Attachment 3 Drawing 03_ENVIRONMENTAL.pdf
PDF 2 MB Posted
- Attached to
- Y1DA--610A4-21-701 EHRM Infrastructure Upgrades Construction Ft. Wayne Federal contract opportunity
- Solicitation number
- 36C77622B0028
About this file
This solicitation from the Department of Veterans Affairs seeks hazardous material abatement and infrastructure upgrade construction services at multiple buildings located at the Veterans Affairs Medical Center campus in Fort Wayne, Indiana. Key scope of work includes removing asbestos flooring and pipe insulation; enclosing contaminated soil; and addressing lead-based paint on doors, windows and other building components. The solicitation provides extensive drawings and notes outlining the locations and types of hazardous materials throughout the buildings, as well as requirements for their safe removal or enclosure. Response due date is not specified.
View the file
Other files for this federal contract opportunity
Show all 28
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
t h r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
HAZARDOUS MATERIALS GENERAL
INFORMATION
CD
9 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA000
1, 2, 3, 4, 5, 6, T4, T5, T6
No. REVISION DESCRIPTION DATE
GENERAL NOTES
ALL ACM ABATEMENT OR ENCLOSURE WORK SHALL BE PERFORMED BY TRAINED/LICENSED ASBESTOS ABATEMENT CONTRACTOR WITHIN A FULL CONTAINMENT UNDER NEGATIVE PRESSURE (NPE).
ALL HVAC AIR INTAKES WITHIN NPE SHALL BE SHUT DOWN AND ISOLATED WITH CRITICAL BARRIERS DURING ACTIVE ACM REMOVAL OR ENCLOSURE WORK. WORK TO BE SCHEDULED WITH GENERAL CONTRACTOR AND OWNER TO
ACCOMMODATE CONSTRUCTION AND FACILITY REQUIREMENTS.
WHERE NEGATIVE PRESSURE ENCLOSURES ARE WITHIN OPERATIONAL TR ROOMS, CONTRACTOR TO MAINTAIN COOLING AIR FLOW TO ELECTRONICS BY TUNNELING METHODS OR SIMILAR.
WORKERS PERFORMING ACM REMOVAL OR ENCLOSURE SHALL DON, AT MINIMUM, HALF FACE AIR PURIFYING RESPIRATORS WITH P100 FILTERS, DISPOSABLE DUST SUITS (WITH BOOT COVERS) AND GLOVES DURING ACTIVE TASKS, WHICH SHALL
BE SUPPLEMENTED WITH USE OF POWERED AIR PURIFYING RESPIRATORS.
ACM REMOVAL WORK AREAS SHALL BE PREPARED IN ACCORDANCE WITH THE FOLLOWING: A) ALL FLOORS, CEILINGS AND WALLS SHALL BE ISOLATED USING 2-LAYERS OF 6-MIL POLY SHEETING; B) OSHA ASBESTOS SIGNAGE AT ENTRANCE TO
REGULATED AREAS; C)SINGLE-POINT OF ENTRY WITH 3-STAGE WET DECONTAMINATION STATION TO ALLOW WORKERS TO REMOVE PPE, WASH AND VACUUM THEMSELVES OFF PRIOR TO EXITING THE REGULATED WORK AREA; D) MAINTAINED
UNDER NEGATIVE PRESSURE (-0.02 IN WG OR BETTER) USING HEPA FILTERED AIR MACHINES WITH EXHAUST ROUTED TO OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR; F) CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS TO CHANGE
INTO STREET CLOTHES (OPAQUE POLY REQUIRED AS NEEDED FOR PRIVACY); G) RENEWABLE ADHESIVE MATS IMMEDIATELY OUTSIDE OF REGULATED WORK AREA TO ENSURE FOOT TRAFFIC DOES NOT SPREAD DUST/DEBRIS TO OTHER AREAS
OF FACILITY.
ACM WORK TO BE PERFORMED USING THE FOLLOWING CONTROLS: A) HEPA FILTERED VACUUM FOR CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL REMOVAL MEANS/TOOLS ARE ALLOWED TO DISTURB ACM (MECHANICAL TOOLS
PROHIBITED FOR ACM REMOVAL).
REGULATED WORK AREA IS TO BE CLEANED BY CONTRACTOR FOLLOWING COMPONENT REMOVAL USING STANDARD HEPA VACUUM & WET WIPING METHODS AND VISUALLY INSPECTED AND CLEARANCE SAMPLED BY VA REPRESENTATIVE TO
VERIFY COMPLETION OF SCOPE.
VPIH IS TO BE RESPONSIBLE FOR PERIMETER AIR MONITORING AND FINAL CLEARANCE AIR SAMPLING/VISUAL INSPECTION REQUIREMENTS.
CONTRACTOR TO BE RESPONSIBLE FOR OSHA EMPLOYEE EXPOSURE MONITORING REQUIREMENTS.
ALL WASTE PRODUCED DURING REMEDIATION PHASE SHALL BE COLLECTED, CONTAINERIZED, LABELED, CHARACTERIZED AND DISPOSED IN ACCORDANCE WITH SPECIFICATION 02.82.11
ALL WASTE CONTAINERS, EQUIPMENT, ETC. SHALL BE WET WIPED PRIOR TO LEAVING REGULATED WORK AREA.
NIGHTS WORK IS TO BE PERFORMED DURING OFF HOURS FROM 5:00 PM - 7:00 AM MONDAY THROUGH FRIDAY AND WEEKEND WORK FRIDAY 6 PM THROUGH SUNDAY. WORK IS PROHIBITED ON FEDERAL HOLIDAYS.
ASBESTOS RELATED MATERIALS ARE PRESENT AND MAY NOT SHOWN ON DRAWINGS FOR CLARITY. KNOWN ASBESTOS MATERIALS INCLUDE FIRE DOORS, SOILS, DOOR AND WINDOW CAULKS, WINDOWS GLAZING, FLOOR TILE GROUPS AND
ASSOCIATED UNDERLYING ASBESTOS MASTIC, FOUNDATION WATERPROOFING, TRANSITE AT WINDOW CONVECTORS, ASBESTOS DRYWALL ADHESIVES WHERE APPLIED TO WALL BLOCKS, GREEN MARBLE WALL PANELS, ACOUSTICAL LOBBY
PLASTER, BLACK OR WHITE DUCT SEAM SEALANTS AND APPLICATIONS, SINK SOUND PROOFING, VIBRATION ISOLATION DUCT JOINTS, ASBESTOS PIPE INSULATION AND MUDDED FITTINGS, AND GALBESTOS COATED DUCTWORK. PROTECT AS
NECESSARY.
AT INTERIOR REGULATED AREAS (NPE), WHERE THE COMBINED FOOTPRINT OF WORK CHAMBER, DECONTAMINATION CHAMBERS AND LOADOUT DOES NOT FIT WITHIN THE ROOM, THE DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2
WIDTH OF THE HALLWAY AS REQUIRED TO ALLOW PASSAGE IN CORRIDOR.
WORK AREAS ARE TO BE COORDINATED TO FACILITATE OVERALL PROJECT NEEDS. THROUGHOUT BUILDING 1, CONTRACTOR IS LIMITED TO 7 NPE FOOTPRINTS IN VARIOUS STAGES AND AT LOCATIONS OF SOLE INTEREST AND DISCRETION OF
THE VACOR. ADHERENCE TO SCHEDULING AND COMPLETION WILL BE REQUIRED FOR CONDUCT OF WORK, WITH ADDED EMPHASIS WHERE WORK IS PERFORMED IN DIAGNOSTICS AREAS.
HAZARDOUS MATERIALS INSPECTIONS WHERE PERFORMED WERE PREDOMINATELY AROUND THE EXISTING DATA SYSTEM PATHWAYS, +-4 FT.
ASBESTOS PIPE INSULATION REMNANTS WERE GENERALLY OBSERVED WHERE SLEEVED OR PASSING THROUGH WALLS, FLOORS, AND CEILINGS. ASBESTOS PIPE INSULATION IS GENERALLY PRESENT AT HISTORIC PIPE CHASES AND CEILING
AREA ALONG EXTERIOR WALL .
BLACK MASTIC IS LIKELY PRESENT UNDERLYING NEWER NON-ACM FLOORING THROUGH BUILDING 1.
PATHWAYS ARE PRESENT ABOVE CEILING GRID GENERALLY AVOID IMPACT TO LBP MATERIALS. REUSE SURFACE MOUNTED JACK FIXTURE/SYSTEMS WHERE PRESENTLY INSTALLED.
ASSUME ALL 4"X4" CERAMIC WALL GLAZE CONTAINS LEAD. DO NOT IMPACT THESE MATERIALS, LOCATIONS ARE GENERALLY NOT SHOWN. LPB DOOR, DOOR FRAMES, WINDOW ELEMENTS HANDRAILS, STRUCTURAL STEEL,, METAL STAIR SYSTEMS
ARE GENERALLY NOT SHOWN, DO NOT DISTURB.
OTHER ACM MATERIALS ARE PRESENT AND GENERALLY NOT SHOWN FOR CLARITY PURPOSES AND/OR NOT THOUGHT TO BE IMPACTED BY PROJECT INCLUDE, TERRAZZO FLOORS, UNDER-SINK COATINGS, FLOOR TILES UNDERLYING OTHER
NON-ACM FLOORING, BLACK MASTIC UNDERLYING NON-ACM FLOORING, CAULK AT DOOR FRAMES, ELEVATOR AND DUMBWAITER DOORS, ROOF SYSTEM/TARS, BLACK TAR ON EXTERIOR WALL OR CHASES, BLACK TAR ON HVAC DUCTS UNDERLING
INSULATION, WINDOW ASSEMBLIES AND BLACK TAR OR TRANSITE WITHIN HEAT CONVECTOR WALL POCKETS.
BID DOCUMENTS
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - BASEMENT -
ENVIRONMENTAL HAZARDS
CD
10 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA100
No. REVISION DESCRIPTION DATE
N
BLDG 1 - BASEMENT PLAN
A5
A9
A5
A9
A4
A6
A5
A9
A9
A5
A9
A6A8
A6 A6
A9
A9
A6
A6
A9
A6
A6
A8
A6
A6
A6
A1
A6
A2
L1
A2
L1
A3
L6
A11
A1
L5
L6
A5
L4
L4
L2
A5
A5
A5
A6
L2
L5
A6
A7
L2
L2
A6
A6
A6
A6
A6
A6
A6
A9
A9
A6
A5
A6
A5
A6
A5
A6
A5
A6
A5
A6
A5
A13
A5
A12L5
A4
A5
A5
A5
A5
A5
A5
A5
A10
L3
A10
A5
A5
A5A5
A5
A5
A5
A5
A6
A5
A6
A5
A6
A5
A6
A5
REMOVE ASBESTOS FLOOR TILE AND
UNDERLYING ASBESTOS BLACK MASTIC USING
MANUAL MEANS WITHIN A NEGATIVE PRESSURE
ENCLOSURE, 2 ENCLOSURES, 520SF
REMOVE WINDOW GLASS WITH ASBESTOS
GLAZING AND RESIDUE, USING MANUAL MEANS
WITHIN A NEGATIVE PRESSURE ENCLOSURE.
PROVIDE A TEMPORARY FALL PROTECTION
COVER , 2 WINDOW SYSTEMS.
REMOVE ASBESTOS PIPE FITTINGS AND
ASSOCIATED PIPE INSULATION USING GLOVEBAG
METHODS WITHIN A NEGATIVE PRESSURE
ENCLOSURE, 36 LF
REMOVE CEILING TILES AND REPAIR DAMAGED
ASBESTOS PIPE INSULATION, FITTINGS, AND/OR
OPEN JOINTS WITHIN A NEGATIVE PRESSURE
CONTAINMENT. PERFORM WORK IN HALLWAYS
ON NIGHTS AND WEEKENDS. REMOVE
CONTAMINATED CEILING TILES, APPLY TWO
LAYERS OF COVERING LAG CLOTH OVER
DAMAGE/DEFECTS, 4 ENCLOSURES, 8 DEFECTS
WITHIN EACH CONTAINMENT, 256 SF CEILING
TILES.
ASBESTOS PIPE INSULATION AND/OR MUDDED
FITTINGS PRESENT, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION INTERMITTENTLY
PRESENT THROUGHOUT AND WITHIN WALL
CHASES
PRIOR TO REMOVAL OF CEILING GRID, AREA TO
BE INSPECTED FOR ASBESTOS PIPE INSULATION
DAMAGE BY A LICENSED ASBEST0S INSPECTOR.
WHERE DAMAGED IS VERIFIED, PERFORM WORK
IN ACCORDANCE WITH KEYNOTE A2. WHICH
REQUIRES CEILING GRID REMOVAL AND REPAIRS
TO BE PERFORMED WITHIN A NEGATIVE
PRESSURE ENCLOSURE, 3 ENCLOSURES, 24
DEFECTS, 192 SF CEILING TILE
USING MANUAL MEANS, REMOVE ASBESTOS
CONTAMINATION ON VCT BLOCK WITHIN
NEGATIVE PRESSURE CONTAINMENT, 5 SF
ON NIGHTS AND WEEKENDS, REMOVE
NON-ASBESTOS WALL PLASTER AND BLOCKS
WITH LBP USING MANUAL MEANS AND ASBESTOS
PIPE INSULATION AND MUDDED FITTINGS USING
GLOVEBAG METHODS IN A NEGATIVE PRESSURE
ENCLOSURE, 150 SF AND 70 LF.
ASBESTOS FLOOR TILE WITH UNDERLYING
ASBESTOS BLACK MASTIC PRESENT, PROTECT
AS NECESSARY.
ASBESTOS DOOR,FRAME, AND ASSOCIATED
CAULKS. PROTECT AS NECESSARY.
ASBESTOS WATERPROOFING AT BELOW GRADE
FOUNDATION (PACM), PROTECT AS NECESSARY.
REMNANT ASBESTOS BLACK MASTIC
INTERMITTENTLY ON HVAC DUCT, PROTECT AS
NECESSARY
DAMAGED ASBESTOS PIPE FITTINGS, DO NOT
REMOVE CEILING TILES, PROTECT AS
NECESSARY
REMOVE WINDOW ASSEMBLIES WITH LBP WITHIN
A NEGATIVE PRESSURE ENCLOSURE, 2 WINDOW
ASSEMBLIES
LEAD CONTAINING YELLOW CERAMIC WALL
BLOCKS PRESENT, USE EXISTING PATHWAYS,
PROTECT AS NECESSARY.
LEAD CONTAINING 4" X 4" WALL TILES PRESENT,
DO NOT DISTURB, PROTECT AS NECESSARY. USE
NON INVASIVE SURFACE MOUNT WALL DATA
JACK SYSTEM WITH ADHESIVE OR SIMILAR. USE
EXISTING SLEEVES THROUGH CERAMIC WALL
TILES WHERE PRESENT.
BEIGE LBP PRESENT ON HANDRAILS, PIPE,
DUCTWORK AND STRUCTURAL STEEL. USE
MECHANICAL CLAMPS FOR SUPPORT WHERE
NECESSARY.
LBP DOORS, DOOR FRAMES, STRUCTURAL STEEL,
METAL STAIR SYSTEM COMPONENTS, TYPICAL
THROUGHOUT. PROTECT AS NECESSARY.
REMOVE DOOR AND FRAME WITH LBP IN A
NEGATIVE PRESSURE ENCLOSURE, 2 DOORS AND
ASSOCIATED FRAMES
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT
NEGATIVE PRESSURE ENCLOSURE WITH
NEGATIVE AIR MACHINE AND 3-STAGE DECON
KEY NOTES
A11 A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
L1
L2
L3
L4
L5
L6
A12
A13
A6
A6
A4
A8
A4
BID DOCUMENTS
A9
A7
AutoCAD SHX Text 1/16" = 1'-0" r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - FIRST FLOOR -
ENVIRONMENTAL HAZARDS
CD
11 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA101
No. REVISION DESCRIPTION DATE
A1
KEY NOTES
REMOVE CEILING TILES AND REPAIR DAMAGED
ASBESTOS PIPE INSULATION, FITTINGS, AND/OR
OPEN JOINTS WITHIN A NEGATIVE PRESSURE
CONTAINMENT. PERFORM WORK IN HALLWAYS
ON NIGHTS AND WEEKENDS. REMOVE
CONTAMINATED CEILING TILES, APPLY TWO
LAYERS OF COVERING LAG CLOTH OVER
DAMAGE/DEFECTS, 3 ENCLOSURES, 8 DEFECTS
WITHIN EACH CONTAINMENT, 400 SF CEILING
TILES
ON NIGHTS AND WEEKENDS, REMOVE CEILING
TILES AND ASBESTOS PIPE INSULATION AND
MUDDED FITTINGS USING GLOVEBAG METHODS
IN A NEGATIVE PRESSURE ENCLOSURE, 1
ENCLOSURE , 10 LF AND 50SF CEILING TILES.
PRIOR TO REMOVAL OF CEILING GRID, AREA TO
BE INSPECTED FOR ASBESTOS PIPE INSULATION
DAMAGE BY A LICENSED ASBEST0S INSPECTOR.
WHERE DAMAGED IS VERIFIED, PERFORM WORK
IN ACCORDANCE WITH KEYNOTE A2. WHICH
REQUIRES CEILING GRID REMOVAL AND REPAIRS
TO BE PERFORMED WITHIN A NEGATIVE
PRESSURE ENCLOSURE, 11 ENCLOSURES, 88
DEFECTS, AND 1,584 SF CEILING TILE
REMOVE NON-ASBESTOS METAL SPLINE CEILING
AND ASBESTOS PIPE INSULATION AND MUDDED
FITTINGS USING GLOVEBAG METHODS WITHIN A
NEGATIVE PRESSURE ENCLOSURE, 100 SF
CEILING AND 25 LF.
ASBESTOS DOOR,FRAME, AND ASSOCIATED
CAULKS. PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION AND/OR MUDDED
FITTINGS PRESENT, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION INTERMITTENTLY
PRESENT THROUGHOUT AND WITHIN WALL
CHASES
REMOVE NON-ASBESTOS SHEET FLOORING AND
UNDERLYING ASBESTOS BLACK MASTIC WITH
MANUAL MEANS IN A NEGATIVE PRESSURE
ENCLOSURE, 100SF
REMNANT ASBESTOS BLACK MASTIC
INTERMITTENTLY ON HVAC DUCT, PROTECT AS
NECESSARY
ON NIGHTS AND WEEKENDS, REMOVE
NON-ASBESTOS WALL PLASTER WITH LBP AND
BLOCKS USING MANUAL MEANS AND ASBESTOS
PIPE INSULATION AND MUDDED FITTINGS USING
GLOVEBAG METHODS IN A NEGATIVE PRESSURE
ENCLOSURE, 150 SF AND 70 LF.
ASBESTOS FLOOR TILE WITH UNDERLYING
ASBESTOS BLACK MASTIC AND/OR
NON-ASBESTOS FLOORING WITH UNDERLYING
BLACK MASTIC PRESENT, PROTECT AS
NECESSARY
REMOVE WINDOW GLASS WITH ASBESTOS
GLAZING AND RESIDUE, USING MANUAL MEANS
WITHIN A NEGATIVE PRESSURE ENCLOSURE.
PROVIDE A TEMPORARY FALL PROTECTION
COVER , 1 SYSTEM.
L1
KEY NOTES
LEAD CONTAINING 4" X 4" WALL TILES PRESENT,
DO NOT DISTURB, PROTECT AS NECESSARY. USE
NON INVASIVE SURFACE MOUNT WALL DATA
JACK SYSTEM WITH ADHESIVE OR SIMILAR. USE
EXISTING SLEEVES THROUGH CERAMIC WALL
TILES WHERE PRESENT.
BEIGE LBP PRESENT ON HANDRAILS, PIPE,
DUCTWORK AND STRUCTURAL STEEL, PROTECT
AS NECESSARY.
LBP DOORS, DOOR FRAMES, STRUCTURAL STEEL,
METAL STAIR SYSTEM COMPONENTS, TYPICAL
THROUGHOUT. PROTECT AS NECESSARY.
LBP WHITE OR YELLOW PAINT ON PLASTER,
CONCRETE OR GLAZED BLOCK, TYPICAL
THROUGHOUT HALLWAY. PROTECT AS
NECESSARY. USE UNPAINTED AREAS ABOVE
CEILING GRID OR NON-INVASIVE MECHANICAL
ATTACHMENTS.
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT
NEGATIVE PRESSURE ENCLOSURE WITH
NEGATIVE AIR MACHINE AND 3-STAGE DECON
N
BLDG 1 - FIRST FLOOR PLAN
A3A3
A3
A3 L2
A3 A3
L1
A5
L3
A10
A9
A3 A3 A3
A3
A3
A3
A1 A1 A1
A1
A4
A7
A1
L4
A3
A6
A3
A3
A3
A3
A3
A5
L3
A3
A6
A3
A3
A3
A3
A3
A10
A6
A3
A6
A6
A3
A6
A6
A3 A6
A3
A6
A3
A6
A10
A10
A3
A6
L2
A3
A6
A3
A6
A3
A6
A6A6
A6
A6
A10
A6A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
L4
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
L3
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A3
A6
A8
A6
A10
A10
A10
L4
A6
A6
A10
L4L2
A2
A3
A4
A5
A6
A7
A8
A9
A10
A11
L2
L3
L4
A1
A9
A11
BID DOCUMENTS
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - SECOND FLOOR -
ENVIRONMENTAL HAZARDS
CD
12 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA-102
No. REVISION DESCRIPTION DATE
N
BLDG 1 - SECOND FLOOR PLAN
A3
L1
A3
L1
A3
A8
A6 L2
A8
A3
A4
A3
A4
A3
A4
A3
A4
A8
A8
A3
A3
A3
A8
A9
A8
L3
A11
A3
A4
L3
A2
L3 A3
L1
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
L3
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
A4
A3
A3
A4
A3
A4
A3
A4
A3
A4A8
A3
A4
A8
A3
A4
A3
A4
A1
L2
A3
A5
A2 A3
A6 L2
L1
A7
A7
A7
A7
A7
A1
A3
A3
A3
A3
A4
A3
A4
A6 L2
A2
L1
A4
A4
A4
A10 A11
A8
A4
A10
A11
A10
A8
A1
A4
A4
L2
A1
REMOVE CEILING TILES AND REPAIR DAMAGED
ASBESTOS PIPE INSULATION, FITTINGS, AND/OR
OPEN JOINTS WITHIN A NEGATIVE PRESSURE
CONTAINMENT. PERFORM WORK IN HALLWAYS
ON NIGHTS AND WEEKENDS. REMOVE
CONTAMINATED CEILING TILES, APPLY TWO
LAYERS OF COVERING LAG CLOTH OVER
DAMAGE/DEFECTS, 4 ENCLOSURES, 8 DEFECTS
WITHIN EACH CONTAINMENT, 400 SF CEILING
TILES
REMOVE ASBESTOS CONTAMINATED CEILING
GRID AND ASBESTOS PIPE INSULATION AND
MUDDED FITTINGS USING GLOVEBAG METHODS
IN A NEGATIVE PRESSURE ENCLOSURE, 3
ENCLOSURES, 432 SF CEILING TILES, 100LF
ASBESTOS PIPE INSULATION AND/OR MUDDED
FITTINGS PRESENT, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION INTERMITTENTLY
PRESENT THROUGHOUT AND WITHIN WALL
CHASES
PRIOR TO WORK IN AREA, INSPECT FOR
ASBESTOS PIPE INSULATION DAMAGE.
INSPECTION TO BE PERFORMED BY AN
APPROVED LICENSED ASBEST0S INSPECTOR
WITH EMPHASIS OF AREAS ABOVE CEILING GRID.
WHERE ASBESTOS INSULATION DAMAGE OR
CONTAMINATION IS VERIFIED, PERFORM WORK IN
ACCORDANCE WITH KEYNOTE A1 WHICH
REQUIRES CONTAMINATED CEILING TILE
REMOVAL, PRE-CLEANING, AND REPAIRS TO BE
PERFORMED WITHIN A NEGATIVE PRESSURE
ENCLOSURE, 9 ENCLOSURES, 72 DEFECTS AND
1,296 SF CEILING TILE
REMOVE NON-ASBESTOS FLOOR TILE AND
UNDERLYING ASBESTOS FLOOR TILE WITH
UNDERLYING ASBESTOS BLACK MASTIC USING
MANUAL MEANS IN A NEGATIVE PRESSURE
CONTAINMENT, 100 SF, 1 ENCLOSURE.
ASBESTOS DOOR,FRAME, AND ASSOCIATED
CAULKS. PROTECT AS NECESSARY.
ON NIGHTS AND WEEKENDS, REMOVE CEILING
TILES AND ASBESTOS PIPE INSULATION AND
MUDDED FITTINGS USING GLOVEBAG METHODS
IN A NEGATIVE PRESSURE ENCLOSURE, 360 SF
CEILING TILES AND 200 LF.
ASBESTOS FLOOR TILE WITH UNDERLYING
ASBESTOS BLACK MASTIC AND/OR
NON-ASBESTOS FLOORING WITH UNDERLYING
BLACK MASTIC PRESENT, PROTECT AS
NECESSARY
ASBESTOS BLACK MASTIC WITHIN WALL CHASE
AND WITHIN EXTERIOR WALL, DO NOT DISTURB
PROTECT AS NECESSARY.
REMNANT ASBESTOS BLACK MASTIC
INTERMITTENTLY ON HVAC DUCT, PROTECT AS
NECESSARY
COORDINATE WITH GENERAL CONTRACTOR,
WHERE NECESSARY REMOVE NON-ASBESTOS
WALL PLASTER AND BLOCKS WITH LBP USING
MANUAL MEANS. REMOVE ASBESTOS PIPE
INSULATION AND MUDDED FITTINGS USING
GLOVEBAG METHODS IN A NEGATIVE PRESSURE
ENCLOSURE, 150 SF BLOCK/PLASTER AND 70 LF
INSULATION.
REMOVE WINDOW GLASS WITH ASBESTOS
GLAZING AND RESIDUE, USING MANUAL MEANS
WITHIN A NEGATIVE PRESSURE ENCLOSURE.
PROVIDE A TEMPORARY FALL PROTECTION
COVER , 1 SYSTEM.
L1
LEAD CONTAINING 4" X 4" WALL TILES PRESENT,
DO NOT DISTURB, PROTECT AS NECESSARY. USE
NON INVASIVE SURFACE MOUNT WALL DATA
JACK SYSTEM WITH ADHESIVE OR SIMILAR. USE
EXISTING SLEEVES THROUGH CERAMIC WALL
TILES WHERE PRESENT.
LBP DOORS, DOOR FRAMES, STRUCTURAL STEEL,
METAL STAIR SYSTEM COMPONENTS, TYPICAL
THROUGHOUT. PROTECT AS NECESSARY.
DRYWALL WALLS WITH LEAD SHIELDING.
PROVIDE ROUGH IN THROUGH LEAD LINED
DRYWALL FOR FLUSH MOUNTED JACK SYSTEM IN
ACCORDANCE WITH PROJECT NEA FOR RRP.
MINIMUM 1 SYSTEM EACH ROOM, 8 TOTAL JACKS,
3 HALLWAY TO ROOM PENETRATIONS. REUSE
EXISTING JACK SYSTEM WITHOUT DISTURBING
LEAD MATERIALS.
REMOVE DOOR AND DOOR FRAME WITH LBP
WITHIN A NEGATIVE PRESSURE CONTAINMENT, 1
DOOR AND ASSOCIATED FRAME
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT
NEGATIVE PRESSURE ENCLOSURE WITH
NEGATIVE AIR MACHINE AND 3-STAGE DECON
KEY NOTES
A2
A3
A4
A1
A12
A9
L4
A5
A5
A6
A7
A8
A9
A10
A11
A12
L2
L3
L4
BID DOCUMENTS
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - THIRD FLOOR -
ENVIRONMENTAL HAZARDS
CD
13 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA103
No. REVISION DESCRIPTION DATE
N
BLDG 1 - THIRD FLOOR PLAN
A5
A5
A5 A5 A5
A5 A5 A5
A5
A11
L2
A9
A5
L1
A5
A2
A5
A3
A5
A3
A5
A3
A6
L2
A5
A3
A5
A3
A5
A3
A5
A3
A5
A3
A1
A5
A5
A3
A5
A3
A5
A3
A5
A3
A5
A3
A5
A3
A5
A3
A5
A3
L3
A5
A3
L3
L1
A1
A5
A3
L3
A5
A3
L3
A5
A3
A5
A3
L1
A5
L1
A9
A1
A1
A1
A4
A8
A8
A3
A5
A3
A5
A3
A5
A8
A8 A8
A8
A8
A8
A8
A8
A8
A8 A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A8
A5
A5
A5
A6
A5
A7
A5
L1
L1
A6
A6
A6
A10
L2
A3
A3
A5
A7
A3
L3
L1
LEAD CONTAINING 4" X 4" WALL TILES PRESENT,
DO NOT DISTURB, PROTECT AS NECESSARY. USE
NON INVASIVE SURFACE MOUNT WALL DATA
JACK SYSTEM WITH ADHESIVE OR SIMILAR. USE
EXISTING SLEEVES THROUGH CERAMIC WALL
TILES WHERE PRESENT.
LBP DOORS, DOOR FRAMES, STRUCTURAL STEEL,
METAL STAIR SYSTEM COMPONENTS, TYPICAL
THROUGHOUT. PROTECT AS NECESSARY.
REMOVE DOOR AND DOOR FRAME WITH LBP
WITHIN A NEGATIVE PRESSURE CONTAINMENT, 2
DOORS AND ASSOCIATED FRAMES
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT
NEGATIVE PRESSURE ENCLOSURE WITH
NEGATIVE AIR MACHINE AND 3-STAGE DECON
A1
REMOVE CEILING TILES WITH PRESUMED
ASBESTOS CONTAMINATION AND REPAIR
DAMAGED ASBESTOS PIPE INSULATION, FITTINGS,
AND/OR OPEN JOINTS WITHIN A NEGATIVE
PRESSURE CONTAINMENT. PERFORM WORK IN
HALLWAYS ON NIGHTS AND WEEKENDS. REMOVE
CONTAMINATED CEILING TILES, PRECLEAN, AND
APPLY TWO LAYERS OF COVERING LAG CLOTH
OVER DAMAGE/DEFECTS, 4 ENCLOSURES, 8
DEFECTS WITHIN EACH ENCLOSURE, 650 SF
CEILING TILES
REMOVE ASBESTOS CEILING PLASTER AND
ASBESTOS PIPE INSULATION AND MUDDED
FITTINGS USING MANUAL MEANS AND GLOVEBAG
METHODS WITHIN A NEGATIVE PRESSURE
ENCLOSURE, 100SF PLASTER AND 20 LF PIPE
INSULATION
PRIOR TO WORK IN AREA, INSPECT FOR
ASBESTOS PIPE INSULATION DAMAGE.
INSPECTION TO BE PERFORMED BY AN
APPROVED LICENSED ASBEST0S INSPECTOR
WITH EMPHASIS OF AREAS ABOVE CEILING GRID.
WHERE ASBESTOS INSULATION DAMAGE OR
CONTAMINATION IS VERIFIED, PERFORM WORK IN
ACCORDANCE WITH KEYNOTE A1 WHICH
REQUIRES CONTAMINATED CEILING TILE
REMOVAL, PRE-CLEANING, AND REPAIRS TO BE
PERFORMED WITHIN A NEGATIVE PRESSURE
ENCLOSURE, 8 ENCLOSURES, 64 DEFECTS AND
1,152 SF CEILING TILE
REMOVE NON-ASBESTOS FLOOR TILE AND
UNDERLYING ASBESTOS FLOOR TILE WITH
ASBESTOS BLACK MASTIC USING MANUAL MEANS
IN A NEGATIVE PRESSURE ENCLOSURE, 120 SF, 2
CONTAINMENTS
ASBESTOS PIPE INSULATION AND/OR MUDDED
FITTINGS PRESENT, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION INTERMITTENTLY
PRESENT THROUGHOUT AND WITHIN WALL
CHASES
ASBESTOS FLOOR TILE OR TERRAZZO FLOORING
WITH UNDERLYING ASBESTOS BLACK MASTIC
WHERE TILE IS PRESENT, PROTECT AS
NECESSARY.
ASBESTOS GREEN MARBLE WALL COVERING
AND UNDERLYING MASTIC. DO NOT DISTURB,
PROTECT AS NECESSARY. USE NON INVASIVE
SURFACE MOUNT WALL DATA JACK SYSTEM WITH
ADHESIVE OR SIMILAR. USE EXISTING SLEEVES
THROUGH MARBELIZED CORRIDOR WALLS AND
WITHIN ROOMS..
ASBESTOS BLACK TAR (PACM) INTERMITTENTLY
PRESENT IN EXTERIOR WALL POCKET , PROTECT
AS NECESSARY
REMNANT ASBESTOS BLACK MASTIC
INTERMITTENTLY ON HVAC DUCT, PROTECT AS
NECESSARY
ASBESTOS DOOR FRAME, AND ASSOCIATED
CAULKS. PROTECT AS NECESSARY.
KEY NOTES
L2
L3
A2
A3
A4
A5
A6
A7
A8
A9
A10
BID DOCUMENTS
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - FOURTH FLOOR -
ENVIRONMENTAL HAZARDS
CD
14 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA104
No. REVISION DESCRIPTION DATE
N
BLDG 1 - FOURTH FLOOR PLAN
A2
A3
A2 A3
A2 A3 A2 A4
L2
A3
A4
A5
A4
A3
L2
A2
A4 A3
A4
A3
A3
A5
A4
A2
A3
A5
A4
A4 A5
A5
A2 A4 A5
A4
A5
A4
A5
A4
A5
A4
A5
A4
A5
A4
A5
A4
A5
A4
A5
A4
A5
A3
A4 A5
A2 A3
A4 A5
A2 A3
A4 A5
A2 A4
A5
A2 A4
A5
A2 A4
A5
A2 A4
A5
A2 A4
A5
A2 A4
A5
A2 A4
A5
A2 A4
A5
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4 A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A5 A4
A2 A3
A5 A4
A2 A3
A5 A4
A2 A3
A5 A4
A2 A3
A5 A4
A2 A3
A4
A4
A3
L2
A6
A1
ASBESTOS KEY NOTES
REMOVE NON-ASBESTOS FLOOR TILE AND
UNDERLYING FLOOR LEVELER AND ASBESTOS
BLACK MASTIC USING MANUAL MEANS IN A
NEGATIVE PRESSURE ENCLOSURE, 160 SF, 1
CONTAINMENT
PRIOR TO WORK IN AREA, INSPECT FOR
ASBESTOS PIPE INSULATION DAMAGE.
INSPECTION TO BE PERFORMED BY AN
APPROVED LICENSED ASBEST0S INSPECTOR
WITH EMPHASIS OF AREAS ABOVE CEILING GRID.
WHERE ASBESTOS INSULATION DAMAGE OR
CONTAMINATION IS VERIFIED, REMOVE
ASBESTOS CONTAMINATED CEILING TILES AND
REPAIR DAMAGED ASBESTOS PIPE INSULATION,
FITTINGS, AND/OR OPEN JOINTS WITHIN A
NEGATIVE PRESSURE CONTAINMENT. PERFORM
WORK IN HALLWAYS ON NIGHTS AND WEEKENDS.
REMOVE CONTAMINATED CEILING TILES, APPLY
TWO LAYERS OF COVERING LAG CLOTH OVER
DAMAGE/DEFECTS, 1 ENCLOSURE, 8 DEFECTS
AND 144 SF CEILING TILE
ASBESTOS PIPE INSULATION AND/OR MUDDED
FITTINGS PRESENT WITHIN CHASES, PROTECT AS
NECESSARY.
NON-ASBESTOS FLOOR COVERING WITH
POTENTIAL FOR UNDERLYING ASBESTOS BLACK
MASTIC, PROTECT AS NECESSARY
ASBESTOS BLACK TAR (PACM) WITHIN EXTERIOR
WALL POCKET AND AT INTERMITTENT LOCATIONS
ABOVE CEILING GRID, PROTECT AS NECESSARY
ASBESTOS ROOF SYSTEM, DO NOT DISTURB AND
PROTECT AS NECESSARY
L1
LEAD KEY NOTES AND VISUAL GUIDE
REMOVE DOOR AND DOOR FRAME WITH LBP
WITHIN A NEGATIVE PRESSURE CONTAINMENT, 2
DOORS AND ASSOCIATED FRAMES.
LBP DOORS, DOOR FRAMES, STRUCTURAL STEEL,
METAL STAIR SYSTEM COMPONENTS, TYPICAL
THROUGHOUT. PROTECT AS NECESSARY.
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT
NEGATIVE PRESSURE ENCLOSURE WITH
NEGATIVE AIR MACHINE AND 3-STAGE DECON
GENERAL NOTES
ALL ACM ABATEMENT SHALL BE PERFORMED BY
TRAINED/LICENSED ASBESTOS ABATEMENT
CONTRACTOR WITHIN A FULL CONTAINMENT
UNDER NEGATIVE PRESSURE (NPE) UNLESS
OTHERWISE SHOWN.
BLACK MASTIC IS POTENTIALLY PRESENT
UNDERLYING NEWER NON-ACM FLOORING
THROUGHOUT BUILDING 1, FLOOR 4.
GENERALLY, 4"X4" CERAMIC WALL TILES ON THIS
FLOOR WILL NOT CONTAIN LEAD. DO NOT IMPACT
THESE TILES AND LOCATIONS ARE GENERALLY
NOT SHOWN. WINDOW ELEMENTS HANDRAILS,
STRUCTURAL STEEL, AND METAL STAIR SYSTEMS
GENERALLY CONTAIN LEAD AND ARE NOT
SHOWN, DO NOT DISTURB.
OTHER ACM MATERIALS ARE PRESENT AND
GENERALLY NOT SHOWN FOR CLARITY
PURPOSES AND/OR NOT THOUGHT TO BE
IMPACTED BY PROJECT INCLUDE, TERRAZZO
FLOORS, UNDER-SINK COATINGS, FLOOR TILES
UNDERLYING OTHER NON-ACM FLOORING, BLACK
MASTIC UNDERLYING NON-ACM FLOORING,
CAULK AT DOOR FRAMES, ELEVATOR AND
DUMBWAITER DOORS, ROOF SYSTEM/TARS,
BLACK TAR ON EXTERIOR WALL OR CHASES,
BLACK TAR ON HVAC DUCTS UNDERLING
INSULATION, WINDOW ASSEMBLIES AND BLACK
TAR OR TRANSITE WITHIN HISTORIC HEAT
CONVECTOR WALL POCKETS.
A2
L2
A1 L1
A2
A2
A2
A3
A4
A5
A6
A2
A2
A2 A4 A5
A2 A4 A5
BID DOCUMENTS
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 1 - FIFTH FLOOR -
ENVIRONMENTAL HAZARDS
CD
15 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA105
No. REVISION DESCRIPTION DATE
L1
REMOVE DOOR AND DOOR FRAME WITH LBP
WITHIN A NEGATIVE PRESSURE CONTAINMENT, 3
DOORS AND ASSOCIATED FRAMES
LBP DOORS, DOOR FRAMES, STRUCTURAL STEEL,
METAL STAIR SYSTEM COMPONENTS, TYPICAL
THROUGHOUT. PROTECT AS NECESSARY.
DRYWALL WALLS WITH LEAD SHIELDING.
PROVIDE ROUGH IN THROUGH LEAD LINED
DRYWALL FOR FLUSH MOUNTED JACK SYSTEM IN
ACCORDANCE WITH PROJECT NEA FOR RRP.
MINIMUM 1 SYSTEM EACH ROOM, 23 TOTAL
JACKS, 10 HALLWAY TO ROOM PENETRATIONS.
REUSE EXISTING JACK SYSTEM WITHOUT
DISTURBING LEAD MATERIALS.
LEAD CONTAINING 4" X 4" WALL TILES PRESENT,
DO NOT DAMAGE, PROTECT AS NECESSARY. USE
EXISTING SURFACE MOUNT SYSTEM AS
NECESSARY.
YELLOW, GREEN AND WHITE GLAZED BLOCKS
ARE LEAD CONTAINING, PROTECT AS
NECESSARY.
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT
NEGATIVE PRESSURE ENCLOSURE WITH
NEGATIVE AIR MACHINE AND 3-STAGE DECON
ASBESTOS FLOOR TILE AND/OR ASBESTOS
BLACK MASTIC PRESENT & NEGATIVE PRESSURE
ENCLOSURE WITH NEGATIVE AIR MACHINE AND
3-STAGE DECON
A1
REMOVE NON-ASBESTOS SHEET FLOORING AND
UNDERLYING ASBESTOS FLOOR TILE WITH
ASBESTOS BLACK MASTIC USING MANUAL MEANS
IN A NEGATIVE PRESSURE ENCLOSURE, 140 SF, 3
ENCLOSURES
REMOVE CEILING TILES AND REPAIR DAMAGED
ASBESTOS PIPE INSULATION, FITTINGS, AND/OR
OPEN JOINTS WITHIN A NEGATIVE PRESSURE
CONTAINMENT. PERFORM WORK IN HALLWAYS
ON NIGHTS AND WEEKENDS. REMOVE
CONTAMINATED CEILING TILES, APPLY TWO
LAYERS OF COVERING LAG CLOTH OVER
DAMAGE/DEFECTS, 3 CONTAINMENTS, 8
DEFECTS WITHIN EACH ENCLOSURE, 560 SF
CEILING TILES
ASBESTOS PIPE INSULATION AND/OR MUDDED
FITTINGS PRESENT, PROTECT AS NECESSARY.
ASBESTOS PIPE INSULATION INTERMITTENTLY
PRESENT THROUGHOUT AND WITHIN WALL
CHASES
ASBESTOS FLOOR TILE OR TERRAZZO FLOORING
WITH UNDERLYING ASBESTOS BLACK MASTIC
WHERE TILE IS PRESENT, PROTECT AS
NECESSARY.
ASBESTOS DOOR,FRAME, AND ASSOCIATED
CAULKS. PROTECT AS NECESSARY.
ASBESTOS BLACK TAR (PACM), BLACK OR
PAINTED SILVER, ON EXTERIOR WALL AND/OR
CEILING ABOVE CEILING GRID, PROTECT AS
NECESSARY
ASBESTOS PIPE INSULATION IN PLASTER CHASE,
PROTECT AS NECESSARY
ASBESTOS ROOF SYSTEM, DO NOT DISTURB AND
PROTECT AS NECESSARY
REMOVE ASBESTOS PIPE INSULATION AND
MUDDED FITTINGS USING GLOVEBAG METHODS
WITHIN A NEGATIVE PRESSURE ENCLOSURE,
20LF.
PRIOR TO WORK IN AREA, INSPECT FOR
ASBESTOS PIPE INSULATION DAMAGE.
INSPECTION TO BE PERFORMED BY AN
APPROVED LICENSED ASBEST0S INSPECTOR
WITH EMPHASIS OF AREAS ABOVE CEILING GRID.
WHERE ASBESTOS INSULATION DAMAGE OR
CONTAMINATION IS VERIFIED, PERFORM WORK IN
ACCORDANCE WITH KEYNOTE A2 WHICH
REQUIRES CONTAMINATED CEILING TILE
REMOVAL, PRE-CLEANING, AND REPAIRS TO BE
PERFORMED WITHIN A NEGATIVE PRESSURE
ENCLOSURE, 8 ENCLOSURES, 64 DEFECTS AND
1,152 SF CEILING TILE
COORDINATE LOCATIONS AND REMOVE
ASBESTOS TAR ON CONCRETE CEILING USING
CHEMICAL REMOVAL AND MANUAL MEANS WITHIN
A NEGATIVE PRESSURE CONTAINMENT. REFER
TO CABLE SUPPORT DETAIL ON DRAWING T-503, 1
SF REMOVAL EACH AT 15 ATTACHMENT
LOCATIONS.
REMNANT ASBESTOS BLACK MASTIC
INTERMITTENTLY ON HVAC DUCT, PROTECT AS
NECESSARY
A5
L2
A5
L2
L2
L3
L3
L3
L3
L4
A4
L4
L3
A7
L1
L3 L3
A4
A1
A7
L1
A6
L2
A4 A4
A4A4
A3
A4
A6
A3
A6
A7
A4
A4
A4 A4
A6
A2
L2
L3
L3
L3
L1
A7
L1
A7
A7
A4 A4
L1 L1
L1
L1
A6
A2
A2
A2
A2
A4
A6
A3
A6
L4
A7
A3
A4
A6
A8
A10
A10
A10
A10
A10
L4
A10
L3
A6
A10 A10 A10 A10
A10
A10
A10
A3
A8
A5
L2
A10
A10
A10
A10
A3
A10
N
BLDG 1 - FIFTH FLOOR PLAN
KEY NOTES
A2
A3
A4
A5
A6
A7
A8
A9
A10
L2
L3
L4
L5
L1
A1
A4
A11
A12
A11
A12 L2 L5
BID DOCUMENTS
N
BLDG 1 - FIFTH FLOOR PLAN DETAIL - 528
A9
A1
A6
A7
L1
A7
AutoCAD SHX Text 1/16" = 1'-0"
NOT TO SCALE
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 2 - FIRST FLOOR -
ENVIRONMENTAL HAZARDS
CD
16 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA201
No. REVISION DESCRIPTION DATE
N
BLDG 2 - FIRST FLOOR PLAN
A3
L1
A3
L1
A3
L1
A3
L1
L2
L1
A4
L1
L1
L2
A4
L2
L2
L2
L2
L2
A4
L1
L2
L2
A2
A1
A1
KEY NOTES
ASBESTOS COMPONENTS WITHIN FUME HOOD,
DO NOT PUNCTURE OR ABRADE, PROTECT AS
NECESSARY.
ASBESTOS SINK UNDERCOATING, PROTECT AS
NECESSARY
ASBESTOS WINDOW COMPONENTS (PACM),
PROTECT AS NECESSARY
ASBESTOS FIRE DOORS AND FRAMES (PACM),
PROTECT AS NECESSARY
LBP PRESENT ON DOOR AND WINDOW SYSTEM
COMPONENTS THROUGHOUT, PROTECT AS
NECESSARY
LBP PRESENT ON STRUCTURAL STEEL, STAIR
RAILS, AND STRINGERS AND/OR PIPES
THROUGHOUT, PROTECT AS NECESSARY
A2
A3
A4
L1
L2
GENERAL NOTES
CONTRACTOR AND IT'S EMPLOYEES ARE TO BE
LICENSED TO ENGAGE IN ASBESTOS AND LEAD RELATED
PROJECT WORK.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN
AND DUCT OPENINGS COVERED WITH CRITICAL
BARRIERS THROUGHOUT ABATEMENT. SCHEDULE
SHUTDOWNS WITH THE OWNER TO ACCOMMODATE
FACILITY AND CONSTRUCTION REQUIREMENTS.
ALL PERSONS WITHIN AN NPE SHALL DON, AT MINIMUM,
HALF FACE AIR PURIFYING RESPIRATORS WITH P100
FILTERS, DISPOSABLE DUST SUITS (WITH BOOT AND
HEAD COVERS) AND GLOVES. RESPIRATORY
PROTECTION MAY REQUIRE USE OF POWERED AIR
PURIFYING RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES
SHALL BE PREPARED IN ACCORDANCE WITH THE
FOLLOWING:A) ALL FLOORS,AND WALLS SHALL BE
ISOLATED USING 2-LAYERS OF 6-MIL POLY SHEETING; B)
OSHA ASBESTOS SIGNAGE AT ENTRANCE TO
REGULATED AREAS; C)SINGLE-POINT OF ENTRY WITH
3-STAGE WET DECONTAMINATION STATION TO ALLOW
WORKERS TO REMOVE PPE, WASH AND VACUUM
THEMSELVES OFF PRIOR TO EXITING THE REGULATED
WORK AREA; D) MAINTAINED UNDER NEGATIVE
PRESSURE (-0.02 IN WG OR BETTER) USING HEPA
FILTERED AIR MACHINES WITH EXHAUST ROUTED TO
OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR;
F) CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS TO
CHANGE INTO STREET CLOTHES (OPAQUE POLY
REQUIRED AS NEEDED FOR PRIVACY); G) RENEWABLE
ADHESIVE MATS IMMEDIATELY OUTSIDE OF REGULATED
WORK AREA TO ENSURE FOOT TRAFFIC DOES NOT
SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING
CONTROLS: A) HEPA FILTERED VACUUM FOR
CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL
REMOVAL MEANS/TOOLS ARE ALLOWED TO DISTURB
ACM (MECHANICAL TOOLS PROHIBITED FOR ACM
REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE
HEPA VACUUMING & WET WIPING METHODS. REGULATED
AREAS ARE TO PASS A SUCCESSFUL VISUAL INSPECTION
BY THE VPIH PRIOR TO COLLECTION OF CLEARANCE
SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING,
VISUAL INSPECTIONS AND FINAL AIR CLEARANCE
SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE
EXPOSURE MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE
COLLECTED, CONTAINERIZED, LABELED,
CHARACTERIZED AND DISPOSED IN ACCORDANCE WITH
SPECIFICATION 02.82.11
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL
BE WET WIPED PRIOR TO LEAVING REGULATED WORK
AREA.
WHERE THE COMBINED AREA OF THE NPE WORK
CHAMBER, DECONTAMINATION AND LOADOUT
CHAMBERS DO NOT FIT WITHIN A ROOM, THE
DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2
WIDTH OF THE HALLWAY AS REQUIRED TO ALLOW
PASSAGE IN CORRIDOR.
BID DCOUMENTS
r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 2 - SECOND FLOOR -
ENVIRONMENTAL HAZARDS
CD
17 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA202
No. REVISION DESCRIPTION DATE
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A3
L1
A4
L1
A3
L1
A4
L1
A3
L1
L2
A1
A1
A5
L2
L2
L2
L2
L1
L2
L2
L2
L2
L2
L3
L3
L2
L2
L2
L3
L1
L3 A2
L1
L1
N
BLDG 2 - SECOND FLOOR PLAN
A1
KEY NOTES
ASBESTOS PIPE INSULATION AND/OR FITTINGS
ARE PRESENT ABOVE PLASTER CEILINGS AND/OR
WITHIN WET WALLS AND CEILING AREAS,
PROTECT AS NECESSARY
ASBESTOS FLOOR TILE WITH UNDERLYING
ASBESTOS BLACK MASTIC UNDER CARPET,
PROTECT AS NECESSARY.
ASBESTOS WINDOW COMPONENTS (PACM),
PROTECT AS NECESSARY
ASBESTOS FIRE DOORS AND FRAMES (PACM),
PROTECT AS NECESSARY
ASBESTOS ROOF SYSTEM AND ASSOCIATED
COMPONENTS (PACM), DO NOT PENETRATE AND
PROTECT AS NECESSARY.
LBP PRESENT ON DOOR AND WINDOW SYSTEM
COMPONENTS THROUGHOUT, PROTECT AS
NECESSARY
LBP PRESENT ON STRUCTURAL STEEL, STAIR
RAILS, AND STRINGERS AND PIPES (FP & DP)
THROUGHOUT, PROTECT AS NECESSARY
LBP PRESENT ON BLOCK WALL, PROTECT AS
NECESSARY
REMOVE LBP IN SPOT LOCATIONS USING
CHEMICAL STRIPPER IN ACCORDANCE WITH
PROJECT NEA BY RRP, 5 WALL JACK LOCATIONS,
2S F EACH. COORDINATE LOCATIONS WITH
GENERAL CONTRACTOR.
A2
A3
A4
A5
L1
L2
L3
GENERAL NOTES
CONTRACTOR AND IT'S EMPLOYEES ARE TO BE
LICENSED TO ENGAGE IN ASBESTOS AND LEAD RELATED
PROJECT WORK.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN
AND DUCT OPENINGS COVERED WITH CRITICAL
BARRIERS THROUGHOUT ABATEMENT. SCHEDULE
SHUTDOWNS WITH THE OWNER TO ACCOMMODATE
FACILITY AND CONSTRUCTION REQUIREMENTS.
ALL PERSONS WITHIN AN NPE SHALL DON, AT MINIMUM,
HALF FACE AIR PURIFYING RESPIRATORS WITH P100
FILTERS, DISPOSABLE DUST SUITS (WITH BOOT AND
HEAD COVERS) AND GLOVES. RESPIRATORY
PROTECTION MAY REQUIRE USE OF POWERED AIR
PURIFYING RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES
SHALL BE PREPARED IN ACCORDANCE WITH THE
FOLLOWING:A) ALL FLOORS,AND WALLS SHALL BE
ISOLATED USING 2-LAYERS OF 6-MIL POLY SHEETING; B)
OSHA ASBESTOS SIGNAGE AT ENTRANCE TO
REGULATED AREAS; C)SINGLE-POINT OF ENTRY WITH
3-STAGE WET DECONTAMINATION STATION TO ALLOW
WORKERS TO REMOVE PPE, WASH AND VACUUM
THEMSELVES OFF PRIOR TO EXITING THE REGULATED
WORK AREA; D) MAINTAINED UNDER NEGATIVE
PRESSURE (-0.02 IN WG OR BETTER) USING HEPA
FILTERED AIR MACHINES WITH EXHAUST ROUTED TO
OUTDOORS; E) MINIMUM OF 4 AIR CHANGES PER HOUR;
F) CLEAN/CHANGE ROOM SUFFICIENT FOR WORKERS TO
CHANGE INTO STREET CLOTHES (OPAQUE POLY
REQUIRED AS NEEDED FOR PRIVACY); G) RENEWABLE
ADHESIVE MATS IMMEDIATELY OUTSIDE OF REGULATED
WORK AREA TO ENSURE FOOT TRAFFIC DOES NOT
SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING
CONTROLS: A) HEPA FILTERED VACUUM FOR
CONTINUOUS AND FINAL CLEANUP; B) ONLY MANUAL
REMOVAL MEANS/TOOLS ARE ALLOWED TO DISTURB
ACM (MECHANICAL TOOLS PROHIBITED FOR ACM
REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE
HEPA VACUUMING & WET WIPING METHODS. REGULATED
AREAS ARE TO PASS A SUCCESSFUL VISUAL INSPECTION
BY THE VPIH PRIOR TO COLLECTION OF CLEARANCE
SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING,
VISUAL INSPECTIONS AND FINAL AIR CLEARANCE
SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE
EXPOSURE MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE
COLLECTED, CONTAINERIZED, LABELED,
CHARACTERIZED AND DISPOSED IN ACCORDANCE WITH
SPECIFICATION 02.82.11
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL
BE WET WIPED PRIOR TO LEAVING REGULATED WORK
AREA.
WHERE THE COMBINED AREA OF THE NPE WORK
CHAMBER, DECONTAMINATION AND LOADOUT
CHAMBERS DO NOT FIT WITHIN A ROOM, THE
DECON/LOADOUT CONFIGURATION MAY EXTEND INTO 1/2
WIDTH OF THE HALLWAY AS REQUIRED TO ALLOW
PASSAGE IN CORRIDOR.
BID DOCUMENTS
L4
L4
L4
L4
L4 r e e i n c h e s o n e f o o t o n e a n d o n e h a l f i n c h e s o n e f o o t o n e i n c h o n e f o o t t h r e e q u a r t e r s i n c h o n e f o o t o n e h a l f i n c h o n e f o o t t h r e e e i g h t h s i n c h o n e f o o t o n e q u a r t e r i n c h o n e f o o t o n e e i g h t h i n c h o n e f o o t
A
B
C
D
E
F
Veterans
Health
Administration
VA FORM 08-6231
Drawing Title Project Title
Location
Date Checked Drawn
Project Number
CONSULTANTS:
Drawing # OF
VA Health Care System Approval:
ARCHITECT:
SPUR DESIGN, LLC
312 SW 25TH STREET
Oklahoma City, OK 73109
(405) 842-6100
ARCH REG. NO. AR12100034 EXP. 12/31/2021
MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022
ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022
CIVIL ENGINEER
OLSSON
550 ST LOUIS ST,
SPRINGFIELD, MO 65806
(417) 885-1736
MECH / ELEC / PLUMB / TECH ENGINEER
SPUR DESIGN
11020 KING STREET, SUITE 350
OVERLAND PARK, KS 66210
(913) 369-7200
FIRE PROTECTION ENGINEER
POOLE FIRE PROTECTION, INC.
19910 WEST 161ST STREET
OLATHE, KANSAS 66062
(913) 829-8690
FULLY SPRINKLERED
INDUSTRIAL HYGENIST
RIVERFRONT SAFETY & HEALTH
1139 OLIVE ST, SUITE 300
ST. LOUIS, MO 63101
(713) 864-2900
HEALTHCARE PLANNER
ASPEN COMMUNICATIONS, LLC
7 KIJI-DAVA CIRCLE, SUITE A
PRESCOTT, AZ 85712
(928) 774-0992
PHYSCIAL SECURITY
FORCE PROTECT
3210 GULF BLVD, UNIT 304
BELLEAIR BEACH, FL 33786
(502) 836-4232
1 2 3 4 5 6 7 8 9
1 2 3 4 5 6 7 8 9
A
B
C
D
E
F
STAMP:
Drawing Number
Building Number
P
M
BUILDING 3 - BASEMENT -
ENVIRONMENTAL HAZARDS
CD
18 119
JR
EHRM INFRASTRUCTURE
UPGRADES FORT WAYNE,
INDIANA
11/12/2021
610A4-21-701
VANIHCS
2121 LAKE AVE
FORT WAYNE, IN 46805
HA300
No. REVISION DESCRIPTION DATE
UP
N
BLDG 3 - BASEMENT PLAN
A1
A2
A1
A1
A2
A2
A2
A2
L1
L1
GENERAL NOTES
CONTRACTOR AND IT'S EMPLOYEES ARE TO BE LICENSED
TO ENGAGE IN ASBESTOS AND LEAD RELATED PROJECT
WORK.
WITHIN AN NPE, HVAC AIR FLOW SHALL BE SHUTDOWN AND
DUCT OPENINGS COVERED WITH CRITICAL BARRIERS
THROUGHOUT ABATEMENT. SCHEDULE SHUTDOWNS WITH
THE OWNER TO ACCOMMODATE FACILITY AND
CONSTRUCTION REQUIREMENTS.
ALL PERSONS WITHIN AN NPE SHALL DON, AT MINIMUM,
HALF FACE AIR PURIFYING RESPIRATORS WITH P100
FILTERS, DISPOSABLE DUST SUITS (WITH BOOT AND HEAD
COVERS) AND GLOVES. RESPIRATORY PROTECTION MAY
REQUIRE USE OF POWERED AIR PURIFYING RESPIRATORS.
REGULATED AREA NEGATIVE PRESSURE ENCLOSURES
SHALL BE PREPARED IN ACCORDANCE WITH THE
FOLLOWING:A) ALL FLOORS,AND WALLS SHALL BE
ISOLATED USING 2-LAYERS OF 6-MIL POLY SHEETING; B)
OSHA ASBESTOS SIGNAGE AT ENTRANCE TO REGULATED
AREAS; C)SINGLE-POINT OF ENTRY WITH 3-STAGE WET
DECONTAMINATION STATION TO ALLOW WORKERS TO
REMOVE PPE, WASH AND VACUUM THEMSELVES OFF
PRIOR TO EXITING THE REGULATED WORK AREA; D)
MAINTAINED UNDER NEGATIVE PRESSURE (-0.02 IN WG OR
BETTER) USING HEPA FILTERED AIR MACHINES WITH
EXHAUST ROUTED TO OUTDOORS; E) MINIMUM OF 4 AIR
CHANGES PER HOUR; F) CLEAN/CHANGE ROOM SUFFICIENT
FOR WORKERS TO CHANGE INTO STREET CLOTHES
(OPAQUE POLY REQUIRED AS NEEDED FOR PRIVACY); G)
RENEWABLE ADHESIVE MATS IMMEDIATELY OUTSIDE OF
REGULATED WORK AREA TO ENSURE FOOT TRAFFIC DOES
NOT SPREAD DUST/DEBRIS TO OTHER AREAS OF FACILITY.
PERFORM ABATEMENT USING THE FOLLOWING CONTROLS:
A) HEPA FILTERED VACUUM FOR CONTINUOUS AND FINAL
CLEANUP; B) ONLY MANUAL REMOVAL MEANS/TOOLS ARE
ALLOWED TO DISTURB ACM (MECHANICAL TOOLS
PROHIBITED FOR ACM REMOVAL).
CLEANING OF REGULATED WORK AREAS IS TO INCLUDE
HEPA VACUUMING & WET WIPING METHODS. REGULATED
AREAS ARE TO PASS A SUCCESSFUL VISUAL INSPECTION
BY THE VPIH PRIOR TO COLLECTION OF CLEARANCE
SAMPLES.
VPIH WILL PERFORM PERIMETER AIR MONITORING, VISUAL
INSPECTIONS AND FINAL AIR CLEARANCE SAMPLING.
CONTRACTOR TO PERFORM OSHA EMPLOYEE EXPOSURE
MONITORING.
WASTE PRODUCED DURING REMEDIATION SHALL BE
COLLECTED, CONTAINERIZED, LABELED, CHARACTERIZED
AND DISPOSED IN ACCORDANCE WITH SPECIFICATION
02.82.11
WASTE CONTAINERS, TOOLS, EQUIPMENT, ETC. SHALL BE
WET WIPED PRIOR TO LEAVING REGULATED WORK AREA.
WHERE THE COMBINED AREA OF THE NPE WORK
CHAMBER, DECONTAMINATION AND LOADOUT CHAMBERS
DO NOT FIT WITHIN A ROOM, THE DECON/LOADOUT
CONFIGURATION MAY EXTEND INTO 1/2 WIDTH OF THE
HALLWAY AS REQUIRED TO ALLOW PASSAGE IN CORRIDOR.
A1
ASBESTOS KEY NOTES
REMOVE VISIBLE DEBRIS, PRE-CLEAN AND
ENCLOSE APPROXIMATELY 4,900 SF OF
ASBESTOS CONTAMINATED SOIL WITHIN A
NEGATIVE PRESSURE ENCLOSURE. INSTALL A 60
MILLIMETER THICK EPDM MEMBRANE OVER
EXPOSED SOIL SURFACE, WITH MEMBRANE
SHEETS CHEMICALLY WELDED AT 12" SEAM
OVERLAP, AND PHYSICALLY SEAL ALONG
PERIMETER EDGES USING FURRING STRIPS AND
TAP-CONS WITH MEMBRANE FOLDED OVER.
ENSURE SEAL AT BLOCK, WOOD, OR CONCRETE
WALLS, POSTS AND/OR COLUMNS, AS NEEDED TO
ENSURE AN AIR-TIGHT LAYER IS ACHIEVED AND
MAINTAINED BETWEEN SOILS AND CRAWL SPACE.
RIGOROUS PRE-CLEANING BY HEPA VACUUM AND
MANUAL WIPING OF ALL SURFACES WILL BE
NECESSARY TO ACHIEVE CLEARANCE.
ASBESTOS PIPE INSULATION REMNANTS AT
THROUGH WALL LOCATIONS, PROTECT AS
NECESSARY
REMOVE CRAWLSPACE DOOR AND FRAME WITH
LBP USING MANUAL METHODS WITHIN EXISTING
NEGATIVE PRESSURE CONTAINMENT, 2 DOORS
AND FRAMES.
LBP PRESENT ON STAIR RAIL, AIR VENTS, DOOR
SYSTEM AND STRUCTURAL STEEL BEAMS,
PROTECT AS NECESSARY
AREA OF EPDM ENCLOSURE, ASBESTOS
CONTAMINATED SOIL
2000 CFM AIR MACHINES WITH 3 STAGE
FILTRATION
3-STAGE WET DECONTAMINATION
A2
D
N
N
D
L1
L2
L1
L2
L1
BID DOCUMENTS