Attachment 6 - Drawings ELECTRICAL LIGHTING SECOND FLOOR PLAN.pdf
PDF 5 MB Posted
- Solicitation number
- 36C77623R0103
About this file
This package of construction documents outlines requirements for an addition and renovations project at the Joint Ambulatory Care Clinic in Pensacola, Florida. The project involves upgrades and renovations to existing medical facilities as well as construction of new parking areas. Drawings and specifications cover proposed architectural, mechanical, electrical, and plumbing systems. Estimated project costs total over $10 million. The solicitation is open to small businesses with a response date in late 2022 and anticipated award in early 2023.
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OS OS
O S
O S
O S
O S
OS
OS O
S
O S
O S
O S
O S
O S
O S
OS
OS
OS
OS
OS
O S
OS
OS
O S
O S
O S
O S
OS
OS
O S
O S
O S
OS
3 33
OS
OS
OS
E E
D D
C C
B B
RESTROOM
2G118
RESTROOM
2G116
RESTROOM
2G114
RESTROOM
2G112
PHLEBOTOMY
2G101
SPECIMEN DROP OFF
2G111
SPECIMEN 09
2G113
LAB OFFICE TOUCHDOWN
2G123
STAFF RESTROOM
2G126LAB OFFICE
2G127
CORRIDOR
C2-101
COLD STORAGE
2G121
LAB OFFICE
2G125
WAITING ROOM
2G100
RECEPTION
2G103
SPECIMEN 08
2G105
SPECIMEN 07
2G107
SPECIMEN 06
2G109
CORE LAB
2G117
SPECIMEN 05
2G110
SPECIMEN 04
2G108
SPECIMEN 03
2G106
SPECIMEN 02
2G104
SPECIMEN 01
2G102
RESTROOM
2G100A
STAFF RESTROOM
2G144
VESTIBULE
2G117A
CORRIDOR
C2-99
CONFERENCE/ BREAK ROOM
2G143
TREATMENT 2
2G135C
TREATMENT 1
2G135B
NURSE STATION
2G135A
TREATMENT 3
2G135D
TREATMENT 4
2G135E
TREATMENT 5
2G135F
TREATMENT 6
2G135G
TREATMENT 7
2G135H
TREATMENT 8
2G135I
TREATMENT 9
2G135J
TREATMENT 10
2G135K
MED ROOM
2G142
RESTROOM
2G139
RESTROOM
2G138
INFUSION CLINIC
2G135
SOILED UTILITY
2G140
BULK STORAGE
2G120
STERILE SUPPLY
2G141
EXAM / CONSULT
2G136
ADMIN SUPPORT
2G137
RECEPTION
2G134
WAITING ROOM
2G133
HAC
2G132
STERILE SUPPLY
2G119
ELECTRICAL
2G131
FILE CLOSET
2G130
CONSULT
2G129
CORRIDOR
C2-97
CONSULT
2G128
NEG. PRESSURE LAB
MICROBIOLOGY
2G122
CORE LAB
2G117CORE LAB
2G117
INFUSION CLINIC
2G135
SPECIMEN 10
2G115
B
B
B
B
B
B
B
B
B
B
B B B H H H H H H
H H
H H
B
B
H
H H
H
A A A
A
A
B
B
B
B
B
B
B
B
B
B
B BBB B B
B BB B
B B
B
B
B
B
B
B
B
B B B B B B
B B
B B
B B
B
B
B
B
H H
H H
A
A
AA
A AA
A
A
A A A A
A A
A
A A
A
A
A A
A
A
A
AA
A1
A A A
A
A AAAAA
A A A A
A
A
A
A
A
A
A
C C
C C
C C
C C
C
C
C C
C C
C C
F
F
X
X
X
X
A
AAAA
A
A A A
A A A
A
X
HH
H H
A
A
A
A A
A
A A
A
A
A
A A
A
A
A
A
A
A
A A A
A A
AA
TELECOM ROOM
2G145
F F F
A
A A
1 1
B B
R1
H2F - 3
X
R1
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
EM
X
H2F - 11
EM
H2F - 13
H2F - 1
H2F - 9
H2F - 7
ELH2F - 1
H2F - 5
EM
A
EM
EM
(TYP.)
EM
3 TYP.
TYP.
EM
ECH2F - 7
C C C
C
C
C
C
C
C
C C C
CCC
C
C
A. NO WORK REQUIRED IN HATCHED AREAS. ALL LIGHTING FIXTURES,
CONTROLS, POWER DEVICES, CIRCUITING AND ASSOCIATED
WIRING SHALL BE EXISTING TO REMAIN.
B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL
RATED WALLS, CEILINGS AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIALS
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILINGS AND
SLABS ASSEMBLY INSTALLED IN ACCORDANCE WITH UL FOR THE
RATED APPLICATION.
C. PROVIDE DUAL TECHNOLOGY OCCUPANCY/VACANCY SENSORS
FOR AUTOMATIC LIGHTING CONTROL IN ALL COMMON SPACES
EXCEPT ELECTRICAL, MECHANICAL AND IT ROOMS.
D. ALL OCCUPANCY AND VACANCY SENSORS SHALL TURN OFF
WITHIN 20 MINUTES OF THE SPACE BECOMING UNOCCUPIED.
E. OCCUPANCY SENSORS SHALL FAILSAFE "ON".
F. LIGHTING CONTROL CONTRACTOR SHALL PROVIDE CONTROLS
AND SENSORS WITH APPROPRIATE COVERAGE PATTERNS AND
ADJUSTMENTS OF SENSITIVITY LEVELS TO PREVENT NUISANCE
SWITCHING ON AND OFF OF LIGHTS.
G. FIXTURES LOCATED IN CORRIDORS, NURSE STATIONS, WAITING
ROOM AND ALL COMMON AREAS SHALL BE CONTROLLED BY
EXISTING BMS SYSTEM VIA LOCAL LCP. LCP IS LOCATED IN LOCAL
ELECTRICAL ROOM. LCP SHALL BE TIED TO EXISTING BMS
LOCATED IN MECHANICAL PENTHOUSE. COORDINATE EXACT
LOCATION, WIRING, AND ALL OTHER ASSOCIATED REQUIREMENTS.
H. FOR ALL FIXTURES CONTAINING EMERGENCY BATTERY PACKS,
THEY SHALL BE INSPECTED AND TESTED MONTHLY. SEE LIGHTING
FIXTURE SCHEDULE ON SHEET E-502 FOR ADDITIONAL
INFORMATION.
I. UPON ACTIVIATION OF THE BUILDING FIRE ALARM, LIGHT FIXTURES
DESIGNATED AS LIFE SAFETY SHALL AUTOMATICALLY TURN "ON"
AND LOCAL LIGHTING CONTROLS ARE OVERRIDEN. PROVIDE
RELAY AS REQUIRED.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
N
SEC 6
(F)
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:4
P
M
EL102F
ELECTRICAL LIGHTING SECOND FLOOR PLAN -
AREA F
520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F3 ELECTRICAL LIGHTING SECOND FLOOR PLAN - AREA F
1 ALL LIGHT FIXTURES IN THIS AREA SHALL BE CONTROLLED BY THE
EXISTING BUILDING MANAGEMENT SYSTEM (BMS) LOCATED IN THE
MECHANICAL PENTHOUSE VIA LOCAL LIGHTING CONTROL PANEL (LCP).
COORDINATE SCHEDULE TIME OF DAY WITH VA.
2 MANUAL OVERRIDE SWITCH FOR CORRIDOR LIGHTING.
3 THE INTENT FOR FIXTURES DESIGNATED WITH A 'H' IN THE TREATMENT
AREA IS TO HAVE THEM CONTROLLED LOCALLY BY THE CHAIR
CONTROLLER IN THAT ROOM.
Revisions: Date:
2022.09.23
10.07.2022
2022.10.07
J
J
J
J
J
J
J J
J
J
J
J
JJ
J
J
J
J
J
J J
J
J
J J
J
J
J
J
J
J
J
J J
J
J
M
J
J
J
J J
J
J
J
J
J JJ
J JJ
J JJ
J JJ
JJJ
JJ J
JJ J
J
J
J
J
J
JJ
J
J
J
J
J
J
J J
J J
J
J
J
J
J
J
J J
J
J
J
J
J
J
J
J
J
J
J
J J
J
J J
J
J
J
J
J
J
J
J
J J
J
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
E E
D D
C C
B B
H2F
T-H2F
L2F2
ELH2F
ECH2F
T-ECH2F
ECL2F
CONSULT
2G128
CONSULT
2G129
FILE CLOSET
2G130 ELECTRICAL
2G131
CORRIDOR
C2-101
LAB OFFICE
2G127
STAFF RESTROOM
2G126
LAB OFFICE
2G125
LAB OFFICE TOUCHDOWN
2G123
RESTROOM
2G118
SPECIMEN 10
2G115
SPECIMEN 09
2G113RESTROOM
2G116
RESTROOM
2G114
SPECIMEN DROP OFF
2G111
COLD STORAGE
2G121
BULK STORAGE
2G120
STERILE SUPPLY
2G119
HAC
2G132
NEG. PRESSURE LAB
MICROBIOLOGY
2G122
STERILE SUPPLY
2G141
WAITING ROOM
2G133
CORE LAB
2G117
SPECIMEN 06
2G109
SPECIMEN 07
2G107
SPECIMEN 08
2G105
RECEPTION
2G103
WAITING ROOM
2G100 PHLEBOTOMY
2G101
RESTROOM
2G100A
SPECIMEN 01
2G102
SPECIMEN 02
2G104
SPECIMEN 03
2G106
SPECIMEN 04
2G108
SPECIMEN 05
2G110
CONFERENCE/ BREAK ROOM
2G143
CORRIDOR
C2-99
VESTIBULE
2G117A
STAFF RESTROOM
2G144
TREATMENT 3
2G135D
NURSE STATION
2G135A
TREATMENT 4
2G135E
TREATMENT 5
2G135F
MED ROOM
2G142
TREATMENT 6
2G135G
TREATMENT 7
2G135H
TREATMENT 10
2G135K
TREATMENT 8
2G135I
TREATMENT 9
2G135J
INFUSION CLINIC
2G135
SOILED UTILITY
2G140
RESTROOM
2G139
RESTROOM
2G138
ADMIN SUPPORT
2G137
RECEPTION
2G134
EXAM / CONSULT
2G136
CORRIDOR
C2-97
RESTROOM
2G112
REF
CORE LAB
2G117TV
9' AFF
QMATIC TV
+60" AFF
COPIER
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
STACKED
TV
+60" AFF
TELECOM ROOM
2G145
ECL2FIT
SENSOR
COPIER
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
WARMING
CABINET
UC FRZ
SENSOR
SENSOR
TV
+72" AFF
UC
REF
OMNI
CELL
OMNI
CELL
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
(TYP.)
E9
E8
E15
E16
PRINTER PRINTER
E12
E14
E13
E8
E11
E10
PRINTER
PRINTER
39" AFF
E17
E13
E2
E1F E1E
E1D
E1C
E1B
E1A
COPIERREF FRZ FRZ FRZ
PRINTER
PRINTER
E18
E25E26
EFRE2
EFRE3
E4
E3
SENSOR
E5
E5A
E5B
E5C
E6C
E6
E6A
E6B
E7
PRINTER
REF FRZ
E20 E23
E24
E22
E19
(TYP.)
(TYP.)
E-7
OMNI
CELL
LCP
EQH2F
ECL2FIT - 1
ECL2FIT - 3
E1G
ECL2F2 - 12
ECL2F2 - 14
ECL2F2 - 47
ECL2F2 - 44
ECL2F2 - 45
ECL2F2 - 43
L2F - 8
ECL2F2 - 27
ECL2F2 - 25
ECL2F2 - 23
ECL2F2 - 35
ECL2F2 - 37
ECL2F2 - 39
ECL2F2 - 33
ECL2F2 - 21
L2F2 - 3
L2F2 - 1
L2F2 - 5
L2F2 - 7
L2F2 - 43
L2F2 - 11
L2F - 17
L2F - 19
L2F - 21
L2F - 23
L2F - 12
L2F2 - 13
L2F - 25
GFCI
GFCI
GFCI
GFCI
GFCI
L2F2 - 15
L2F2 - 17
L2F2 - 19
L2F2 - 23
L2F2 - 8
L2F2 - 10
L2F2 - 12
L2F2 - 14
L2F2 - 16
L2F2 - 41
L2F2 - 20
L2F2 - 22
L2F2 - 24
L2F2 - 26
L2F2 - 28
GFCI
GFCI
ECL2F - 29
ECL2F - 31
ECL2F - 33
ECL2F - 35
L2F2 - 30
L2F2 - 32
L2F2 - 34
L2F2 - 36
L2F2 - 38
GFCI
GFCI
ICE MAKER
ECL2F - 30
ECL2F - 32
ECL2F - 37
ECL2F - 3
L2F2 - 18
ECL2F2 - 41
EWC
GFCI
ECL2F2
E7A
L2F2 - 25 L2F2 - 27
L2F2 - 29ECL2F2 - 1 ECL2F2 - 3
ECL2F2 - 5
GFI
GFI
L2F - 1
E6
E5
TR
TR
TR
TR
TR
L2F2 - 37
ECL2F2 - 22
ECL2F2 - 20
KIOSK
L2F2 - 9
ECL2F2 - 42
ECL2F2 - 22
15 15
ECL2F2 - 10
ECL2F2 - 8
ECL2F2 - 49
ECL2F2 - 51
ECL2F2 - 53
ECL2F2 - 55 ECL2F2 - 57
ECL2F2 - 52
L2F2 - 21
ECL2F2 - 54
ECL2F2 - 56
ECL2F2 - 58
ECL2F2 - 60
ECL2F2 - 59 ECL2F2 - 61
ECL2F2 - 62
ECL2F2 - 64
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
SENSOR
39" AFF
39" AFF
TREATMENT 1
2G135B
TREATMENT 2
2G135C
L2F - 1
(TYP.)
L2F - 3
L2F - 1
L2F2 - 31
ECL2F2 - 7
L2F - 3
L2F2 - 33
ECL2F2 - 9
L2F - 3
L2F2 - 35
ECL2F2 - 11
L2F - 5
L2F2 - 42
ECL2F2 - 15
L2F - 5
L2F2 - 40
ECL2F2 - 13
L2F - 7
ECL2F2 - 17
L2F2 - 44
ECL2F - 39
L2F - 7
ECL2F2 - 19
L2F2 - 46
ECL2F2 - 63
ECL2F2 - 40
ECL2F2 - 38
39" AFF
39" AFF
ECL2F2 - 66
39" AFF
39" AFF
39" AFF
39" AFF
39" AFF
ECL2F - 60
ECL2F - 60
GBB
TGB
MED GAS ALARM PANEL
L2F
L2FIT
ECL2FIT - 7
ECL2FIT - 11
ECL2FIT - 8
ECL2FIT - 9
UPS
A A BB
A A BB
ECL2FIT - 17,19,21
ECL2FIT - 10
ECL2FIT - 12,14,16
ECL2FIT - 18,20
ECL2FIT - 22,24
L2FIT - 1,3,5
L2FIT - 7,9,11
ECL2FIT - 5
L2FIT - 13,15
L2FIT - 17,19
(TYP.)
A. NO WORK REQUIRED IN HATCHED AREAS. ALL LIGHTING FIXTURES,
CONTROLS, POWER DEVICES, CIRCUITING AND ASSOCIATED
WIRING SHALL BE EXISTING TO REMAIN.
B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL
RATED WALLS, CEILINGS AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIALS
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILINGS AND
SLABS ASSEMBLY INSTALLED IN ACCORDANCE WITH UL FOR THE
RATED APPLICATION.
C. ELECTRICAL CONTRACTOR SHALL COORDINATE ANY WALL
MOUNTED ITEM (ELECTRICAL/DATA/LIGHT) WITH ARCHITECT PRIOR
TO INSTALLATION.
D. FINAL LOCATION OF POWER DEVICES SHALL BE COORDINATED
WITH THE VA DURING WALK THROUGH PRIOR TO ROUGH-IN.
E. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL
EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO
ORDERING AND INSTALLATION.
F. ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER AND
CONNECTION REQUIREMENTS FOR ALL EQUIPMENT PRIOR TO
ORDERING AND INSTALLATION. VERIFY ALL DEVICE LOCATION AND
MOUNTING HEIGHT. MAKE ADJUSTMENT IN FIELD TO MATCH
ACTUAL EQUIPMENT NAMEPLATE BEING INSTALLED.
G. ALL CONTROL WIRING SHALL BE INCLUDED AS PART OF THE
MECHANICAL WORK. MECHANICAL CONTRACTOR SHALL ENSURE
THAT ELECTRICAL INTERFACE DEVICES THAT ARE NECESSARY IN
THE ELECTRICAL COMPONENT ARE COORDINATED WITH THE
ELECTRICAL CONTRACTOR.
H. REFER TO ONE-LINE DIAGRAM AND PANEL SCHEDULES FOR
ADDITIONAL INFORMATION.
I. ALL SPECIAL SYSTEMS FURNITURE LOCATED IN THE TREATMENT
SPACES SHALL BE EQUIPPED WITH POWER/NURSE CALL/DATA
FLOOR BOX CONNECTIONS. CONTRACTOR SHALL VERIFY ALL
CONNECTION REQUIREMENTS FOR SELECTED FURNITURE PRIOR
TO INSTALLATION AND BIDDING. POWER SHALL BE HARDWIRED TO
MODULES. ROUTE CABLES THROUGH CABINETRIES AS SHOWN ON
INSTALLATION MANUAL. PROVIDE DUPLEX, DATA AND NURSE CALL
DEVICES AS REQUIRED WITHIN MODULES FOR A FULLY
FUNCTIONAL SYSTEM.
J. FOR ALL OUTLETS LOCATED IN THE CORE LAB AREA, SEE A-404-06,
408 AND LAB CASEWORK FOR ADDITIONAL DETAILS
K. ALL OUTLETS SHALL BE COORDINATED WITH FINAL FURNITURE
LAYOUT TO ENSURE ALL DEVICES ARE ACCESSIBLE.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
LAB EQUIPMENT SCHEDULE
CODE EQUIPMENT DESCRIPTION VOLTS PHASE WATTS NEMA PLUG AMPS/POLES CIRCUIT NUMBER
EFRE2 BIOMED FREEZER
EFRE3 BIOMED FREEZER
E1A IRIS IQ200 ELITE ANALYZER
E1B ARKRAY AUTION MAX AX-4030
*E1C ARKRAY AUTION MAX AX-4030
*E1D ARKRAY CPU
E1E ARKRAY MONITOR
E1F ARKRAY PRINTER
E1G ARKRAY UPS
E2 CENTRIFUGE - THERMO ELECTRON CL2
E3 CENTRIFUGE - STATSPIN EXPRESS 3
E4
E5 BECKMAN ANALYZER DXC 660i
E5A BECKMAN ANALYZER UCTA
E5B BECKMAN ANALYZER DXI 600
E5C EVOQUA ELGA DV 25
E6 BECKMAN ANALYZER DXC 660i
E6A BECKMAN ANALYZER UCTA
E6B BECKMAN ANALYZER DXI 600
E6C EVOQUA ELGA DV 25
*E7 REMISOL SYSTEM - LABTRONICS
*E8 ROCKER-TEST TUBE
*E9 ROCKER-TEST TUBE
*E10 SEDRATE ANALYZER - EXCYTE 20
*E11 G8 HPLC ANALYZER - TOSOH
E12 HEMATEK 3000 SLIDE STAINING
E13 OLYMPUS MICROSCOPE - BX45-TF-S
E14 CELLAVISION DM1200
E15 UNICEL DXH 900
E16 UNICEL DXH 900
*E17 STAGO STA COMPACT ANALYZER
E18 CENTRIFUGE LABORATORY
*E19 POLYMEDCO / OC-AUTO MICRO 80
E20 ABBOT ID NOW ANALYZER
E21 FLAMMABLE CABINET MEDLINE
E22 FUME HOOD - LABCONCO
E23 VORTEX MIXER - GENIE 2
E24 BD MAX ANALYZER
E25 VORTEX MIXER - GENIE
E26 QUICKSPIN PLUS / EBA200S
E27 FLAMMABLE CABINET
CENTRIFUGE - SILENCER S2510
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
220-240 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
120 1
208 1
208 1
120 1
120 1
120 1
120 1
NA
120 1
120 1
120 1
120 1
120 1
NA
360 5-20P 20A/1P
1200 5-20P 20A/1P
4800 L6-20R 20A/2P
1800 5-20P 20A/1P
1800 5-20P 20A/1P
1200 5-20P 20A/1P
220-240 4800 L6-20R 20A/2P
1800 5-20P 20A/1P
1800 5-20P 20A/1P
1200 5-20P 20A/1P
1200 5-20P 20A/1P
108 5-15P 20A/1P ECL2F2 - 36
108 5-15P 20A/1P
200 5-20P 20A/1P ECL2F2 - 34
200 5-20P 20A/1P ECL2F2 - 34
420 5-20P 20A/1P
180 5-20P 20A/1P
1200 5-20P 20A/1P
720 5-20P 20A/1P
1000 5-20P 20A/1P
1664 6-20P 20A/2P
1664 6-20P 20A/2P
1800 5-20P 20A/1P ECL2F2 - 26
175 5-20P 20A/1P
175 5-20P 20A/1P
114 5-20P 20A/1P ECL2F2 - 24
200 5-20P 20A/1P
200 5-20P 20A/1P
200 5-20P 20A/1P ECL2F2 - 31
1560 5-20P 20A/1P ECL2F2 - 29
1 114 5-20P 20A/1P
1680 5-20P 20A/1P
200 5-20P 20A/1P
150 5-20P 20A/1P
150 5-20P 20A/1P
100 5-20P 20A/1P
100 5-20P 20A/1P
100 5-20P 20A/1P
800 5-20P 20A/1P
ECL2F - 1
NOTE:
1) ALL EQUIPMENT TO BE ON EMERGENCY POWER.
2) SEE ARCHITECTURAL PLANS FOR ELEVATIONS AND ADDITIONAL INFORMATION.
3) COORDINATE ALL POWER REQUIREMENTS WITH EQUIPMENT INSTALLATION MANUAL PRIOR TO INSTALLATION/ORDERING.
4) *MOUNT ABOVE COUNTER; 39" AFF.
ECL2F2 - 53
ECL2F - 5
ECL2F - 7,9
ECL2F - 11
ECL2F - 13
ECL2F - 15
ECL2F - 8,10
ECL2F - 12
ECL2F - 14
ECL2F - 16
ECL2F - 18
ECL2F - 22
ECL2F - 17
ECL2F - 19,21
ECL2F - 23,25
ECL2F - 24
ECL2F - 26
ECL2F - 27
ECL2F - 28
ECL2F - 20
ECL2F - 59
ECL2F - 45
ECL2F - 47
ECL2F2 - 34
ECL2F2 - 34
ECL2F2 - 32
ECL2F2 - 28 ECL2F2 - 30
ECL2F - 45
ECL2F - 45
ECL2F - 45
ECL2F - 45
ECL2F - 45
ECL2F - 41 ECL2F - 43 ECL2F - 34
ECL2F - 36
ECL2F - 40 ECL2F - 49 ECL2F - 38
ECL2F - 42
E7A REMISOL SYSTEM - SERVER STATION 120 1 1200 5-20P 20A/1P ECL2F - 51
ECL2F - 53,55
ECL2F - 56,58
ECL2F2 - 31
N
SEC 6
(F)
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:2
P
M
EP102F
ELECTRICAL POWER SECOND FLOOR PLAN -
AREA F
520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F3 ELECTRICAL POWER SECOND FLOOR PLAN - AREA F
1 PROVIDE POWER TO FURNITURE FEED. COORDINATE TERMINATION
REQUIREMENTS WITH FURNITURE VENDOR.
2 IG CIRCUIT TO BE PROVIDED WITH DEDICATED NEUTRAL AND ISOLATED
EQUIPMENT GROUND FROM MAIN SERVICE BONDING LOCATION.
3 PROVIDE 1-1/4" CONDUIT FOR TV/COMMUNICATIONS AT FURNITURE FEED.
COORDINATE TERMINATION REQUIREMENTS WITH FURNITURE VENDOR.
PROVIDE CABLE WITH ENOUGH SLACK TO MAKE ALL CONNECTIONS. ALL
CABLES SHALL ORIGINATE FROM CLOSEST TELECOMMICATION BACKBOARD.
4 TTB, TELEPHONE TERMINAL BACKBOARD - PROVIDE (2) COATS OF GRAY FLAME
RETARDANT PAINT OR STAMPED/MARKED LISTED FIRE RATED PLYWOOD
BACKBOARD.
5 JUNCTION BOX FOR INFUSION PUMPS. COORDINATE EXACT LOCATION WITH VA
PRIOR TO INSTALLATION.
6 RECEPTACLE FOR TREATMENT CHAIR. COORDINATE EXACT LOCATION WITH VA
PRIOR TO INSTALLATION.
7 WALK-IN COOLER EVAPORATOR COIL. PROVIDE ADDITIONAL 3/4" CONDUITS
WITH CONTROL WIRES TO COOLER CONTROL PANEL AND EVAPORATOR
WITHIN UNIT. COORDINATE ALL REQUIREMENTS PER MANUFACTURER'S
SPECIFICATIONS.
8 JUNCTION BOX FOR WALK-IN COOLER LIGHTS.
9 JUNCTION BOX FLUSH MOUNTED WITH FLOOR. PROVIDE POWER AND DATA
FOR FURNITURE FEED TO SERVE WORKSTATION. RUN WIRES AND CIRCUIT AS
SHOWN, COORDINATE EXACT LOCATION AND DIMENSIONS WITH CASEWORK
DRAWINGS PRIOR TO INSTALLATION.
10 PROVIDE RECEPTACLE AT 72" AFF FOR LAB STAT BOARD. SEE SPECIAL
SYSTEMS PLANS FOR DATA LOCATION.
11 ANALYZER LEFT FACE HOOKUP WALL. SEE ARCHITECTURAL DRAWINGS Q-401F
FOR ELEVATIONS. PROVIDE (1) QUAD OUTLET AND (1) NEMA L6-2OR OUTLET.
EACH OUTLET SHALL BE PROVIDED WITH A DEDICATED CIRCUIT. SEE "LAB
EQUIPMENT SCHEDULE" FOR EQUIPMENT CIRCUIT NUMBER AND COORDINATE
EQUIPMENT LAYOUT AS REQUIRED.
12 ANALYZER RIGHT FACE HOOKUP WALL. SEE ARCHITECTURAL DRAWINGS
Q-401F FOR ELEVATIONS. PROVIDE (1) QUAD OUTLET AND (1) 4 DATA PORT
OUTLET. EACH OUTLET SHALL BE PROVIDED WITH A DEDICATED CIRCUIT. SEE
"LAB EQUIPMENT SCHEDULE" FOR EQUIPMENT CIRCUIT NUMBER AND
COORDINATE EQUIPMENT LAYOUT AS REQUIRED.
13 JUNCTION BOX FOR UNDERCOUNTER LIGHT FIXTURE MOUNTED 62" AFF.
MOUNT ASSOCIATED LIGHT SWITCH 50" AFF.
14 RECEPTACLES SHOWN ON ANALYZER ISLAND ARE SHOWN FOR REFERENCE
ONLY. ACTUAL HOOKUP ARE ON ADJACENT WALL. SEE KEYNOTES # 11-12 AND
LAB EQUIPMENT SCHEDULE ON THIS SHEET FOR ADDITIONAL INFORMATION.
15 JUNCTION BOX MOUNTED AT 18" AFF FOR CASEWORK POWER. COORDINATE
TERMINATION REQUIREMENTS WITH CASEWORK DRAWINGS. PROVIDE
ENOUGH CABLE SLACK TO MAKE ALL CONNECTIONS. COORDINATE EXACT
LOCATION, REQUIREMENTS AND CONNECTIONS WITH LAB CASEWORK
DRAWINGS/VENDOR, MODULAR PHARMACY SOLUTIONS, MPS.
16 RECEPTACLE FOR EQUIPMENT E3 SHOWN ON CASEWORK SHOWN FOR
REFERENCE ONLY. CIRCUIT IS COMING OFF OF ADJACENT WALL AND
THROUGH FURNITURE CHASE.
17 JUNCTION BOX LOCATED ABOVE CEILING FOR CASEWORK POWER.
COORDINATE TERMINATION REQUIREMENTS WITH CASEWORK DRAWINGS.
PROVIDE CONDUIT ABOVE CEILING FROM JUNCTION BOX TO FURNITURE
CHASE AND ENOUGH CABLE SLACK TO MAKE ALL CONNECTIONS. COORDINATE
EXACT LOCATION, REQUIREMENTS AND CONNECTIONS WITH LAB CASEWORK
DRAWINGS/VENDOR, MODULAR PHARMACY SOLUTIONS, MPS.
18 JUNCTION BOX FOR DW SHUT OFF TO STAFF RESTROOM CONTROLLER.
COORDINATE EXACT REQUIREMENTS AND LOCATION WITH PLUMBING AND
OWNER PRIOR TO INSTALLATION.
19 PROVIDE 3/4" CONDUIT NURSE CALL AT FURNITURE FEED. COORDINATE
TERMINATION REQUIREMENTS WITH FURNITURE VENDOR. PROVIDE CABLE
WITH ENOUGH SLACK TO MAKE ALL CONNECTIONS. ALL CABLES SHALL
ORIGINATE FROM NURSE CALL MASTER STATION.
20 JUNCTION BOX MOUNTED ABOVE CEILING FOR UNDERCOUNTER LIGHT
FIXTURE MOUNTED 62" AFF. MOUNT ASSOCIATED LIGHT SWITCH 50" AFF.
21 STACKED DRY-TYPE TRANSFORMERS. CONTRACTOR SHALL PROVIDE STACK
MOUNTING STRUCTURE TO SUPPORT TRANSFORMER.
22 PROVIDE OVERHEAD POWER DROP CORD WITH L21-20 RECEPTACLE.
SPECIAL RECEPT. - SEE NEMA PLUG COLUMN ABOVE FOR SPECIFIC EQUIPMENT OUTLET REQUIREMENTS.
Revisions: Date:
2022.09.23
M
M
E E
D D
C C
B B
A.9 A.9
EF-2F-2
WP
EF-2F-L2
EF-2F-1
30/3P/3R
EQH2F - 8,10,12
30/3P/3R
WP
ECL2F2 - 18
DSSO-2G131
DSSO-2G145
30/2P/3R
30/2P/3R
GFI
WP
GFI
WP
(TYP.)
ECL2F2 - 16
ECL2F2 - 46,48
ECL2FIT - 13,15
30/2P/3R
COOLER
30/2P/3R
COOLER
LPH - 27,29
LPH - 23,25
EQH2F - 1,3,5
EF-2F-L1
L2F2 - 39
A. IT IS THE RESPONSIBILITY OF ALL BIDDERS TO THOROUGHLY
REVIEW AND UNDERSTAND ALL CONSTRUCTION DOCUMENTS. THIS
INCLUDES BUT IS NOT LIMITED TO ALL DRAWINGS, SPECIFICATION
SECTIONS, ETC. THE DRAWINGS ARE SCHEMATIC IN NATURE.
THEREFORE BEFORE STARTING ANY WORK, THE CONTRACTOR
SHALL REVIEW ALL OTHER CONSTRUCTION DOCUMENTS, VERIFY
FIELD CONDITIONS WITHOUT EXTRA COST TO THE OWNER. ANY
MAJOR DISCREPANCIES FOUND SHALL BE BROUGHT TO THE
ATTENTION OF THE ARCHITECT/ENGINEER. THE BASE BID SHALL
REFLECT THE TOTAL COST OF THE NEW EQUIPMENT AND
MATERIALS. NO CHANGE ORDERS SHALL BE ISSUED WITHOUT
WRITTEN CONSENT AND APPROVAL FROM ENGINEER AND
ARCHITECT.
B. CONTRACTOR SHALL BE RESPONSIBLE FOR IDENTIFICATION OF ALL
RATED WALLS, CEILING AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIAL
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILING AND
SLABS ASSEMBLY. CONTRACTOR SHALL PROVIDE AN ASSEMBLY
INSTALLED IN ACCORDANCE WITH UL FOR THE RATED APPLICATION.
C. CONTRACTOR SHALL INSTALL LIGHTNING PROTECTION SYSTEM
REQUIRED TO COMPLY WITH NFPA 780 AND MEET THE
REQUIREMENTS OF UL 96A. CONTRACTOR MAY NEED TO ADD
ADDITIONAL AIR TERMINALS, CONDUCTORS, BONDS, CONNECTORS,
ETC. TO MEET CODE COMPLIANCE. PROVIDE A UL LETTER OF
FINDINGS FOR LIGHTING PROTECTION SYSTEM.
D. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL
EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO ORDERING
AND INSTALLATION.
E. ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER AND
CONNECTION REQUIREMENTS FOR ALL EQUIPMENT PRIOR TO
ORDERING AND INSTALLATION. VERIFY ALL DEVICE LOCATION AND
MOUNTING HEIGHT. MAKE ADJUSTMENT IN FIELD TO MATCH ACTUAL
EQUIPMENT NAMEPLATE BEING INSTALLED.
F. ALL CONTROL WIRING SHALL BE INCLUDED AS PART OF THE
MECHANICAL WORK. MECHANICAL CONTRACTOR SHALL ENSURE
THAT ELECTRICAL INTERFACE DEVICES THAT ARE NECESSARY IN
THE ELECTRICAL COMPONENT ARE COORDINATED WITH THE
ELECTRICAL CONTRACTOR.
G. REFER TO ONE-LINE DIAGRAM AND PANEL SCHEDULES FOR
ADDITIONAL INFORMATION.
H. DISCONNECTS ARE SHOWN MOUNTED ON ASSOCIATED HVAC UNIT
IS FOR DIAGRAMMATICAL PURPOSES ONLY. DISCONNECTS SHALL
NOT BE INSTALLED ON HVAC EQUIPMENT. DISCONNECTS SHALL BE
PROVIDED WITH WEATHERPROOF RESISTANT STAND ALONE
SUPPORTING HARDWARE RATED FOR DISCONNECT WEIGHT AND
WIND LOAD.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
N
SEC 6
(F)
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:3
P
M
EP103F
ELECTRICAL ROOF PLAN - AREA F 520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F3 ELECTRICAL ROOF PLAN - AREA F
1 EXTEND BARE COPPER WIRE TO EXISTING LIGHTNING PROTECTION
SYSTEM DOWN CONDUCTORS AS REQUIRED.
2 TIE ROOF TOP HVAC EQUIPMENT TO LIGHTNING PROTECTION
SYSTEM.
3 RELOCATED WP JUNCTION BOX FOR EXISTING SATELLITE. EXTEND
CONDUIT AND WIRE AS NEEDED TO MAINTAIN CONTINUITY.
COORDINATE RELOCATION OF SATELLITE WITH VA/COR/NAVY FOR
NAVY MIST TRAINING SYSTEM. RELOCATION SHALL RESULT IN
MINIMAL DISRUPTION OF SERVICE.
4 PROVIDE MOUNTING STRUCTURE AS REQUIRED. CONDUIT SHALL
NOT BE USED AS A SUPPORT.
5 COLD STORAGE COOLER CONDENSER.
Revisions: Date:
2022.09.23
TV
TV
TV
TV
N N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
N
E
E E
E E
E
E
E E E
E E
E
E E
E E
PA PA
PA
PA
PA PA
PA
PA
PA
PA
PA
PA
PAPA
PA
PA
J
AC
J
AC R
AC
R
R AC
D
P S
R
R
J
AC
AC
R
AC
R
AC
DPS
J
DPS AC D P
R
AC
AC
AC
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
CLNG
J
J
V
TV
V
TV
V
TV
V
S
E
TV
D
V
ES
ML
DC
CL
CR
MD
S
N
TV
N
N
P R
D
DPS
AC
D
E E
D D
C C
B B
WAITING ROOM
2G100
RESTROOM
2G100A
SPECIMEN 01
2G102
SPECIMEN 02
2G104
SPECIMEN 03
2G106
SPECIMEN 04
2G108
SPECIMEN 05
2G110
PHLEBOTOMY
2G101
RECEPTION
2G103
RESTROOM
2G112
RESTROOM
2G114
RESTROOM
2G116
SPECIMEN 08
2G105
SPECIMEN 07
2G107
SPECIMEN 06
2G109
SPECIMEN DROP OFF
2G111
SPECIMEN 09
2G113
SPECIMEN 10
2G115RESTROOM
2G118
LAB OFFICE
2G127
STAFF RESTROOM
2G126
LAB OFFICE
2G125
LAB OFFICE TOUCHDOWN
2G123
COLD STORAGE
2G121
NEG. PRESSURE LAB
MICROBIOLOGY
2G122
VESTIBULE
2G117A
STAFF RESTROOM
2G144
CONFERENCE/ BREAK ROOM
2G143
TREATMENT 1
2G135B
TREATMENT 2
2G135C TREATMENT 3
2G135D
NURSE STATION
2G135A
MED ROOM
2G142
TREATMENT 4
2G135E
TREATMENT 5
2G135F
TREATMENT 6
2G135G
TREATMENT 7
2G135H
TREATMENT 8
2G135I
TREATMENT 9
2G135J
TREATMENT 10
2G135K
INFUSION CLINIC
2G135
RESTROOM
2G139
RESTROOM
2G138
ADMIN SUPPORT
2G137
EXAM / CONSULT
2G136
CORRIDOR
C2-97
SOILED UTILITY
2G140
RECEPTION
2G134
WAITING ROOM
2G133
HAC
2G132
STERILE SUPPLY
2G119
CONSULT
2G128
CONSULT
2G129
FILE CLOSET
2G130
CORRIDOR
C2-101
ELECTRICAL
2G131
BULK STORAGE
2G120
STERILE SUPPLY
2G141
CORE LAB
2G117
CORRIDOR
C2-99
INFUSION CLINIC
2G135
CORE LAB
2G117
CORE LAB
2G117
TELECOM ROOM
2G145
3 3
4D
2D/2V
2D/2V 4D
4D
4D
4D
4D
4D
4D
4D
(TYP.)
(TYP.)
STAIR
STAIR-F
(TYP.)
L2F2 - 48
L2F2 - 48
L2F2 - 48L2F2 - 45
L2F2 - 45
L2F2 - 47
L2F2 - 47
TV
9' AFF
QMATIC TV
60" AFF
(TYP.)
TV
60" AFF
ECL2F2 - 27
HEADEND
NURSE CALL
39" AFF
39" AFF
39" AFF
39" AFF
ECL2F - 57
A. NO WORK REQUIRED IN HATCHED AREAS. ALL LIGHTING FIXTURES,
CONTROLS, POWER DEVICES, CIRCUITING AND ASSOCIATED
WIRING SHALL BE EXISTING TO REMAIN.
B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL
RATED WALLS, CEILINGS AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIALS
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILINGS AND
SLABS ASSEMBLY INSTALLED IN ACCORDANCE WITH UL FOR THE
RATED APPLICATION.
C. ELECTRICAL CONTRACTOR SHALL COORDINATE ANY WALL
MOUNTED ITEM (ELECTRICAL/DATA/LIGHT) WITH ARCHITECT PRIOR
TO INSTALLATION.
D. FINAL LOCATION OF COMMUNICATION/SECURITY DEVICES SHALL
BE COORDINATED WITH THE VA DURING WALK THROUGH PRIOR TO
ROUGH-IN.
E. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
CHARACTERISTICS AND REQUIREMENTS OF ALL SECURITY
DEVICES WITH VA PRIOR TO ORDERING AND INSTALLATION.
F. THE CONTRACTOR IS RESPONSIBLE FOR TELE/DATA CONDUIT,
WIRING, TERMINATIONS, ANY REQUIRED PATCH PANELS, ETC.
NECESSARY FOR ALL SPECIAL SYSTEMS UNLESS OTHERWISE
NOTED. INSTALL ALL CONDUITS ALL THE WAY UP TO THE CABLE
TRAY.
G. THE NURSE CALL SYSTEM SHALL BE USED FOR BID PURPOSES
ONLY. CONTRACTOR SHALL OBTAIN ACTUAL WIRING
DIAGRAM/SYSTEM FROM FINAL SELECTED VENDOR. SUBMIT SHOP
DRAWINGS TO COR FOR FINAL APPROVAL. THE CONTRACTOR
SHALL PROVIDE ALL NECESSARY DEVICES, BACKBOXES, CONDUIT,
WIRING ETC. TO PROVIDE A FULLY FUNCTIONAL SYSTEM.
H. ALL EQUIPMENT AND DEVICES ON PLAN ARE SHOWN AS NEW
UNLESS NOTED OTHERWISE INDICATED WITH AN (E).
I. FOR ALL EXAM ROOMS, OFFICES, RECEPTIONS, ETC. THAT
REQUIRE A DURESS CALL BUTTON, THESE ROOMS SHALL BE
FITTED WITH A WORK STATION THAT HAS A DURESS CALL
INTEGRATED WITHIN THE SYSTEM. COORDINATE WITH VA FOR ALL
REQUIREMENTS. CONTRACTOR SHALL PROVIDE AN ALLOWANCE
FOR DURESS CALL BUTTON IF OTHERWISE DIRECTED BY VA.
J. FOR ALL NEW PUBLIC ADDRESS SPEAKERS, THEY SHALL BE
COMPATIBLE WITH THE EXISTING PA SYSTEM, PZS 140RA. SEE
SHEET E-503 FOR ADDITIONAL INFORMATION. CONTRACTOR SHALL
TEST, PROGRAM, PROVIDE PROGRAM CARDS, CONDUITS,
ADJUSTING HARDWARE AND SOFTWARE FOR A COMPLETE
FUNCTIONAL SYSTEM.
K. ALL DATA OUTLETS SHOWN IN THE CORE LAB SHALL BE MOUNTED
ABOVE COUNTER UNLESS NOTED OTHERWISE.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
CEILING DATA OUTLET
FLOOR DATA OUTLET
FLOOR TELEPHONE OUTLET
CLNG
NURSE CALL STAFF STATION
TELEPHONE OUTLET
VOICE/DATA OUTLET
VOLUME CONTROL
CATV OUTLET
TV OUTLET
SYMBOLSYMBOL SYMBOL
ELECTRICAL SYMBOL LEGEND
DESCRIPTION DESCRIPTION DESCRIPTION
CEILING DATA OUTLET
FLOOR DATA OUTLET
(4) FOUR RJ45 OUTLET
FLOOR TELEPHONE OUTLET
CLNG
ELECTRIC STRIKE
MAGNETIC LOCK
COMBINATION LOCK
DOOR CONTACT
CARD READER
SECURITY KEYPAD
MOTION DETECTOR
NURSE CALL STAFF STATION
NURSE CALL DOME LIGHT (1-COLOR)
TELEPHONE OUTLET
VOICE/DATA OUTLET
DOOR BELL
DOOR BUZZER
DOOR CHIME
DOOR SIGNAL
VOLUME CONTROL
CATV OUTLET
TV OUTLET
NURSE CALL DOME LIGHT (4-COLORS)
NURSE CALL DOME LIGHT (2-COLORS)
AUTO DOOR PUSH PAD
NURSE CALL EMERGENCY STATION
NURSE CALL MASTER STATION
360 DEGREES SECURITY CAMERA
FIXED SECURITY CAMERA
PUSHBAR TO EXIT
REQUEST TO EXIT
DUAL AUTHENTICATION
ACCESS CONTROL
DOOR POSITION SWITCH
DURESS ALARM BUTTON
N
SEC 6
(F)
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:4
P
M
EY102F
ELECTRICAL SPECIAL SYSTEMS SECOND FLOOR
PLAN - AREA F
520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F3 ELECTRICAL SPECIAL SYSTEMS SECOND FLOOR PLAN - AREA F
1 PROVIDE (1) 1" CONDUIT FOR LOW VOLTAGE WIRING THROUGH
WALL.
2 PROVIDE (1) 1-1/2" CONDUIT FOR LOW VOLTAGE WIRING THROUGH
FIRE RATED WALL.
3 PROVIDE (1) 2-1/2" CONDUIT FOR LOW VOLTAGE WIRING THROUGH
FIRE RATED WALL.
4 PROVIDE (11) 4" CONDUITS FOR LOW VOLTAGE WIRING THROUGH
FIRE RATED WALL.
5 2"Dx2"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
6 2"Dx4"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
7 2"Dx6"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
8 2"Dx12"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
9 2"Dx20"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
10 4"Dx16"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
11 4"Dx18"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
12 4"Dx20"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH ABOVE CEILING UTILITIES.
13 AUTOMATIC DOOR OPENER. IN ADDITION TO THE CEILING MOUNTED
JUNCTION SHOWN ON DRAWINGS, INSTALL CONDUIT STUBBED UP
INTO CEILING SPACE WITH PULL STRING. LOCATION SHALL BE
COORDINATED WITH COR. CONTRACTOR SHALL COORDINATE
EXACT REQUIREMENTS WITH COR SECURITY VENDOR AND DOOR
HARDWARE MANUFACTURER. ACCOUNT FOR ALL REQUIRED
PROVISIONS PRIOR TO BID ISSUANCE.
14 PROVIDE PUBLIC ADDRESS SPEAKER WITH LOCAL VOLUME
CONTROLS.
15 REMISOL WORKSTATIONS - PROVIDE ENDPOINT CONNECTION TO
LAB EQUIPMENT E5 AND E6. REMISOL WORKSTATION SHALL TIE
BACK TO REMISOL SERVER STATION LOCATED IN ROOM 2G123.
VERIFY ALL CONNECTIONS WITH COR.
16 REMISOL WORKSTATIONS - PROVIDE ENDPOINT CONNECTION TO
LAB EQUIPMENT E15 AND E16. REMISOL WORKSTATION SHALL TIE
BACK TO REMISOL SERVER STATION LOCATED IN ROOM 2G123.
VERIFY ALL CONNECTIONS WITH COR.
17 EQUIPMENT TO BE CONNECTED TO REMISOL WORKSTATION. SEE
EQUIPMENT PLAN FOR ADDITIONAL INFORMATION.
18 PROVIDE DATA OUTLET FOR STAT BOARD MOUNTED 72" AFF.
REMISOL SHALL BE COMMUNICATE WITH STAT BOARD. COORDINATE
ALL REQUIREMENTS WITH EQUIPMENT VENDOR.
19 (2) 4-POST RACKS WITH 48 PORT PATCH PANELS AND UPS. SEE
COMMUNICATION SYSTEM RISER DIAGRAM FOR ADDITIONAL
INFORMATION ON SHEET E-503.
20 PROVIDE (5) 4" CONDUITS FOR LOW VOLTAGE WIRING THROUGH
FIRE RATED WALL.
21 FLOOR OUTLET FOR PILLOW SPEAKER AT CHAIR LOCATION.
COORDINATE ALL REQUIREMENTS WITH VA PRIOR TO
INSTALLATION.
22 CEILING MOUNTED JUNCTION BOX FOR QMATIC NUMBERING
SYSTEM. SYSTEM SHALL REPORT TO RECEPTION COMPUTER IN
ROOM 2G103 AND BE DISPLAYED ON THE QMATIC TV LOCATED IN
WAITING ROOM 2G100. COORDINATE ALL REQUIREMENTS WITH VA
PRIOR TO INSTALLATION. PROVIDE LOW VOLTAGE TRANSFORMER
AS REQUIRED.
23 REMOTE RELEASE PUSH BUTTON. COORDINATE EACH LOCATION
WITH VA PRIOR TO INSTALLATION.
24 6"Dx20"W LADDER TYPE CABLE TRAY. COORDINATE MOUNTING AND
ROUTING WITH CEILING UTILITIES.
Revisions: Date:
2022.09.23
Q.8 Q.8
Q Q
P P
N N
M M
L L
K K
Q.9 Q.9
CT-3
EQDP - 49,51,53
DPHB - 1
200/NF/1
MECHANICAL ROOM
1B179
CH-3
(E)CH-2(E)CH-1
CWP-1.3
DPM - 67,69,71
(E)CT-2
(E)CT-1
VFD-CT-3VFD-CWP-1.3
MSB-A - 5
HWP-1.1
HWP-1.2
DPM - 68,70,72
CHWP-2.3
DPM - 62,64,66
A. NO WORK REQUIRED IN HATCHED AREAS. ALL LIGHTING FIXTURES,
CONTROLS, POWER DEVICES, CIRCUITING AND ASSOCIATED
WIRING SHALL BE EXISTING TO REMAIN.
B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL
RATED WALLS, CEILINGS AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIALS
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILINGS AND
SLABS ASSEMBLY INSTALLED IN ACCORDANCE WITH UL FOR THE
RATED APPLICATION.
C. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL
EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO
ORDERING AND INSTALLATION.
D. ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER AND
CONNECTION REQUIREMENTS FOR ALL EQUIPMENT PRIOR TO
ORDERING AND INSTALLATION. VERIFY ALL DEVICE LOCATION AND
MOUNTING HEIGHT. MAKE ADJUSTMENT IN FIELD TO MATCH
ACTUAL EQUIPMENT NAMEPLATE BEING INSTALLED.
E. ALL CONTROL WIRING SHALL BE INCLUDED AS PART OF THE
MECHANICAL WORK. MECHANICAL CONTRACTOR SHALL ENSURE
THAT ELECTRICAL INTERFACE DEVICES THAT ARE NECESSARY IN
THE ELECTRICAL COMPONENT ARE COORDINATED WITH THE
ELECTRICAL CONTRACTOR.
F. ALL WIRING FROM LOAD SIDE OF VFD TO CONNECTION AT
EQUIPMENT SHALL BE XLPE (XHHW-2) INSTALLED IN ACCORDANCE
WITH EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
N
SEC 2
(B)
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:5
P
M
EM101B
MECHANICAL POWER GROUND FLOOR PLAN -
AREA B
520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F2 MECHANICAL POWER GROUND FLOOR PLAN - AREA B
1 VSD AND DISCONNECT FACTORY INSTALLED.
2 ROUTE CONDUIT TO SUPPLY SIDE OF NEW NEMA 3R VFD WITH INTEGRAL
DISCONNECT FOR COOLING TOWER. PROVIDE XLPE WIRE (XHHW-2) FROM
VFD LOAD SIDE TERMINAL TO COOLING TOWER. VERIFY EXACT LOCATION
OF VFD WITH MECHANICAL CONTRACTOR.
3 ROUTE CONDUIT TO SUPPLY SIDE OF NEW NEMA 3R VFD WITH INTEGRAL
DISCONNECT FOR CWP-1.3. PROVIDE XLPE WIRE (XHHW-2) FROM VFD
LOAD SIDE TERMINAL TO PUMP. VERIFY EXACT LOCATION OF VFD WITH
MECHANICAL CONTRACTOR.
DEDUCTIVE ALTERNATES
D1 DEDUCTIVE ALTERNATE #1: REMOVE ALL SCOPE OF WORK ASSOCIATED
WITH ~51,200 SF OF NEW PARKING. SEE GI100.
D2 DEDUCTIVE ALTERNATE #2: REMOVE ALL SCOPE OF WORK ASSOCIATED
WITH ~39,000 SF OF NEW PARKING. SEE GI100.
D3 DEDUCTIVE ALTERNATE #3: REDUCE WINDOW QUANTITY BY 8. SEE
A-201.
D4
DEDUCTIVE ALTERNATE #4: REMOVE ALL SCOPE ASSOCIATED
WITH 600 TON CHILLER (CH-3) REPLACEMENT IN MECHANICAL
ROOM 1B179.
NOTE: DEDUCTIVE ALTERNATES ARE CASCADING. EACH DEDUCT WILL BE TAKEN IN
SUCCESSION AND SHALL BE PRICED UNDER SEQUENTIAL, SEPARATE CLINs
(CONTRACT LINE ITEM NUMBER) SO DETERMINATIONS CAN BE MADE AND
PRIORITIES ESTABLISHED BASED ON BIDS RECEIVED.
D4
Revisions: Date:
2022.09.23
M M M M
M
M
M
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M
M M
M
M
E E
D D
C C
B B
CONSULT
2G128
CONSULT
2G129
FILE CLOSET
2G130
ELECTRICAL
2G131
CORRIDOR
C2-101
LAB OFFICE
2G127
STAFF RESTROOM
2G126
LAB OFFICE
2G125
LAB OFFICE TOUCHDOWN
2G123
RESTROOM
2G118
SPECIMEN 10
2G115
SPECIMEN 09
2G113
RESTROOM
2G116
RESTROOM
2G114
SPECIMEN DROP OFF
2G111
COLD STORAGE
2G121
BULK STORAGE
2G120
STERILE SUPPLY
2G119
HAC
2G132
NEG. PRESSURE LAB
MICROBIOLOGY
2G122
STERILE SUPPLY
2G141
WAITING ROOM
2G133
CORE LAB
2G117
SPECIMEN 06
2G109
SPECIMEN 07
2G107
SPECIMEN 08
2G105
RECEPTION
2G103
WAITING ROOM
2G100
PHLEBOTOMY
2G101
RESTROOM
2G100A
SPECIMEN 01
2G102
SPECIMEN 02
2G104
SPECIMEN 03
2G106
SPECIMEN 04
2G108
SPECIMEN 05
2G110
CONFERENCE/ BREAK ROOM
2G143
CORRIDOR
C2-99
VESTIBULE
2G117A STAFF RESTROOM
2G144
TREATMENT 1
2G135B
TREATMENT 2
2G135C
TREATMENT 3
2G135D
NURSE STATION
2G135A
TREATMENT 4
2G135E
TREATMENT 5
2G135F
MED ROOM
2G142
TREATMENT 6
2G135G
TREATMENT 7
2G135H
TREATMENT 10
2G135K
TREATMENT 8
2G135I
TREATMENT 9
2G135J
INFUSION CLINIC
2G135
SOILED UTILITY
2G140
RESTROOM
2G139
RESTROOM
2G138
ADMIN SUPPORT
2G137
RECEPTION
2G134 EXAM / CONSULT
2G136
CORRIDOR
C2-97
RESTROOM
2G112
CORE LAB
2G117
TELECOM ROOM
2G145
DSSI-2G131
EAV-2F-2G119
SAV-2F-2G119
RH-2F-2G119
ATU-2F-C2-97
ATU-2F-2G130 ATU-2F-2G133
ATU-2F-2G145
SAV-2F-2G141
ATU-2F-2G129
ATU-2F-2G128
ATU-2F-2G127
ATU-2F-2G125
ATU-2F-2G123
ATU-2F-2G115
ATU-2F-2G126
ATU-2F-2G113
SAV-2F-2G122
ATU-2F-2G120
ATU-2F-2G112
ATU-2F-2G111
ATU-2F-2G105
ATU-2F-2G103
ATU-2F-2G100
ATU-2F-2G101
ATU-2F-2G107
ATU-2F-2G109
ATU-2F-2G100A
ATU-2F-2G102 ATU-2F-2G104 ATU-2F-2G106 ATU-2F-2G108
ATU-2F-2G110
ATU-2F-2G143
ATU-2F-2G144
ATU-2F-2G135-1
ATU-2F-2G135-3
ATU-2F-2G142
ATU-2F-2G135
ATU-2F-2G138
ATU-2F-2G140
ATU-2F-2G134
ATU-2F-2G137
EAV-2F-2G122
ATU-2F-2G136
DSSI-2G145
L2F - 9
L2F - 11
L2F - 15
L2F - 13
EAV-2F-2G117
SAV-2F-2G117-2
SAV-2F-2G117-3 ATU-2F-2G135-2
RH-2F-2G117-1
A. NO WORK REQUIRED IN HATCHED AREAS. ALL LIGHTING FIXTURES,
CONTROLS, POWER DEVICES, CIRCUITING AND ASSOCIATED
WIRING SHALL BE EXISTING TO REMAIN.
B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL
RATED WALLS, CEILINGS AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIALS
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILINGS AND
SLABS ASSEMBLY INSTALLED IN ACCORDANCE WITH UL FOR THE
RATED APPLICATION.
C. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL
EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO
ORDERING AND INSTALLATION.
D. ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER AND
CONNECTION REQUIREMENTS FOR ALL EQUIPMENT PRIOR TO
ORDERING AND INSTALLATION. VERIFY ALL DEVICE LOCATION AND
MOUNTING HEIGHT. MAKE ADJUSTMENT IN FIELD TO MATCH
ACTUAL EQUIPMENT NAMEPLATE BEING INSTALLED.
E. ALL CONTROL WIRING SHALL BE INCLUDED AS PART OF THE
MECHANICAL WORK. MECHANICAL CONTRACTOR SHALL ENSURE
THAT ELECTRICAL INTERFACE DEVICES THAT ARE NECESSARY IN
THE ELECTRICAL COMPONENT ARE COORDINATED WITH THE
ELECTRICAL CONTRACTOR.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
N
SEC 6
(F)
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:0
P
M
EM102F
MECHANICAL POWER SECOND FLOOR PLAN -
AREA F
520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F3 MECHANICAL POWER SECOND FLOOR - AREA F
1 PROVIDE 3/4" CONDUIT WITH POWER AND CONTROLS FOR SPLIT SYSTEM
EVAPORATOR. MAKE CONNECTIONS PER MANUFACTURER.
Revisions: Date:
2022.09.23
K K
J J
H H
G G
F F
LPH
T-HPH
HPH
DPPH - 20,22,24
DPPH - 2,4,6
LPH - 13
30/NF/1
100/NF/1
ECH2CA
AHU-3 (E)
AHU-2 (E)
AHU-5 (E)
(E)GEF-31
(E)GEF-1
GEF-4B(E)
AHU-2-N
(E)GEF-4A
(E)GEF-5
DPPH
LPH - 10
DDC CONTROLLER
LPH - 15
AHU-2-N PUMP 3
A. NO WORK REQUIRED IN HATCHED AREAS. ALL LIGHTING FIXTURES,
CONTROLS, POWER DEVICES, CIRCUITING AND ASSOCIATED
WIRING SHALL BE EXISTING TO REMAIN.
B. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY ALL
RATED WALLS, CEILINGS AND SLABS AND THEIR SPECIFIED RATING
ON THE ARCHITECTURAL DRAWINGS. ALL DEVICES AND MATERIALS
SHALL MEET THE UL RATING OF THE RATED WALLS, CEILINGS AND
SLABS ASSEMBLY INSTALLED IN ACCORDANCE WITH UL FOR THE
RATED APPLICATION.
C. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL
CHARACTERISTICS AND REQUIREMENTS OF ALL MECHANICAL
EQUIPMENT WITH MECHANICAL CONTRACTOR PRIOR TO
ORDERING AND INSTALLATION.
D. ELECTRICAL CONTRACTOR SHALL VERIFY ALL POWER AND
CONNECTION REQUIREMENTS FOR ALL EQUIPMENT PRIOR TO
ORDERING AND INSTALLATION. VERIFY ALL DEVICE LOCATION AND
MOUNTING HEIGHT. MAKE ADJUSTMENT IN FIELD TO MATCH
ACTUAL EQUIPMENT NAMEPLATE BEING INSTALLED.
E. ALL CONTROL WIRING SHALL BE INCLUDED AS PART OF THE
MECHANICAL WORK. MECHANICAL CONTRACTOR SHALL ENSURE
THAT ELECTRICAL INTERFACE DEVICES THAT ARE NECESSARY IN
THE ELECTRICAL COMPONENT ARE COORDINATED WITH THE
ELECTRICAL CONTRACTOR.
F. ALL WIRING FROM LOAD SIDE OF VFD TO CONNECTION AT
EQUIPMENT SHALL BE XLPE (XHHW-2) INSTALLED IN ACCORDANCE
WITH EQUIPMENT MANUFACTURER'S SPECIFICATIONS.
G. FOR AHU-2-N, A DUCT SMOKE DETECTOR IS REQUIRED. DUCT
SMOKE DETECTOR SHALL BE PROVIDED BY MECHANICAL AND
WIRED BY ELECTRICAL. COORDINATE ALL REQUIREMENTS WITH
MECHANICAL PRIOR TO INSTALLATION.
KEYNOTES
KEY PLAN
GENERAL SHEET NOTES
N
JACC KEYPLAN
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o n s tr u c t R e n o v a ti o n a n d
A d d it io n t o
J A
C C
P e n s a c o la /5
-2
.J
A C
C .P a c k a g e .M
E P
F
R
.r v t
/2
/2
:0
:1
P
M
EM103P
MECHANICAL POWER THIRD FLOOR PLAN -
PENTHOUSE NORTH
520-331
JACC-2F
09.26.2022 JR SC
ISSUED FOR
CONSTRUCTION
CONSTRUCT ADDITION AND
RENOVATIONS TO JACC
790 Veterans Way, Pensacola, FL 32503
1/8" = 1'-0"F3 MECHANICAL POWER THIRD FLOOR PLAN - PENTHOUSE NORTH
1 HUMIDITY GENERATOR AND LIGHTING/RECEPTACLE DISCONNECTS
SHALL BE PROVIDED BY GENERAL CONTRACTOR. COORDINATE
MOUNTING WITH MANUFACTURER DURING INSTALLATION.
2 VFD AND DISCONNECT FACTORY INSTALLED.
3 AHU-2-N- PUMP. COORDINATE EXACT LOCATION WITH MECHANICAL
PRIOR TO INSTALLATION.
Revisions: Date:
2022.09.23
SECTION A-A
A
A
GROUNDING DETAIL
GROUND
BAR
NEUTRAL
BAR
CATV FA SEC
ELEC
METER
GROUND
BAR
NEUTRAL
BAR
TWO HOLE STRAP OR
CADWELD CONNECTION TYPE
''LK'', TYPICAL
MOUNTING BRACKETS
FIBERGLASS INSULATORS
4"
MIN.
NOTES:
1. PREDRILLED BOLT HOLE SIZE AND SPACING AS REQUIRED FOR INDICATED TERMINATIONS .
2. PROVIDE LENGTH SUFFICIENT FOR ALL INDICATED TERMINATIONS AND 20% SPARE MOUNTING
SPACE. CONNECTIONS SHALL UTILIZE TWO HOLE COMPRESSIONS CONNECTOR.
3. GROUND BAR SHALL BE MOUNTED MINIMUM 2" OFF WALL AND 12" AFF.
4. FIBERGLASS INSULATORS SHALL HAVE A MINIMUM DIELECTRIC STRENGTH OF 15kV.
INSULATED COPPER
GROUND CONDUCTOR TO
BUILDING GROUNDING
ELECTRODE CONDUCTOR
GROUND BUS DETAIL
NOTES:
1. TYPICAL FOR WOOD AND METAL STUD ROUGH-IN.
2. PLASTER RINGS NOT SHOW.
3. LOCATE ALL OUTLET BOXES IN ACCORDANCE WITH ARCHITECTURAL AND
MECHANICAL DRAWINGS, AND WITH ALL APPLICABLE SHOP DRAWINGS.
4. IN ACCORDANCE WITH UBC 4304 OUTLETS ON OPPOSITE SIDES OF WALLS OR
PARTITIONS IN THE SAME STUD SPACE MUST BE SEPARATED BY A MIN. OF 24"
HORIZONTAL DISTANCE.
5. TOENAILING OF OUTLET BOXES DIRECTLY TO THE STUDS WILL NOT BE
ACCEPTED.
6. OUTLETS SHOWN TOGETHER ON PLAN SHALL BE INSTALLED TOGETHER.
TYPICAL
WALL
OUTLETS
PROVIDE CONDUIT SUPPORTS IN
ACCORDANCE WITH NEC. SPACING
REQUIREMENTS FOR TYPE OF RACEWAY
REQUIRED.
AS REQUIRED FOR TYPE
OF CONSTRUCTION.
BOX
SUPPORT
TYPICAL
OUTLET
BOX.
TYPICAL ROUGH-IN
61_
MIN.
DEDICATED
ELECTRICAL
SPACES
PERMITTED
LUMINARIE
PERMITTED
PERMITTED
STRUCTURAL
CEILING
SUSPENDED
CEILING
SIDE VIEW FRONT
6' OR
LESS
DEDICATED EQUIPMENT SPACE NOTES:
1. THE SPACE EQUAL TO THE WIDTH AND DEPTH OF THE EQUIPMENT AND EXTENDING
FROM THE FLOOR TO A HEIGHT OF 6'-0" ABOVE THE EQUIPMENT OR TO THE
STRUCTURAL CEILING, WHICHEVER IS LOWER, SHALL BE DEDICATED TO THE
ELECTRICAL INSTALLATION. NO PIPING, DUCTS, LEAK PROTECTION APPARATUS OR
OTHER EQUIPMENT FOREIGN TO THE ELECTRICAL INSTALLATION SHALL BE
LOCATED IN THIS ZONE.
2. THE AREA ABOVE THE DEDICATED SPACE SHALL BE PERMITTED TO CONTAIN
FOREIGN SYSTEMS, PROVIDED PROTECTION IS INSTALLED TO AVOID DAMAGE TO
THE ELECTRICAL EQUIPMENT FROM CONDENSATION, LEAKS, OR BREAKS IN SUCH
FOREIGN SYSTEMS.
3. SPRINKLER PROTECTION SHALL BE PERMITTED FOR THE DEDICATED SPACE WHERE
THE PIPING COMPLIES WITH THESE NOTES.
4. A DROPPED, SUSPENDED, OR SIMILAR CEILING THAT DOES NOT ADD STRENGTH TO
THE BUILDING STRUCTURE SHALL NOT BE CONSIDERED A STRUCTURAL CEILING.
DEDICATED ELECTRICAL SPACES ELECTRICAL EQUIPMENT NAMEPLATE PENETRATIONS THROUGH RATED WALLS
C6
NTS
D7
NTS
D6
NTS
F9
NTS
F6
NTS
F7
NTS
1. Wall Assembly — The 1 or 2 hr fire-rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300, U400, V400 or W400 Series Wall and Partition Designs in the UL Fire Resistance Directory and shall include the following construction features:
A. Studs — Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 in. (51 mm) by 4 in.
(102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 2-1/2 in. (64 mm) wide and spaced max 24 in. (610 mm) OC.
Additional studs installed to completely frame the opening.
B. Gypsum Board* — 5/8 in. (16 mm) thick, 4 ft (1219 mm) wide with square or tapered edges. The gypsum board type, thickness, number of layers, fastener type and sheet orientation shall be as specified in the individual Wall and Partition Design. Max area of opening is 352 sq in. (2271 sq cm) with max dimension of 22 in. (559 mm) wide.
The hourly F and FH Ratings of the firestop system are equal to the hourly fire rating of the wall assembly in which it is installed.
2. Cable Tray* — Max 18 in. (457 mm) wide by max 6 in. (152 mm) deep open-ladder or solid-back cable tray with channel-shaped side rails formed of 0.065 in. (1.65 mm) thick aluminum or 0.060 in. (1.52 mm) thick steel and with 1-1/2 in. (38 mm) wide by 1 in. (25 mm) channel shape rungs spaced 9 in. (229 mm) OC or a 0.029 in. (0.74 mm) thick steel solid back, respectively. One cable tray to be installed in the opening. The max annular space between the cable tray and the periphery of the opening shall be min 1 in. (25 mm) to max 7 in. (178 mm) Cable tray to be rigidly supported on both sides of floor or wall assembly.
3. Cables — Aggregate cross-sectional area of cables in cable tray to be max 30 percent of the cross-sectional area of the cable tray.
Any combination of the following types and sizes of copper conductor cables may be used:
A. 7/C No. 12 AWG with polyvinyl chloride (PVC) insulation and PVC jacket.
B. 100 pair - No. 24 AWG cable with PVC insulation and jacket.
C. 1/C, 750 kcmil (or smaller) with PVC insulation and jacket.
4. Through-Penetrants — One or more pipe or tube to be installed within the opening. The total number of through-penetrants is dependent on the size of the opening and types and sizes of the penetrants. Any combination of the penetrants described below may be used provided that the following parameters relative to the annular spaces and the spacings between the pipes are maintained. The space between the pipe or tube and the periphery of the opening shall be min 1-1/2 in. (38 mm) to max 9-1/4 in. (235 mm). Pipe or tube to be rigidly supported on both sides of floor or wall assembly. The following types and sizes of non-metallic or metallic pipes, or tubes may be used:
A. Polyvinyl Chloride (PVC) Pipe — Max 3 in. (76 mm) diam Schedule 40 solid core PVC pipe (or smaller) for use in closed (process or supply) or vented (drain, waste or vent) piping system.
B. Steel Pipe — Nom 6 in. (152 mm) diam (or smaller) Schedule 40 (or heavier) steel pipe.
C. Conduit — Nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing or 6 in. (152 mm) diam steel conduit.
D. Copper Pipe — Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe.
E. Copper Tube — Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tube.
4A. Pipe Covering — (Not Shown) Nom 1-1/2 in. (38 mm) thick hollow cylindrical heavy density (min 3.5 pcf) (56kg/m3) glass fiber units jacketed on the outside with an all service jacket. Longitudinal joints sealed with metal fasteners or factory applied self-sealing lap tape.
Transverse joints secured with metal fasteners or with butt tape supplied with the product.
See Pipe and Equipment Covering and Materials (BRGU) category in the Building Materials Directory for names of manufacturers. Any pipe covering material meeting the above specifications and bearing the UL Classification Marking with a Flame Spread Index of 25 or less and a Smoke Developed Index of 50 may be used.
5. Cables — Max 1-1/2 in. (38 mm) diam tight bundle of cables installed within the opening and rigidly supported on both surfaces of wall. The space between the cables and periphery of the opening shall range from 1-3/16 in. (30.2 mm) min to a max of 1-1/2 in. (38 mm). Any combination of the following types and sizes of cables may be used:
A. 7/C No. 12 AWG with polyvinyl chloride (PVC) insulation and jacket.
B. 25 pair — No. 24 AWG cable with PVC insulation and jacket.
C. Type R GU/59 coaxial cable with PVC outer jacket.
D. 24 fiber optic cable with PVC sub unit and outer jacket.
6. Firestop System — The firestop system shall consist of the following:
A. Fill, Void or Cavity Material* — Fire Blocks For walls incorporating max 3-5/8 in. (92 mm) steel studs or max 2 (51 mm) by 4 in.
(102 mm) wood studs, fire block installed with 5 in. (127 mm) dimension projecting through and centered in opening. For walls constructed of larger steel or wood studs, fire block installed with long dimension passing through and centered in opening. Blocks may or may not be cut flush with both surfaces of wall. When multiple layers of gypsum board are used, blocks may be recessed 1/2
in. (13 mm) from surface of wall. Blocks to be firmly packed in opening. Either one or a combination of the block types specified below may be used.
B. Fill, Void or Cavity Material* — Sealant or Putty - Fill material to be forced into interstices of cables, between cables and cable trays, around each penetrant and where obvious voids are observed to max extent possible on both surfaces of the penetration.
GROUNDING DETAIL KEYNOTES
1. GROUND BUS BAR LOCATED IN MAIN ELECTRICAL ROOM OR WITHIN
SERVICE ENTRANCE MAIN. 0.25" X 4" X 12" WITH 18 HOLES MINIMUM FOR
EXTERNAL INSTALLATION.
2. GROUNDING TRIAD, 3-3/4" X 10'-0" COPPERCLAD GROUND RODS DRIVEN
INTO GROUND AT LEAST 1 ROD'S LENGTH APART. PROVIDE WITH
INSPECTION TEST WELL.
3. COPPER GROUNDING ELECTRODE CONDUCTOR SIZED PER NEC TABLE
250.66, MINIMUM SIZE #8.
4. SERVICE ENTRANCE MAIN BONDING JUMPER SIZED PER NEC TABLE
250.66. NEUTRAL SHALL ONLY BE BONDED AT SERVICE ENTRANCE, ALL
OTHER NEUTRALS SHALL BE CONSIDERED FLOATING.
5. CONNECTIONS TO BUILDING STEEL SHALL BE BY EXOTHERMIC WELD.
6. CONNECTIONS TO REBAR ENCASED IN CONCRETE SHALL BE BY
EXOTHERMIC WELD.
7. BOND METALLIC COLD WATER PIPE WITHIN 5' - 0" OF ENTERING
BUILDING. CONNECTION SHALL BE MADE WITH NON-CORROSIVE
MATERIAL GROUNDING ELECTRODE CLAMP.
8. SERVICE ENTRANCE NEUTRAL CONDUCTOR.
9. ALL EQUIPMENT ENCLOSURES AND METAL RACEWAYS SHALL BE
GROUNDED WITH AN EQUIPMENT GROUNDING CONDUCTOR SIZED PER
NEC TABLE 250.122.
10. EQUIPMENT GROUNDING CONDUCTOR SIZED PER NEC TABLE 250.122.
11. NEUTRAL CONDUCTOR WITH INSULATED EQUIPMENT GROUNDING
CONDUCTOR TO BRANCH CIRCUIT PANELS/EQUIPMENT.
12. ALL TELECOM ROOMS SHALL HAVE A GROUNDING BUS BAR. TIE INTO
MAIN ELECTRICAL ROOMS MAIN SYSTEM USING, AT MINIMUM, AWG #8
COPPER.
X
SERVICE ENTRANCE MAIN
BRANCH CIRCUIT PANEL
GRADE
3 3 3
TO UPPER FLOORS, REMOTE
ELECTRICAL ROOMS, IT CLOSETS
WHERE APPLICABLE
HEM
120/208V, 3PH, 4W
FED FROM MSB BKR. 11
SCA 36,921A 01/03/12
LETTER (FILL) COLOR
EMERGENCY = WHITE
NORMAL - WHITE
INDICATED
VOLTAGE,
NO. OF PHASES,
NO OF WIRES
INDICATES WHERE
THIS EQUIPMENT IS
FED FROM
(TRANSFER
SWITCHES WILL HAVE
TWO LINES.)
CALCULATED
AVAILABLE FAULT
CURRENT
ATTACH
NAMEPLATE
WITH 2 SCREWS
NAMEPLATE COLOR
LIFE SAFETY - YELLOW
CRITICAL - ORANGE
EQUIPMENT - GREEN
NORMAL - BLACK
EMERGENCY - RED
LETTERING
SHALL BE
1/4" HIGH
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT
321 4 5 6 7 8 9 10
TRIPLE C THE A&E GROUP
4830 W. Kennedy Blvd. Suite 600 Tampa, FL 33609
(813) 261 1023
MAT PERKINS
B
IM
/5
-3
C o…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .