Attachment 7 - DSCC Excavation Permit.pdf
PDF 958 KB Posted
- Attached to
- CSC-20019; DSCC BLDG 27 Boiler Conversion Federal contract opportunity
- Solicitation number
- SP4702-21-R-0018
- Issued by
- Defense Logistics Agency
About this file
This solicitation is for a full conversion of the boiler system at Building 27 of the Defense Supply Center in Columbus, Ohio. The existing steam boiler system will be removed, demolition and repair work completed, and a new hot water boiler system installed. The procurement is a 100% small business set-aside between $1 million to $5 million as a firm fixed-price contract. Proposals are due by July 15, 2021, and award will be made to the lowest-priced technically acceptable offer with acceptable past performance. A mandatory site visit is scheduled for June 30, 2021, and questions are due by July 6, 2021. Responses must include forms SF1442, a bid form, bid bond, past performance, and a contract management plan with resumes. The Defense Logistics Agency is the contracting agency.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| SF30_SP470221R00180001.pdf | ||
| FinalBldg27ACMUpdate.pdf | ||
| Updated Attachment 10 - Bid Form.pdf | ||
| Attachment 12 - Drawings 4-582.pdf | ||
| RFIs for SP4702-21-R-0018.pdf | ||
| Final Bldg 27 ACM Survey.pdf | ||
| Updated Solicitation SP4702-21-R-0018.pdf | ||
| Updated Attachment 2 - SOW and Complete Specs.pdf | ||
| Solicitation SP4702-21-R-0018.pdf | ||
| Attachment 1 - Clauses and Evaluation Criteria.pdf | ||
| Attachment 3 - Drawing Package.pdf | ||
| Attachment 5 - Wage Rate Determination OH20210078.pdf | ||
| Attachment 10 - Bid Form.pdf | ||
| Attachment 4 - CAC Procedures.pdf | ||
| Attachment 2 - SOW and Complete Specs.pdf | ||
| Attachment 6 - ENG Form 93.pdf | ||
| Attachment 8 - ENG Form 4025-R.pdf | ||
| Attachment 9 - Contractor Access Badge Request Form.xlsx | XLSX spreadsheet | |
| Attachment 11 - Submittal Register.xlsx | XLSX spreadsheet |
Show all 19
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DEFENSE SUPPLY CENTER COLUMBUS EXCAVATION PERMIT
PERMIT NUMBER
In case of an emergency, dial 911 from a DSCC phone or call the DSCC Fire Department at (614) 692-2111.
PROJECT NAME DATE
PROJECT START DATE PROJECT END DATE DURATION
PRIME CONTRACTOR SUB-CONTRACTOR / EXCAVATION CONTRACTOR
CONTRACTOR REPRESENTATIVE CONTRACTOR REPRESENTATIVE PHONE NO.
DSCC FACILITIES REPRESENTATIVE DSCC FACILITIES REPRESENTATIVE PHONE NO.
DESCRIPTION OF WORK AND LOCATION
Excavation by Contractor include applicable drawings.
Excavation by Government
Excavation / Trench Depth: Less than 5 ft. Greater than 5 ft. Greater than 20 ft.
Note: If excavation depth is greater than 5 ft., a soil analysis will be required to determine the appropriate Protective System that will be utilized. A Competent Person shall be on site during trenching and/or excavating activities.
SOIL ANALYSIS CONTRACTOR COMPETENT PERSON SOIL ANALYSIS CONTRACTOR PHONE NO.
SOIL ANALYSIS METHOD UTILIZED NAME OF PROFESSIONAL ENGINEER (if excavation is greater than 20 ft.)
SOIL ANALYSIS RESULTS PROVIDED TO FACILITIES: Yes No
CONTRACTOR REVIEWED UTILITY DRAWINGS: Yes No
UNDERGROUND UTILITIES IDENTIFIED: Yes No If no, provide explanation:
INSTRUMENTS UTILIZED TO IDENTIFY UNDERGROUND UTILITIES: Passive or Active Electromagnetic RF Detector
Ground Penetrating Radar
Other (provide type):
UTILITIES CHECKED BELOW WERE IDENTIFIED, AND MARKED ACCORDINGLY AT THE WORK LOCATION
Electrical Water Sewer Compressed Gas Communications* Stormwater
IS PROTECTIVESHORING SYSTEM REQUIRED: Yes No
Shoring Shielding Benching Sloping Not Applicable
REVIEWED BY CONCURRENCES
PRINT SIGN DATE
CONTRACTOR (Required) (Company Name)
SUBMITTED BY
DSCC FACILITIES REPRESENTATIVE
PROFESSIONAL ENGINEER DATE
(if excavation is greater than 20ft.)
COMPETENT PERSON DATE
NOTES: PERMIT SHALL BE KEPT AT THE WORK LOCATION AT ALL TIMES
* If Communications utilities are present Defense Information Systems Agency (DISA) may require 30 Days Advanced Notice prior to excavation c011169 Text Box Attachment 7; SP4702-21-R-0018
| PERMIT NUMBER: |
| PROJECT NAME: |
| DATE: |
| PROJECT START DATE: |
| PROJECT END DATE: |
| DURATION: |
| PRIME CONTRACTOR: |
| SUB-CONTRACTOR / EXCAVATION CONTRACTOR: |
| CONTRACTOR REPRESENTATIVE: |
| CONTRACTOR REPRESENTATIVE PHONE NO.: |
| JPL FACILITIES REPRESENTATIVE: |
| JPL FACILITIES REPRESENTATIVE PHONE NO.: |
| Construction Project include applicable drawings: Off |
| Construction Project include applicable drawings: Off |
| Excavation / Trench Depth: |
| Less than 5 ft: Off |
| Greater than 5 ft: Off |
| Greater than 5 ft: Off |
| SOIL ANALYSIS CONTRACTOR: |
| SOIL ANALYSIS CONTRACTOR PHONE NO.: |
| SOIL ANALYSIS METHOD UTILIZED: |
| undefined: Off |
| undefined: Off |
| CONTRACTOR REVIEWED UTILITY DRAWINGS: Yes No: |
| undefined: Off |
| undefined: Off |
| Yes: Off |
| No If no, provide explanation: Off |
| Passive or Active Electromagnetic RF Detector: Off |
| Ground Penetrating Radar: Off |
| undefined: Off |
| Other (provide type: |
| Electrical: Off |
| Water: Off |
| Sewer: Off |
| Compressed Gas: Off |
| Communications: Off |
| Stormwater: Off |
| Yes: Off |
| No If yes, select type below: Off |
| Shoring: Off |
| Shielding: Off |
| Benching: Off |
| Sloping: Off |
| Not Applicable: Off |
| CONTRACTOR (Required) (Company Name): |
| PROTECTIVE SERVICES (as applicable) DATE: |
| SUBMITTED BY: |
| TRANSPORTATION (as applicable) DATE: |
| FACILITIES (Required): |
File details come from the government source that posted it. Updated .