Attachment B - ROGUE VALLEY_OYA_FULL SET.pdf
PDF 13 MB Posted
- Solicitation number
- S-DASOBO-00009651
- Issued by
- Hood River County, Jackson County, Linn County, Albany City, Oregon
About this file
This document is an attachment related to a state and local contract opportunity in Oregon for control room renovations at three youth correctional facilities: Eastern Oregon Youth Correctional Facility, Oak Creek Youth Correctional Facility, and Rogue Valley Youth Correctional Facility. The purpose of this Invitation to Bid (ITB) is to establish a contract to update the control rooms at these facilities located in Harney, Josephine, and Linn counties. The contract will cover the necessary services and products required for these renovations. The due date for responses is not provided in the information given.
Pricing terms, set-asides, incumbents, funding requirements and sources, and other salient contract details are not included in the information provided. The document appears to be focused on the project scope, locations, and facilities involved.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:12 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
J A
M
K J A
M
K J B
J B
OYA-000
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
C O
V E
R S
H E
E T
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
OREGON YOUTH AUTHORITY
REGIONAL FACILITIES
CONTROL ROOM UPGRADE
ROGUE VALLEY YOUTH CORRECTIONAL FACILITY
DECEMBER 2023
JACOBS PROJECT NO. D3482000
SHEET LIST
DRAWING DRAWING TITLE DISCIPLINE REV DATE
OYA-000 COVER SHEET COVER SHEET 0 12/10/2023
OYA-001 LEGENDS & ABBREVIATIONS ARCHITECTURE 0 12/10/2023
OYA-002 CODE PLAN ARCHITECTURE 0 12/10/2023
OYA-100 FIRST FLOOR PLAN OVERALL ARCHITECTURE 0 12/10/2023
OYA-200 DEMOLITION PLAN ARCHITECTURE 0 12/10/2023
OYA-300 ENLARGED FLOOR PLAN & FINISH ARCHITECTURE 0 12/10/2023
OYA-301 ENLARGED CEILING PLAN ARCHITECTURE 0 12/10/2023
OYA-302 ENLARGED FURNITURE PLAN AND EQUIPMENT ARCHITECTURE 0 12/10/2023
OYA-500 INTERIOR ELEVATIONS ARCHITECTURE 0 12/10/2023
OYA-600 DETAILS ARCHITECTURE 0 12/10/2023
OYA-700 DOOR AND ROOM SCHEDULES & FINISH LEGEND ARCHITECTURE 0 12/10/2023
PROJECT LOCATION
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
VICINITY MAP
OYA-E301 LIGHTING PLAN ELECTRICAL 0 12/10/2023
OYA-E302 POWER PLAN ELECTRICAL 0 12/10/2023
OYA-M100 FLOOR PLAN MECHANICAL 0 12/10/2023
OYA-ES0001 LEGEND ABBREVIATIONS & GENERAL NOTES SECURITY 0 12/10/2023
OYA-ES1000 SECURITY PLAN SECURITY 0 12/10/2023
OYA-ES4701A DOOR CONTROL LOOP TERM. WIRING - PANEL 1 SECURITY 0 12/10/2023
OYA-ES4701C DOOR CONTROL LOOP TERM. WIRING - PANEL 1 SECURITY 0 12/10/2023
OYA-ES4701E DOOR CONTROL LOOP TERM. WIRING - PANEL 1 SECURITY 0 12/10/2023
OYA-ES7201 SECURITY DOOR DETAILS SECURITY 0 12/10/2023
OYA-ES7210 SECURITY DETAILS SECURITY 0 12/10/2023
11/29/2023
H
S
VENT
INSULATION
GYPSUM BOARD
FINISHES
ACOUSTICAL TILE
BATT/LOOSE FILL
RIGID
WOOD
PLYWOOD
BLOCKING
ROUGH
STEEL
FINISH
MASONRY
METAL
ALUMINUM
SAND
BRICK OR CMU
EARTHWORKS
CONCRETE
MATERIAL LEGEND
CONCRETE
GRAVEL
EARTH
FURRING ZEE CHANNEL
SLOTTED CHANNEL FRAMING
CURTAIN WALL /
STORE FRONT
FIXED
SLIDING
WINDOW TYPES
ROUND CONCRETE COLUMN
STEEL DECKING
CONCRETE & STEEL DECKING
CONCRETE BEAM OR GIRDER
STEEL BEAM OR GIRDER
JOIST OR GIRDER(ELEVATION)
C - METAL STUD
SHAFTWALL STUD
FURRING HAT CHANNEL
METAL STUD RUNNER
STEEL ANGLE
STEEL CHANNEL
FIRE PROTECTION
SMOKE DETECTOR
HEAT DETECTOR
SPRINKLER
FIRE EXTINGUISHER
SPEAKER
CLOCK
MISC. ARCHITECTURAL
CORNER GUARD TUBE STEEL COLUMN
STEEL PIPE COLUMN
WIDE FLANGE COLUMN
SQUARE CONCRETE COLUMN
BUILDING SYSTEM LEGEND
STRUCTURAL
ARCHITECTURAL ABBREVIATIONS
ARROW AT ROOF PLANS
INDICATES SLOPE AND
DOWN DIRECTION
ARROW AT STAIR PLANS
INDICATES UP OR DOWN
DIRECTION
CONCRETE COLUMN WITH
EMBEDDED UNISTRUT
POWER AND
COMMUNICATIONS
PP
POWER POLE
CR
CARD READER
OVERHEAD COILING
SLIDING (BREAKAWAY)
SLIDING
SINGLE (TWO WAY)
DOUBLE (180 DEGREES)
DOUBLE (TWO WAY)
DOUBLE
SINGLE W/ SIDE LITE
SINGLE (180 DEGREES)
DOOR TYPES
SINGLE
CIP WATERSTOP
UP
DN
X"/X"
FE-XX FE- TYPE
GENERAL NOTES
S. PATCH/REPAIR: WHERE EXISTING WALLS, FLOORS,CEILING
OR ROOFS HAVE BEEN DISTURBED BY DEMOLITION OR
CONSTRUCTION, OR WHERE EXISTING OPENINGS REMAIN
AFTER REMOVAL OF DUCTS, PIPING, CONDUIT, ETC. PATCH
AND RESTORE EXISTING WITH NEW MATERIALS AS REQUIRED
TO MATCH EXISTING SURFACES. PAINT ENTIRE SURFACE FULL
HEIGHT AND WIDTH. SEE ROOM FINISH SCHEDULE DRAWING.
PATCH CONCRETE FLOORS TO PROVIDE A SMOOTH LEVEL
SURFACE TO ACCEPT NEW FINISH.
T. PRIOR TO DEMOLITION, BEARING WALLS AND STRUCTURAL
MEMBERS SHALL BE LOCATED, ANY POTENTIAL CONCERNS
SHOULD IMMEDIATELY BE COMMUNICATED TO THE ARCHITECT.
U. DURING DEMOLITION, BRACING AND/OR SHORING SUPPORTS
SHALL BE REQUIRED TO PREVENT MOVEMENT OR
SETTLEMENT OF THE EXISTING STRUCTURE.
V. ACCESORIES LOCATION, REFERE TO STANDARD MOUNTING
HEIGHTS AND REQUIRMENTS ON SHEET OYA- 001. UNLESS
OTHERWISE NOTED.
W. SALVAGE TO OWNER ALL REMOVED FIXTURES, FITTINGS, DOORS
AND FRAMES.
X. FOR FIRESTOPPING REFER TO SPECIFICATION 07 84 00.
Y. FOR METAL RAILINGS SEE SPEC 05 52 00 FOR MORE INFORMATION.
A. THIS IS A STANDARD LEGEND SHEET WHICH CONTAINS INFORMATION THAT
MAY NOT BE USED.
B. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE
WITH AMERICANS WITH DISABILITIES ACT MOUNTING HEIGHTS.
C. SUPPLY AND INSTALL CONTRACTORS SHALL VERIFY DIMENSIONS AND
CONNECTION POINTS PRIOR TO FABRICATION.
D. DIMENSIONS SHOWN ON THE FLOOR PLANS FOR GWB PARTITIONS ORIGINATE
AT COLUMN GRID LINES AND EXTEND TO FACE OF STUD, TYPICAL UNLESS
NOTED OTHERWISE.
E. MAINTAIN INTEGRITY OF FIRE RATED PARTITIONS BY PROVIDING FIRE
BARRIERS AT ALL OPENINGS, GAPS AND VOIDS. SEAL LARGE OPENINGS USING
MATERIALS CONSISTENT WITH WALL CONSTRUCTION. SEAL GAPS AND JOINTS
BETWEEN CONSTRUCTION MATERIALS USING A UL APPROVED FIRE RESISTANT
SEALER/FILLER.
F. DOORS ARE LOCATED 6" OFF ADJACENT WALL UNLESS OTHERWISE NOTED.
G. ALL WORK METHODS OF CONSTRUCTION ARE TO COMPLY WITH ALL FEDERAL,
STATE, REGIONAL AND LOCAL BUILDING REQUIREMENTS.
H. DO NOT SCALE DRAWINGS.
I. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS AND
CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO
CONSTRUCTION.
J. THESE DOCUMENTS MAY NOT INDICATE THE ACTUAL FIELD CONDITIONS. THE
CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND
COORDINATE WITH OTHER CONTRACTORS PRIOR TO STARTING WORK.
K. ALL MATERIALS AND SYSTEMS ARE TO BE CONSIDERED NEW UNLESS
OTHERWISE NOTED.
L. CONTROL JOINTS IN GYPSUM WALLS:
1. IN LONG EXPANSES SUCH AS CORRIDORS, CONTROL JOINTS SHOULD BE
PLACED AT A MAXIMUM OF 30 FEET. PROVIDE CONTROL JOINTS IN FIRE RATED
PARTITIONS AS RECOMMENDED BY MANUFACTURER. PROVIDE CONTROL
JOINTS AT ALCOVES ABOVE DOOR OPENINGS ALIGNED WITH SIDES OF
ALCOVES.
2. WHERE GYPSUM WALL IS LOCATED ABOVE MASONRY WALL, ALIGN THE
CONTROL JOINTS IN THE GYPSUM WALL WITH THE CONTROL JOINTS IN THE
MASONRY WALL.
M. DIMENSIONS TO EXISTING CONDITIONS ARE APPROXIMATE AND MUST BE FIELD
VERIFIED.
N. FIELD VERIFY ALL CONDITIONS PRIOR TO BEGINNING WORK. SALVAGE
MATERIAL AS DIRECTED BY OWNER.
O. DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED UNLESS NOTED
OTHERWISE.
P. DEMOLITION WORK SHALL BE COORDINATED WITH ALL
STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING, ETC. TRADES PRIOR TO
THE START OF ANY DEMOLITION.
Q. PRIOR TO STARTING DEMOLITION, DUST CONTROL BARRIERS SHALL BE
CONSTRUCTED TO PREVENT THE SPREAD OF DUST INTO SURROUNDING
AREAS. REFER TO SPECIFICATION 02 41 19 SELECTIVE DEMOLITION FOR MORE
INFORAMTION.
R. EXISTING EXITS SHALL BE MAINTAINED AS REQUIRED BY OWNER DURING
DEMOLITION.
0' - 6"
0' - 8"
17" - 19"
" 6
1' - 0"
" 6
0' - 6"
TYPICAL CORRIDOR/AISLE FIXTURES - STANDARD MOUNTING HEIGHTS
ELECTRICAL
OUTLET
TELEPHONE OUTLETS
HOUSE TELEPHONE
MAUNAL PULL STATION
FIRE ALARM SIGNAL
EXIT SIGN
CARD READER AND STRIKE PLATE
INTERCOMMUNICATION
STATION
LIGHT SWITCH
TEMPERATURE SENSOR
STROBE 6'-8" TO BOTTOM
FIRE EXTINGUISHER SIGN
FIRE EXTINGUISHER,
WALL MOUNTED
FIRE EXTINGUISHER,
RECESSED CABINET OR
FIRE EXTINGUISHER,
VALVE CONNECTION
RECESSED CABINET
EMERGENCY
POWER OFF
ANNUNCIATOR PANEL
CORNER GUARD
54" MIN
12" MAX 42" MIN
T .O
B
A R
24" 12"
T .O
B
A R
16" - 18"
60" MIN
"T
Y P
H C
36" MAX
T Y
P
12" MAX
36"
EQ EQ
M A
X
7" - 9"
39" - 41"
36"
/2
6 3/4"
3"
3"
NOTE: MAX HEIGHT TO OPERABLE
PART OF TOILET
ACCESSORIES IS 40"
STANDARD MOUNTING HEIGHTS AND ADA REQUIREMENTS
STANDARD H/C COMPARTMENT
NOTES:
A VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE WITH ADA MOUNTING HEIGHTS.
B DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE HIGHEST PORTION OF THE OPENING OR OPERATING DEVICE U.N.O.
C PROVIDE BACKING FOR INSTALLATION OF ALL WALL-MOUNTED ITEMS.
D PLACE ELECTRICAL AND TELEPHONE DEVICES AT 44 INCHES ABOVE FINISH FLOOR AT CREDENZAS AND COUNTERTOPS U.N.O.
E ALL RESTROOM ACCESSORIES TO BE INSTALLED PER THE MANUFACTURERS RECOMMENDED STANDARD MOUNTING HEIGHT, BUT SHALL NOT
EXCEED THE MAXIMUM REACH DIMENSIONS NOTED ABOVE AND AS REQUIRED BY ICC/ANSI 117.1.
STANDARD COMPARTMENTSTANDARD COMPARTMENT
SCD
TPD
PTD & WASTE UNIT (RECESSED)
COAT/UTILITY HOOKS
SD (NO PROTRUSION)
SANITARY NAPKIN
DISPENSER (RECESSED)
TPD
ND
WHERE
OCCURS
TPD
GB
SCD
GB
SEAT HEIGHT AND GRAB BAR
LOCATIONS
TPD
ND WHERE
OCCURS
SURFACE MOUNTED DISPENSERS PROTRUDING OBJECTS
MOUNTED NEAR GRAB BARS
TO LID T.O. LID
STANDARD H/C COMPARTMENT STANDARD H/C COMPARTMENT STANDARD H/C COMPARTMENT
PTD (RECESSED)
SD (W/PROTRUSION
GREATER THAN 11")
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:12 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
D e s ig n e r
J A
M
K C h e c k e r
A p p ro v e r
OYA-001
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E L E
G E
N D
S
A B
B R
E V
IA
T
IO
N
S
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
Architectural Abbreviations
ABRV Description
RM ROOM
RO ROUGH OPENING
ROM ROUGH ORDER OF MAGNITUDE
RRD RAPID ROLL-UP DOOR
S STAIN
SAC-(#) SUSPENDED ACOUSTICAL CEILING - TYPE
SAT SUSPENDED ACOUSTICAL TILE
SCD SEAT COVER DISPENSER
SD SOAP DISPENSER
SECT SECTION
SF SQUARE FEET
S/H SEALER / HARDENER
SHT SHEET
SIM SIMILAR
S-INSUL STEEL INSULATED
SOW SCOPE OF WORK
SS STAINLESS STEEL OR SOLID SURFACE
STC SOUND TRANSMISSION COEFFICIENT
STD STANDARD
STL STEEL
STRUCT STRUCTURAL
SUSP SUSPENDED
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TR TREAD
TS TUBE STEEL
TYP TYPICAL
UA UNASSIGNED
UL UNDERWRITERS LABORATORY
UMC UNIFORM MECHANICAL CODE
UNO UNLESS NOTED OTHERWISE
UPC UNIFORM PLUMBING CODE
V VENT
VERT VERTICAL
VEST VESTIBULE
VIB VIBRATION
VP VENT PIPE
VR VAPOR RETARDER
W/ WITH
WB-(#) WHITE BOARD - TYPE
WC-(#) WALLCOVERING - TYPE
WD WOOD
WF-(#) WINDOW FILM - TYPE
WOM WALK OFF MAT
W/O WITHOUT
WP-(#) DEMOUNTABLE PARTITION - TYPE
WT WEIGHT
WWP WOVEN WIRE PARTITION
(D) DEMO
(R) RELOCATE
Architectural Abbreviations
ABRV Description
JT JOINT
LAM LAMINATED
LB LOUVERED BLINDS / POUND
LP LOW POINT
LSS LIFE SAFETY SYSTEMS
MAS MASONRY
MATL MATERIAL
MAX MAXIMUM
MB-(#) MARKER BOARD - TYPE
MECH MECHANICAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM; MINUTE
MISC MISCELLANEOUS
MO MASONRY OPENING
MS MOP SINK
MTL METAL
NA NOT APPLICABLE
ND NAPKIN DISPOSAL
NEC NATIONAL ELECTRIC CODE
NFPA NATIONAL FIRE PROTECTION ASSOCIATION
NIC NOT IN CONTRACT
NR NOT FIRE RATED
NTS NOT TO SCALE
NV NAPKIN VENDOR
OC ON CENTER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
OHC OVERHEAD COILING DOOR
OPP OPPOSITE
OSHA OCCUPATIONAL SAFETY AND HEALTH ASSOCIATION
PCF PER CUBIC FOOT
PKG PACKAGE
PL PLATE
PLAM-(#) PLASTIC LAMINATE - TYPE
PLBG PLUMBING
PLYWOOD PLYWOOD
PNL PANEL
PR PAIR
PREFAB PREFABRICATED
PROC PROCESS
PSI POUNDS PER SQUARE INCH
P / T PASS THROUGH
PT-(#) PAINT SYSTEM - COLOR
PTD PAPER TOWEL DISPENSER
R RISER
RA RETURN AIR
RAG RETURN AIR GRILLE
RB-(#) RESILIENT BASE - TYPE
REF REFERENCE
REQD REQUIRED
RF-(#) RESILIENT FLOORING - TYPE
Architectural Abbreviations
ABRV Description
EJ-(#) EXSPANSION JOINT - TYPE
ELEC ELECTRIC
EL/ELEV ELEVATION OR ELEVATOR
EMERG EMERGENCY
EOD EDGE OF DECK
EQ EQUAL
EQUIP EQUIPMENT
EXP EXPOSED
EXT EXTERIOR
FACT FACTORY
FE-(#) FIRE EXTINGUISHER - TYPE
FF FINISH FLOOR
FF&E FURNITURE, FIXTURES AND EQUIPMENT
FFU FAN FILTER UNIT
FG FINISH GRADE
FIN FINISH
FLG FLASHING
FLR FLOOR
FM FACTORY MUTUAL
FMS FACILITIES MANAGEMENT SYSTEM
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOP FACE OF PANEL
FOS FACE OF STUDS / STEEL
FT FOOT/FEET
GA GAUGE
GALV GALVANIZED
GB GRAB BAR
GWB GYPSUM WALL BOARD
GL-(#) GLASS - TYPE
GR GRILLE
GT-(#) GROUT - TYPE
GYP GYPSUM
HB HOSE BIBB
HC HOLLOW CORE
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HPC HIGH PERFORMANCE COATING
HR HOUR
HS HIGH STRENGTH
HT HEIGHT
IBC INTERNATIONAL BUILDING CODE
IECC INTERNATIONAL ENERGY CONSERVATION CODE
IFC INTERNATIONAL FIRE CODE
IN INCH/INCHES
INSUL INSULATION
INT INTERIOR
IPC INTERNATIONAL PLUMBING CODE
IWUIC INTERNATIONAL WILDLANDS URBAN INTERFACE CODE
Architectural Abbreviations
ABRV Description
@ AT
ø DEGREE
° DIAMETER
CENTERLINE
AC-(#) ACOUSTICAL TILE - TYPE
ACP ALUMINUM CHECKER PLATE
ADA AMERICANS WITH DISABILITIES ACT
AF-(#) ACCESS FLOOR - TYPE
AFF ABOVE FINISH FLOOR
ALT ALTERNATE
ALUM ALUMINUM
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
B/ BOTTOM OF
BD BOARD
BLDG BUILDING
BLKG BLOCKING
BM BEAM
BOS BOTTOM OF STEEL
CCS CLEANROOM CEILING SYSTEM
CF CUBIC FEET
CG-(#) CORNER GUARD - TYPE
CHK CHECKERED
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CLG CEILING
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONF CONFERENCE
CONT CONTINUOUS
COORD COORDINATE
CPT-(#) CARPET - TYPE
CR CARD READER
CR-(#) CRASH RAIL - TYPE
CRC CHEMICAL RESISTANT COATING
CS CONCRETE SEALER
CT-(#) CERAMIC TILE - TYPE
CTR CENTER
CWS-(#) CLEAN ROOM WALL SYSTEM - TYPE
DF DRINKING FOUNTAIN
DIA DIAMETER
DIM DIMENSION
DN DOWN
DR DOOR
DRB DESIGN REVISION BULLETIN
DTL DETAIL
DWG DRAWINGS
(E) EXISTING
EA EACH
CONTROL
ROOM
ADMINISTRATION
N
50' - 0"
50' - 0"
CONTROL ROOM EGRESS
THRU ADJOINING ADMIN
SPACE (1996 OSSC 1003.5,
1017.4).
SEPARATION; DISPERSAL
AREA REQUIREMENT
(1996 OSSC SECTION
1021)
DISPERSAL AREA
(1996 OSSC SECTION 1021)
TRAVEL DISTANCE 108'-0"
GYM
OUTDOOR
RECREATION
SUPPORT
SERVICES
B
SALLY
PORT
E-2
A-3
B
STATE HOUSING
UNIT
I-3
STATE HOUSING
UNIT
I-3
STATE HOUSING
UNIT
I-3
STATE HOUSING
UNIT
I-3
STATE HOUSING
UNIT
I-3
SALLY
PORT
PUBLIC WAY
SIDEWALK
P R
O P
E R
T Y
L
IN
E
NOTE F1
N O
T E
G
PROPERTY LINE
NOTE G4
P R
O P
E R
T Y
L
IN
E
P R
O P
E R
T Y
L
IN
E
NOTE G4
AREA OCCUPANCY LEGEND
OCCUPANCY CLASSIFICATION: A-3
OCCUPANCY CLASSIFICATION: E-2
OCCUPANCY CLASSIFICATION: B
OCCUPANCY CLASSIFICATION: I-3
SMOKE CONTROL ZONE
FIRE SEPARATION WALLS
1 HOUR OCCUPANCY SEPARATION WALL
2 HOUR OCCUPANCY SEPARATION WALL
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:13 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
M K
M K
J B
J B
OYA-002
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E C
O D
E P
L A
N
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 1" = 20'-0"
1 CODE ANALYSIS
SCOPE
OF
WORK
BUILDING CODE ANALYSIS JOSEPINE COUNTY FACILITY / GRANTS PASS, OREGON
(BASED ON STATE OF OREGON STRUCTURAL SPECIALTY CODE, 1994 EDITION
A. OCCUPANCY CLASSIFICATION
SPACE CLASSIFICATION ACTUAL AREA % TOTAL AREA ALLOWABLE AREA
GYMNASIUM A-3 3965 S.F 12% 4914 S.F
VACATIONAL EDUC, E-2 1790 S.F 5% 3240 S.F
NON-DETENTION 8770 S.F 26% UNLIMITED
AREAS
DETENTION HOUSING I-3 28,130 S.F 57% 52548 S.F
TOTAL 42,855 S.F 100%
B. CONSTRUCTION LIMITATIONS
OCCUPANCY CONST. TYPE MAX. AREA ALLOWABLE INCREASES MAX. HEIGHT
A-3 II - N 9,100 S.F 54,600 1 STORY
E-2 II - N 13,500 S.F 81,000 1 STORY
B II - N 12,000 S.F UNLIMITED 2 STORY
I-3 I or II F.R 15,100 S.F 90,600 2 STORY
C. BUILDING AREA INCREASES (SECTION 505)
1. SEPARATION ON ALL SIDES - 100 % INCREASE.
2. UNLIMITED INCREASE FOR 1-STORY, B OCCUPANCY, FULLY SPRINKLERED.
3. AUTOMATIC SPRINKLER SYSTEM - 200 % INCREASE.
D. OCCUPANCY REQUIREMENTS
1. GROUP I-3 SHALL BE HOUSED IN TYPE I OR TYPE II F.R CONSTRUCTION.
E. OCCUPANCY SPEARATION ( TABLE 3-B)
1. A-3 / B-N
2. A-3 / 1-3, 2-HR
3. B / I-3, 2HR
4. B / E-2, 1HR
F. EXTERIOR WALL REQUIREMENTS (TABLE 5A)
1. A-3 N.R., N.C. GREATER THAN 20' FROM PROPERTY LINE
2. E-2 N.R., N.C. GREATER THAN 10' FROM PROPERTY LINE
3. B N.R., N.C. GREATER THAN 20' FROM PROPERTY LINE.
4. I-3 BEARING WALL: 4-HR / N.C.
NON-BEARING WALLS: N.R / N.C. GREATER THAN 40' FROM PROPERTY LINE.
G. EXTERIOR WALL OPENING REQUIREMENTS ( TABLE 5A)
1. A-3 N.R. GREATER THAN 10' FROM PROPERTY LINE.
2. E-2 N.R. GREATER THAN 10' FROM PROPERTY LINE.
3. B N.R. GREATER THAN 10' FROM PROPERTY LINE.
4. I-3 N.R. GREATER THAN 20' FROM PROPERTY LINE.
2HR
H
R
H
R
2HR
DN
CONTROL
ROOM
EXISTING
HOUSING
UNIT
NOT PART OF
PROJECT
SCOPE
EXISTING
HOUSING
UNIT
NOT PART OF
PROJECT
SCOPE
EXISTING
GYM
NOT PART OF
PROJECT
SCOPE
EXISTING ADMINISTRATION
BUILDING
N
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:14 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
D e s ig n e r
J A
D A
M S
C h e c k e r
A p p ro v e r
OYA-100
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E F
IR
S
T F
L O
O R
P L
A N
O V
E R
A L
L
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
SOW
DN
CONTROL ROOM
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(D) VINYL
FLOOR TILE
(D) OBSERVATION WINDOWS AND
PORTION OF THE WALL BELOW.
REFER TO ELEVATIONS FOR MORE
INFORMATION
(D) RAISED ACCESS FLOOR PANELS,
SEE NEW SCOPE FOR REUSE OF
EXISTING PEDESTALS /
COMPONENTS WHERE POSSIBLE
(D) EXISTING CMU WALL TO
ACCOMMODATE FOR NEW
DOOR OPENING. SEE NEW
FLOOR PLAN AND DOOR
SCHEDULE FOR DOOR SIZE.
(D) EXISTING FURNITURE,
CABINETS, RACKS, SHELVES.
COORDINATE DISPOSITION WITH
OWNER
(D) VCT
(D) PANELS. (N) FINISH
PANELS TO BE INSTALED
ON (E) STEPS IF POSSIBLE
(D) EXISTING HANDRAIL
(D) EXISTING DOOR AND
WINDOW. INFILL TO MATCH
ADJACENT SURFACES. REFER
TO ELEVATION VIEW FOR
MORE INFORMATION
RESTROOM
OYA-200 4
(D) SHELVES
OYA-200
OYA-600
(E) GYPSUM
CEILING TO
REMAIN. PATCH
AND REPAIR IF
NECESSARY
(D) GYPSUM SOFFIT
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(D) ACT, LIGHTS
FIXTURES, SMOKE
DETECTORS,
SENSORS AND
CEILING GRIDS.
(E) SPRINKLER.
REFER TO MEP
DRAWINGS FOR
MORE INFORMATION
(E) DIFFUSER.
REFER TO MEP
DRAWINGS FOR
MORE INFORMATION
(D) ALL EXISTING LIGHT
FIXTURES. REFER TO MEP
DARWINGS FOR MORE
INFORMATION
(D) RETURN GRILLE.
REFER TO MEP
DRAWINGS FOR
MORE INFORMATION
(E) SPRINKLER.
REFER TO MEP
DRAWINGS FOR
MORE INFORMATION
(D) ALL
EXISTING
LIGHT
FIXTURES.
REFER TO
MEP
DARWINGS
FOR MORE
INFORMATION
(D) ALL
EXISTING
LIGHT
FIXTURES.
REFER TO
MEP
DARWINGS
FOR MORE
INFORMATION
(E) SPRINKLER.
REFER TO MEP
DRAWINGS FOR
MORE INFORMATION
FINISH FLOOR
0' - 0"
DEMO EXISTING
DOOR WINDOW AND
FRAMES. INFILL WITH
CMU BLOCK. FINISH
TO MATCH ADJACENT
SURFACES ON BOTH
SIDES
EXISTING WINDOW
AND FRAME TO
REMAIN
EXISTING WALL TO
REMAIN
VIF
V
IF
FINISH FLOOR
0' - 0"
RAISED ACCES FLOOR
2' - 8"
DEMO EXISTING CMU
WALL TO
ACCOMMODATE FOR
NEW DOOR OPENING.
REFER TO DOOR
SCHEDULE FOR
DOOR SIZE
PATCH/ INFILL
OPENING
EDGES WITH
MORTAR/GROUT
AS NECESSARY
DEMO
EXISTING
HANDRAIL
EXISTING PEDESTALS
TO REMAIN
EXISTING
CMU WALL
(D) EXISTING PANELS.
PROVIDE NEW.
REFER TO FINISH
SCHEDULE
APPROX.
36"
V
IF
WT5X11
REFER TO DEMO
NOTES AND LINTEL
DETAIL ON SHEET
OYA-600 FOR MORE
INFORMATION
BOLTS SPACED AT 8"
TEMPORARY SHORING.
SEE DETAIL 10/ OYA-600
2 BOLTS EA. SIDE IN
CONTINOUS CMU
MIN. 4"
6"
FINISH FLOOR
0' - 0"
RAISED ACCES FLOOR
2' - 8"
NOTE : REFER TO
DEMO NOTES AND
DETAILS ON SHEET
OYA-600 FOR MORE
INFORMATION
(D) EXISTING
WINDOW.
OPENING
LOWERED TO
JUST ABOVE RAF
DEMO PART OF EXISTING
CMU WALL TO
ACCOMMODATE FOR NEW
WINDOW. REFER TO
WINDOW SCHEDULE FOR
SIZE.
(E) CMU WALL
PATCH/ INFILL
OPENING
EDGES WITH
MORTAR/GROUT
AS NECESSARY
EXISTING EXISTING
V
IF
NOTE: SHORING COULD BE 2 CHANNELS
(C6X8.2) SANDWITCHING THE WALL.
SEQUENCE:
1. DRILL HOLES THRU CMU WALL
2. THRU-BOLT AND ATTACH CHANNELS,
EXTENDING 6-8" PAST AREA BEING DEMO-ED
3. DEMO WALL AS SHOWN IN HATCHED AREA
4. INSTALL NEW CHANNEL
5. INFILL WITH BLOCK, RE-GROUT ALL JOINTS
6. REMOVE CHANNELS AND BOLTS
7. PATCH/PAINT WALL TO CONCEAL HOLES
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:14 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
D e s ig n e r
J A
D A
M S
C h e c k e r
A p p ro v e r
OYA-200
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E D
E M
O L
IT
IO
N F
L O
O R
P L
A N
C O
N T
R O
L R
O O
M
- 1/2" = 1'-0"
1 DEMOLITION FLOOR PLAN - CONTROL ROOM
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 1/2" = 1'-0"
2 DEMOLITION REFLECTED CEILING PLAN - CONTROL ROOM
DEMO GENERAL NOTES:
- 1/2" = 1'-0"
4 DEMO EXISTING COURTYARD DOOR
- 1/2" = 1'-0"
5 DEMO NEW DOOR OPENING
- 1/2" = 1'-0"
6 DEMO NEW WINDOW OPENING
1. UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR IN THE
SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY.
2. BEFORE ANY DEMOLITION IS TO BE PERFORMED IN THE AREA OF
WORK, A PROTECTIVE BARRIER WILL HAVE TO BE IN PLACE TO
PROTECT THE WORK AREA FROM THE ADMINISTRATION AREA
SUCH AS A POLYETHYLENE FILM SHEETING.
3. REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION AND
ELECTRICAL DEMOLITION DRAWINGS FOR EXTENT OF
DEMOLITION OF MECHANICAL, PLUMBING, FIRE PROTECTION AND
ELECTRICAL ITEMS.
4. REMOVE AND DISPOSE OF ALL EXISTING EQUIPMENT AS
INDICATED ON THE DRAWINGS AS REQUIRED. EQUIPMENT
DESIGNATED FOR REUSE IS TO BE REMOVED AND STORED PER
OWNER/ CONSTRUCTION MANAGER DIRECTION.
5. DEMOLITION CONTRACTOR TO REVIEW NEW WORK
CONSTRUCTION DOCUMENTS FOR SCOPE, INTENT AND
COORDINATION WITH DEMOLITION.
6. REVIEW AND VERIFY PATH FOR REMOVAL OF TRASH/ DEBRIS
FROM PROJECT LOCATION WITH CONSTRUCTION MANAGER
PRIOR TO BEGINNING WORK.
7. DEMOLITION CONTRACTOR TO REPORT ANY FIELD CONDITIONS
THAT VARY FROM THOSE INDICATED ON THE DOCUMENTS.
8. DEMOLITION CONTRACTOR TO ADVISE CONSTRUCTION
MANAGER OF PARTITIONS OR WALLS REMAINING THAT HAVE
BEEN WEAKENED AFTER DEMOLITION AND ARE UNSAFE OR
UNSALVAGEABLE.
9. DEMOLITION CONTRACTOR TO INDICATE ANY ELECTRICAL RISER
OR PLUMBING RISER UNCOVERED WITHIN A DEMOLISHED
PARTITION. INCLUDES MECHANICAL DUCT SHAFTS NOT
INDICATED ON DOCUMENTS.
10. DEMOLITION CONTRACTOR TO SAFELY SECURE ANY AND ALL
PIPING, WIRING, CABLES OR DEVICES THAT ARE NOT
SCHEDULED FOR DEMOLITION AND WHERE SECURED BY ITEMS
(PARTITIONS) THAT HAVE BEEN OR ARE SCHEDULED FOR
DEMOLITION.
11. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR STRUCTURAL
INTEGRITY OF EXISTING BUILDING WHERE PART OR PORTIONS
OF STRUCTURE/WALLS HAVE BEEN REMOVED.
12. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PROTECTING
ALL STRUCTURE, WALLS, DOORS, MEP ITEMS, ETC. THAT ARE
REQUIRED TO REMAIN.
13. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO: WALLS,
FLOORS, MECHANICAL CONSTRUCTION, EXISTING
CONSTRUCTION TO REMAIN, EXISTING CONSTRUCTION TO BE
DEMOLISHED.
14. DEMOLITION CONTRACTOR TO VERIFY WITH OWNER AND/ OR
CONSTRUCTION MANAGER THOSE ITEMS THAT ARE TO BE
SALVAGED PER OWNER'S INSTRUCTIONS PRIOR TO BEGINNING
WORK.
15. COORDINATE WITH CONSTRUCTION MANAGER FOR TEMPORARY
PARTITIONS AS REQUIRED BY DEMOLITION WORK.
15. MARK THE OPENING SIZE FOR THE DOOR / WINDOWON BOTH
SIDES OF THE WALL. REFER TO SCHEDULE FOR DOOR/WINDOW
SIZE.
16. SAW CUT USING MASONRY CIRCULAR SAW BLADE. OPENING
SHOULD BE TWO INCHES WIDER THAN THE DOOR
FRAME, AND ABOUT AN INCH TALLER IN HEIGHT. ADD
ANOTHER SET OF MARKS ACROSS THE TOP OF THE
FRAME TO REPRESENT A STEEL LINTEL THAT WILL
SUPPORT THE LOAD ABOVE THE DOOR. THE LINTEL
SHOULD BE CENTERED OVER THE DOOR. IT SHOULD
ALSO EXTEND 6 INCHES PAST THE DOOR FRAME ON
EITHER SIDE. INFILL EACH SIDE OF THE OPENING BELOW LINTEL.
17. COORDINATE STORAGE OR DISPOSAL LOCATION WITH
CONSTRUCTION SUPERINTENDENT.
18. FOR MORE INFORMATION REFER TO SPECIFICATION 02 41 19
SELECTIVE DEMOLITION.
DN DN
296 SF
CONTROL ROOM
OYA-500
OYA-5001
OYA-500
36 SF
RESTROOM
(N) LOWER
WINDOWS, PROVIDE
(N) ONE-WAY FILM
AND BLINDS.
(N) PEGBOARD
FOR SECURITY
EQUP.
(R) DOOR
RELEASE BUTTON
(N) 3'-0" HIGH
COUNTERTOP - COUNTER
SPACE TO ACCOMODATE
MISC. EQUIPMENT
INCLUDING BUT NOT
LIMITED TO PRINTER, RADIO
CHARGING, ETC
(N) STORAGE
/ CUBBY
CABINET
(E) ELEC
PANELS
(N) FLOOR FINISH ON
RAISED ACCESS FLOOR
SYSTEM, REFURBISH
EXISTING TILES IF
AVAILABLE (N) 24" H X 36" W
WHITEBOARD
(N) DESK / CHAIR
WITH IT RACK UNDER
TO ACCOMODATE (4)
CPU + POSSIBLE
EXPANSION
(N) BUILT-IN CORNER
CASEWORK CABINET
TO ACCOMODATE
MISC. STORAGE
INCLUDING BUT NOT
LIMITED TO BINDERS,
OFFICE SUPPLIES,
RADIO CHARGER,
SUPPLIES, ETC. SEE
SHEET OYA-600 FOR
MORE INFORMATION
(E) PHONE
(E) TRANSACTION
DRAWER, (N)
CUSTOM CASEWORK
BUILT TO FIT. SEE
SHEET OYA-302 FOR
MORE INFO.
(N) DOOR TO ADJACENT
ADMINISTRATION SPACE
MANUALLY AND
ELECTRONICALLY KEYD
WITH DOOR POSITION
MONITORING. REFER TO
SHEET OYA-700 FOR MORE
INFORMATION.
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(N) BASE CABINETS -
CABINETS TO ACCOMODATE
MISC. STORAGE INCLUDING
BUT NOT LIMITED TO
BINDERS, OFFICE SUPPLIES,
BREAK AREA SUPPLIES,
ETC. SEE SHEET OYA-302
FOR MORE INFORMATION
(N) ELECTRIC
MOTOR SUN
SHADE AT (E)
WINDOW
(N) WALL MOUNTED
WASTE BASKET
(N) TOILET SEAT
COVER
DISPENSER
(N) GLOVE BOX
HOLDER - 5 BOX
CAPACITY
PAPER TOWEL
DISPENSER (OFOI)
SOAP DISPENSER
(OFOI)
TOILET PAPER DISPENSER
(OFOI)
(E) DOOR AND
WINDOW TO BE
REMOVED. INFILL
WITH CMU
BLOCK. FINISH TO
MATCH
ADJACENT
SURFACES
SECOND WORKSTATION
WITH (N) FIXED DESK AND
CHAIR
(N) SMALL KITCHEN SINK
PLUMBING CONNECTIONS
THROUGH ADJACENT
TOILET ROOM CHASE
(N) INSTANT HOT WATER
DISPENSER
(R) RADIO
(N) KEY
BOX
(E) UNDER COUNTER
REFRIGERATOR
(N) COFFEE MAKER
(N) STAIR
PANELS
(E) RAILING
TO REMAIN
(N) VCT
(N) VCT
C O
U R
T Y
A R
D N
O T
P A
R T
O F
P R
O J E
C T
O
P E
101A
102A
01 01
OYA-500
(N) UPPER CABINETS TO
ACCOMODATE MISC.
STORAGE INCLUDING
PERSONAL BELONGINGS.
REFER TO SHEET OYA-302
FOR MORE INFORMATION
FINISH PLAN GENERAL NOTES
A. ALL FLOORING TO EXTEND UNDER NEW MILLWORK, SHELVING AND EQUIPMENT.
B. FLOOR MATERIAL TRANSITIONS SHALL OCCUR UNDER THE CENTERLINE OF DOOR IN CLOSED POSITION.
C. NEW BASE THROUGHOUT SHALL BE RB1, UNO.
D. GWB CONSTRUCTION THROUGHOUT SHALL BE PT1 AND PT2 FOR RESTROOM, UNO. SEE SPEC 09 91 26 FOR MORE
INFORMATION
E. CLOSETS SHALL BE FINISHED TO MATCH ADJACENT SPACE, UNO.
F. GWB CEILINGS AND SOFFITS THROUGHOUT SHALL BE PAINTED PT1, UNO. .
G. DOORS, DOOR/ WINDOW FRAMES SHALL BE PAINTED IN SEMI-GLOSS FINISH. UNO. SEE SPEC 09 91 26 FOR MORE
INFORMATION
H. SEAMS IN RESILIENT BASE AT OUTSIDE CORNERS ARE NOT PERMITTED. ALL RESILIENT BASE TO BE PURCHASED IN 100'
ROLLED STOCK, NOT 48" INDIVIDUAL LENGTHS.
I. PROVIDE APPROPRIATE METAL TRANSITION STRIPS CENTERLINE AT EVERY FLOORING TRANSITION, UNLESS OTHERWISE
NOTED.
J. COORDINATE FLOORING INSTALLATION WITH ELECTRICAL DRAWINGS FOR ANY PROPOSED FLOOR POWER / DATA
RECEPTACLES. PATCH FLOOR SLAB AND FIT FLOOR FINISHES AROUND OUTLETS AS REQUIRED.
K. ALL GWB FINISH LEVELS AS INDICATED BY MANUFACTURER OF WALL-APPLIED PRODUCTS INCLUDING MARKERBOARDS, MARKERBOARD PAINTS, WALLCOVERING, AND TILE.
L. AT SOLID SURFACE SURFACES, ALL SEAMS TO BE FILLED W/ MANUFACTURER'S JOINT ADHESIVE. TO BE SANDED AND
BUFFED SMOOTH - NO VISIBLE SEAM, TYP
M. REFER TO SPECIFICATION 09 69 00 ACCESS FLOORING. FOR MORE INFORMATION.
CEILING
WALL
BASE
FLOOR
FINISH SYMBOL LEGEND:
OYA-500
OYA-5001
OYA-500
296 SF
CONTROL ROOM
36 SF
RESTROOM
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(N) VCT
101A
102A
01 01
OYA-500
PT2
RB1
VCT1
EXISTING
PT1
RB1
AFP1/VCT1
ACT1
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:15 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
J A
M
K J A
M
K J B
J B
OYA-300
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E F
IR
S
T F
L O
O R
P L
A N
C O
N T
R O
L R
O O
M
- 1/2" = 1'-0"
1 FLOOR PLAN - CONTROL ROOM
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 1/2" = 1'-0"
4 FLOOR PLAN -CONTROL ROOM FINISH PLAN
SUSPENDED ACOUSTIC
CEILING GRID
HANGER WIRE ANCHORED
TO STRUCTURE ABOVE
ACOUSTICAL CEILING TILE
CEILING GRID EDGE ANGLE
STABILIZER BAR, OR
OTHER SUITABLE
SYSTEM, TO KEEP
PERIMETER
COMPONENTS FROM
SPREADING
FASTENER, TYP
AT INSULATED METAL WALL
PANELS USE FASTENERS
RECOMMENDED BY IMP
CONT. BACKING
SEE PLAN FOR WALL TYPE
296 SF
CONTROL ROOM
38 SF
RESTROOM
(E) GYPSUM
CEILING TO
REMAIN. PATCH
AND REPAIR IF
NECESSARY
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(N) ACOUSTIC CEILING
TILES AND GRIDS.
REFER TO FINISH
SCHEDULE FOR MORE
INFORMATION
AFF
ACT 1
10'-8" A.F.F
(N) DIMMABLE LIGHT
FIXTURE. REFER TO
ELECTRICAL
DRAWINGS FOR MORE
INFORMATION
(E) HVAC SYSTEM.
PROVIDE NEW GRILLE.
RELOCATE IF
NECESSARY. REFER
TO MECHANICAL
DRAWINGS FOR MORE
INFORMATION
(E) SPRINKLER.
RELOCATE IF
NECESSARY. REFER
TO MEP DRAWINGS
FOR MORE
INFORMATION
(E) HVAC SYSTEM.
PROVIDE NEW GRILLE.
RELOCATE IF
NECESSARY. REFER
TO MECHANICAL
DRAWINGS FOR MORE
INFORMATION
(E) SPRINKLER.
RELOCATE IF
NECESSARY. REFER
TO MEP DRAWINGS
FOR MORE
INFORMATION
(N) DIMMABLE LIGHT
FIXTURE. REFER TO
ELECTRICAL
DRAWINGS FOR MORE
INFORMATION
(N) DIMMABLE LIGHT
FIXTURE. REFER TO
ELECTRICAL
DRAWINGS FOR MORE
INFORMATION
(E) SPRINKLER.
RELOCATE IF
NECESSARY. REFER
TO MEP DRAWINGS
FOR MORE
INFORMATION
(N) DIMMABLE LIGHT
FIXTURE. REFER TO
ELECTRICAL
DRAWINGS FOR MORE
INFORMATION
(N) ACOUSTIC CEILING
TILES AND GRIDS.
REFER TO FINISH
SCHEDULE FOR MORE
INFORMATION
EQEQ
E Q
E Q
16' - 0"
A. PROVIDE GYPSUM HEADERS ABOVE DEMOUNTABLE WALLS TO DECK, UNLESS
OTHERWISE NOTED.
B. LIGHT FIXTURE LOCATION TAKES PRECEDENCE OVER THE LOCATION OF EVERY OTHER
CEILING DEVICE OR ABOVE CEILING ELEMENT. FIXTURE MUST BE INSTALLAED WHERE
INDICATED AND DIMENSIONED.
C. FOR ALL NEW NEW CONTINOUS GWB CEILING: PROVIDE 5/8" GWB ON METAL FRAMING
SECURED TO SLAB ABOVE. FINISH HEIGHT AS DESIGNATED. PROVIDE ADDITIONAL
FRAMING FOR LIGHT FIXTURES AND OTHER ASSOCIATED CEILING DEVICES. RETURN
GWB TO 6" ABOVE FINISHED CEILING.
D. CEILINGS TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS'
SPECIFICATIONS, LOCAL BUILDING CODES AND ALL OTHER APPLICABLE CODES.
PROVIDE LATERAL BRACING AS REQUIRED. FOR MORE INFORMATION SEE
SPECIFICATION 09 51 13 ACOUSTICAL PANEL CEILINGS.
E. VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CLEARANCES TO ASSURE FINISHED
CEILING HEIGHTS CALLED OUT ON ARCHITECT DOCUMENTS. ANY DISCREPANCIES
SHALL BE BROUGHT TO ARCHITECT'S ATTENTION IMMEDIATELY, PRIOR TO
COMMENCEMENT OF WORK.
F. ANY CONFLICTS OR DISCREPANCIES AMONG FIXTURES, FIRE AND SMOKE DETECTION
DEVICES, HVAC OR OTHER CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF
ARCHITECT FOR CLARIFICATION.
G. COORDINATE REQUIRED ACCESS PANELS AT NEW GWB CEILINGS WITH ARCHITECT
PRIOR TO INSTALLATION.
H. ALL DIMENSIONS ARE TO CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE.
I. ALL CEILING GRIDS TO BE CENTERED IN SPACES WITH EQUAL TILES AT OPPOSITE SIDES
AS SHOWN UNLESS NOTED OTHERWISE.
J. ALL CEILING MOUNTED FIXTURES TO BE CENTERED ON LAY-IN PANELS IN SUSPENDED
CEILING AREAS AS SHOWN, UNLESS NOTED OTHERWISE.
K. PROVIDE ADDITIONAL FIRE-RESISTANT BLOCKING AND/OR ANCHORING ABOVE CEILINGS
AS REQUIRED FOR SUPPORT OF LIGHT FIXTURES.
L. ALL EXPOSED WIRING, CONDUIT, AND CABLES, TO BE NEATLY ARRANGED IN
COORDINATION WITH CEILIGN LAYOUT. NO 'SAGGING' WIRES OR CABLES IS
ACCEPTABLE.
M. REFER TO ELECTRICAL E-SERIES DRAWINGS FOR EMERGENCY LIGHTING LOCATIONS /
LAYOUT.
N. NOTIFY DESIGNER/ARCHITECT OF EXISTING ELECTRICAL CONFLICTS THAT MAY
INTERFERE WITH NEW LIGHTING LAYOUT.
O. SPRINKLER HEADS, HVAC DIFFUSER/RETURN GRILES TO BE RELOCATED IF NECESSARY.
REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.
REFLECTED CEILING PLAN GENERAL NOTES
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:15 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
D e s ig n e r
J A
D A
M S
C h e c k e r
A p p ro v e r
OYA-301
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E R
E F
L E
C T
E D
C E
IL
IN
G P
L A
N C
O N
T R
O L
R O
O M
- 1/2" = 1'-0"
1 REFLECTED CEILING PLAN - CONTROL ROOM
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 3" = 1'-0"
3 ACT PERIMETER @ INT WALL, TYP.
DNDN
CONTROL ROOM
36 SF
RESTROOM
(N) PEGBOARD
FOR SECURITY
EQUP. TO FIT
(R) DOOR
RELEASE BUTTON
(N) STORAGE
/ CUBBY
CABINET
(E) ELEC
PANELS
(N) 24" H X 36" W
WHITEBOARD
(N) DESK / CHAIR
WITH IT RACK UNDER
TO ACCOMODATE (4)
CPU + POSSIBLE
EXPANSION
(E) PHONE
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(N) ELECTRIC
MOTOR SUN
SHADE AT (E)
WINDOW
PAPER TOWEL
DISPENSER (OFOI)
SOAP DISPENSER
(OFOI)
TOILET PAPER DISPENSER
(OFOI)
SECOND WORKSTATION
WITH (N) FIXED DESK AND
CHAIR
(R) RADIO
(N) KEY
BOX
(E) UNDER COUNTER
REFRIGERATOR
C O
U R
T Y
A R
D N
O T
P A
R T
O F
P R
O J E
O
P E
101A
102A
01 01
(N) ELECTRIC
MOTOR SUN
SHADE AT (E)
WINDOW
E07
E07
E07
E07
E04
E04
E04
E03
E03
E03
E01
E02
E09
E10
E05
E08
E02
T01
T03
T02
E11
E06
E04
OYA-500
296 SF
CONTROL ROOM
36 SF
RESTROOM
(N) 3'-0" HIGH
COUNTERTOP - COUNTER
SPACE TO ACCOMODATE
MISC. EQUIPMENT
INCLUDING BUT NOT
LIMITED TO PRINTER, RADIO
CHARGING, ETC
(N) STORAGE / CUBBY
CABINET. SEE
RESTROOM
ELEVATION ON
SHEET OYA-500
(E) ELEC
PANELS
(N) 24" H X 36" W
WHITEBOARD
(N) BUILT-IN CORNER
CASEWORK CABINET TO
ACCOMODATE MISC.
STORAGE INCLUDING BUT
NOT LIMITED TO BINDERS,
OFFICE SUPPLIES, RADIO
CHARGER, SUPPLIES, ETC.
SEE SHEET OYA-600 FOR
MORE INFORMATION
EXISTING HOUSING UNIT
NOT PART OF PROJECT
SCOPE
EXISTING
ADMINISTRATION
BUILDING
NOT PART OF PROJECT
SCOPE
(N) BASE CABINETS TO
ACCOMODATE MISC.
STORAGE INCLUDING BUT
NOT LIMITED TO BINDERS,
OFFICE SUPPLIES, BREAK
AREA SUPPLIES, ETC. SEE
SHEET OYA-600 FOR MORE
INFORMATION
C O
U R
T Y
A R
D N
O T
P A
R T
O F
P R
O J E
O
P E
101A
102A
01 01
(N) POWER /
DATA OUTLET,
TYP.
(N) POWER
OUTLET, TYP.
(N) POWER /
DATA OUTLET,
TYP.
(N) SMALL KITCHEN SINK
PLUMBING CONNECTIONS
THROUGH ADJACENT
TOILET ROOM CHASE
(N) POWER
OUTLET, TYP.
2' - 1"
1' - 10"1' - 0"
5' - 11"
(N) POWER /
DATA OUTLET,
TYP.
(N) POWER
OUTLET, TYP.
(N) POWER
OUTLET, TYP.
2' - 0"
V
IF
VIF
(E) TRANSACTION
DRAWER, (N)
CUSTOM CASEWORK
BUILT TO FIT. SEE
SHEET OYA-600 FOR
MORE INFO.
OYA-600 8
OYA-600
OYA-6004
OYA-600
OYA-500
OYA-600 6
135.00°
.0
(N) UPPER CABINETS TO
ACCOMODATE MISC.
STORAGE INCLUDING
PERSONAL BELONGINGS.
SEE SHEET OYA-600 FOR
MORE INFORMATION
VIF
1. FURNITURE SHOWN FOR REFERENCE ONLY. COORDINATE LAYOUT WITH OWNER'S FURNITURE
PROVIDER. FOR MORE INFORMATION REFER TO SPEC 12 00 00.
2. REFER TO FURNITURE DOCUMENT / SPECIFICATIONS FOR ALL FURNITURE DESIGNATIONS AND
LOCATIONS.
3. CONTRACTOR RESPONSIBLE FOR COORDINATING WITH OWNER'S AV. CONTRACTOR AND
FURNITURE VENDOR TO COORDINATE LOCATIONS OF ELECTRICAL AND AV CONNECTIONS
REQUIRED TO BE INTEGRATED IN THE FURNITURE AND AT THE PARTITIONS.
4. LINES SHOWN HALF-TONE REPRESENT MILLWORK, CASEWORK, AND EQUIPMENT ITEMS THAT ARE INTENDED TO BE INCLUDED IN THE BASE BID CONTRACT. ITEMS SHOWN WITH SOLID LINES ARE
INTENDED AS PART OF THE FURNITURE CONTRACT.
5. DIMENSIONS FOR REFERENCE ONLY. ALL DIMENSIONS AND CONDITIONS TO BE REVIEWED ON SITE
PER BUILT CONSTRUCTION. REFER TO PARTITION PLANS FOR DIMENSIONAL LAYOUT.
FURNITURE PLAN GENERAL NOTES
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:15 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
J A
M
K J A
M
K J B
J B
OYA-302
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E E
N L A
R G
E D
F U
R N
IT
U
R E
P L
A N
E
Q U
IP
M
E N
T
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 1/2" = 1'-0"
1 FLOOR PLAN - ENLARGED EQUIPMENT PLAN
- 1/2" = 1'-0"
2 FLOOR PLAN - ENLARGED FURNITURE PLAN
E11 WHITE BOARD TBD TBD OFCI 1 24' X 36"
E10 PEGBOARD TBD TBD OFCI 1 TBD
FOR SECURITY EQUIPMENT.
COSTUM TO FIT.
E09
KEY BOX HOLDER 60-KEY HEVY
DUTY DIGITAL LOCK
ADIROFFICE 680-60-WHT OFCI 1 17" x 13" x 2 1/2"
E08 FIXED DESK TBD TBD OFCI 1 TBD
E07 WINDOW SHADES MECHO SHADE MECHO/7 OFCI VIF POWER ELECTRIC
E06 COFFEE MAKER TBD TBD OFCI PORTABLE
E05 HOT WATER DISPENSER INSINKERATOR H-HOT100100C-SS OFCI 1 TBD
E04 MONITOR TBD TBD OFCI 4 43"
MOUNTED ABOVE THE WINDOW.
FOLLOW MANUFACTURE
RECOMENDATION FOR MOUNTING
E03 CONSOLE MONITOR TBD TBD OFCI 4 24"
FOLLOW MANUFACTURER
RECOMENDATION FOR SIZES AND
MONITOR ARMS
E02 DESK CHAIR TBD TBD OFCI 2
E01
VISIONLINE 24/7 CONSOLE,
LARGE 89" W
MIDDLE ATLANTIC LH-VLCLHS OFCI 1 89" WIDTH
T03 GLOVE BOX GLOBAL INDUSTRIAL T9AB2222415 OFCI 1 3 3/4" x 16" x 10"
T02
TOILET SEAT COVER
DISPENSER
ASI T9AB201858 OFCI 1 2 5/8" x 15 3/4" x 11 1/4"
T01 WALL MOUNT TRASH CAN GLOBAL INDUSTRIAL T9A641438SS OFCI 1 7 1/2" x 15 1/4" x 24 1/4"
TAG TYPE MANUFACTURER MODEL PROVIDER QTY SIZE KEY NOTES
NEW EQUIPMENT LEGEND
RAISED ACCES FLOOR
2' - 8"
(N) BASE CABINETS -
CABINETS TO ACCOMODATE
MISC. STORAGE INCLUDING
BUT NOT LIMITED TO
BINDERS, OFFICE SUPPLIES,
BREAK AREA SUPPLIES, ETC
(E) WINDOWS
(N) COFFEE
MAKER
(N) HOT WATER
DISPENSER
(N) MINI FRIDGE
UNDER
CANTERTOP
SECOND
WORKSTATION WITH
(N) FIXED DESK AND
CHAIR
PT1
RB1
PT1
FINISH FLOOR
0' - 0"
RAISED ACCES FLOOR
2' - 8"
(N) FLAT SCREEN
MONITORS ON WALL
MOUNT ABOVE
WINDOW
(N) ACOUSTIC
CEILING @ 8'-0"
ABOVE RAF
(N) SECURITY
EQUIP. BOARD
(N) BUILT-IN CORNER
CASEWORK WITH
STORAGE BELOW. SEE
SHEET OYA-600 FOR
MORE INFORMATION
7' - 0"
(E) TRANSACTION
DRAWER, (N)
CUSTOM CASEWORK
BUILT TO FIT. SEE
DETAILS ON SHEET
OYA-600.
EXISITNG WALL TO REMAIN.
PATCH AND RAPAIR IF
NECESSARY
RB1
(N) HANDRAIL
PT1
EXISITNG
WINDOW FRAME
TO REMAIN
(E) WINDOW
PT1
(N) ELECTRIC
MOTOR SUN
SHADE AT (E)
WINDOW
RAISED ACCES FLOOR
2' - 8"
A V
G S
T A
N D
IN
G
E Y
E H
E
IG
H T
/2
S E
A T
E D
E Y
E H
E
IG
H T
/2
A V
G
.0
.0
A P
P R
O X
/8
.0
.0
(N) 24" H X 36" W
WHITEBOARD
(E) WINDOW
(N) DESK / CHAIR
WITH IT RACK UNDER
TO ACCOMODATE (4)
CPU + POSSIBLE
EXPANSION
3' - 8"
(N) WINDOWS WITH ONE-WAY
FILM AND BLINDS. SILL
LOWERED TO JUST ABOVE
RAF. REFER TO DETAIL SHEET
OYA-600 FOR MORE INFO.
3' - 8"
EQ EQ
(N) MONITORS.
FOLLOW MFR
RECOMENDATIONS
FOR MOUNTONG
AND BLOCKING
PT1
RB1
RB1
(R) FIRE
ALARM
(N) ELECTRIC
MOTOR SUN SHADE
AT (E) WINDOW
RAISED ACCES FLOOR
2' - 8"
(N) KEY BOX
(N) BASE CABINETS -
CABINETS TO ACCOMODATE
MISC. STORAGE INCLUDING
BUT NOT LIMITED TO
BINDERS, OFFICE SUPPLIES,
BREAK AREA SUPPLIES, ETC
(N) HOT WATEWR
DISPENSER
(E) MINI FRIDGE
(N) COFFE MAKER
(E) WALL TO
REMAIN
102A
PT1PT1
PT1
RB1
TALL
STORAGE
CABINET
OPEN
CUBBIES OR
PERSONAL
LOCKERS
RAISED ACCES FLOOR
2' - 8"
2' - 6"
1' - 6" 1' - 0"
E Q
E Q
E Q
(N) WALL MOUT
TRASH CAN.
REFER TO
SHEET OYA - 001
FOR MOUNTING
HEIGHTS
PT2
RB1
RAISED ACCES FLOOR
2' - 8"
(N) GLOW BOX.
REFER TO
SHEET OYA - 001
FOR MOUNTING
HEIGHTS
(N) TOILET SEAT
DISPENSER.
REFER TO
SHEET OYA - 001
FOR MOUNTING
HEIGHTS
(N) WALL MOUT
TRASH CAN
(E) MIRROR
PT2
RB1
FINISH FLOOR
0' - 0"
RAISED ACCES FLOOR
2' - 8"
(N) DOOR TO
ADMINISTRATION
BUILDING. REFER TO
DOOR SCHEDULE
FOR MORE
INFORMATION
(E) STAIRS TO
REMAIN. PROVIDE
NEW FINISH PANELS
IF NECESSARY AND
REUSE EXISTING
PEDESTALS
(N) NEW HANDRAIL
MOUNTED TO WALL
101A
PT1
RB1
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:16 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
J A
M
K J A
M
K J B
J B
OYA-500
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E
IN
T E
R
IO
R E
L E
V A
T
IO
N S
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 1/2" = 1'-0"
1 ELEVATION - CONTROL ROOM NORTH
- 1/2" = 1'-0"
2 ELEVATION - CONTROL ROOM SOUTH
- 1/2" = 1'-0"
3 ELEVATION - CONTROL ROOM EAST
- 1/2" = 1'-0"
4 ELEVATION - CONTROL ROOM WEST
- 1/2" = 1'-0"
5 RESTROOM WEST WALL
- 1/2" = 1'-0"
6 RESTROOM NORTH WALL
- 1/2" = 1'-0"
7 ELEVATION - CONTROL ROOM NEW ENTRY DOOR
REFER TO PLAN
FOR DOOR SWING
HOLLOW METAL DOOR
AND DOOR FRAME
REFER TO DOOR SCHEDULE
CONTINUOUS BEAD OF SEALANT
AND BACKER ROD, EACH SIDE, TYP.
EXISTING CMU WALL
SHIM AS NECESSARY
6"2
A T
J A
M B
A T
H E
A D
GALV METAL
DRIP EDGE
INTERIOR
EXTERIOR
STEEL LINTEL INVERTED 'T' TYPE
SHOWN, OTHER STEEL LINTELS ALSO
ACCEPTABLE
/4
/4
FILL SOLID WITH NON-SHRINK GROUT
CONTROL JOINT SEE SPECIFICATIONS
HOLLOW METAL DOOR
AND DOOR FRAME
REFER TO DOOR SCHEDULE
CONCRETE FLOOR SLAB
REFER TO FINISH SCHEDULE
ALUMINUM THRESHOLD SET IN SEALANT
PROVIDE CLOSURE AT ENDS, TYP.
CMU/CONCRETE WALL
BEYOND
INTERIOREXTERIOR
A
EXISTING CMU WALL.
INFILL WITH MORTAR
AS NECESSARY.
GLASS. REFER TO
WINDOW SCHEDULE.
V
IF
GLASS. REFER
TO WINDOW
SCHEDULE.
CONTINUOUS
BEAD OF SEALANT
AND BACKER ROD,
EACH SIDE, TYP.
CONTINUOUS BEAD OF
SEALANT AND BACKER
ROD, EACH SIDE, TYP.
SHIM AS NECESSARY
EXISTING
CMU WALL
EXTERIOR
EXTERIOR
CONTROL
ROOM
REMOVABLE 12 GA. 1-1/4"
ANGLE, STL. STOP,
SECURE TO FRAMES AS
SPECIFIED
1 1/4"0' - 2"
/2
HM FRAME FILL SOLID
WITH RIGID INSUL.,
PAINT; TYP. REFER TO
WINDOW SCHEDULE
VIF
/4
7 1/2"
CONTROL
ROOM
REMOVABLE 12 GA. 1-1/4"
ANGLE, STL. STOP,
SECURE TO FRAMES AS
SPECIFIED
B
HM FRAME FILL SOLID
WITH RIGID INSUL.,
PAINT; TYP. REFER TO
WINDOW SCHEDULE
SHIM AS NECESSARY
/4
3 1/4"
RAISED ACCES FLOOR
2' - 8"
(N) BASE CABINETS -
CABINETS TO
ACCOMODATE MISC.
STORAGE INCLUDING BUT
NOT LIMITED TO BINDERS,
OFFICE SUPPLIES, BREAK
AREA SUPPLIES, ETC
LT1
LT1
(N) BASE
CORNER
CABINET
WITH
SINK
SS1
36"
24"
/4
/2
36"
18" 15" 15" 15" 15" 15"
(N) UPPER CABINETS
TYP. PROVIDE KEYED
CAM LOCK ON ALL
WALL CABINETS EXEPT
CORNER CABINET.
CABINET TO
ACCOMODATE MISC.
PERSONAL BELONGINS
4" BAR HANDELS.
STAINLESS
STEEL FINISH
CAM LOCK
KEYED
(N)
UPPER
CORNER
CABINET
24"
12"
RAISED ACCES FLOOR
2' - 8"
SS1
LT1
3/4" END
PANEL, LT1
OPEN
(N) BASE CABINETS -
CABINETS TO ACCOMODATE
MISC. STORAGE INCLUDING
BUT NOT LIMITED TO
BINDERS, OFFICE SUPPLIES,
BREAK AREA SUPPLIES, ETC
23"
/4
15" 18" 24"
12"
36"
24"
3"
/2
21 1/2"
(N) UPPER CABINETS TYP.
PROVIDE KEYED CAM LOCK
ON ALL WALL CABINETS
EXEPT CORNER CABINET.
CABINETS TO ACCOMODATE
MISC. PERSONAL
BELONGINGS
(N) UPPER
CORNER CABINET
TYP.
CAM LOCK
KEYED
4" BAR HANDLES.
STAINLESS STEEL
FINISH.
RAISED ACCES FLOOR
2' - 8"
(N) BUILT-IN
CORNER
CASEWORK SS1
LT1
E Q
OPEN
SHELVES
6" DEEP 1' - 0"
/4
E Q
/4
3' - 2"
2' - 1"
/2
(N) CABINETS TO
ACCOMODATE MISC.
STORAGE INCLUDING
BUT NOT LIMITED TO
BINDERS, OFFICE
SUPPLIES, BREAK AREA
SUPPLIES, ETC
RAISED ACCES FLOOR
2' - 8"
OPEN
(N) BUILT-IN
CORNER
CASEWORK
SS1LT1
OPEN
SHELVES
1' - 10 1/2" 3' - 2"
3/4"
E Q
E Q
" 1
/4
6"
/2
/4
RAISED ACCES FLOOR
2' - 8"
(E) HANDRAIL
(E) TRANSACTION
DRAWER, (N)
CUSTOM CASEWORK
BUILT TO FIT
(E) WALL
/4
2' - 6"
SS1
LT1
/2
VIF
RAISED ACCES FLOOR
2' - 8"
SS1
LT1
(E)
TRANSACTION
DRAWER
V
IF
(E) WINDOW
(N) CUSTOM
CASEWORK BUILT TO
FIT
(E) CMU WALL
/2
2' - 0"
14"
3"21"
/4
THRU-BOLTS
SPACED AT 8"
TEMP.
CHANNELS
C6X8.2
1' - 4" 1' - 4"DOOR OPENING
CMU
Date:
Proj. No.:
D S
G N
D R
C H
K A
P V
D
A P
V D
B Y
R E
V
IS
IO
N
D A
T E
N O
PLOT DATE/TIME:
Drawing No.:
P ro je c t T it le
D ra w in g T it le
D
C
B
A
1 2 3 4 5 6
REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.
www.Jacobs.com
J a c o b s E n g in e e ri n g G ro u p I n c
A
L L R
IG
H
T S
R E
S E
R V
E D
12/10/2023
11/29/2023 9:10:16 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Roque_Valley_OYA-Control-Room-Upgrade-ARCH.rvt
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
D3482000
J A
M
K J A
M
K J B
J B
OYA-600
O R
E G
O N
Y O
U T
H A
U T
H O
R
IT
Y R
O G
U E
V A
L L E
Y F
A C
IL
IT
Y
ROGUE VALLEY FACILITY
2001 NE F ST
GRANTS PASS, OR 97526
PORTLAND OFFICE
PORTLAND, OR 97201
2020 SW 4TH AVE, SUITE 300
A R
C H
IT
E
C T
U R
E D
E T
A
IL
S
/1
/2
IS
S
U E
F O
R C
O N
S T
R U
C T
IO
N
- 1 1/2" = 1'-0"
1 HM DOOR DETAIL @ CMU WALL, TYP.
- 1 1/2" = 1'-0"
2 HM DOOR SILL @ CMU WALL SILL, TYP.
- 1 1/2" = 1'-0"
3 WINDOW JAMB & SILL, TYP.
- 1/2" = 1'-0"
4 BREAK AREA CABINETS NORTH VIEW
- 1/2" = 1'-0"
5 BREAK AREA CABINETS WEST VIEW
- 1/2" = 1'-0"
6 CORNER CASEWORK FRONT VIEW
- 1/2" = 1'-0"
7 CORNER CASEWORK SIDE VIEW
- 1/2" = 1'-0"
8 TRANSACTION DRAWER FRONT VIEW
- 1/2" = 1'-0"
9 TRANSACTION DRAWER SIDE VIEW
- 1" = 1'-0"
10 SHORING DETAIL
ADMINISTRATION OFFICE
CONTROL
ROOM
A
O U
S T
IC
A
L C
E
IL
IN
G
T
IL
E
G
R
ID
ACT 1
GRID
MANUFACTURER
MODEL
NUMBER / SIZE
COLOR
REMARKS
CLASSIFICATION
MANUFACTURER
STYLE NAME
NUMBER / SIZE
COLOR
AMSTRONG
CALLA
24" X 24"
BLACK
@ CONTROL ROOM
CLASS A
AMSTRONG
INTERLUDE XL
9/16"
BLACK
F L
O O
R
VCT1
AFP1
MANUFACTURER
MODEL
NUMBER / SIZE
COLOR
REMARKS
MANUFACTURER
MODEL
SIZE
TARKETT
12" X 12"
CORTINA GRANDE - BLACK & WHITE
@ RESTROOM / CONTROL ROOM
TATE
STONEWORKS DECORATIV CONCRETE
ACCESS FLOOR PANEL
24" X 24"
FINISH MIDNIGHT
R E
S
IL
IE
N
T B
A S
E
RB1
MANUFACTURER
MODEL
NUMBER / SIZE
COLOR
REMARKS
NOTES
FLEXCO
4"
BLACK
@ RESTROOM / CONTROL ROOM
RUBBER, STRAIGHT
P A
IN
T
PT1
MANUFACTURER
FINISH
NUMBER
COLOR
NOTES
SHERWIN WILLIAMS
SNOWBOUND
@ CONTROL ROOM
EGGSHELL
SW 7004
PT2
MANUFACTURER
FINISH
NUMBER
COLOR
NOTES
SHERWIN WILLIAMS
SNOWBOUND
@ RESTROOM
SATIN
SW 7004
PT3
MANUFACTURER
FINISH
NUMBER
COLOR
NOTES
SHERWIN WILLIAMS
MATCH WITH EXISTING HM FRAMES
@ HM FRAMES
SEMI - GLOSS
TBD
S O
L
ID
U R
F A
C E
SS1
MANUFACTURER
FINISH
SIZE
NOTES
CORIAN
1 1/4"
@ COUNTERTOP
SPARKLING GRANITA
R E
S
IL
IE
N
T B
A S
E
RB1
MANUFACTURER
MODEL
NUMBER / SIZE
COLOR
REMARKS
NOTES
FLEXCO
4"
BLACK
@ RESTROOM / CONTROL ROOM
RUBBER, STRAIGHT
W
IN
D O
W F
IL
M
WF1
MANUFACTURER
MODEL
NUMBER / SIZE
COLOR
NOTES
3M
@ CONTROL ROOM
PRIVACY FILM (ONE-WAY)
F
IN
IS
H
LT1
MANUFACTURER
MODEL
NUMBER / SIZE
COLOR
NOTES
FORMICA
@ CABINETS
FINISH OAK
1. VERIFY ALL EXISTING DOOR SIZES, DISCREPANCIES WITH SCHEDULE
SHOULD BE NOTED AND REVIEWED WITH ARCHITECT.
2. HARDWARE SCHEDULE HAS BEEN DEVELOPED FOR DESIGN INTENT ONLY.
HARDWARE PROVIDER IS RESPONSIBLE FOR VERIFYING THE FUNCTION AND
COMPATIBILITY OF ALL COMPONENTS.
3. UNLESS OTHERWISE NOTED, THE HEIGHT OF DOOR HARDWARE HANDSETS
ARE TO MATCH ADJACENT EXISTING HARDWARE.
4. DOOR HARDWARE TO BE COMPLETE IN ORDER TO FUNCTION AS
DESCRIBED IN THESE NOTES, SCHEDULES AND SPECIFICATIONS
5. PROVIDE ALL HARDWARE ACCESSORIES NOT LIMITED TO HINGES,
ASTRAGALS, BOLTS, AUTOMATIC BOLTS, FLUSH BOLTS, AUTOMATIC FLUSH
BOLTS, SMOKE SEALS, COORDINATORS, LOCK SETS, LATCHES, LEVERS
STRIKE PLATES, CLOSERS, KEYS CYLINDERS, STOPS, FLOOR AND WALL
STOPS, SILENCERS, BOTTOMS, SADDLES, TRIM, KICK PLATES, ETC. REFER
TO SPECIFICATIONS.
6. PROVIDE ELECTRIC CAPABILITY FOR DOOR CONTACTS, ACCESS CONTROL,
READERS, ELECTRIC HINGES AND ANY OTHER ELECTRIC REQUIREMENT TO
SATISFY THE FUNCTION OF THE DOORS AS DESCRIBED IN THESE NOTES,
SCHEDULES AND SPECIFICATIONS.
7. SECURITY INTEGRATOR TO INSTALL CARD READER HARDWARE. GC IS
RESPONSIBLE FOR COORDINATING AND INSTALLATION OF HARDWARE WITH
SECURITY AND ELECTRICAL REQUIREMENTS FOR DOORS. GC IS
RESPONSBILE FOR PROVIDING POWER & PATHWAYS AS NEEDED.
8. ALL DOORS AND FRAMES TO BE FACTORY PREPPED TO RECEIVE INTENDED
DOOR HARDWARE, RATED DOORS TO MAINTAIN FIRE RATING.
9. ARCHITECT IS NOT RESPONSIBLE FOR KEYING REQUIREMENTS. GC IS
RESPONSIBLE FOR PROCURING AND INSTALLING ALL CORES & LOCKSETS.
GC TO COORDINATE WITH OWNER'S PM AND BUILDING FACILITIES FOR
KEYING REQUIREMENTS.
10. LOCATION OF DOOR IS DETERMINED BY THE DOOR NUMBER, EXAMPLE:
101A (ROOM NUMBER- 101 DOOR- A).
11. SEE SPECIFICATION 08 34 60 DETENTION DOORS AND FRAMES, 08 71 00
DOOR HARDWARE, 08 80 00 GLAZING AND 08 51 00 METAL WINDOWS FOR
MORE INFORMATION.
WINDOW, DOOR & HARDWARE GENERAL NOTES:
ABS ABS PLASTIC
AL ALUMINIUM
(E) EXISTING
FGR FIRE RATED CERAMIC GLASS
FACT FACTORY FINISH
GL GLASS
HM HOLLOW METAL
MIN MINUTE
MATL MATERIAL
LSS LIFE SAFETY SYSTEM
NR NOT RATED
N/A NOT APPLICABLE
P PAINT
PT PAINTED FINISH
PR PAIR
(R) RELOCATED
SIM SIMILAR
STL STEEL
TEMP TEMPERED
SS STAINLESS STEEL (304 or 316? brushed finish?)
WD WOOD
WG WIRE GLASS
VN VENEER
DOOR SCHEDULE ABBREVIATIONS:
1. BY MANUFACTURER
2. PANIC HARDWARE
3. 90° SWING
4. 180° SWING
5. CARD READER
6. PROVIDE AUTOMATIC DOOR OPERATOR AND DOOR
ACTUATORS.
7. ELECTRIFIED HARDWARE.
8. CARD ACCESS CONTROLLED W/ADJACENT DOOR.
9. DOOR IS PART OF GLAZING ASSEMBLY. HARDWARE,
PULLS, AND HINGES PROVIDED BY GLASS VENDOR.
10. DOOR…
This is the start of the file's text. The full file is on GovTribe.