, complying with ICPA SS-1 .

Provide material that meets or exceeds the minimum physical and performance properties specified. Superficial damage to a depth of 0.01 inch must be repairable by sanding or polishing. Material thickness is as indicated on the drawings. Submit a minimum 4 inch by 4 inch sample of each color and pattern for approval; include full range of color and pattern variation. Retain approved samples as a standard for this work.

Submit test report results from an independent testing laboratory attesting that the submitted solid surfacing materials meet or exceed each of the specified performance requirements.

a. Horizontal Surfaces: 1/2 inch thick material.

b. Vertical Surfaces: 1/2 inch thick material.

c. Provide materials that meet the emissions requirements of CDPH SECTION 01350 (limit requirements for either office or classroom spaces regardless of space type). Provide certification or validation of indoor air quality for solid surface fabrication products.

2.1.2 Cast, 100 Percent Acrylic Polymer Solid Surfacing Material (SSM, SWP, SPB)

Cast, 100 percent acrylic solid polymer material composed of acrylic polymer, mineral fillers, and pigments. Provide acrylic polymer that meets or exceeds the following minimum performance requirements:

PROPERTY REQUIREMENT

(min. or max.)

TEST PROCEDURE

Tensile Strength 4000 psi (max.) ASTM D638

Hardness 55-Barcol Impressor (min.) ASTM D2583

Thermal Expansion .000023 in/in/F (max.) ASTM D696

Boiling Water Surface Resistance

No Change ANSI/NEMA LD 3 -3.05

High Temperature Resistance

No Change ANSI/NEMA LD 3 -3.06

Impact Resistance (Ball drop) ANSI/NEMA LD 3 -303

1/2 inch sheet 140-inches, 1/2 lb ball, no failure

3/4 inch sheet 200-inches, 1/2 lb ball, no failure

SECTION 06 61 16 Page 4

PROPERTY REQUIREMENT

(min. or max.)

TEST PROCEDURE

Mold & Mildew Growth No growth ASTM G21

Bacteria Growth No growth ASTM G21

Liquid Absorption (Weight in 24 hrs.)

0.1 percent max. ASTM D570

Flammability ASTM E84

Flame Spread 25 max.

Smoke Developed 30 max.

Sanitation "Food Contact" approval NSF/ANSI 51

Flexural Strength 6,800 psi (min.) ASTM D790

2.1.3 Material Patterns and Colors

Provide pattern and color for all solid surfacing material components and fabrications as indicated. Provide products with consistent patterned color throughout thickness of the product.

2.1.4 Surface Finish

Provide a uniform appearance on exposed finished surfaces and edges.

Exposed surface finish is matte; gloss rating of 5-20.

2.2 ACCESSORY PRODUCTS

Provide accessory products, as specified below, as manufactured by the solid surfacing material manufacturer or as approved by the solid surfacing material manufacturer for use with the solid surfacing materials being specified.

2.2.1 Adhesives

Provide a two-part seam adhesive kit to create permanent, inconspicuous, non-porous, hard seams and joints by chemical bond between solid surfacing materials and components to create a monolithic appearance of the fabrication. Provide adhesive approved by the solid surfacing material manufacturer. Color-match adhesive to the surfaces being bonded where solid-colored, solid surfacing materials are being bonded together.

Provide clear or color matched seam adhesive where particulate patterned, solid surfacing materials are being bonded together.

2.2…