DI-033_REV_3_COMMUNICATIONS_REQUIREMENT_MATRIX.pdf

PDF 1 MB Posted

Attached to
NPS ISRO Ranger IV Vessel
Solicitation number
140PS125R0009
Issued by

About this file

This document is a Communications Requirements Matrix for the Preliminary/Contract Design of Motor Vessel Ranger IV, prepared by Loch Harbour Group for Contract No. 6913G623P800007. The matrix details both exterior and interior communication systems for the vessel, including comprehensive specifications for various communication equipment. Key exterior communication systems include multiple VHF radiotelephones, Inmarsat C systems, MF radio systems, cellular antennas, an aircraft transceiver, Iridium system, EPIRB, and other maritime communication technologies. The interior communication systems encompass sound power telephone systems, dial telephone systems, public address systems, fire alarm systems, and a Bridge Navigational Watch and Alarm System, with most equipment powered by 24VDC or 120VAC and designed to meet 46 CFR Subpart requirements.

View the file

Other files

File Type Posted
Sol_140PS125R0009_Amd_0004.pdf PDF
140PS125R0009_Amendment_004_Solicitation_Question_Response_0004.pdf PDF
140PS125R0009_Amendment_004_R4_ReeferSpaceConflict_0004.pdf PDF
DI-035_REV_8_BIDDING_SPECIFICATIONS_0004.pdf PDF
140PS125R0009_ISRO_Ranger_IV_Clause_Section__Amendment_Three_0003.pdf PDF
Sol_140PS125R0009_Amd_0003.pdf PDF
DI-004_REV5_DESIGN_SUMMARY_REPORT_0003.pdf PDF
140PS125R0009_Amendment_003_Solicitation_Question_Response_0003.pdf PDF
140PS125R0009_Amendment_002_Solicitation_Questions_Response_0002.pdf PDF
DI-035_REV_7_BIDDING_SPECIFICATIONS_0002.pdf PDF
Sol_140PS125R0009_Amd_0002.pdf PDF
Sol_140PS125R0009_Amd_0001.pdf PDF
DI-026-01_REV_6_GENERAL_ARRANGEMENT.pdf PDF
DI-019_REV_4_INTACT_AND_DAMAGE_STABILITY_REPORT_Pgs_601-1209.pdf PDF
J-9_Brand_Name_Justification_Ranger_IV_Honda.pdf PDF
DI-027-05_REV_1_AUTOMATION_CONTROL_AND_MONITORING_SYSTEM_REPORT.pdf PDF
DI-026-16_REV_7_ANCHORING_AND_MOORING_DRAWING.pdf PDF
DI-013_REV_3_SPEED_AND_POWER_REPORT.pdf PDF
DI-026-17_REV_0_STRUCTURAL_FIRE_PROTECTION_GUIDANCE_DRAWING.pdf PDF
J-4_Delivery_and_Acceptance_Certificate.pdf PDF
DI-017_REV_2_AIRBORNE_NOISE_REPORT.pdf PDF
J-8_Small_Business_Subcontracting_Plan.docx DOCX document
DI-006_REV_3_MASTER_EQUIPMENT_LIST.pdf PDF
DI-026-12_REV_4_PILOT_HOUSE-CHART_AREA_ARRANGEMENT.pdf PDF
DI-034_REV_6_HVAC_SYSTEM_REPORT.pdf PDF
DI-030_REV_5_ELECTRIC_POWER_LOAD_ANALYSIS.pdf PDF
DI-035_REV_6_BIDDING_SPECIFICATIONS.pdf PDF
DI-015_REV_2_MANEUVERING_PERFORMANCE_REPORT.pdf PDF
DI-029_REV_2_STACK_GAS_FLOW_ANALYSIS_REPORT.pdf PDF
DI-026-07_REV_1_SUPERSTRUCTURE_DRAWING-Published.pdf PDF
DI-011_REV_3_HULL_LINES_DRAWING.pdf PDF
DI-026-03_REV_2_MIDSHIP_SECTION_DRAWING-Published.pdf PDF
DI-026-04_REV_2_TYPICAL_SECTION_DRAWING-Published.pdf PDF
DI-023_REV_2_MODEL_TEST_REPORT.pdf PDF
DI-026-08_REV_3_MAST_AND_FLAGSTAFF_DRAWING.pdf PDF
DI-032_REV_2_PRELIMINARY_FAULT_CURRENT_ANALYSIS_REPORT.pdf PDF
DI-010_REV_1_ABS_ICE_CLASS_ANALYSIS.pdf PDF
DI-020_REV_2_WEIGHT_CONTROL_PLAN.pdf PDF
DI-026-13_REV_6_MACHINERY_ARRANGEMENT.pdf PDF
DI-012_REV_3_APPENDAGE_AND_CONTROL_SURFACE_DRAWING.pdf PDF
J-7_Past_Performance_Questionnaire.docx DOCX document
DI-026-07_REV_2_SUPERSTRUCTURE_DRAWING.pdf PDF
DI-004_REV_4_DESIGN_SUMMARY_REPORT.pdf PDF
J-6_Proposed_Equals_and_Salient_Characteristics.docx DOCX document
DI-007_REV_2_REQUIREMENTS_VERIFICATION_MATRIX.pdf PDF
DI-026-06_REV_3_DECK_AND_PLATFORM_DRAWING.pdf PDF
DI-031_REV_2_ELECTRICAL_SYSTEM_ONE_LINE_DIAGRAM.pdf PDF
J-5_Completion_and_Delivery_Certificate.pdf PDF
DI-014_REV_2_SEAKEEPING_PREFORMANCE_REPORT.pdf PDF
DI-026-15_REV_4_HANDLING_SYSTEMS_DRAWING.pdf PDF
Show 40 more

Latest 50 of 68 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Submitted by:

Loch Harbour Group 3060 Williams Drive, Suite 510

Fairfax, Virginia 22031

Preliminary/Contract Design of Motor Vessel Ranger IV

Contract No.: 6913G623P800007

CLIN-00100

DI-033 Communications Requirements Matrix Revision 3

Date: April 4, 2025

DISTRIBUTION Statement C: Distribution authorized to the U.S. Government agencies and their Contractors. Other requests for this document shall be referred to US Department of Transportation Volpe Center.

DATA RIGHTS: This report, drawing, design, concept, and specification are the intellectual property of Loch Harbour Group, LLC, and/or R.R.P CONSULTING ENGINEERS, L.L.C and contain information which is proprietary. The rights defined below are reserved by Loch Harbour Group, LLC, and/or R.R.P CONSULTING ENGINEERS, L.L.C.

The United States Government’s rights to use, modify, reproduce, release, perform, display, or disclose these technical data are unrestricted. Any reproduction of technical data or portions thereof marked with this legend must also reproduce the markings.

TABLE OF CONTENTS

DI-027-01 Area Volume Report Contract 6913G623P800007

ACRONYMS AND ABBREVIATIONS

REVISION TABLE

EXECUTIVE SUMMARY

A. ATTACHMENTS

Attachment A – Communications Requirements Matrix

Use or disclosure of the data contained on this sheet is subject to the restriction on the title page of this document. 2

ACRONYMS AND ABBREVIATIONS

ACRONYM DESCRIPTION

ABS American Bureau of Shipping CFR Code of Federal Regulations

DI Data Item DRL Data Requirements List LHG Loch Harbour Group SOW Statement of Work USCG United States Coast Guard

Use or disclosure of the data contained on this sheet is subject to the restriction on the title page of this document. 3

REVISION TABLE

REVISION DESCRIPTION DATE AUTHOR

0 Initial submission 01-19-24 LHG 1 Updated as per Engineering

Developments

06-19-24 LHG

2 Updated to address Government comments

07-05-24 LHG

3 Removed brand name information 04-04-25 VOLPE

Use or disclosure of the data contained on this sheet is subject to the restriction on the title page of this document. 4

EXECUTIVE SUMMARY

This document is submitted by Loch Harbour Group, 3060 Williams Drive, Suite 510, Fairfax, Virginia 22031, to satisfy CLIN 00100 DI-033 Communications Requirements Matrices, of Contract No. 6913G623P800007.

The objective of this report is to meticulously document and identify the interior and exterior communications requirements, communications systems and equipment including their capabilities. The matrix is presented to identify proposed equipment by manufacturer make and model numbers, frequency ranges and bandwidths along with the description of their usage.

Government REVIEW and COMMENT of this report is REQUIRED.

Use or disclosure of the data contained on this sheet is subject to the restriction on the title page of this document. 5

A. ATTACHMENTS

The following serves as supporting documentation for this report.

Attachment A – Communications Requirements Matrix.

RANGER IV EXTERIOR COMMUNICATION MATRICES

S.NO COMMUNICATION EQUIPMENT QUANTITY MAKE MODEL FREQUENCY RANGE

FREQUENCY

BANDWIDTH CIRCUIT USAGE REQUIREMENT

INMARSAT C Systems 2 --- ---

1626.5-1646.5 MHz (Tx) 1537.0-1646.5 MHz (RX)

130W (Tx), 60W (Rx)

(24VDC)

47 CFR § 80.905

VHF Radiotelephones with Digital Selective Calling

2 --- ---

(transmitter & Reciever) 155.000- 161.600MHz (Reciever sd) 159.600-164.200MHz

4.7A (Tx), 2.3A (Rx), 1.3A (Standby) (24VDC)

Basis of Design

MF Radio Systems 1 --- ---

1605.0-27500.0kHz (Tx) 100kHz-29999.99kHz (Rx)

20A (Tx), 5A (Rx) (24VDC)

VHF radiotelephones for survival craft 3 --- ---

156.300–156.875MHz

1A (Tx), 0.7A (Rx) (7.5VDC)

47 CFR § 80.1095

VHF radiotelephones capable of Tx and Rx

4 --- ---

156.025–157.425MHz (Tx) 156.050–163.275MHz (Rx) 156.525MHz (CH70)

5.5A (Tx), 1.5A (Rx)

(13.8VDC +/-15%)

Cellular Omni-Directional Antennas 2 --- ---

698 – 2700 MHz

100+ Mbps

5-15VDC 2.1A Max @

12VDC

7 Plain Paper Laser Printing Fax Machines 2 --- --- N/A 47 CFR § 80.1157

Aircraft transceiver

1 --- ---

118.0118.000–136.992MHz (Tx) 118.000–136.975MHz (Rx) 161.650–163.275MHz (Rx)

8.33kHz/25kHz

13.8V/27.5VDC

Cellular phone system, compatible with 4G LTE wireless services, with PABX/RJ-11 interface

698 – 2700 MHz

Iridium system, Sailor SC4300

1616 - 1626.5 MHz (Tx & Rx)

Approx. 4A avg/15A peak @ 12VDC, 2A avg/8A peak

@ 24VDC

11 VHF omni-directional antennas 3 --- --- 156-162 MHz 145-165 MHz 6dB gain 100W 47 CFR § 80.905

EPIRB 1 --- ---

406 MHZ CAT1

Lithium/iron disulfide, 12V/2900 mAh

46 CFR § 199.510

Integral Iridium based Ship Security Alert System (SSAS) 1 --- ---

9.2-9.5GHz Lithium metal 7,2V/3600 mAh

47 CFR § 80.277

14 LRIT System 1 --- --- N/A 33 CFR § 169.205 15 CLS (North American) SHIPLOC 1 --- --- N/A 47 CFR § 80.277

Public Address IP Speakers - Passenger Spaces

12 --- ---

N/A

10W

ABS MVR 4-8-2

46 CFR Subpart 113.50

RANGER IV INTERIOR COMMUNICATION MATRICES

S.NO COMMUNICATION EQUIPMENT QUANTITY MAKE MODEL FREQUENCY RANGE

FREQUENCY

BANDWIDTH CIRCUIT USAGE REQUIREMENT

Sound Power Telephone System

Circuit 1 VSP 1 --- ---

24VDC

46 CFR Subpart 113.30

Pilot House VSP 1 --- ---

Chart Area VSP 3 --- ---

Chart Area Headset 3 --- ---

Damage Control Lockers VSP 1 --- ---

Damage Control Lockers Headset 1 --- ---

Bow VSP 1 --- ---

Engine Room VSP 1 --- ---

Engine Control Room VSP 1 --- ---

Thruster Room 1 --- ---

Circuit 1 VSP 1 --- ---

Pilot House VSP 1 --- ---

Stowage Headsets 5 --- ---

Calling to 4 Stations 1 --- ---

VSP 4 --- ---

Dial Telephone System 1

2000W (110/208VAC)

Traditional Intercom Stations ---

Analogue Telephones ---

IP Intercoms, IP Telelphones or DECT Handset ---

Ip Station Licens For 6 Stations - Supports 6 Intercom Stations ---

Public Address System

UPS - 2 X 2880W (120VAC)

20.1

Public Address IP Speakers - Crew Spaces

20.2

Public Address IP Speakers - Passenger Spaces

Fire Alarm System --- --- ---

2.5A (125VAC)

46 CFR Subpart 113.10 - ABS 4-7

In Port Alarm and Monitoring System --- --- ---

N/A

15W, 10W, 5W, 2.5W (100V)

46 CFR Subpart 113.25

Bridge Navigational Watch and Alarm System 1 ---

100-230VAC, 24VDC

23 Master Alarm/Control Panel --- --- --- N/A N/A 100-230VAC, 24VDC 46 CFR Subpart 113.25 24 Processor Unit --- --- --- N/A N/A 100-230VAC, 24VDC 46 CFR Subpart 113.25 25 Timer Reset Panel --- --- --- N/A N/A 46 CFR Subpart 113.25 26 Cabin Alarm Panel --- --- --- N/A N/A 46 CFR Subpart 113.25 27 Waterproof Timer Reset Panel --- --- --- N/A N/A 46 CFR Subpart 113.25 28 Motion Detector --- --- --- N/A N/A 100-230VAC, 24VDC 46 CFR Subpart 113.25 29 Light Beacon --- --- --- N/A N/A 46 CFR Subpart 113.25

File details come from the government source that posted it. Updated .