Attachment 4 Drawing 04_ARCHITECTURAL_BID SET.pdf

PDF 2 MB Posted

Attached to
Y1DA--610A4-21-701 EHRM Infrastructure Upgrades Construction Ft. Wayne Federal contract opportunity
Solicitation number
36C77622B0028
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document package includes construction drawings and specifications for infrastructure upgrades at a Department of Veterans Affairs medical center. The project involves telecommunications and electrical infrastructure upgrades, including demolition and construction of new walls, installation of access doors, and replacement of telecom room doors with new dual authentication access panels. Work will take place in various buildings on the medical center campus and includes the main server room. Finishes and partitions are specified. The related federal contract opportunity is a firm-fixed-price construction solicitation issued by the VA Technology Acquisition Center for the project with a response deadline of January 10, 2022.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--610A4-21-701 EHRM Infrastructure Upgrades Construction Ft. Wayne, newest first.
File Type Posted
36C77622B0028 0008.pdf PDF
Attachment 2 EHRM ICRA Form - Ft. Wayne.pdf PDF
Attachment 1 Technical Question Responses - Ft Wayne EHRM 20220722.pdf PDF
36C77622B0028 0007.pdf PDF
36C77622B0028 0006.pdf PDF
0006 Attachment 1 Technical Question Responses.pdf PDF
36C77622B0028 0005.pdf PDF
36C77622B0028 0004.pdf PDF
36C77622B0028 0003.pdf PDF
36C77622B0028 0002.pdf PDF
36C77622B0028 0001.pdf PDF
Attachment 12 610A4-21-701 Specifications Bound.pdf PDF
Attachment 3 Drawing 03_ENVIRONMENTAL.pdf PDF
Attachment 9 Drawing 08b_TELECOMMUNICATION.pdf PDF
Attachment 14 COVID-19 Safety Protocols 12-14-21.pdf PDF
36C77622B0028_1.docx DOCX document
Attachment 17 ELECTRICAL BID SET.pdf PDF
Attachment 16 Limitations on Subcontracting - Construction.docx DOCX document
Attachment 13 DBA Wage Determination - Ft Wayne 20220602.pdf PDF
Attachment 11 EHRM Ft Wayne Bid Documents Narrative.pdf PDF
Attachment 10 Drawing 09_SECURITY.pdf PDF
Attachment 7 Drawing 07_ELECTRICAL_BID SET.pdf PDF
Attachment 6 Drawing 06_MECHANICAL_BID SET.pdf PDF
Attachment 5 Drawing 05_FIRE PROTECTION_BID SET.pdf PDF
Attachment 2 Drawing 02_CIVIL_BID SET.pdf PDF
Attachment 15 CONTRACTOR SAFETY AND ENVIRONMENTAL RECORD EVALUATION FORM.docx DOCX document
Attachment 8 Drawing 08a_TELECOMMUNICATION.pdf PDF
Attachment 1 Drawing 01_GENERAL_BID SET.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FD

MAIN SERVER ROOM

MAIN SERVER ROOM

OFFICE

2.16

2.52

2.532.53 2.532.53

2.53

2.53

2.53

2.542.54

2.602.60

2.612.61

2.84 2.84

2.832.83

2.16

3'-0"

2.80

2.82

2.812.81

7'

-1

21'-10"

TELECOM ROOM /

TCB

TELECOM ROOM /

TCB

2.532.53

2.62 2.16

HAC

063A

2.72

2.73

2.62

2.16

2.85

9'-7"

TELECOM ROOM

528C

TELECOM ROOM

528C

2.84

2.532.53

2.87

MECH

A155

MECH

A155

2.51

2.55

2.532.53

2.57 2.56

2.602.60

ALCOVE

2.16

2.55

TELECOM ROOM

176A

TELECOM ROOM

176A

DATA

DATA

2.532.53

2.26

2.882.86

2.87

2.88

2.83

TELECOM ROOM

TELECOM ROOM

2.84

2.532.53

2.65

2.67

2.84 2.16

2.90

2.90

7'-8"

BREAK

BREAK

2.51

MECH

210C

2.68

2.702.70

2.702.70

2.71

2.69 2.89

BID ALTERNATE OPTION 2

TELECOM ROOM

TELECOM ROOM

2.84

2.90

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING

HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.

4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS BEEN

INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.

5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.

6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN

EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN

FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO

EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE

PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE

MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO

ROOMS OUTSIDE OF SCOPE WITH OWNER.

GENERAL DEMOLITION NOTES

BLDG 3

BLDG T4, T5, T6

BLDG 6BLDG 5

BLDG 2 BLDG 4

N

KEY PLAN - BLDG 1, 2, 3, 4, 5, 6 T4, T5, & T6

BLDG 1

TELECOM ROOM

B606

TELECOM ROOM

B606

ELECTRICAL

B607

CART PREP

B605

2.62 th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

BLDG 1 - DEMOLITION PLANS

BAB 30 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

AD111

SPUR # 1791.10

N

1/4" = 1'-0"

BLDG 1 - BASEMENT DEMO PLAN1

N

1/4" = 1'-0"

BLDG 1 - BASEMENT DEMO PLAN3

N

1/4" = 1'-0"

BLDG 1 - FIFTH FLOOR DEMO PLAN9

N

1/4" = 1'-0"

BLDG 1 - FIRST FLOOR DEMO PLAN5

N

1/4" = 1'-0"

BLDG 1 - FIRST FLOOR DEMO PLAN4

N

1/4" = 1'-0"

BLDG 1 - FOURTH FLOOR DEMO PLAN8

N

1/4" = 1'-0"

BLDG 1 - SECOND FLOOR DEMO PLAN6

N

1/4" = 1'-0"

BLDG 1 - THIRD FLOOR DEMO PLAN7

KEYNOTE LEGEND

2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED.

2.26 REMOVE AND RETAIN EXISTING DOOR AND FRAME. SALVAGED DOOR AND FRAME TO BE

RETURNED TO VA.

2.51 BID DEDUCT OPTION 2 - DEMOLISH EXISTING IT CAGE

2.52 EXISTING ROOF DRAIN PIPE TO REMAIN IN PLACE.

2.53 EXISTING EQUIPMENT TO BE REMOVED OR RELOCATED. REFERENCE ELECTRICAL

DRAWINGS.

2.54 DEMOLISH EXISTING RAISED ACCESS FLOORING IN ITS ENTIRETY.

2.55 EXISTING EQUIPMENT TO BE RELOCATED.

2.56 REMOVE EXISTING WALLPAPER FINISH.

2.57 DEMOLISH EXISTING GUARDRAIL.

2.60 DEMOLISH EXISTING CEILING, FIXTURES, DIFFUSERS, AND EQUIPMENT. REFERENCE MEP

DRAWINGS FOR MORE INFORMATION.

2.61 EXISTING EQUIPMENT ABOVE CEILING TO BE RELOCATED. REFERENCE MEP DRAWINGS FOR

MORE INFORMATION.

2.62 REMOVE EXISTING DOOR AND SALVAGE FOR REINSTALLATION WITH NEW HARDWARE.

2.65 EXISTING EXPANSION JOINT TO REMAIN AND BE PROTECTED DURING CONSTRUCTION.

2.67 EXISTING DRIP PAN ABOVE TO REMAIN AND BE PROTECTED DURING CONSTRUCTION.

2.68 BID DEDUCT OPTION 2 - REMOVE AND RETAIN EXISTING DOOR AND FRAME. SALVAGED DOOR

AND FRAME TO BE RETURNED TO VA.

2.69 BID DEDUCT OPTION 2 - EXISTING IT CAGE TO REMAIN.

2.70 BID DEDUCT OPTION 2 - EXISTING EQUIPMENT TO BE REMOVED OR RELOCATED. REFERENCE

ELECTRICAL DRAWINGS.

2.71 BID DEDUCT OPTION 2 - RREMOVE WINDOW GLASS WITH ASBESTOS GLAZING AND WINDOW

SYSTEM WITH LEAD BASED PAINT. REFER TO HAZARDOUS MATERIALS DRAWINGS FOR MORE

INFORMATION.

2.72 EXISTING PLUMBING TO BE RELOCATED TO NEW WALL LOCATION.

2.73 EXISTING FLOOR DRAIN TO BE RELOCATED.

2.80 REMOVE ASBESTOS FLOOR TILE AND UNDERLYING ASBESTOS BLACK MASTIC. REFER TO

HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

2.81 REMOVE EXISTING WINDOW GLASS WITH ASBESTOS GLAZING AND RESIDUE. REFER TO

HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

2.82 REMOVE ASBESTOS PIPE FITTINGS AND ASSOCIATED PIPE INSULATION. REFER TO

HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

2.83 REMOVE EXISTING WINDOW SYSTEMS WITH LEAD-BASED PAINT. REFER TO HAZARDOUS

MATERIALS DRAWINGS FOR MORE INFORMATION.

2.84 REMOVE EXISTING DOOR AND FRAME WITH LEAD-BASED PAINT. REFER TO HAZARDOUS

MATERIALS DRAWINGS FOR MORE INFORMATION.

2.85 REMOVE EXISTING LEAD-CONTAINING WALL TILE. REFER TO HAZARDOUS MATERIALS

DRAWINGS FOR MORE INFORMATION.

2.86 REMOVE NON-ASBESTOS METAL SPLINE CEILING AND ASBESTOS PIPE INSULATION. REFER

TO HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

2.87 REMOVE NON-ASBESTOS SHEET FLOORING AND UNDERLYING ASBESTOS BLACK MASTIC.

REFER TO HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

2.88 REMOVE WINDOW GLASS WITH ASBESTOS GLAZING AND RESIDUE. REFER TO HAZARDOUS

MATERIALS DRAWINGS FOR MORE INFORMATION.

2.89 BID DEDUCT OPTION 2 - REMOVE CONTAMINATED CEILING TILE AS REQUIRED. REFER TO

HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

2.90 REMOVE NON-ASBESTOS FLOOR TILE AND UNDERLYING ASBESTOS BLACK MASTIC. REFER

TO HAZARDOUS MATERIALS DRAWINGS FOR MORE INFORMATION.

N

1/4" = 1'-0"

BLDG 1 - BASEMENT ENLARGED PLAN2

No. REVISION DESCRIPTION DATE

WAIVER APPROVED TO

DEFER RENOVATION OF

THIS ROOM.

AE111

AE111

AD111

AD111

AD111

AE111

AE111

AE111

AD111

AD111

AE111

AD111

AE111

AD111

AE111

AD111

AE111

AD111

BLDG 3

BLDG T4, T5, T6

BLDG 6BLDG 5

BLDG 2 BLDG 4

N

KEY PLAN - BLDG 1, 2, 3, 4, 5, 6 T4, T5, & T6

BLDG 1

1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON

EACH FLOOR WITHIN EACH BUILDING.

2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW

CONSTRUCTION WITHIN AND ADJACENT TO EACH ROOM.

GENERAL PLAN NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

BLDG 1- REFERENCE PLAN

BAB 28 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

A-101

SPUR # 1791.10

N

1" = 40'-0"

BLDG 1- BASEMENT OVERALL PLAN1

N

1" = 40'-0"

BLDG 1- FIRST FLOOR OVERALL PLAN2

N

1" = 40'-0"

BLDG 1- SECOND FLOOR OVERALL PLAN3

N

1" = 40'-0"

BLDG 1- THIRD FLOOR OVERALL PLAN4

N

1" = 40'-0"

BLDG 1- FOURTH FLOOR OVERALL PLAN5

N

1" = 40'-0"

BLDG 1 - FIFTH FLOOR OVERALL PLAN6

No. REVISION DESCRIPTION DATE

UP U

P

U P

U P

U P

U P

UP

AD112

BLDG 3

BLDG T4, T5, T6

BLDG 6BLDG 5

BLDG 2 BLDG 4

N

KEY PLAN - BLDG 1, 2, 3, 4, 5, 6 T4, T5, & T6

BLDG 1

AE112

AD112

AE112

AD112

AE112

AD112

AE112

AD112

AE112

AD112

AE112

AD112

AE112

AD112

1. OVERALL PLANS ARE ONLY INCLUDED TO SHOW GENERAL LOCATION OF IN-SCOPE SPACES ON

EACH FLOOR WITHIN EACH BUILDING.

2. REFER TO ENLARGED PLANS FOR ADDITIONAL INFORMATION REGARDING DEMOLITION AND NEW

CONSTRUCTION WITHIN AND ADJACENT TO EACH ROOM.

GENERAL PLAN NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

BLDG 2,3,4,5,6 & T4-T6 REFERENCE

PLANS

BAB 29 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

A-102

SPUR # 1791.10

N

1/16" = 1'-0"

BLDG 2- FIRST FLOOR PLAN1

N

1/16" = 1'-0"

BLDG 3- BASEMENT PLAN2

N

1/16" = 1'-0"

BLDG 4- BASEMENT PLAN3

N

1/16" = 1'-0"

BLDG 5- BASEMENT PLAN4

N

1/16" = 1'-0"

BLDG 6 - FIRST FLOOR PLAN5

N

1/16" = 1'-0"

BLDG T4, T5, & T6 - FIRST FLOOR PLAN6

2, 3, 4, 5, 6, T4, T5, T6

U P

OFFICE

OFFICE

2.63

17 SF

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

TELECOM ROOM

2.26

2.532.53

2.59

2.59

BASEMENT

BASEMENT

2.16 2.92

TELECOM ROOM

TELECOM ROOM

2.262.532.53

BASEMENT

BASEMENT

2.59

2.59

2.53 2.532.53

2.59

2.59

2.26

BASEMENT

BASEMENT

TELECOM ROOM

2.16

2.91

TELECOM ROOM

TELECOM ROOM

2.532.53

2.26TELECOM ROOM

TELECOM ROOM

2.532.26

2.21

1. ALL EXISTING WALL DIMENSIONS ARE TO FINISH FACE, UNLESS NOTED OTHERWISE.

2. THE CONTRACTOR SHALL VERIFY DIMENSIONS OF AS-BUILT CONDITIONS, AND NOTIFY THE

ARCHITECT IN WRITING OF ANY DISCREPANCIES. ALL INFORMATION SHOWN ON THE

CONSTRUCTION DOCUMENTS IS BASED ON FIELD OBSERVATIONS AND/OR THE ORIGINAL

CONSTRUCTION DOCUMENTS OF THE FACILITY.

3. DEMOLITION AND CONSTRUCTION WORK MUST BE DONE UNDER NEGATIVE PRESSURE UTILIZING

HEPA FILTRATION UNITS. SEE INFECTION CONTROL NOTES.

4. DO NOT REMOVE BARRIERS FROM WORK AREA UNTIL COMPLETED PROJECT OT AREA HAS BEEN

INSPECTED BY THE SAVAHCS SAFETY OFFICER AND INFECTION CONTROL COORDINATOR AND

THOROUGHLY CLEANED BY ENVIRONMENTAL MANAGEMENT SERVICES.

5. THE CONTRACTOR SHALL PROVIDE PROTECTIVE COVERING FOR EXISTING FLOOR, WALL AND

CEILING FINISHES IN EXISTING AREAS NOT DESIGNATED FOR DEMOLITION OR NEW

CONSTRUCTION. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE REPAIR OF ANY DAMAGE

CAUSED BY HIS WORK OR ANY SUBCONTRACTOR.

6. THE CONTRACTOR SHALL VERIFY THAT NEW MECHANICAL SYSTEMS CAN BE INSTALLED IN

EXISTING SPACES TO CLEAR EXISTING CEILING AND OTHER CONSTRUCTED ITEMS AND MAINTAIN

FLOOR TO CEILING HEIGHTS INDICATED ON DRAWINGS. IF DISCREPANCIES OCCUR DUE TO

EXISTING CONDITIONS, CONSULT WITH THE ARCHITECT BEFORE PROCEEDING.

7. THE FINISH FACE OF MATERIAL OF NEW PARTITIONS SHALL ALIGN ON BOTH SIDES OF THE PARTITION WITH THE FACE OF THE MATERIALS ON EXISTING COLUMNS, WALLS, OR PARTITIONS, UNLESS NOTED OTHERWISE.

8. NO WORK TO BE DONE IN AREAS HATCHED GRAY IN PLANS, HOWEVER WORK MIGHT NEED TO BE

PERFORMED IN CEILING OR EXISTING CHASES THROUGHOUT BUILDING. REFERENCE

MECHANICAL AND ELECTRICAL DRAWINGS FOR EXTENT OF WORK. COORDINATE ACCESS TO

ROOMS OUTSIDE OF SCOPE WITH OWNER.

GENERAL DEMOLITION NOTES

BLDG 3

BLDG T4, T5, T6

BLDG 6BLDG 5

BLDG 2 BLDG 4

N

KEY PLAN - BLDG 1, 2, 3, 4, 5, 6 T4, T5, & T6

BLDG 1

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

BLDG 2,3,4,5,6 & T4-T6 DEMOLITION

PLANS

BAB 31 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

AD112

SPUR # 1791.10

N

1/4" = 1'-0"

BLDG 2 - FIRST FLOOR DEMOLITION PLAN1

N

1/4" = 1'-0"

BLDG 3 - BASEMENT DEMOLITION PLAN2

N

1/4" = 1'-0"

BLDG 4 - BASEMENT DEMOLITION PLAN3

N

1/4" = 1'-0"

BLDG 5 - BASEMENT DEMOLITION PLAN4

N

1/4" = 1'-0"

BLDG 6 - FIRST FLOOR DEMOLITION PLAN5

N

1/4" = 1'-0"

BLDG T4 - FIRST FLOOR DEMOLITION PLAN6

2, 3, 4, 5, 6, T4, T5, T6

KEYNOTE LEGEND

2.16 DEMOLISH EXISTING WALL CONSTRUCTION TO EXTENT INDICATED.

2.21 DEMOLISH EXISTING CASEWORK AND/OR COUNTER IN ITS ENTIRETY.

2.26 REMOVE AND RETAIN EXISTING DOOR AND FRAME. SALVAGED DOOR AND FRAME TO BE

RETURNED TO VA.

2.53 EXISTING EQUIPMENT TO BE REMOVED OR RELOCATED. REFERENCE ELECTRICAL

DRAWINGS.

2.59 EXISTING CRAWL SPACE OPENING.

2.63 EXISTING DATA CAGE TO REMAIN IN PLACE.

2.91 REMOVE CRAWLSPACE DOOR AND FRAME WITH LEAD-BASED PAINT. REFER TO HAZARDOUS

MATERIALS DRAWINGS FOR MORE INFORMATION.

2.92 EXISTING FIRE ALARM PANEL TO REMAIN IN PLACE. PROTECT DURING DEMOLITION AND

CONSTRUCTION.

BASE

PLAN

HEAD

METAL STUD U-TRACK (TOP AND BOTTOM)

WALL FINISH

(MATCH EXISTING ADJACENT FINISHES.)

WIDTH

ACTUAL

5/8"

WIDTH

STUD 5/8"

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR

BASE - (MATCH EXISTING ADJACENT FINISHES.)

DIM DIM

METAL STUD PER SCHEDULE

A3

BASIC PARTITION

ASSEMBLY CATEGORY

FRAMING UNIT

SIZE CATEGORY

PARTITION TAG

PARTITION

PER PLAN

TYPICAL PARTITION TAG

BASE

PLAN

HEAD

METAL STUD U-TRACK (TOP AND BOTTOM)

WALL FINISH

(MATCH EXISTING ADJACENT FINISHES.)

WIDTH

ACTUAL

5/8"

WIDTH

STUD 5/8"

5/8" GYPSUM BOARD EACH SIDE

FIN FLOOR

BASE - (MATCH EXISTING ADJACENT FINISHES.)

BATT INSULATION

ACOUSTICAL SEALANT AROUND

PERIMETER (INSULATED WALLS)

DIM DIM

METAL STUD PER SCHEDULE

BASE

PLAN

HEAD

WIDTH

ACTUAL

FINISH FLOOR

BASE - (MATCH EXISTING ADJACENT FINISHES.)

DIM DIM

NEW INFILL MASONRY WALL CONSTRUCTION TO

MATCH EXISTING ADJACENT CONSTRUCTION.

PAINT TO MATCH EXISTING CMU WALL.

EXISTING MASONRY WALL CONSTRUCTION

1. PAINT CONTINUOUS 4" TALL, STENCILED LETTERS, ABOVE CEILING, ON BOTH SIDES OF ALL FIRE AND SMOKE WALLS DESIGNATING THE PARTITION RATING INDICATED ON THE LIFE SAFETY PLAN.

2. ALL SUSPENDED WALLS AND PARTITIONS SHALL HAVE GYPSUM BOARD WHICH EXTENDS A

MINIMUM OF 6" ABOVE THE SUSPENDED CEILING UNLESS SHOWN AND/OR NOTED OTHERWISE BY

THE ARCHITECT.

3. "ALIGN" MEANS SIMILAR COMPONENTS OF CONSTRUCTION, E.G. WALLS, JAMBS, ETC. SHALL

ALIGN ACROSS VOIDS AND JOINTS.

4. PARTITIONS SHALL BE CONTINUOUS OVER DOORS SAME ADJACENT WALLS (UNLESS NOTED

OTHERWISE) WHERE GYPSUM BOARD CONTINUES ABOVE CEILING AND ABOVE THE CEILING

LEVEL UP TO THE STRUCTURE ABOVE. ALL GYPSUM BOARD RETURNS SHALL HAVE CORNER

BEADS MINIMUM FLOOR TO CEILING. ALL PENETRATIONS IN GYPSUM BOARD CONSTRUCTION

ABOVE FINISHED CEILING SHALL BE EFFECTIVELY SEALED TO PREVENT SOUND LEAKAGE AND

FIRE STOPPING TAPE/CAULK AT ALL RATED PARTITIONS.

5. ALL MECHANICAL CHASES AND OTHER NOTED CHASES ARE TO EXTEND UP TO THE UNDERSIDE

OF THE DECK STRUCTURE ABOVE. ALL PLUMBING CHASES UNLESS OTHERWISE NOTED, SHALL

EXTEND ABOVE THE HIGHEST ADJOINING CEILING AND BE BRACED TO STRUCTURE.

6. ALL CONSTRUCTION DESIGNATED TO BE SUPPORTED BY ROOF STRUCTURE SHALL BE

SUPPORTED BY TOP CHORD OF STRUCTURAL JOISTS AND NOT FROM THE METAL DECK.

7. IMPACT RESISTANT GYPSUM BOARD, WHERE NOTED, IS OPTIONAL ABOVE 8' AFF AND BEHIND

LOCKERS.

8. SEAL THE TOP AND BOTTOM OF WALL AS WELL AS ALL PENETRATIONS WHERE SMOKE

PARTITIONS ARE DESIGNATED ON THE LIFE SAFETY PLAN TO ELIMINATE THE PASSAGE OF

SMOKE.

9. USE DEFLECTION TRACKS WHERE STUD WALLS ATTACH DIRECTLY TO METAL DECK.

GENERAL PARTITION NOTES

2" S

C H

E D

. D

IM

2"

DIM.

SCHED. 2"

FFE

STANDARD FRAMEF

SCHED. DIM.

S C

H E

D . D

IM

FFE

FLUSH

2" 5/

8"

1 15/16" VARIES 1 9/16"

1/2"

INT. STUD WALLS

WALL THICKNESS AT 1/2"

RE: DOOR SCHEDULE

FRAME DEPTH

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

PARTITION TYPES, DOOR SCHEDULE &

FINISH SCHEDULE

ZDL 32 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

AE021

SPUR # 1791.10

MARK WALL TYPE DESCRIPTION WIDTH

E8 EXISTING

NEW MASONRY INFILL CONSTRUCTION TO MATCH

ADJACENT EXISTING CONSTRUCTION

7 5/8"

MARK WALL TYPE DESCRIPTION WIDTH

C3 INSULATED

1 HOUR RATED - 5/8" GYPSUM BOARD EACH SIDE OF 3

5/8" METAL STUD @ 16" O.C. UL#419

4 7/8"

MARK WALL TYPE DESCRIPTION WIDTH

A3 NON-INSULATED

1 LAYER 5/8" GYPSUM BOARD ON ONE SIDE OF 3 5/8"

METAL STUD @ 16" O.C.

4 1/4"

DOOR SCHEDULE

MARK ROOM NAME

DOOR PANEL FRAME

HARDWARE

SET

COMMENTS

TYPE MATERIAL WIDTH HEIGHT FIRE RATING TYPE

FIRE

RATING

057 MAIN SERVER ROOM PAIR-F WD 6'-0" 7'-0" 2 HR HM-1 1 HR 2 NEW DUAL AUTHENTICATION PACS

063 TELECOM ROOM / TCB F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

063A HAC F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 -

106 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 NEW DUAL AUTHENTICATION PACS

107 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

154 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 NEW DUAL AUTHENTICATION PACS

176A TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

210C TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1

1 HR

SEE BID DEDUCT ONE ON SHEET GI001 - GENERAL INFORMATION. NEW

DUAL AUTHENTICATION PACS

301 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 NEW DUAL AUTHENTICATION PACS

401 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

501 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 NEW DUAL AUTHENTICATION PACS

528C TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

3302 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

4308 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 DUAL AUTHENTICATION PACS TO REPLACE EXISTING CARD READER

B606 TELECOM ROOM F WD 3'-0" 7'-0" 45 MIN. HM-1 1 HR 1 NEW DUAL AUTHENTICATION PACS

1/4" = 1'-0"

HOLLOW METAL FRAME ELEVATIONS

1/4" = 1'-0"

DOOR TYPES

3" = 1'-0"

DOOR FRAME TYPE

ROOM FINISH SCHEDULE

ROOM # ROOM NAME

FLOOR FINISHES WALL FINISHES

CEILING

MATERIAL BASE NORTH EAST SOUTH WEST

057 MAIN SERVER ROOM SDT1 RB1 P1 P1 P1 P1 NO CEILING

063 TELECOM ROOM / TCB SDT1 RB1 P1 P1 P1 P1 NO CEILING

154 TELECOM ROOM SDT1 RB1 P1 P1 P1 P1 NO CEILING

301 TELECOM ROOM SDT1 RB1 P1 P1 P1 P1 NO CEILING

501 TELECOM ROOM SDT1 RB1 P1 P1 P1 P1 NO CEILING

No. REVISION DESCRIPTION DATE

FINISH LEGEND

ABBREVIATION MATERIAL MANUFACTURER SERIES / COLLECTION COLOR SIZE(S) COMMENTS

RB1 RUBBER BASE TARKETT TIGHTLOCK WALL BASE SYSTEM FOR RESILIENT 80 FAWN CB COLORMATCH 4.375" HEIGHT

SDT1 STATIC DISSIPATIVE TILE ARMSTRONG FLOORING EXCELON SDT MARBLE BEIGE 12" X 12"

P1 WALL PAINT, FIELD SHERWIN WILLIAMS PROMAR 700 LATEX PAINT - - MATCH EXISTING ADJACENT

FD

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE ON SHEET AE-021 FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. EXTEND ALL EXISTING GYPSUM BOARD WALLS TO BOTTOM OF DECK WITH TYPE X GYMPSJUM

BOARD AND SEAL TO DECK.

5. SEAL ALL EXISTING PENETRATIONS WITH FIRE CAULK.

6. LOCATE NEW FIRE EXTINGUISHER IN NEW CABINET AT LOCATION SELECTED BY VA WITHIN 75

FEET OF EACH TELECOM ROOM.

7. BID ALTERNATE OPTION 2: DEDUCT ROOM 210C DEMOLITION AND NEW CONSTRUCTION FROM

PROJECT SCOPE. LEAVE EXISTING IT CAGE IN PLACE AND RUN NEW FIBER IN PREPARATION FOR

FUTURE RENOVATION.

GENERAL PLAN NOTES

MECH

A155

MECH

A155

TELECOM ROOM

100 SF / 81 SF

ALIGN C3

F .V

'-9

15'-6"

ALIGN

A3

C3C3

TELECOM ROOM

100 SF / 117 SF

176A

DATA

DATA

6A

4.21

MAIN SERVER ROOM

877 SF

4.21

E8

4.21

7'-10 1/2" 2'-7" 7'-9 1/2"

TELECOM ROOM / TCB

100 SF / 100 SF

'-6

HAC

64 SF

063A

063A

C3

4.21

TELECOM ROOM

100 SF / 56 SF

B606

ELECTRICAL

B607

CART PREP

B605

B

BREAK

BREAK

TELECOM ROOM

100 SF / 117 SF

210C

0C

4.21

BID ALTERNATE OPTION 2

TELECOM ROOM

100 SF / 90 SF

TELECOM ROOM

100 SF / 117 SF

C3

TELECOM ROOM

100 SF / 106 SF

528C

528C

BLDG 3

BLDG T4, T5, T6

BLDG 6BLDG 5

BLDG 2 BLDG 4

N

KEY PLAN - BLDG 1, 2, 3, 4, 5, 6 T4, T5, & T6

BLDG 1

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

BLDG 1 - ENLARGED PLANS

BAB 33 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

AE111

SPUR # 1791.10

N

1/4" = 1'-0"

BLDG 1 - FIRST FLOOR ENLARGED PLAN5

N

1/4" = 1'-0"

BLDG 1 - FIRST FLOOR ENLARGED PLAN4

N

1/4" = 1'-0"

BLDG 1 - BASEMENT ENLARGED PLAN1

N

1/4" = 1'-0"

BLDG 1 - BASEMENT ENLARGED PLAN3

N

1/4" = 1'-0"

BLDG 1 - BASEMENT ENLARGED PLAN2

N

1/4" = 1'-0"

BLDG 1 - SECOND FLOOR ENLARGED PLAN6

N

1/4" = 1'-0"

BLDG 1 - THIRD FLOOR ENLARGED PLAN7

N

1/4" = 1'-0"

BLDG 1 - FOURTH FLOOR ENLARGED PLAN8

N

1/4" = 1'-0"

BLDG 1 - FIFTH FLOOR ENLARGED PLAN9

KEYNOTE LEGEND

4.21 NEW WALL INFILL TO MATCH EXISTING ADJACENT WALL CONSTRUCTION.

No. REVISION DESCRIPTION DATE

WAIVER APPROVED TO

DEFER RENOVATION OF

THIS ROOM.

UP

TELECOM ROOM

170 SF / 63 SF

BASEMENT

BASEMENT

5.31

5.31

7' -0

10'-6"

3'-1" 5"

C3C3C3

C3C3

A3

3' -1

0"

TELECOM ROOM

170 SF / 29 SF

BASEMENT

BASEMENT

5.31

5.31

TELECOM ROOM

170 SF / 82 SF

BASEMENT

BASEMENT

5.31

8' -6

5.31

C3

C3

C3

10'-3" 4'-0"

C3

3' -0

TELECOM ROOM

170 SF / 46 SF

TELECOM ROOM

170 SF / 23 SF

BLDG 3

BLDG T4, T5, T6

BLDG 6BLDG 5

BLDG 2 BLDG 4

N

KEY PLAN - BLDG 1, 2, 3, 4, 5, 6 T4, T5, & T6

BLDG 1

1. ALL DOOR FRAMES TO BE LOCATED 4" FROM OUTSIDE OF FRAME TO FINISH FACE OF ADJACENT

WALL UNLESS NOTED OTHERWISE.

2. REFER TO DOOR SCHEDULE ON SHEET AE-021 FOR DOOR INFORMATION.

3. ALL WALLS ARE DIMENSIONED TO CENTERLINE OF METAL STUD, UNLESS NOTED OTHERWISE.

4. EXTEND ALL EXISTING GYPSUM BOARD WALLS TO BOTTOM OF DECK WITH TYPE X GYMPSJUM

BOARD AND SEAL TO DECK.

5. SEAL ALL EXISTING PENETRATIONS WITH FIRE CAULK.

6. LOCATE NEW FIRE EXTINGUISHER IN NEW CABINET AT LOCATION SELECTED BY VA WITHIN 75

FEET OF EACH TELECOM ROOM.

7. BID ALTERNATE OPTION 2: DEDUCT ROOM 210C DEMOLITION AND NEW CONSTRUCTION FROM

PROJECT SCOPE. LEAVE EXISTING IT CAGE IN PLACE AND RUN NEW FIBER IN PREPARATION FOR

FUTURE RENOVATION.

GENERAL PLAN NOTES

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project Number

CONSULTANTS:

Drawing #

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

IN ARCH REG. NO. AR12100034 EXP. 12/31/2021

IN MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

IN ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

The information on this document is preliminary or incomplete, not for construction, recording purposes, or implementation.

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATION

ASPEN COMMUNICATIONS, LLC

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSICAL SECURITY

FORCE PROTECT

10901 FRONT BEACH RD, UNIT 1415

PANAMA CITY BEACH, FL 32407

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

/1

/2

:0 :5

P

M

BLDG 2,3,4,5,6 & T4-T6 ENLARGED

PLANS

BAB 34 OF 120AJS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

11/12/2021

610A4-21-701

VANIHCS

2121 LAKE AVE,

FORT WAYNE, IN 46805

AE112

SPUR # 1791.10

N

1/4" = 1'-0"

BLDG 3 - BASEMENT ENLARGED PLAN1

N

1/4" = 1'-0"

BLDG 4 - BASEMENT ENLARGED PLAN2

N

1/4" = 1'-0"

BLDG 5 - BASEMENT ENLARGED PLAN3

N

1/4" = 1'-0"

BLDG 6 - FIRST FLOOR ENLARGED PLAN4

N

1/4" = 1'-0"

BLDG T4, T5, & T6 - FIRST FLOOR ENLARGED PLAN5

2, 3, 4, 5, 6, T4, T5, T6

KEYNOTE LEGEND

5.31 INSTALL LOCKABLE ACCESS DOOR ON CRAWLSPACE ENTRY ADJACENT TO ROOM.

Sheets
AD111 - BLDG 1 - DEMOLITION PLANS
A-101 - BLDG 1- REFERENCE PLAN
A-102 - BLDG 2,3,4,5,6 & T4-T6 REFERENCE PLANS
AD112 - BLDG 2,3,4,5,6 & T4-T6 DEMOLITION PLANS
AE021 - PARTITION TYPES, DOOR SCHEDULE & FINISH SCHEDULE
AE111 - BLDG 1 - ENLARGED PLANS
AE112 - BLDG 2,3,4,5,6 & T4-T6 ENLARGED PLANS

File details come from the government source that posted it. Updated .