Bldg 32 Arch As Builts - Copy.pdf
PDF 1 MB Posted
- Solicitation number
- 36C24826Q0188
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
C4 A-203
F4 A-201
F4 A-203
C4 A-201
1"
WAITING ROOM
030-32
STORAGE
031-32
CO
RR
ID
O R
C0 -0 5-
RESTROOM
027-32
SO
IL
ED
U
TI
LI
TY
3-
CORRIDOR
C0-07-32
GURNEY
HOLDING
026B-32
VITALS
026C-32
FILE ROOM
026-32
OFFICE
026a-32
CO
RR
ID
O R
C0 -0 8-
CHIEF THERAPIST
048D32
SE
RV
ER
8E -3
048-32
EXAM ROOM
047-32
8B -3
8C -3
WAITING
048A-32
H.A.C 050-32
ST
AF
F
LO
U N G E
9-
MENS RESTROOM
049A-32
WOMENS RESTROOM
049B-32
A.A/CHIEF
THERAPIST
051-32
FE
M
AL
E
LO
CK
ER
S
9c -3
M
AL
E
LO
CK
ER
S
9d -3
CO
RR
ID
O R
C0 -0 9-
Co nt ro l A re a
5a -3
SIMULATOR ROOM
025-32
ULTRASOUND ROOM
022-32
024-32
THERAPIST
023-32
THERAPIST
040-32
EXAM ROOM
037-32
EXAM ROOM
046-32
CORRIDOR
C0-01-32
EXAM ROOM
044-32
EXAM
ROOM
043-32
SI
G N
AL
/T
EL
EP
H O N E
9-
EXAM ROOM
042-32
ELECTRIC
017-32
PHYSICIST OFFICE
018-32
DO
SI
M
ET
RI
ST
O
FF
IC
E
0a -3
WAITING ROOM
018A-32
CO
RR
ID
O R
C0 -0 2-
018B-32 018c-32
018d-32
CORRIDOR
C0-04-32
BONE SCAN
056-32
RADIATION
ONCOLOGY
055-32
RE
ST
RO
O M
8-
COMPUTER
PLANNING
020-32
PHYSICIST OFFICE
019-32
CH
EC
K
IN
3C -3
O
FF
IC
E
3B -3
2 DIETICIAN
OFFICE
013A-32
SOCIAL
WORKER
013-32
ST
O
RA
G E
2-
HOLDING
AREA
011-32
CORRIDOR
C0-30A-32
MRI
007-32
CONTROL
ROOM
006-32
003-32
CORRIDOR
C0-03-32
002-32001-32
CORRIDOR
C0-01-32
EQ
U
IP
M
EN
T
8-
UNDER
CONSTRUCTION
009-32
UNDER
CONSTRUCTION
009a-32
ELEVATOR MACHINE
ROOM
001-32
DRESSING
ROOM
005-32
CONNECTING
CORRIDOR
C0-01-CC
STAIRS #1
S0-01-32
ST
AI
RS
S0 -0 2-
IMPLANTS ROOM
034C-32 GENERAL STORAGE
035C-32
23 MEV LINEAR
ACCELERATOR
035B-32
23 MEV LINEAR
ACCELERATOR
034B-32
6-10 LINEAR
ACCELERATOR
034a-32
ELECTRIC
032-32
CLEAN LINEN
036-32
CONTROL ROOM
034-32
CONTROL ROOM
035-32
1'
- 7
8'
- 3
9" 1'
- 2
1"
2'
- 3
1'
- 1 0"
9'
- 2
4'
- 0
8'
- 7
1"
6" 3'
- 2
4'
- 7
19' - 3" 11' - 7" 2' - 7"
12' - 6" 8' - 1" 12' - 9" 11" 36' - 7"
8'
- 6
9'
- 8
8'
- 1 0"
7'
- 7 1'
- 1
5'
- 9 1'
- 5 1'
- 5
8'
- 6
0"
1'
- 2
10' - 9" 12' - 3"
1' - 2"
1' - 10"
4' - 9"
4' - 5"
4' - 9"
1' - 9"
9"
14' - 1" 11"
1' - 4"
88' - 5"
2'
- 8
9"
1' - 8"
8' - 2" 16' - 4" 16' - 1"
1'
- 1 1"
1'
- 5
8' - 10" 2' - 5"
10' - 10"
7' - 5" 5' - 8"
6' - 1" 10' - 6" 6' - 8"
6'
- 2
5' - 8"
7' - 1" 12' - 6" 13' - 2"
30' - 1"
20' - 9" 3' - 7" 6' - 10" 10' - 9" 2' - 2" 5' - 2"
3'
- 1 1"
8'
- 3
10' - 9" 11' - 10"
11' - 2"
10' - 5"
8' - 9"
6' - 10"
8' - 5"6' - 1"
6'
- 3
10' - 0" 11' - 5"
5'
- 2
6'
- 2
1' - 6"
12' - 0" 9' - 4"
13' - 5" 6' - 5"
1'
- 9
2' - 5" 12' - 11" 5' - 7" 1' - 5"
9' - 2"
4' - 6" 4' - 5" 6' - 7" 1' - 9" 6' - 9"
8'
- 6 "2'
- 9
"12' - 2"
11' - 11"
6'
- 3
5'
- 6 " 7'
- 2
4'
- 3
8'
- 7
6' - 5" 9' - 10" 7' - 3"
9" 6' - 7"
11' - 8"11' - 10"
5'
- 4
5' - 5" 7' - 1" 11' - 0"
0"
23' - 6"
8'
- 6
6' - 10" 6' - 11"
5' - 10" 6' - 4" 9' - 9"
4'
- 5
5'
- 1
7'
- 1 0"
4'
- 5
6'
- 1 0"
6'
- 4 7'
- 3
6' - 5" 6' - 8"
6' - 6"
11' - 9"
11' - 3" 4"
9' - 9" 1' - 10"
4'
- 5
5' - 1"
12' - 3" 11' - 9"
22' - 7" 1' - 4"
11' - 4"
6' - 3"
4'
- 1 1"
6'
- 3
6'
- 2
13' - 2"
13' - 8"
8' - 7"
3'
- 4
9"
2' - 10" 2' - 8"
6' - 11"
4' - 11" 3' - 0"
7' - 3" 1' - 11" 7' - 3"
2' - 11"
21' - 1"
2' - 6" 4' - 1" 9' - 5" 5' - 0"
2'
- 9
1'
- 1 1" 7"
7'
- 6
4' - 7" 3' - 9"
5' - 5"
6' - 11"
6'
- 1 1"
6" 1'
- 7
9" 9'
- 7
6" 8'
- 0 1'
- 6 "30' - 4" 6' - 2" 2' - 2" 6' - 9"
6' - 7" 11' - 8"
8'
- 6
37' - 4"
8'
- 9
7' - 9"
12' - 11"
9'
- 7 "13' - 0"
7' - 8" 4' - 2"
5' - 3"
6' - 9" 1' - 8"
1' - 4"
17' - 11" 2' - 6"
3' - 2"
3' - 5"
3'
- 3
3' - 8"
3'
- 2
6"
3'
- 2
9"
13' - 10" 17' - 4"
20' - 7"
1' - 8"7'
- 0
3'
- 3 " 7' - 3"
8"
2' - 7"
22' - 6"
4'
- 2
1'
- 4
10' - 2"
12' - 8"
13' - 0"
9' - 5" 3' - 8"
8' - 4"
6'
- 5
8'
- 8 "11' - 7"
9" 8' - 8"
6'
- 6
UP
FLOOR PLAN LEGEND
TOILET
SINK
URINAL
SINK WITH COUNTER
A.
B.
ALL DIMENSIONS ARE TO THE CENTERLINES OF WALLS UNLESS
OTHERWISE NOTED
VERFIY ALL DIMENSIONS IN FIELD PRIOR TO ANY DEMOLITION OF
EXISTING CONDITIONS OR NEW CONSTRUCTION
FLOOR PLAN NOTES
N
S
EW
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseDESIGNER OF RECORD A/E:
STAMPCONSULTANT
7 8 9 10
BIM MODELLING:
321 4 5 6
Office of Construction and
Facilities
GRAPHIC SCALE
GENERAL NOTE
DUE TO POINT CLOUD DRIFT, THERE MAY BE SOME DEVIATION
BETWEEN THE MODEL AND THE POINT CLOUD.
C :\U se rs
\jo e.
bo ot h\ O ne D riv e
- R es ol ut io n\
D es kt op
\V A fin al s\ Bu ild in g
\B ui ld in g
As
B ui lt_ R
_d et ac he d.
rv t
4/
/2
:4 0:
P
M
A-102
BUILDING 32 - FIRST FLOOR PLAN
HORSEPOWER GEOSPATIALRESOLUTION LLC
UPDATING CAMPUS SITE MAPPING
AND FACILITY AS-BUILTS
JAMES A HALEY VETERANS HOSPITAL (TAMPA, FL)
673-23-101
10/08/24 CDS / CEW JMB
AS-BUILT CONDITIONS
1525 SPARKMAN DR. NW STE A
HUNTSVILLE, AL 35816
(256) 520-4341
JEFF LOWER
1525 SPARKMAN DR. NW STE A
HUNTSVILLE, AL 35816
(256) 520-4341 JEFF LOWER Approver
3/32" = 1'-0"F4 FIRST FLOOR PLAN
3/32" = 1' - 0"
0 5' 10' 20' 40'
Revisions: Date:
MODELING 4/2/24
REVISIONS 9/25/24
REVISION 11/13/2025
First Floor Square Footage vg Room Name Area
001-32 228 SF
001-32 ELEVATOR MACHINE ROOM 194 SF
002-32 117 SF
003-32 120 SF
005-32 DRESSING ROOM 67 SF
006-32 CONTROL ROOM 148 SF
007-32 MRI 445 SF
008-32 EQUIPMENT 221 SF
009-32 UNDER CONSTRUCTION 454 SF
009a-32 UNDER CONSTRUCTION 452 SF
011-32 HOLDING AREA 87 SF
012-32 STORAGE 58 SF
013-32 SOCIAL WORKER 140 SF
013A-32 DIETICIAN OFFICE 133 SF
013B-32 OFFICE 73 SF
013C-32 CHECK IN 55 SF
017-32 ELECTRIC 45 SF
018-32 PHYSICIST OFFICE 152 SF
018A-32 WAITING ROOM 241 SF
018B-32 127 SF
018c-32 134 SF 018d-32 148 SF
019-32 PHYSICIST OFFICE 77 SF
020-32 COMPUTER PLANNING 262 SF
020a-32 DOSIMETRIST OFFICE 131 SF
022-32 ULTRASOUND ROOM 229 SF
023-32 THERAPIST 112 SF
024-32 ---- 84 SF
025-32 SIMULATOR ROOM 302 SF
025a-32 Control Area 79 SF
026-32 FILE ROOM 511 SF
026a-32 OFFICE 116 SF
026B-32 GURNEY HOLDING 74 SF
026C-32 VITALS 46 SF
027-32 RESTROOM 51 SF
030-32 WAITING ROOM 406 SF
031-32 STORAGE 247 SF
032-32 ELECTRIC 68 SF
033-32 SOILED UTILITY 78 SF
034-32 CONTROL ROOM 716 SF
034a-32 6-10 LINEAR ACCELERATOR 532 SF
034B-32 23 MEV LINEAR
ACCELERATOR
509 SF
034C-32 IMPLANTS ROOM 125 SF
035-32 CONTROL ROOM 511 SF
035B-32 23 MEV LINEAR
ACCELERATOR
558 SF
035C-32 GENERAL STORAGE 120 SF
036-32 CLEAN LINEN 156 SF
037-32 EXAM ROOM 108 SF
038-32 RESTROOM 49 SF
039-32 SIGNAL/TELEPHONE 154 SF
040-32 THERAPIST 115 SF
042-32 EXAM ROOM 118 SF
043-32 EXAM ROOM 160 SF
044-32 EXAM ROOM 121 SF
046-32 EXAM ROOM 125 SF
047-32 EXAM ROOM 128 SF
048-32 ---- 130 SF
048A-32 WAITING 75 SF
048B-32 40 SF
048C-32 42 SF
048D32 CHIEF THERAPIST 57 SF
048E-32 SERVER 20 SF
049-32 STAFF LOUNGE 218 SF
049A-32 MENS RESTROOM 44 SF
049B-32 WOMENS RESTROOM 57 SF
049c-32 FEMALE LOCKERS 118 SF 049d-32 MALE LOCKERS 116 SF
050-32 H.A.C 143 SF
051-32 A.A/CHIEF THERAPIST 221 SF
055-32 RADIATION ONCOLOGY 141 SF
056-32 BONE SCAN 146 SF
File details come from the government source that posted it. Updated .