This document provides details for a federal solicitation from the Department of Veterans Affairs Technology Acquisition Center Austin. Solicitation number 36C77622B0028 is seeking proposals for infrastructure upgrades construction services at Fort Wayne to support the EHRM system. Offerors should provide pricing and plans for upgrading telecommunications and IT infrastructure as outlined in technical drawing Attachment 9 to modernize the facility's technology systems. Proposals are due by the date specified in the solicitation document. The award will be granted to a responsible offeror whose offer follows the terms of the solicitation and is determined most advantageous to the Government considering price and technical factors.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
MECH
FAMILY
ROOM
VENDING
FAMILTY
TOILET
PUBLIC
TOILET
CORRIDOR
C4109
CORRIDOR
C4110
CORRIDOR
C4111
ELEVATOR
WAITING
BUILDING
SERVICES
4164A
ELEVATOR
UTILITY
CORRIDOR
C4302
MED/SURG
BARIATRIC
PHYSICAL
DISABILITIES
MED/SURG
BATH
4332A
ALCOVE
EQUIPMENT
STORAGE
ALCOVE
CORRIDOR
C4301
CORRIDOR
C4303
NURSE
MANAGER
OFFICE
ICU NURSE
MANAGER
OFFICE
SOCIAL
WORKER
DIETICIAN
NURSE
WORKROOM
NURSE
STATION
4317 4319
ELECTRICAL
TOILET
4331 BATH
4333A
STAIR 3-4
ST4.3
CLEAN
SUPPLY
MEDICATION
ROOM
SOILED
UTILITY/EQUIP
BATH
4353A
CORRIDOR
C4108
ELECTRICAL
BATH
4312A
BATH
4316A
CLEAN LINEN
H.A.C.
NOURISHMENT
BATH
4324A
CORRIDOR
C4304
ELEVATOR
MED/SURG
ALCOVE
STORAGE
MED/SURG
MED/SURG
BATH
4320A MED/SURG
MED/SURG
BATH
4326A
BATH
4346A
BATH
4348A
MED/SURG
4346 MED/SURG
BATH
4352A
PATIENT
ROOM
INTENSIVE
CARE
ISOLATION
NOURISHMENT
4356 UP
STAIR 4-4
ST4.4
CORRIDOR
C4305
ANTEROOM
PATIENT
TOILET
INTENSIVE
CARE
4364A
ANTEROOM
PATIENT
ROOM
INTENSIVE
ISOLATION
ICU
EQUIPMENT
STORAGE
CLEAN LINEN
ROOM
CLEAN
NURSE
STATION
SOILED LINEN
CLEAN
SUPPLY
4351 PATIENT
ROOM
INTENSIVE
CARE
MEDICATION
ROOM
NURSE
STATION
PATIENT
INTENSIVE
CARE
BATH
4365A
STAFF
LOUNGE
STAFF
TOILET
SUPPLY
ROOM
KITCHENETTE
STAFF
LOUNGE
4334B
INTER-DISCIPLINARY
ROOM
4334A
M
AT
C H
LI
N
E T1
-B
M
AT
C H
LI
N
E T1
-B
MATCHLINE
T-100-D
WAP
WAP
W
2 WAP
2 2 2
2 2
2 2
4 2
WAP
WAP
WAP
2 1 2 2
2 1 2
WAP
WAP 2
2 2
2 2
W
W
W W
WAP
W
4 2
W W2
WAP
W
T1
-A T1
-A
JH
JH
JH
JH
TR-4308
POWER PANELLENEL/ALTRONIX
LG
D
U A
L IN
V
ER
TER
A
C
(N ot e:
A ll W
AO
C ab le s in a re a T1
-A to b e ro ut ed to , a nd te rm in at ed in T
R -4
8)
(N ot e:
A ll W
AO
C ab le s in a re a T1
-A to b e ro ut ed to , a nd te rm in at ed in T
R -4
8)
(N ot e:
A ll W
AO
C ab le s in a re a T1
-B to b e ro ut ed to , a nd te rm in at ed in T
R -4
8)
(N ot e:
A ll W
AO
C ab le s in a re a T1
-B to b e ro ut ed to , a nd te rm in at ed in T
R -4
8)
2 2
2 4 2 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 1 - FOURTH FLOOR
TECHNOLOGY FLOOR PLAN - AREA B
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T104B
No. REVISION DESCRIPTION DATE
SCALE: 1/8" = 1'0"
B1 - FORTH FLOOR LEVEL - TECHNOLOGY PLAN
N
11/12/2021 WAMAJS
2121 LAKE AVE,
FORT WAYNE, IN 46805
94 119
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
TECHNOLOGY KEYNOTES:
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'A' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'B' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 12"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA
OUTLET (WAO) STATION CABLES.
tiles and the floor above. If in the event that the cable tray cannot be installed , a J-Hook pathway shall be established to support the Category 6A station cables.
Note: Cable Tray Installation is contingent upon the amount of congestion evident in the space between the drop ceiling grid/
INTERSECTING CABLE TRAYS WILL BE SEPARATED VERTICALLY, SO AS TO AVOID CABLE ROUTING CONFLICTS
BETWEEN FIBER BACKBONE CABLES AND UTP STATION CABLES.
LEGEND:
VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101
FOR MORE DETAILS)
VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101
FOR MORE DETAILS)
W
WAP
WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B
(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2).
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
PROVIDE AND INSTALL 18"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA
OUTLET (WAO) STATION CABLES.
PROVIDE AND INSTALL J-HOOK PATHWAYS TO SUPPORT CATEGORY 6A STATION CABLES FROM WAO TO MAIN CABLE TRAY OR MAIN J-HOOK PATHWAY BACK TO THE ASSOCIATED TR (TYPICAL). INSTALL AT 5' (MAXIMUM) .
INTERVALS O.C. (NOTE: J-HOOK PATHWAYS DEPICTED ARE JUST A FEW EXAMPLES. ALL STATION CABLING MUST BE SUPPORTED BY J-HOOK PATHWAYS THAT ARE PARALLEL AND PERPENDICULAR TO BUILDING LINES.)
= 4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2)
CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)
X
X = PHASE 1 - THESE NEW WORK AREA OUTLET LOCATIONS (NWAO's) ARE TO BE INSTALLED IN PHASE 1.
= PHASE 2 - THESE EXISTING WORK AREA OUTLET LOCATIONS (EWAO's) ARE TO BE INSTALLED IN PHASE 2.
ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS
(IF POSSIBLE) IN GENERAL PATHWAYS.
ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS
SECONDARY BONDING BUSBAR.
AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES
WHERE CABLING WAS REMOVED.
AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE
CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
A.
B.
C.
D.
E.
F.
G.
H.
CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING
ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE
DROPS.
ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO
THE NEW CABLING.
EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.
EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN
OLTS AND AN OTDR PER THE TIER 2 STANDARD.
PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE
MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)
NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE
PATHWAYS.
I. EXISTING CONDUITS TO REMAIN.
J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
K.
L.
M.
N.
PHASE 1 - INSTALL APPROXIMATELY (42) NEW CATEGORY 6A DATA CABLES ON THE FOURTH FLOOR LEVEL TO A
MIXTURE OF (19) SINGLE, DUAL & QUAD NEW WORK AREA OUTLET LOCATIONS.
O.
INSTALLATION..
GENERAL NOTES:
NOTE: THE FORTH FLOOR WAS RECENTLY REMODELED. BID SET DRAWINGS (dated 4//27/2016) DEPICTING VOICE & DATA WORK AREA OUTLET (WAO's), ALONG WITH A NEW CABLE TRAY RUNNING EAST TO WEST DOWN THE MAIN HALLWAY, WERE PROVIDED. AS A RESULT, IT WAS DECIDED THAT AN AUDIT WOULD NOT BE NECESSARY FOR THE
FOURTH FLOOR, AND SO, THE NEW CABLE TRAY IS NOT DEPICTED ON THESE DRAWINGS.
PHASE 2 - INSTALL APPROXIMATELY (426) NEW CATEGORY 6A DATA CABLES ON THE FOURTH FLOOR LEVEL TO A
MIXTURE OF (229) SINGLE, DUAL & QUAD EXISTING WORK AREA OUTLET LOCATIONS.
P.
Willam A. McClendon - 11/12/2021
CONFERENCE
OFFICE
CLOSET
551A
STORAGE
TOILET
TOILET
ELEVATOR
MED
515D1
MENS
OFFICE
515E
UP
STAIR
5-1
MED
515D
EXAM
515C
EXAM
515B
EXAM
515A
TOILET
NURSE
STATION
WOMENS
TOILET
WAITING
OFFICE
510A
OFFICE
510B
OFFICE
CLEAN
UTILITY
STORAGE
507C
VESTIBULE
OFFICE
507A
PAIN
OFFICE
507B
MANAGEMENT
SOILED
UTILITY
ELEC
UP
ELEVATOR
STORAGE
VESTIBULE
ELEVATOR
H.A.C.
STORAGE
OFFICE
546A
OFFICE
546B 545
EXAM
OFFICE
DATA
549A
STORAGE
540 CLOSET
539A
CLEAN
SUPPLY
BATH
543A
PYXIS
CLASSROOM
MECH
SOILED
UTILITY
515F
LOCKERS
LAB
OFFICE
OFFICE
BATH
521A
EXAM
EXAM
520A
EXAM
520B OFFICE
STAIR
5-2 OFFICE
SOILED
UTILITY
EXAM
EXAM
525A
EXAM
EXAM
526A
OFFICE
WAITING
CHECK-IN
COLLAB
EXAM
EXAM
EXAM
SOILED
UTILITY
EXAM
BATH
537A
STAIR
5-3 OFFICE
EXAM
MECH
TR-528C
LEN
EL/A
LTR
O
N
IX
LG DUAL INVERTER AC
PO
W
ER
PA
N
EL
ISP FIBER OPTIC BACKBONE KEYNOTES:
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE
CABLE TRAY.
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 1 - FIFTH FLOOR
TECHNOLOGY FLOOR PLAN
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T-105
No. REVISION DESCRIPTION DATE
NOT TO SCALE (NTS)
B1 - FIFTH FLOOR - TECHNOLOGY PLAN
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE
CABLE TRAY.
PROVIDE AND INSTALL (1) EACH 12-STRAND SINGLEMODE (OS2)/
24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC
CABLE, WITH A GREEN JACKET, FOR ISP PATHWAY "A"
REDUNDANT HOMERUN TO TR-528C.
PROVIDE AND INSTALL (1) EACH 12-STRAND SINGLEMODE (OS2)/
24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC
CABLE, WITH A GREEN JACKET, FOR ISP PATHWAY "B"
REDUNDANT HOMERUN TO TR-528C.
N
11/12/2021 WAMAJS
2121 LAKE AVE,
FORT WAYNE, IN 46805
11995Willam A. McClendon - 11/12/2021 96 OF 120
CONFERENCE
OFFICE
CLOSET
551A
STORAGE
TOILET
TOILET
ELEVATOR
MED
515D1
MENS
OFFICE
515E
UP
STAIR
5-1
MED
515D
EXAM
515C
EXAM
515B
EXAM
515A
TOILET
NURSE
STATION
WOMENS
TOILET
WAITING
OFFICE
510A
OFFICE
510B
OFFICE
CLEAN
UTILITY
STORAGE
507C
VESTIBULE
OFFICE
507A
PAIN
OFFICE
507B
MANAGEMENT
SOILED
UTILITY
ELEC
UP
ELEVATOR
ELEVATOR
MECH
SOILED
UTILITY
515F
LOCKERS
LAB
OFFICE
OFFICE
BATH
521A
EXAM
EXAM
520A
EXAM
520B OFFICE
STAIR
5-2 OFFICE
SOILED
UTILITY
EXAM
EXAM
525A
EXAM
EXAM
526A
OFFICE
WAITING
CHECK-IN
MECH
2 2 2
2 4 2 2
2 2
2 2 2
2 2 2
2 2
M
AT
C H
LI
N
E T1
-B
M
AT
C H
LI
N
E T1
-B
T1
-A T1
-A
JH
JH
JH
TR-528C
LEN
EL/A
LTR
O
N
IX
LG DUAL INVERTER AC
PO
W
ER
PA
N
EL
(N ot e:
A ll W
AO
C ab le s in a re a T1
-A to b e ro ut ed to , a nd te rm in at ed in T
R -5
C
(N ot e:
A ll
W
AO
C ab le s in a re a
T1
-A to b e ro ut ed to
, a nd te rm in at ed in
T R
-5
C
(N ot e:
A ll W
AO
C ab le s in a re a T1
-B to b e ro ut ed to , a nd te rm in at ed in T
R -5
C
(N ot e:
A ll W
AO
C ab le s in a re a T1
-B to b e ro ut ed to , a nd te rm in at ed in T
R -5
C th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 1 - FIFTH FLOOR
TECHNOLOGY FLOOR PLAN - AREA A
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T105A
No. REVISION DESCRIPTION DATE
SCALE: 1/8" = 1'0"
B1 - FIFTH FLOOR - TECHNOLOGY PLAN
N
11/12/2021 WAMAJS
2121 LAKE AVE,
FORT WAYNE, IN 46805
96 119
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
TECHNOLOGY KEYNOTES:
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'A' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'B' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 12"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA
OUTLET (WAO) STATION CABLES.
tiles and the floor above. If in the event that the cable tray cannot be installed , a J-Hook pathway shall be established to support the Category 6A station cables.
Note: Cable Tray Installation is contingent upon the amount of congestion evident in the space between the drop ceiling grid/
INTERSECTING CABLE TRAYS WILL BE SEPARATED VERTICALLY, SO AS TO AVOID CABLE ROUTING CONFLICTS
BETWEEN FIBER BACKBONE CABLES AND UTP STATION CABLES.
LEGEND:
VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101
FOR MORE DETAILS)
VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101
FOR MORE DETAILS)
ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS
(IF POSSIBLE) IN GENERAL PATHWAYS.
ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS
SECONDARY BONDING BUSBAR.
AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES
WHERE CABLING WAS REMOVED.
AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE
CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
A.
B.
C.
D.
E.
F.
G.
H.
CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING
ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE
DROPS.
ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO
THE NEW CABLING.
EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.
EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN
OLTS AND AN OTDR PER THE TIER 2 STANDARD.
PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE
MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)
NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE
PATHWAYS.
I. EXISTING CONDUITS TO REMAIN.
J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
K.
L.
M.
N.
PHASE 1 - INSTALL APPROXIMATELY (34) NEW CATEGORY 6A DATA CABLES ON THE FIFTH FLOOR LEVEL TO A MIXTURE
OF (14) DUAL AND QUAD NEW WORK AREA OUTLET LOCATIONS.
O.
W
WAP
WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B
(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2).
INSTALLATION..
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
GENERAL NOTES:
PROVIDE AND INSTALL 18"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA
OUTLET (WAO) STATION CABLES.
PROVIDE AND INSTALL J-HOOK PATHWAYS TO SUPPORT CATEGORY 6A STATION CABLES FROM WAO TO MAIN CABLE TRAY OR MAIN J-HOOK PATHWAY BACK TO THE ASSOCIATED TR (TYPICAL). INSTALL AT 5' (MAXIMUM) .
INTERVALS O.C. (NOTE: J-HOOK PATHWAYS DEPICTED ARE JUST A FEW EXAMPLES. ALL STATION CABLING MUST BE SUPPORTED BY J-HOOK PATHWAYS THAT ARE PARALLEL AND PERPENDICULAR TO BUILDING LINES.)
= 4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2)
CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)
X
X = PHASE 1 - THESE NEW WORK AREA OUTLET LOCATIONS (NWAO's) ARE TO BE INSTALLED IN PHASE 1.
= PHASE 2 - THESE EXISTING WORK AREA OUTLET LOCATIONS (EWAO's) ARE TO BE INSTALLED IN PHASE 2.
PHASE 2 - INSTALL APPROXIMATELY (170) NEW CATEGORY 6A DATA CABLES ON THE FIFTH FLOOR LEVEL TO A MIXTURE
OF (80) DUAL AND QUAD EXISTING WORK AREA OUTLET LOCATIONS.
P.
Willam A. McClendon - 11/12/2021
OFFICE
CLOSET
551A
TOILET
TOILET
ELEVATOR
ELEC
UP
ELEVATOR
STORAGE
VESTIBULE
ELEVATOR
H.A.C.
STORAGE
OFFICE
546A
OFFICE
546B 545
EXAM
OFFICE
DATA
549A
STORAGE
540 CLOSET
539A
CLEAN
SUPPLY
BATH
543A
PYXIS
CLASSROOM
WAITING
CHECK-IN
COLLAB
EXAM
EXAM
EXAM
SOILED
UTILITY
EXAM
BATH
537A
STAIR
5-3 OFFICE
EXAM
2 2
2 24
M
AT
C H
LI
N
E T1
-B
M
AT
C H
LI
N
E T1
-B
T1
-A T1
-A
JHJH JH JH JH
JH
JH
JH
JH
JH
LEN
EL/A
LTR
O
N
IX
LG DUAL INVERTER AC
PO
W
ER
PA
N
EL
(N ot e:
A ll W
AO
C ab le s in a re a T1
-A to b e ro ut ed to , a nd te rm in at ed in T
R -5
C
(N ot e:
A ll
W
AO
C ab le s in a re a
T1
-A to b e ro ut ed to
, a nd te rm in at ed in
T R
-5
C
(N ot e:
A ll W
AO
C ab le s in a re a T1
-B to b e ro ut ed to , a nd te rm in at ed in T
R -5
C
(N ot e:
A ll W
AO
C ab le s in a re a T1
-B to b e ro ut ed to , a nd te rm in at ed in T
R -5
C
2 2 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 1 - FIFTH FLOOR
TECHNOLOGY FLOOR PLAN - AREA B
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T105B
No. REVISION DESCRIPTION DATE
SCALE: 1/8" = 1'0"
B1 - FIFTH FLOOR - TECHNOLOGY PLAN
N
11/12/2021 WAMAJS
2121 LAKE AVE,
FORT WAYNE, IN 46805
97 119
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
TECHNOLOGY KEYNOTES:
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'A' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC
BACKBONE 'B' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)
PROVIDE AND INSTALL 12"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA
OUTLET (WAO) STATION CABLES.
tiles and the floor above. If in the event that the cable tray cannot be installed , a J-Hook pathway shall be established to support the Category 6A station cables.
Note: Cable Tray Installation is contingent upon the amount of congestion evident in the space between the drop ceiling grid/
INTERSECTING CABLE TRAYS WILL BE SEPARATED VERTICALLY, SO AS TO AVOID CABLE ROUTING CONFLICTS
BETWEEN FIBER BACKBONE CABLES AND UTP STATION CABLES.
LEGEND:
VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101
FOR MORE DETAILS)
VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101
FOR MORE DETAILS)
ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS
(IF POSSIBLE) IN GENERAL PATHWAYS.
ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS
SECONDARY BONDING BUSBAR.
AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES
WHERE CABLING WAS REMOVED.
AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE
CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
A.
B.
C.
D.
E.
F.
G.
H.
CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING
ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE
DROPS.
ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO
THE NEW CABLING.
EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.
EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN
OLTS AND AN OTDR PER THE TIER 2 STANDARD.
PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE
MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)
NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE
PATHWAYS.
I. EXISTING CONDUITS TO REMAIN.
J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
K.
L.
M.
N.
PHASE 1 - INSTALL APPROXIMATELY (34) NEW CATEGORY 6A DATA CABLES ON THE FIFTH FLOOR LEVEL TO A MIXTURE
OF (14) DUAL AND QUAD NEW WORK AREA OUTLET LOCATIONS.
O.
W
WAP
WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B
(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2).
INSTALLATION..
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)
GENERAL NOTES:
PROVIDE AND INSTALL 18"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA
OUTLET (WAO) STATION CABLES.
PROVIDE AND INSTALL J-HOOK PATHWAYS TO SUPPORT CATEGORY 6A STATION CABLES FROM WAO TO MAIN CABLE TRAY OR MAIN J-HOOK PATHWAY BACK TO THE ASSOCIATED TR (TYPICAL). INSTALL AT 5' (MAXIMUM) .
INTERVALS O.C. (NOTE: J-HOOK PATHWAYS DEPICTED ARE JUST A FEW EXAMPLES. ALL STATION CABLING MUST BE SUPPORTED BY J-HOOK PATHWAYS THAT ARE PARALLEL AND PERPENDICULAR TO BUILDING LINES.)
= 4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2)
CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)
X
X = PHASE 1 - THESE NEW WORK AREA OUTLET LOCATIONS (NWAO's) ARE TO BE INSTALLED IN PHASE 1.
= PHASE 2 - THESE EXISTING WORK AREA OUTLET LOCATIONS (EWAO's) ARE TO BE INSTALLED IN PHASE 2.
PHASE 2 - INSTALL APPROXIMATELY (170) NEW CATEGORY 6A DATA CABLES ON THE FIFTH FLOOR LEVEL TO A MIXTURE
OF (80) DUAL AND QUAD EXISTING WORK AREA OUTLET LOCATIONS.
P.
Willam A. McClendon - 11/12/2021 98 OF 120
UP
BATH
ROOM
DN
LOCKER
TOILET
ROOM
UP
STORAGE
HVAC SHOP
UP
UP
CARP SHOP
CARP SHOP
GARAGE
PIPE SHOP
211A
UP
ROOM
OFFICE
BREAK
ROOM
OFFICE
OFFICE
4 4 4
U P
U P
4 U P
U P
LO
C
KS
M
IT
H
5A
PA
IN
T
SH
O P
U P
BASEMENT 1ST FLOOR
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 2 - TECHNOLOGY FLOOR PLANS
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T-106
No. REVISION DESCRIPTION DATE
SCALE: 1/8" = 1'0"
B2 - TECHNOLOGY PLAN
N
11/12/2021 WBM
ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS
(IF POSSIBLE) IN GENERAL PATHWAYS.
ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS
SECONDARY BONDING BUSBAR.
AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES
WHERE CABLING WAS REMOVED.
AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE
CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
A.
B.
C.
D.
E.
F.
G.
H.
CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING
ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE
DROPS.
ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO
THE NEW CABLING.
EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.
EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN
OLTS AND AN OTDR PER THE TIER 2 STANDARD.
PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE
MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)
NEW FIRE-RATED SLEEVES SHALL BE INSTALLED LEAVING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE
PATHWAYS.
GENERAL NOTES:
I. EXISTING CONDUITS TO REMAIN.
J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
K.
L.
M.
N.
INSTALL APPROXIMATELY (58) NEW CATEGORY 6A DATA CABLES IN BUILDING 2 TO A MIXTURE OF (15) DUAL & QUAD
WORK AREA OUTLET LOCATIONS.
O.
LEGEND:
W
WAP
WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6 UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
INSTALLATION.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
AJS
PROVIDE AND INSTALL (1) NEW 4" EMT FROM PULL BOX INTO THE TR. ROUTE CONDUIT THROUGH CRAWL SPACE AND ATTACH TO BUILDING STRUCTURE ALONG THE ROUTE. PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERUCT (e.g.: MAXCELL)
PROVIDE AND INSTALL (1) NEW NEMA 3R PULL BOX (18"W x 18"L x 12"D).
PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED, OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET. REDUNDANT/DIVERSE FIBER CABLE "A" SHALL BE HOMERUN BACK TO THE NEW
MCR/DC/SR IN BUILDING 1.
PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED, OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET. REDUNDANT/DIVERSE FIBER CABLE "B" SHALL BE HOMERUN BACK TO THE NEW
MCR/DC/SR IN BUILDING 1.
EXISTING CONDUIT, FROM EXISTING MAINTENANCE HOLE (MH), CONTAINING EXISTING COPPER & FIBER FEED CABLES. REMOVE EXISTING FEED CABLES BACK TO EXISTING MH . EXTEND EXISTING CONDUIT INTO NEW TR LOCATION. PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERDUCT (e.g.: MAXCELL) FROM EXISTING MH INTO TR.
LEGEND:
2121 LAKE AVE,
98 119Willam A. McClendon - 11/12/2021 99 OF 120
H.A.C.
120 119A
OFFICE
VEST
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
BREAK/COPY
UP
MECH
OFFICE
WOMEN
TOILET
MEN TOILET
OFFICE
103A
VEST
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
UP UP
UP
4 4
4 4
4 4 4 4 4
4 4
BASEMENT 1ST FLOOR
LEN
EL/A
LTR
O
N
IX
LG
D
U A
L IN
V
ER
TER
A
C
BASEMENT
TR-301
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELECOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 3 - TECHNOLOGY FLOOR PLAN
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T-107
No. REVISION DESCRIPTION DATE
SCALE: 1/8" = 1'0"
B3 - TECHNOLOGY PLAN
N
11/12/2021 WBM
ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS
(IF POSSIBLE) IN GENERAL PATHWAYS.
ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS
SECONDARY BONDING BUSBAR.
AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES
WHERE CABLING WAS REMOVED.
AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE
CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
A.
B.
C.
D.
E.
F.
G.
H.
CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING
ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE
DROPS.
ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO
THE NEW CABLING.
EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.
EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL.. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN
OLTS AND AN OTDR PER THE TIER 2 STANDARD.
PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE
MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)
NEW FIRE-RATED SLEEVES SHALL BE INSTALLED LEAVING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE
PATHWAYS.
GENERAL NOTES:
I. EXISTING CONDUITS TO REMAIN.
J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
K.
L.
M.
N.
INSTALL APPROXIMATELY (114) NEW CATEGORY 6A DATA CABLES IN BUILDING 3 TO A MIXTURE OF (29) DUAL & QUAD
WORK AREA OUTLET LOCATIONS.
O.
LEGEND:
W
WAP
WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6 UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
INSTALLATION.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
AJS
PROVIDE AND INSTALL (1) NEW 4" EMT FROM PULL BOX INTO THE TR. ROUTE CONDUIT THROUGH CRAWL SPACE AND ATTACH TO BUILDING STRUCTURE ALONG THE ROUTE. PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERUCT (e.g.: MAXCELL)
PROVIDE AND INSTALL (1) NEW NEMA 3R PULL BOX (18"W x 18"L x 12"D).
PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED, OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET. REDUNDANT/DIVERSE FIBER CABLE "A" SHALL BE HOMERUN BACK TO THE NEW
MCR/DC/SR IN BUILDING 1.
PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED, OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET. REDUNDANT/DIVERSE FIBER CABLE "B" SHALL BE HOMERUN BACK TO THE NEW
MCR/DC/SR IN BUILDING 1.
EXISTING CONDUIT, FROM EXISTING MAINTENANCE HOLE (MH), CONTAINING EXISTING COPPER & FIBER FEED CABLES. REMOVE EXISTING FEED CABLES BACK TO EXISTING MH . EXTEND EXISTING CONDUIT INTO NEW TR LOCATION. PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERDUCT (e.g.: MAXCELL) FROM EXISTING MH INTO TR.
KEYNOTES:
2121 LAKE AVE,
99 119Willam A. McClendon - 11/12/2021 100 OF 120
MECH/HAC
CONFERENCE
COPY/BREAK
OFFICE
OFFICE
OFFICE
STORAGE
OFFICE
CONFERENCE
OFFICE
U P
D N
U P
U P
4 4
TR-401
LE
N
EL
/A
LT
R O
N
IX
LG DUAL INVERTER AC
BASEMENT
BASEMENT 1ST FLOOR
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
TELCOMMUNICATIONS
ASPEN ENGINEERING & CONTRACTING
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
BUILDING 4 - TECHNOLOGY FLOOR PLAN
BID DOCUMENTS
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
610A4-21-701
VANIHCS
T-108
No. REVISION DESCRIPTION DATE
SCALE: 1/8" = 1'0"
B4 - TECHNOLOGY PLAN
N
11/12/2021 WBM
ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS
(IF POSSIBLE) IN GENERAL PATHWAYS.
ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS
SECONDARY BONDING BUSBAR.
AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES
WHERE CABLING WAS REMOVED.
AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE
CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.
A.
B.
C.
D.
E.
F.
G.
H.
CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING
ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE
DROPS.
ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO
THE NEW CABLING.
EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.
EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.
LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN
OLTS AND AN OTDR PER THE TIER 2 STANDARD.
PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE
MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)
NEW FIRE-RATED SLEEVES SHALL BE INSTALLED LEAVING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE
PATHWAYS.
GENERAL NOTES:
I. EXISTING CONDUITS TO REMAIN.
J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.
K.
L.
M.
N.
INSTALL APPROXIMATELY (58) NEW CATEGORY 6A DATA CABLES IN BUILDING 4 TO A MIXTURE OF (15) DUAL & QUAD
WORK AREA OUTLET LOCATIONS.
O.
LEGEND:
W
WAP
WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.
INSTALLATION.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME
TO BE T568B.
AJS
PROVIDE AND INSTALL (1) NEW 4" EMT FROM PULL BOX INTO THE TR. ROUTE CONDUIT THROUGH CRAWL SPACE AND ATTACH TO BUILDING STRUCTURE ALONG THE ROUTE. PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERUCT (e.g.: MAXCELL)
PROVIDE AND INSTALL (1) NEW NEMA 3R PULL BOX (18"W x 18"L x 12"D).
PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED, OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET. REDUNDANT/DIVERSE FIBER CABLE "A" SHALL BE HOMERUN BACK TO THE NEW
MCR/DC/SR IN BUILDING 1.
PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED, OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET. REDUNDANT/DIVERSE FIBER CABLE "B" SHALL BE HOMERUN BACK TO THE NEW
MCR/DC/SR IN BUILDING 1.
EXISTING CONDUIT, FROM EXISTING MAINTENANCE HOLE (MH), CONTAINING EXISTING COPPER & FIBER FEED CABLES. REMOVE EXISTING FEED CABLES BACK TO EXISTING MH . EXTEND EXISTING CONDUIT INTO NEW TR LOCATION. PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERDUCT (e.g.: MAXCELL) FROM EXISTING MH INTO TR.
KEYNOTES:
2121 LAKE AVE,
100 119Willam A. McClendon - 11/12/2021 101 OF 120
105 107
OFFICE
OFFICE
104 102
BATH
OFFICE
UP
UP
UP
UP
4 4
CLOSET
CLOSET
OFFICE
OFFICE
H.A.C.
OFFICE
UP BATH
UP
1ST FLOOR
2ND FLOOR
BASEMENT
BASEMENT
UP
TR-501BASEMENT
LG
D
U A L
IN
V
ER
TE
R A
C
LENEL/ALTRONIX
th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t
A
B
C
D
E
F
Veterans Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project NumberCONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG.