This Construction Plans document supports Volusia County, Florida's electrical switchgear replacement project at the Daytona Beach Ocean Center (RFP 26-P-04LL, Contract No. C-2055). The project encompasses complete removal and replacement of the existing main-tie-main double-ended switchboard and associated bus duct systems, including installation of a new 480Y/277V, 3-phase, 4-wire service-entrance-rated Square D QED-2 model switchboard with 2000A capacity, copper busway distribution, grounding system upgrades, feeder replacements, arc flash studies compliant with IEEE 1584-2018 standards, and comprehensive testing protocols. Deliverables include shop drawings within 30 days of contract award, as-built AutoCAD documentation, comprehensive power system studies with short-circuit and protective device coordination analysis, manufacturer certifications, and one-year warranty on all work with extended warranties on metering devices (five years) and surge protective devices (ten years). A mandatory pre-solicitation conference is scheduled for March 10, 2026 (9:00 AM or 1:00 PM options) at the Ocean Center loading dock. Written questions must be submitted by March 26, 2026, with electronic proposals due through the County's eProcurement Portal by April 9, 2026 at 3:00 PM EST. The project must be substantially completed within 30 days of Notice to Proceed and fully completed within 35 days total.

Qualified prime contractors must hold an active Florida-licensed building or general contractor license with an active Florida Certified Electrical Contractor (EC) as subcontractor, a superintendent with active Florida Journeyman's Electrical License and minimum four years' experience, at least five years of established business history, and a minimum of three references demonstrating completion of similar switchgear replacement projects within the past three years. Evaluation criteria are weighted as follows: Technical Qualifications and Experience (35 percent), Project Approach and Schedule (35 percent), Price and Total Cost (20 percent), and Safety, Quality Control and Resources (10 percent). No set-asides for disadvantaged or minority-owned businesses are indicated. The contract price is listed as TBD with liquidated damages assessed at $1,000 per day for failure to meet the 35-day completion deadline. A payment and performance bond equal to 100 percent of the contract value is required prior to work commencement. Contractors must maintain comprehensive insurance including Workers' Compensation, Commercial General Liability ($1,000,000 per occurrence/$2,000,000 aggregate), Auto Liability ($1,000,000 combined single limit), and Excess Liability ($2,000,000), with the County named as additional insured and all policies issued by Florida-licensed insurers with A.M. Best ratings of A- or better.

View the file

Other files

Show all 19

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LOCATION MAP

REMOVAL OF EXISTING MAIN SWITCHGEAR AND PREPARE FOR INSTALLATION OF

NEW SWITCHGEAR.

© 2023 Google

VICINITY MAP

PROJECT LOCATION

© 2023 Google

Matern #2024-047

Copyright © Matern Professional Engineering, Inc. All Rights Reserved. 130 Candace Drive, Maitland, FL 32751 (407) 740-5020 (407) 740-0365/Fax www.matern.net CA License No. 5096

C op yr ig ht

M at er n

P ro fe ss io na l E ng in ee rin g, In c.

DRAWING INDEX

OCEAN CENTER

ELECTRICAL SWITCHGEAR

REPLACEMENT

MATERN NO. 2024-040

Ocean Center 101 N Atlantic Ave

Daytona Beach, FL 32118

APPLICABLE BUILDING CODES

— FLORIDA BUILDING CODE - EXISTING BUILDING - 8TH EDITION (2023)

— FLORIDA BUILDING CODE - ENERGY CONSERVATION - 8TH EDITION (2023)

— NFPA 70: NATIONAL ELECTRICAL CODE 2020

PROJECT SCOPE

DATE DOCUMENT PHASE

DESIGN TEAM

PRIME CONSULTANT: MEP

MATERN PROFESSIONAL ENGINEERING, INC.

130 Candace Drive Maitland, FL 32751 407.740.5020 CA License No. 5096 ENG. BUS. No. EB-0005096

— FLORIDA BUILDING CODE - BUILDING - 8TH EDITION (2023)

100% CD SUBMISSION05-13-2025

ELECTRICAL

E001 GENERAL NOTES, LEGENDS, & ABBREVIATIONS - ELECTRICAL

E101 ELECTRICAL PLAN - RENOVATION

E500 PARTIAL RISER DIAGRAM - ELECTRICAL

E100 OVERALL PLAN - ELECTRICAL

ED101 ELECTRICAL PLAN - DEMOLITION

E600 ELEVATIONS - ELECTRICAL

E900 DETAILS - ELECTRICAL

GENERAL PROJECT NOTES:

1. NOT ALL SYMBOLS ON ELECTRICAL SYMBOLS LIST ARE USED.

2. NO MULTI-WIRE BRANCH CIRCUITS ARE TO BE USED. EACH CIRCUIT IS TO HAVE SEPARATE INDIVIDUAL NEUTRAL.

3. ALL ELECTRICAL SYSTEMS INSTALLATIONS SHALL COMPLY WITH NFPA 70, AS WELL AS ALL APPLICABLE LOCAL CODES. IN

ADDITION, FIRE ALARM SYSTEM INSTALLATIONS SHALL COMPLY WITH NFPA 72.

4. DIVISION 26 CONTRACTOR SHALL COORDINATE ALL WORK WITH OTHER TRADES PRIOR TO AND DURING INSTALLATION.

5. DIVISION 26 CONTRACTOR SHALL NOT CUT, DRILL, OR IN ANY OTHER MANNER ALTER ANY STRUCTURAL MEMBER

WITHOUT PRIOR WRITTEN APPROVAL FROM A STRUCTURAL ENGINEER.

6. DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR FIRESTOPPING ALL PENETRATIONS THROUGH RATED WALLS AND FLOORS. DIVISION 26 CONTRACTOR SHALL BE RESPONSIBLE FOR WEATHERPROOFING ALL PENETRATIONS

THROUGH EXTERIOR WALLS OR ROOFS.

7. DIVISION 26 CONTRACTOR SHALL, BEFORE SUBMITTING PROPOSAL OR BID, EXAMINE ALL DRAWINGS AND SPECIFICATIONS RELATING TO THE PROJECT, THE AMOUNT OF SPACE AVAILABLE FOR ELECTRICAL EQUIPMENT, THE PROJECT SITE, THE REQUIREMENTS TO CORRELATE THE ELECTRICAL WORK WITH ALL OTHER TRADES, AND THE TIME

SCHEDULE NECESSARY TO PERFORM THAT WORK.

8. DIVISION 26 CONTRACTOR SHALL BASE THEIR PROPOSAL AND BID UPON THE EQUIPMENT AS SCHEDULED OR SPECIFIED, USING THE MANUFACTURERS AND MODEL NUMBERS AS CALLED FOR IN SPECIFICATIONS AND SCHEDULED ON THE DRAWINGS. IF MORE THAN ONE MANUFACTURER OF EQUIPMENT IS SPECIFIED, ANY ONE OF THE MANUFACTURERS OF EQUIPMENT MAY BE USED IN THE CONTRACTOR'S PROPOSAL. IF THIS CONTRACTOR WISHES TO USE EQUIPMENT NOT SPECIFIED, THEY MUST, AT THE TIME OF BIDDING, SUBMIT SEPARATELY ON LETTERHEAD STATIONARY OF THE BIDDER, THE EQUIPMENT THEY WOULD LIKE SUBSTITUTE AND THE COST TO BE DEDUCTED FROM HIS PROPOSAL.

9. DIVISION 26 CONTRACTOR IS RESPONSIBLE FOR ORDERING ALL MATERIALS IN SUFFICIENT TIME TO AVOID DELAYING THE COMPLETION OF THE PROJECT. DELAY IN DELIVERIES SHALL NOT BE CONSIDERED A JUSTIFIABLE REASON FROM

SUBMISSION OF SUBSTITUTE MATERIALS.

10. DIVISION 26 CONTRACTOR SHALL GIVE A MINIMUM OF 48 HOURS NOTICE, IN WRITING, TO AND RECEIVE WRITTEN APPROVAL FROM THE BUILDING OWNER (OR HIS REPRESENTATIVE) PRIOR TO SHUT DOWN OF ANY SYSTEM OR DISRUPTION OF SERVICE TO ANY AREA. CONTRACTOR SHALL ALSO COORDINATE THE EXACT LOCATION AND TIMING OF SYSTEM SHUTDOWN POINTS WITH THE OWNER (OR HIS REPRESENTATIVE). CONTRACTOR SHALL MAKE EVERY EFFORT

POSSIBLE TO MINIMIZE THE DURATION OF ANY DOWNTIME OR DISRUPTION PERIOD.

11. VISIT AND CAREFULLY EXAMINE THOSE PORTIONS OF THE SITE AFFECTED BY THIS WORK BEFORE SUBMITTING PROPOSALS, SO AS TO BECOME FAMILIAR WITH EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT EXECUTION OF THE WORK. SUBMISSION OF A PROPOSAL WILL BE CONSTRUED AS EVIDENCE THAT SUCH EXAMINATION HAS BEEN MADE AND LATER CLAIMS FOR LABOR, EQUIPMENT OR MATERIALS REQUIRED BECAUSE OF DIFFICULTIES

ENCOUNTERED WILL NOT BE RECOGNIZED.

12. COMPLY WITH SPECIFICATIONS.

13. ALL EMPTY CONDUITS ARE TO HAVE PULL-STRINGS PROVIDED IN THEM.

14. NO SPLICES SHALL BE MADE IN UNDERGROUND (OR FLUSH) IN-GRADE PULL BOXES UNLESS ENGINEER HAS GIVEN

SPECIFIC ACCEPTANCE.

15. ALL CONDUIT TERMINATIONS AT TERMINAL BOARDS ARE TO HAVE BUSHED CONDUIT ENDS.

16. SPLICES IN POWER AND LIGHTING OUTLET BOXES SHALL BE KEPT TO A MINIMUM, PULL CONDUCTORS THROUGH TO DEVICES, EQUIPMENT CABINETS/PANELBOARDS. SPLICING IN WIREWAYS IS NOT PERMITTED UNLESS SPECIAL WRITTEN

PERMISSION IS GRANTED BY A/E.

17. CONTRACTOR SHALL INCLUDE IN HIS BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF ALL WASTE MATERIALS GENERATED BY THIS PROJECT IN ACCORDANCE WITH ALL RULES, REGULATIONS AND GUIDELINES APPLICABLE.

CONTRACTOR SHALL COMPLY FULLY WITH FLORIDA STATUTE 403.7186 REGARDING MERCURY CONTAINING DEVICES AND LAMPS. LAMPS, BALLASTS AND OTHER MATERIALS SHALL BE TRANSPORTED AND DISPOSED OF IN ACCORDANCE WITH ALL DEP AND EPA GUIDELINES APPLICABLE AT TIME OF DISPOSAL. CONTRACTOR SHALL PROVIDE OWNER WITH

WRITTEN CERTIFICATION OF ACCEPTED DISPOSAL.

18. WORK TO BE PERFORMED IN STRICT COMPLIANCE WITH ESTABLISHED WORK SCHEDULE BEING SET FORTH BY OWNER.

COORDINATE ALL WORK. THE CONTRACTOR SHALL FURNISH ADEQUATE FORCES, CONSTRUCTION PLANT, AND EQUIPMENT, AND SHALL WORK SUCH HOURS, INCLUDING NIGHT SHIFTS, OVERTIME OPERATIONS, SUNDAY, AND HOLIDAYS IN ACCORDANCE WITH THE OWNERS OPERATIONAL SCHEDULE. IF THE CONTRACTOR FALLS BEHIND PROGRESS REQUIRED IN THE OPERATIONAL SCHEDULE, THE CONTRACTOR SHALL TAKE SUCH STEPS AS MAY BE NECESSARY TO IMPROVE HIS PROGRESS, AND THE OWNER MAY REQUIRE HIM TO INCREASE THE NUMBER OF SHIFTS AND/OR OVERTIME OPERATIONS, DAY OF WORK AND/OR THE AMOUNT OF CONSTRUCTION PLANT, AT NO ADDITIONAL COST TO THE OWNER UNDER THIS CONTRACT. (IT SHALL BE UNDERSTOOD THAT SEVERAL BID PACKAGES MAY BE CONSTRUCTED BY VARIOUS CONTRACTOR/SUB-CONTRACTORS WITHIN THE SAME WORK SPACE SIMULTANEOUSLY.)

19. USE OF MC CABLE IS NOT ACCEPTABLE.

20. ALL CIRCUITS AND WIRING DEVICES SHALL BE RATED A MINIMUM OF 20 AMPS.

21.IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO LOCATE ALL EXISTING UTILITIES WHETHER SHOWN ON PLANS OR NOT AND TO PROTECT THEM FROM DAMAGE. THE CONTRACTOR SHALL BEAR ALL EXPENSE FOR REPAIR OR REPLACEMENT OF UTILITIES OR OTHER PROPERTY DAMAGED BY OPERATIONS IN CONJUNCTION WITH THE COMPLETION OF THIS WORK. THE CONTRACTOR SHALL LOCATE ALL UTILITIES (BOTH KNOWN AND UNKNOWN) IN AREA OF WORK PRIOR TO EXCAVATION WITH THE USE OF ELECTRONIC LOCATOR/TRACER DEVICES AND EQUIPMENT

SUITABLE FOR SUCH USE. REFLECT LOCATED UTILITIES ON AS-BUILT DOCUMENTS.

22. COORDINATE EXACT LOCATION OF LIGHTING FIXTURES IN ALL MECH. ROOMS, AND SPACES WITH NO CEILING (EXPOSED STRUCTURE AREAS), SPACES, ETC., WITH DUCTWORK INSTALLER PRIOR TO ROUGH-IN. LOCATE BELOW DUCTWORK

(8'-0" A.F.F. MINIMUM) CENTERED IN ROOM AS MUCH AS FEASIBLE.

23.REFER TO EQUIPMENT SCHEDULES, FOR RESPECTIVE CONDUIT/CONDUCTORS, DISCONNECTS, MISC. EQUIPMENT REQUIRED FOR ALL EQUIPMENT. REFER TO PANEL SCHEDULES FOR CIRCUITS NUMBERS OF CIRCUITS FOR ALL EQUIPMENT. CONTRACTOR TO CONFIRM ALL REQUIRED ELECTRICAL ITEMS WITH FINAL EQUIPMENT SELECTIONS

PRIOR TO ELECTRICAL ROUGH-IN.

24. WHERE CONDUIT ROUTING IS SHOWN, THE CONDUITS ARE SHOWN FOR DIAGRAMMATIC PURPOSES AND ARE NOT NECESSARILY REPRESENTATIVE OF EXACT PLACEMENT. THE ROUTINGS SHOWN ARE PROPOSED CONDUIT ROUTINGS.

CONTRACTOR TO COORDINATE ALL ROUTING WITH OTHER TRADES PRIOR TO BID. CONTRACTOR TO FIELD VERIFY EXISTING CONDITIONS AND ROUTING OF CONDUIT PRIOR TO BID. CONTRACTOR IS RESPONSIBLE FOR RELOCATING CONDUIT FROM THE PROPOSED ROUTING SHOWN TO THE ROUTING REQUIRED TO FACILITATE INSTALLATION PER SPECIFICATIONS AND APPLICABLE CODES, COMPLETE WITH ALL COORDINATION AND EXISTING CONDITIONS TAKEN INTO ACCOUNT. CONTRACTOR IS RESPONSIBLE FOR ALL CEILING AND WALL REPAIR/REPLACEMENT AFTER ROUTING OF

CONDUIT.

25. THE PLANS REFLECT SYSTEMS VOLTAGE DROPS AS PER FBC ENERGY CONSERVATION 2023 8TH EDITION C505.73 FEEDER CONDUCTORS ARE SIZED FOR MAXIMUM VOLTAGE DROP OF 2 PERCENT AT DESIGN LOAD. BRANCH CIRCUIT CONDUCTORS ARE SIZED FOR A MAXIMUM VOLTAGE DROP OF 3 PERCENT AT DESIGN LOAD. CONTRACTOR SHALL

CONFIRM FINAL VOLTAGE DROP CALCULATIONS BASED ON FINAL INSTALLED ROUTINGS.

26. CONTRACTOR TO SUBMIT 1/4 INCH SCALE DRAWINGS OF ALL ELECTRICAL AND COMMUNICATIONS ROOMS SHOWING COORDINATION BETWEEN ALL DISCIPLINES/EXISTING CONDITIONS FOR REVIEW BY A/E PRIOR TO INSTALLATION.

GENERAL DEMOLITION PROJECT NOTES:

1. PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE DEMOLITION WORK. THIS CONTRACTOR SHALL PARTICIPATE IN THE SURVEY OF EXISTING

ELECTRICAL SERVICES.

2. ELECTRICAL CONTRACTOR SHALL DISCONNECT AND CAP ALL ELECTRICAL SERVICES HAZARD OR CAUSING DISRUPTION OF SERVICES IN ADJOINING AREAS. ANY SUCH AREAS IN QUESTION AND NOT SHOWN ON

DRAWING SHALL BE INVESTIGATED PRIOR TO REMOVAL.

3. WHEN A COMPLETE POWER CIRCUIT IS TO BE REMOVED, CONTRACTOR SHALL TURN OFF CIRCUIT BREAKER, REMOVE ALL ASSOCIATED WIRE BACK TO PANEL, AND MARK CIRCUIT BREAKER AS SPARE. EXISTING CONDUIT SYSTEMS SHALL REMAIN TO BE REUSED FOR NEW WORK, IF IN LIKE NEW CONDITION. WHEN A PARTIAL POWER CIRCUIT IS REMOVED, THE CONTRACTOR SHALL REMOVE ALL ASSOCIATED CONDUIT AND WIRE BACK TO THE NEAREST JUNCTION BOX, CAP OFF CONDUCTORS, AND LABEL WITH CIRCUIT NUMBER.

MAINTAIN ALL CIRCUIT CONTINUITY FOR PARTIAL CIRCUIT REMOVAL. PROVIDE OWNER WITH ONE

ADDITIONAL COPY OF EACH PANEL DIRECTORY UPON COMLETION OF WORK.

4. ALL CIRCUITS AND FEEDERS PASSING THROUGH AND SERVING UNDISTURBED AREAS (SHOWN OR NOT SHOWN) SHALL BE MAINTAINED. RESTORE THESE CIRCUITS IN AREAS INTERRUPTED BY DEMOLITION OR IN

THE PATH OF NEW CONSTRUCTION.

5. DEVICES, FIXTURES, AND CONNECTIONS SHOWN ON THE DEMOLITION PLAN ARE INTENDED TO GIVE THE CONTRACTOR A GENERAL IDEA OR COUNT OF WHAT EQUIPMENT IS BEING REMOVED, DISCONNECTED, OR RETAINED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD INSPECTION OF THE SITE TO DETERMINE ACTUAL CONDITIONS OF THE INSTALLATION AND QUANTITIES OF THE EXISTING EQUIPMENT BEFORE

SUBMITTING BID.

6. IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO PROTECT AND MAINTAIN THE INTEGRITY OF REMAINING DEVICES OR EQUIPMENT. CONNECTIONS SHALL BE CONCEALED UNLESS LOCATED IN

UNFINISHED AREA.

7. IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO PROPERLY SUPPORT EXISTING CONDUIT

AND LABEL JUNCTION BOXES, ETC. PASSING THROUGH RENOVATED AREAS.

8. PORTIONS OF THE EXISTING BUILDING ARE TO REMAIN IN OPERATION DURING CONSTRUCTION.

ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK THAT WILL INTERFERE WITH THE OPERATION OF THE FACILITY, WITH THE OWNER'S REPRESENTATIVE AND CONSTRUCTION MANAGER. ELECTRICAL

CONTRACTOR SHALL PROVIDE TEMPORARY POWER TO ALL EQUIPMENT THAT MUST REMAIN IN

OPERATION.

9. DURING THE DEMOLITION AND ALTERATION, THE FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION.

10. THE CONTRACTOR SHALL NOT ABANDON FEEDER OR BRANCH CIRCUIT WIRING IN EXISTING WALLS AND CEILINGS. CONTRACTOR SHALL FIELD VERIFY ALL FEEDERS AND MAINTAIN THE CONTINUITY OF THE FEEDERS AND BRANCH CIRCUIT WIRING TO ALL AREAS WHICH ARE TO REMAIN BUT THAT ARE AFFECTED BY

THE DEMOLITION OR NEW CONSTRUCTION.

11. INVENTORY ALL ELECTRICAL ITEMS THAT ARE REMOVED AND PROVIDE A LIST TO THE OWNER FOR THEIR SELECTION OF ITEMS TO BE RETAINED. ALL ITEMS REJECTED BY THE OWNER SHALL BECOME THE PROPERTY

OF THE CONTRACTOR AND SHALL BE REMOVED FROM THE SITE.

Drawing No.

Drawing Title:

Designed By:

Drawn By:

Checked By:

Issue Date:

Drawing Scale:

Key Plan

Revisions No.

100% CD SUBMITTAL

05-13-2025

OCEAN CENTER

ELECTRICAL

SWITCHGEAR

REPLACEMENT

MPE PROJ#: 2024-040

THIS DRAWING IS THE PROPERTY OF MATERN PROFESSIONAL

ENGINEERING, INC. UNLESS OTHERWISE PROVIDED BY THE

CONTRACT, THE CONTENTS OF THIS DRAWING SHALL NOT BE

TRANSMITTED TO ANY OTHER PARTY EXCEPT AS AGREED TO

BY THE ENGINEER.

FAX (407) 740-0365

PHONE (407) 740-5020

CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096

130 Candace Drive Maitland, FL 32751

Date Description

101 N ATLANTIC AVE.

DAYTONA BEACH, FL 32118

APP

APP

BP

NTS

GENERAL NOTES,

LEGEND, &

ABBREVIATIONS

ELECTRICAL

E001

AutoCAD SHX Text

H.S. - HEAT STRIP

AutoCAD SHX Text

KW - KILOWATTS

AutoCAD SHX Text

HPS - HIGH PRESSURE SODIUM

AutoCAD SHX Text

IMC - INTERMEDIATE METALLIC CONDUIT

AutoCAD SHX Text

L.L.D. - LAMP LUMEN DEPRECIATION

AutoCAD SHX Text

LED - LIGHT EMITTING DIODE

AutoCAD SHX Text

LIU - LIGHT INTERFACE UNIT

AutoCAD SHX Text

HZ - HERTZ (CYCLES)

AutoCAD SHX Text

HPF - HIGH POWER FACTOR

AutoCAD SHX Text

HP. - HORSEPOWER

AutoCAD SHX Text

INCAND. - INCANDESCENT

AutoCAD SHX Text

J.B. - JUNCTION BOX

AutoCAD SHX Text

KVA - KILOVOLT AMPERE

AutoCAD SHX Text

KWH - KILOWATT HOUR

AutoCAD SHX Text

K - KELVIN

AutoCAD SHX Text

HT - HEIGHT

AutoCAD SHX Text

HR. - HOUR

AutoCAD SHX Text

IN. - INCHES

AutoCAD SHX Text

4X - STAINLESS STEEL DUSTIGHT, WATERTIGHT

AutoCAD SHX Text

W.P. - WEATHERPROOF

AutoCAD SHX Text

XFMR - TRANSFORMER

AutoCAD SHX Text

W - WIRE

AutoCAD SHX Text

YD. - YARD

AutoCAD SHX Text

YR. - YEAR

AutoCAD SHX Text

3R - RAINPROOF

AutoCAD SHX Text

Y - WYE

AutoCAD SHX Text

CLG. - CEILING

AutoCAD SHX Text

CU. - COPPER

AutoCAD SHX Text

DWG - DRAWING

AutoCAD SHX Text

ELEV. - ELEVATOR

AutoCAD SHX Text

FLR - FLOOR

AutoCAD SHX Text

EST - ESTIMATE

AutoCAD SHX Text

GAL. - GALLON

AutoCAD SHX Text

GND. - GROUND

AutoCAD SHX Text

HTG - HEATERS

AutoCAD SHX Text

C.R.I. - COLOR RENDERING INDEX

AutoCAD SHX Text

C.T. - CURRENT TRANSFORMER

AutoCAD SHX Text

C.U. - COMPRESSOR CONDENSER UNIT

AutoCAD SHX Text

DPST - DOUBLE POLE SINGLE THROW

AutoCAD SHX Text

E.C. - ELECTRICAL CONTRACTOR (OR GENERAL CONTRACTOR)

AutoCAD SHX Text

EMT - ELECTRIC METALLIC TUBING

AutoCAD SHX Text

FAAP - FIRE ALARM ANNUNCIATOR PANEL

AutoCAD SHX Text

FACP - FIRE ALARM CONTROL PANEL

AutoCAD SHX Text

FATC - FIRE ALARM TERMINAL CABINET

AutoCAD SHX Text

FCCP - FIRE ALARM COMMAND CENTER PANEL

AutoCAD SHX Text

FIDS - FLIGHT INFORMATION DISPLAY SYSTEM

AutoCAD SHX Text

FVNR - FULL VOLTAGE NON-REVERSING

AutoCAD SHX Text

GPM - GALLONS PER MINUTE

AutoCAD SHX Text

GFI - GROUND FAULT INTERRUPTING

AutoCAD SHX Text

GRS - GALVANIZED RIGID STEEL CONDUIT

AutoCAD SHX Text

FHC - FIRE HOSE CABINET

AutoCAD SHX Text

FLA - FULL LOAD AMPERES

AutoCAD SHX Text

F.C. - FOOTCANDLES

AutoCAD SHX Text

GALV. - GALVANIZED

AutoCAD SHX Text

GPH - GALLONS PER HOUR

AutoCAD SHX Text

COMP. - COMPRESSOR

AutoCAD SHX Text

CONN. - CONNECTION

AutoCAD SHX Text

COND. - CONDENSER

AutoCAD SHX Text

CONT. - CONTINUOUS

AutoCAD SHX Text

C.W. - COLD WATER

AutoCAD SHX Text

D.B. - DIRECT BURIAL

AutoCAD SHX Text

D.C. - DIRECT CURRENT

AutoCAD SHX Text

DISC. - DISCONNECT

AutoCAD SHX Text

EQUIP. - EQUIPMENT

AutoCAD SHX Text

FT. - FEET

AutoCAD SHX Text

DN. - DOWN

AutoCAD SHX Text

AL - ALUMINUM

AutoCAD SHX Text

ALT - ALTERNATE

AutoCAD SHX Text

AMP - AMPERE

AutoCAD SHX Text

BLDG - BUILDING

AutoCAD SHX Text

BRKR - BREAKER

AutoCAD SHX Text

C. - CONDUIT

AutoCAD SHX Text

CD. - CANDELA

AutoCAD SHX Text

CKT. - CIRCUIT

AutoCAD SHX Text

A/E - ARCHITECT/ENGINEER (OR ENGINEER WHEN

AutoCAD SHX Text

A.C. - ALTERNATING CURRENT

AutoCAD SHX Text

AFD - ADJUSTABLE FREQUENCY DRIVE

AutoCAD SHX Text

AFF - ABOVE FINISHED FLOOR

AutoCAD SHX Text

AFG - ABOVE FINISHED GRADE

AutoCAD SHX Text

AIC - AMPS INTERRUPTING CAPACITY

AutoCAD SHX Text

ANSI - AMERICAN NATIONAL STANDARDS INSTITUTE

AutoCAD SHX Text

AWG - AMERICAN WIRE GAUGE

AutoCAD SHX Text

BIDS - BAGGAGE INFORMATION DISPLAY SYSTEM

AutoCAD SHX Text

BTU - BRITISH THERMAL UNIT

AutoCAD SHX Text

CBM - CERTIFIED BALLAST MANUFACTURERS

AutoCAD SHX Text

CFM - CUBIC FEET PER MINUTE

AutoCAD SHX Text

CKT BRKR - CIRCUIT BREAKER

AutoCAD SHX Text

B.C. - BARE COPPER

AutoCAD SHX Text

BTUH - BTU PER HOUR

AutoCAD SHX Text

C.B. - CIRCUIT BREAKER

AutoCAD SHX Text

C/L - CENTER LINE

AutoCAD SHX Text

ARCHITECT NOT APPLICABLE)

AutoCAD SHX Text

A/C - AIR CONDITIONING

AutoCAD SHX Text

ADD # - ADDENDA #

AutoCAD SHX Text

AHU - AIR HANDLER UNIT

AutoCAD SHX Text

@ - AT

AutoCAD SHX Text

%%UELECTRICAL ABBREVIATIONS

AutoCAD SHX Text

OS&Y - OUTSIDE SCREW AND YOKE (SPRINKLER)

AutoCAD SHX Text

SWBD - SWITCHBOARD

AutoCAD SHX Text

TEMP. - TEMPERATURE

AutoCAD SHX Text

SPST - SINGLE POLE SINGLE THROW

AutoCAD SHX Text

THHN; - THWN NYLON JACKETED WIRE

AutoCAD SHX Text

TTB - TELEPHONE TERMINAL BOARD

AutoCAD SHX Text

TTC - TELEPHONE TERMINAL CABINET

AutoCAD SHX Text

TVTC - TELEVISION TERMINAL CABINET

AutoCAD SHX Text

TVEC - TELEVISION EQUIP. CABINET

AutoCAD SHX Text

U.L. - UNDERWRITERS' LABORATORIES

AutoCAD SHX Text

VFD - VARIABLE FREQUENCY DRIVE

AutoCAD SHX Text

VHF - VERY HIGH FREQUENCY

AutoCAD SHX Text

VHO - VERY HIGH OUTPUT

AutoCAD SHX Text

VA - VOLT AMPERES

AutoCAD SHX Text

V - VOLT

AutoCAD SHX Text

TYP - TYPICAL

AutoCAD SHX Text

VOL. - VOLUME

AutoCAD SHX Text

SF - SQUARE FOOT

AutoCAD SHX Text

SW. - SWITCH

AutoCAD SHX Text

SYS. - SYSTEM

AutoCAD SHX Text

TV - TELEVISION

AutoCAD SHX Text

S/N - SOLID NEUTRAL

AutoCAD SHX Text

PL - COMPACT FLUORESCENT LAMP

AutoCAD SHX Text

P.T. - POTENTIAL TRANSFORMER

AutoCAD SHX Text

PSF - POUNDS PER SQUARE FOOT

AutoCAD SHX Text

PSI - POUNDS PER SQUARE INCH

AutoCAD SHX Text

PVC - POLYVINYL CHLORIDE

AutoCAD SHX Text

RECEPT. - RECEPTACLE

AutoCAD SHX Text

RPM - REVOLUTIONS PER MINUTE

AutoCAD SHX Text

SCA - SHORT CIRCUIT AMPS

AutoCAD SHX Text

PR - PAIR

AutoCAD SHX Text

PRI. - PRIMARY

AutoCAD SHX Text

R.S. - RAPID START

AutoCAD SHX Text

SEC. - SECONDARY

AutoCAD SHX Text

SHT - SHEET

AutoCAD SHX Text

% - PERCENT

AutoCAD SHX Text

/ - PHASE

AutoCAD SHX Text

P. - POLE

AutoCAD SHX Text

PB - PULLBOX

AutoCAD SHX Text

PNL - PANEL

AutoCAD SHX Text

NEMA - NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

AutoCAD SHX Text

NFPA - NATIONAL FIRE PROTECTION ASSOCIATION

AutoCAD SHX Text

MCM - THOUSAND CIRCULAR MILS

AutoCAD SHX Text

MPH - MILES PER HOUR

AutoCAD SHX Text

MCP - MOTOR CIRCUIT PROTECTOR

AutoCAD SHX Text

NEC - NATIONAL ELECTRIC CODE

AutoCAD SHX Text

N.P.T. - NATIONAL PIPE THREAD

AutoCAD SHX Text

N.O. - NORMALLY OPEN

AutoCAD SHX Text

N.C. - NORMALLY CLOSED

AutoCAD SHX Text

NIC. - NOT IN CONTRACT

AutoCAD SHX Text

OD - OUTSIDE DIAMETER

AutoCAD SHX Text

NF - NON FUSED

AutoCAD SHX Text

NO. - NUMBER

AutoCAD SHX Text

OB - OUTLET BOX

AutoCAD SHX Text

O.L. - OVERLOAD

AutoCAD SHX Text

OLS - OVERLOADS

AutoCAD SHX Text

MM - MILLIMETER

AutoCAD SHX Text

MIN. - MINIMUM

AutoCAD SHX Text

MTD - MOUNTED

AutoCAD SHX Text

N. - NEUTRAL

AutoCAD SHX Text

MAINT. - MAINTENANCE

AutoCAD SHX Text

L.P.F. - LOW POWER FACTOR

AutoCAD SHX Text

M.C.B. - MAIN CIRCUIT BREAKER

AutoCAD SHX Text

M.L.O. - MAIN LUGS ONLY

AutoCAD SHX Text

MH. - MANHOLE; METAL HALIDE

AutoCAD SHX Text

MFG. - MANUFACTURER

AutoCAD SHX Text

LT. - LIGHT

AutoCAD SHX Text

LTG. - LIGHTING

AutoCAD SHX Text

LTS. - LIGHTS

AutoCAD SHX Text

MAX. - MAXIMUM

AutoCAD SHX Text

MOCP - MINIMUM OVERCURRENT PROTECTION

AutoCAD SHX Text

120/208V BRANCH CIRCUIT PANELBOARD SURFACE MOUNTED

AutoCAD SHX Text

SQUARE "D"

AutoCAD SHX Text G.E.

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text i

AutoCAD SHX Text

277/480V BRANCH CIRCUIT PANELBOARD SURFACE MOUNTED

AutoCAD SHX Text

SQUARE "D"

AutoCAD SHX Text G.E.

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text i

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text

TRANSFORMER

AutoCAD SHX Text

SQUARE "D"

AutoCAD SHX Text G.E.

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text i

AutoCAD SHX Text

INTEGRATED FACILITIES SWITCHBOARD (IFS)

AutoCAD SHX Text

SQUARE "D"

AutoCAD SHX Text G.E.

AutoCAD SHX Text

SIEMENS

AutoCAD SHX Text

AUTOMATIC TRANSFER SWITCH

AutoCAD SHX Text

RUSSELECTRIC

AutoCAD SHX Text

ASCO

AutoCAD SHX Text i

AutoCAD SHX Text

CONDUIT CAPPED OFF

AutoCAD SHX Text

CONDUIT CONTINUED

AutoCAD SHX Text

CONDUIT RUN UP

AutoCAD SHX Text

CONDUIT RUN DOWN

AutoCAD SHX Text

APPROVED SUBSTITUTION

AutoCAD SHX Text

SYMBOL

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SYMBOL LEGEND

AutoCAD SHX Text

DESIGN SELECTION

AutoCAD SHX Text

APPROVED SUBSTITUTION

AutoCAD SHX Text

REMARKS

AutoCAD SHX Text NOTES: 1) SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. 2) ALL ITEMS NOTED ON THE LEGENDS DO NOT NECESSARILY APPEAR ON PLANS. ALL ITEMS NOTED ON THE LEGENDS DO NOT NECESSARILY APPEAR ON PLANS. REMARKS: i) MAINTAIN WORKING CLEARANCES IN STRICT ACCORDANCE WITH N.E.C. COORDINATE EXACT LOCATION OF EQUIPMENT WITH ALL DISCIPLINES (I.E. STRUCTURAL, HVAC, PLUMBING, FIRE PROTECTION, KITCHEN, MILLWORK, ETC.) PRIOR TO ROUGH-IN TO MAINTAIN CLEARANCES.

WOMEN

T.

EXHIBIT HALL ARENA

SCOPE OF WORK AREA

REFER TO ENLARGED PLANS ED101/E101

PIN-EXD1

L3N-EXD1

RIN-EXD1

RIN-EXA2

P3N-EXB1

T1N-MZB1

(LOCATED ON MEZZANINE LEVEL)

M4N-MZA1

(LOCATED ON MEZZANINE LEVEL)

RIN-MZA1

(LOCATED ON MEZZANINE LEVEL)

RIN-MZA3

(LOCATED ON MEZZANINE LEVEL)

M4N-MZD1

(LOCATED ON MEZZANINE LEVEL)

RIN-MZD2

(LOCATED ON MEZZANINE LEVEL)

R/D-MZD1

RIN-MZD1

(LOCATED ON MEZZANINE LEVEL)

RIN-EXA3

PIN-EXA1

M4N-EXD1

EX-5

Drawing No.

Drawing Title:

Designed By:

Drawn By:

Checked By:

Issue Date:

Drawing Scale:

Key Plan

Revisions No.

100% CD SUBMITTAL

05-13-2025

OCEAN CENTER

ELECTRICAL

SWITCHGEAR

REPLACEMENT

MPE PROJ#: 2024-040

THIS DRAWING IS THE PROPERTY OF MATERN PROFESSIONAL

ENGINEERING, INC. UNLESS OTHERWISE PROVIDED BY THE

CONTRACT, THE CONTENTS OF THIS DRAWING SHALL NOT BE

TRANSMITTED TO ANY OTHER PARTY EXCEPT AS AGREED TO

BY THE ENGINEER.

FAX (407) 740-0365

PHONE (407) 740-5020

CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096

130 Candace Drive Maitland, FL 32751

Date Description

101 N ATLANTIC AVE.

DAYTONA BEACH, FL 32118

APP/BP

APP

BP

1/32" - 1'-0"

OVERALL PLAN

ELECTRICAL

E100

OVERALL PLAN

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text

UP

AutoCAD SHX Text 06/01/05

AutoCAD SHX Text 06/01/05

AutoCAD SHX Text

DIAPER

AutoCAD SHX Text

STATION

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

FEC

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

PLATE

AutoCAD SHX Text

PRODNAME

AutoCAD SHX Text

PRODCLASS

AutoCAD SHX Text

MATERIAL

AutoCAD SHX Text

KPG

AutoCAD SHX Text

RIPG

AutoCAD SHX Text

USER1

AutoCAD SHX Text

USER2

AutoCAD SHX Text

USER3

AutoCAD SHX Text

FEC

AutoCAD SHX Text

ELECTRICAL ROOM

AutoCAD SHX Text

HEATING/COOLING PLANT

AutoCAD SHX Text

SERVICE YARD

AutoCAD SHX Text

COOLING TOWERS

AutoCAD SHX Text

BUILDING MAINTENANCE

AutoCAD SHX Text

PHONE LINES

AutoCAD SHX Text

TRANSFORMER VAULT

AutoCAD SHX Text 2"

AutoCAD SHX Text 2"

AutoCAD SHX Text 8"

AutoCAD SHX Text 8"

AutoCAD SHX Text

AutoCAD SHX Text 0"

AutoCAD SHX Text 4 3/4"

AutoCAD SHX Text 3' 0"

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text 6"

AutoCAD SHX Text

AutoCAD SHX Text 1 3/4"

AutoCAD SHX Text 0"

AutoCAD SHX Text 0"

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3' 0"

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 2:6

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:0

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 2:6

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:8.5

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:8.5

AutoCAD SHX Text :2

AutoCAD SHX Text :2

AutoCAD SHX Text :8

AutoCAD SHX Text :8

AutoCAD SHX Text

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:8.5

AutoCAD SHX Text Standard

AutoCAD SHX Text Hinged

AutoCAD SHX Text :6

AutoCAD SHX Text

AutoCAD SHX Text :1ƒ

AutoCAD SHX Text :0

AutoCAD SHX Text :0

AutoCAD SHX Text

WALLTHK

AutoCAD SHX Text 3:8.5

AutoCAD SHX Text

EMERGENCY GENERATOR

AutoCAD SHX Text

FIRE PUMP ROOM

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

1. REFER TO GENERAL NOTES FOR THIS DISCIPLINE. REFER TO GENERAL NOTES FOR THIS DISCIPLINE. 2. REFER TO AND COMPLY WITH SPECIFICATIONS. REFER TO AND COMPLY WITH SPECIFICATIONS. 3. THIS PLAN IS INTENDED TO GIVE THE CONTRACTOR A GENERAL THIS PLAN IS INTENDED TO GIVE THE CONTRACTOR A GENERAL IDEA OF THE LOCATION OF EXISTING ELECTRICAL PANELS AND EQUIPMENT FED FROM THE SWITCHBOARD BEING REPLACED, AND TO INDICATE WHETHER ANY FEEDERS ARE TO BE REMOVED AND REPLACED IN THEIR ENTIRETY. REFER TO RISER FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

AutoCAD SHX Text 1/32"=1'-0"

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

64'

ELECTRICAL PLAN - DEMOLITION

Drawing No.

Drawing Title:

Designed By:

Drawn By:

Checked By:

Issue Date:

Drawing Scale:

Key Plan

Revisions No.

100% CD SUBMITTAL

05-13-2025

OCEAN CENTER

ELECTRICAL

SWITCHGEAR

REPLACEMENT

MPE PROJ#: 2024-040

THIS DRAWING IS THE PROPERTY OF MATERN PROFESSIONAL

ENGINEERING, INC. UNLESS OTHERWISE PROVIDED BY THE

CONTRACT, THE CONTENTS OF THIS DRAWING SHALL NOT BE

TRANSMITTED TO ANY OTHER PARTY EXCEPT AS AGREED TO

BY THE ENGINEER.

FAX (407) 740-0365

PHONE (407) 740-5020

CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096

130 Candace Drive Maitland, FL 32751

Date Description

101 N ATLANTIC AVE.

DAYTONA BEACH, FL 32118

APP

APP

BP

1/4" - 1'-0"

ELECTRICAL PLAN -

DEMOLITION

ED101

AutoCAD SHX Text

ELECTRICAL ROOM

AutoCAD SHX Text

BUILDING MAINTENANCE

AutoCAD SHX Text

TRANSFORMER VAULT

AutoCAD SHX Text

EMERGENCY GENERATOR

AutoCAD SHX Text EXISTING SWITCHBOARD AND BUSWAYS TO BE DEMOLISHED. REFER TO PARTIAL RISER DIAGRAMS ON SHEET E500 FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

1) PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS PRIOR TO SUBMITTING BID, VISIT SITE AND IDENTIFY EXISTING CONDITIONS AND DIFFICULTIES THAT WILL AFFECT THE DEMOLITION WORK. THIS CONTRACTOR SHALL PARTICIPATE IN THE SURVEY OF EXISTING ELECTRICAL SERVICES. 2) ELECTRICAL CONTRACTOR SHALL DISCONNECT AND CAP ALL ELECTRICAL ELECTRICAL CONTRACTOR SHALL DISCONNECT AND CAP ALL ELECTRICAL SERVICES WITHIN THE DEMOLITION AREA. PARTICULAR CARE SHALL BE TAKEN TO AVOID CREATING HAZARD OR CAUSING DISRUPTION OF SERVICES IN ADJOINING AREAS. ANY SUCH AREAS IN QUESTION AND NOT SHOWN ON DRAWING SHALL BE INVESTIGATED PRIOR TO REMOVAL. 3) IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO PROTECT IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO PROTECT AND MAINTAIN THE INTEGRITY OF REMAINING DEVICES OR EQUIPMENT. CONNECTIONS SHALL BE CONCEALED UNLESS LOCATED IN UNFINISHED AREA. 4) IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO PROPERLY IT SHALL BE THE ELECTRICAL CONTRACTORS RESPONSIBILITY TO PROPERLY SUPPORT EXISTING CONDUIT AND LABEL JUNCTION BOXES, ETC. PASSING THROUGH RENOVATED AREAS. 5) PORTIONS OF THE EXISTING BUILDING ARE TO REMAIN IN OPERATION PORTIONS OF THE EXISTING BUILDING ARE TO REMAIN IN OPERATION DURING CONSTRUCTION. ELECTRICAL CONTRACTOR SHALL COORDINATE ALL WORK THAT WILL INTERFERE WITH THE OPERATION OF THE FACILITY, WITH THE OWNER'S REPRESENTATIVE AND CONSTRUCTION MANAGER. ELECTRICAL CONTRACTOR SHALL PROVIDE TEMPORARY POWER TO ALL EQUIPMENT THAT MUST REMAIN IN OPERATION. 6) DURING THE DEMOLITION AND ALTERATION, THE FIRE ALARM SYSTEM SHALL DURING THE DEMOLITION AND ALTERATION, THE FIRE ALARM SYSTEM SHALL REMAIN IN OPERATION. 7) THE CONTRACTOR SHALL NOT ABANDON FEEDER OR BRANCH CIRCUIT THE CONTRACTOR SHALL NOT ABANDON FEEDER OR BRANCH CIRCUIT WIRING IN EXISTING WALLS AND CEILINGS. CONTRACTOR SHALL FIELD VERIFY ALL FEEDERS AND MAINTAIN THE CONTINUITY OF THE FEEDERS AND BRANCH CIRCUIT WIRING TO ALL AREAS WHICH ARE TO REMAIN BUT THAT ARE AFFECTED BY THE DEMOLITION OR NEW CONSTRUCTION. 8) CONTRACTOR SHALL INCLUDE IN HIS BID THE TRANSPORT AND DISPOSAL CONTRACTOR SHALL INCLUDE IN HIS BID THE TRANSPORT AND DISPOSAL OR RECYCLING OF ALL WASTE MATERIALS GENERATED BY THE THIS PROJECT IN ACCORDANCE WITH ALL RULES, REGULATIONS AND GUIDELINES APPLICABLE AT TIME OF DISPOSAL. CONTRACTOR SHALL PROVIDE OWNER WITH WRITTEN CERTIFICATION OF ACCEPTED DISPOSAL.

AutoCAD SHX Text

%%UHEX NOTES

AutoCAD SHX Text

AutoCAD SHX Text 1/4" =1'-0"

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text

T1E-EXA1 (SUSPENDED)

AutoCAD SHX Text

ATS P3E-EXA1

AutoCAD SHX Text

P3E-EXA1

AutoCAD SHX Text

L3E-EXA1

AutoCAD SHX Text

R1E-EXA1

AutoCAD SHX Text

R1N-EXA1

AutoCAD SHX Text

L3N-EXD1

AutoCAD SHX Text

EXISTING SHOW POWER DISC 1200 AMP

AutoCAD SHX Text

EXISTING SHOW POWER DISC 1200 AMP CB

AutoCAD SHX Text

EXISTING 18" VERTICAL WIREWAY

AutoCAD SHX Text

DIST. NO BREAKERS

AutoCAD SHX Text

DIST.

AutoCAD SHX Text

S1N-EXA1 MAIN

AutoCAD SHX Text

T1N-EXA1 500KVA XFMR

AutoCAD SHX Text

S3-EXA1 METER MAIN

AutoCAD SHX Text 1-T1E

AutoCAD SHX Text

S3N-EXA2 METER MAIN

AutoCAD SHX Text

EXISTING HOUSEKEEPING PAD

AutoCAD SHX Text EXISTING WIREWAY, 12"D x 18" TALL

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text

AutoCAD SHX Text

DIST.

AutoCAD SHX Text

DIST.

AutoCAD SHX Text

DIST.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

M4N-EXA1

BLDG. MAINT.

ELECTRICAL PLAN - RENOVATION

I I DTIEDDDD NP

Drawing No.

Drawing Title:

Designed By:

Drawn By:

Checked By:

Issue Date:

Drawing Scale:

Key Plan

Revisions No.

100% CD SUBMITTAL

05-13-2025

OCEAN CENTER

ELECTRICAL

SWITCHGEAR

REPLACEMENT

MPE PROJ#: 2024-040

THIS DRAWING IS THE PROPERTY OF MATERN PROFESSIONAL

ENGINEERING, INC. UNLESS OTHERWISE PROVIDED BY THE

CONTRACT, THE CONTENTS OF THIS DRAWING SHALL NOT BE

TRANSMITTED TO ANY OTHER PARTY EXCEPT AS AGREED TO

BY THE ENGINEER.

FAX (407) 740-0365

PHONE (407) 740-5020

CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096

130 Candace Drive Maitland, FL 32751

Date Description

101 N ATLANTIC AVE.

DAYTONA BEACH, FL 32118

APP/BP

APP

BP

1/4" - 1'-0"

ELECTRICAL PLAN -

RENOVATION

E101

AutoCAD SHX Text

ELECTRICAL ROOM

AutoCAD SHX Text

BUILDING MAINTENANCE

AutoCAD SHX Text

TRANSFORMER VAULT

AutoCAD SHX Text

EMERGENCY GENERATOR

AutoCAD SHX Text NEW SWITCHBOARD 'MSB' SHALL BE INSTALLED ON EXISTING CONCRETE PAD. EXISTING CONCRETE PAD SHALL BE MODIFIED AND SHAVED BACK TO EXTEND 6" FROM EACH SIDE OF SWITCHBOARD. COORDINATE PLACEMENT OF NEW SWITCHBOARD WITH ALL EXISTING UNDERGROUND FEEDERS. EXTEND CONDUCTORS AS REQUIRED TO ACCOMMODATE NEW LAYOUT. IF SPLICING IS NECESSARY, ALL SPLICES SHALL BE MADE ABOVE GRADE AND WITHIN SWITCHBOARD ENCLOSURE. SPLICING OF CABLES IN GROUND OR BELOW FINISHED GRADE IS NOT PERMITTED. ALL SPLICES SHALL BE MADE USING COMPRESSION-TYPE CONNECTORS AND COVERED WITH RAYCHEM HEAVYWALL CABLE SLEEVES. CONTRACTOR SHALL INCLUDE AN ITEMIZED BUDGET FOR EACH SPLICE IN THEIR PROPOSAL, INCLUDING MATERIALS AND LABOR. REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE NEW 480Y/277V, 3-PHASE, 4-WIRE, 2000A COPPER BUSWAY MANUFACTURER: SQUARE D; MODEL I-LINE II BUSWAY, WITH ALL REQUIRED COMPONENTS FOR CONNECTION TO NEW SWITCHBOARD. COORDINATE WITH THE UTILITY AND OTHER EXISTING ELECTRICAL SYSTEMS TO UTILIZE THE EXISTING WALL PENETRATION. SUBMIT FINAL SHOP DRAWINGS TO THE ENGINEER OF RECORD (EOR) FOR APPROVAL PRIOR TO PROCUREMENT.

AutoCAD SHX Text

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

1. REFER TO PROJECT GENERAL NOTES, LEGEND, SCHEDULE ON SHEET E001. REFER TO PROJECT GENERAL NOTES, LEGEND, SCHEDULE ON SHEET E001. 2. REFER TO AND COMPLY WITH SPECIFICATIONS. REFER TO AND COMPLY WITH SPECIFICATIONS. 3. REFER TO PARTIAL RISER DIAGRAM ON SHEET E500 FOR ADDITIONAL REFER TO PARTIAL RISER DIAGRAM ON SHEET E500 FOR ADDITIONAL INFORMATION.

AutoCAD SHX Text

%%UHEX NOTES

AutoCAD SHX Text

AutoCAD SHX Text 1/4" =1'-0"

AutoCAD SHX Text 2'

AutoCAD SHX Text 4'

AutoCAD SHX Text 8'

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text

T1E-EXA1 (SUSPENDED)

AutoCAD SHX Text

ATS P3E-EXA1

AutoCAD SHX Text

P3E-EXA1

AutoCAD SHX Text

L3E-EXA1

AutoCAD SHX Text

R1E-EXA1

AutoCAD SHX Text

R1N-EXA1

AutoCAD SHX Text

EXISTING HOUSEKEEPING PAD

AutoCAD SHX Text

SS 2

AutoCAD SHX Text

SS 3

AutoCAD SHX Text

XFMR

AutoCAD SHX Text

SS 1

AutoCAD SHX Text

SS 2

AutoCAD SHX Text

SS 3

AutoCAD SHX Text

SS 4

AutoCAD SHX Text

SS 5

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

MSB

AutoCAD SHX Text

AutoCAD SHX Text

L3N-EXD1

AutoCAD SHX Text

EXISTING SHOW POWER DISC 1200 AMP

AutoCAD SHX Text

EXISTING SHOW POWER DISC 1200 AMP CB

AutoCAD SHX Text

EXISTING 18" VERTICAL WIREWAY

AutoCAD SHX Text EXISTING WIREWAY, 12"D x 18" TALL

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

M4N-EXA1

AutoCAD SHX Text

BLDG. MAINT.

PARTIAL RISER DIAGRAM - RENOVATION

PARTIAL RISER DIAGRAM - DEMOLITION

Drawing No.

Drawing Title:

Designed By:

Drawn By:

Checked By:

Issue Date:

Drawing Scale:

Key Plan

Revisions No.

100% CD SUBMITTAL

05-13-2025

OCEAN CENTER

ELECTRICAL

SWITCHGEAR

REPLACEMENT

MPE PROJ#: 2024-040

THIS DRAWING IS THE PROPERTY OF MATERN PROFESSIONAL

ENGINEERING, INC. UNLESS OTHERWISE PROVIDED BY THE

CONTRACT, THE CONTENTS OF THIS DRAWING SHALL NOT BE

TRANSMITTED TO ANY OTHER PARTY EXCEPT AS AGREED TO

BY THE ENGINEER.

FAX (407) 740-0365

PHONE (407) 740-5020

CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096

130 Candace Drive Maitland, FL 32751

Date Description

101 N ATLANTIC AVE.

DAYTONA BEACH, FL 32118

APP

APP

BP

NTS

PARTIAL RISER

DIAGRAM

ELECTRICAL

E500

AutoCAD SHX Text

R1N-EXA1

AutoCAD SHX Text

EXHIBIT LEVEL

AutoCAD SHX Text

MEZZANINE LEVEL

AutoCAD SHX Text

CATWALK LEVEL

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text

ATS A3E-EXA1 (P3E)

AutoCAD SHX Text

L3N-EXD1

AutoCAD SHX Text

R1N-EXD1

AutoCAD SHX Text

P1N-EXD1

AutoCAD SHX Text

R1N-EXA2

AutoCAD SHX Text

P3N-EXB1

AutoCAD SHX Text

T1N-MZB1

AutoCAD SHX Text G

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text

M4N-MZA1

AutoCAD SHX Text

R1N-MZA3

AutoCAD SHX Text

R1N-MZA1

AutoCAD SHX Text

M4N-MZD1

AutoCAD SHX Text

R/D-MZD1

AutoCAD SHX Text

R1N-MZD1

AutoCAD SHX Text

R1N-MZD2

AutoCAD SHX Text

P1N-EXA1

AutoCAD SHX Text

R1N-EXA3

AutoCAD SHX Text

M4N-EXA1

AutoCAD SHX Text

CW-1 (WIREWAY)

AutoCAD SHX Text

CW-2 (WIREWAY)

AutoCAD SHX Text

CW-5 (WIREWAY)

AutoCAD SHX Text

CW-4 (WIREWAY)

AutoCAD SHX Text

MSB

AutoCAD SHX Text

EX-5 (WIREWAY)

AutoCAD SHX Text

M4N-EXD1

AutoCAD SHX Text

T1N-MZB1

AutoCAD SHX Text

M4N-MZA1

AutoCAD SHX Text

R1N-MZA3

AutoCAD SHX Text

R1N-MZA1

AutoCAD SHX Text

M4N-MZD1

AutoCAD SHX Text

R/D-MZD1

AutoCAD SHX Text

R1N-MZD1

AutoCAD SHX Text

R1N-MZD2

AutoCAD SHX Text

CW-1 (WIREWAY)

AutoCAD SHX Text

CW-2 (WIREWAY)

AutoCAD SHX Text

CW-5 (WIREWAY)

AutoCAD SHX Text

CW-4 (WIREWAY)

AutoCAD SHX Text

R1N-EXA1

AutoCAD SHX Text

ATS A3E-EXA1 (P3E)

AutoCAD SHX Text

L3N-EXD1

AutoCAD SHX Text

R1N-EXD1

AutoCAD SHX Text

P1N-EXD1

AutoCAD SHX Text

R1N-EXA2

AutoCAD SHX Text

P3N-EXB1

AutoCAD SHX Text

P1N-EXA1

AutoCAD SHX Text

R1N-EXA3

AutoCAD SHX Text

M4N-EXA1

AutoCAD SHX Text

EX-5 (WIREWAY)

AutoCAD SHX Text

M4N-EXD1

AutoCAD SHX Text 3#400, 1#3G

AutoCAD SHX Text 3#4/0, 1#2G

AutoCAD SHX Text

400A FRAME / 350A TRIP

AutoCAD SHX Text

600A FRAME / 450A TRIP

AutoCAD SHX Text 3#3/0, 1#6G

AutoCAD SHX Text

225A FRAME / 200A TRIP

AutoCAD SHX Text 3#3/0, 1#6G

AutoCAD SHX Text

225A FRAME / 200A TRIP

AutoCAD SHX Text 3#300, 1#300N, 1#1G

AutoCAD SHX Text

600A FRAME / 600A TRIP

AutoCAD SHX Text 3#8, 1#8N, 1#10G

AutoCAD SHX Text

100A FRAME / 50A TRIP

AutoCAD SHX Text

FEEDER DESIGNATION (COPPER CONDUCTORS) (PER SET)

AutoCAD SHX Text

AutoCAD SHX Text

CONDUIT SIZE (PER SET)

AutoCAD SHX Text

AutoCAD SHX Text 2"

AutoCAD SHX Text 3"

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text 2"

AutoCAD SHX Text

AutoCAD SHX Text 2"

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text

AutoCAD SHX Text

NUMBER OF SETS

AutoCAD SHX Text

PANEL/LOAD DESIGNATION

AutoCAD SHX Text 3#1/0, 1#6G

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text

225A FRAME / 150A TRIP

AutoCAD SHX Text 3#300, 1#4G

AutoCAD SHX Text

400A FRAME / 300A TRIP

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text

AutoCAD SHX Text 3#1, 1#1N, 1#6G

AutoCAD SHX Text

225A FRAME / 125A TRIP

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text 3#400, 1#400N, 1#2/0G

AutoCAD SHX Text

1000A FRAME /1000A TRIP

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text 3#2, 1#6G

AutoCAD SHX Text

100A FRAME / 100A TRIP

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text 3#6, 1#6N, 1#10G

AutoCAD SHX Text

100A FRAME / 60A TRIP

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text 3#2, 1#2N, 1#6G

AutoCAD SHX Text

100A FRAME / 100A TRIP

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text 3#1, 1#1N, 1#6G

AutoCAD SHX Text

225A FRAME / 125A TRIP

AutoCAD SHX Text 1-1/2"

AutoCAD SHX Text

AutoCAD SHX Text 3#1/0, 1#1/0N, 1#6G

AutoCAD SHX Text 2"

AutoCAD SHX Text

AutoCAD SHX Text

225A FRAME / 150A TRIP

AutoCAD SHX Text

BRANCH DEVICE

AutoCAD SHX Text 3#400, 1#400N, 1#2/0G

AutoCAD SHX Text

1000A FRAME /1000A TRIP

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text 3#4, 1#4N, 1#8G

AutoCAD SHX Text

100A FRAME / 70A TRIP

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text 3#6, 1#6N, 1#8G

AutoCAD SHX Text

100A FRAME / 60A TRIP

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text 3#6, 1#6N, 1#10G

AutoCAD SHX Text

100A FRAME / 60A TRIP

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text 3#4, 1#4N, 1#8G

AutoCAD SHX Text

100A FRAME / 60A TRIP

AutoCAD SHX Text 1-1/4"

AutoCAD SHX Text

AutoCAD SHX Text 3#6, 1#6N, 1#10G

AutoCAD SHX Text

100A FRAME / 70A TRIP

AutoCAD SHX Text 1"

AutoCAD SHX Text

AutoCAD SHX Text 3#400, 1#400N, 1#2/0G

AutoCAD SHX Text

1000A FRAME /1000A TRIP

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text

400A FRAME / 300A TRIP

AutoCAD SHX Text

600A FRAME / 500A TRIP

AutoCAD SHX Text

EX-6 (WIREWAY)

AutoCAD SHX Text

600A FRAME / 600A TRIP

AutoCAD SHX Text

CHILLER 1

AutoCAD SHX Text

600A FRAME / 400A TRIP

AutoCAD SHX Text

CHILLER 2

AutoCAD SHX Text

1000A FRAME / 900A TRIP

AutoCAD SHX Text 3#500, 1#3G

AutoCAD SHX Text

AutoCAD SHX Text 3"

AutoCAD SHX Text 3#300, 1#1/0G

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text

AutoCAD SHX Text 3#4/0, 1#4/0N, 1#2G

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text

AutoCAD SHX Text 3#350, 1#1G

AutoCAD SHX Text

AutoCAD SHX Text 2-1/2"

AutoCAD SHX Text 3#500, 3#500N, 1#3G

AutoCAD SHX Text

AutoCAD SHX Text 3-1/2"

AutoCAD SHX Text THE INFORMATION SHOWN ON THE SCHEDULE IS FOR REFERENCE ONLY, HAS BEEN TAKEN FROM AS-BUILT DRAWINGS, AND HAS NOT BEEN VERIFIED.

AutoCAD SHX Text

R1N-EXA1

AutoCAD SHX Text

EXHIBIT LEVEL

AutoCAD SHX Text

MEZZANINE LEVEL

AutoCAD SHX Text

CATWALK LEVEL

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text L

AutoCAD SHX Text

ATS A3E-EXA1 (P3E)

AutoCAD SHX Text

L3N-EXD1

AutoCAD SHX Text

R1N-EXD1

AutoCAD SHX Text

P1N-EXD1

AutoCAD SHX Text

R1N-EXA2

AutoCAD SHX Text

P3N-EXB1

AutoCAD SHX Text

T1N-MZB1

AutoCAD SHX Text G

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text

M4N-MZA1

AutoCAD SHX Text

R1N-MZA3

AutoCAD SHX Text

R1N-MZA1

AutoCAD SHX Text

M4N-MZD1

AutoCAD SHX Text

R/D-MZD1

AutoCAD SHX Text

R1N-MZD1

AutoCAD SHX Text

R1N-MZD2

AutoCAD SHX Text

P1N-EXA1

AutoCAD SHX Text

R1N-EXA3

AutoCAD SHX Text

M4N-EXA1

AutoCAD SHX Text

CW-1 (WIREWAY)

AutoCAD SHX Text

CW-2 (WIREWAY)

AutoCAD SHX Text

CW-5 (WIREWAY)

AutoCAD SHX Text

CW-4 (WIREWAY)

AutoCAD SHX Text

MSB

AutoCAD SHX Text

EX-5 (WIREWAY)

AutoCAD SHX Text

M4N-EXD1

AutoCAD SHX Text PROVIDE A NEW SERVICE ENTRANCE-RATED SWITCHBOARD; MANUFACTURER: SQUARE D; MODEL: QED-2, 480Y/277V, 3-PHASE, 4-WIRE, SCCR: 65KA RMS, NEMA 1 ENCLOSURE. SWITCHBOARD SHALL INCLUDE TWO (2) INCOMING SECTIONS WITH BUSWAY ENTRY THROUGH THE TOP AND A MAIN-TIE-MAIN CONFIGURATION. EACH MAIN INCOMING SECTION SHALL BE EQUIPPED WITH A REMOTE MONITORING METER CAPABLE OF DETAILED POWER AND ENERGY METERING, POWER QUALITY MONITORING, AND UTILITY MANAGEMENT FUNCTIONS. REFER TO ELEVATION PLAN ON SHEET E600 FOR INFORMATION REGARDING CIRCUIT BREAKERS AND BREAKER SIZES. SURGE SUPPRESSOR. REFER TO SPECIFICATIONS. CONNECT EXISTING MAIN BUILDING SHUNT TRIP SYSTEM TO NEW MAIN BREAKER. PROVIDE NEW 480Y/277V, 3-PHASE, 4-WIRE, 2000A COPPER BUSWAY; MANUFACTURER: SQUARE D; MODEL: I-LINE II BUSWAY, WITH ALL REQUIRED COMPONENTS FOR CONNECTION TO NEW SWITCHBOARD. COORDINATE WITH THE UTILITY AND OTHER EXISTING ELECTRICAL SYSTEMS TO UTILIZE THE EXISTING WALL PENETRATION. SUBMIT FINAL SHOP DRAWINGS TO THE ENGINEER OF RECORD (EOR) FOR APPROVAL PRIOR TO PROCUREMENT. NEW SWITCHBOARD SHALL BE BONDED TO EXISTING GROUNDING SYSTEM IN ACCORDANCE WITH NEC ARTICLE 250 AND LOCAL CODE REQUIREMENTS. ANY DEFICIENCIES IN THE EXISTING GROUNDING SYSTEM THAT COULD IMPACT CODE COMPLIANCE OR SYSTEM PERFORMANCE SHALL BE REPORTED TO ENGINEER AND OWNER PRIOR TO CONNECTION. REFER TO THE "GROUNDING SYSTEM" DETAILS FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL COORDINATE WITH OWNER TO SCHEDULE AND OBTAIN APPROVAL FOR ANY REQUIRED ELECTRICAL SHUTDOWNS RELATED TO THE REPLACEMENT OF THE MAIN ELECTRICAL SWITCHBOARD. ADDITIONALLY, CONTRACTOR SHALL COORDINATE SHUTDOWN AND VAULT ACCESS WITH UTILITY COMPANY (FPL). A MINIMUM OF 30 DAYS ADVANCE WRITTEN NOTICE SHALL BE PROVIDED TO THE OWNER PRIOR TO ANY PLANNED OUTAGE. ALL SHUTDOWNS SHALL BE CONDUCTED DURING OWNER-APPROVED HOURS AND SHALL BE SCHEDULED TO MINIMIZE IMPACT TO OWNER OPERATIONS. CONTRACTOR SHALL PREPARE AND SUBMIT A DETAILED ELECTRICAL SHUTDOWN PLAN FOR REVIEW AND APPROVAL BY THE OWNER AND ENGINEER NO LESS THAN 30 DAYS PRIOR TO THE PROPOSED SHUTDOWN DATE. THE PLAN SHALL INCLUDE A SEQUENCE OF WORK, PROPOSED SHUTDOWN DURATION, TEMPORARY POWER PROVISIONS, SAFETY MEASURES, NOTIFICATION PROCEDURES, AND RESTORATION STEPS.

AutoCAD SHX Text

AutoCAD SHX Text

%%UGENERAL NOTES

AutoCAD SHX Text

1. REFER TO GENERAL NOTES FOR THIS DISCIPLINE. REFER TO GENERAL NOTES FOR THIS DISCIPLINE. 2. REFER TO AND COMPLY WITH SPECIFICATIONS. REFER TO AND COMPLY WITH SPECIFICATIONS. 3. ASSUMED SHORT CIRCUIT AMPS AVAIL: 60,000 - 85,000. TO BE VERIFIED WITH LOCAL POWER COMPANY. ASSUMED SHORT CIRCUIT AMPS AVAIL: 60,000 - 85,000. TO BE VERIFIED WITH LOCAL POWER COMPANY. 4. WHERE AVAILABLE SHORT CIRCUIT/FAULT AMPS FROM POWER COMPANY TRANSFORMER IS HIGHER THEN THAT WHERE AVAILABLE SHORT CIRCUIT/FAULT AMPS FROM POWER COMPANY TRANSFORMER IS HIGHER THEN THAT ASSUMED ABOVE, REVISE RATINGS OF ALL ELECTRICAL EQUIPMENT INCLUDING BUT NOT LIMITED TO PANELS, DISTRIBUTION PANELS, SWITCHBOARDS, DISCONNECT SWITCHES, ETC. AS REQUIRED TO COORDINATE WITH AVAILABLE AMPS. 5. ALL ELECTRICAL EQUIPMENT AS DEFINED BY NEC 110.16 SHALL BE PROVIDED WITH ARC-FLASH WARNING ALL ELECTRICAL EQUIPMENT AS DEFINED BY NEC 110.16 SHALL BE PROVIDED WITH ARC-FLASH WARNING STICKER. REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS. 6. ALL ELECTRICAL EQUIPMENT SHALL BE IDENTIFIED WITH EQUIPMENT IDENTIFICATION NAME PLATE AND VOLTAGE ALL ELECTRICAL EQUIPMENT SHALL BE IDENTIFIED WITH EQUIPMENT IDENTIFICATION NAME PLATE AND VOLTAGE SYSTEM COLOR CODE PLACARD. REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL EQUIPMENT. 7. MAIN SERVICE EQUIPMENT SHALL BE PROVIDED WITH FIELD MARKING INDICATING MAXIMUM AVAILABLE FAULT MAIN SERVICE EQUIPMENT SHALL BE PROVIDED WITH FIELD MARKING INDICATING MAXIMUM AVAILABLE FAULT CURRENT IN ACCORDANCE WITH NEC 110.24. REFER TO SPECIFICATIONS AND DETAILS FOR ADDITIONAL REQUIREMENTS.

AutoCAD SHX Text

%%UHEX NOTES - RENOVATION:

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

EX-6 (WIREWAY)

AutoCAD SHX Text

EX-6 (WIREWAY)

AutoCAD SHX Text

AutoCAD SHX Text D1

AutoCAD SHX Text

%%UHEX NOTES - DEMOLITION:

AutoCAD SHX Text D1

AutoCAD SHX Text

SPD

AutoCAD SHX Text

SPD

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D2

AutoCAD SHX Text D2

AutoCAD SHX Text EXISTING SWITCHBOARD TO BE DEMOLISHED. ALL EXISTING FEEDERS SHALL BE MEGGER TESTED TO ENSURE GOOD WORKING CONDITIONS. IF DEEMED IN GOOD WORKING CONDITION, PROTECT AND PREPARE FOR CONNECTION TO NEW SWITCH GEAR. IF NOT, EXISTING FEEDERS SHALL BE REPLACED, MATCHING EXISTING CONDITIONS. EXISTING BUSWAY TO BE DEMOLISHED. COORDINATE AND PREPARE WITH OWNER AND UTILITY COMPANY FOR NEW BUSWAY TO BE INSTALLED AND CONNECTED TO NEW SWITCHBOARD, INCLUDING ANY STRUCTURAL AND/OR WALL PENETRATIONS. EXISTING BUILDING GROUNDING SYSTEM SHALL BE TESTED AND DOCUMENTED IN ACCORDANCE WITH SPECIFICATIONS, AND BE PREPARED FOR CONNECTION TO NEW SWITCHBOARD.

AutoCAD SHX Text D2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text D3

AutoCAD SHX Text D3

AutoCAD SHX Text

AutoCAD SHX Text

EXISTING SWITCHBOARD ELEVATION

NEW SWITCHBOARD ELEVATION Drawing No.

Drawing Title:

Designed By:

Drawn By:

Checked By:

Issue Date:

Drawing Scale:

Key Plan

Revisions No.

100% CD SUBMITTAL

05-13-2025

OCEAN CENTER

ELECTRICAL

SWITCHGEAR

REPLACEMENT

MPE PROJ#: 2024-040

THIS DRAWING IS THE PROPERTY OF MATERN PROFESSIONAL

ENGINEERING, INC. UNLESS OTHERWISE PROVIDED BY THE

CONTRACT, THE CONTENTS OF THIS DRAWING SHALL NOT BE

TRANSMITTED TO ANY OTHER PARTY EXCEPT AS AGREED TO

BY THE ENGINEER.

FAX (407) 740-0365

PHONE (407) 740-5020

CERT. OF AUTH. No. 5096 ENG. BUS. No. EB-0005096

130 Candace Drive Maitland, FL 32751

Date Description

101 N ATLANTIC AVE.

DAYTONA BEACH, FL 32118

APP/BP

APP

BP

NTS

ELEVATIONS

ELECTRICAL

E600

AutoCAD SHX Text

(L3N-EXD1)

AutoCAD SHX Text

(S3N-EXA1)

AutoCAD SHX Text

(S3N-EXA2)

AutoCAD SHX Text

(DIST.)

AutoCAD SHX Text

(1-TIE)

AutoCAD SHX Text 100/3

AutoCAD SHX Text 125/3

AutoCAD SHX Text 300/3

Auto…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .