Attachment 6 - Geo Infiltration Testing - 2019-12-05 - FNL.pdf
PDF 3 MB Posted
- Solicitation number
- 36E77620R0042
About this file
This geotechnical engineering letter report summarizes infiltration testing conducted for a stormwater detention and treatment facility project at the White City VA in Oregon. The letter describes field exploration including two test pits excavated to depths of 10 feet below ground surface. Both test pits encountered a hard clay fill layer underlain by a cemented silt, sand and gravel hardpan layer, and very dense to dense coarse-grained layers of sand and gravel with silt and clay fines. Two falling-head infiltration tests performed at 5 feet below ground surface in each test pit showed no measurable drop in water levels, indicating an infiltration rate of 0 inches per hour and a recommended hydrologic soil group of D. The report provides the results of the subsurface exploration and infiltration testing to characterize subsurface conditions for design of the stormwater facilities.
The related federal contract opportunity is a solicitation for a campus-wide infrastructure systems retrofit project at the White City VA Southern Oregon Rehabilitation Center and Clinics. As a competitive Service-Disabled Veteran-Owned Small Business set-aside, the contractor will provide all labor, project management, materials and equipment to complete the stated scope of work. The location is the White City VA facility in White City, Oregon, with a construction value between $10-20 million. The NAICS code is 236220 and the soliciting agency is the Department of Veterans Affairs Headquarters.
View the file
Other files
Show all 46
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4 4 1 2 S W C O R B E T T A V E N U E , P O R T L A N D , O R 9 7 2 3 9 5 0 3 . 2 4 8 . 1 9 3 9 M A I N 8 6 6 . 7 2 7 . 0 1 4 0 F A X P B S U S A . C O M
December 5, 2019
Mr. Bill Wilson William Wilson Architects 1010 SW 11th Avenue Portland, Oregon 97205
Regarding: Geotechnical Engineering Letter Report – Infiltration Testing White City VA Retention Pond Design 8495 Crater Lake Highway
White City, Oregon 97503 PBS Project 70995.002
Dear Mr. Wilson:
PBS Engineering and Environmental Inc. (PBS) is pleased to provide this letter summarizing the results of infiltration testing completed at the Veteran Affairs Department (VA) located in White City, Oregon.
PROJECT UNDERSTANDING
PBS understands that a new stormwater detention and treatment facility will be constructed at the northern end of the White City VA.
SCOPE OF WORK
Subsurface Exploration for Infiltration testing Subsurface conditions were explored by excavating two test pits, designated as TP-1 and TP-2, using a Deere 310J backhoe to depths of 10 feet below the existing ground surface (bgs). The test pits were logged, observed groundwater levels noted, and representative soil samples collected by a member of the PBS geotechnical engineering staff.
Field Infiltration Testing Two infiltration tests were completed, one in each test pit, at depths of approximately 5 feet bgs. The infiltration tests were performed in general accordance with the Rogue Valley Stormwater Quality Design Manual test procedures. A soil sample was collected immediately below the infiltration test depth in each test pit. The test pits were extended approximately 5 feet below the depth of the infiltration test.
Soils Testing Samples returned to our PBS laboratory were classified in general accordance with the Unified Soil Classification, Visual-Manual Procedure. Laboratory testing was not performed due to the degree of cementation that was observed throughout the subsurface materials.
Deliverable This geotechnical engineering letter report was prepared containing the results of our findings, including the following information:
• Field exploration logs and site plan showing approximate exploration locations
• Infiltration test results
White City VA Geotechnical Engineering Letter Report – Infiltration Testing
70995.002
• Groundwater considerations
SUBSURFACE CONDITIONS
Site Soils Two test pits were excavated to depths of 10 feet bgs on November 12, 2019, to perform field infiltration testing.
Both test pits were completed within the area of the proposed stormwater facilities (Figure 1).
PBS has summarized the subsurface units as follows:
Lean CLAY with SAND
(CL):
Hard, brown, lean clay with sand and trace gravel was encountered at the surface of both test pits to approximately 1 foot bgs. The clay exhibited medium plasticity and contained fine to medium sand and fine angular gravel in TP-1, which we have interpreted as fill. Rootlets were present to a depth of approximately 1 foot bgs.
Cemented SILT, SAND, and GRAVEL:
An approximately 6-inch-thick, iron-oxide cemented hardpan layer was encountered beneath the lean clay in both test pits. In TP-1, the hardpan consisted of a cemented gravel with sand and silt, and in TP-2 the hardpan consisted of a cemented silty sand.
GRAVEL with SILT and SAND (GW-SM) to SAND with SILT and
GRAVEL (SW-SM):
Very dense to dense, coarse-grained layers of sand and gravel were encountered within a matrix of silt and clay fines beneath the hardpan. These layers were also cemented and difficult to excavate. The sand and gravel were fine to coarse with rounded gravel clasts. Cobbles were encountered at approximately 7 feet bgs within this layer in TP-1.
Groundwater Static groundwater was not encountered at the time of our explorations to the depth explored. However, based on a review of regional groundwater logs provided by the Oregon Water Resources Department (OWRD), we anticipate that the static groundwater level may be present at a depth less than 20 feet bgs. Please note that groundwater levels can fluctuate during the year depending on climate, irrigation season, extended periods of precipitation, drought, and other factors.
INFILTRATION TESTING
PBS completed two open-hole, falling-head infiltration tests in test pits TP-1 and TP-2 at a depth of approximately 5 feet bgs. The infiltration tests were conducted within an approximately 2-foot by 2-foot depression approximately 1-foot deep that was excavated at the bottom of the test pit. After a period of saturation, the height of the water column in the excavation was then measured initially and at regular, timed intervals. No measurable drop of the water levels was observed in either of the infiltration tests.
Table 1. Infiltration Test Results
Test Location Depth (feet bgs) Field Measured Infiltration Rate (in/hr)
Recommended Hydrologic Soil Group*
TP-1 5 0 D
TP-2 5 0 D
*The recommended hydrologic soil group classification is based upon infiltration rates and soil classification.
Soil types can vary significantly over relatively short distances. The infiltration rates noted above are representative of one discrete location and depth. Installation of infiltration systems within the layer the field rate was measured is considered critical to proper performance of the systems.
The United States Department of Agriculture (USDA) categorizes soils in four hydrologic soil groups, A through D, and are designated mainly by particle size and hydraulic conductivity. Table 2 below shows general characteristics of each group as they are identified by the USDA.
Table 2. USDA Hydrologic Soil Group Parameters (USDA, 2009)
Soil Properties Hydrologic Soil Group A B C D
Saturated Hydraulic Conductivity (k) (inches/hour) k>5.67 1.42<k<5.67 0.14<k<1.42 k<0.14
LIMITATIONS
This report has been prepared for the exclusive use of the addressee, and their architects and engineers, for aiding in the design and construction of the proposed development and is not to be relied upon by other parties. It is not to be photographed, photocopied, or similarly reproduced, in total or in part, without express written consent of the client and PBS. It is the addressee's responsibility to provide this report to the appropriate design professionals, building officials, and contractors to ensure correct implementation of the recommendations.
The opinions, comments, and conclusions presented in this report are based upon information derived from our literature review, field explorations, and engineering analyses. It is possible that soil, rock, or groundwater conditions could vary between or beyond the points explored. If soil, rock, or groundwater conditions are encountered during construction that differ from those described herein, the client is responsible for ensuring that PBS is notified immediately so that we may reevaluate the recommendations of this report.
Unanticipated fill, soil and rock conditions, and seasonal soil moisture and groundwater variations are commonly encountered and cannot be fully determined by merely taking soil samples or completing explorations such test pits. Such variations may result in changes to our recommendations and may require additional funds for expenses to attain a properly constructed project; therefore, we recommend a contingency fund to accommodate such potential extra costs.
The scope of work for this subsurface exploration and geotechnical report did not include environmental assessments or evaluations regarding the presence or absence of wetlands or hazardous substances in the soil, surface water, or groundwater at this site.
If there is a substantial lapse of time between the submission of this report and the start of work at the site, if conditions have changed due to natural causes or construction operations at or adjacent to the site, or if the basic project scheme is significantly modified from that assumed, this report should be reviewed to determine the applicability of the conclusions and recommendations presented herein. Land use, site conditions (both on and off site), or other factors may change over time and could materially affect our findings; therefore, this report should not be relied upon after three years from its issue, or in the event that the site conditions change.
ADDITIONAL SERVICES
Future development plans and construction specifications should be reviewed by PBS for conformance with the geotechnical recommendations for site development. Additionally, geotechnical-related aspects of construction, such as footing, slab, and pavement subgrades, underpinning of existing structures, shoring installation, and preparation of structural fill and backfill, should be observed by a representative of PBS.
CLOSING
We trust this letter meets your current needs. Please contact Ryan White at 503.539.5028 or Ryan.White@pbsusa.com with any questions or comments.
Sincerely, Shaun Cordes, RG, CEG Project Engineering Geologist
Ryan White, PE, GE Principal/Geotechnical Engineering Group Manager
Attachments: Figure 1 Site Plan Table A-1 Terminology Used to Describe Soil
Table A-2 Key to Test Pit and Boring Log Symbols Figures A1–A2 Logs for Test Pits TP-1 and TP-2
SC:RW:rg
6/30/2020 Exp. 7/1/2020
TP-2
TP-1
1L:\ Gi s\G
EO
TE
CH
\pr oje ct\ 5.0 \fig _0 1_
OR
.m xd ∙ M od ifie d B y:
sh au nc ∙ D ate Sa ve d:
/5/ 9:
:15
AM
DAT E: DEC 2019 ∙ PROJECT: 70995.002
FIGURE
SITE PLAN
WHIT E CIT Y VA RET ENT ION
POND DESIGN
WHIT E CIT Y, OREGON
0 250 500125 Feet 1 inch = 250 feet
EXPLANATION
T P-1 - Test pit nam e and approxim ate location w ith infiltration test
Notes: Goog le Earth im ag ery
Salem
Eugene
Medford
Portland
Site
Hwy 62
Table A-1
Terminology Used to Describe Soil
Soil Descriptions
Soils exist in mixtures with varying proportions of components. The predominant soil, i.e., greater than 50 percent based on total dry weight, is the primary soil type and is capitalized in our log descriptions (SAND, GRAVEL, SILT, or CLAY). Smaller percentages of other constituents in the soil mixture are indicated by use of modifier words in general accordance with the
ASTM D2488-06 Visual-Manual Procedure. “General Accordance” means that certain local and common descriptive practices may have been followed. In accordance with ASTM D2488-06, group symbols (such as GP or CH) are applied on the portion of soil passing the 3-inch (75mm) sieve based on visual examination. The following describes the use of soil names and modifying terms used to describe fine- and coarse-grained soils.
Fine-Grained Soils (50% or greater fines passing 0.075 mm, No. 200 sieve)
The primary soil type, i.e., SILT or CLAY is designated through visual-manual procedures to evaluate soil toughness, dilatency, dry strength, and plasticity. The following outlines the terminology used to describe fine-grained soils, and varies from ASTM
D2488 terminology in the use of some common terms.
Primary soil NAME, Symbols, and Adjectives Plasticity
Description
Plasticity
Index (PI)
SILT (ML & MH) CLAY (CL & CH) ORGANIC SOIL (OL & OH)
SILT Organic SILT Non-plastic 0 – 3
SILT Organic SILT Low plasticity 4 – 10
SILT/Elastic SILT Lean CLAY Organic SILT/ Organic CLAY Medium Plasticity 10 – 20
Elastic SILT Lean/Fat CLAY Organic CLAY High Plasticity 20 – 40
Elastic SILT Fat CLAY Organic CLAY Very Plastic >40
Modifying terms describing secondary constituents, estimated to 5 percent increments, are applied as follows:
Description % Composition
With Sand % Sand ≥ % Gravel 15% to 25% plus No. 200
With Gravel % Sand < % Gravel
Sandy % Sand ≥ % Gravel ≤30% to 50% plus No. 200
Gravelly
% Sand < % Gravel
Borderline Symbols, for example CH/MH, are used when soils are not distinctly in one category or when variable soil units contain more than one soil type. Dual Symbols, for example CL-ML, are used when two symbols are required in accordance with ASTM D2488.
Soil Consistency terms are applied to fine-grained, plastic soils (i.e., PI > 7). Descriptive terms are based on direct measure or correlation to the Standard Penetration Test N-value as determined by ASTM D1586-84, as follows. SILT soils with low to non-plastic behavior (i.e., PI < 7) may be classified using relative density.
Consistency
Term SPT N-value
Unconfined Compressive Strength tsf kPa
Very soft Less than 2 Less than 0.25 Less than 24
Soft 2 – 4 0.25 – 0.5 24 – 48
Medium stiff 5 – 8 0.5 – 1.0 48 – 96
Stiff 9 – 15 1.0 – 2.0 96 – 192
Very stiff 16 – 30 2.0 – 4.0 192 – 383
Hard Over 30 Over 4.0 Over 383
SAMPLING DESCRIPTIONS
Table A-2
Key To Test Pit and Boring Log Symbols S P T D ri ve
S am p le r
S ta n d ar d P e n e tr at io n T e st
A
T M
D
S h e lb y T u b e P u sh
S am p le
T M
D
S p e ci al iz e d D ri ve
S am p le rs
(D e ta ils N o te d o n L o g s)
S p e ci al iz e d D ri ll o r
P u sh am p le r (D e ta ils N o te d o n
Lo g s)
G ra b S am p le
R o ck
C o ri n g I n te rv al
S cr e
(W at e r o r
A ir S a m p lin
W at e r
Le ve l D u ri
D ri lli n g /E xc av at io n W at e r
Le ve l A ft ri lli n g /E xc av at io
LOG GRAPHICS
PP Pocket Penetrometer HYD Hydrometer Gradation
TOR Torvane SIEV Sieve Gradation
DCP DS Direct Shear
ATT Atterberg Limits DD Dry Density
PL Plasticity Limit CBR California Bearing Ratio
LL Liquid Limit RES Resilient Modulus
PI Plasticity Index VS Vane Shear
P200 Percent Passing US Standard No. 200 Sieve bgs Below ground surface
OC Organic Content MSL Mean Sea Level
CON Consolidation HCL Hydrochloric Acid
UC Unconfined Compressive Strength
Details of soil and rock classification systems are available on request. Rev. 02/2017
Dynamic Cone Penetrometer
Geotechnical Testing Acronym Explanations
Lithology Boundary:
separates distinct units
(i.e., Fill, Alluvium, Bedrock) at approximate depths inciated
Sampler
Type
Sample
Recovery Sample
Interval
Instrumentation Detail Sampling Symbols Soil and Rock
Well Pipe
Piezometer
Piezometer
Ground Surface
Well Cap
Bottom of Hole
S o il o r R o ck
T y p e s
Well Seal
Well Screen
Soil-type or Material-type
Change Boundary: separates soil and material changes within the same lithographic unit at approximate depth indicated
Table A-1
Terminology Used to Describe Soil
Soil Descriptions
Coarse - Grained Soils (less than 50% fines)
Coarse-grained soil descriptions, i.e., SAND or GRAVEL, are based on the portion of materials passing a 3-inch (75mm) sieve.
Coarse-grained soil group symbols are applied in accordance with ASTM D2488-06 based on the degree of grading, or distribution of grain sizes of the soil. For example, well-graded sand containing a wide range of grain sizes is designated SW;
poorly graded gravel, GP, contains high percentages of only certain grain sizes. Terms applied to grain sizes follow.
Material NAME Particle Diameter
Inches Millimeters
SAND (SW or SP) 0.003 – 0.19 0.075 – 4.8
GRAVEL (GW or GP) 0.19 – 3 4.8 – 75
Additional Constituents:
Cobble 3 – 12 75 – 300
Boulder 12 – 120 300 – 3050
The primary soil type is capitalized, and the fines content in the soil are described as indicated by the following examples.
Percentages are based on estimating amounts of fines, sand, and gravel to the nearest 5 percent. Other soil mixtures will have similar descriptive names.
Example: Coarse-Grained Soil Descriptions with Fines
>5% to < 15% fines (Dual Symbols) ≥15% to < 50% fines
Well graded GRAVEL with silt: GW-GM Silty GRAVEL: GM
Poorly graded SAND with clay: SP-SC Silty SAND: SM
Additional descriptive terminology applied to coarse-grained soils follow.
Example: Coarse-Grained Soil Descriptions with Other Coarse-Grained Constituents
Coarse-Grained Soil Containing Secondary Constituents
With sand or with gravel ≥ 15% sand or gravel
With cobbles; with boulders Any amount of cobbles or boulders.
Cobble and boulder deposits may include a description of the matrix soils, as defined above.
Relative Density terms are applied to granular, non-plastic soils based on direct measure or correlation to the Standard
Penetration Test N-value as determined by ASTM D1586-84.
Relative Density Term SPT N-value
Very loose 0 – 4
Loose 5 – 10
Medium dense 11 – 30
Dense 31 – 50
Very dense > 50
0.0
1.0
1.5
4.5
10.0
Infiltration testing completed at 5 feet bgs
PP = >4.5 tsfPP
Hard, brown, lean CLAY (CL) with sand and roots; medium to high plasticity; fine to medium sand; moist
Olive brown, well-graded GRAVEL (GW-GM) with silt and sand; non-plastic;
fine to coarse sand; fine to coarse, subrounded gravel; iron staining; moderate cementation; moist Olive brown to brown, well-graded SAND (SW-SM) with silt and gravel; non-plastic;
fine to coarse sand; fine to coarse, rounded gravel; weak cementation; moist
Olive brown, well-graded GRAVEL (GW-GM) with silt and sand; non-plastic;
fine to coarse sand; fine to coarse, rounded gravel; moist cobbles at 7 feet bgs
Final depth 10.0 feet bgs; test pit backfilled with excavated material to existing ground surface. Groundwater not encountered at time of exploration.
APPROX. TEST PIT TP-1 LOCATION:
(See Site Plan)
0 50 100
MOISTURE
CONTENT %
STATIC
PENETROMETER
DYNAMIC CONE
PENETROMETER
COMMENTS
Lat: 43.444809 Long: -122.840027
T
E S
T P
IT
L
O G
P E
R P
A G
E
5.
2_ T
P 1-
2_
.G
P J
P B
S _D
A T
A T
M P
L_ G
E O
.G
T
P
R
IN
T D
A T
E
/2
1/
:R P
G
G R
A P
H
IC
LO
G
TEST PIT TP-1
PBS PROJECT NUMBER:
70995.002
DEPTH
FEET
FIGURE A1LOGGED BY: D. Eibert
COMPLETED: 11/12/19
WHITE CITY, OREGON
Lines representing the interface between soil/rock units of differing description are approximate only, inferred where between samples, and may indicate gradual transition.
EXCAVATION METHOD: Deere Backhoe with 24" Bucket EXCAVATED BY: Taylor Site Development Inc.
T E
S T
IN
G
D E
P T
H
S A
M P
LE
T
Y
M P
LE
ID
WHITE CITY VA RETENTION POND
MATERIAL DESCRIPTION
Surface Conditions: Soil and Roots
S -1
S -2
S -3
0 50 100 0.0
2.0
4.0
6.0
8.0
10.0
12.0
0.0
1.0
1.5
2.5
3.5
10.0
Infiltration testing completed at 5 feet bgs
Difficult digging from 7 to 10 feet bgs
PP = >4.5 tsfPP
Hard, brown, lean CLAY (CL) with sand and roots; medium plasticity; fine to medium sand; moist
Orange, silty SAND (SM); non-plastic; fine to medium sand; iron staining; moderate cementation; moist Olive brown, silty SAND (SM) with gravel;
non-plastic; fine to coarse sand; fine to coarse, rounded gravel; moderate cementation; moist Brown, silty SAND (SM); non-plastic; fine sand; moist
Brown, well-graded GRAVEL (GW-GM) with silt and sand; non-plastic; fine to coarse sand; fine to coarse, rounded gravel; moist
Final depth 10.0 feet bgs; test pit backfilled with excavated material to existing ground surface. Groundwater not encountered at time of exploration.
APPROX. TEST PIT TP-2 LOCATION:
(See Site Plan)
0 50 100
MOISTURE
CONTENT %
STATIC
PENETROMETER
DYNAMIC CONE
PENETROMETER
COMMENTS
Lat: 42.444768 Long: -122.839255
T
E S
T P
IT
L
O G
P E
R P
A G
5.
2_ T
P 1-
2_
.G
P J
P B
S _D
A T
A T
M P
L_ G
E O
.G
T
R
IN
T D
A T
E
/2
1/
:R P
G
G R
A P
H
IC
LO
G
TEST PIT TP-2
PBS PROJECT NUMBER:
70995.002
DEPTH
FEET
FIGURE A2LOGGED BY: D. Eibert
COMPLETED: 11/12/19
WHITE CITY, OREGON
Lines representing the interface between soil/rock units of differing description are approximate only, inferred where between samples, and may indicate gradual transition.
EXCAVATION METHOD: Deere Backhoe with 24" Bucket EXCAVATED BY: Taylor Site Development Inc.
T E
S T
IN
G
D E
P T
H
S A
M P
LE
T
Y
M P
LE
ID
WHITE CITY VA RETENTION POND
MATERIAL DESCRIPTION
Surface Conditions: Soil and Roots
S -1
S -2
S -3
0 50 100 0.0
2.0
4.0
6.0
8.0
10.0
12.0
| PROJECT UNDERSTANDING |
| SCOPE OF WORK |
| Subsurface Exploration for Infiltration testing |
| Field Infiltration Testing |
| Soils Testing |
| Deliverable |
| Subsurface conditions |
| Site Soils |
| Groundwater |
| Infiltration Testing |
| Hydrologic Soil Group |
| LIMITATIONS |
| Additional Services |
| Future development plans and construction specifications should be reviewed by PBS for conformance with the geotechnical recommendations for site development. Additionally, geotechnical-related aspects of construction, such as footing, slab, and pavem... |
| closing |
| 2019-12-05T12:52:27-0800 | |
| Shaun Cordes |
| 2019-12-05T13:10:23-0800 | |
| Ryan White, PE, GE |
File details come from the government source that posted it. Updated .