Attachment B - EASTERN OREGON_OYA_FULL SET.pdf

PDF 13 MB Posted

Attached to
Control Room Renovations (EOYCF, OCYCF, and RVYCF)
Solicitation number
S-DASOBO-00009651
Issued by
Hood River County, Jackson County, Linn County, Albany City, Oregon

About this file

This document appears to be Attachment B - EASTERN OREGON_OYA_FULL SET.pdf, which is related to a state and local contract opportunity for Control Room Renovations (EOYCF, OCYCF, and RVYCF) in the state of Oregon. The purpose of this Invitation to Bid (ITB) is to establish a contract to update control rooms at three youth correctional facilities located in Harney, Josephine, and Linn Counties, as well as the cities of Albany. The contract will cover renovations at the Eastern Oregon Youth Correctional Facility, Oak Creek Youth Correctional Facility, and Rogue Valley Youth Correctional Facility. No further details are provided regarding response dates, site visits, or award information.

The document does not contain any information about pricing terms, set asides, incumbents, funding requirements, or other salient details. It appears to be solely focused on the scope of work for the control room renovations across the three specified facilities in Oregon.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:02 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-000

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

C O

V E

R S

H E

E T

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

OREGON YOUTH AUTHORITY

REGIONAL FACILITIES

CONTROL ROOM UPGRADE

EASTERN OREGON YOUTH CORRECTIONAL FACILITY

DECEMBER 2023

JACOBS PROJECT NO. D3482000

SHEET LIST

DRAWING DRAWING TITLE DISCIPLINE REV DATE

OYA-000 COVER SHEET COVER SHEET 0 12/10/2022

OYA-001 LEGENDS & ABBREVIATIONS ARCHITECTURE 0 12/10/2022

OYA-002 CODE PLAN ARCHITECTURE 0 12/10/2022

OYA-100 FIRST FLOOR PLAN OVERALL ARCHITECTURE 0 12/10/2022

OYA-200 DEMOLITION PLAN ARCHITECTURE 0 12/10/2022

OYA-300 ENLARGED FLOOR PLAN & FINISH ARCHITECTURE 0 12/10/2022

OYA-301 ENLARGED CEILING PLAN ARCHITECTURE 0 12/10/2022

OYA-302 ENLARGED FURNITURE PLAN & EQUIPMENT ARCHITECTURE 0 12/10/2022

OYA-500 INTERIOR ELEVATIONS ARCHITECTURE 0 12/10/2022

OYA-600 DETAILS ARCHITECTURE 0 12/10/2022

OYA-700 DOOR AND ROOM SCHEDULES & FINISH LEGEND ARCHITECTURE 0 12/10/2022

PROJECT LOCATION

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

VICINITY MAP

OYA-E301 LIGHTING PLAN ELECTRICAL 0 12/10/2023

OYA-E302 POWER PLAN ELECTRICAL 0 12/10/2023

OYA-M100 FLOOR PLAN MECHANICAL 0 12/10/2023

OYA-ES0001 LEGEND ABBREVIATIONS & GENERAL NOTES SECURITY 0 12/10/2023

OYA-ES1000 SECURITY PLAN SECURITY 0 12/10/2023

OYA-ES4701A DOOR CONTROL LOOP TERM. WIRING - PANEL 1 SECURITY 0 12/10/2023

OYA-ES4701C DOOR CONTROL LOOP TERM. WIRING - PANEL 1 SECURITY 0 12/10/2023

OYA-ES4701E DOOR CONTROL LOOP TERM. WIRING - PANEL 1 SECURITY 0 12/10/2023

OYA-ES7201 SECURITY DOOR DETAILS SECURITY 0 12/10/2023

OYA-ES7210 SECURITY DETAILS SECURITY 0 12/10/2023

11/29/2023

H

S

VENT

INSULATION

GYPSUM BOARD

FINISHES

ACOUSTICAL TILE

BATT/LOOSE FILL

RIGID

WOOD

PLYWOOD

BLOCKING

ROUGH

STEEL

FINISH

MASONRY

METAL

ALUMINUM

SAND

BRICK OR CMU

EARTHWORKS

CONCRETE

MATERIAL LEGEND

CONCRETE

GRAVEL

EARTH

FURRING ZEE CHANNEL

SLOTTED CHANNEL FRAMING

CURTAIN WALL /

STORE FRONT

FIXED

SLIDING

WINDOW TYPES

ROUND CONCRETE COLUMN

STEEL DECKING

CONCRETE & STEEL DECKING

CONCRETE BEAM OR GIRDER

STEEL BEAM OR GIRDER

JOIST OR GIRDER(ELEVATION)

C - METAL STUD

SHAFTWALL STUD

FURRING HAT CHANNEL

METAL STUD RUNNER

STEEL ANGLE

STEEL CHANNEL

FIRE PROTECTION

SMOKE DETECTOR

HEAT DETECTOR

SPRINKLER

FIRE EXTINGUISHER

SPEAKER

CLOCK

MISC. ARCHITECTURAL

CORNER GUARD TUBE STEEL COLUMN

STEEL PIPE COLUMN

WIDE FLANGE COLUMN

SQUARE CONCRETE COLUMN

BUILDING SYSTEM LEGEND

STRUCTURAL

ARCHITECTURAL ABBREVIATIONS

ARROW AT ROOF PLANS

INDICATES SLOPE AND

DOWN DIRECTION

ARROW AT STAIR PLANS

INDICATES UP OR DOWN

DIRECTION

CONCRETE COLUMN WITH

EMBEDDED UNISTRUT

POWER AND

COMMUNICATIONS

PP

POWER POLE

CR

CARD READER

OVERHEAD COILING

SLIDING (BREAKAWAY)

SLIDING

SINGLE (TWO WAY)

DOUBLE (180 DEGREES)

DOUBLE (TWO WAY)

DOUBLE

SINGLE W/ SIDE LITE

SINGLE (180 DEGREES)

DOOR TYPES

SINGLE

CIP WATERSTOP

UP

DN

X"/X"

FE-XX FE- TYPE

GENERAL NOTES

A. THIS IS A STANDARD LEGEND SHEET WHICH CONTAINS INFORMATION THAT MAY

NOT BE USED.

B. VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE

WITH AMERICANS WITH DISABILITIES ACT MOUNTING HEIGHTS.

C. SUPPLY AND INSTALL CONTRACTORS SHALL VERIFY DIMENSIONS AND

CONNECTION POINTS PRIOR TO FABRICATION.

D. DIMENSIONS SHOWN ON THE FLOOR PLANS FOR GWB PARTITIONS ORIGINATE

AT COLUMN GRID LINES AND EXTEND TO FACE OF STUD, TYPICAL UNLESS

NOTED OTHERWISE.

E. MAINTAIN INTEGRITY OF FIRE RATED PARTITIONS BY PROVIDING FIRE BARRIERS

AT ALL OPENINGS, GAPS AND VOIDS. SEAL LARGE OPENINGS USING MATERIALS

CONSISTENT WITH WALL CONSTRUCTION. SEAL GAPS AND JOINTS BETWEEN

CONSTRUCTION MATERIALS USING A UL APPROVED FIRE RESISTANT

SEALER/FILLER.

F. DOORS ARE LOCATED 6" OFF ADJACENT WALL UNLESS OTHERWISE NOTED.

G. ALL WORK METHODS OF CONSTRUCTION ARE TO COMPLY WITH ALL FEDERAL,

STATE, REGIONAL AND LOCAL BUILDING REQUIREMENTS.

H. DO NOT SCALE DRAWINGS.

I. THE CONTRACTOR IS RESPONSIBLE TO VERIFY ALL DIMENSIONS AND

CONDITIONS AND REPORT ANY DISCREPANCIES TO THE ARCHITECT PRIOR TO

CONSTRUCTION.

J. THESE DOCUMENTS MAY NOT INDICATE THE ACTUAL FIELD CONDITIONS. THE

CONTRACTOR SHALL VERIFY ALL EXISTING FIELD CONDITIONS AND

COORDINATE WITH OTHER CONTRACTORS PRIOR TO STARTING WORK.

K. ALL MATERIALS AND SYSTEMS ARE TO BE CONSIDERED NEW UNLESS

OTHERWISE NOTED.

L. CONTROL JOINTS IN GYPSUM WALLS:

1. IN LONG EXPANSES SUCH AS CORRIDORS, CONTROL JOINTS SHOULD BE

PLACED AT A MAXIMUM OF 30 FEET. PROVIDE CONTROL JOINTS IN FIRE RATED

PARTITIONS AS RECOMMENDED BY MANUFACTURER. PROVIDE CONTROL

JOINTS AT ALCOVES ABOVE DOOR OPENINGS ALIGNED WITH SIDES OF

ALCOVES.

2. WHERE GYPSUM WALL IS LOCATED ABOVE MASONRY WALL, ALIGN THE

CONTROL JOINTS IN THE GYPSUM WALL WITH THE CONTROL JOINTS IN THE

MASONRY WALL.

M. DIMENSIONS TO EXISTING CONDITIONS ARE APPROXIMATE AND MUST BE FIELD

VERIFIED.

N. FIELD VERIFY ALL CONDITIONS PRIOR TO BEGINNING WORK. SALVAGE

MATERIAL AS DIRECTED BY OWNER.

O. DASHED LINES INDICATE EXISTING ITEMS TO BE REMOVED UNLESS NOTED

OTHERWISE.

P. DEMOLITION WORK SHALL BE COORDINATED WITH ALL

STRUCTURAL, ELECTRICAL, MECHANICAL, PLUMBING, ETC. TRADES PRIOR TO

THE START OF ANY DEMOLITION.

Q. PRIOR TO STARTING DEMOLITION, DUST CONTROL BARRIERS SHALL BE

CONSTRUCTED TO PREVENT THE SPREAD OF DUST INTO SURROUNDING

AREAS. REFER TO SPECIFICATION 02 41 19 SELECTIVE DEMOLITION FOR MORE

INFORAMTION.

R. EXISTING EXITS SHALL BE MAINTAINED AS REQUIRED BY OWNER DURING

DEMOLITION.

S. PATCH/REPAIR: WHERE EXISTING WALLS, FLOORS,CEILING

OR ROOFS HAVE BEEN DISTURBED BY DEMOLITION OR

CONSTRUCTION, OR WHERE EXISTING OPENINGS REMAIN AFTER

REMOVAL OF DUCTS, PIPING, CONDUIT, ETC. PATCH AND

RESTORE EXISTING WITH NEW MATERIALS AS REQUIRED TO

MATCH EXISTING SURFACES. PAINT ENTIRE SURFACE FULL

HEIGHT AND WIDTH. SEE ROOM FINISH SCHEDULE DRAWING.

PATCH CONCRETE FLOORS TO PROVIDE A SMOOTH LEVEL

SURFACE TO ACCEPT NEW FINISH.

T. PRIOR TO DEMOLITION, BEARING WALLS AND STRUCTURAL

MEMBERS SHALL BE LOCATED, ANY POTENTIAL CONCERNS

SHOULD IMMEDIATELY BE COMMUNICATED TO THE ARCHITECT.

U. DURING DEMOLITION, BRACING AND/OR SHORING SUPPORTS

SHALL BE REQUIRED TO PREVENT MOVEMENT OR SETTLEMENT

OF THE EXISTING STRUCTURE.

V. ACCESORIES LOCATION, REFERE TO STANDARD MOUNTING HEIGHTS

AND REQUIRMENTS ON SHEET OYA- 001. UNLESS OTHERWISE NOTED.

W. SALVAGE TO OWNER ALL REMOVED FIXTURES, FITTINGS, DOORS AND

FRAMES.

X. FOR FIRESTOPPING REFER TO SPECIFICATION 07 84 00.

Y. FOR METAL RAILINGS SEE SPEC 05 52 00 FOR MORE INFORMATION.

17" - 19"

8 6

TYPICAL CORRIDOR/AISLE FIXTURES - STANDARD MOUNTING HEIGHTS

ELECTRICAL

OUTLET

TELEPHONE OUTLETS

HOUSE TELEPHONE

MAUNAL PULL STATION

FIRE ALARM SIGNAL

EXIT SIGN

CARD READER AND STRIKE PLATE

INTERCOMMUNICATION

STATION

LIGHT SWITCH

TEMPERATURE SENSOR

STROBE 6'-8" TO BOTTOM

FIRE EXTINGUISHER SIGN

FIRE EXTINGUISHER,

WALL MOUNTED

FIRE EXTINGUISHER,

RECESSED CABINET OR

FIRE EXTINGUISHER,

VALVE CONNECTION

RECESSED CABINET

8 5

EMERGENCY

POWER OFF

ANNUNCIATOR PANEL

CORNER GUARD

54" MIN

12" MAX 42" MIN

T .O

B

A R

24" 12"

T .O

B

A R

16" - 18"

60" MIN

"T

Y P

H C

36" MAX

T Y

P

12" MAX

36"

EQ EQ

M A

X

7" - 9"

39" - 41"

36"

/2

6 3/4"

3"

3"

NOTE: MAX HEIGHT TO OPERABLE

PART OF TOILET

ACCESSORIES IS 40"

STANDARD MOUNTING HEIGHTS AND ADA REQUIREMENTS

STANDARD H/C COMPARTMENT

NOTES:

A VERIFY ACCESSORY SIZE WITH MANUFACTURER TO ENSURE CONFORMANCE WITH ADA MOUNTING HEIGHTS.

B DIMENSIONS TO TOILET ROOM ACCESSORIES ARE TO THE HIGHEST PORTION OF THE OPENING OR OPERATING DEVICE U.N.O.

C PROVIDE BACKING FOR INSTALLATION OF ALL WALL-MOUNTED ITEMS.

D PLACE ELECTRICAL AND TELEPHONE DEVICES AT 44 INCHES ABOVE FINISH FLOOR AT CREDENZAS AND COUNTERTOPS U.N.O.

E ALL RESTROOM ACCESSORIES TO BE INSTALLED PER THE MANUFACTURERS RECOMMENDED STANDARD MOUNTING HEIGHT, BUT SHALL NOT

EXCEED THE MAXIMUM REACH DIMENSIONS NOTED ABOVE AND AS REQUIRED BY ICC/ANSI 117.1.

STANDARD COMPARTMENTSTANDARD COMPARTMENT

SCD

TPD

PTD & WASTE UNIT (RECESSED)

COAT/UTILITY HOOKS

SD (NO PROTRUSION)

SANITARY NAPKIN

DISPENSER (RECESSED)

TPD

ND

WHERE

OCCURS

TPD

GB

SCD

GB

SEAT HEIGHT AND GRAB BAR

LOCATIONS

TPD

ND WHERE

OCCURS

SURFACE MOUNTED

DISPENSERS

PROTRUDING OBJECTS

MOUNTED NEAR GRAB BARS

TO LID T.O. LID

STANDARD H/C COMPARTMENT STANDARD H/C COMPARTMENT STANDARD H/C COMPARTMENT

PTD (RECESSED)

SD (W/PROTRUSION

GREATER THAN 11")

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:03 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-001

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E L E

G E

N D

S

A B

B R

E V

IA

T

IO

N

S

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

SAC-(#) SUSPENDED ACOUSTICAL CEILING - TYPE

SAT SUSPENDED ACOUSTICAL TILE

SCD SEAT COVER DISPENSER

SD SOAP DISPENSER

SECT SECTION

SF SQUARE FEET

S/H SEALER / HARDENER

SHT SHEET

SIM SIMILAR

S-INSUL STEEL INSULATED

SOW SCOPE OF WORK

SS STAINLESS STEEL OR SOLID SURFACE

STC SOUND TRANSMISSION COEFFICIENT

STD STANDARD

STL STEEL

STRUCT STRUCTURAL

SUSP SUSPENDED

TOC TOP OF CONCRETE

TOS TOP OF STEEL

TR TREAD

TS TUBE STEEL

TYP TYPICAL

UA UNASSIGNED

UL UNDERWRITERS LABORATORY

UMC UNIFORM MECHANICAL CODE

UNO UNLESS NOTED OTHERWISE

UPC UNIFORM PLUMBING CODE

V VENT

VERT VERTICAL

VEST VESTIBULE

VIB VIBRATION

VP VENT PIPE

VR VAPOR RETARDER

W/ WITH

WB-(#) WHITE BOARD - TYPE

WC-(#) WALLCOVERING - TYPE

WD WOOD

WF-(#) WINDOW FILM - TYPE

WOM WALK OFF MAT

W/O WITHOUT

WP-(#) DEMOUNTABLE PARTITION - TYPE

WT WEIGHT

WWP WOVEN WIRE PARTITION

LP LOW POINT

LSS LIFE SAFETY SYSTEMS

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MB-(#) MARKER BOARD - TYPE

MECH MECHANICAL

MEZZ MEZZANINE

MFR MANUFACTURER

MIN MINIMUM; MINUTE

MISC MISCELLANEOUS

MO MASONRY OPENING

MS MOP SINK

MTL METAL

NA NOT APPLICABLE

ND NAPKIN DISPOSAL

NEC NATIONAL ELECTRIC CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NR NOT FIRE RATED

NTS NOT TO SCALE

NV NAPKIN VENDOR

OC ON CENTER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI OWNER FURNISHED, OWNER INSTALLED

OHC OVERHEAD COILING DOOR

OPP OPPOSITE

OSHA OCCUPATIONAL SAFETY AND HEALTH ASSOCIATION

PCF PER CUBIC FOOT

PKG PACKAGE

PL PLATE

PLAM-(#) PLASTIC LAMINATE - TYPE

PLBG PLUMBING

PLYWOOD PLYWOOD

PNL PANEL

PR PAIR

PREFAB PREFABRICATED

PROC PROCESS

PSI POUNDS PER SQUARE INCH

P / T PASS THROUGH

PT-(#) PAINT SYSTEM - COLOR

PTD PAPER TOWEL DISPENSER

R RISER

RA RETURN AIR

RAG RETURN AIR GRILLE

RB-(#) RESILIENT BASE - TYPE

REF REFERENCE

REQD REQUIRED

RF-(#) RESILIENT FLOORING - TYPE

RM ROOM

RO ROUGH OPENING

ROM ROUGH ORDER OF MAGNITUDE

RRD RAPID ROLL-UP DOOR

S STAIN

EL/ELEV ELEVATION OR ELEVATOR

EMERG EMERGENCY

EOD EDGE OF DECK

EQ EQUAL

EQUIP EQUIPMENT

EXP EXPOSED

EXT EXTERIOR

FACT FACTORY

FE-(#) FIRE EXTINGUISHER - TYPE

FF FINISH FLOOR

FF&E FURNITURE, FIXTURES AND EQUIPMENT

FFU FAN FILTER UNIT

FG FINISH GRADE

FIN FINISH

FLG FLASHING

FLR FLOOR

FM FACTORY MUTUAL

FMS FACILITIES MANAGEMENT SYSTEM

FO FACE OF

FOC FACE OF CONCRETE

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOP FACE OF PANEL

FOS FACE OF STUDS / STEEL

FT FOOT/FEET

GA GAUGE

GALV GALVANIZED

GB GRAB BAR

GWB GYPSUM WALL BOARD

GL-(#) GLASS - TYPE

GR GRILLE

GT-(#) GROUT - TYPE

GYP GYPSUM

HB HOSE BIBB

HC HOLLOW CORE

HDWR HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HP HIGH POINT

HPC HIGH PERFORMANCE COATING

HR HOUR

HS HIGH STRENGTH

HT HEIGHT

IBC INTERNATIONAL BUILDING CODE

IECC INTERNATIONAL ENERGY CONSERVATION CODE

IFC INTERNATIONAL FIRE CODE

IN INCH/INCHES

INSUL INSULATION

INT INTERIOR

IPC INTERNATIONAL PLUMBING CODE

IWUIC INTERNATIONAL WILDLANDS URBAN INTERFACE CODE

JT JOINT

LAM LAMINATED

LB LOUVERED BLINDS / POUND

@ AT

ø DEGREE

° DIAMETER

CENTERLINE

AC-(#) ACOUSTICAL TILE - TYPE

ACP ALUMINUM CHECKER PLATE

ADA AMERICANS WITH DISABILITIES ACT

AF-(#) ACCESS FLOOR - TYPE

AFF ABOVE FINISH FLOOR

ALT ALTERNATE

ALUM ALUMINUM

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

APPROX APPROXIMATE

ARCH ARCHITECTURAL

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

B/ BOTTOM OF

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BM BEAM

BOS BOTTOM OF STEEL

CCS CLEANROOM CEILING SYSTEM

CF CUBIC FEET

CG-(#) CORNER GUARD - TYPE

CHK CHECKERED

CIP CAST-IN-PLACE

CJ CONTROL JOINT

CLG CEILING

CLR CLEAR

CMU CONCRETE MASONRY UNIT

COL COLUMN

CONC CONCRETE

CONF CONFERENCE

CONT CONTINUOUS

COORD COORDINATE

CPT-(#) CARPET - TYPE

CR CARD READER

CR-(#) CRASH RAIL - TYPE

CRC CHEMICAL RESISTANT COATING

CS CONCRETE SEALER

CT-(#) CERAMIC TILE - TYPE

CTR CENTER

CWS-(#) CLEAN ROOM WALL SYSTEM - TYPE

DF DRINKING FOUNTAIN

DIA DIAMETER

DIM DIMENSION

DN DOWN

DR DOOR

DRB DESIGN REVISION BULLETIN

DTL DETAIL

DWG DRAWINGS

(E) EXISTING

EA EACH

EJ-(#) EXSPANSION JOINT - TYPE

ELEC ELECTRIC

CONTROL

ROOM

GYM

STATE HOUSING

UNIT

ADMINISTRATION

OUTDOOR

RECREATION

SCOPE

OF

WORK

SUPPORT

SERVICES

B

SALLY

PORT

BE-2

I-3

SALLY

PORT

I-3

A-3

STATE HOUSING

UNIT

I-3

STATE HOUSING

UNIT

I-3

PUBLIC WAY

SIDEWALK

P R

O P

E R

T Y

L

IN

E

NOTE F1

N O

T E

G

PROPERTY LINE

NOTE G4

P R

O P

E R

T Y

L

IN

E

N

(TYPICAL)

(T Y

P

IC

A L

(T Y

P

IC

A L

DISPERSAL AREA

(1996 OSSC SECTION 1021)

TR

A V E L D

IS

TA

N C E 89'-0"

AREA OCCUPANCY LEGEND

OCCUPANCY CLASSIFICATION: A-3

OCCUPANCY CLASSIFICATION: E-2

OCCUPANCY CLASSIFICATION: B

OCCUPANCY CLASSIFICATION: I-3

SMOKE CONTROL ZONE

FIRE SEPARATION WALLS

1 HOUR OCCUPANCY SEPARATION WALL

2 HOUR OCCUPANCY SEPARATION WALL

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:04 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-002

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E C

O D

E P

L A

N

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 1" = 20'-0"

1 CODE ANALYSIS

SEPARATION; DISPERSAL

AREA REQUIREMENT

(1996 OSSC SECTION

1021)

2HR

H

R

H

R

2HR

BUILDING CODE ANALYSIS HARNEY COUNTY FACILITY / BURNS, OREGON

(BASED ON STATE OF OREGON STRUCTURAL SPECIALTY CODE, 1994 EDITION

A. OCCUPANCY CLASSIFICATION

SPACE CLASSIFICATION ACTUAL AREA % TOTAL AREA ALLOWABLE AREA

GYMNASIUM A-3 3965 S.F 12% 6552 S.F

VACATIONAL EDUC, E-2 1790 S.F 5% 4050 S.F

NON-DETENTION 8770 S.F 26% UNLIMITED

AREAS

DETENTION HOUSING I-3 19,650 S.F 57% 42582 S.F

TOTAL 34,175 S.F 100%

B. CONSTRUCTION LIMITATIONS

OCCUPANCY CONST. TYPE MAX. AREA ALLOWABLE INCREASES MAX. HEIGHT

A-3 II - N 9,100 S.F 54,600 1 STORY

E-2 II - N 13,500 S.F 81,000 1 STORY

B II - N 12,000 S.F UNLIMITED 2 STORY

I-3 I or II F.R 15,100 S.F 90,600 2 STORY

C. BUILDING AREA INCREASES (SECTION 505)

1. SEPARATION ON ALL SIDES - 100 % INCREASE.

2. UNLIMITED INCREASE FOR 1-STORY, B OCCUPANCY, FULLY SPRINKLERED.

3. AUTOMATIC SPRINKLER SYSTEM - 200 % INCREASE.

D. OCCUPANCY REQUIREMENTS

1. GROUP I-3 SHALL BE HOUSED IN TYPE I OR TYPE II F.R CONSTRUCTION.

E. OCCUPANCY SPEARATION ( TABLE 3-B)

1. A-3 / B-N

2. A-3 / 1-3, 2-HR

3. B / I-3, 2HR

4. B / E-2, 1HR

F. EXTERIOR WALL REQUIREMENTS (TABLE 5A)

1. A-3 N.R., N.C. GREATER THAN 20' FROM PROPERTY LINE

2. E-2 N.R., N.C. GREATER THAN 10' FROM PROPERTY LINE

3. B N.R., N.C. GREATER THAN 20' FROM PROPERTY LINE.

4. I-3 BEARING WALL: 4-HR / N.C.

NON-BEARING WALLS: N.R / N.C. GREATER THAN 40' FROM PROPERTY LINE.

G. EXTERIOR WALL OPENING REQUIREMENTS ( TABLE 5A)

1. A-3 N.R. GREATER THAN 10' FROM PROPERTY LINE.

2. E-2 N.R. GREATER THAN 10' FROM PROPERTY LINE.

3. B N.R. GREATER THAN 10' FROM PROPERTY LINE.

4. I-3 N.R. GREATER THAN 20' FROM PROPERTY LINE.

DN

CONTROL

ROOM

EXISTING

HOUSING

UNIT

NOT PART OF

PROJECT

SCOPE

EXISTING

GYM

NOT PART OF

PROJECT

SCOPE

EXISTING

HOUSING

UNIT

NOT PART OF

PROJECT

SCOPE

EXISTING ADMINISTRATION

BUILDING

COURTYARD

SCOPE

OF

WORK

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:04 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-100

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E F

IR

S

T F

L O

O R

P L

A N

O V

E R

A L

L

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

N

OBS #2 OBS #1

CONTROL ROOM

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

(D) RAISED ACCESS FLOOR PANELS,

SEE NEW SCOPE FOR REUSE OF

EXISTING PEDESTALS /

COMPONENTS WHERE POSSIBLE

(D) VINYL

FLOOR TILE

(E) HANDRAIL TO

BE REMOVED

(D) EXISTING FURNITURE,

CABINETS, RACKS, SHELVES.

COORDINATE DISPOSITION WITH

OWNER

(D) VINYL

FLOOR

TILE

RESTROOM

(D) PANELS. (N) FINISH TO

BE INSTALED ON STEPS

AND RAISED ACCES FLOOR

SYSTEM

(D) EXISTING

OBSERVATION

WINDOWS AND

PORTION OF CMU WALL

TO ACCOMMODATE

FOR NEW WINDOWS

(D) EXISTING CMU WALL TO

ACCOMMODATE FOR NEW

DOOR OPENING. SEE NEW

FLOOR PLAN AND DOOR

SCHEDULE FOR DOOR SIZE.

OYA-200

OYA-200

(E) FIRE ALARM TO BE

RELOCATED. REFER TO

MEP DRAWINGS FOR

MORE INFORMATION

(E) DOOR TO

COURTYARD

OYA-200

(E) GYPSUM BD.

CEILING TO

REMAIN. PATCH

AND REPAIR IF

NECESSARY

(D) GYPSUM SOFFIT

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

(D) ACT, SMOKE

DETECTORS,

SENSORS AND

CEILING GRIDS.

(E) SPRINKLER.

REFER TO MEP

DRAWINGS FOR

MORE INFORMATION

(E) DIFFUSER.

REFER TO MEP

DRAWINGS FOR

MORE INFORMATION

(D) ALL EXISTING LIGHT

FIXTURES. REFER TO MEP

DARWINGS FOR MORE

INFORMATION

(D) ALL EXISTING LIGHT

FIXTURES. REFER TO MEP

DARWINGS FOR MORE

INFORMATION

(D) GYPSUM SOFFIT

(E) SPRINKLER.

REFER TO MEP

DRAWINGS FOR

MORE INFORMATION

FINISH FLOOR

DEMO EXISTING CMU

WALL TO

ACCOMMODATE FOR

NEW DOOR OPENING.

REFER TO DOOR

SCHEDULE FOR

DOOR SIZE

PATCH/ INFILL

OPENING

EDGES WITH

MORTAR/GROUT

AS NECESSARY

EXISTING HANDRAIL

TO BE REMOVED

EXISTING CMU WALL

REFER TO DEMO

NOTES AND DETAILS

ON SHEET OYA-600

FOR MORE

INFORMATION

EXISTING

PEDESTALS TO

REMAIN

(D) EXISTING

PANELS. PROVIDE

NEW. REFER TO

FINISH SCHEDULE

EXISTING CMU WALL

0' - 0"

WT5X11

6" 4" MIN.

BOLTS SPACED AT 8"

TEMPORARY SHORING.

SEE DETAIL 5

2 BOLTS EA. SIDE IN

CONTINOUS CMU

FINISH FLOOR

0' - 0"

RAISED ACCES FLOOR

2' - 8"

(D) EXISTING

WINDOW. OPENING

LOWERED TO JUST

ABOVE RAF

DEMO PART OF EXISTING CMU

WALL TO ACCOMMODATE FOR

NEW WINDOW. REFER TO

WINDOW SCHEDULE FOR SIZE.

PATCH/ INFILL

OPENING

EDGES WITH

MORTAR/GROUT

AS NECESSARY

NOTE : REFER TO

DEMO NOTES AND

DETAILS ON SHEET

OYA-600 FOR MORE

INFORMATION

VIF VIF

THRU-BOLTS

SPACED AT 8"

TEMP.

CHANNELS

C6X8.2

CONTROL ROOM

CMU ADMINISTRATION

OFFICE

NOTE: SHORING COULD BE 2 CHANNELS

(C6X8.2) SANDWITCHING THE WALL.

SEQUENCE:

1. DRILL HOLES THRU CMU WALL

2. THRU-BOLT AND ATTACH CHANNELS,

EXTENDING 6-8" PAST AREA BEING DEMO-ED

3. DEMO WALL AS SHOWN IN HATCHED AREA

4. INSTALL NEW CHANNEL

5. INFILL WITH BLOCK, RE-GROUT ALL JOINTS

6. REMOVE CHANNELS AND BOLTS

7. PATCH/PAINT WALL TO CONCEAL HOLES

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:05 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-200

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E D

E M

O L

IT

IO

N F

L O

O R

P L

A N

C O

N T

R O

L R

O O

M

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 1/2" = 1'-0"

1 DEMOLITION FLOOR PLAN - CONTROL ROOM

- 1/2" = 1'-0"

2 DEMOLITION REFLECTED CEILING PLAN - CONTROL ROOM

DEMO GENERAL NOTES:

- 1/2" = 1'-0"

3 ELEVATION - DEMO NEW DOOR OPENING

- 1/2" = 1'-0"

4 ELEVATION - DEMO NEW WINDOW OPENING

- 1" = 1'-0"

5 SHORING DETAIL

1. UNLESS OTHERWISE INDICATED ON THE DRAWINGS OR IN THE

SPECIFICATIONS, THE FOLLOWING NOTES SHALL APPLY.

2. BEFORE ANY DEMOLITION IS TO BE PERFORMED IN THE AREA OF

WORK, A PROTECTIVE BARRIER WILL HAVE TO BE IN PLACE TO

PROTECT THE WORK AREA FROM THE ADMINISTRATION AREA

SUCH AS A POLYETHYLENE FILM SHEETING.

3. REFER TO MECHANICAL, PLUMBING, FIRE PROTECTION AND

ELECTRICAL DEMOLITION DRAWINGS FOR EXTENT OF

DEMOLITION OF MECHANICAL, PLUMBING, FIRE PROTECTION AND

ELECTRICAL ITEMS.

4. REMOVE AND DISPOSE OF ALL EXISTING EQUIPMENT AS

INDICATED ON THE DRAWINGS AS REQUIRED. EQUIPMENT

DESIGNATED FOR REUSE IS TO BE REMOVED AND STORED PER

OWNER/ CONSTRUCTION MANAGER DIRECTION.

5. DEMOLITION CONTRACTOR TO REVIEW NEW WORK

CONSTRUCTION DOCUMENTS FOR SCOPE, INTENT AND

COORDINATION WITH DEMOLITION.

6. REVIEW AND VERIFY PATH FOR REMOVAL OF TRASH/ DEBRIS

FROM PROJECT LOCATION WITH CONSTRUCTION MANAGER

PRIOR TO BEGINNING WORK.

7. DEMOLITION CONTRACTOR TO REPORT ANY FIELD CONDITIONS

THAT VARY FROM THOSE INDICATED ON THE DOCUMENTS.

8. DEMOLITION CONTRACTOR TO ADVISE CONSTRUCTION

MANAGER OF PARTITIONS OR WALLS REMAINING THAT HAVE

BEEN WEAKENED AFTER DEMOLITION AND ARE UNSAFE OR

UNSALVAGEABLE.

9. DEMOLITION CONTRACTOR TO INDICATE ANY ELECTRICAL RISER

OR PLUMBING RISER UNCOVERED WITHIN A DEMOLISHED

PARTITION. INCLUDES MECHANICAL DUCT SHAFTS NOT

INDICATED ON DOCUMENTS.

10. DEMOLITION CONTRACTOR TO SAFELY SECURE ANY AND ALL

PIPING, WIRING, CABLES OR DEVICES THAT ARE NOT

SCHEDULED FOR DEMOLITION AND WHERE SECURED BY ITEMS

(PARTITIONS) THAT HAVE BEEN OR ARE SCHEDULED FOR

DEMOLITION.

11. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR STRUCTURAL

INTEGRITY OF EXISTING BUILDING WHERE PART OR PORTIONS

OF STRUCTURE/WALLS HAVE BEEN REMOVED.

12. DEMOLITION CONTRACTOR IS RESPONSIBLE FOR PROTECTING

ALL STRUCTURE, WALLS, DOORS, MEP ITEMS, ETC. THAT ARE

REQUIRED TO REMAIN.

13. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND

EXISTING CONDITIONS, INCLUDING BUT NOT LIMITED TO: WALLS,

FLOORS, MECHANICAL CONSTRUCTION, EXISTING

CONSTRUCTION TO REMAIN, EXISTING CONSTRUCTION TO BE

DEMOLISHED.

14. DEMOLITION CONTRACTOR TO VERIFY WITH OWNER AND/ OR

CONSTRUCTION MANAGER THOSE ITEMS THAT ARE TO BE

SALVAGED PER OWNER'S INSTRUCTIONS PRIOR TO BEGINNING

WORK.

15. COORDINATE WITH CONSTRUCTION MANAGER FOR TEMPORARY

PARTITIONS AS REQUIRED BY DEMOLITION WORK.

15. MARK THE OPENING SIZE FOR THE DOOR / WINDOWON BOTH

SIDES OF THE WALL. REFER TO SCHEDULE FOR DOOR/WINDOW

SIZE.

16. SAW CUT USING MASONRY CIRCULAR SAW BLADE. OPENING

SHOULD BE TWO INCHES WIDER THAN THE DOOR

FRAME, AND ABOUT AN INCH TALLER IN HEIGHT. ADD

ANOTHER SET OF MARKS ACROSS THE TOP OF THE

FRAME TO REPRESENT A STEEL LINTEL THAT WILL

SUPPORT THE LOAD ABOVE THE DOOR. THE LINTEL

SHOULD BE CENTERED OVER THE DOOR. IT SHOULD

ALSO EXTEND 6 INCHES PAST THE DOOR FRAME ON

EITHER SIDE. INFILL EACH SIDE OF THE OPENING BELOW LINTEL.

17. COORDINATE STORAGE OR DISPOSAL LOCATION WITH

CONSTRUCTION SUPERINTENDENT.

18. FOR MORE INFORMATION REFER TO SPECIFICATION 02 41 19

SELECTIVE DEMOLITION.

DN DN

292 SF

CONTROL ROOM

OYA-500

OYA-500 1

OYA-500

37 SF

RESTROOM

(R) SECURITY

EQUP. BOARD

(E) COFFEE MAKER

(E) MICROWAVE

(E) UNDER COUNTER

REFRIGERATOR

(R) DOOR

RELEASE BUTTON

(N) 3'-0" HIGH

COUNTERTOP - COUNTER

SPACE TO ACCOMODATE

MISC. EQUIPMENT

INCLUDING BUT NOT

LIMITED TO PRINTER,

RADIO CHARGING, ETC

(N) KEY

BOX

(N) STORAGE

/ CUBBY

CABINET

(E) ELEC

PANELS

(N) FLOOR FINISH ON

RAISED ACCESS FLOOR

SYSTEM, REFURBISH

EXISTING TILES IF

AVAILABLE

(N) SMALL KITCHEN SINK,

PLUMBING CONNECTIONS

THROUGH ADJACENT TOILET

ROOM CHASE

(N) DESK/CHAIR WITH

IT RACK UNDER TO

ACCOMODATE (4) CPU

+ POSSIBLE

EXPANSION

(E) PHONE

(N) DOOR TO ADJACENT

ADMINISTRATION SPACE

MANUALLY KEY LOCKED

WITH DOOR POSITION

MONITORING. REFER TO

SHEET OYA-700 FOR MORE

INFORMATION.

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

(N) BASE CABINETS TO

ACCOMODATE MISC.

STORAGE INCLUDING

BUT NOT LIMITED TO

BINDERS, OFFICE

SUPPLIES, BREAK AREA

SUPPLIES, ETC. REFER

TO SHEET OYA-302 FOR

MORE INFORMATION

(N) ELECTRIC

MOTOR SUN

SHADE AT (E)

WINDOW

(N) WALL MOUNTED

WASTE BASKET

(N) TOILET SEAT

COVER DISPENSER

(N) GLOVE BOX

HOLDER - 5 BOX

CAPACITY

(R) PAPER TOWEL

DISPENSER (OFOI)

SOAP DISPENSER (OFOI)

TOILET PAPER

DISPENSER (OFOI)

(N) LOWER

WINDOWS, PROVIDE

(N) ONE-WAY FILM

AND BLINDS

(N) INSTANT HOT

WATER DISPENSER

(N) MOP/ BROOM

HOLDER

(E) RAILING

(N) VCT

(N) VCT

(E) DOOR TO

COURTYARD

(E) STEPS. (N) FINISH TO BE

INSTALED

(N) HANDRAIL.

SEE ELEVATIONS

(N) FLAT

SCREEN

MONITOR ON

WALL MOUNT

ABOVE

WINDOW. SEE

ELEVATIONS

(N) ELECTRIC

MOTOR SUN

SHADE AT (E)

WINDOW

OYA-500

(E) TRANSACTION

DRAWER, (N)

CUSTOM CASEWORK

BUILT TO FIT. SEE

SHEET OYA-302

C O

U R

T Y

A R

D

(R) EXISTING

FIRE ALARM

(N) UPPER CABINETS.

REFER TO SHEET

OYA-302 FOR MORE

INFROMATION

OYA-500

OYA-500 1

OYA-500

OBS #2 OBS #1

292 SF

CONTROL ROOM

37 SF

RESTROOM

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

OYA-500

101B

101A

102A

FINISH PLAN GENERAL NOTES

A. ALL FLOORING TO EXTEND UNDER NEW MILLWORK, SHELVING AND EQUIPMENT.

B. FLOOR MATERIAL TRANSITIONS SHALL OCCUR UNDER THE CENTERLINE OF DOOR IN CLOSED POSITION.

C. NEW BASE THROUGHOUT SHALL BE RB1, UNO.

D. GWB CONSTRUCTION THROUGHOUT SHALL BE PT1 AND PT2 FOR RESTROOM, UNO. SEE SPEC 09 91 26 FOR MORE

INFORMATION

E. CLOSETS SHALL BE FINISHED TO MATCH ADJACENT SPACE, UNO.

F. GWB CEILINGS AND SOFFITS THROUGHOUT SHALL BE PAINTED PT1, UNO. .

G. DOORS, DOOR/ WINDOW FRAMES SHALL BE PAINTED IN SEMI-GLOSS FINISH. UNO. SEE SPEC 09 91 26 FOR MORE

INFORMATION

H. SEAMS IN RESILIENT BASE AT OUTSIDE CORNERS ARE NOT PERMITTED. ALL RESILIENT BASE TO BE PURCHASED IN 100'

ROLLED STOCK, NOT 48" INDIVIDUAL LENGTHS.

I. PROVIDE APPROPRIATE METAL TRANSITION STRIPS CENTERLINE AT EVERY FLOORING TRANSITION, UNLESS OTHERWISE

NOTED.

J. COORDINATE FLOORING INSTALLATION WITH ELECTRICAL DRAWINGS FOR ANY PROPOSED FLOOR POWER / DATA

RECEPTACLES. PATCH FLOOR SLAB AND FIT FLOOR FINISHES AROUND OUTLETS AS REQUIRED.

K. ALL GWB FINISH LEVELS AS INDICATED BY MANUFACTURER OF WALL-APPLIED PRODUCTS INCLUDING MARKERBOARDS, MARKERBOARD PAINTS, WALLCOVERING, AND TILE.

L. AT SOLID SURFACE SURFACES, ALL SEAMS TO BE FILLED W/ MANUFACTURER'S JOINT ADHESIVE. TO BE SANDED AND

BUFFED SMOOTH - NO VISIBLE SEAM, TYP

M. REFER TO SPECIFICATION 09 69 00 ACCESS FLOORING. FOR MORE INFORMATION.

CEILING

WALL

BASE

FLOOR

FINISH SYMBOL LEGEND:

PT2

RB1

VCT1

EXISTING

PT1

RB1

AFP1/VCT1

ACT1

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:05 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-300

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E F

IR

S

T F

L O

O R

P L

A N

C O

N T

R O

L R

O O

M

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 1/2" = 1'-0"

1 FLOOR PLAN - CONTROL ROOM

- 1/2" = 1'-0"

2 FLOOR PLAN - CONTROL ROOM FINISH PLAN

12/12/2023

SUSPENDED ACOUSTIC

CEILING GRID

HANGER WIRE ANCHORED

TO STRUCTURE ABOVE

ACOUSTICAL CEILING TILE

CEILING GRID EDGE ANGLE

STABILIZER BAR, OR

OTHER SUITABLE

SYSTEM, TO KEEP

PERIMETER

COMPONENTS FROM

SPREADING

FASTENER, TYP

AT INSULATED METAL WALL

PANELS USE FASTENERS

RECOMMENDED BY IMP

CONT. BACKING

SEE PLAN FOR WALL TYPE

CONTROL

ROOM

RESTROOM

(E) GYPSUM BD.

CEILING TO

REMAIN. PATCH

AND REPAIR IF

NECESSERY.

PAINT PT2

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

EQEQ

(N) ACOUSTIC CEILING

TILES AND GRIDS.

REFER TO FINISH

SCHEDULE FOR MORE

INFORMATION

ACT 1

10'-8" A.F.F

(N) DIMMABLE LIGHT

FIXTURE. REFER TO

ELECTRICAL

DRAWINGS FOR MORE

INFORMATION

(E) HVAC SYSTEM.

RELOCATE IF

NECESSARY. REFER

TO MECHANICAL

DRAWINGS FOR MORE

INFORMATION

(N) DIMMABLE LIGHT

FIXTURE. REFER TO

ELECTRICAL

DRAWINGS FOR MORE

INFORMATION

(E) SPRINKLER TO

REMAIN. RELOCATE IF

NECESSARY. REFER

TO MEP DRAWINGS

FOR MORE

INFORMATION

(N) DIMMABLE LIGHT

FIXTURE. REFER TO

ELECTRICAL

DRAWINGS FOR MORE

INFORMATION

CONTROL

ROOM

10' - 8" AFF

(E) SPRINKLER TO

REMAIN. RELOCATE IF

NECESSARY. REFER

TO MEP DRAWINGS

FOR MORE

INFORMATION

(E) SPRINKLER TO

REMAIN. RELOCATE IF

NECESSARY. REFER

TO MEP DRAWINGS

FOR MORE

INFORMATION

(N) ACOUSTIC CEILING

TILES AND GRIDS.

REFER TO FINISH

SCHEDULE FOR MORE

INFORMATION

(N) DIMMABLE LIGHT

FIXTURE. REFER TO

ELECTRICAL

DRAWINGS FOR MORE

INFORMATION

(N) DIMMABLE LIGHT

FIXTURE. REFER TO

ELECTRICAL

DRAWINGS FOR MORE

INFORMATION

A. PROVIDE GYPSUM HEADERS ABOVE DEMOUNTABLE WALLS TO DECK, UNLESS

OTHERWISE NOTED.

B. LIGHT FIXTURE LOCATION TAKES PRECEDENCE OVER THE LOCATION OF EVERY OTHER

CEILING DEVICE OR ABOVE CEILING ELEMENT. FIXTURE MUST BE INSTALLAED WHERE

INDICATED AND DIMENSIONED.

C. FOR ALL NEW NEW CONTINOUS GWB CEILING: PROVIDE 5/8" GWB ON METAL FRAMING

SECURED TO SLAB ABOVE. FINISH HEIGHT AS DESIGNATED. PROVIDE ADDITIONAL

FRAMING FOR LIGHT FIXTURES AND OTHER ASSOCIATED CEILING DEVICES. RETURN

GWB TO 6" ABOVE FINISHED CEILING.

D. CEILINGS TO BE INSTALLED IN STRICT ACCORDANCE WITH MANUFACTURERS'

SPECIFICATIONS, LOCAL BUILDING CODES AND ALL OTHER APPLICABLE CODES.

PROVIDE LATERAL BRACING AS REQUIRED. FOR MORE INFORMATION SEE

SPECIFICATION 09 51 13 ACOUSTICAL PANEL CEILINGS.

E. VERIFY ALL CEILING HEIGHTS AND CEILING PLENUM CLEARANCES TO ASSURE FINISHED

CEILING HEIGHTS CALLED OUT ON ARCHITECT DOCUMENTS. ANY DISCREPANCIES

SHALL BE BROUGHT TO ARCHITECT'S ATTENTION IMMEDIATELY, PRIOR TO

COMMENCEMENT OF WORK.

F. ANY CONFLICTS OR DISCREPANCIES AMONG FIXTURES, FIRE AND SMOKE DETECTION

DEVICES, HVAC OR OTHER CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF

ARCHITECT FOR CLARIFICATION.

G. COORDINATE REQUIRED ACCESS PANELS AT NEW GWB CEILINGS WITH ARCHITECT

PRIOR TO INSTALLATION.

H. ALL DIMENSIONS ARE TO CENTERLINE OF FIXTURE, UNLESS NOTED OTHERWISE.

I. ALL CEILING GRIDS TO BE CENTERED IN SPACES WITH EQUAL TILES AT OPPOSITE SIDES

AS SHOWN UNLESS NOTED OTHERWISE.

J. ALL CEILING MOUNTED FIXTURES TO BE CENTERED ON LAY-IN PANELS IN SUSPENDED

CEILING AREAS AS SHOWN, UNLESS NOTED OTHERWISE.

K. PROVIDE ADDITIONAL FIRE-RESISTANT BLOCKING AND/OR ANCHORING ABOVE CEILINGS

AS REQUIRED FOR SUPPORT OF LIGHT FIXTURES.

L. ALL EXPOSED WIRING, CONDUIT, AND CABLES, TO BE NEATLY ARRANGED IN

COORDINATION WITH CEILIGN LAYOUT. NO 'SAGGING' WIRES OR CABLES IS

ACCEPTABLE.

M. REFER TO ELECTRICAL E-SERIES DRAWINGS FOR EMERGENCY LIGHTING LOCATIONS /

LAYOUT.

N. NOTIFY DESIGNER/ARCHITECT OF EXISTING ELECTRICAL CONFLICTS THAT MAY

INTERFERE WITH NEW LIGHTING LAYOUT.

O. SPRINKLER HEADS, HVAC DIFFUSER/RETURN GRILES TO BE RELOCATED IF NECESSARY.

REFER TO MECHANICAL DRAWINGS FOR MORE INFORMATION.

REFLECTED CEILING PLAN GENERAL NOTES

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:05 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-301

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E R

E F

L E

C T

E D

C E

IL

IN

G P

L A

N C

O N

T R

O L

R O

O M

- 1/2" = 1'-0"

1 REFLECTED CEILING PLAN - CONTROL ROOM

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 3" = 1'-0"

3 ACT PERIMETER @ INT WALL, TYP.

DN DN

OYA-500

OBS #2 OBS #1

292 SF

CONTROL ROOM

37 SF

RESTROOM

(N) 3'-0" HIGH

COUNTERTOP -

COUNTER SPACE TO

ACCOMODATE MISC.

EQUIPMENT INCLUDING

BUT NOT LIMITED TO

PRINTER, RADIO

CHARGING, ETC

(N) SMALL KITCHEN

SINK, PLUMBING

CONNECTIONS

THROUGH ADJACENT

TOILET ROOM CHASE

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

(N) BASE CABINETS -

CABINETS TO

ACCOMODATE MISC.

STORAGE INCLUDING

BUT NOT LIMITED TO

BINDERS, OFFICE

SUPPLIES, BREAK AREA

SUPPLIES, ETC

(E) TRANSACTION

DRAWER, (N)

CUSTOM CASEWORK

BUILT TO FIT. REFER

TO SHEET OYA-600

FOR MORE

INFORMATIONS

C O

U R

T Y

A R

D

(N) STORAGE

/ CUBBY

CABINET. SEE

ELEVATIONS

2' - 0"

1' - 10"

/4

1' - 0"

135°

2' - 1"

2' - 6"

101B

101A

102A

(N) POWER

OUTLET, TYP.

(N) POWER

OUTLET, TYP.

(N) POWER /

DATA OUTLET,

TYP.

(N) POWER

OUTLET, TYP.

(N) POWER /

DATA OUTLET,

TYP.

OYA-6005

OYA-600

OYA-600 3

(N) UPPER

CABINETS. SEE

OYA-600 FOR

MORE

INFORMATION

OBS #2 OBS #1

292 SF

CONTROL ROOM

37 SF

RESTROOM

(E) COFFEE MAKER

(E) MICROWAVE

(E) UNDER COUNTER

REFRIGERATOR

(R) DOOR

RELEASE BUTTON

(N) STORAGE

/ CUBBY

CABINET

(E) ELEC

PANELS

(E) PHONE

EXISTING HOUSING UNIT

NOT PART OF PROJECT

SCOPE

EXISTING

ADMINISTRATION

BUILDING

NOT PART OF PROJECT

SCOPE

(N) TOILET SEAT

COVER DISPENSER

SOAP DISPENSER

(OFOI)

TOILET PAPER

DISPENSER (OFOI)

C O

U R

T Y

A R

D

(R) EXISTING

FIRE ALARM

E07

E07

E07

E07

E04

E03

E03

E03

E04

E04

E01

E02

E08 E05

T04 T01

T03

T02

01 01

101B

101A

102A

E03

E04

1. FURNITURE SHOWN FOR REFERENCE ONLY. COORDINATE LAYOUT WITH OWNER'S

FURNITURE PROVIDER. FOR MORE INFORMATION REFER TO SPEC 12 00 00.

2. REFER TO FURNITURE DOCUMENT / SPECIFICATIONS FOR ALL FURNITURE

DESIGNATIONS AND LOCATIONS.

3. CONTRACTOR RESPONSIBLE FOR COORDINATING WITH OWNER'S AV. CONTRACTOR

AND FURNITURE VENDOR TO COORDINATE LOCATIONS OF ELECTRICAL AND AV

CONNECTIONS REQUIRED TO BE INTEGRATED IN THE FURNITURE AND AT THE

PARTITIONS.

4. LINES SHOWN HALF-TONE REPRESENT MILLWORK, CASEWORK, AND EQUIPMENT

ITEMS THAT ARE INTENDED TO BE INCLUDED IN THE BASE BID CONTRACT. ITEMS

SHOWN WITH SOLID LINES ARE INTENDED AS PART OF THE FURNITURE CONTRACT.

5. DIMENSIONS FOR REFERENCE ONLY. ALL DIMENSIONS AND CONDITIONS TO BE

REVIEWED ON SITE PER BUILT CONSTRUCTION. REFER TO PARTITION PLANS FOR

DIMENSIONAL LAYOUT.

FURNITURE PLAN GENERAL NOTES

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:06 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-302

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E E

N L A

R G

E D

F U

R N

IT

U

R E

P L

A N

A N

D E

Q U

IP

M

E N

T

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 1/2" = 1'-0"

1 FLOOR PLAN - ENLARGED FURNITURE PLAN

- 1/2" = 1'-0"

2 FLOOR PLAN - ENLARGED EQUIPMENT PLAN

E08

KEY BOX HOLDER 60-KEY HEVY

DUTY DIGITAL LOCK

ADIROFFICE 680-60-WHT OFCI 1 17" x 13" x 2 1/2"

E07 WINDOW SHADES MECHO SHADE MECHO/7 OFCI VIF POWER ELECTRIC

E06 MINI FRIDGE TBD TBD OFCI UNDER COUNTER

E05

INSTANT HOT WATER

DISPENSER

INSINKERATOR H-HOT100C-SS OFCI 1 TBD

E04 MONITOR TBD TBD OFCI 4 43"

MOUNTED ABOVE THE WINDOW.

FOLLOW MANUFACTURE

RECOMENDATION FOR MOUNTING

E03 CONSOLE MONITOR TBD TBD OFCI 4 24"

FOLLOW MANUFACTURER

RECOMENDATION FOR SIZES AND

MONITOR ARMS

E02 DESK CHAIR TBD TBD OFCI 1

E01

VISIONLINE 24/7 CONSOLE,

LARGE 89" W

MIDDLE ATLANTIC LH-VLCLHS OFCI 1 89" WIDTH

T04 MOP / BROOM HOLDER TBD OFCI 1 11" WIDTH STAINLESS STEEL FINISH

T03 GLOVE BOX GLOBAL INDUSTRIAL T9AB2222415 OFCI 1 3 3/4" x 16" x 10" STAINLESS STEEL FINISH

T02

TOILET SEAT COVER

DISPENSER

ASI T9AB201858 OFCI 1 2 5/8" x 15 3/4" x 11 1/4" STAINLESS STEEL FINISH

T01 WALL MOUNT TRASH CAN GLOBAL INDUSTRIAL T9A641438SS OFCI 1 7 1/2" x 15 1/4" x 24 1/4" STAINLESS STEEL FINISH

TAG TYPE MANUFACTURER MODEL PROVIDER QTY SIZE KEY NOTES

NEW EQUIPMENT LEGEND

RAISED ACCES FLOOR

2' - 8"

(E) MICROWAVE

(N) BASE CABINETS -

CABINETS TO ACCOMODATE

MISC. STORAGE INCLUDING

BUT NOT LIMITED TO

BINDERS, OFFICE SUPPLIES,

BREAK AREA SUPPLIES, ETC

(E) COFFEE MAKER

(E) WINDOW (E) UNDER COUNTER

REFRIGERATOR

PT1

RB1

12" 36" 36" 36"

PT1

(N) UPPER CABINETS TYP. WITH

ABBILITY TO PROVIDE

EXTERNAL LOCK.

CABINETS TO ACCOMODATE

MISC. STORAGE INCLUDING

PERSONAL BELONGINS. SEE

OYA-600 FOR MORE INFO.

15" 15" 18" 24"15"15"15"

RAISED ACCES FLOOR

2' - 8"

(N) KEY

BOX

(N) BASE CABINETS -

CABINETS TO ACCOMODATE

MISC. STORAGE INCLUDING

BUT NOT LIMITED TO

BINDERS, OFFICE SUPPLIES,

BREAK AREA SUPPLIES, ETC

(N) INSTANT HOT

WATER DISPENSER

(E) COFFEE MAKER

(N) FLAT SCREEN

MONITORS. FOLLOW

MFR RECOMENDATIONS

FOR MOUNTING AND

BLOCKING

(N) DESK/CHAIR WITH

IT RACK UNDER TO

ACCOMODATE (4) CPU

+ POSSIBLE

EXPANSION

PT1

RB1

PT1

PT1

102A

(N) UPPER CABINETS TYP.

WITH ABBILITY TO PROVIDE

EXTERNAL LOCK.

CABINETS TO ACCOMODATE

MISC. STORAGE INCLUDING

PERSONAL BELONGINS BUT

NOT LIMITED TO BINDERS,

OFFICE SUPPLIES, BREAK

AREA SUPPLIES, ETC

RAISED ACCES FLOOR

2' - 8"

A V

G S

T A

N D

IN

G

E Y

E H

E

IG

H T

S E

A T

E D

E Y

E H

E

IG

H T

A

V G

A P

P R

O X

/8

(N) WINDOWS WITH

ONE-WAY FILM AND

BLINDS. SILL

LOWERED TO JUST

ABOVE RAF. REFER

TO DETAIL SHEET

OYA-600 FOR MORE

INFORMATION

(R) SECURITY

EQUP. BOARD

(N) DESK/CHAIR WITH

IT RACK UNDER TO

ACCOMODATE (4) CPU

+ POSSIBLE

EXPANSION

PT1

RB1RB1

(N) ELECTRIC

MOTOR SUN

SHADE AT (E)

WINDOW

(N) MONITORS.

FOLLOW MFR

RECOMENDATIONS

FOR MOUNTONG

AND BLOCKING

WF1

WF1

18 1/4" 44

PT1 (R) FIRE

ALARM.REFER

TO MEP

DRAWINGS

FOR MORE

INFORMATION

RAISED ACCES FLOOR

2' - 8"

(N) FLAT SCREEN

MONITORS ON WALL

MOUNT ABOVE

WINDOW

(E) WINDOWS

(N) ACOUSTIC

CEILING @ 8'-0"

ABOVE RAF

(N) DESK/CHAIR WITH

IT RACK UNDER TO

ACCOMODATE (4) CPU

+ POSSIBLE

EXPANSION

(R) SECURITY

EQUP. BOARD

PT1

RB1

RB1

(E) TRANSACTION

DRAWER, (N)

CUSTOM CASEWORK

BUILT TO FIT

PT1

101B

0' - 0"

FINISH FLOOR

PT1

(N) ELECTRIC

MOTOR SUN

SHADE AT (E)

WINDOW

(N) ELECTRIC

MOTOR SUN

SHADE AT (E)

WINDOW

TALL

STORAGE

CABINET

OPEN CUBBIES

OR PERSONAL

LOCKERS

RAISED ACCES FLOOR

2' - 8"

(N) MOP/BROOM

HOLDER

(N) WALL MOUNTED

WASTE BASKET.

REFER TO SHEET

OYA - 001 FOR

MOUNTING HEIGHTS

(R) PAPER TOWEL

DISPENSER REFER

TO SHEET OYA - 001

FOR MOUNTING

HEIGHTS

PT2

RB1

E Q

E Q

E Q

11 1/4"

RAISED ACCES FLOOR

2' - 8"

PT2(N) GLOW BOX.

REFER TO

SHEET OYA - 001

FOR MOUNTING

HEIGHTS

(N) TOILET SEAT

DISPENSER.

REFER TO

SHEET OYA - 001

FOR MOUNTING

HEIGHTS

(N) WALL MOUT

TRASH CAN.

REFER TO SHEET

OYA - 001 FOR

MOUNTING

HEIGHTS

(E) MIRROR

RB1

(N) MOP/BROOM

HOLDER

(R) PAPER TOWEL

DISPENSER. REFER

TO SHEET OYA - 001

FOR MOUNTING

HEIGHTS

RAISED ACCES FLOOR

2' - 8"

101A

(N) DOOR TO

ADMINISTRATION

BUILDING. REFER TO

DOOR SCHEDULE

FOR MORE

INFORMATION

(E) STAIRS. PROVIDE

NEW FINISH PANELS

IF NECESSARY AND

REUSE EXISTING

PEDESTALS

(N) NEW HANDRAIL.

WALL MOUNTED

PT1

RB1

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:06 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-500

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E

IN

T E

R

IO

R E

L E

V A

T

IO

N S

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 1/2" = 1'-0"

1 ELEVATION - CONTROL ROOM EAST

- 1/2" = 1'-0"

2 ELEVATION - CONTROL ROOM SOUTH

- 1/2" = 1'-0"

3 ELEVATION - CONTROL ROOM NORTH

- 1/2" = 1'-0"

4 ELEVATION - CONTROL ROOM WEST

- 1/2" = 1'-0"

5 ELEVATION - RESTROOM NORTH

- 1/2" = 1'-0"

6 ELEVATION - RESTROOM EAST

- 1/2" = 1'-0"

7 ELEVATION - CONTROL ROOM SOUTH 1A

A

EXISTING CMU WALL.

INFILL WITH MORTAR

AS NECESSARY.

GLASS. REFER TO

WINDOW SCHEDULE.

V

IF

GLASS. REFER

TO WINDOW

SCHEDULE.

CONTINUOUS

BEAD OF SEALANT

AND BACKER ROD,

EACH SIDE, TYP.

CONTINUOUS BEAD OF

SEALANT AND BACKER

ROD, EACH SIDE, TYP.

SHIM AS NECESSARY

EXISTING

CMU WALL

EXTERIOR

EXTERIOR

CONTROL

ROOM

REMOVABLE 12 GA. 1-1/4"

ANGLE, STL. STOP,

SECURE TO FRAMES AS

SPECIFIED

1 1/4"0' - 2"

/2

HM FRAME FILL SOLID

WITH RIGID INSUL.,

PAINT; TYP. REFER TO

WINDOW SCHEDULE

VIF

/4

7 1/2"

CONTROL

ROOM

REMOVABLE 12 GA. 1-1/4"

ANGLE, STL. STOP,

SECURE TO FRAMES AS

SPECIFIED

B

HM FRAME FILL SOLID

WITH RIGID INSUL.,

PAINT; TYP. REFER TO

WINDOW SCHEDULE

SHIM AS NECESSARY

/4

3 1/4"

REFER TO PLAN

FOR DOOR SWING

HOLLOW METAL DOOR

AND DOOR FRAME

REFER TO DOOR SCHEDULE

CONTINUOUS BEAD OF SEALANT

AND BACKER ROD, EACH SIDE, TYP.

EXISTING CMU WALL

SHIM AS NECESSARY

6"

A T

J A

M B

A T

H E

A D

GALV METAL

DRIP EDGE

INTERIOR

EXTERIOR

STEEL LINTEL INVERTED 'T' TYPE

SHOWN, OTHER STEEL LINTELS ALSO

ACCEPTABLE

/4

/4

FILL SOLID WITH NON-SHRINK GROUT

CONTROL JOINT SEE SPECIFICATIONS

HOLLOW METAL DOOR

AND DOOR FRAME

REFER TO DOOR SCHEDULE

CONCRETE FLOOR SLAB

REFER TO FINISH SCHEDULE

ALUMINUM THRESHOLD SET IN SEALANT

PROVIDE CLOSURE AT ENDS, TYP.

CMU/CONCRETE WALL

BEYOND

INTERIOREXTERIOR

RAISED ACCES FLOOR

2' - 8"

SS1

LT1

12" 36" 36"

/4

(N) BASE

CABINETS TO

ACCOMODATE

MISC. STORAGE

INCLUDING BUT

NOT LIMITED TO

BINDERS, OFFICE

SUPPLIES, BREAK

AREA SUPPLIES,

ETC

(N) BASE CORNER

CABINET WITH SINK

LT1

36"84"

/2

(N) UPPER CABINETS

TYP. PROVIDE KEYED

CAM LOCK ON ALL

WALL CABINETS EXEPT

CORNER CABINET.

CABINET TO

ACCOMODATE MISC.

PERSONAL BELONGINS

4" BAR HANDELS.

STAINLESS

STEEL FINISH

CAM LOCK

KEYED

LT1

15" 15" 18" 24"15"15"15"

12"

24"

(N) UPPER CORNER

CABINET

RAISED ACCES FLOOR

2' - 8"

(N) BASE CORNER

CABINET WITH

SINK LT1

/4

36" 23"

OPEN

SS1

(N) BASE CABINETS -

CABINETS TO

ACCOMODATE MISC.

STORAGE

INCLUDING BUT NOT

LIMITED TO BINDERS,

OFFICE SUPPLIES,

BREAK AREA

SUPPLIES, ETC

3/4" END

PANEL, LT1

24"

(N) UPPER CABINETS TYP.

PROVIDE KEYED CAM LOCK

ON ALL WALL CABINETS

EXEPT CORNER CABINET.

CABINETS TO ACCOMODATE

MISC. PERSONAL

BELONGINGS. SEE OYA-600

FOR MORE INFO.

(N) UPPER

CORNER CABINET

CAM LOCK

KEYED 4" BAR HANDLES.

STAINLESS STEEL

FINISH.

LT1

/4

18" 15"

21 1/2"

12"

24"

/2

3"

/4

SS1

LT1

/2

2' - 6"

(E)

HANDRAIL

(E) TRANSACTION

DRAWER, (N)

CUSTOM CASEWORK

BUILT TO FIT

(E)

WALL

/4

24"

V

IF

/2

SS1

LT1

(E) TRANSACTION

DRAWER

(E) WINDOW

(N) CUSTOM

CASEWORK BUILT TO

FIT. CONTRACTOR

TO VERIFY IN FIELD

PASS THROUGH

OPENING

DIMENSIONS.

(E) CMU WALL

VIF

3"

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:06 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

D3482000

M K

J

A M

K J

A J B

J B

OYA-600

O R

E G

O N

Y O

U T

H A

U T

H O

R

IT

Y E

A S

T E

R N

O R

E G

O N

F A

C

IL

IT

Y

EASTERN OREGON FACILITY

1800 W MONROE ST

BURNS, OR 97720

PORTLAND OFFICE

PORTLAND, OR 97201

2020 SW 4TH AVE, SUITE 300

A R

C H

IT

E

C T

U R

E D

E T

A

IL

S

/1

/2

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

N

- 1 1/2" = 1'-0"

7 WINDOW JAMB & SILL, TYP.

- 1 1/2" = 1'-0"

1 HM DOOR DETAIL @ CMU WALL, TYP.

- 1 1/2" = 1'-0"

2 HM DOOR SILL @ CMU WALL SILL, TYP.

- 1/2" = 1'-0"

3 BREAK AREA CABINETS EAST VIEW

- 1/2" = 1'-0"

4 BREAK AREA CABINETS SOUTH VIEW

- 1/2" = 1'-0"

5 TRANSACTION DRAWER FRON VIEW

- 1/2" = 1'-0"

6 TRANSACTION DRAWER SIDE VIEW

1. VERIFY ALL EXISTING DOOR SIZES, DISCREPANCIES WITH SCHEDULE

SHOULD BE NOTED AND REVIEWED WITH ARCHITECT.

2. HARDWARE SCHEDULE HAS BEEN DEVELOPED FOR DESIGN INTENT ONLY.

HARDWARE PROVIDER IS RESPONSIBLE FOR VERIFYING THE FUNCTION AND

COMPATIBILITY OF ALL COMPONENTS.

3. UNLESS OTHERWISE NOTED, THE HEIGHT OF DOOR HARDWARE HANDSETS

ARE TO MATCH ADJACENT EXISTING HARDWARE.

4. DOOR HARDWARE TO BE COMPLETE IN ORDER TO FUNCTION AS

DESCRIBED IN THESE NOTES, SCHEDULES AND SPECIFICATIONS

5. PROVIDE ALL HARDWARE ACCESSORIES NOT LIMITED TO HINGES,

ASTRAGALS, BOLTS, AUTOMATIC BOLTS, FLUSH BOLTS, AUTOMATIC FLUSH

BOLTS, SMOKE SEALS, COORDINATORS, LOCK SETS, LATCHES, LEVERS

STRIKE PLATES, CLOSERS, KEYS CYLINDERS, STOPS, FLOOR AND WALL

STOPS, SILENCERS, BOTTOMS, SADDLES, TRIM, KICK PLATES, ETC. REFER

TO SPECIFICATIONS.

6. PROVIDE ELECTRIC CAPABILITY FOR DOOR CONTACTS, ACCESS CONTROL,

READERS, ELECTRIC HINGES AND ANY OTHER ELECTRIC REQUIREMENT TO

SATISFY THE FUNCTION OF THE DOORS AS DESCRIBED IN THESE NOTES,

SCHEDULES AND SPECIFICATIONS.

7. SECURITY INTEGRATOR TO INSTALL CARD READER HARDWARE. GC IS

RESPONSIBLE FOR COORDINATING AND INSTALLATION OF HARDWARE WITH

SECURITY AND ELECTRICAL REQUIREMENTS FOR DOORS. GC IS

RESPONSBILE FOR PROVIDING POWER & PATHWAYS AS NEEDED.

8. ALL DOORS AND FRAMES TO BE FACTORY PREPPED TO RECEIVE INTENDED

DOOR HARDWARE, RATED DOORS TO MAINTAIN FIRE RATING.

9. ARCHITECT IS NOT RESPONSIBLE FOR KEYING REQUIREMENTS. GC IS

RESPONSIBLE FOR PROCURING AND INSTALLING ALL CORES & LOCKSETS.

GC TO COORDINATE WITH OWNER'S PM AND BUILDING FACILITIES FOR

KEYING REQUIREMENTS.

10. LOCATION OF DOOR IS DETERMINED BY THE DOOR NUMBER, EXAMPLE:

101A (ROOM NUMBER- 101 DOOR- A).

11. SEE SPECIFICATION 08 34 60 DETENTION DOORS AND FRAMES, 08 71 00

DOOR HARDWARE, 08 80 00 GLAZING AND 08 51 00 METAL WINDOWS FOR

MORE INFORMATION.

WINDOW, DOOR & HARDWARE GENERAL NOTES:

A C

O U

S T

IC

A

L C

E

IL

IN

G

T

IL

E

G

R

ID

ACT 1

GRID

MANUFACTURER

MODEL

NUMBER / SIZE

COLOR

REMARKS

CLASSIFICATION

MANUFACTURER

STYLE NAME

NUMBER / SIZE

COLOR

AMSTRONG

CALLA

24" X 24"

BLACK

@ CONTROL ROOM

CLASS A

AMSTRONG

INTERLUDE XL

9/16"

BLACK

F L

O O

R

VCT1

AFP1

MANUFACTURER

MODEL

NUMBER / SIZE

COLOR

REMARKS

MANUFACTURER

MODEL

SIZE

TARKETT

12" X 12"

CORTINA GRANDE - BLACK & WHITE

@ RESTROOM / CONTROL ROOM

TATE

STONEWORKS DECORATIV CONCRETE

ACCESS FLOOR PANEL

24" X 24"

FINISH MIDNIGHT

R E

S

IL

IE

N

T B

A S

E

RB1

MANUFACTURER

MODEL

NUMBER / SIZE

COLOR

REMARKS

NOTES

FLEXCO

4"

BLACK

@ RESTROOM / CONTROL ROOM

RUBBER, STRAIGHT

P A

IN

T

PT1

MANUFACTURER

FINISH

NUMBER

COLOR

NOTES

SHERWIN WILLIAMS

SNOWBOUND

@ CONTROL ROOM

EGGSHELL

SW 7004

PT2

MANUFACTURER

FINISH

NUMBER

COLOR

NOTES

SHERWIN WILLIAMS

SNOWBOUND

@ RESTROOM

SATIN

SW 7004

PT3

MANUFACTURER

FINISH

NUMBER

COLOR

NOTES

SHERWIN WILLIAMS

MATCH WITH EXISTING HM FRAMES

@ HM FRAMES

SEMI - GLOSS

TBD

S O

L

ID

S

U R

F A

C E

SS1

MANUFACTURER

FINISH

SIZE

NOTES

CORIAN

1 1/4"

@ COUNTERTOP

SPARKLING GRANITA

R E

S

IL

IE

N

T B

A S

E

RB1

MANUFACTURER

MODEL

NUMBER / SIZE

COLOR

REMARKS

NOTES

FLEXCO

4"

BLACK

@ RESTROOM / CONTROL ROOM

RUBBER, STRAIGHT

W

IN

D O

W F

IL

M

WF1

MANUFACTURER

MODEL

NUMBER / SIZE

COLOR

NOTES

3M

@ CONTROL ROOM

PRIVACY FILM (ONE-WAY)

F

IN

IS

H

LT1

MANUFACTURER

MODEL

NUMBER / SIZE

COLOR

NOTES

FORMICA

@ CABINETS

FINISH OAK

ABS ABS PLASTIC

AL ALUMINIUM

(E) EXISTING

FGR FIRE RATED CERAMIC GLASS

FACT FACTORY FINISH

GL GLASS

HM HOLLOW METAL

MIN MINUTE

MATL MATERIAL

LSS LIFE SAFETY SYSTEM

NR NOT RATED

N/A NOT APPLICABLE

P PAINT

PT PAINTED FINISH

PR PAIR

(R) RELOCATED

SIM SIMILAR

STL STEEL

TEMP TEMPERED

SS STAINLESS STEEL (304 or 316? brushed finish?)

WD WOOD

WG WIRE GLASS

VN VENEER

DOOR SCHEDULE ABBREVIATIONS:

1. BY MANUFACTURER

2. PANIC HARDWARE

3. 90° SWING

4. 180° SWING

5. CARD READER

6. PROVIDE AUTOMATIC DOOR OPERATOR AND DOOR

ACTUATORS.

7. ELECTRIFIED HARDWARE FOR FUTURE USE.

8. CARD ACCESS CONTROLLED W/ADJACENT DOOR.

9. DOOR IS PART OF GLAZING ASSEMBLY. HARDWARE,

PULLS, AND HINGES PROVIDED BY GLASS VENDOR.

10. DOOR TYPE TO MATCH EXISTING.

11. FIRE-RATED 90 MIN.

DOOR SCHEDULE KEYNOTES:

HM FRAME TYPE

2" 2"

SEE DOOR

SCHEDULE

S E

E D

O O

R S

C H

E D

U L E

HM FRAME

PAINT, TYP.

REFER TO

FINISH

SCHEDULE

HM WINDOW ELEVATION

DESCRIPTION:

FIXED

S E

E W

IN

D

O W

S C

H E

D U

L E

SEE WINDOW SCHEDULE

2"TYP.

1 3/8" SECURE-

TEM+POLY(SP035).

REFER TO

MANUFACTURER

SPEC FOR MORE

INFORMATION

HM FRAME

PAINT, TYP.

REFER TO

FINISH

SCHEDULE

OYA-600

Sim

OYA-600

Sim

HM FRAME TYPE

6" 2"

SEE DOOR

SCHEDULE

S E

E D

O O

R S

C H

E D

U L E

HM FRAME

PAINT, TYP.

REFER TO

FINISH

SCHEDULE

1A

(2) 1/2 DIM.

CONDUIT FOR

LOCK POWER AND

CONTROL; WELD

INTO FRAME,

EXTEND 6" ABV.

TOP OF FRAME;

SEE ELECT

A B C

FLUSH PANEL FULL VISION LIGHT

PANEL

NARROW LIGHT

VISION PANEL -

TEMP. GLASS

6" 6"

S E

E D

O O

R S

C H

E D

U L E

SEE DOOR SCHEDULE

S E

E D

O O

R S

C H

E D

U L E

SEE DOOR SCHEDULE

S E

E D

O O

R S

C H

E D

U L E

SEE DOOR SCHEDULE

/2

/2

8" 6 1/2"

S E

E D

O O

R S

C H

E D

U L E

SEE DOOR SCHEDULE

4" x 25"

CLEAR

OPENING

/2

/2

8" 6 1/2"

S E

E D

O O

R S

C H

E D

U L E

SEE DOOR SCHEDULE

4" x 25"

CLEAR

OPENING

.970" SECURE-

TEM+POLY(SP028).

REFER TO SPEC 08 80 00

FOR MORE INFORMATION

Date:

Proj. No.:

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

PLOT DATE/TIME:

Drawing No.:

P ro je c t T it le

D ra w in g T it le

D

C

B

A

1 2 3 4 5 6

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

www.Jacobs.com

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

12/10/2022

11/29/2023 8:57:07 AM BIM 360://US_D3482000_OYA Control Room Upgrade/Eastern_OYA-Control-Room-Upgrade-ARCH.rvt

IS

S

U E

F O

R C

O N

S T

R U

C T

IO

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .