Attachment 8 Drawing 08a_TELECOMMUNICATION.pdf

PDF 9 MB Posted

Attached to
Y1DA--610A4-21-701 EHRM Infrastructure Upgrades Construction Ft. Wayne Federal contract opportunity
Solicitation number
36C77622B0028
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document outlines requirements for an EHRM infrastructure upgrade construction project at the VA Medical Center in Fort Wayne, Indiana. Key details include upgrading the fiber optic backbone, installing new Category 6A cabling to approximately 656 work area outlets across two phases, and replacing telecommunications room equipment. The solicitation was issued by the VA Technology Acquisition Center and involves upgrading the medical center's IT and telecommunications systems. The response due date is not provided.

View the file

Other files for this federal contract opportunity

Other files attached to Y1DA--610A4-21-701 EHRM Infrastructure Upgrades Construction Ft. Wayne, newest first.
File Type Posted
36C77622B0028 0008.pdf PDF
Attachment 2 EHRM ICRA Form - Ft. Wayne.pdf PDF
Attachment 1 Technical Question Responses - Ft Wayne EHRM 20220722.pdf PDF
36C77622B0028 0007.pdf PDF
0006 Attachment 1 Technical Question Responses.pdf PDF
36C77622B0028 0006.pdf PDF
36C77622B0028 0005.pdf PDF
36C77622B0028 0004.pdf PDF
36C77622B0028 0003.pdf PDF
36C77622B0028 0002.pdf PDF
36C77622B0028 0001.pdf PDF
Attachment 12 610A4-21-701 Specifications Bound.pdf PDF
Attachment 3 Drawing 03_ENVIRONMENTAL.pdf PDF
Attachment 9 Drawing 08b_TELECOMMUNICATION.pdf PDF
Attachment 14 COVID-19 Safety Protocols 12-14-21.pdf PDF
36C77622B0028_1.docx DOCX document
Attachment 15 CONTRACTOR SAFETY AND ENVIRONMENTAL RECORD EVALUATION FORM.docx DOCX document
Attachment 4 Drawing 04_ARCHITECTURAL_BID SET.pdf PDF
Attachment 1 Drawing 01_GENERAL_BID SET.pdf PDF
Attachment 17 ELECTRICAL BID SET.pdf PDF
Attachment 16 Limitations on Subcontracting - Construction.docx DOCX document
Attachment 13 DBA Wage Determination - Ft Wayne 20220602.pdf PDF
Attachment 11 EHRM Ft Wayne Bid Documents Narrative.pdf PDF
Attachment 10 Drawing 09_SECURITY.pdf PDF
Attachment 7 Drawing 07_ELECTRICAL_BID SET.pdf PDF
Attachment 6 Drawing 06_MECHANICAL_BID SET.pdf PDF
Attachment 5 Drawing 05_FIRE PROTECTION_BID SET.pdf PDF
Attachment 2 Drawing 02_CIVIL_BID SET.pdf PDF
Show all 28

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ABBREVIATIONS

STANDARD MOUNTING HEIGHTSANNOTATION

ELECTRICAL:

AUDIBLE APPLIANCES (CENTERLINE) 84"

ALARMS 48"

ANNUNCIATOR PANELS 48"

CLOCK OUTLETS (CENTERLINE) 84"

CONTROLS (TOP) 48"

EXIT SIGNS (WALL-MOUNTED, BOTTOM) 80"

FIRE ALARM ANNUNCIATOR PANEL (DISPLAY) 60"

FIRE ALARM BELL (EXTERIOR) 120"

FIRE ALARM CONTROL PANEL/UNIT (DISPLAY) 60"

INTERCOM (AFEA ONLY) 36"

INTERCOMS (TOP) 48"

PANELS & PANELBOARDS (TOP) 72"

PULL STATIONS (HANDLE) 48"

PHOTOCELLS 144"

RECEPTACLES (BOTTOM) 18"

RECEPTACLES (EXTERIOR) 24"

RECEPTACLES (GARAGES) 26"

RECEPTACLES IN EQUIPMENT ROOMS (TOP) 48"

REMOTE INDICATING LIGHT (EQUIPMENT ROOMS) 48"

REMOTE INDICATING LIGHT (FINISHED AREAS) CEILING

SAFETY SWITCHES & STARTERS 48"

SWITCHES (TOP) 48"

TELEPHONE/DATA/TV OUTLETS (BOTTOM) 18"

VISIBLE APPLIANCES (CENTERLINE) 84"

(AFF, AFG UNLESS NOTED OTHERWISE)

CU

MECHANICAL OR FIRE SPRINKLER PLAN NOTE CALL OUT

PLUMBING PLAN NOTE CALL OUT

ELECTRICAL, TECHNOLOGY OR FIRE ALARM PLAN NOTE

CALL OUT

PLUMBING EQUIPMENT DESIGNATION

EQUIPMENT DESIGNATION TAG

OWNER FURNISHED, CONTRACTOR INSTALLED

EQUIPMENT DESIGNATION

NEW WORK TO EXISTING WORK CONNECTION POINT

IC

CATV

FO

T

T/D

D

S

IC

UC

S

WAP

#D/#TV

M

S

V

COMMUNICATIONS OUTLET, TYPE AS NOTED

COMMUNICATIONS OUTLET, FLOOR BOX, TYPE AS NOTED

WIRELESS ACCESS POINT, CEILING MOUNTED

COMMUNICATIONS OUTLET, CEILING MTD, TYPE AS NOTED

SPEAKER, WALL MOUNTED

SPEAKER, CEILING MOUNTED

SERVER RACK, TWO-POST, FLOOR MOUNTED

3/4"x4'x8', FIRE-RATED PLYWOOD BACKBOARD

GROUND BAR, TYPE AS NOTED

SERVER RACK, WALL MOUNTED

CABLE TRAY, TYPE AS NOTED

CABLE TELEVISION LINE

FIBEROPTIC LINE

TELEPHONE LINE

TELEPHONE/DATA LINE

DATA LINE

SPEAKER LINE

INTERCOM LINE

INTERCOM, "M" DENOTES MASTER STATION

VOLUME CONTROL, WALL MOUNTED

MULTI-SERVICE POWER POLE WITH POWER/DATA,

TYPE AS NOTED AND/OR SCHEDULED

UNDERGROUND COMMUNICATIONS LINE,

CABLING TYPE AS NOTED

MULTI-SERVICE FLOOR BOX/POKE-THRU WITH POWER/DATA,

TYPE AS NOTED AND/OR SCHEDULED

SERVER RACK, FOUR-POST, FLOOR MOUNTED

SERVER CABINET, FLOOR MOUNTED

#D = DATA, # = QUANTITY OF CABLES

#TV = CABLE TELEVISION, # = QUANTITY OF CABLES

#D = DATA, # = QUANTITY OF CABLES

#TV = CABLE TELEVISION, # = QUANTITY OF CABLES

#V = VOICE, # = QUANTITY OF CABLES

#D = DATA, # = QUANTITY OF CABLES

#E = ELEVATOR, # = QUANTITY OF CABLES

#FMS = FACILITY MONITORING SYSTEM,

# = QUANTITY OF CABLES

TELECOMMUNICATIONS SYMBOLS

#TV = CABLE TELEVISION, # = QUANTITY OF CABLES

#V = VOICE, # = QUANTITY OF CABLES

M (CONT'D)

MV MEDIUM VOLTAGE

MVA MEGAVOLT-AMPERE

MW MEGAWATT

X

W

V

U

T

S

R

P

O

N

M

L

K

J

I

H

FA FIRE ALARM

FAAP FIRE ALARM ANNUNCIATOR PANEL

FABL FIRE ALARM BELL

FABX FIRE ALARM BOX

FACP FIRE ALARM CONTROL PANEL

FC FOOTCANDLE

FI FILM ILLUMINATOR

FIXT FIXTURE

FLA FULL LOAD AMPS

FLEX FLEXIBLE METALLIC CONDUIT

FLUOR FLUORESCENT

FO FIBER-OPTIC

FP FIRE PROTECTION

FT FEET OR FOOT

FVNR FULL VOLTAGE NON-REVERSING

FVR FULL VOLTAGE REVERSING

G

F

E

D

EC EMPTY CONDUIT

EG EQUIPMENT GROUND

EL ELEVATION

ELEC ELECTRIC OR ELECTRICAL

ELEV ELEVATOR

EMCP EMER. MONITORING CONTROL PANEL

EMER EMERGENCY

EMI ELECTROMAGNETIC INTERFERENCE

EMT ELECTRICAL METALLIC TUBING

ENCL ENCLOSURE

EPO EMERGENCY POWER OFF

ESMT EASEMENT

ETD EXISTING TO BE DEMOLISHED

ETR EXISTING TO REMAIN

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

EXIST EXISTING

DB DECIBEL OR DIRECT BURIAL

DC DIRECT CURRENT

DCP DIMMER CONTROL PANEL

DEG C DEGREES CELSIUS

DEG F DEGREES FAHRENHEIT

DEMO DEMOLITION

DIAG DIAGRAM

DISC DISCONNECT

DISTR DISTRIBUTION

DISTR PNL DISTRIBUTION PANEL

DN DOWN

DPDT DOUBLE POLE, DOUBLE THROW

DPST DOUBLE POLE, SINGLE THROW

DRSW DOOR SWITCH

DS DISCONNECT SWITCH

DWG DRAWING

C CONDUIT

CAP CAPACITY

CAT CATALOG

CATV COMMUNITY ANTENNA TELEVISION

CCR CONTROL CONTACTOR

CCTV CLOSED CIRCUIT TELEVISION

cd CANDELA

CD CONSTRUCTION DOCUMENTS

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/

CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER

INSTALLED

CFE CONTRACTOR FURNISHED

EQUIPMENT

CHW CHILLED WATER

CHWP CHILLED WATER PUMP

CKT CIRCUIT

CKT BRKR CIRCUIT BREAKER

CLF CURRENT LIMITING FUSE

CLG CEILING

CMU CONCRETE MASONRY UNIT

COAX COAX CABLE

COMM COMMUNICATION

CONC CONCRETE

CONT CONTINUE

CONTR CONTRACTOR

COORD COORDINATE

CPT CONTROL POWER TRANSFORMER

CRI COLOR RENDERING INDEX

CT CURRENT TRANSFORMER

CTV CABLE TELEVISION

CU COPPER

CU FT CUBIC FEET

C

B

A

UFD UNDERFLOOR DUCT

UGND UNDERGROUND

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

UPS UNINTERRUPTIBLE POWER SUPPLY

UTIL UTILITY

V VOLT

VA VOLT AMPERE

VAR VOLT AMPERE REACTIVE

VCM VERTICAL CABLE MANAGER

VFD VARIABLE FREQUENCY DRIVE

VOLT VOLTAGE

TC TIME CLOCK

TEL TELEPHONE

TP TWISTED PAIR

TPS TWISTED PAIR SHIELDED

TTB TELEPHONE TERMINAL BOARD

TV TELEVISION

TYP TYPICAL

RCP REFLECTED CEILING PLAN

RCPT RECEPTACLE

REC RECESSED

REQD REQUIRED

RGS RIGID GALVANIZED STEEL

RM ROOM

RMS ROOT MEAN SQUARE

RU RACK UNIT

N NEUTRAL

NA NOT APPLICABLE

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL

MANUFACTURERS ASSOCIATION

NFPA NATIONAL FIRE PROTECTION

ASSOCIATION

NIC NOT IN CONTRACT

NL NIGHT LIGHT

NO NORMALLY OPEN

NS NO SCALE

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER

OL OVERLOAD

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MC METAL-CLAD

MCA MINIMUM CIRCUIT AMPS

MCB MAIN CIRCUIT BREAKER

MCC MOTOR CONTROL CENTER

MDP MAIN DISTRIBUTION PANEL

MECH MECHANICAL

MG MOTOR GENERATOR

MH MANHOLE

MIN MINIMUM

MOCP MAXIMUM OVERCURRENT PROTECTION

MLO MAIN LUGS ONLY

MT MOUNT

MTD MOUNTED

MTG MOUNTING

KV KILOVOLT

KVA KILOVOLT AMPERE

KVAH KILOVOLT AMPERE PER HOUR

KVAR KILOVOLT AMPERE REACTIVE

KW KILOWATT

KWH KILOWATT HOUR

KWHM KILOWATT HOUR METER

JB JUNCTION BOX

J-BOX JUNCTION BOX

XFER TRANSFER

XFMR TRANSFORMER

XP EXPLOSION PROOF

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LM LUMEN

LP LIGHT POLE

LPS LOW PRESSURE SODIUM

LRA LOCKED ROTOR AMPS

LTCP LOCAL TEMPERATURE CONTROL PANEL

LT LIGHT

LTG LIGHTING

LTG PNL LIGHTING PANEL

LTNG LIGHTNING

LV LOW VOLTAGE

W WATT

WH WATER HEATER

WP WEATHERPROOF

IESNA ILLUMINATION ENGINEERING SOCIETY

OF NORTH AMERICA

IG ISOLATED GROUND

IMC INTERMEDIATE METAL CONDUIT

INCAND INCANDESCENT

IR INFRARED

IWH INSTANTANEOUS WATER HEATER

G OR GND GROUND OR GENERATOR

GEN GENERATOR

GFCI GROUND FAULT CIRCUIT INTERRUPTER

GTB GROUND TERMINAL BOX

SCC SHORT CIRCUIT CAPACITY

SES SERVICE ENTRANCE SECTION

SD SMOKE DETECTOR

SF SQUARE FOOT (FEET)

SHT SHEET

SI INTERNATIONAL SYSTEM OF UNITS

SPEC SPECIFICATION

SPST SINGLE POLE, SINGLE THROW

SURF SURFACE

SW SWITCH

SWBD SWITCHBOARD

SWGR SWITCHGEAR

P POLE

PA PUBLIC ADDRESS

PB PANELBOARD, PULL BOX, OR

PUSHBUTTON

PBPU PREFABRICATED BEDSIDE PATIENT UNIT

PCB POLYCHLORINATED BIPHENYL

PEC PHOTOELECTRIC CELL

PED PEDESTAL

PEND PENDANT

PF POWER FACTOR

PH PHASE

PNL PANEL

POD POWER OPERATED DAMPER

POE POWER OVER ETHERNET

PP PATCH PANEL

PT POTENTIAL TRANSFORMER

PTRV POWER TYPE ROOF VENTILATION

PVC POLYVINYL CHLORIDE (PLASTIC)

PWR POWER

1P SINGLE POLE

1PH SINGLE-PHASE

3P THREE POLE

3PH THREE-PHASE

3W THREE WIRE

4W FOUR WIRE

A/C AIR CONDITIONING

A/E ARCHITECT/ENGINEER

AAP ALARM ANNUNCIATOR PANEL

AC ALTERNATING CURRENT OR ARMORED

ACC ACCESSIBLE

ADDL ADDITIONAL

ADJ ADJACENT, ADJOINING

ADO AUTOMATIC DOOR OPENER

AF AMPERE FRAME OR AMP FUSE

AFC ABOVE FINISHED COUNTER, AUTOMATIC

FREQUENCY CONTROL, OR

AVAILABLE FAULT CURRENT

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AH AMPERE HOUR

AHJ AUTHORITY HAVING JURISDICTION

AIC AMPERE INTERRUPTING CAPACITY

ALT ALTERNATE

AMB OR A AMBIENT

AMP AMPERE

ARCH ARCHITECT

ASC AMPS SHORT CIRCUIT

AT AMPERE TRIP

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AV AUDIO VISUAL

HCM HORIZONTAL CABLE MANAGER

HID HIGH INTENSITY DISCHARGE

HOA HAND-OFF-AUTOMATIC

HP HORSEPOWER

HT HEIGHT

HZ HERTZ

BAT BATTERY

BC BARE COPPER

BD BOARD

BFF BELOW FINISH FLOOR

BIL BASIC INSULATION LEVEL

BLDG BUILDING

BLK BLOCK

BPIP BOILER PLANT

INSTRUMENTATION PANEL

BRKR BREAKER

BYP BY PASS

DETAIL REFERENCE

SECTION CUT DESIGNATION

EP-101

EP-101

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. AR12100034 EXP. 12/31/2021

MECH ENGR REG. NO. PE12100220 EXP. 7/31/2022

ELEC ENGR REG. NO. PE12100195 EXP. 7/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATIONS

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSCIAL SECURITY

FORCE PROTECT

3210 GULF BLVD, UNIT 304

BELLEAIR BEACH, FL 33786

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

TECHNOLOGY LEGEND AND

ABBREVIATIONS

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

610A4-21-701

VANIHCS

T-000

No. REVISION DESCRIPTION DATE

11/12/2021 WAMAJS

2121 LAKE AVE,

FORT WAYNE, IN 46805

69 119Willam A. McClendon - 11/12/2021

SCALE: NOT TO SCALE (NTS)

D O

W N

BELOW GRADE - OPEN AIR

D O

W N

BELOW GRADE - OPEN AIR "WINDOW WELL" & H.V.A.C. EQUIPMENT

BELOW GRADE - OPEN AIR "WINDOW WELL"

U P

L A K E A V E N U E

R A

N D

A L L I A

D R

I V E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

C

ITY B

U S S

TO

P

W

GTE

BUILDING

Building 5 Building 6

Building 10

B uilding 7

B uilding 3

BUILDING - 2

BUILDING - 1

Ambulatory Care Addition

(1-Story)

Building 16

Building 4

T1 T2

'U pper'

S

ER

V

IC

E PIT

'D rive'

'Low er'

S

ER

V

IC

E PIT

'D rive'

D O

W N

D O W

N

D O

W N

VERMONT

AVENUE

NEVADA

AVENUE

H

W

H

H

W

W W

T T T T

H

W

H

S

IG

N S

TR

U C

TU

R E

VA-Medical Center Ft. Wayne, IN

17 (MRI)

BUILDING - 1

(5-Stories)

T3

D O

W N

B U

ILD

IN

G

- T6

B U

ILD

IN

G

- T5

B U

ILD

IN

G

- T4 D

O W

N

D O

W N

D O

W N

D O

W N

D O

W N

D O

W N

D O

W N

S

IG

N S

TR

U C

TU

R E

S

IG

N S

TR

U C

TU

R E

Redundant/Diverse Fiber Optic Cable Pathways

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

PR

O

PER

TY LIN

E

To C arew

S t

PROPERTY LINE

PROPERTY LINEPROPERTY LINE

FIB

ER

PA

TH

W A Y B

-1 (N

FIB

ER

PA

TH

W A Y B

-1 (N

FIBER PATHWAY B-1 (N)

FIBER PATHWAY A-1 (N)

FIBER PATHWAY A-1 (N)

FIBER PATHWAY A-1 (E)

FIBER

PATH

W

AY B-2 (N

FI

BE

R

PA

TH

W

AY

A

-1 (E

FIB

ER

PA

TH

W A Y B

-2 (E)

FIBER PATHWAY A-1 (N)

FIBER PATHWAY B-2 (N)

FIBER PATHWAY A-2 (N)

FI

BE

R

PA

TH

W

AY

A

-2 (N

(1) NEMA 3R PULL BOX MOUNTED

ON OUTSIDE WALL HERE - TURN

CONDUITS UP AND STUB INTO PULL BOX

APPROXIMATE CABLE FOOTAGES FROM OUTSIDE OF BUILDING 1

CABLE PATHWAY "A-1"

BUILDING 3 - 360'

BUILDING 5 - 900'

BUILDING 6 - 700'

BUILDING T-4 - 510'

BUILDING T-5 - 570'

BUILDING T-6 - 630'

BUILDING 2 - 350'

BUILDING 4 - 300'

CABLE PATHWAY "B-1"

BUILDING 3 - 550'

BUILDING 5 - 750'

BUILDING 6 - 730'

BUILDING T-6 - 600'

CABLE PATHWAY "B-2"

BUILDING 4 - 650'

BUILDING T-4 - 700 '

BUILDING T-5 - 620'

(1) NEMA-3R PULL BOX

MOUNTED ON OUTSIDE

FIB

ER

PA

TH

W A Y B

-1 (N

FIB

ER

PA

TH

W A Y B

-2 (N

R O

U

TE C

O N

D U

ITS

U

N D

ER

PA

R K

IN

G

LO

T S

PEED

B U

M

PS

IN

TH

IS

A

R

EA

HERE - TURN CONDUITS

UP & STUB INTO PULL BOX

FIB

ER

PA

TH

W A Y A

-1 (N

FIB

ER

PA

TH

W A Y B

-2 (E)

FIBER PATHWAY B-2 (N)

EXISTING TUNNEL

CABLE PATHWAY "A-2"

BUILDING 2 - 150'

FIBER PATHWAY B-1 (N)

FIBER PATH

W

AY A-1 (E)

FIB

ER

PA

TH

W A Y A

-1 (N

(1) NEMA-3R PULL BOX

MOUNTED ON OUTSIDE

HERE - TURN CONDUITS

UP & STUB INTO PULL BOX

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. AR12100034 EXP. 12/31/2021

MECH ENGR REG. NO. PE12100220 EXP. 7/31/2022

ELEC ENGR REG. NO. PE12100195 EXP. 7/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATIONS

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSCIAL SECURITY

FORCE PROTECT

3210 GULF BLVD, UNIT 304

BELLEAIR BEACH, FL 33786

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

TECHNOLOGY SITE PLAN

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

610A4-21-701

VANIHCS

TS101

No. REVISION DESCRIPTION DATE

N

SCALE: NTS1 TECHNOLOGY SITE PLAN

DIFFERENTIATE IT AS THE IT SYSTEM CABLING. SEE SPCIFICATIONS

1. ALL FIBER OPTIC CABLE SHALL BE AMORED, WITH A GREEN JACKET TO

2. ALL FIBER PATCH PANEL ENCLOSURES SHALL BE SIZED FOR 50% SPARE CAPACITY

OUTSIDE PLANT (OSP) BACKBONE GENERAL NOTES

3. ALL FIBER STRANDS SHALL BE FIELD TERMINATED WITH LC CONNECTORS.

4. ALL NEW FIBER CABLES SHALL BE TERMINATED ONTO NEW FIBER PATCH.

PANEL ENCLOSURES IN EACH BUILDING'S TR AND IN THE NEW SERVER.

ROOM.

5. WHEREVER POSSIBLE, THE NEW FIBER BACKBONE AROUND THE CAMPUS

SHALL USE EXISTING CONDUIT PATHWAYS.

6. AFTER CUTOVER, REMOVE THE OLD FIBER IN ALL UNDERGROUND

PATHWAYS AND ALL ASSOCIATED FIBER PATCH PANEL ENCLOSURES.

HARDWARE AND SUPPORT STRUCTURE FROM THE TR ALL THE WAY BACK

TO BLDG 1, SERVER ROOM. ENSURE THAT ANY CABLING THAT IS FOR

OTHER SYSTEMS IS NOT DISTURBED.

7. CABLE FOOTAGES SHOWN ARE APPROXIMATE. CONTRACTOR TO CONFIRM

LENGTHS BEFORE ORDERING CABLE. INCLUDE LENGTH TO PROVIDE CABLE

SLACK LOOPS AROUND THE INSIDE OF EACH MAINTENANCE & HANDHOLES.

OSP FIBER OPTIC BACKBONE KEYNOTES

8. ALL OUTSIDE PLANT (OSP) WORK SHALL ADHERE TO ANSI/TIA/EIA-758

(CUSTOMER-OWNED OUTSIDE PLANT TELECOMMUNICATIONS CABLING STANDARD)

AND BICSI's CUSTOMER-OWNED OUTSIDE PLANT DESIGN MANUAL (Current Edition).

9. NEW UNDERGROUND CONDUITS (NUC) PASSING BENEATH THE PARKING LOTS,

SUBSEQUENTLY CONCRETE ENCASED. PVC CONDUITS TO BE BURIED 36" TO

TOP OF CONDUIT.

10. NEW UNDERGROUND CONDUITS (NUC) AT ALL OTHER LOCATIONS SHALL BE

SCHEDULE-40 PVC CONDUIT PLACED VIA AN OPEN TRENCH AND SUBSEQUENTLY

CONCRETE ENCASED. PVC CONDUITS TO BE BURIED AT 36" MINIMUM TO TOP OF

CONDUITS.

11. A METALLIC WARNING TAPE SHALL BE PLACED IN THE OPEN TRENCH 12"

BELOW GROUND LEVEL. WARNING TAPE SHOULD NOTE SOMETHING TO THE

EFFECT OF "WARNING: FIBER OPTIC CABLE BELOW".

12. NEW HANDHOLE (NHH) INSTALLED SHALL BE 36"W x 48"L x 48"D, PRECAST

CONCRETE, AS MANUFACTURED BY JENSEN, OLDCASTLE, CONCAST OR

EQUIVALENT.

13. NEW HANDHOLE TO BE EQUIPPED WITH LID, SUMP, PULLING-IN IRONS, GROUND

ROD, BONDING RIBBON, CABLE RACKS & HOOKS.

PROVIDE AND INSTALL (7) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY A-1 REDUNDANT HOMERUNS TO BUILDINGS 2, 3, 5, 6, T-4, T-5 & T-6.

PROVIDE AND INSTALL (3) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY B-1 REDUNDANT HOMERUNS TO BUILDINGS 3, 5 & 6.

PROVIDE AND INSTALL (5) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY B-2 REDUNDANT HOMERUNS TO BUILDINGS 2, 4, T-4, T5 & T-6.

PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY B-2 REDUNDANT HOMERUN TO BUILDING 4.

PROVIDE AND INSTALL (2) 4" 3-CELL FABRIC INNERDUCTS INSIDE ONE (1)

PROVIDE AND INSTALL (4) NEW 4" SCHEDULE-80 RIGID PVC CONDUITS VIA

OPEN TRENCH METHOD, 36" BELOW GROUND LEVEL TO TOP OF CONDUIT.

TO TOP OF CONDUIT.

PROVIDE AND INSTALL (4) NEW 4" SCHEDULE-40 RIGID PVC CONDUITS VIA

OPEN TRENCH METHOD, 36" BELOW GROUND LEVEL TO TOP OF CONDUIT.

EXISTING UNDERGROUND CONDUITS

EXISTING MAINTENANCE HOLE (PREVIOUSLY REFERRED TO AS MANHOLE)

EXISTING IN-GROUND HANDHOLE

NEW IN-GROUND HANDHOLE

PROVIDE AND INSTALL (1) NEW 4" SCHEDULE-40 RIGID PVC CONDUIT VIA

OPEN TRENCH, 36" BELOW GROUND LEVEL TO TOP OF CONDUIT.

PROVIDE AND INSTALL (1) NEW NEMA 3R PULL BOX (18"W x 18"L x 12"D).

PROVIDE AND INSTALL (1) 4" 3-CELL FABRIC INNERDUCT (e.g.: MAXCELL)

EXISTING CONDUIT AND INSIDE ONE (1) NEW 4" PVC CONDUIT (e.g.: MAXCELL)

SHALL BE SCHEDULE-80 RIGID PVC CONDUIT PLACED VIA AN OPEN TRENCH AND

PROVIDE AND INSTALL (6) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY A-1 REDUNDANT HOMERUNS TO BUILDINGS 3, 5, 6, T-4, T-5 & T-6.

PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY A-1 REDUNDANT HOMERUN TO BUILDING 2.

PROVIDE AND INSTALL (1) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY A-2 REDUNDANT HOMERUN TO BUILDING 4.

PROVIDE AND INSTALL (2) NEW 4" SCHEDULE-40 RIGID PVC CONDUITS VIA

OPEN TRENCH METHOD, 36" BELOW GROUND LEVEL TO TOP OF CONDUIT.

11/12/2021 WAM

PROVIDE AND INSTALL (2) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY A-1 REDUNDANT HOMERUNS TO BUILDINGS 5 & 6.

PROVIDE AND INSTALL (3) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY A-1 REDUNDANT HOMERUNS TO BUILDINGS T4, T5 & T6.

PROVIDE AND INSTALL (3) EACH 24-STRAND, INDOOR/OUTDOOR, ARMORED

OS2, SINGLEMODE FIBER OPTIC CABLE (OFCP), WITH A GREEN JACKET.

PATHWAY B-2 REDUNDANT HOMERUNS TO BUILDINGS T4, T5 & T6.

AJS

2121 LAKE AVE,

FORT WAYNE, IN 46805

SERVICE PROVIDER (VERIZON) IN-BOUND 144 STRAND, OS2,

SINGLEMODE FIBER OPTIC CABLE.

ONE (1) NEW 4" SCHEDULE-80 RIGID PVC CONDUIT VIA OPEN

TRENCH, 36" BELOW GROUND LEVEL TO TOP OF CONDUIT.

70 119Willam A. McClendon - 11/12/2021 71 OF 120

PHARMACY

STORAGE

005A

MECH

STORAGE

008B

HAC

006 FOOD

MECH/STORAGE

OFFICE

PANTRY

CANTEEN

STORAGE

008A

DN

FREEZER

F01

OFFICE

OFFICE

REFRIGERATOR

R03

FOOD

STORAGE

REFRIGERATOR

R02

EMS

KITCHEN

UP

REFRIGERATOR

R01

OFFICE

DISHWASHER

MECH

022A

STORAGE

STORAGE

STORAGE

TOILET ELEVATOR

TOILET UP

PHARMACY

UP

MECH

VESTIBULE

025A

STORAGE

STORAGE

STORAGE

STORAGE

STORAGE

017 ELEVATOR

VESTIBULE

FIRE

PROTECTION

ELEVATOR

OXYGEN

STORAGE

MORGUE

BATH

060B

WOMENS

LOCKER

ROOM

UP

STAIR #4

CORRIDOR

TOILET

PHARMACY

STORAGE

WOMENS

TOILET

STORAGE

STORAGE

MENS

TOILET

STAIR 2

UP

WET VAC

HAC

SOILED

UTILITY

MECH

OFFICE

WORKSHOP

044A

TOILET

045A

MECH

MAINTENANCE

MENS

LOCKER

ROOM

LOUNGE

045B

MECH

MECH

BIO MED

OFFICE

ELEC

42A

OFFICE

B601

OFFICE

B602

ELEC

WATER

TREATMENT

049C

CORRIDOR

BCC2

VESTIBULE

BC110

CUBICLE,

CLERIVAL

STAFF

B603

MENS

OFFICE

B603A CONFERENCE

B604

ELECTRICAL

B607

STORAGE

B619

STORAGE

HAC

B618A

MECH

036A STORAGE

(FUTURE

STORAGE

(FUTURE LOGISTICS LOGISTICS

STORAGE

B618B

SCOPE

DECONTAMINATION

B618C

SCOPE

STERILIZATION

B605A

LOUNGE,

STAFF

B608

WOMENS

LOCKER

ROOM

B608B

PURCHASING

B610

LOCKER

ROOM

B608A

OFFICE

(FUTURE

ELEV)

B609

SHELL

SPACE

STAIR9

BCST9

UP

HAC

SOILED

UTILITY

STAIR CORRIDOR

BBC4

MAIL ROOM

049A

BIOMETRICS

(ARMAMENTARIUM

REINTEGRATION)

050 OFFICE

050A

DATA

053A

STORAGE

HAC

UP

CORRIDOR CLOSET

TO OSP REDUNDANT PATHWAY A-1

OSP FIBER CABLES TO BLDG's 2, 3, 5, 6, TO OSP REDUNDANT PATHWAY A-1

OSP FIBER CABLES TO BLDG's 2, 3, 5, 6, T-4, T-5 & T-6.

T-4, T-5 & T-6.

TO 1ST, 2ND, 3RD, 4TH & 5TH FLOOR TR's

ISP FIBER BACKBONE CABLES VERTICAL PATHWAY "B"

TO 1ST, 2ND, 3RD, 4TH & 5TH FLOOR TR's

ISP FIBER BACKBONE CABLES VERTICAL PATHWAY "A"

TO OSP REDUNDANT PATHWAY B-2

OSP FIBER CABLES TO BLDG's 2, 4, T-4, T5 & T6.

TO OSP REDUNDANT PATHWAY A-2

OSP FIBER CABLE TO BLDG 4.

MAIN COMPUTER ROOM/DATA CENTER/SERVER ROOM #057

TR-B606

HAC

063A

063A

LG

D

U A

L IN

V

ER

TER

A

C C O

R N

IN

G

M A S

UP TO 1ST FLOOR (PATHWAY YET TO BE DETERMINED)

ISP FIBER BACKBONE CABLE PATHWAY "B"

TR-63/TCB

LENEL/ALTRONIX RS2 SYSTEM

POWER PANEL

th re e in c h e s o n e fo o t o n e a n d o n e h a lf in c h e s o n e fo o t o n e in c h o n e fo o t th re e q u a rt e rs in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e e ig h th s in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t o n e e ig h th in c h o n e fo o t

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. AR12100034 EXP. 12/31/2021

MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATIONS

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSCIAL SECURITY

FORCE PROTECT

3210 GULF BLVD, UNIT 304

BELLEAIR BEACH, FL 33786

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

A

B

C

D

E

F

STAMP:

Drawing Number

Building Number

BUILDING 1 - BASEMENT

TECHNOLOGY FLOOR PLAN

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

610A4-21-701

VANIHCS

T-100

No. REVISION DESCRIPTION DATE

ISP FIBER OPTIC BACKBONE KEYNOTES:

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE

CABLE TRAY.

NOT TO SCALE (NTS)

B1 - BASEMENT LEVEL - TECHNOLOGY PLAN

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE

CABLE TRAY.

PROVIDE AND INSTALL (7) EACH 24-STRAND, SINGLEMODE (OS2),

ARMORED, FIBER OPTIC CABLES (OFCP), WITH A GREEN JACKET

FOR OSP PATHWAYS A-1 REDUNDANT HOMERUNS TO

BUILDINGS 2, 3, 5, 6, T-4, T-5 & T-6.

PROVIDE AND INSTALL (3) EACH 24-STRAND, SINGLEMODE (OS2),

ARMORED, FIBER OPTIC CABLES (OFCP), WITH A GREEN JACKET

FOR OSP PATHWAYS B-1 REDUNDANT HOMERUNS TO

BUILDINGS 3, 5, & 6.

PROVIDE AND INSTALL (5) EACH 24-STRAND, SINGLEMODE (OS2),

ARMORED, FIBER OPTIC CABLES (OFCP), WITH A GREEN JACKET

FOR OSP PATHWAYS B-2 REDUNDANT HOMERUNS TO

BUILDINGS 2, 4, T-4, T-5 & T-6.

PROVIDE AND INSTALL (1) EACH 24-STRAND, SINGLEMODE (OS2),

ARMORED, FIBER OPTIC CABLES (OFCP), WITH A GREEN JACKET

FOR OSP PATHWAYS A-2 REDUNDANT HOMERUN TO

BUILDING 4.

PROVIDE AND INSTALL (5) EACH 12-STRAND SINGLEMODE (OS2)/

24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC

CABLES, WITH A GREEN JACKET, FOR ISP PATHWAY "A"

REDUNDANT HOMERUNS TO TR's ON THE 1ST, 2ND, 3RD, 4TH & 5TH

FLOORS..

PROVIDE AND INSTALL (6) EACH 12-STRAND SINGLEMODE (OS2)/

24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC

CABLES, WITH A GREEN JACKET, FOR ISP PATHWAY "B"

REDUNDANT HOMERUNS TO TR's ON THE BASEMENT, 1ST, 2ND, 3RD, 4TH & 5TH FLOORS.

PROVIDE AND INSTALL (1) EACH 12-STRAND SINGLEMODE (OS2)/

24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC

CABLE, WITH A GREEN JACKET, FOR ISP PATHWAY "A"

REDUNDANT HOMERUN TO TR-63/TCB.

PROVIDE AND INSTALL (1) EACH 12-STRAND SINGLEMODE (OS2)/

24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC

CABLE, WITH A GREEN JACKET, FOR ISP PATHWAY "B"

REDUNDANT HOMERUN TO TR-63/TCB.

PROVIDE AND INSTALL (1) EACH 12-STRAND SINGLEMODE (OS2)/

24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC

CABLE, WITH A GREEN JACKET, FOR ISP PATHWAY "A"

REDUNDANT HOMERUN TO TR-B606.

PROVIDE AND INSTALL (1) EACH 12-STRAND SINGLEMODE (OS2)/

24-STRAND MULTIMODE (OM4) HYBRID, ARMORED, FIBER OPTIC

CABLE, WITH A GREEN JACKET, FOR ISP PATHWAY "B"

REDUNDANT HOMERUN TO TR-B606.

N

11/12/2021 WAMAJS

2121 LAKE AVE,

FORT WAYNE, IN 46805

11971Willam A. McClendon - 11/12/2021

REFRIGERATOR

MECH

022A

STORAGE

STORAGE

028A

PHARMACY

MECH

029A

LINEN

STORAGE

030B

OFFICE

030C

BREAKROOM

UP

MECH

VESTIBULE

025A

STORAGE

STORAGE

STORAGE

STORAGE

EMS OFFICE

SUPERVISOR

030A

EMS

STORAGE

030D

WOMENS

TOILET

STORAGE

STORAGE

STORAGE

MENS

TOILET

STAIR 2

UP

HAC

SOILED

UTILITY

MECH

UP

MECH

BIO MED

OFFICE

ELEC

MECH

036A

TO 1ST, 2ND, 3RD, 4TH & 5TH FLOOR TR's

ISP FIBER BACKBONE CABLES VERTICAL PATHWAY "A"

2 2

4 2

MATCHLINE

T100-A

T1

-A T1

-D

MATCHLINE

T100-A

M

AT

C H

LI

N

E T1

-B

M

AT

C H

LI

N

E

JH

JH

JH

JH JH

JH

JH

JH

JH

JH

JH

JH

N ot e:

A ll W

AO

C ab le s in a re a T1

-D to b e ro ut ed to , a nd te rm in at ed in T

R -6

3/

TC

B N ot e:

A ll

W

AO

C ab le s in a re a

T1

-A to b e ro ut ed to

, a nd te rm in at ed in

T R

-6 3/

TC

B

(N ot e:

A ll W

AO

C ab le s in a re a T1

-B to b e ro ut ed to , a nd te rm in at ed in T

R -0

/T

C B)

(Note: All WAO Cables in area T100-A to be routed to, and terminated in TR-63/TCB)

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. AR12100034 EXP. 12/31/2021

MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATIONS

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSCIAL SECURITY

FORCE PROTECT

3210 GULF BLVD, UNIT 304

BELLEAIR BEACH, FL 33786

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

STAMP:

Drawing Number

Building Number

BUILDING 1 - BASEMENT

TECHNOLOGY FLOOR PLAN - AREA A

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

610A4-21-701

VANIHCS

T100A

No. REVISION DESCRIPTION DATE

1 B1 - BASEMENT LEVEL - TECHNOLOGY PLAN

N

11/12/2021 WAM

SCALE: 1/8" = 1'0"

AJS

2121 LAKE AVE,

FORT WAYNE, IN 46805

11972

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

TECHNOLOGY KEYNOTES:

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'A' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'B' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 12"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA

OUTLET (WAO) STATION CABLES.

tiles and the floor above. If in the event that the cable tray cannot be installed , a J-Hook pathway shall be established to support the Category 6A station cables.

Note: Cable Tray Installation is contingent upon the amount of congestion evident in the space between the drop ceiling grid/

INTERSECTING CABLE TRAYS WILL BE SEPARATED VERTICALLY, SO AS TO AVOID CABLE ROUTING CONFLICTS

BETWEEN FIBER BACKBONE CABLES AND UTP STATION CABLES.

LEGEND:

VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101

FOR MORE DETAILS)

VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101

FOR MORE DETAILS)

ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS

(IF POSSIBLE) IN GENERAL PATHWAYS.

ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS

SECONDARY BONDING BUSBAR.

AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES

WHERE CABLING WAS REMOVED.

AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE

CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.

A.

B.

C.

D.

E.

F.

G.

H.

CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING

ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE

DROPS.

ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO

THE NEW CABLING.

EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.

EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.

LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN

OLTS AND AN OTDR PER THE TIER 2 STANDARD.

PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE

MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)

NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE

PATHWAYS.

I. EXISTING CONDUITS TO REMAIN.

J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.

K.

L.

M.

N.

PHASE 1 - INSTALL APPROXIMATELY (0) NEW CATEGORY 6A DATA CABLES ON THE BASEMENT LEVEL TO A MIXTURE OF

(0) DUAL AND QUAD NEW WORK AREA OUTLET LOCATIONS.

O.

W

WAP

WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.

(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B

(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2).

INSTALLATION..

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

GENERAL NOTES:

PROVIDE AND INSTALL 18"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA

OUTLET (WAO) STATION CABLES.

PROVIDE AND INSTALL J-HOOK PATHWAYS TO SUPPORT CATEGORY 6A STATION CABLES FROM WAO TO MAIN CABLE TRAY OR MAIN J-HOOK PATHWAY BACK TO THE ASSOCIATED TR (TYPICAL). INSTALL AT 5' (MAXIMUM) .

INTERVALS O.C. (NOTE: J-HOOK PATHWAYS DEPICTED ARE JUST A FEW EXAMPLES. ALL STATION CABLING MUST BE SUPPORTED BY J-HOOK PATHWAYS THAT ARE PARALLEL AND PERPENDICULAR TO BUILDING LINES.)

= 4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2)

CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)

X

X = PHASE 1 - THESE NEW WORK AREA OUTLET LOCATIONS (NWAO's) ARE TO BE INSTALLED IN PHASE 1.

= PHASE 2 - THESE EXISTING WORK AREA OUTLET LOCATIONS (EWAO's) ARE TO BE INSTALLED IN PHASE 2.

PHASE 2 - INSTALL APPROXIMATELY (160) NEW CATEGORY 6A DATA CABLES ON THE BASEMENT LEVEL TO A MIXTURE

OF (76) DUAL AND QUAD EXISTING WORK AREA OUTLET LOCATIONS.

P.

Willam A. McClendon - 11/12/2021 73 OF 120

PHARMACY

STORAGE

005A

MECH

STORAGE

008B

HAC

006 FOOD

MECH/STORAGE

OFFICE

PANTRY

CANTEEN

STORAGE

008A

DN

FREEZER

F01

OFFICE

OFFICE

REFRIGERATOR

R03

FOOD

STORAGE

REFRIGERATOR

R02

EMS

KITCHEN

UP

REFRIGERATOR

R01

OFFICE

DISHWASHER

MECH

022A

STORAGE

STORAGE

STORAGE

STORAGE

028A

TOILET ELEVATOR

TOILET UP

PHARMACY

UP

TO OSP REDUNDANT PATHWAY A-1

OSP FIBER CABLES TO BLDG's 2, 3, 5, 6, TO OSP REDUNDANT PATHWAY A-1

OSP FIBER CABLES TO BLDG's 2, 3, 5, 6, T-4, T-5 & T-6.

T-4, T-5 & T-6.

(Note: All WAO Cables in area T100-C to be routed to, and terminated in TR-B606)

M

AT

C H

LI

N

E T1

-B

M

ATC

H

LIN

E T100-B

MATCHLINE

T100-A

M

AT

C H

LI

N

E T1

-B

MATCHLINE

T100-C

M

ATC

H

LIN

E T100-B

MATCHLINE

T-100-D T-100-B

JHJH

JH

JH

JH

JH

JH

JH

POWER PANEL

(N ote: All W

AO

C ables in area T100-B to be routed to, and term inated in TR

-063/TC

B)

(N ot e:

A ll W

AO

C ab le s in a re a T1

-B to b e ro ut ed to , a nd te rm in at ed in T

R -0

/T

C B)

(Note: All WAO Cables in area T100-A to be routed to, and terminated in TR-63/TCB)

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. AR12100034 EXP. 12/31/2021

MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATIONS

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSCIAL SECURITY

FORCE PROTECT

3210 GULF BLVD, UNIT 304

BELLEAIR BEACH, FL 33786

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

STAMP:

Drawing Number

Building Number

BUILDING 1 - BASEMENT

TECHNOLOGY FLOOR PLAN - AREA B

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

610A4-21-701

VANIHCS

T100B

No. REVISION DESCRIPTION DATE

1 B1 - BASEMENT LEVEL - TECHNOLOGY PLAN

N

11/12/2021 WAM

SCALE: 1/8" = 1'0"

AJS

2121 LAKE AVE,

FORT WAYNE, IN 46805

11973

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

TECHNOLOGY KEYNOTES:

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'A' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'B' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 12"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA

OUTLET (WAO) STATION CABLES.

tiles and the floor above. If in the event that the cable tray cannot be installed , a J-Hook pathway shall be established to support the Category 6A station cables.

Note: Cable Tray Installation is contingent upon the amount of congestion evident in the space between the drop ceiling grid/

INTERSECTING CABLE TRAYS WILL BE SEPARATED VERTICALLY, SO AS TO AVOID CABLE ROUTING CONFLICTS

BETWEEN FIBER BACKBONE CABLES AND UTP STATION CABLES.

LEGEND:

VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101

FOR MORE DETAILS)

VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101

FOR MORE DETAILS)

ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS

(IF POSSIBLE) IN GENERAL PATHWAYS.

ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS

SECONDARY BONDING BUSBAR.

AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES

WHERE CABLING WAS REMOVED.

AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE

CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.

A.

B.

C.

D.

E.

F.

G.

H.

CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING

ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE

DROPS.

ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO

THE NEW CABLING.

EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.

EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.

LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN

OLTS AND AN OTDR PER THE TIER 2 STANDARD.

PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE

MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)

NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE

PATHWAYS.

I. EXISTING CONDUITS TO REMAIN.

J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.

K.

L.

M.

N.

PHASE 1 - INSTALL APPROXIMATELY (0) NEW CATEGORY 6A DATA CABLES ON THE BASEMENT LEVEL TO A MIXTURE OF

(0) DUAL AND QUAD NEW WORK AREA OUTLET LOCATIONS.

O.

W

WAP

WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.

(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B

(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2).

INSTALLATION..

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

GENERAL NOTES:

PROVIDE AND INSTALL 18"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA

OUTLET (WAO) STATION CABLES.

PROVIDE AND INSTALL J-HOOK PATHWAYS TO SUPPORT CATEGORY 6A STATION CABLES FROM WAO TO MAIN CABLE TRAY OR MAIN J-HOOK PATHWAY BACK TO THE ASSOCIATED TR (TYPICAL). INSTALL AT 5' (MAXIMUM) .

INTERVALS O.C. (NOTE: J-HOOK PATHWAYS DEPICTED ARE JUST A FEW EXAMPLES. ALL STATION CABLING MUST BE SUPPORTED BY J-HOOK PATHWAYS THAT ARE PARALLEL AND PERPENDICULAR TO BUILDING LINES.)

= 4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2)

CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)

X

X = PHASE 1 - THESE NEW WORK AREA OUTLET LOCATIONS (NWAO's) ARE TO BE INSTALLED IN PHASE 1.

= PHASE 2 - THESE EXISTING WORK AREA OUTLET LOCATIONS (EWAO's) ARE TO BE INSTALLED IN PHASE 2.

PHASE 2 - INSTALL APPROXIMATELY (160) NEW CATEGORY 6A DATA CABLES ON THE BASEMENT LEVEL TO A MIXTURE

OF (76) DUAL AND QUAD EXISTING WORK AREA OUTLET LOCATIONS.

Willam A. McClendon - 11/12/2021 74 OF 120

UP

OXYGEN

STORAGE

MORGUE

BATH

060B

WOMENS

LOCKER

ROOM

UP

STAIR #4

CORRIDOR

TOILET

PHARMACY

STORAGE

WET VAC

MECH

MENS

LOCKER

ROOM

LOUNGE

045B

MECH

OFFICE

B601

OFFICE

B602

WATER

TREATMENT

049C

CORRIDOR

BCC2

VESTIBULE

BC110

CUBICLE,

CLERIVAL

STAFF

B603

MENS

OFFICE

B603A CONFERENCE

B604

ELECTRICAL

B607

STORAGE

B619

STORAGE

HAC

B618A

AUTOMATIC

CART WASH

B618E

DECONTAMINATION

B618

HAC

CORRIDOR

BCC1

TEMP

STORAGE

(FUTURE

MECH)

B617

LOUNGE

B616 SPS

ASSITANT

OFFICE

B616C

B605C

OFFICE

B613

STERILE/NON-STERILE

STORAGE

B615

CART PREP

B605

STORAGE

(FUTURE

DUMBWAITER)

B605D

STORAGE

(FUTURE

EQUIP.

ROOM)

B615A

CORRIDOR

BCC3

HAC

B612

LOGISTICS

DIRECTOR

B611B

LOGISTICS

MANAGEMENT

B611

LOGISTICS

SUPERVISOR

B611A

STORAGE

B618B

SCOPE

DECONTAMINATION

B618C

SCOPE

STERILIZATION

B605A

LOUNGE,

STAFF

B608

WOMENS

LOCKER

ROOM

B608B

PURCHASING

B610

LOCKER

ROOM

B608A

OFFICE

(FUTURE

ELEV)

B609

SHELL

SPACE

STAIR9

BCST9

UP

HAC

SOILED

UTILITY

STAIR CORRIDOR

BBC4

MAIL ROOM

049A

BIOMETRICS

(ARMAMENTARIUM

REINTEGRATION)

050 OFFICE

050A

053A

STORAGE

HAC

UP

CORRIDOR CLOSET

PREP/ASSEMBLY

B605B

WOMENS

LOCKER

ROOM

B616A

UP

STAIR 10

BCST10

STERILIZER

ACCESS

B614A

MENS

LOCKER

ROOM

B616B

WAREHOUSE

B614

TO 1ST, 2ND, 3RD, 4TH & 5TH FLOOR TR's

ISP FIBER BACKBONE CABLES VERTICAL PATHWAY "B"

TO OSP REDUNDANT PATHWAY B-2

TO OSP REDUNDANT PATHWAY A-2

OSP FIBER CABLE TO BLDG 4.

2 2

2 2 2

2 2

MATCHLINE

(Note: All WAO Cables in area T100-C to be routed to, and terminated in TR-B606)

M

AT

C H

LI

N

E T1

-C

MATCHLINE

T100-C

M

ATC

H

LIN

E T100-B

T1

-D

JH

JH

JH

JH

JH

JH

JH

JHJHJH

JH

JH

JH

JH

JH

JHJH

MAIN COMPUTER ROOM/DATA CENTER/SERVER ROOM

Scale: 1" = 1'

TR-B606

T100-C

(N ot e:

A ll W

AO

C ab le s in a re a T1

-C to b e ro ut ed to , a nd te rm in at ed in T

R -B

6)

(N ot e:

A ll W

AO

C ab le s in a re a T1

-D to b e ro ut ed to , a nd te rm in at ed in T

R -6

3/

TC

B)

A

B

C

D

E

F

Veterans Health

Administration

VA FORM 08-6231

Drawing Title Project Title

Location

Date Checked Drawn

Project NumberCONSULTANTS:

Drawing # OF

VA Health Care System Approval:

ARCHITECT:

SPUR DESIGN, LLC

312 SW 25TH STREET

Oklahoma City, OK 73109

(405) 842-6100

ARCH REG. NO. AR12100034 EXP. 12/31/2021

MECH ENGR REG. NO. PE12100220 EXP. 07/31/2022

ELEC ENGR REG. NO. PE12100195 EXP. 07/31/2022

CIVIL ENGINEER

OLSSON

550 ST LOUIS ST,

SPRINGFIELD, MO 65806

(417) 885-1736

MECH / ELEC / PLUMB / TECH ENGINEER

SPUR DESIGN

11020 KING STREET, SUITE 350

OVERLAND PARK, KS 66210

(913) 369-7200

FIRE PROTECTION ENGINEER

POOLE FIRE PROTECTION, INC.

19910 WEST 161ST STREET

OLATHE, KANSAS 66062

(913) 829-8690

FULLY SPRINKLERED

INDUSTRIAL HYGENIST

RIVERFRONT SAFETY & HEALTH

1139 OLIVE ST, SUITE 300

ST. LOUIS, MO 63101

(713) 864-2900

TELECOMMUNICATIONS

ASPEN ENGINEERING & CONTRACTING

7 KIJI-DAVA CIRCLE, SUITE A

PRESCOTT, AZ 85712

(928) 774-0992

PHYSCIAL SECURITY

FORCE PROTECT

3210 GULF BLVD, UNIT 304

BELLEAIR BEACH, FL 33786

(502) 836-4232

1 2 3 4 5 6 7 8 9

1 2 3 4 5 6 7 8 9

STAMP:

Drawing Number

Building Number

BUILDING 1 - BASEMENT

TECHNOLOGY FLOOR PLAN - AREA C

BID DOCUMENTS

EHRM INFRASTRUCTURE

UPGRADES FORT WAYNE,

INDIANA

610A4-21-701

VANIHCS

T100C

No. REVISION DESCRIPTION DATE

1 B1 - BASEMENT LEVEL - TECHNOLOGY PLAN

N

11/122021 WAM

SCALE: 1/8" = 1'0"

AJS

2121 LAKE AVE,

FORT WAYNE, IN 46805

11974

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 4"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

TECHNOLOGY KEYNOTES:

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'A' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 2"W x 2"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT REDUNDANT FIBER OPTIC

BACKBONE 'B' CABLE. (SEE PLAN SHEET T-101 FOR MORE DETAILS)

PROVIDE AND INSTALL 12"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA

OUTLET (WAO) STATION CABLES.

tiles and the floor above. If in the event that the cable tray cannot be installed , a J-Hook pathway shall be established to support the Category 6A station cables.

Note: Cable Tray Installation is contingent upon the amount of congestion evident in the space between the drop ceiling grid/

INTERSECTING CABLE TRAYS WILL BE SEPARATED VERTICALLY, SO AS TO AVOID CABLE ROUTING CONFLICTS

BETWEEN FIBER BACKBONE CABLES AND UTP STATION CABLES.

LEGEND:

VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'A' CABLES. (SEE PLAN SHEET T-101

FOR MORE DETAILS)

VERTICAL PATHWAY FOR REDUNDANT-DIVERSE FIBER OPTIC BACKBONE 'B' CABLES. (SEE PLAN SHEET T-101

FOR MORE DETAILS)

ALL CATEGORY 6A STATION CABLING SHALL BE SUPPORTED USING A COMBINATION OF J-HOOKS AND CABLE TRAYS

(IF POSSIBLE) IN GENERAL PATHWAYS.

ENSURE THAT ALL GROUNDING AND BONDING IS COMPLETE. TWO SCREW BONDING LUGS NEED TO BE INSTALLED TO BOND ALL METALLIC COMPONENTS OF THE RACK AND CABLE TRAY SYSTEM, TO THE TELECOMMUNICATIONS

SECONDARY BONDING BUSBAR.

AFTER CUT-OVER TO THE NEW CABLING, DEMOLISH ALL OLD DATA AND TELEPHONE CABLING ALL THE WAY TO THE STATION END. ENSURE THAT ANY CABLES IN THE CEILING AREAS THAT ARE FOR SYSTEMS OTHER THAN THE IT DATA AND TELEPHONE, ARE NOT DISTURBED. BLANK OFF ANY UNUSED OLD DATA LOCATIONS. DEMOLISH ALL OLD PATCH PANELS AND ASSOCIATED HARDWARE. ALL OTHER ANCILLARY RACK-MOUNTED EQUIPMENT, NOT RELATED TO IT DATA AND TELEPHONE, TO BE RELOCATED TO A NEW RACK BY OIT PERSONNEL. FIRE-STOP ALL EXISTING SLEEVES

WHERE CABLING WAS REMOVED.

AFTER CUT-OVER, REMOVE ALL OLD IT FIBER OPTIC CABLING FROM THE TR ALL THE WAY BACK TO THE SERVER ROOM. DEMOLISH ALL ASSOCIATED HARDWARE AND TERMINATION EQUIPMENT. ENSURE THAT ANY CABLING IN THE

CEILING AREA THAT IS FOR OTHER SYSTEMS, IS NOT DISTURBED.

A.

B.

C.

D.

E.

F.

G.

H.

CONTRACTOR SHALL INCLUDE AN ADDITIONAL 10% OF CABLE DROPS IN THEIR BID FOR ADDS FOUND DURING

ADDITIONAL PATCH PANEL CAPACITY SHALL BE PROVIDED TO ACCOUNT FOR 15% GROWTH OF ADDITIONAL CABLE

DROPS.

ALL EXISTING DATA CABLES AND CIRCUITS MUST REMAIN IN PLACE AND OPERATIONAL UNTIL FINAL CUT-OVER TO

THE NEW CABLING.

EACH NEW WORK AREA OUTLET (WAO) LOCATION WILL CONSIST OF TWO OR FOUR CAT6A CABLES AS SHOWN ON THE PLANS. EACH CABLE WILL BE TERMINATED ON A 48-PORT CAT6A PATCH PANEL IN IT'S DESIGNATED TR.

EXISTING WAO LOCATIONS SHALL BE RE-USED WHEREVER POSSIBLE.

LABEL FIBER CABLE GOING INTO EACH FIBER PATCH PANEL. ALL FIBER STRANDS WILL BE TESTED UTILIZING AN

OLTS AND AN OTDR PER THE TIER 2 STANDARD.

PROVIDE (1) EACH SMALL DIAMETER CAT6A PATCH CORD FOR EACH NEW DATA PORT. PROVIDE VARIOUS LENGTHS AS REQUIRED FOR A NEAT AND ORDERLY INSTALLATION, UTILIZING THE VERTICAL AND HORIZONTAL WIRE

MANAGERS AS APPLICABLE. (SEE SPECIFICATIONS)

NEW FIRE-RATED SLEEVES SHALL BE INSTALLED EXITING THE TR AND IN ALL FIRE-RATED WALLS ALONG THE CABLE

PATHWAYS.

I. EXISTING CONDUITS TO REMAIN.

J. EXISTING DATA RACK/RACKS TO REMAIN UNTIL AFTER CUT-OVER.

K.

L.

M.

N.

PHASE 1 - INSTALL APPROXIMATELY (0) NEW CATEGORY 6A DATA CABLES ON THE BASEMENT LEVEL TO A MIXTURE OF

(0) DUAL AND QUAD NEW WORK AREA OUTLET LOCATIONS.

O.

W

WAP

WALL PHONE OUTLET CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B.

(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

WIRELESS ACCESS POINT CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME TO BE T568B

(EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2).

INSTALLATION..

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (1) CATEGORY 6A UTP CABLE TERMINATED ONTO (1) CATEGORY 6A RJ-45 TYPE (8P-8C) JACK. UTP CABLE JACKET COLORE TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (EXISTING WAO LOCATION TO BE INSTALLED IN PHASE 2)

GENERAL NOTES:

PROVIDE AND INSTALL 18"W x 4"D WIRE BASKET TYPE CABLE TRAY TO SUPPORT CATEGORY 6A UTP WORK AREA

OUTLET (WAO) STATION CABLES.

PROVIDE AND INSTALL J-HOOK PATHWAYS TO SUPPORT CATEGORY 6A STATION CABLES FROM WAO TO MAIN CABLE TRAY OR MAIN J-HOOK PATHWAY BACK TO THE ASSOCIATED TR (TYPICAL). INSTALL AT 5' (MAXIMUM) .

INTERVALS O.C. (NOTE: J-HOOK PATHWAYS DEPICTED ARE JUST A FEW EXAMPLES. ALL STATION CABLING MUST BE SUPPORTED BY J-HOOK PATHWAYS THAT ARE PARALLEL AND PERPENDICULAR TO BUILDING LINES.)

= 4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (2) CATEGORY 6A UTP CABLES TERMINATED ONTO (2)

CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)

4-PORT WORK AREA OUTLET FACEPLATE CONTAINING (4) CATEGORY 6A UTP CABLES TERMINATED ONTO (4) CATEGORY 6A RJ-45 TYPE (8P-8C) JACKS. UTP CABLE JACKET COLOR TO BE BLUE. TERMINATION SCHEME

TO BE T568B. (NEW WAO LOCATION TO BE INSTALLED IN PHASE 1)

X

X = PHASE 1 - THESE NEW WORK AREA OUTLET LOCATIONS (NWAO's) ARE TO BE INSTALLED IN PHASE 1.

= PHASE 2 - THESE EXISTING WORK AREA OUTLET LOCATIONS (EWAO's) ARE TO BE INSTALLED IN PHASE 2.

PHASE 2 - INSTALL APPROXIMATELY (160) NEW CATEGORY 6A DATA CABLES ON THE BASEMENT LEVEL TO A MIXTURE

OF (76) DUAL AND QUAD EXISTING WORK AREA OUTLET LOCATIONS.

P.

Willam A. McClendon - 11/12/2021

MECH

022A

STORAGE

STORAGE

STORAGE

TOILET ELEVATOR

TOILET UP

PHARMACY

UP

MECH

VESTIBULE

025A

STORAGE

STORAGE

STORAGE

STORAGE

STORAGE

017 ELEVATOR

VESTIBULE

FIRE

PROTECTION

ELEVATOR

OXYGEN

STORAGE

MORGUE

BATH

060B

WOMENS

LOCKER

ROOM

WOMENS

TOILET

STORAG…