Attachment 14- Ammo Packaging Drawings.pdf

PDF 6 MB Posted

Attached to
Precision Grenadier System Prototype Project Opportunity (PPON)
Solicitation number
W15QKN-26-R-1BH5
Issued by

About this file

This document is a comprehensive federal procurement specification for unitization procedures for boxed ammunition and components on 4-way entry pallets, issued by the U.S. Army Materiel Command.

The basic procedures drawing (19-48-4116, Revision 14, December 2019) establishes standard specifications for assembling ammunition unit loads on pallets for storage and shipment. The document covers general notes and material specifications including pallet requirements (MIL-DTL-15011; 4-way entry, Style 1, 1A, or 1B), steel strapping (ASTM D3953; flat strapping Type 1, heavy duty, grades 2-3, sizes 3/4" x .035"/.031"/.029" or 1-1/4" alternative), and seal/staple specifications. Key procedures include positioning ammunition boxes centered on pallets, applying load straps through pallet slots or pre-positioned on deck, installing horizontal and tiedown straps with proper tensioning to cut into box edges, and using filler assemblies or empty boxes to complete full layers. Unit loads must not exceed 4,000 pounds gross weight and should conform to dimension standards of 44" length by 54" width (for Style 1 pallets). The document permits less-than-full-layer configurations using filler assemblies, empty boxes (maximum four per unit), or light boxes (maximum two per unit). Multiple appendices (5C for 5.56mm cartridges; 26H and 26S for 40mm cartridges; 21 for 40mm PA120 containers) provide specific unitization configurations with bill-of-materials, pallet unit data charts, and assembly details. A companion drawing (19-48-4232, Revision 2, March 2005) covers unitization procedures for ammunition packed in metal or plastic boxes on 4-way entry metal pallets, establishing similar strapping and assembly standards applicable to various ammunition items.

View the file

Other files

File Type Posted
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026MAY29.docx DOCX document
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026MAY27.docx DOCX document
PGE PPON Updated 20MAY2026.docx DOCX document
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026MAY19.docx DOCX document
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026MAY18.docx DOCX document
Attachment 15 - PGS Model OTA DRAFT Updated 2026MAY07.docx DOCX document
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026MAY11.docx DOCX document
PGS PPON Updated 28APR2026.docx DOCX document
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026APR30.pdf PDF
Attachment 17 - Ammunition Sample SLA.docx DOCX document
Attachment 16 - Fire Control Sample SLA.docx DOCX document
Attachment 18 - Weapons Sample SLA.docx DOCX document
Attachment 4 - Pricing Updated 14APR2026.xlsx XLSX spreadsheet
Attachment 15 - PGS Model OTA DRAFT Updated 14APR2026.docx DOCX document
PGS PPON Updated14APR2026.docx DOCX document
Attachment 3 - Delivery Schedule Updated 14APR2026.pdf PDF
Attachment 9 - Protoype Testing Outline Updated 14APR2026.pdf PDF
W15QKN-26-R-1BH5 PPON PGS QandAs - 2026APR17.docx DOCX document
W15QKN-26-R-1BH5 PPON PGS Questions and Answers - 2026APR13.pdf PDF
Attachment 21- Accounting System Questionnaire.pdf PDF
DD Form 2345 - Militarily Critical Technical Data Agreement.pdf PDF
AMSTA-AR 1350 - Data Request Questionnaire.pdf PDF
Non-Disclosure Non-Use Agreement.docx DOCX document
Attachment 19 - Business Status Certification.pdf PDF
Attachment 11 - Security Information Requirements.pdf PDF
Attachment 9 - Prototype Test Outline.pdf PDF
Attachment 3 -Delivery Schedule.pdf PDF
Attachment 7 - User Acceptance.pdf PDF
Attachment 17 - Ammunition - Sample SLA.pdf PDF
Attachment 16 - Fire Control - Sample SLA.pdf PDF
Attachment 8_Weapons_Ammo_FC TDP Worksheet.pdf PDF
Attachment 18 - Weapons Sample SLA.pdf PDF
Attachment 15 - PGS Model OTA DRAFT 23JAN2026.docx DOCX document
Attachment 10 - Available Maintenance Tools.pdf PDF
PGS PPON Final 01APR2026.pdf PDF
Attachment 12 - Mount Drawings.pdf PDF
Attachment 5_ICD TDP Worksheet.pdf PDF
Attachment 6 -Operational Effectiveness.pdf PDF
Attachment 4 - Pricing .xlsx XLSX spreadsheet
Show all 39

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

B

A

D

C

B

A

8 7 6 5 4 3 12

DESIGN ACTIVITY

SIZE CAGE CODE

SCALE UNIT WT.

DRAWN BY DATE(YEAR-MO-DA)

CHECKER ENGINEER

ENGINEER QUALITY ENGINEER

DRAWING APPROVAL

DESIGN APPROVALMATL ENGR MODELED BY

CONTRACT NUMBER

CONTRACTOR

SHEET

DRAWING SIZE D

TOLERANCES ON ANGLES �# �$

2 PLACE DECIMALS �#

3 PLACE DECIMALS �#

FORMAT: D_TACOM_ENG_1_0 12345678

DWG NO.

7 1/2

MAX

12 1/32 MAX

6 3/32 MAX

NOTE 4

WHEN BOX IS ASSEMBLED WITH COVER CLOSED

BODY HINGE SHALL BUTT AGAINST COVER HINGE

WITH CENTER LINE OF BODY COINCIDING WITH

CENTER LINE OF COVER.

REVISIONS

APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONDRAWING REVMODEL REV

BMG2012-07-26

PRODUCT BASELINE

ERR R12K2024

1 OF 1 3/4

1303254219200D

BOX, AMMUNITION,

M2A2 ASSEMBLY

US ARMY

ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER

PICATINNY ARSENAL, NEW JERSEY 07806-5000

2012-07-25T. CORADESCHI

2012-07-25J. RUNELL

J. SLIKER

2011-10-13A.Z.

APPLICATION

USED ONNEXT ASSY

SEE ENGINEERING RECORDS

FINAL

PMIC

MECHANICAL

PROPERTIES

YP

TS

EL2

RA

BH

RH A. ZIOBRO

THIRD ANGLE PROJECTION

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

DO NOT SCALE DRAWING

PART NO. 13032542

THIS DRAWING WAS GENERATED FROM A SOLID MODEL

AND IS CAD MAINTAINED. CHANGES SHALL BE

INCORPORATED BY THE DESIGN ACTIVITY.

NSN NONE

REMARKSNOMENCLATURE

OR DESCRIPTION

PART NO. OR

IDENTIFYING NO.

CAGE

CODE

QTY.

REQ.

ITEM OR

FIND NO.

BODY ASSEMBLY, M2A2130325481920011

COVER ASSEMBLY, M2A2130325491920012

NOTES

1. APPLICABLE STANDARDS/SPECIFICATIONS:

A. ASME Y14.5M-1994

B. MIL-A-2550

C. MIL-DTL-3060

2. GASKET REQUIREMENTS:

.090�#.020 COMPRESSION OF GASKET WHEN CLOSED.

3. ANY PAINT DAMAGE PRIOR TO OR DURING THIS ASSEMBLY MUST BE RETOUCHED

TO MAINTAIN A 1.0 MIL THICKNESS OF PAINT, DRAWING 9347108 (SEE NOTE 5).

4. AN ADDITIONAL 1/64 INCH TOLERANCE PER SIDE MAY BE ADDED TO COVER

WIDTH AT CORNERS. TOLERANCE TO EXTEND FOR 1/2 INCH FROM CORNER.

5. IF ALTERNATE PAINT IS USED, TOUCH UP ANY DAMAGED PAINT AREAS

USING COMPATIBLE PAINT IN THE PROPER THICKNESS AS APPROVED

BY THE CONTRACTING OFFICER.

DISTRIBUTION STATEMENT A.

APPROVED FOR PUBLIC RELEASE:

DISTRIBUTION IS UNLIMITED.

FRACTIONS �# 1/16

INSIDE DIMENSIONS

11+1/32 X 5 9/16+1/64 X 6 25/32+1/64

SCALE 1/2

A

B

C

D

E

F

A

B

C

D

E

F

8 7 6 5 4 3 2 1DRAWING SIZE F

SIZE CAGE CODE

SCALE SHEET

FORMAT: F_TACOM_ENG_1_0

UNIT WT.

DESIGN ACTIVITYCONTRACT NUMBER

CONTRACTOR

DRAWN BY DATE (YEAR-MO-DA)

CHECKER ENGINEER

ENGINEER QUALITY ENGINEER

DRAWING APPROVAL

DESIGN APPROVAL

THIRD ANGLE PROJECTION

MATL ENGR MODELED BY

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN INCHES

TOLERANCES ON ANGLES

2 PLACE DECIMALS

3 PLACE DECIMALS

PMIC

12345678

DWG NO.

BMG2005-02-11NOR R04K2022 / 2005-01-31E

RLV2015-10-29NOR R15A2030 / 2015-10-27F

10.39 MAX

18.76 MAX

6.36 MAX

REVISIONS

APPROVEDDATE(YEAR-MO-DA)DESCRIPTIONDRAWING REV

RLV1994-04-28NOR M4K2001 / 1994-02-02B

RLV2001-08-29NOR R1K2052 / 2001-08-10C

HJS2002-04-15NOR R2K2002 / 2002-03-14D

NAS2022-02-17NOR R21K2033 / 2022-01-28G

1 OF 1 1/1

1256441419200F

CONTAINER, SHIPPING

AND STORAGE CARTRIDGE,

40MM, PA12

US ARMY

ARMAMENT RESEARCH, DEVELOPMENT AND ENGINEERING CENTER

PICATINNY ARSENAL, NEW JERSEY 07806-5000

JWS 1987-11-01

C. MORRISON

L. DULISSE

J. ZOLL 2005-01-31

T. FITZGERALD 2005-01-31

DO NOT SCALE DRAWING

A. ZIOBRO

40MM

CARTRIDGES

NEXT ASSY USED ON

APPLICATION

MECHANICAL

PROPERTIES

YP

TS

EL2

RA

BH

RH

PART NO. 12564414

THIS DRAWING WAS GENERATED FROM A SOLID MODEL

AND IS CAD MAINTAINED. CHANGES SHALL BE

INCORPORATED BY THE DESIGN ACTIVITY.

NSN NONE

REMARKSNOMENCLATURE

OR DESCRIPTION

PART NO. OR

IDENTIFYING NO.

CAGE

CODE

QTY.

REQ.

ITEM OR

FIND NO.

BODY ASSEMBLY125644151920011

COVER ASSEMBLY125644161920012

NOTES

1. APPLICABLE STANDARDS/SPECIFICATIONS:

A. ANSI Y14.5M-1982

B. MIL-C-70842 (AR)

C. ASME Y14.100

2. FOR CLEANING AND PAINTING INSTRUCTIONS, SEE NOTES ON THE BODY AND

COVER ASSEMBLY DRAWINGS (12564415 AND 12564416, RESPECTIVELY).

TOUCH UP ANY PLACES WHERE PAINT HAS BEEN REMOVED WITH PROTECTIVE

FINISH, COLOR FOREST GREEN NO. 34079 OF FED-STD-595, IN ACCORDANCE

WITH MIL-STD-171, METHOD NO. 4.1 FOLLOWED BY 5.2 (WASH PRIMER,

SPEC DOD-P-15328) AND DRAWING 9347108.

3. GASKET COMPRESSION SHALL BE .095 .025 INCH AVERAGE.

DISTRIBUTION STATEMENT A

APPROVED FOR PUBLIC RELEASE: DISTRIBUTION IS UNLIMITED.

SCALE 1/2

APPROVED, COMBAT CAPABILITIES DEVELOPMENT

COMMAND ARMAMENTS CENTER

APPROVED, U.S. ARMY JOINT MUNITIONS COMMAND

APPROVED BY ORDER OF COMMANDING GENERAL,

U.S. ARMY MATERIEL COMMAND

U.S. ARMY DEFENSE AMMUNITION CENTER

INDEX

ITEM PAGE(S)

GENERAL NOTES AND MATERIAL SPECIFICATIONS - - - - - - - - - - - - - 2-4

TYPICAL UNITIZATION PROCEDURES - - - - - - - - - - - - - - - - - - 5-6

LESS-THAN-FULL-LAYER UNIT LOADS - - - - - - - - - - - - - - - - - - 7

DETAILS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 8

TYPICAL FILLER ASSEMBLIES - - - - - - - - - - - - - - - - - - - - - 9

WALLS.DAVID.MIC

HAEL.1154540543

Digitally signed by

WALLS.DAVID.MICHAEL.115454

Date: 2020.03.05 07:12:31 -06'00'

WARD.GINA.

M.1369379808

Digitally signed by

WARD.GINA.M.1369379808

Date: 2020.03.05 08:50:30 -06'00'

FIEFFER.LAUR

A.A.1230375727

Digitally signed by

FIEFFER.LAURA.A.1230375727

Date: 2019.12.31 08:02:11 -06'00'

SMITH.THERESA.

ANN.1009147639

Digitally signed by

SMITH.THERESA.ANN.1009147

Date: 2020.03.05 11:24:41 -06'00'

FELICIANO.AD

IN.1259200373

Digitally signed by

FELICIANO.ADIN.1259200373

Date: 2020.01.09 13:58:00 -06'00'

THOMAS.CARL.ANT

HONY.1104621372

Digitally signed by

THOMAS.CARL.ANTHONY.11046

21372 Date: 2020.01.23 06:47:00 -06'00'

PROJECT FSA 146-75 DRAWING 19-48-4116

GENERAL NOTES

A. THIS DOCUMENT HAS BEEN PREPARED AND ISSUED IN ACCORDANCE WITH AR

740-1 AND AUGMENTS TM 743-200-1 (CHAPTER 5) AND CONFORMS TO MIL-STD-

1660.

B. APPROVED SPECIFICATIONS, COVERING THE ASSEMBLAGE AND UNITIZATION OF

BOX-PACKED AMMUNITION INTO UNIT LOADS, ARE SET FORTH IN THIS DRAWING.

THIS DRAWING WILL BE CONSIDERED THE BASIC DOCUMENT FOR THE UNITIZA-

TION OF AMMUNITION ITEMS PACKED IN BOXES, EXCEPT FOR SOME RESTRICT-

ED ITEMS, SUCH AS WP FILLED AMMUNITION. THIS DOCUMENT INCLUDES MA-

TERIAL SPECIFICATIONS AND UNITIZING STANDARDS APPLICABLE TO UNITIZA-

TION, PLUS INFORMATION RELATIVE TO TYPICAL POSITIONING OF BOXES ON A

PALLET AND INSTALLATION OF UNITIZING STEEL STRAPPING. FOR TYPICAL

UNITIZATION PROCEDURES SEE PAGES 5 AND 6. ADDITIONALLY, PROCEDURES

FOR LESS-THAN-FULL-LAYER UNIT LOADS ARE DELINEATED ON PAGE 7.

C. APPENDICES PERTAINING TO THIS BASIC DOCUMENT WILL BE ISSUED SEPA-

RATELY. ALL APPENDICES, HOWEVER, ARE A PART OF THIS BASIC PROCEDURE

DRAWING. EACH APPENDIX WILL COVER THE APPROVED CONFIGURATION FOR

A UNIT LOAD, THE SPECIFIC UNITIZATION SPECIFICATIONS AND THE PERTINENT

TABULAR DATA FOR ONE ITEM OF AMMUNITION OR FOR A CATEGORY OF AM-

MUNITION ITEMS.

D. GENERALLY, UNIT LOADS SHOWN IN THE APPENDICES WILL CONFORM TO THE

STANDARDS LISTED BELOW.

1. GROSS WEIGHTS OF PALLETIZED UNIT LOADS ARE BASED ON AN OPTIMUM

WEIGHT OF 2,464 POUNDS, DUE TO MATERIAL HANDLING EQUIPMENT CON-

SIDERATIONS. UNLESS SPECIFICALLY RESTRICTED BY ANOTHER AUTHORI-

TATIVE DOCUMENT, THE MAXIMUM GROSS WEIGHT OF AMMUNITION UNIT

LOADS IS 4,000 POUNDS.

2. UNIT LOADS SHOULD NOT EXCEED 44" IN LENGTH BY 54" IN WIDTH FOR

STYLE 1 (40" X 48") PALLETS, 39" IN LENGTH BY 51-1/2" IN WIDTH FOR STYLE

1A (35" X 45-1/2") PALLETS, OR 44" IN LENGTH BY 59" IN WIDTH FOR STYLE 1B

(42" X 53") PALLETS. UNIT LOAD HEIGHT, INCLUDING PALLET HEIGHT,

SHOULD NOT EXCEED 54". ANY OR ALL OF THE STATED DIMENSIONS FOR

THE LENGTH, WIDTH OR HEIGHT OF A UNIT LOAD, HOWEVER, CAN BE IN-

CREASED OR DECREASED, DEPENDING UPON PECULIARITIES OF THE COM-

MODITY BEING UNITIZED AND IDENTIFIABLE FACTORS THAT INFLUENCE TO-

TAL COST EFFECTIVENESS THROUGHOUT THE AMMUNITION LOGISTICS SYS-

TEM.

3. THE UNIT LOAD SHOULD EITHER BE FLUSH WITH OR SLIGHTLY OVERHANG

THE PALLET ON ALL FOUR SIDES. OVERHANG IS DEFINED AS THE DISTANCE

THAT THE AMMUNITION ITEM PACKAGE(S) EXTENDS BEYOND THE EDGE OF

THE PALLET. WHEN THE EDGE OF THE AMMUNITION ITEM PACKAGE(S) DOES

NOT REACH THE EDGE OF THE PALLET, SPACER ASSEMBLIES OR BATTENS

WILL BE POSITIONED WITHIN THE UNIT LOAD IN ACCORDANCE WITH SPECIFI-

CATIONS OF THE APPLICABLE APPENDIX AND AS TYPICALLY SHOWN ON

PAGE 6. SEE GENERAL NOTE "V" ON PAGE 3.

(CONTINUED AT RIGHT)

MATERIAL SPECIFICATIONS

PALLET - - - - - - -: MIL SPEC MIL-DTL-15011; 4-WAY ENTRY, STYLE 1,

1A OR 1B, TYPE I, CLASS 1, PRESERVATIVE AND

HEAT TREATED.

LUMBER - - - - - - -: SEE TM 743-200-1 (DUNNAGE LUMBER) AND VOLUNTARY

PRODUCT STANDARD PS 20 FOR FILLER ASSEMBLIES.

ASTM D 6199; CLASS 2, GROUP II, III, OR IV,

PRESERVATIVE AND HEAT TREATED FOR OTHER DUNNAGE

ASSEMBLIES. NOTE: ONLY GROUP IV LUMBER IN AC-

CORDANCE WITH ASTM D6199 WILL BE ACCEPTABLE FOR

THE CONSTRUCTION OF THE PALLET. SEE GENERAL

NOTES "AA" ON PAGE 3 AND “JJ” ON PAGE 4.

NAILS - - - - - - -: ASTM F1667; COMMON STEEL NAIL (NLCMS OR

NLCMMS). ALT: UNDERLAYMENT NAIL (NLUL), PAL-

LET NAIL (NLPL), OR COOLER NAIL (NLCL) OF SAME

SIZE. SEE GENERAL NOTE "GG" ON PAGE 4.

PLYWOOD - - - - - -: COMMERCIAL ITEM DESCRIPTION A-A-55057, INDUS-

TRIAL PLYWOOD, INTERIOR WITH EXTERIOR GLUE,

GRADE C-D. IF SPECIFIED GRADE IS NOT AVAILA-

BLE, A BETTER INTERIOR OR AN EXTERIOR GRADE MAY

BE SUBSTITUTED.

STRAPPING, STEEL - -: ASTM D3953; FLAT STRAPPING, TYPE 1, HEAVY DUTY,

FINISH B (GRADE 2), SIZE 3/4" X .035" OR .031"

OR .029”. ALTERNATIVE SIZE 1-1/4" X .035" OR

.031" OR .029”. NOTE: IF EDGES DO NOT MEET

THE PREECE TEST FOR GRADE 2, ANY BRITE OR SLIT

EDGES MUST HAVE FINISH A OVERLAY APPLIED.

SEAL, STRAP - - - -: ASTM D3953; CLASS H, FINISH B (GRADE 2), DOUBLE

NOTCH TYPE, STYLE I, II, III, OR IV. ALTERNA-

TIVE SEAL FINISH: SIGNODE OR DELTA PAINTED

SEALS MAY BE USED AS AN ALTERNATIVE IF ALL SUR-

FACES ARE PAINTED. GRITTED BACKING IS NOT PER-

MITTED.

STAPLE, STRAP - - -: ASTM F1667; STFCS-189, STFCS-198, STFCS-207, OR

STFCS-216, 15/16" OR 1" CROWN WIDTH X 3/4" LEG

LENGTH FOR 3/4" STRAPPING OR STFCS-224,

1-17/32" CROWN WIDTH X 3/4" LEG LENGTH FOR

1-1/4" STRAPPING. SEE GENERAL NOTE “P” ON PAGE

3.

(GENERAL NOTES CONTINUED)

4. AN AMMUNITION BOX (EXTERIOR PACK) WILL NOT CONTAIN MORE THAN ONE

LOT OF AMMUNITION PER BOX. UNIT LOADS WILL NOT CONTAIN MORE THAN

TWO LOTS PER UNIT LOAD, EXCEPT WHERE REQUIRED FOR BALLISTIC SAM-

PLE SHIPMENT OR FOR TROOP USE AT POST, CAMP OR STATION. SEE GEN-

ERAL NOTE "R" ON PAGE 3, AND GENERAL NOTE "DD" ON PAGE 4 FOR ADDI-

TIONAL GUIDANCE.

5. LESS-THAN-FULL BOXES OF AN AMMUNITION ITEM (LIGHT BOXES) ARE LIM-

ITED TO ONLY ONE LIGHT BOX PER ITEM LOT. A UNIT LOAD WILL NOT CON-

TAIN MORE THAN ONE LIGHT BOX PER ITEM LOT ON A PALLET. ADDITIONAL

REQUIREMENTS ARE SPECIFIED IN THE "PROVISIONS FOR LESS-THAN-FULL-

LAYER UNIT LOADS" ON PAGE 7.

6. A UNIT LOAD, SUCH AS THE LAST UNIT LOAD FOR AN AMMUNITION LOT, CAN

BE ASSEMBLED WITH LESS LAYERS THAN SPECIFIED FOR THE BASIC UNIT

LOAD. THE UNIT LOAD CAN ALSO BE ASSEMBLED WITH A PARTIAL TOP LAY-

ER PROVIDING IT IS TO BE SHIPPED WITHIN CONUS TO A DEPOT, DEPOT AC-

TIVITY, POST, CAMP, OR STATION. FOR OCONUS OR FOREIGN MILITARY

SALES (FMS) SHIPMENTS, HOWEVER, THE UNIT LOAD MUST NOT BE ASSEM-

BLED WITH A PARTIAL LAYER. EMPTY BOXES OR FILLER ASSEMBLIES WILL

BE USED TO ACHIEVE FULL-LAYER CONFIGURATION. FOR ADDITIONAL GUID-

ANCE, SEE GENERAL NOTE "F" AND THE "LESS-THAN-FULL LAYER UNIT

LOADS" PROCEDURES ON PAGE 7.

E. ANY REQUEST FOR DEVIATION FROM THE STANDARDS DESCRIBED IN GENERAL

NOTE “D” OR FROM THE PROCEDURES DELINEATED IN AN APPENDIX MUST BE

DIRECTED TO THE COMMANDER, COMBAT CAPABILITIES DEVELOPMENT COM-

MAND ARMAMENTS CENTER, ATTN: CFDD-ACE-LTP, ROCK ISLAND, IL 61299-7300,

FOR SPECIFIC APPROVAL. FOR EXAMPLE, SPECIFIC APPROVAL MUST BE OB-

TAINED FOR UNITIZATION OF AN ITEM WHEN PACKED IN BOXES WHICH ARE DIF-

FERENT IN SIZE THAN THOSE SHOWN IN THE APPENDIX FOR THAT ITEM, EVEN

THOUGH THE UNIT LOAD MAY COMPLY WITH THE STANDARDS DESCRIBED IN

GENERAL NOTE “D”.

F. EXCEPT AS OTHERWISE STATED WITHIN GENERAL NOTE "D.6" ABOVE, UNIT

LOADS MUST ONLY BE MADE UP WITH FULL LAYERS. FOR REDUCED QUANTI-

TIES, HOWEVER, ONE OR MORE FULL LAYERS MAY BE OMITTED, AND/OR A FULL

LAYER MAY CONSIST OF BOXED ITEMS AND A FILLER ASSEMBLY OR AN EMPTY

BOX(ES). SEE THE PROVISIONS FOR "LESS-THAN-FULL-LAYER UNIT LOADS" ON

PAGE 7. ONLY ONE UNIT LOAD HAVING A REDUCED QUANTITY OF ITEMS

SHOULD BE PERMITTED PER LOT OF THAT ITEM. EACH LAYER OF BOXES WILL

BE POSITIONED SO AS TO BE CENTERED LENGTHWISE AND WIDTHWISE ON THE

DECK OF THE PALLET. CARE SHALL BE TAKEN TO INSURE THAT THE BOXES ARE

EVENLY ALIGNED HORIZONTALLY AND VERTICALLY SO THAT THE SIDES AND

ENDS OF THE UNIT LOAD DO NOT EXCEED A 1/2" TOLERANCE, RELATIVE TO THE

PALLET DECK. SEE THE “ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS”

DETAILS ON PAGE 8. ALSO, SEE GENERAL NOTE "W" ON PAGE 3 AND THE TYPI-

CAL FILLER ASSEMBLIES ON PAGE 9.

G. GENERALLY, WHEN UNITIZING BOXES WITH TOP CLEATS, BOXES WILL BE POSI-

TIONED ON THE UNIT LOAD WITH CLEATS UPWARD. IF BOXES ARE OF THE

HINGED-TOP TYPE, THE OUTSIDE BOXES IN THE TOP LAYER WILL BE POSI-

TIONED SO THAT THE HINGES WILL BE INWARD. CAUTION: ROCKETS AND

ROCKET MOTORS IN A PROPULSIVE STATE WILL BE POSITIONED IN THE UNIT

LOAD WITH ALL NOSE ENDS IN ONE DIRECTION. UNIT LOAD STRAPS, IN THESE

INSTANCES, MAY PASS OVER HINGES OF BOXES. ALSO, SEE GENERAL NOTE

"BB" ON PAGE 3.

H. A PLUS-OR-MINUS 1/4" IS ALLOWED ON OVERALL DIMENSIONS OF A FILLER AS-

SEMBLY, SPACER ASSEMBLY OR ANY OTHER DUNNAGE ASSEMBLY. HOWEVER,

SIMILAR PIECES IN AN ASSEMBLY MUST BE WITHIN 1/8" OF THE SAME DIMEN-

SION.

J. DIMENSIONAL LUMBER SPECIFIED THROUGHOUT THIS PROCEDURAL DRAWING

IS OF NOMINAL SIZE UNLESS OTHERWISE SPECIFIED. FOR EXAMPLE, 1" X 4" MA-

TERIAL IS ACTUALLY 3/4" THICK BY 3-1/2" WIDE AND 2" X 4" MATERIAL IS ACTUAL-

LY 1-1/2" THICK BY 3-1/2" WIDE.

K. IN ORDER TO OBTAIN COMPACT (SOUND) UNITS, ALL STRAPS SHALL BE LOCAT-

ED IN PROPER ALIGNMENT AND TENSIONED UNTIL THEY CUT INTO THE EDGE OF

THE BOXES AND/OR THE PALLET DECK. AFTER TENSIONING, EACH STRAP WILL

BE SECURED USING ONE SEAL AND TWO PAIR OF NOTCHES PER SEAL. SEE

"ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS" DETAILS ON PAGE 8.

SEALS MAY BE LOCATED ON A SIDE OR ON THE TOP OF THE UNIT, AS REQUIRED

BY OPERATIONAL NECESSITY. ALSO, SEE GENERAL NOTE "HH" ON PAGE 4 FOR

ACCEPTABLE SEALLESS OR CLIPLESS TOOL INFORMATION.

L. WHEN APPLYING ANY STRAP, CARE MUST BE EXERCISED TO ASSURE THAT THE

END OF THE STRAP ON THE UNDERSIDE OF THE JOINT EXTENDS AT LEAST 6"

BEYOND THE SEAL. THIS EXTRA MINIMUM LENGTH OF THE STRAP IS REQUIRED

TO PERMIT SUBSEQUENT TIGHTENING OF LOOSENED STRAPPING. RETENSION-

ING CAN BE ACCOMPLISHED WITHOUT REPLACING STRAPPING OR SPLICING

STRAPPING THROUGH THE USE OF A MANUAL OR PNEUMATIC FEEDWHEEL

TYPE TENSIONING TOOL AND THE APPLICATION OF ONE ADDITIONAL SEAL. SEE

"STRAP RETENSIONING TAB" VIEW ON PAGE 5.

(CONTINUED ON PAGE 3)

PROJECT FSA 146-75DRAWING 19-48-4116

(GENERAL NOTES CONTINUED FROM PAGE 2)

M. DETERMINATION OF LENGTH OF STRAPPING. THE FOLLOWING DEFINITIONS

APPLY:

L = LENGTH OF STRAP REQUIRED IN INCHES

A = LENGTH OF UNIT IN INCHES

W = WIDTH OF UNIT IN INCHES

H = HEIGHT OF UNIT, INCLUDING PALLET, IN INCHES

1. THE LENGTH OF A LOAD STRAP REQUIRED FOR A SPECIFIC UNIT, WHERE

THE STRAP PASSES THROUGH THE STRAP SLOT OR ABOVE THE PALLET

DECK, WILL BE DETERMINED BY USING THE FOLLOWING FORMULA:

L = 2W + 2H + 2".

2. THE LENGTH OF A HORIZONTAL STRAP REQUIRED FOR A SPECIFIC UNIT,

WHERE THE STRAP ENCIRCLES THE UNIT LOAD, WILL BE DETERMINED BY

USING THE FOLLOWING FORMULA: L = 2A + 2W + 12".

3. THE LENGTH OF A TIEDOWN STRAP REQUIRED FOR A SPECIFIC UNIT,

WHERE THE STRAP PASSES UNDER THE PALLET DECK, WILL BE DETER-

MINED BY USING THE FOLLOWING FORMULA: L = 2A + 2H + 2".

N. PALLET UNIT LOADS SHALL BE INSPECTED FOR TORN, DETERIORATED OR

LOOSENED STRAPPING PRIOR TO SHIPPING.

1. TORN OR BROKEN STRAPS SHOULD BE REPLACED BY CONTRACTORS,

BUT MAY BE REPAIRED AT THE DEPOT/FIELD LEVEL BY SPLICING IN A

MANNER SIMILAR TO THAT DESCRIBED IN “N.4(B)” BELOW.

2. DETERIORATION DUE TO A MINOR AMOUNT OF RUST WILL NOT NECES-

SARILY BE CAUSE FOR REPLACING A STRAP. HOWEVER, AN EXTENSIVELY

RUSTED/SCALED/PITTED STRAP IS CAUSE FOR REPLACING THE STRAP.

3. A DAMAGED OR DEFECTIVE SEAL IS SUFFICIENT CAUSE FOR REPLACE-

MENT OF THE SEAL.

4. LOOSE STRAPS SHOULD BE CHECKED FOR DEGREE OF LOOSENESS BY

POSITIONING THE HOOK OF A SCALE (COMMONLY KNOWN AS A FISH

SCALE) BEHIND THE STRAPS NEAR THE MIDPOINT AT THE TOP OR SIDE OF

THE UNIT LOAD. PULL THE SCALE UNTIL A READING OF 20 POUNDS IS OB-

TAINED. THE DISTANCE BETWEEN THE BOX AND THE STRAP MUST NOT

EXCEED 1-1/2". IF MEASUREMENT EXCEEDS 1-1/2", THE STRAP MUST BE

TIGHTENED OR REPLACED. SEE PAGE 5 FOR GUIDANCE. TIGHTENING

CAN BE ACCOMPLISHED BY EITHER OF TWO METHODS.

(A) A STRAP TENSIONING TOOL CAN BE USED IF THE STRAP HAS AT

LEAST A 6" LONG TAB AT THE SEAL. SEE GENERAL NOTE "L" ON PAGE

2.

(B) AN 18" OR LONGER STRAP CAN BE USED AS A SPLICE PIECE. CUT THE

LOOSE STRAP ON BOTH SIDES OF THE ORIGINAL SEAL AND DISCARD

THE CUT OUT SECTION. OVERLAP ONE END OF THE STRAP SPLICE

PIECE TO ONE END OF THE ORIGINAL STRAPPING SO AS TO PRO-

TRUDE SLIGHTLY BEYOND THE END OF THE SEAL TO BE USED. POSI-

TION AND SECURE SEAL TO OVERLAPPED SECTION WITH TWO PAIR

OF NOTCHES. USING A STRAPPING TOOL, TENSION AND SEAL THE

LENGTHENED STRAP. THE STRAP SPLICE PIECE MAY BE CUT FROM

NEW STRAP OR USED STRAP, PROVIDED IT IS AT LEAST OF AS GOOD

A QUALITY AS THE STRAP TO WHICH IT IS BEING SECURED. NOTE:

ONLY ONE SPLICE PER STRAP IS ALLOWED ON UNIT LOADS OF AM-

MUNITION.

5. CAUTION: WHEN A STRAP IS REPLACED/SPLICED OR RETENSIONED, AND

THE OTHER STRAPS ON A UNIT LOAD ARE NOT, CARE MUST BE EXER-

CISED TO INSURE THAT THE TENSION ON THE AFFECTED STRAP IS NEAR-

LY THE SAME AS THAT OF THE OTHER STRAPS.

O. AMMUNITION UNITIZED PRIOR TO DISTRIBUTION OF THIS DRAWING OR OF AN

APPENDIX THERETO, NEED NOT BE REUNITIZED SOLELY TO CONFORM TO

THE STANDARDS SPECIFIED HEREIN OR TO THE METHOD SHOWN IN AN AUG-

MENTING APPENDIX. HOWEVER, BOX AND STRAP ALIGNMENT MUST CON-

FORM TO THE TOLERANCE STANDARDS SPECIFIED ON PAGE 8 OF THIS

DRAWING BEFORE A UNIT IS ACCEPTABLE FOR SHIPMENT. ALSO, THE CON-

DITION OF THE UNITIZING STRAPPING ON A UNIT LOAD MUST COMPLY WITH

THE CRITERIA OF GENERAL NOTE "N" ABOVE.

P. ROOFING NAILS IN ACCORDANCE WITH ASTM F1667 NL RF R-02Z MAY BE

USED AS AN ALTERNATE TO STAPLES FOR SECURING STEEL STRAPS TO

BOARDS. NAILS MUST BE APPLIED NEXT TO THE STRAPPING SUCH THAT THE

NAIL HEADS OVERLAP THE STRAPPING. APPLY TWO NAILS IN PAIRS (TO RE-

PLACE ONE STAPLE) ON EITHER SIDE OF THE STRAP, WITH THE SECOND NAIL

APPLIED APPROXIMATELY 180 DEGREES FROM THE FIRST NAIL.

Q. UNIT LOAD MARKING WILL BE ACCOMPLISHED IN ACCORDANCE WITH DAC

DRAWING ACV00561, UNIT LOAD MARKING FOR SHIPMENT AND STORAGE,

AMMUNITION AND EXPLOSIVES.

R. IF THE REQUISITION QUANTITY IN SUPPORT OF AN AMMUNITION SHIPMENT IS

LESS THAN A FULL LAYER QUANTITY OF BOXES FOR A UNIT LOAD, THE BOXES

NEED NOT BE PALLETIZED FOR SHIPMENT. THE BOXES MAY BE PALLETIZED,

HOWEVER, FOR ENHANCED HANDLING, CLASSIFIED/SENSITIVE ITEM CONSID-

ERATIONS, ETC., BUT DO NOT REQUIRE FILLER ASSEMBLIES TO COMPLETELY

FILL OUT THE PALLET. NOTE THAT THE METHOD FOR BRACING AND STAYING

ON THE LOOSE OR PALLETIZED BOXES MUST COMPLY WITH THE METHODS

SPECIFIED WITHIN THE APPLICABLE 19-48 SERIES OUTLOADING PROCEDURAL

DRAWING.

(CONTINUED AT RIGHT)

(GENERAL NOTES CONTINUED)

S. OUTLOADING AND STORAGE OF PALLET UNITS SHALL BE ACCOMPLISHED IN

ACCORDANCE WITH APPLICABLE PROCEDURAL DRAWINGS AS IDENTIFIED IN

THE APPENDICES FOR SPECIFIC UNITS. THESE DRAWINGS ARE AVAILABLE

AT HTTPS://WWW.DAU.EDU/COP/AMMO/PAGES/DEFAULT.ASPX. CONTACT THE

DEFENSE AMMUNITION CENTER AT THE ABOVE WEB ADDRESS IF SPECIFIC

STORAGE AND OUTLOADING DRAWINGS ARE NOT IDENTIFIED WITHIN A PAR-

TICULAR APPENDIX.

T. CONVERSION TO METRIC EQUIVALENTS: DIMENSIONS WITHIN THIS DOCU-

MENT ARE EXPRESSED IN INCHES, AND WEIGHTS ARE EXPRESSED IN

POUNDS. WHEN NECESSARY, THE METRIC EQUIVALENTS MAY BE COMPUTED

ON THE BASIS OF ONE INCH EQUALS 25.4MM AND ONE POUND EQUALS 0.454

KG.

U. WHEN ASSEMBLING A COMPLETE PALLET UNIT, CARE SHALL BE TAKEN TO

INSURE THAT THE AMMUNITION ITEM PACKAGES AND DUNNAGE ASSEMBLIES,

AS APPLICABLE, ARE EVENLY ALIGNED SO THAT THE SIDES AND ENDS OF

THE PALLET UNIT DO NOT EXCEED A 1/2" TOLERANCE, RELATIVE TO THE PAL-

LET. SEE THE "ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS" DETAILS

ON PAGE 8.

V. A SPACER ASSEMBLY WILL BE DESIGNED SO THAT BOXES ON EACH SIDE OF

A VOID WITHIN A UNIT LOAD WILL BE BRACED AS STRONGLY AS IF THE VOID

WAS OCCUPIED BY THE BOXES THAT MAKE UP THE UNIT LOAD. ALSO, A

SPACER ASSEMBLY WILL BE DESIGNED IN A MANNER THAT WILL PREVENT

DAMAGE TO ADJACENT BOXES. GENERALLY, VERTICAL PIECES OF AN AS-

SEMBLY WILL BE INSTALLED AT THE OUTER EDGES OF A UNIT LOAD AND AT

LOCATIONS TO BE CENTERED ON ALL VERTICAL JOINTS BETWEEN ADJACENT

STACKS. ADDITIONALLY, AS GENERAL GUIDANCE, HORIZONTAL PIECES OF

AN ASSEMBLY WILL BE INSTALLED AT THE TOP AND BOTTOM OF THE TOP

AND BOTTOM LAYERS, RESPECTIVELY, AND AT LOCATIONS TO BE CENTERED

ON ALL HORIZONTAL JOINTS BETWEEN LAYERS. WHEN A SPACER ASSEMBLY

IS REQUIRED TO BE USED WITHIN A UNIT LOAD, THE CONSTRUCTION SPECI-

FICATIONS AND DETAIL WILL BE PROVIDED WITHIN THE APPLICABLE APPEN-

DIX FOR THE ITEM TO BE UNITIZED.

W. FILLER ASSEMBLIES ARE DESIGNED SO AS TO PROVIDE LATERAL AND LONGI-

TUDINAL BRACING WITHIN THE UNIT LOAD EQUIVALENT TO OR GREATER

THAN THE STRENGTH OF THE BOX(ES) BEING OMITTED FROM A LAYER.

WHEN A FILLER ASSEMBLY IS REQUIRED TO BE USED WITHIN A UNIT LOAD,

THE CONSTRUCTION SPECIFICATIONS AND DETAILS WILL BE PROVIDED IN

THE APPLICABLE APPENDIX FOR THE ITEM TO BE UNITIZED. SEE THE TYPI-

CAL FILLER ASSEMBLIES ON PAGE 9.

X. WHEN UNITIZING ITEMS PACKED IN WIREBOUND BOXES, AN END CLEAT OF A

BOX MAY BREAK OR BECOME DEFORMED TO AN UNACCEPTABLE DEGREE

DUE TO STRAP TENSIONING. IN THE INITIAL ASSEMBLY OF A UNIT LOAD AT A

FACILITY, SUCH AS A MANUFACTURING PLANT, A BOX WITH A BROKEN OR

BADLY DEFORMED END CLEAT WILL BE REPLACED AND THE UNIT RE-

STRAPPED AS REQUIRED. IF IT IS IMPOSSIBLE TO INSTALL A UNITIZING

STRAP NEAR A BOX END CLEAT, A 1" X 3" FILLER BLOCK MAY BE PLACED UN-

DER A STRAP TO PROVIDE ADDITIONAL STRENGTH FOR THE BOX. THE FILLER

BLOCK LENGTH WILL BE CUT-TO-FIT BETWEEN OPPOSITE CLEATS, AND IT

WILL BE SECURED TO THE STRAP WITH TWO STAPLES. DUNNAGE GRADE OR

A BETTER GRADE LUMBER CAN BE USED FOR FILLER BLOCKS. IF DURING

HANDLING, OUTLOADING OR STORAGE OPERATIONS A UNIT LOAD IS FOUND

WITH A BOX WHICH HAS A BROKEN OR DEFORMED END CLEAT AND A RE-

PLACEMENT BOX IS NOT AVAILABLE OR IT IS DEEMED IMPRACTICAL TO RE-

PLACE THE BOX, AN ACCEPTABLE "FIX" CAN BE ACCOMPLISHED BY USING A

FILLER BLOCK AS SPECIFIED ABOVE. INSERT A BLOCK BETWEEN CLEATS AT

THE BREAK OR DEFORMATION. RETENSION EXISTING STRAPPING IF POSSI-

BLE OR INSTALL NEW STRAPPING AS REQUIRED. SEE THE "SPECIAL REIN-

FORCEMENT FOR WIREBOUND BOXES" DETAIL ON PAGE 5.

Y. WHEN UNITIZING ITEMS PACKED IN WIREBOUND BOXES, ALLOWABLE OVER-

HANG FOR THE BOXES IS AS FOLLOWS: WIREBOUND BOXES CONTAINING

RECTANGULAR METAL CONTAINERS AS INNER PACKS CAN OVERHANG THE

PALLET AS SPECIFIED IN GENERAL NOTE "D" ON PAGE 2. WIREBOUND BOXES

WITH INNER PACKS OTHER THAN RECTANGULAR METAL CONTAINERS WILL

NOT OVERHANG THE PALLET IN EXCESS OF ONE-HALF THE THICKNESS OF

THE BATTENS OR END CLEATS OF THE BOX, UNLESS SUPPORTED BY DUN-

NAGE MATERIAL FASTENED TO THE PALLET DECK, OR AS SPECIFIED WITH A

SEPARATELY ISSUED APPENDIX.

Z. DIMENSIONS GIVEN FOR DUNNAGE ASSEMBLIES WILL BE FIELD CHECKED

PRIOR TO THEIR ASSEMBLY. THIS GUIDANCE MUST BE APPLIED PRIOR TO

BEGINNING A PALLETIZING OPERATION. ALSO, DUE TO VARIATIONS OF

PACKAGE DIMENSIONS, ADJUSTMENTS MAY BE REQUIRED AS TO THE LOCA-

TION OF CERTAIN PIECES ON DUNNAGE ASSEMBLIES. THESE ASSEMBLIES

SHALL NOT PROTRUDE PAST THE TOP AND/OR SIDES OF THE BOXES.

AA. ALL WOODEN DUNNAGE USED IN UNIT LOADS SHALL BE TREATED WITH EI-

THER TYPE I OR TYPE III WOOD PRESERVATIVE, IN ACCORDANCE WITH

ARDEC DRAWING 13064136. IF THE DUNNAGE CONSISTS OF MORE THAN ONE

COMPONENT, IT MUST BE ASSEMBLED PRIOR TO TREATMENT. PRESERVATIVE

MARKING SHALL BE APPLIED TO AT LEAST ONE LOCATION ON THE ASSEMBLY

OR COMPONENT IN ACCORDANCE WITH PARAGRAPH 3.3.6 OF ARDEC DRAW-

ING 13064136.

BB. WHEN UNITIZING BOXES WITH TOP CLEATS AND THE BOXES ARE POSITIONED

ON THEIR SIDES, THE BOXES LOCATED IN THE OUTER STACKS MUST HAVE

THE TOP CLEATS TURNED INWARD, EXCEPT AS OTHERWISE SPECIFIED IN

DAC DRAWING ACV00561.

(CONTINUED ON PAGE 4)

(GENERAL NOTES CONTINUED FROM PAGE 3)

CC. WHERE 3/4" UNITIZING STEEL STRAPPING IS SPECIFIED FOR USE BY AN APPEN-

DIX THAT AUGMENTS THIS DRAWING, 1-1/4" STRAPPING MAY BE SUBSTITUTED

FOR THE 3/4" STRAPPING, PROVIDED THAT TWO BASIC REQUIREMENTS ARE

SATISFIED. ALL OF THE SPECIFICATION CRITERIA SET FORTH UNDER THE "MA-

TERIAL SPECIFICATIONS" FOR THE 3/4" STRAPPING AND STRAP SEALS WILL BE

USED FOR THE 1-1/4" STRAPPING AND SEALS, EXCEPT FOR THE SIZE CRITERION.

APPROVAL TO USE THE ALTERNATIVE MATERIALS MUST BE ACQUIRED IN AC-

CORDANCE WITH THE GUIDANCE SET FORTH BY GENERAL NOTE "E" ON PAGE 2

PRIOR TO USING THE 1-1/4" STRAPPING AND SEALS. NOTICE: REQUESTS TO

USE SUBSTITUTE MATERIALS MUST BE HANDLED ON A CASE BY CASE BASIS. AN

APPROVAL TO USE 1-1/4" MATERIALS IS NOT A BLANKET APPROVAL TO ALL AP-

PENDICES.

DD. GENERAL NOTE "D.4" ON PAGE 2 SPECIFIES THAT NO MORE THAN TWO LOTS OF

AMMUNITION WILL BE CONTAINED ON A PALLET UNLESS IN SUPPORT OF BALLIS-

TIC SAMPLE SHIPMENT OR TROOP USE AT POST, CAMP, OR STATION. THIS IS

INTENDED TO BE APPLIED TO PALLETIZING OPERATIONS BEING PERFORMED AT

A LOAD, ASSEMBLE AND PACK PLANT OR TO MAJOR MAINTENANCE OPERATIONS

BEING PERFORMED AT AN AMMUNITION DEPOT WHEN THE QUANTITY OF BOXES

COMPRISING A LOT IS GREAT ENOUGH TO CONSTRUCT MORE THAN ONE PALLET

UNIT. NOTICE: MULTIPLE (MORE THAN TWO) LOTS ARE PERMITTED TO BE PAL-

LETIZED TOGETHER AS A UNIT LOAD WHEN A SINGLE LOT QUANTITY IS INSUFFI-

CIENT TO COMPLETE ONE FULL-SIZE OR REDUCED-LAYER (TO SATISFY A SMALL-

QUANTITY SHIPMENT) UNIT LOAD. ADDITIONALLY, MULTIPLE LOTS ON A PALLET

MAY CONSIST OF ONE OR MORE NSNS, PROVIDED ALL ITEMS ARE COMPATIBLE

AND THEY ARE BEING SHIPPED TO A SINGLE CONUS POST, CAMP OR STATION.

PALLETS CONTAINING MULTIPLE NSNS WILL NOT BE SHIPPED TO CONUS OR

OCONUS DEPOTS. MULTIPLE NSN PALLET UNITS WILL HAVE STEEL STRAPPING

APPLIED SIMILAR TO PALLET STRAPPING GUIDANCE CONTAINED IN THE APPLI-

CABLE ITEM APPENDIX. ALL ITEM BOXES ON THE PALLET MUST BE RESTRAINED

IN SUCH A MANNER TO PROVIDE A SAFE, SECURE, AND COMPACT PALLET UNIT

FOR SHIPMENT. MULTIPLE LOT/NSN UNIT LOADS WILL BE MARKED IN ACCORD-

ANCE WITH DAC DRAWING ACV00561.

EE. TWO METHODS ARE APPROVED FOR DETERMINING THE AVERAGE WEIGHT THAT

IS TO BE SHOWN ON PALLETIZED UNITS OF AMMUNITION THAT ARE BEING PRO-

DUCED AT LOAD, ASSEMBLE AND PACK PLANTS.

1. PREFERRED METHOD: RANDOMLY SELECT FIVE UNIT LOADS FROM THE

CURRENT MONTH'S PRODUCTION. WEIGH EACH UNIT LOAD. THE CALCU-

LATED AVERAGE WEIGHT OF THE FIVE UNIT LOADS (TOTAL WEIGHT OF THE

FIVE UNIT LOADS DIVIDED BY FIVE) WILL BE USED AS THE UNIT LOAD WEIGHT

FOR WHICHEVER IS LESS, EITHER A 60-DAY PERIOD OR UNTIL A DIMENSION-

AL OR CONFIGURATION CHANGE IS MADE TO THE UNIT LOAD.

2. ALTERNATIVE METHOD: RANDOMLY SELECT AND WEIGH FIVE GROUPS OF

UNIT LOAD COMPONENTS (PALLET, STRAPPING, SEALS, SPACER ASSEM-

BLIES, BATTENS, ETC.) FROM THE CURRENT MONTH'S PRODUCTION AND

ADDING TO IT THE WEIGHT OF THE LOADED BOXES TO BE PLACED ON THE

PALLET. THE WEIGHT OF THE LOADED BOXES WILL BE DETERMINED BY US-

ING THE FOLLOWING PROCEDURES:

(A) WEIGH FIVE LOADED BOXES INDIVIDUALLY AND RECORD THE TOTAL

WEIGHT.

(B) WEIGH THREE INDIVIDUAL GROUPS OF FIVE LOADED BOXES EACH AND

RECORD EACH GROUP WEIGHT.

(C) WEIGH THREE INDIVIDUAL GROUPS OF TEN LOADED BOXES EACH AND

RECORD EACH GROUP WEIGHT.

(D) TOTAL ALL RECORDED WEIGHTS AND DIVIDE BY 50. THE RESULT IS THE

APPROVED LOADED BOX GROSS WEIGHT.

THE APPROVED LOADED BOX GROSS WEIGHT WILL THEN BE MULTIPLIED BY THE

QUANTITY OF BOXES TO BE PLACED ON THE PALLET AND ADDED TO EACH

GROUP OF UNIT LOAD COMPONENTS. THE CALCULATED AVERAGE WEIGHT OF

THE FIVE UNIT LOAD GROUPS (TOTAL WEIGHT OF THE FIVE UNIT LOAD GROUPS

DIVIDED BY FIVE) WILL BE USED AS THE UNIT LOAD WEIGHT FOR WHICHEVER IS

LESS, EITHER A 60-DAY PERIOD OR UNTIL A DIMENSIONAL OR CONFIGURATION

CHANGE IS MADE TO THE UNIT LOAD.

FF. WHEN UN PERFORMANCE ORIENTED PACKAGING (POP) MARKING IS REQUIRED

ON BOXES, THIS MARKING WILL SHOW IN AT LEAST ONE PLACE ON THE UNIT-

IZED LOADS.

GG. COOLER NAILS MAY BE SUBSTITUTED FOR THE COMMON NAILS AS SPECIFIED

WITHIN EACH APPENDIX BY APPLYING THE FOLLOWING GUIDANCE. THE NUM-

BER OF COOLER NAILS TO BE USED WILL BE THE NUMBER OF COMMON NAILS

MULTIPLIED BY 1.2 AND ROUNDED UP TO THE NEXT WHOLE NUMBER. THE SIZE

OF THE COOLER NAILS TO BE USED WILL BE THE SAME AS SPECIFIED FOR THE

COMMON NAILS (4d, 6d, 10d, ETC.) BUT WILL CONFORM TO THE SIZE AND

WEIGHT TOLERANCES SPECIFIED WITHIN ASTM F1667 FOR COOLER NAILS.

HH. REFER TO DAC DRAWING ACV00617 FOR APPROVED SOURCES FOR SEALLESS

(CLIPLESS) SEALING TOOL. THESE APPROVED SEALING TOOLS CAN BE USED IN

PLACE OF SEALS CURRENTLY SPECIFIED IN THE "MATERIAL SPECIFICATIONS"

ON PAGE 2.

JJ. ALL NON-MANUFACTURED WOOD USED IN THE UNIT LOAD WILL BE HEAT TREAT-

ED AND MARKED TO SHOW CONFORMANCE TO THE INTERNATIONAL PLANT

PROTECTION CONVENTION STANDARD (IPPC), ISPM-15. SEE DAC DRAWING

ACV00831 FOR ISPM-15 CERTIFICATION MARKING AND PLACEMENT DETAILS.

FILLER BLOCK, 1" X 3" BY CUT-TO- FIT

BETWEEN OPPOSITE END-CLEATS OF BOX.

POSITION UNDER STRAP.

INDICATES A

HORIZONTAL STRAP

INDICATES

WIREBOUND BOX

INDICATES BROKEN

END-CLEAT

STAPLE STRAP TO FILLER

BLOCK W/2 STAPLES.

INDICATES A TIEDOWN OR LOAD

STRAP THAT CANNOT BE INSTALLED

AT THE PREFERRED LOCATION.

INDICATES A PREFERRED

LOCATION FOR ALL UNIT-

IZING STRAPS (NEAR A

CLEAT WHICH IS PARALLEL

TO THE STRAP).

FILLER BLOCK FOR

HORIZONTAL STRAP

SPECIAL REINFORCEMENT FOR WIREBOUND BOXES

SEE GENERAL NOTE “X” ON PAGE 3.

INDICATES BROKEN

END-CLEAT

OTHER STRAP END

ON TOP SIDE

STEEL STRAPPING

STRAP RETENSIONING

TAB. SIX INCH MINIMUM

LENGTH TAB ON END

OF UNDERNEATH STRAP.

STRAP SEAL

UNITIZATION NOTES

○1 POSITION BOXES SO THEY ARE CENTERED LENGTHWISE AND WIDTHWISE ON

THE PALLET DECK. IF BOXES ARE OF THE HINGED-TOP TYPE, THE OUTSIDE

BOXES IN THE TOP LAYER WILL BE POSITIONED SO THAT THE HINGES WILL BE

INWARD. SEE GENERAL NOTE "G" ON PAGE 2.

○2 LOAD STRAP, 3/4" X .035" OR .031" OR .029” BY LENGTH TO SUIT STEEL STRAP-

PING (AS REQD). MAY BE INSTALLED THROUGH THE STRAP SLOT OF A PALLET

OR PRE-POSITIONED ON THE PALLET DECK PRIOR TO PLACING BOXES ON THE

PALLET. SEE GENERAL NOTES "K" AND "L" ON PAGE 2, AND "M" ON PAGE 3.

STRAPS SHALL NOT BE PLACED UNDER THE STRINGER BOARDS.

○3 HORIZONTAL STRAP, 3/4" X .035" OR .031" OR .029” BY LENGTH TO SUIT STEEL

STRAPPING (AS REQD). INSTALL STRAP TO ENCIRCLE A LAYER OF BOXES ON

THE PALLET AS SHOWN. SEE GENERAL NOTES "K" AND "L" ON PAGE 2, AND "M"

ON PAGE 3.

○4 TIEDOWN STRAP, 3/4" X .035" OR .031" OR .029” BY LENGTH TO SUIT STEEL

STRAPPING (AS REQD). INSTALL EACH STRAP TO PASS UNDER THE DECK

BOARDS OR DECK/STRINGER BOARDS OF THE PALLET AS SHOWN. SEE GEN-

ERAL NOTES "K" AND "L" ON PAGE 2, AND "M" ON PAGE 3.

○5 SEAL FOR 3/4" STRAPPING (AS REQD, 1 PER STRAP). CRIMP EACH SEAL WITH

TWO PAIR OF NOTCHES. SEE GENERAL NOTE "K" ON PAGE 2.

STRAP RETENSIONING TAB

SEE GENERAL NOTE “L” ON PAGE 2.

TYPICAL PALLET UNIT

UNIT WIDTH

UNIT LENGTH

35 1/2"

4-WAY ENTRY

PALLET

TYPICAL PALLET UNIT WITH ONE SPACER ASSEMBLY

THIS VIEW DEPICTS THE APPLICATION OF A TYPICAL SPACER ASSEMBLY, POSITIONED LENGTHWISE IN THE UNIT LOAD, TO ENLARGE THE UNIT WIDTH TO SLIGHTLY OVERHANG OR TO MATCH THE WIDTH DIMENSION OF THE PALLET DECK.

SIMILARLY, TO ENLARGE THE UNIT LENGTH, A SPACER ASSEMBLY WOULD BE POSITIONED WIDTHWISE IN THE LOAD. SEE

GENERAL NOTES "D.3" ON PAGE 2 AND "V" ON PAGE 3.

INDICATES CENTER STACKS WITHIN THE

UNIT LENGTH FOR POSITIONING ONE OR

MORE FILLER ASSEMBLIES WHEN REQUIRED. INDICATES A TYPICAL

SPACER ASSEMBLY

INDICATES HORIZONTAL STRAP

INDICATES TIEDOWN STRAP

4-WAY ENTRY PALLET

UNIT HEIGHT

UNIT WIDTH

UNIT LENGTH

TYPICAL PALLET UNIT WITH THREE SPACER ASSEMBLIES

THIS VIEW DEPICTS THE APPLICATION OF THREE TYPICAL SPACER ASSEMBLIES TO ENLARGE BOTH THE WIDTH AND THE LENGTH OF THE UNIT LOAD TO PROVIDE A SLIGHT OVERHANG ON THE PALLET OR TO MATCH THE WIDTH AND/OR LENGTH DIMENSIONS OF THE PALLET DECK. SEE GENERAL NOTES "D.3" ON PAGE 2 AND "V" ON PAGE 3.

INDICATES TYPICAL

SPACER ASSEMBLIES

C S C S CO OS O GO O O SS SQC S C S CG O OS O GO O O SS SQ

INDICATES TIEDOWN STRAP

INDICATES HORIZONTAL STRAP

4-WAY ENTRY PALLET

UNIT HEIGHT

UNIT WIDTH

UNIT LENGTH

PROVISIONS FOR LESS-THAN-FULL-LAYER LOADS

1. THE FOLLOWING PROVISIONS SET FORTH THE SPECIFICATIONS THAT MUST BE

FOLLOWED IF A FILLER TYPE ASSEMBLY IS USED TO ACHIEVE A FULL-LAYER

PALLET UNIT.

A. FILLERS ARE DESIGNED FOR USE IN THE PLACE OF ONE OR MORE BOXES

OF A UNIT. FILLER ASSEMBLY DETAILS WILL BE DEPICTED IN THE APPENDIX

APPLICABLE TO THE SPECIFIC ITEM TO BE UNITIZED. SEE GENERAL NOTE

"W" ON PAGE 3 AND THE TYPICAL FILLER ASSEMBLY DETAILS ON PAGE 9.

B. FILLERS WILL BE POSITIONED IN THE TOP LAYER OR LAYERS OF THE CEN-

TER STACK OR STACKS WITHIN THE UNIT LENGTH OF A UNIT LOAD AS

SHOWN IN THE TWO "TYPICAL APPLICATIONS OF FILLER" VIEWS ABOVE AND

REFERENCED IN PALLET UNIT DETAILS ON PAGE 6. FILLERS CAN ALSO BE

POSITIONED IN THE TOP LAYER OR LAYERS OF THE CENTER STACK OR

STACKS WITHIN THE UNIT WIDTH OF A UNIT LOAD WHEN THE QUANTITY OF

FILLERS POSITIONED WITHIN THE UNIT LENGTH IS INSUFFICIENT TO SATIS-

FY THE OMITTED-BOX QUANTITY REQUIREMENTS.

2. EMPTY BOXES, PREFERABLY "REJECTS", CAN BE USED AS FILLERS INSTEAD OF

WOODEN DUNNAGE ASSEMBLIES INDICATED ABOVE, TO ACHIEVE A FULL-

LAYER PALLET UNIT. HOWEVER, EMPTY BOXES WILL BE USED ONLY IN THE

TOP LAYER OF A PALLET UNIT AND POSITIONED AT ANY OF THE FOUR COR-

NERS OF THE LAYER (NOT IN THE MIDDLE OF THE LAYER). NOT MORE THAN

FOUR EMPTY BOXES MAY BE USED IN A UNIT LOAD. WHEN EMPTY BOXES ARE

USED TO FILL OUT A LAYER, THE EMPTY BOXES WILL BE PAINTED AND MARKED

AS SPECIFIED IN DAC DRAWING ACV00561 AND ARDEC DRAWING 12982865.

FOR HYDRA-70 CONFIGURATION ONLY, PAINT AND MARK AS SPECIFIED IN

AMCOM DRAWING 13643712. SEE NOTE 6 BELOW.

3. IF EMPTY WOODEN BOXES ARE USED AS FILLERS, WOOD REINFORCING

BLOCKS OF 2" THICK MATERIAL BY LENGTHS REQUIRED, MAY BE POSITIONED

INSIDE THE BOXES TO PREVENT THEM FROM CRUSHING OR COLLAPSING

WHEN UNITIZING STRAPS ARE TENSIONED. TO HOLD THE BLOCKS IN PLACE,

DRIVE 6d NAILS THROUGH THE BOX AND INTO THE ENDS OF THE REINFORCING

BLOCKS. SEE THE "TYPICAL INSTALLATION OF REINFORCING BLOCKS IN AN

EMPTY BOX" DETAIL ON THIS PAGE.

4. IF EMPTY WIREBOUND BOXES ARE TO BE USED AS FILLERS, ONLY THOSE HAV-

ING EMPTY RECTANGULAR METAL CONTAINERS AS INNER PACKS CAN BE

USED. FILLER ASSEMBLIES MUST BE USED IN PLACE OF WIREBOUND BOXES

TO SATISFY LESS-THAN-FULL-LAYER LOAD REQUIREMENTS WHEN THE INNER

PACKS OF THE WIREBOUND BOXES DO NOT CONSIST OF RECTANGULAR MET-

AL CONTAINERS.

5. LESS THAN FULL BOXES OF AMMUNITION (LIGHT BOXES) WILL BE PAINTED AND

MARKED AS SPECIFIED IN ARDEC DRAWINGS 8796522 OR 12982865. LIGHT

BOXES WILL ONLY BE PLACED IN THE TOP LAYER OF A UNIT AND LOCATED AT

ANY OF THE FOUR CORNERS OF THE LAYER (NOT IN THE MIDDLE OF THE LAY-

ER). NOT MORE THAN TWO LIGHT BOXES (ONE PER LOT) WILL BE PLACED IN A

UNIT LOAD. FOR HYDRA-70 CONFIGURATION ONLY, PAINT AND MARK AS SPEC-

IFIED IN DRAWING 13643712. SEE NOTE 6 BELOW.

6. TO SATISFY THE REQUIREMENTS FOR A FULL-LAYER UNIT, IT IS PERMISSIBLE

TO USE A COMBINATION OF EMPTY AND LIGHT BOXES IN THE TOP LAYER.

HOWEVER, IF A TOTAL OF FOUR EMPTY AND LIGHT BOXES DOES NOT PROVIDE

FOR A FULL LAYER, ONE OR MORE FILLER ASSEMBLIES MUST BE USED IN THE

MIDDLE OF THE LAYER TO INSURE COMPLIANCE WITH THE LIMITATIONS SPECI-

FIED IN NOTES 2 AND/OR 5 ABOVE.

7. EACH PALLET UNIT LOAD CONTAINING EMPTY AND/OR LIGHT BOXES WILL HAVE

A WEATHER RESISTANT PLACARD OR TAG PREPARED AND APPLIED TO THE

UNIT LOAD AS STATED IN DAC DRAWING ACV00561.

(CONTINUED ON PAGE 8)

LESS-THAN-FULL-LAYER UNIT LOADS

TYPICAL INSTALLATION OF REINFORCING

BLOCKS IN AN EMPTY BOX

(UNITIZING STRAPS HAVE BEEN OMITTED FROM THE DETAIL

ABOVE FOR CLARITY PURPOSES).

USE OF EMPTY/LIGHT BOXES TO ACHIEVE A

FULL LAYER

(UNITIZING STRAPS HAVE BEEN OMITTED FROM THE DETAIL

ABOVE FOR CLARITY PURPOSES).

TYPICAL APPLICATION OF FILLER

(ONE BOX OMITTED)

TYPICAL APPLICATION OF FILLER

(THREE BOXES OMITTED)

TYPICAL FILLER ASSEMBLY

OR ASSEMBLIES FOR THREE

OMITTED BOXES.

TYPICAL FILLER ASSEMBLY

FOR ONE OMITTED BOX.

INDICATES CENTER

STACKS OF UNIT

WIDTH

INDICATES CENTER

STACK OF UNIT

LENGTH

EMPTY/LIGHT

BOXES

TYPICAL LOCATION OF

WEATHER RESISTANT

PLACARD.

VERTICAL

REINFORCING

BLOCK

HORIZONTAL

REINFORCING

BLOCK

(PROVISIONS FOR LESS-THAN-FULL-LAYER LOADS CONTINUED FROM PAGE 7)

8. EXCEPTION TO THE RULE: THIS EXCEPTION ADDRESSES THE USE OF A FILLER ASSEMBLY OR FILLER ASSEMBLIES

WITHIN A UNIT LOAD TO CONSTRUCT A COMPLETE-LAYER UNIT LOAD. THE SPECIFICATIONS DELINEATED WITHIN THIS DRAWING ARE BASED ON UNIT LOADS THAT CONTAIN SEVERAL AMMUNITION PACKS WHICH ARE ARRANGED IN MULTIPLE LAYERS AND MULTIPLE STACKS ON A PALLET BASE. FOR THESE TYPES OF UNIT LOADS A FILLER OR FILLERS ARE TO BE PLACED AS SPECIFIED ELSEWHERE HEREIN, IN THE TOP LAYER OR LAYERS OF MIDDLE STACKS (NOT IN A CORNER STACK). THERE ARE, HOWEVER, MANY PALLET UNITS THAT ONLY CONTAIN ONE LAYER OF AMMUNITION PACKS, OR PALLET UNITS WHERE THE PACKS ARE ARRANGED IN ONLY TWO OR FOUR STACKS ON A PALLET BASE. THE USE OF A FILLER OR FILLERS IN THESE TYPES OF PALLET UNITS IS PERMITTED;

HOWEVER, THE METHODS FOR FILLER APPLICATION WILL HAVE TO DEVIATE FROM THE BASIC RULES SPECIFIED ELSEWHERE WITHIN THIS DRAWING. THIS IS ALSO THE CASE WHEN ONLY ONE PALLET UNIT OF A SPECIFIC COM- MODITY IS BEING PREPARED AND THE PALLET UNIT BEING CONSTRUCTED WILL ONLY HAVE THREE OR FEWER PACKS, WHERE NORMALLY SEVERAL PACKS ARE REQUIRED TO FILL OUT A LAYER. BASICALLY, THE PERMITTED DEVIATION FROM THE BASIC RULES GOVERNING PLACEMENT OF FILLER OR FILLERS IN A UNIT LOAD CONSISTS OF PLACING A FILLER OR FILLERS IN ONE OR MORE OF THE CORNER STACKS OF A PALLET UNIT. IF AN EMPTY "ORANGE" PACK OR PACKS ARE AVAILABLE TO FILL OUT A LAYER ON A PALLET UNIT, THE EMPTY PACK OR PACKS SHOULD BE USED IN A CORNER STACK LOCATION INSTEAD OF A FILLER ASSEMBLY. ANOTHER DEVIATION FROM THE BASIC RULES AS THEY APPLY TO USE OF FILLER ASSEMBLIES IS ALSO PERMITTED. THIS DEVIATION IS ASSO- CIATED WITH SINGLE-LAYER UNIT LOADS, AND PERMITS THE USE OF FILLER ASSEMBLIES WITH TWO UNIT LOADS RATHER THAN WITHIN JUST ONE, TO ACHIEVE SOUND AND EFFECTIVE UNIT LOADS. SPECIFIC GUIDANCE RELA- TIVE TO THE USE OF THIS LATTER DEVIATION IS SET FORTH IN APPLICABLE INDIVIDUAL APPENDICES THAT AUG-

MENT THIS BASIC PROCEDURES DRAWING.

ALLOWABLE TOLERANCES FOR ASSEMBLING UNITS

UNIT LENGTH VIEW UNIT WIDTH VIEW

UNIT TOP VIEW

SPECIAL NOTES:

1. DIMENSIONS APPLICABLE TO ALLOWABLE TOLERANCES ARE EXPRESSED IN

INCHES AND IDENTIFIED BY LETTERS AS FOLLOWS.

A = UNIT LENGTH

B = PALLET LENGTH

C = UNIT WIDTH

D = PALLET WIDTH

E = LENGTHWISE OVERHANG = (A-B) / 2 WITH A PLUS OR MINUS 1/2" TOLER-

ANCE FOR EACH LAYER AND FOR EACH STACK

F = ALLOWABLE UNIT LENGTH = "A" PLUS 1/2" MAXIMUM

G = WIDTHWISE OVERHANG = (C-D) / 2 WITH A PLUS OR MINUS 1/2" TOLER-

ANCE FOR EACH LAYER AND FOR EACH STACK

H = ALLOWABLE UNIT WIDTH = "C" PLUS 1/2" MAXIMUM

J = UNIT HEIGHT

K = VERTICAL STRAP ALIGNMENT = J / 40 = MAXIMUM INCHES FROM TRUE

ALIGNMENT (E.G., IF J = 50", K = 50” / 40" = 1-1/4" MAX)

L = TRANSVERSE STRAP ALIGNMENT = C / 40 = MAXIMUM INCHES FROM TRUE

ALIGNMENT (E.G., IF C = 55", L = 55” / 40" = 1-3/8" MAX)

2. BOX ALIGNMENT TOLERANCES APPLY TO EACH LAYER AND TO EACH STACK

RELATIVE TO THE PALLET DECK. SEE GENERAL NOTE "F" ON PAGE 2 AND "U"

ON PAGE 3.

3. STRAPPING TOLERANCES APPLY TO ALL STRAPS AND TO ALL SURFACES

WHICH EACH STRAP ENCOMPASSES, I. E., TOP, BOTTOM, AND BOTH SIDES.

F

A

B E

INDICATES

STRAP

J

H

C

J

DG

C

F

D

GEINDICATES PALLET

(PHANTOM)

L

INDICATES BOX

INDICATES STRAP

K

SPECIAL NOTES:

1. TYPICAL FILLER ASSEMBLIES “A” AND “B” ARE TYPICAL OF THE ASSEMBLIES

USED TO REPLACE CLEATED WOODEN BOXES, AND TYPICAL FILLER ASSEM-

BLIES “C” AND “D” ARE TYPICAL OF THE ASSEMBLIES USED TO REPLACE

WIREBOUND BOXES. THE DECISION OF WHICH FILLER ASSEMBLY TO USE

WILL BE BASED UPON MATERIAL AVAILABILITY AND CONSTRUCTION ECONOM-

ICS.

2. FILLER ASSEMBLIES MUST BE ASSEMBLED WITHIN ALLOWABLE TOLERANCES.

SEE GENERAL NOTE "H" ON PAGE 2.

3. SEE THE APPLICABLE APPENDIX TO DETERMINE THE RECOMMENDED FILLER

ASSEMBLY FOR A PARTICULAR ITEM. SEE GENERAL NOTE "W" ON PAGE 3.

TYPICAL FILLER ASSEMBLY D

SEE SPECIAL NOTES BELOW.

TYPICAL FILLER ASSEMBLY C

TYPICAL FILLER ASSEMBLY A

TYPICAL FILLER ASSEMBLY B

INDICATES 1" X 4"

DUNNAGE LUMBER

INDICATES 2"

DUNNAGE LUMBER

INDICATES APPROPRIATELY

SIZED NAILS (AS REQD)

BOX LENGTH

BOX HEIGHT

BOX WIDTH

1"

BOX LENGTH

INDICATES 1" X 4"

DUNNAGE LUMBER

BOX WIDTH

INDICATES 2"

DUNNAGE LUMBER

INDICATES APPROPRIATELY

SIZED NAILS (AS REQD)

1"

BOX HEIGHT

BOX LENGTH BOX WIDTH

INDICATES 1" X 4"

DUNNAGE LUMBER

INDICATES 2"

DUNNAGE LUMBER INDICATES APPROPRIATELY

SIZED NAILS (AS REQD)

BOX WIDTHBOX LENGTH

BOX HEIGHT

INDICATES APPROPRIATELY

SIZED NAILS (AS REQD) INDICATES 2"

DUNNAGE LUMBER

REVISIONS

REVISION NO. 1, DATED OCTOBER 1983, CONSISTS OF:

1. ADDING NOTES TO COVER UNITIZATION OF WIREBOUND BOXES.

2. UPDATING NOTES AND PROCEDURES TO CONFORM TO CURRENT STANDARD.

REVISION NO. 2, DATED JUNE 1985, CONSISTS OF:

CHANGING GENERAL NOTE “AA” TO CONFORM TO CURRENT STANDARDS.

REVISION NO. 3, DATED DECEMBER 1986, CONSISTS OF:

ADDING PAGE 8 (FILLER ASSEMBLIES).

REVISION NO. 4, DATED FEBRUARY 1989, CONSISTS OF:

UPDATING GENERAL NOTES.

REVISION NO. 5, DATED MARCH 1996, CONSISTS OF:

UPDATING GENERAL NOTES.

REVISION NO. 6, DATED JUNE 2000, CONSISTS OF:

1. UPDATING MATERIAL SPECIFICATIONS AND RELATED GENERAL NOTES.

2. ADDING DAC WEB SITE INFORMATION.

3. ADDING THE CLIPLESS SEAL NOTE.

REVISION NO. 7, DATED SEPTEMBER 2001, CONSISTS OF:

UPDATING GENERAL NOTE “E” AND ADDING GENERAL NOTE “JJ”.

REVISION NO. 8, DATED JUNE 2003, CONSISTS OF CHANGES PER ECPS R2K3000 AND R2K3010 INCLUD-

ING:

1. UPDATING STRAPPING, WOOD AND STAPLE SPECIFICATIONS.

2. UPDATING GENERAL NOTE “JJ”.

REVISION NO. 9, DATED AUGUST 2005, CONSISTS OF:

1. UPDATING GENERAL NOTES.

2. REMOVING STRAP CUTTER NOTE (GENERAL NOTE “P”) AND REFERENCES AND REPLACING IT WITH

ROOFING NAIL NOTE.

REVISION NO. 10, DATED AUGUST 2006, CONSISTS OF:

1. UPDATING GENERAL NOTE “JJ”.

2. ADDING PLYWOOD MATERIAL SPECIFICATION.

REVISION NO. 11, DATED JULY 2008, CONSISTS OF CHANGES PER ECPS R07K3013 (1-2), R08K2045 (3), AND R08K3007 (4) INCLUDING:

1. UPDATING STEEL STRAPPING SPECIFICATION TO INCLUDE .029” THICKNESS STRAPPING.

2. DELETING REFERENCE TO TANALITH E OR TANALITH E3492 FROM GENERAL NOTE “AA”.

3. DELETING CONFIGURATION MANAGEMENT STATEMENT.

4. UPDATING STAPLE SPECIFICATION TO ALLOW STFCS-198 OR -216 STAPLE.

REVISION NO. 12, DATED DECEMBER 2011, CONSISTS OF CHANGES PER ECP R11K3001 INCLUDING:

1. UPDATING DRAWING FORMAT.

2. UPDATING OFFICE SYMBOL ON COVER PAGE AND IN GENERAL NOTE “E”.

3. CORRECTING MISSPELLING IN GENERAL NOTE “P”.

4. UPDATING GENERAL NOTE “S” TO REMOVE REFERENCE TO DRAWING INDEX, AMC 19-48-75-5.

5. CHANGING MIL-B-2427 TO MIL-DTL-2427 IN GENERAL NOTE “AA”.

6. REWORDING GENERAL NOTE “JJ” WITH NEW REFERENCE TO DAC DRAWING ACV00831.

7. UPDATING STRAP THICKNESS IN UNITIZATION NOTES 2, 3, AND 4 ON PAGE 5.

REVISION NO. 13, DATED JANUARY 2017, CONSISTS OF CHANGES PER ECP MI-R0891 (2) INCLUDING:

1. UPDATING DRAWING FORMAT.

2. CHANGING MIL-P-15011 TO MIL-DTL-15011 IN THE PALLET MATERIAL SPECIFICATIONS.

3. DELETING REFERENCE TO GENERAL NOTE “JJ” (HEAT TREATMENT) FROM PALLET SPECIFICATION.

4. UPDATING GENERAL NOTE “AA” (PRESERVATIVE TREATMENT) TO INCORPORATE NEW ARDEC

DRAWING.

REVISION NO. 14, DATED DECEMBER 2019, CONSISTS OF CHANGES PER ECP MI-P1690R2A1 NOR 79 IN-

CLUDING:

UPDATING NOTES 2 AND 5 ON PAGE 7 TO INCLUDE PAINT AND MARK INFORMATION FOR HYDRA-70.

REV.

DESIGN

ENGINEER

BASIC

ENGINEERING

DIVISON

EXPLOSIVES

SAFETY

DIRECTORATE

CLASS DIVISION DRAWING FILE

U.S. ARMY MATERIEL COMMAND DRAWING

DO NOT SCALE

PROJECT FSA 146/5C-75

NOTICE: THIS APPENDIX CANNOT STAND ALONE BUT MUST BE USED IN CONJUNCTION WITH THE BASIC UNITIZATION

PROCEDURES DRAWING 19-48-4116-20PA1002.

19 48

DISTRIBUTION STATEMENT A:

APPROVED FOR PUBLIC RELEASE

DISTRIBUTION IS UNLIMITED.

ROBERT A. REGAZZI

20PA10024116/5C

CAUTION: VERIFY PRIOR TO USE AT https://defenseammunitioncenter.army.mil THAT

THIS IS THE MOST CURRENT VERSION OF THIS DOCUMENT. THIS IS PAGE 1 OF 4.

JANUARY 1985

APPENDIX 5C

UNITIZATION PROCEDURES FOR

BOXED AMMUNITION AND COMPO-

NENTS ON 4-WAY ENTRY PALLETS

CARTRIDGE, 5.56MM, SAW, PACKED 800 PER PA108

METAL CONTAINER, 2 CONTAINERS PER WIRE-

BOUND BOX, UNITIZED 36 BOXES PER 40” X 48”

PALLET; APPROX BOX SIZE 17” L X 13-3/8” W X 9-

3/8” H

TEST ENGINEER

TEST

REPORT

APPROVED, COMBAT CAPABILITIES DEVELOPMENT

COMMAND ARMAMENTS CENTER

FCDD-ACE-LTP

AMSJM-MMT

APPROVED, U.S. ARMY JOINT MUNITIONS COMMAND

APPROVED BY ORDER OF COMMANDING GENERAL,

U.S. ARMY MATERIEL COMMAND

DEFENSE AMMUNITION CENTER

MADELINE BANKS JULY 2024REVISION NO. 10

SEE THE REVISION LISTING ON PAGE 2

NA

HANSSEN.JO

SEPH.W.1376

495538

Digitally signed by

HANSSEN.JOSEPH.W.

1376495538 Date: 2024.08.02 09:01:46 -05'00'

BRADLEY.PATRIC

K.LEBARRON.1294

637369

Digitally signed by

BRADLEY.PATRICK.LEBARRON

.1294637369 Date: 2024.08.02 10:08:02 -05'00'

BRAILSFORD.KEIT

H.ANTHONY.10286

55661

Digitally signed by

BRAILSFORD.KEITH.ANTHONY.

1028655661 Date: 2024.08.02 16:17:52 -05'00'

FIEFFER.LAUR

A.A.1230375727

Digitally signed by

FIEFFER.LAURA.A.1230375727

Date: 2024.06.21 10:35:53 -05'00'

FELICIANO.AD

IN.1259200373

Digitally signed by

FELICIANO.ADIN.1259200373

Date: 2024.07.10 13:18:06 -05'00'

MACE.KENT.

1056975302

Digitally signed by

MACE.KENT.1056975302

Date: 2024.07.11 12:47:26 -05'00'

PROJECT FSA 146/5C-75 DRAWING 19-48-4116/5C

PALLET UNIT DATA

ITEMS INCLUDED

*HAZARD

CLASS

AND

DIVISION

*COMPATI-

BILITY

GROUP

APPROX

WEIGHT

(LBS) NSN DODIC

1305-

01-258-8692

01-363-7560

01-252-0153

01-361-8038

01-258-8694

01-393-7050

01-393-7052

01-411-6098

01-467-3026

01-533-5663

01-533-5657

01-568-0799

01-559-3332

01-582-7502

01-596-4478

01-596-4416

01-596-4391

01-651-5896

01-715-1637

A062

A062

A064

A064

A075

AA01

AA02

AA08

AA44

AB03

AB04

AB40

AB56

AB66

AB73

AB75

AB76

AC10

AC91

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

1.4

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

S

2,790

2,790

2,790

2,790

2,178

2,708

2,726

1,782

2,790

2,790

2,790

2,790

2,790

2,754

2,790

2,790

2,790

2,754

2,815

*HAZARD CLASSIFICATION DATA CONTAINED IN THE ABOVE CHART IS FOR GUIDANCE AND INFORMATIONAL PUR- POSES ONLY. VERIFICATION OF THE SPECIFIED DATA SHOULD BE MADE BY CONSULTING THE MOST RECENT

JOINT HAZARD CLASSIFICATION SYSTEM LISTING OR OTHER APPROVED LISTING(S).

REVISION NO. 3, DATED SEPTEMBER 1993, CONSISTS OF:

1. ADDING ITEMS BY NATIONAL STOCK NUMBER TO THE “PALLET UNIT DATA" CHART.

2. ADDING ALTERNATIVE STRAPPING.

3. ADDING ALTERNATIVE FILLER ASSEMBLY.

4. COMBINING NOTES "J” (1-1/4” STRAPS) AND “K” (HORIZONTAL STRAPS).

5. ADDING NEW GENERAL NOTE "L" (ALTERNATIVE FILLER).

REVISION NO. 4, DATED DECEMBER 1994, CONSISTS OF:

1. ADDING ITEMS BY NATIONAL STOCK NUMBER TO THE "PALLET UNIT DATA” CHART.

2. CHANGING THE WEIGHT OF ITEMS ON “PALLET UNIT DATA" CHART.

3. DELETING GENERAL NOTE “N” (OUTBOARD BOX POSITION).

REVISION NO. 5, DATED MARCH 1996, CONSISTS OF:

1. ADDING ITEM BY NATIONAL STOCK NUMBER TO THE “PALLET UNIT DATA” CHART.

2. CHANGING THE WEIGHT OF AN ITEM ON THE “PALLET UNIT DATA” CHART.

3. DELETING GENERAL NOTE RELATING TO STRAP CUTTER AND RELETTERING OTHER GENERAL

NOTES.

REVISION NO. 6, DATED JANUARY 2000, CONSISTS OF:

1. ADDING ITEM BY NATIONAL STOCK NUMBER TO THE “PALLET UNIT DATA” CHART.

2. CHANGING TO NEW DRAWING FORMAT.

REVISION NO. 7, DATED NOVEMBER 2013, CONSISTS OF CHANGES PER ECP R12K2038 NOR 14:

1. ADDING ITEMS BY NATIONAL STOCK NUMBERS TO THE “PALLET UNIT DATA” CHART.

2. UPDATING TITLE IN COVER PAGE (PACKED 800 PER PA108).

3. UPDATING CALLOUTS TO REFLECT THE .029” STRAP REFERENCE.

4. UPDATING TABLE FORMAT AND WEIGHTS IN “PALLET UNIT DATA” CHART.

REVISION NO. 8, DATED MAY 2015, CONSISTS OF CHANGES PER ECP R14K9001-NOR 18:

1. ADDING ITEM BY NATIONAL STOCK NUMBER TO THE “PALLET UNIT DATA” CHART.

2. UPDATING PALLET SPECIFICATION IN GENERAL NOTE “L”.

REVISION NO. 9, DATED AUGUST 2017, CONSISTS OF CHANGES PER ECP R16S2008 NOR 7:

ADDING ITEM BY NATIONAL STOCK NUMBER TO THE “PALLET UNIT DATA” CHART

REVISION NO. 10, DATED JULY 2024, CONSISTS OF CHANGES PER ECP R24K2001 NOR 11:

ADDING ITEM BY NATIONAL STOCK NUMBER TO THE “PALLET UNIT DATA” CHART

PROJECT FSA 146/5C-75DRAWING 19-48-4116/5C

PALLET UNIT

SEE GENERAL NOTE "B" AT RIGHT.

17"

51" 40 1/8"

1 1/2" +1/2" -0

1 1/2" +1/2" -0

43"

13 3/8"

SEAL FOR 3/4" STRAPPING

(7 REQD,1 PER STRAP).

CRIMP EACH SEAL WITH

TWO PAIR OF NOTCHES.

HORIZONTAL STRAP (ALTERNATIVE

FOR LOAD STRAP), 3/4" X .035" OR

.031" OR .029" X 16'-3" LONG STEEL

STRAPPING (4 REQD). SEE GENERAL

NOTE "J" AT RIGHT.

40" X 48" PALLET 40"48"

36 BOXES OF 5.56MM CTG (1,600 PER BOX) @ 75.0 LBS - - - 2,700 LBS

DUNNAGE - - - - - - - - - - - - - - - - - - - - - - - - 10 LBS

PALLET - - - - - - - - - - - - - - - - - - - - - - - - 80 LBS

TOTAL WEIGHT - - - - - - - - - - - 2,790 LBS (APPROX)

CUBE - - - - - - - - - - - - - - - 50.9 CU FT (APPROX)

BILL OF MATERIAL

PALLET, 40” X 48” - - - - - - 1 REQD - - - - - - 80 LBS

STEEL STRAPPING, 3/4” – 103.50’ REQD - - - - - 9.24 LBS

SEAL FOR 3/4” STRAPPING - - - 7 REQD - - - - - - - - NIL

A. THIS APPENDIX CANNOT STAND ALONE BUT MUST BE

USED IN CONJUNCTION WITH THE BASIC UNITIZATION

PROCEDURES DRAWING 19-48-4116-20PA1002. TO PRO-

DUCE AN APPROVED UNIT LOAD, ALL PERTINENT PRO-

CEDURES, SPECIFICATIONS AND CRITERIA SET FORTH

WITHIN THE BASIC DRAWING WILL APPLY TO THE PRO-

CEDURES DELINEATED IN THIS APPENDIX. ANY EXCEP-

TIONS TO THE BASIC PROCEDURES ARE SPECIFIED IN

THIS APPENDIX.

B. DIMENSIONS, CUBE AND WEIGHT OF A PALLET UNIT WILL

VARY SLIGHTLY DEPENDING UPON THE ACTUAL DIMEN-

SIONS OF THE BOXES AND THE WEIGHT OF THE SPECIF-

IC ITEM BEING UNITIZED.

C. THE LOAD STRAPS MUST BE PRE-POSITIONED ON THE

PALLET DECK PRIOR TO PLACING BOXES ON THE PAL-

LET. NOTE THAT THE LOAD STRAPS WILL BE LOCATED

AS SHOWN. LOAD STRAPS MUST BE TENSIONED AND

SEALED PRIOR TO APPLICATION OF TIEDOWN STRAPS.

D. INSTALL EACH TIEDOWN STRAP TO PASS UNDER TOP

DECK BOARDS OF THE PALLET AND TO BE LOCATED AS

SHOWN. TIEDOWN STRAPS WILL NOT BE APPLIED UNTIL

THE LOAD STRAPS HAVE BEEN TENSIONED AND SEALED.

E. THE FOLLOWING AMC DRAWINGS ARE APPLICABLE FOR

OUTLOADING AND STORAGE OF THE ITEMS COVERED BY

CARLOADING - - - - 19-48-4115-5PA1002

TRUCKLOADING - - - 19-48-4117-11PA1003

STORAGE - - - - - 19-48-4118-1-2-3-4-14-

22PA1002

END OPENING ISO

CONTAINER - - - - 19-48-4153-15PA1002

MILVAN - - - - - - 19-48-4166-15PA1003

SIDE OPENING ISO

CONTAINER - - - - 19-48-4267-15PA1009

F. IF ITEMS COVERED HEREIN ARE UNITIZED PRIOR TO

ISSUANCE OF THIS REVISION TO THIS APPENDIX, THE

BOXES NEED NOT BE REUNITIZED SOLELY TO CONFORM

TO THIS REVISION.

G. THE UNITIZATION PROCEDURES DEPICTED HEREIN MAY

ALSO BE USED FOR UNITIZING 5.56MM CARTRIDGES

WHEN IDENTIFIED BY DIFFERENT NATIONAL STOCK

NUMBERS (NSN) THAN WHAT IS SHOWN ON PAGE 2,

PROVIDED THE BOX PACK DOES NOT VARY FROM WHAT

IS DELINEATED HEREIN. THE EXPLOSIVE CLASSIFICA-

TION OF OTHER ITEMS MAY BE DIFFERENT THAN WHAT

IS SHOWN.

H. 1-1/4” STRAPS MAY BE SUBSTITUTED FOR THE 3/4"

STRAPPING SPECIFIED IN THE “PALLET UNIT” AT LEFT.

THREE 1-1/4” TIEDOWN STRAPS WILL…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .