This document is Attachment 9 - Prototype Testing Outline, detailing comprehensive testing requirements for small arms weapons and ammunition prototypes across multiple ammunition types and configurations.
The testing outline specifies weapon system testing requirements across 15 weapons with approximately 15,865 total rounds for Training Round ammunition, 830 rounds for Counter Defilade Round, 470 rounds for Close Quarters Battle Round, 15 primed cases, and 600 rounds for Counter-UAS Round. Weapon testing includes inspection, parts interchange, zero repeatability, zero retention, recoil, kinematics, and reliability/durability evaluations (3,000-8,100 rounds per test category). Performance testing encompasses firing table ballistic matching, operational temperature extremes (125°F to -25°F), environmental conditions (thermal shock, altitude, solar radiation, dust, humidity, rain, immersion, and salt fog), and mechanical stress testing (1.5-meter concrete drops). Ammunition testing covers 680 total rounds for Training, 1,165 for Counter Defilade, 710 for Close Quarters Battle, and 1,285 for Counter-UAS variants, including dispersion, sequential rough handling, electronic pressure/velocity/action time measurement, airburst accuracy, fuze testing (arming, graze sensitivity, impact safety, point detonation), and long-term storage evaluation. Fire control system testing requires evaluation of 24 units across optical performance (field of view, magnification, resolution, transmittance), laser capabilities (visible and infrared aiming lasers), ranging and ballistic computation, environmental durability, electromagnetic effects, system reliability, and various mounting and operational characteristics. All testing will be performed in accordance with Test Operations Procedure 03-2-045A for Small Arms weapons and ammunition, with all test quantities noted as approximations subject to change.
View the file
Other files
Show all 39
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Training Round
Counter Defilade Round
Close Quarters
Battle Round
Primed Cases
Counter-sUAS Round
Training Round
Counter Defilade Round
Close Quarters
Battle Round
Prined Cases
Counter-sUAS Round
Inspection 12 35 0 0 0 0 420 0 0 0 0 Parts Interchange 12 35 0 0 0 0 420 0 0 0 0 Zero Repeatability 3 0 0 0 0 0 0 0 0 0 0 Zero Retention 1 370 0 0 0 0 370 0 0 0 0 Recoil 1 5 5 5 0 5 5 5 5 0 5 Kinematics 1 15 15 15 0 15 15 15 15 0 15 Reliability/Durability 3 2700 100 100 0 100 8100 300 300 0 300 Firing Table - Ballistic Match 1 165 120 0 0 120 165 120 0 0 120 High Temperature Operational (125 F) 2 915 15 15 0 15 1830 30 30 0 30 Extreme (160 F) 1 20 15 15 0 20 20 15 15 0 20 Low Temperature Operational (0 F) 2 1395 15 15 0 15 2790 30 30 0 30 Extreme (-25 F) 1 20 15 15 0 20 20 15 15 0 20 Ricochet 1 250 0 0 0 0 250 0 0 0 0 Attitudes 1 40 40 40 0 40 40 40 40 0 40 Noise 1 10 0 0 0 0 10 0 0 0 0 Toxic Fumes 1 10 10 10 0 10 10 10 10 0 10 Flash 1 10 10 10 0 10 10 10 10 0 10 Unlubricated 2 320 0 0 0 0 640 0 0 0 0 Thermal Shock 2 30 10 0 0 0 60 20 0 0 0 Altitude 2 30 10 0 0 0 60 20 0 0 0 Solar Radiation 2 30 10 0 0 0 60 20 0 0 0 Dust 2 50 25 0 0 0 100 50 0 0 0 Wet Mud 2 15 0 0 0 0 30 0 0 0 0 Dry Mud 2 15 0 0 0 0 30 0 0 0 0 Humidity 2 40 20 0 0 0 80 40 0 0 0 Rain 1 120 0 0 0 0 120 0 0 0 0 Fresh Water Immersion 3 30 10 0 0 0 90 30 0 0 0 Salt Fog 3 40 20 0 0 0 120 60 0 0 0 1.5-m (5ft) Drop onto Concrete 3 0 0 0 5 0 0 0 0 15 0 Chemical Compatibility Coupons Only 0 0 0 0 0 0 0 0 0 0
TP CD CQB Primed Cases C-UAS
TOTALS: 15865 830 470 15 600
NOTE: All tests will be performed in general accordance with Test Operations Procedure 03-2-045A Small Arms - Hand and Shoulder Weapons and Machine Guns. All tests, test methods, and quantities are approximations and are subject to change.
Subtest Number of Weapons
Quantity of Ammunition per Weapon Total Rounds
Attachment 9 - Prototype Testing Outline
Training Round
Counter Defilade Round
Close Quarters
Battle Round
Counter-sUAS Round
Training Round
Counter Defilade Round
Close Quarters
Battle Round
Counter-sUAS Round
Dispersion 5 0 60 0 60 0 300 0 300 0 Sequential Rough Handling 1 0 320 320 320 320 320 320 320 320 Electronic Pressure, Velocity, and Action Time (EPVAT)
0 2 50 50 50 50 50 50 50 50
Airburst Accuracy 5 0 0 100 0 100 0 500 0 500 Fuze Arming 1 0 5 90 0 90 5 90 0 90 Fuze Graze Sensitivity 1 0 0 100 0 100 0 100 0 100 Fuze Impact Safety 1 0 0 5 0 5 0 5 0 5 Point Detonation 1 0 0 60 0 60 0 60 0 60 Long-Term Storage 1 0 5 40 40 40 5 40 40 40 C-sUAS Targets (Sphere) 1 0 0 0 0 120 0 0 0 120
TP CD CQB C-UAS
TOTALS: 680 1165 710 1285
NOTE: All tests will be performed in general accordance with Test Operations Procedure 03-2-045A Ammunition Small Arms. All tests and quantities are approximations and are subject to change.
Subtest Number of Weapons
Quantity of Ammunition per Weapon Total Rounds
Number of
EPVAT
Barrels
Inspection 24 Ranging Capability with FWS-I 1 LRF Accuracy 3 Objective Interface 1 0.9-m (3 ft) Drop onto Dirt 3 Laser Filter Unit 1 Field of View 3 Anti-Reflection Device 1 Diopter Adjustment 3 Remote Mountable 1 Diopter Uniformity and Retention 3 Interconnection 1 Exit pupil 3 Communication Port / Wired Port 1 Clear Eye Distance 3 Maintenance Cable 1 Target Focus 3 Wireless Transmission Distance 3 Magnification 3 Network Configuration 3 Modulation Transfer Function 3 Network Association 3 Resolution Limit 3 Sensors Inclination Angle 3 Transmittance 3 Sensors Optical Coatings (Need Samples) 3 Cant Angle 3 Veiling Glare 3 Temperature 3 Passive Reticle Focal Plane 1 Barometric Pressure 3 Passive Reticle Surface Quality 3 Humidity 3 Elevation / Windage Adjustment Range 3 Power Source 1 Reticle Cant 3 Reverse Polarity Protection 1 Display Zones 1 Battery Orientation Marking 1 Dynamic Reticle 1 Battery Compartment Cover 1 Dynamic Reticle Focal Plane 1 Battery Replacement 1 Diopter Reticle Offset 3 Battery Level Monitor 1 Eye Box 3 Battery Run Time (all temps) Visibility 3 Ambient (70 F) 3 Luminance Degradation 3 Operational Hot (125 F) 3 Display Burn-in 3 Extreme Hot (160 F) 3 Response Time 3 Operational Cold (0 F) 3 LRF Ranging Capability 3 Extreme Cold (-25 F) 3 Beam Divergance 3 Software Standby Mode Inactivity 3 Wavelength 3 Start-Up/Wake-Up Time 3 Range Accuracy 3 System Updates 1 False Alarm 1 Ballistic Solver Computation Time 3 Adjustment Range 3 Target Reference Points 1 Coded Spot Tracking 3 System Accuracy - Reticle Boresight Error 3 Laser Safety 1 Reticle Calibration Error 3 Visible Laser Parallax Error 3 Visible Aiming Laser Capability 3 Magnification Switch Adjustment Error 3 Beam Divergence 3 Applied Forces 3 Wavelength 3 LRF Error Boresight 3 Output Power and Irradiance 3 Boresight Repeatability (Reattachment) 3 Laser Safety 3 Boresight Retention (Gunfire Pyroshock)* 3 Laser Activation 3 Low Pressure (High Altitude) 3 Infrared Aiming Laser Operational Temperature 5 Aiming Laser Capability 3 Storage Temperature 3 Beam Divergence 3 Temp Shock 3 Wavelength 3 Solar Radiation 3 Output Power and Irradiance 3 Transportation and Vibration 3 Laser Safety 1 Humidity 3 Laser Activation 3 Salt Fog 3 Lens Protection 1 Immersion 5 Operational Torque 3 Transport Drop 3 Glint Suppression 3 Optical Quality and Cleanliness 3 Size (length, height, width) 1 Gunfire During Rain* 3 Surface finish 3 Chemical Compatibility Coupons Only Color 3 Dust* 3 NIR Reflectance 3 Electromagnetic Effects 2 Transport Case (if available) 1 System Reliability* 3 Mount 1 Detectable Emissions 3 Operating Orientation 1 Material 1 Captive Mounting Hardware 1 Workmanship 3 Interference 1 Marking 1 Ballistic Laser Protective Spectacles 1 Cooperative Vulnerability Identification 1 Optical Center Line 1 3D Print 1
NOTE: All tests and quantities are approximations and are subject to change.
*Conducted during Weapon testing
Subtest Number of Fire Controls Subtest