This solicitation is for road construction and repair projects across three sites within the Great Smoky Mountains National Park. The projects include full depth reclamation and asphalt paving of 6.41 miles of Lakeview Drive East in Swain County, North Carolina. In Sevier County, Tennessee, the scope involves asphalt milling and overlay of 3.05 miles of roads, and reconstructing 0.97 miles of additional roads. The third site in Swain County includes placing a thin lift of asphalt on 6.13 miles of roads. Associated work at all sites involves patching, stonework, guardrails, drainage, and signs. The total cost of all projects is estimated between $25-35 million. Proposals from certified Small Business Concerns are due in February 2023, with the specific date and location provided in the solicitation. Experience on projects of similar complexity and magnitude is required.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CULVERT INSPECTION REPORT

TWO MILE BRANCH CULVERT

NEWFOUND GAP ROAD OVER TWO MILE BRANCH

GREAT SMOKY MOUNTAINS NATIONAL PARK

LN

STRUCTURE NO. 5460-211P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 5/12/2022

EU

Report prepared by:

Federal Highway Administration Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov

STRUCTURE SUMMARY STRUCTURE NO. 5460-211P

TWO MILE BRANCH CULVERT INSPECTION DATE: 05/12/2022

CULVERT IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ..... 1 - CONCRETE NO. OF BARRELS:

FOUNDATION: .................... 2 - SPREAD FTG ON BEARING BARREL LENGTH: ............. 48 FT (14.63 M)

STRUCT. TOTAL LENGTH: 20.0 FT (6.1 M) SKEW ANGLE: ................... 0 °

MAX. SPAN LENGTH: ........ 9.0 FT (2.7 M) YEAR BUILT:

PROJ./PLAN REF. NO: ....... YEAR RECONSTRUCTED: 1937

NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD

STRUCTURE HISTORY: .... 2012-ROADWAY REPAVED.

LOCATION

GREAT SMOKY MOUNTAINS NATIONAL PARK MILE POINT: .. 1.10 (KM PT 1.77)

STATE: ................................ 474 - TENNESSEE LOCATION: .... JUST NORTH OF ENTRANCE TO

SUGARLAND RIDING STABLES, JUSTFACILITY CARRIED: .......... NEWFOUND GAP ROAD

SOUTH OF GATLINBURG.

FEATURE INTERSECTED: TWO MILE BRANCH

INSPECTION TEAM: O. Tariq, J. Valcheff

CONDITION ASSESSMENT:

Osama Tariq

REPORT REVIEW:

Zane Bailey 703-404-6242

REPORT APPROVAL: Date: 10/27/2022

Jorgomai Ceesay

STRUCTURE EVALUATION SUMMARY

This two-barrel culvert remains in poor condition. The main problem is site-related scour and undermining of the masonry wall footings with the most severe case of scour at the intermediate wall, where an 8' long void with full width undermining is permitting water to flow from the south barrel into the north barrel. In addition, the concrete footing is exposed throughout.

Other problems include deterioration of the masonry footings, debris and rock accumulation in the barrels, spalling with section loss on exposed rebar on the barrel ceiling, heavy vegetation growth adjacent to and on the west wingwalls, accumulation of drift at the upstream side, and pothole on the south approach pavement in the southbound lanes.

Corrective measures should be taken as outlined in this report to help prevent the possible development of more serious or costly problems in the future.

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5460-211P

TWO MILE BRANCH CULVERT INSPECTION DATE : 05/12/2022

226 PRIORITY OF IMPROVEMENT B

A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

Item No.

Maintenance Recommendations

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT UNIT

COST

PRELIM.

COST

ESTIMATE

60.6 REMOVE VEGETATION ADJACENT TO AND ON WEST

WINGWALLS. 1 LS 3000 3000

222.7 INSTALL REFLECTIVE OBJECT MARKERS AT HEADWALLS.

4 EA 250 1000

222.4 PATCH ASPHALT PAVEMENT AT SOUTH APPROACH IN

SOUTHBOUND LANES. 1 LS 500 500

PRELIM. MAINTENANCE TOTAL : 4500

Item No.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST

PRELIM. COST ESTIMATES

REHAB RECONSTR

36.C,36.

D

INSTALL GUARDRAIL SYSTEM OVER

STRUCTURE AND AT APPROACHES. 1 LS 60000 60000

61.2,62.2, 62.6

REPAIR SCOUR, UNDERMINING, AND

DETERIORATION OF FOOTINGS THROUGHOUT

STRUCTURE.

1 LS 20000 20000

61.4,62.5 REMOVE EMBANKMENT SOIL, DEBRIS, AND

ROCK ACCUMULATION FROM UPSTREAM SIDE

AND WITHIN BARRELS.

1 LS 5000 5000

62.1 CLEAN EXPOSED REBAR ON BARRELS AND

COAT WITH APPROVED SEALANT. 1 LS 2000 2000

CONTRACT COSTS FOR MOBILIZATION,

TRAFFIC CONTROL, AND CONTINGENCIES. 1 LS 43000 43000

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : 130000

1 LS 3000 3000

4 EA 250 1000

1 LS 500 500

1 LS 60000 60000

1 LS 20000 20000

1 LS 5000 5000

1 LS 2000 2000

1 LS 43000 43000

130000

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5460-211P

TWO MILE BRANCH CULVERT INSPECTION DATE : 05/12/2022

226 PRIORITY OF IMPROVEMENT B

A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL :

PRELIM. REHABILITATION TOTAL :

PRELIM. RECONSTRUCTION TOTAL : .. 0

134500TOTAL ITEMIZED COSTS:

PRELIMINARY ESTIMATE TOTAL * :

(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)

Remarks : Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

1345004500

130000130000130000

134500

STRUCTURE NO. 5460-211P

TWO MILE BRANCH CULVERT INSPECTION DATE: 05/11/2022

N NOT APPLICABLE 3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible. Fatigue cracks in steel or

9 EXCELLENT CONDITION shear cracks in concrete may be present.

8 VERY GOOD CONDITION - no problems noted. 2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed

7 GOOD CONDITION - some minor problems. substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

6 SATISFACTORY CONDITION - structural elements show some minor deterioration.

1 IMM NENT FAILURE CONDITION - major deterioration or section loss present in critical

5 FA R CONDITION - all primary structural elements are sound but may have minor structural components or obvious vertical or horizontal movement affecting structure stability.

section loss, cracking, spalling, or scour. Structure is closed to

4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour. 0 FA LED CONDITION - out of service; beyond corrective action.

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

6 7

1. ALIGNMENT: F 1. APPROACH SLABS: N

2. EROSION AND/OR SCOUR: F 2. RELIEF JOINTS: N

3. CHANNEL PROTECTION: N 3. APPROACH GUARDRAIL: N

4. WATERWAY OBSTRUCTIONS: P 4. SURFACING: G

5. OTHER: N 5. EROSION: G

6. ADEQUACY OF OPENING: 1- SUFF 6. SETTLEMENT: G

7. NORMAL VELOCITY: 2 - MED 7. SIGNS: N

8. AVERAGE CLEAR OPENING: 8 FT 8. ALIGNMENT: G

9. STREAM BED COMPOSITION: 9. OTHER: N

STONES, ROCK, GRAVEL N

1. BARREL(S): F

2. FOOTINGS: P

3. HEADWALLS: G

4. WINGWALLS: G

5. DEBRIS AND/OR SLIT: F

6. EROSION AND/OR SCOUR: P

7. SETTLEMENT AND/OR DEFLECTION: G

8. ADEQUACY OF COVER: G

9. PARAPETS AND/OR RAILINGS: N

10. ROADWAY SURFACE: G

11. RIDEABILITY: G

12. OTHER: VEGETATION F

1. WALL:

2. WEEP HOLES:

3. FOUNDATION:

4. EROSION AND/OR SCOUR:

5. SETTLEMENT OR DEFLECTION:

6. OTHER

A. BRIDGE RAILINGS: N

B. TRANSITIONS: N

C. APPROACH GUARDRAILS: 0

D. APPROACH GUARDRAIL ENDS: 0

0 - Does not meet standards or a safety features is required and none is provided.

1 - Meets currently acceptable standards.

N - Not applicable or a safety features is not required.

(cont'd) STRUCTURE NO. 5460-211P

61.1

61.4

61.6

62.5

SOIL AND ROCK EMBANKMENT EXTENDS INTO CHANNEL AT UPSTREAM END OF BOTH BARRELS AND DOWNSTREAM END OF SOUTH BARREL PARTIALLY RESTRICTING SOUTH BARREL AND MODERATELY RESTRICTING NORTH BARREL. MODERATE DRIFT, DEBRIS, AND ROCK ACCUMULATION IN BARRELS. MINOR DEBRIS ACCUMULATION AGAINST UPSTREAM END OF CENTER WALL.

61.2 SEE STRUCTURE FILE FOR SCOUR EVALUATION.

61.2

62.2

62.6

CULVERT CONTAINS CONCRETE CEILING SLAB, MASONRY WALLS, AND MASONRY FOOTINGS. MASONRY FOOTINGS 2"-10" THICK.

CULVERT EXTENSION AT WEST END CONSTRUCTED WITH CONCRETE CEILING SLAB, WALLS, AND FOOTINGS. MODERATE TO SEVERE DETERIORATION OF MASONRY FOOTINGS THROUGHOUT. MINOR SCALING OF CONCRETE FOOTINGS.

NORTH ENDWALL:

CONCRETE FOOTING EXPOSED (FULL LENGTH X UP TO 2'H) AT DOWNSTREAM END. SCOUR WITH UNDERMINING OF MASONRY FOOTING (1-1/2'H X UP TO 1.8' UNDER). MODERATE VOID UNDERNEATH MASONRY FOOTING (5'L X 1-1/2'H X 3' UNDER) WITH

EXPOSED REBAR NEAR MID-LENGTH AND AT EAST END.

INTERMEDIATE WALL:

MINOR SPALLING OF CONCRETE FOOTING AT DOWNSTREAM END OF SOUTH BARREL. CONCRETE FOOTING EXPOSED (FULL LENGTH X UP TO 2-1/2'H) ALONG BOTH SIDES OF WALL AT DOWNSTREAM END. SCOUR WITH UNDERMINING OF MASONRY FOOTING (1-1/2'H X UP TO 1-1/2' UNDER). MODERATE VOID UNDERNEATH MASONRY FOOTING (8'L X 1-1/2'H X FULL WIDTH UNDER)

NEAR MID-LENGTH WITH WATER FLOWING UNDER WALL FROM SOUTH BARREL TO NORTH BARREL.

SOUTH ENDWALL:

CONCRETE FOOTING EXPOSED (FULL LENGTH X UP TO 1.6'H) NEAR MID-LENGTH. SCOUR WITH UNDERMINING OF MASONRY

FOOTING (1.1'H X 1' UNDER) NEAR EAST END.

62.1 HEAVY EFFLORESCENCE BETWEEN BARREL CEILING AND MASONRY FASCIA. MODERATE TRANSVERSE CRACKING WITH MODERATE TO HEAVY EFFLORESCENCE AND RUST STAINING ON BARREL CEILING LOCATED WHERE INTERMEDIATE WALL IS UNDERMINED FOR FULL WIDTH; MINOR CRACKING ELSEWHERE. ADDITIONAL CONCRETE POURED ALONG CENTER WALL IN

SOUTH BARREL AT MID-LENGTH OF CULVERT.

MINOR DETERIORATION OF MASONRY MORTAR JOINTS. MINOR TO MODERATE EFFLORESCENCE, SOME WITH RUST STAINING

ON MASONRY STONE WALLS.

MINOR SPALLING WITH UP TO 40% SECTION LOSS ON EXPOSED REBAR DUE TO INSUFFICIENT CONCRETE COVER ON BARREL

CEILING AT MASONRY WALL INTERFACE.

62.3

62.4

MINOR DETERIORATION OF WINGWALL AND HEADWALL MASONRY MORTAR JOINTS; MINOR EFFLORESCENCE AND VEGETATION

GROWTH IN JOINTS.

62.10

222.4

MINOR RANDOM CRACKING OF ASPHALT PAVEMENT OVER STRUCTURE AND APPROACHES. MINOR VEGETATION GROWTH IN MEDIAN. MODERATE POTHOLE (8" DIAMETER X 3"D) IN SOUTHBOUND LANES AT SOUTH APPROACH.

62.12 MODERATE VEGETATION GROWTH ADJACENT TO WEST WINGWALLS; MINOR TO MODERATE VINE GROWTH ON WEST

WINGWALLS.

MINOR TO MODERATE LOSS OF FILL FROM WEEP HOLES.

222.7 REFLECTIVE OBJECT MARKERS NOT PRESENT AT STRUCTURE ENDS.

36.C

36.D

GUARDRAIL SYSTEM NOT PRESENT.

H 15 14 15 14

HS 36 33 36 33

TYPE 3 25 23 25 23

TYPE 3S2 36 33 36 33

TYPE 3-3 40 36 40 36

2 - H 15

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

11/03/2016

LOAD RATING IS BASED ON ENGINEERING JUDGEMENT IN ACCORDANCE WITH AASHTO MANUAL FOR BRIDGE EVALUATION (MBE), AND HAS BEEN REDUCED DUE TO UNDERMINING OF BARREL WALLS. SEE STRUCTURE FILE FOR LOAD RATING CALCULATIONS.

TWO M LE BRANCH CULVERT INSPECTION DATE: 05/11/2022

(201) PARK: GREAT SMOKY MOUNTAINS NATIONAL PARK

(202) STRUCTURE NAME:..............TWO MILE BRANCH CULVERT

(203) STRUCTURE KIND:............... 2 - CULVERT

(204) STRUCTURE NUMBER:.........5460-211 P

4 - SOUTHEAST(205) NPS REGION:

(206) ROUTE CODE NUMBER:

(207) ROAD SECTION NO:............. 211P

(208) NPS ROAD CLASS:............... 1 - PRINCIPAL PARK ROAD

(209) WITHIN NPS BNDRY?:.......... Yes

(210) OPERATING UNIT:.................N. DIST.

(211) PROJECT NO(S):

(212) DRAWING NUMBERS:

(21) MAINTAINED BY:......................66 - NATIONAL PARK SERVICE

(22) OWNER:................................... 66 - NATIONAL PARK SERVICE

(1) STATE:

(2) STATE HWY. AGENCY DIST:

(3) COUNTY CODE:

(4) CITY / PLACE CODE:

(5) INVENTORY ROUTE:

(6) FEATURES INTERSECTED:

(7) FACILITY CARRIED:

(8) STATE STRUCTURE NO:

(9) LOCATION:

(10) INV. RTE. - MIN. VERT. CLR:

(11) MILE POINT:

(27) YEAR BUILT:

(106) YEAR RECONSTRUCTED:

(20) TOLL:

(37) HISTORIC DESIGNATION:

474 - TENNESSEE

47155 SEVIER

00000

1 6 4 00010 0

TWO MILE BRANCH

NEWFOUND GAP ROAD

5460211P0000000

JUST NORTH OF ENTRANCE TO

SUGARLAND RIDING STABLES, JUST

SOUTH OF GATLINBURG.

99.99 FT ( 99.99 M)

1.10 (KM PT: 1.77 )

3 - ON FREE ROAD

3 - MAY BE ELIGIBLE FOR NATIONAL

REGISTER

(43A) MAIN STR. MATERIAL:..........1 - CONCRETE (44A) APPR. STR. MATERIAL:............ 0 - Other

(43B) MAIN STR. TYPE:.................. 19 - CULVERT (INCLUDES FRAME (44B) APPR. STR. TYPE:.................... 00 - OTHER

CULVERTS)

(45) NO. OF MAIN SPANS:..............002 (46) NO OF APPROACH SPANS:

(48) MAX. SPAN LENGTH:..............9.0 FT ( 2.7 M)

(49) STRUCTURE LENGTH:........... 20.0 FT ( 6.1 M) (108) WEAR SURFACE/PROTECT SYSTEM:

(216A) ABUTMENT #1 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L A) TYPE WEARING SURFACE:.. N - NA

(216B) ABUTMENT #2 FDN:........... 2 - SPREAD FTG ON BEARING MAT'L B) TYPE MEMBRANE:................. N - NA

(217A) PREDOM. PIER FDN:.......... 2 - SPREAD FTG ON BEARING MAT'L C) TYPE PROTECTION:.............. N - NA

(217B) SECOND. PIER FDN:.......... 2 - SPREAD FTG ON BEARING MAT'L (218) IS SALT USED?.......................... NO

(107) DECK TYPE:.......................... N - NOT APPLICABLE

(31) DESIGN LOAD:.........................2 - H 15 (41) LOAD RESTRICTION:.................. A - OPEN

(66) INVENTORY RATING:..............36.0 METRIC TONS) (70) BRIDGE POSTING:...................... 5 - EQUAL TO OR ABOVE LEGALTONS ( 32.7

LOADS

(64) OPERATING RATING:..............36.0 TONS ( 32.7 METRIC TONS)

(90) INSPECTION DATE: 05/12/2022 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL:.......... N

(220) SPECIAL STUDY TYPE: INSP. EVERY MONTHS - LAST INSP:

(221) SPECIAL STUDY DATE: (B) UNDERWATER:..................... N

INSP. EVERY MONTHS - LAST INSP:

(C) SPECIAL INSPECTION:........ N

INSP. EVERY MONTHS - LAST INSP:

TWO M LE BRANCH CULVERT INSPECTION DATE: 05/11/2022

(16) LATITUDE:................................ 35 41'33 00" N (51) CURB TO CURB WIDTH:............ 0 0 FT ( 0 M)

(17) LONGITUDE:............................ 83 31 '54 80" W (52) DECK WIDTH:.......................... 0 0 FT ( 0 M)

(19) DETOUR LENGTH:.................. 48 MI ( 77 KM) (32) APPR. ROADWAY WIDTH:...... 36.0 FT ( 11 M)

(28A) LANES ON STRUCT:.............03 (213) APPR. PAVEMENT WIDTH:... 36.0 FT ( 11 M)

(28B) LANES UNDER STRUCT:......00 LEFT SHOULDER:............... 3 0 FT ( 0.9 M)

(42A) SERVICE ON:.........................1 - HIGHWAY RIGHT SHOULDER:.......... 3 0 FT ( 0.9 M)

(42B) SERVICE UNDER:................. 5 - WATERWAY (33) BRIDGE MEDIAN:.................... 2 - CLOSED MEDIAN (NO BARRIER)

(29) AVG DAILY TRAFFIC:..............1410 (34) SKEW ANGLE:

(30) YEAR OF ADT:......................... 2019 (35) STRUCTURE FLARED:............ 0 - NO FLARE

(114) FUTURE ADT:.........................1692 (47) TOTAL HORIZ. CLEARANCE:.. 44.6 FT ( 13.6 M)

(115) YEAR OF FUTURE ADT:........2039 (50) SIDEWALKS

(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 0 0 FT ( 0 M)

(38) NAVIGATION CONTROL:.........N - NOT APPLICABLE, NO WATERWAY RIGHT:.................................. 0 0 FT ( 0 M)

(39) VERTICAL CLEARANCE:.........0.0 FT ( 0 M) (214) BRIDGE RAIL TYPE

(40) HORIZ. CLEARANCE:..............0.0 FT ( 0 M) RAIL CONFIGURATION:...... 0 - N/A

(111) ABUT OR PIER PROT:........... MATERIAL:........................... 0 - N/A

LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 0 - N/A

(55) RIGHT:...............................00 FT ( 0 M) (215) BRIDGE RAIL HEIGHT:.......... .00 FT ( 0 M)

(56) LEFT:................................ 0 FT ( 0 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)

(54) MIN. VRT. UNDRCLRANCE:... 0 00 FT ( 0 M)

(58) DECK:.......................................N (67) STRUCTURAL EVALUATION:

(59) SUPERSTRUCTURE:...............N (68) DECK GEOMETRY:......................N

(60) SUBSTRUCTURE:.......... N (69) UNDERCLEARANCES:................ N

(61) CHANNEL:................................6 (71) WATERWAY ADEQUACY:

(62) CULVERT:.................................4 (72) APPROACH ALIGNMENT:

(222) APPROACHES:...................... 7 (113) SCOUR CRITICAL:.................... 4 - ACTION IS REQUIRED TO

PROTECT EXPOSED FOUNDATIONS

(223) RETAINING WALL:.................N (225) PURPOSE OF IMPROVEMENT: 2 - REHAB/RECONSTRUCTION

(36) TRAFFIC SAFETY FEAT: N N 0 0 (226) PRIORITY OF IMPROVEMENT: B - MAJOR

(75A) TYPE OF WORK:................... (227) MAINTENANCE COST:.............$ 4500

(75B) WORK DONE BY:.................. (228) REHAB / RECNSTR COST:..... $ 130000

(76) IMPROVEMENT LENGTH:....... FT ( 0 M) (229) CONSTRUCTION COST:.......... $ 0

(230) STRUCTURE HISTORY:

2012-ROADWAY REPAVED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIGURATION INFORMATION:

STRUCTURE WAS ORIG. CONSTRUCTED AS A MASONRY CULVERT WITH A BARREL LENGTH OF 31'. IT WAS LATER EXTENDED AN ADDITIONAL 17' ON

WEST SIDE WITH CAST-IN-PLACE CONCRETE AS PART OF ROADWAY WIDENING PROJECT.

$ 4500

$ 130000

(229) CONSTRUCTION COST:.......... $ 0

Inspector: Osama Tariq Structure Number: 5460211P0000000

Inspection Date: 05/12/2022 Facility Carried: NEWFOUND GAP ROA

Culvert Inspection Report

Pictures

PHOTO 3

Description LOOKING SOUTH TOWARD NEWFOUND GAP

PHOTO 4

Description WEST (DOWNSTREAM) SIDE; NOTE VEGETATION GROWTH

Culvert Inspection Report

Pictures

PHOTO 5

Description GENERAL TOPSIDE VIEW LOOKING NORTH

PHOTO 6

Description TYPICAL CRACKING OF ASPHALT PAVEMENT OVER STRUCTURE; SOUTHBOUND LANE

SHOWN

Culvert Inspection Report

Pictures

PHOTO 7

Description POTHOLE ON SOUTH APPROACH PAVEMENT IN SOUTHBOUND LANES

PHOTO 8

Description GENERAL UNDERSIDE VIEW LOOKING EAST, NORTH BARREL

Culvert Inspection Report

Pictures

PHOTO 9

Description GENERAL VIEW OF SOUTH WALL, SOUTH BARREL

PHOTO 10

Description GENERAL VIEW OF SOUTH WALL, NORTH BARREL

Culvert Inspection Report

Pictures

PHOTO 11

Description TYPICAL TRANSVERSE CRACKING WITH EFFLORESCENCE ON BARREL CEILING; SOUTH

BARREL NEAR MID-LENGTH SHOWN

PHOTO 12

Description TYPICAL SPALLING WITH SECTION LOSS ON EXPOSED REBAR ON BARREL CEILING AT

MASONRY WALL INTERFACE; MID-LENGTH OF NORTH BARREL SHOWN

Culvert Inspection Report

Pictures

PHOTO 13

Description TYPICAL EFFLORESCENCE ON HEADWALL FASCIA MASONRY RING STONES; WEST SIDE

OF SOUTH BARREL SHOWN

PHOTO 14

Description TYPICAL DETERIORATION OF BARREL WALL MASONRY MORTAR JOINTS WITH

EFFLORESCENCE AND RUST STAINING; SOUTH WALL OF SOUTH BARREL SHOWN

Culvert Inspection Report

Pictures

PHOTO 15

Description TYPICAL LOSS OF FILL FROM WEEP HOLES; SOUTH WALL IN SOUTH BARREL NEAR EAST

END SHOWN

PHOTO 16

Description VOID UNDERNEATH MASONRY FOOTING IN NORTH WALL OF NORTH BARREL NEAR MID-

LENGTH

Culvert Inspection Report

Pictures

PHOTO 17

Description SCOUR WITH UNDERMINING OF MASONRY FOOTING NEAR UPSTREAM END OF NORTH

WALL IN NORTH BARREL

PHOTO 18

Description VOID UNDERNEATH MASONRY FOOTING NEAR MID-LENGTH OF INTERMEDIATE WALL

WITH WATER FLOWING UNDER WALL, NORTH BARREL

Culvert Inspection Report

Pictures

PHOTO 19

Description LOOKING UPSTREAM THROUGH NORTH BARREL; NOTE DRIFT

PHOTO 20

Description LOOKING DOWNSTREAM THROUGH NORTH BARREL