This document is a specifications and design plan for physical barriers at a federal facility. The file contains architectural plans (drawing 03.PLAN.100) and product specifications for rectangular planter bollards to be procured and installed around a Diagnostic and Testing facility.

The specified barrier product is a rectangular planter bollard manufactured by Petersen MFG (Model P96X30X36, Item 31EY40) in gray concrete with the following dimensions: 36 inches overall height, 30 inches overall width, and 96 inches overall length. The bollard features an internal cavity for plants and a drainage hole at the base. Key material specifications include concrete construction with a lite sand blast finish, 3-inch wall thickness, and a weight of 3,950 pounds per unit. The product must comply with standards ASTM C150 Type 1 or 3 and ASTM C33, with UNSPSC code 21101601. The document indicates the bollards are manufactured in the USA and are sold by the each (EA). Multiple barriers are to be positioned around the facility perimeter, with specific placement shown on the architectural plan including offsets of 10 feet from the building exterior and 4-foot maximum spacing between barriers. The procurement document specifies that procured barriers shall be similar in physical and standard specifications to the example provided, with similar approved alternates acceptable.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

10'-0" OFF EXT. OF BLDG.

BARRIER BARRIER

4'-0" MAX.

BARRIER

4'-0" MAX.

BAR

R

IER

BARRIER

10'-0" OFF EXT. OF BLDG.

BARRIER

4'-0" MAX.

4'-0" MAX.

EXISTING OUTSIDE PERIMETER OF

3 - DIAGNOSTIC AND TESTING - F/D

10'-0" OFFSET FROM

3 - DIAGNOSTIC AND TESTING - F/D

BAR

R

IER

BARRIER

PURPOSED ALTERNATE POSITION

FOR ADDITION BARRIERS

4'-0" MAX.

AMBULATORY

PEDESTRIAN

ENTRANCE

AMBULATORY

CART ENTRANCE

6'-0" MAX.

4'-0" MAX.

8'-0"

2'-6"BARRIER

Pr oj ec t n um be r:

RM

RV

AM

C

Da te

D es ig ne d By

D ra w n By

O

FF

IC

E O

F

CO

NS

TR

UC

TI

O N

AN

D

FA

CI

LI

TI

ES

M

AN

AG

EM

EN

T

ED

B

AR

RI

ER

P

RO

PO

SI

TI

O N

PL

AN

AU

RO

RA

, C

O

LO

RA

DO

Pr oj ec t T itle

Lo ca tio n:

Sc al e:

O

FF

IC

E

O F

CO

NS

TR

UC

TI

O

N

AN

D

FA

CI

LI

TI

ES

M

AN

AG

EM

EN

T

/1

4/

1:

:1

AM

C

:\U se rs \V

H

AE

C H

W illi

Se a\

O ne

D riv e

- D ep ar tm en t o f V et er an s

Af fa irs \D oc um en ts

\A S-

C

EN

TR

AL

_V H

AE

C

H W illi Se a.

rv t

0'

-0

.P

LA

N.

/1

4/ 25N P

SW

ED

B

AR

R

IE

R

P

LA

N

1" = 10'-0"1 PHYSICAL BARRIER - ED PLAN

1" = 10'-0"2 BARRIER DETAIL

VHAECHKAWAKS

Highlight

VHAECHKAWAKS

Text Box Procured barrier shall be similar in physical and standard specifications as the example provided on the following pages of this document.

Product Description These rectangular-shaped planter bollards have an internal cavity for plants and a hole at their base to provide a drain for watering.

VHAECHKAWAKS

Image

File details come from the government source that posted it. Updated .