This document outlines a solicitation for construction services to renovate the second floor of Building 101 at the National Institute of Standards and Technology. Key details include a construction magnitude between $1-5 million to convert the existing floor layout to a less restricted design with closed offices, conference rooms, open work areas, and exposed file and copy spaces. A mandatory site visit is scheduled for January 22, 2024 between 10am-12pm EST for offerors to conduct preliminary surveys. Attendees must register by January 17. Questions are due by January 29 and offers are due February 27. Required attachments provide building plans, specifications, asbestos inventory and mechanical/electrical scope.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ACM INVENTORY SUMMARY - SORTED BY ROOM THEN MATERIAL
NIST MD - Administration Building
Level ID 1 Description 1st Level
Room_ID 1XR1 Description 1st Level Main Roof
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability RFL01 Silver coated black tar roof flashing - N Wall - E Wall -
S Wall - W Wall 2186 Good
LowNF I
PACMLF
RSH01 Gray asphaltic roof sheeting and associated tar and felt Floor 154230 Good
LowNF I
PACMSF
Room_ID A101 Description Men's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
480 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 200 Good
LowNF II
PACMSF
Room_ID A103 Description Janitor's Closet
No ACM Found.
Room_ID A104 Description Fire Protection Storage Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC16 9 inch by 9 inch black floor tile with white streaks and associated mastic Floor 48 Good
LowNF I
PACMSF
Room_ID A105 Description Women's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
480 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 200 Good
LowNF II
PACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black)
- Other 2 Good
LowF
ACMEA
Room_ID A106 Description Electrical Closet
No ACM Found.
Date Printed: 4/28/2022
Room_ID A108 Description Conference Room
No ACM Found.
Room_ID A116 Description Exterior Storage
No ACM Found.
Room_ID A118 Description Exterior Storage Room
No ACM Found.
Room_ID A120 Description Telephone Closet
No ACM Found.
Room_ID A121 Description Work Station Suite (irregular Shape Sue To Office Cubes)
No ACM Found.
Room_ID A122 Description Electrical Closet
No ACM Found.
Room_ID A123 Description Reception
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability DS03 Black duct sealant at seams of foil wrapped fiberglass duct insulation
- Other 20 Good
LowNF II
ACMSF
Room_ID A123-1 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 110 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 1 Good
LowNF II
ACMEA
Room_ID A123-10 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-11 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-12 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-13 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-14 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-15 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 231 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-2 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-26 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 64 Good
LowNF II
ACMSF
Room_ID A123-28 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 64 Good
LowNF II
ACMSF
Room_ID A123-28A Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 72 Good
LowNF II
ACMSF
Room_ID A123-3 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-36 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 88 Good
LowNF II
ACMSF
Room_ID A123-39 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 77 Good
LowNF II
ACMSF
Room_ID A123-4 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-5 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-6 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation - not observed
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-7 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation - not observed
Floor 88 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-8 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 77 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A123-9 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 130 Good
LowNF II
ACMSF
MA07 Remnant black floor tile adhesive
Limited observation - not observed
Floor 121 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 2 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A125 Description Work Station Suite
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Sporadic observation
Floor 1176 Good
LowNF II
ACMSF
Room_ID A129 Description Work Station Suite
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Sporadic observation
Floor 2378 Good
LowNF II
ACMSF
Room_ID A131 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 187 Good
LowNF II
ACMSF
Room_ID A133 Description Conference Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA07 Remnant black floor tile adhesive
Limited observation under carpet - assumed throughout
Floor 187 Good
LowNF II
ACMSF
Room_ID B100 Description Small Lobby
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 1755 Good
LowNF II
PACMSF
Room_ID B101 Description Lecture Room
No ACM Found.
Room_ID B102 Description Lecture Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 1271 Good
LowNF I
ACMSF
Room_ID B103 Description Audio/Video Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile Upper 4' on walls
- N Wall - S Wall - W Wall
272 Good
LowNF II
ACMSF
FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic
Floor 276 Good
ModerateNF I
ACMSF
Room_ID B105 Description Network Room For Lecture Rooms
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 120 Good
LowNF I
ACMSF
Room_ID B106 Description Lecture Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CHB01 Black chalkboard - Other 1 Good
LowNF II
PACMEA
Room_ID B107 Description Lecture Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CHB01 Black chalkboard - Other 1 Good
LowNF II
PACMEA
Room_ID B108 Description Electrical Closet
No ACM Found.
Room_ID B109 Description Electrical Closet
No ACM Found.
Room_ID B110 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 168 Good
LowNF I
ACMSF
Room_ID B110A Description Office Vestibule
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 108 Good
LowNF I
ACMSF
Room_ID B111 Description Conference Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CHB01 Black chalkboard - Other 1 Good
LowNF II
PACMEA
Room_ID B112 Description Storage Closet
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 45 Good
LowNF I
ACMSF
Room_ID B113 Description Conference Room
No ACM Found.
Room_ID B114 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 391 Good
LowNF I
ACMSF
Room_ID B115 Description Men's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA10 Adhesive/grout associated with 2" by 10" ceramic wall tile
- N Wall - E Wall - S Wall - W Wall
464 Good
LowNF II
PACMSF
OT06 Grout associated with grey 1" by 2" ceramic floor tile Floor 208 Good
LowNF II
PACMSF
Room_ID B116 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 391 Good
LowNF I
ACMSF
Room_ID B117 Description Women's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA10 Adhesive/grout associated with 2" by 10" ceramic wall tile
- N Wall - E Wall - S Wall - W Wall
544 Good
LowNF II
PACMSF
OT06 Grout associated with grey 1" by 2" ceramic floor tile Floor 288 Good
LowNF II
PACMSF
Room_ID B118 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic Under carpet
Floor 252 Good
LowNF I
ACMSF
Room_ID B119 Description Janitor's Closet
No ACM Found.
Room_ID B121 Description Green Auditorium
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CDW06 Drywall and associated joint compound associated with
Green and Red Auditorium main and acoustical ceilings Acoustical ceiling and main ceiling
- Ceiling - Other 7032 Good
LowF
PACMSF
Room_ID B122 Description Auditorium Vestibule
No ACM Found.
Room_ID B123 Description Projection Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile Upper 4' on walls
- N Wall - S Wall - W Wall
299 Good
LowNF II
ACMSF
Room_ID B124 Description Auditorium Vestibule
No ACM Found.
Room_ID C100 Description Lecture Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 6 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 5 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 5 Good
LowNF II
ACMEA
Room_ID C102 Description Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
272 Good
ModerateNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 72 Good
LowNF II
PACMSF
Room_ID C102A Description Restroom Vestibule
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
144 Good
ModerateNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 20 Good
LowNF II
PACMSF
Room_ID C105 Description Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
256 Good
ModerateNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 63 Good
LowNF II
PACMSF
Room_ID C105A Description Restroom Vestibule
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
112 Good
ModerateNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 12 Good
LowNF II
PACMSF
Room_ID C106 Description Conference Dining Room (includes C108)
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 6 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 6 Good
LowNF II
ACMEA
Room_ID C107 Description Storage Closet
No ACM Found.
Room_ID C109 Description Storage (old kitchen area)
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
Room_ID C110 Description Conference Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 6 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 6 Good
LowNF II
ACMEA
Room_ID C112 Description Electrical Closet (inclusive Of C113)
No ACM Found.
Room_ID C114 Description Telephone Closet
No ACM Found.
Room_ID C121 Description Freight Elevator Lobby/Storage - C115 On Door Change
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
Room_ID C122 Description Lecture Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 4 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 5 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 5 Good
LowNF II
ACMEA
Room_ID CO-A-01 Description A Wing Main E-W Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability DS03 Black duct sealant at seams of foil wrapped fiberglass duct insulation
- Other 275 Good
LowNF II
ACMSF
OT03 Dark gray terrazzo floor with heavy black and white specks
Floor 1947 Good
LowNF II
PACMSF
WC04 Tan, putty like window frame caulking
Frame at wall and ceiling
- Other 160 Good
LowNF II
ACMLF
Room_ID CO-A-01L Description 1st Floor Main Elevator Lobby
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 220 Good
LowNF II
PACMSF
Room_ID CO-B-01A Description B Wing - East (N-S) Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 4720 Good
LowNF II
PACMSF
Room_ID CO-B-01B Description B Wing - West (N-S) Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 4384 Good
LowNF II
PACMSF
Room_ID CO-B-01C Description B Wing - Center (E-W) Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor Floor 455 Good
LowNF II
PACMSF
Room_ID CO-B-01D Description B Wing - South (E-W) Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 1040 Good
LowNF II
PACMSF
Room_ID CO-C-01 Description C Wing - Main E-W Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 1750 Good
LowNF II
PACMSF
Room_ID CO-C-01A Description Lecture Room Corridor
No ACM Found.
Room_ID CO-C-01B Description Short Lecture Hall Corridor
No ACM Found.
Room_ID CO-C-01C Description C Wing - Main N-S Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 3720 Good
LowNF II
PACMSF
Room_ID CO-D-01A Description D Wing - N (E-W) Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 644 Good
LowNF II
PACMSF
Room_ID CO-D-01B Description D Wing - S (e-w) Corridor
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 644 Good
LowNF II
PACMSF
Room_ID CO-E-01 Description E Wing Corridor (includes Vestibule)
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 800 Good
LowNF II
PACMSF
Room_ID D100 Description Conference / AV Services
No ACM Found.
Room_ID D102 Description Women's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall - Ceiling
500 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 132 Good
LowNF II
PACMSF
Room_ID D102A Description Women's Vestibule/lounge
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic
Floor 187 Good
ModerateNF I
ACMSF
Room_ID D104 Description Janitor's Closet
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
Room_ID D105 Description Men's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall - Ceiling
905 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 297 Good
LowNF II
PACMSF
Room_ID D107 Description Red Auditorium
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CDW06 Drywall and associated joint compound associated with
Green and Red Auditorium main and acoustical ceilings Partial acoustical ceiling
- Ceiling 6800 Good
LowF
PACMSF
Room_ID D107-A Description Red Auditorium Front Vestibule
No ACM Found.
Room_ID D107-B Description Auditorium Rear North Vestibule
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 3 Good
LowNF II
PACMEA
Room_ID D107-C Description Auditorium Rear South Vestibule
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 4 Good
LowNF II
PACMEA
Room_ID D108 Description Back of Stage
No ACM Found.
Room_ID D109 Description Backstage Lounge
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
Room_ID D110 Description Backstage Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
176 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 28 Good
LowNF II
PACMSF
Room_ID E100 Description Women's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
352 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 120 Good
LowNF II
PACMSF
Room_ID E101 Description Women's Lounge
No ACM Found.
Room_ID E102 Description Janitor's Closet
No ACM Found.
Room_ID E103 Description Men's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
336 Good
LowNF II
PACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 110 Good
LowNF II
PACMSF
Room_ID E104 Description Conference Room
No ACM Found.
Room_ID E106 Description Reception/Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 484 Good
LowNF II
ACMSF
FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
Room_ID E107 Description Museum
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 900 Good
LowNF II
ACMSF
FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic
Floor 295 Good
ModerateNF I
ACMSF
FTC16 9 inch by 9 inch black floor tile with white streaks and associated mastic Replacement on: Floor
Floor 641 Good
ModerateNF I
PACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 7 Good
LowNF II
ACMEA
Room_ID E108 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 230 Good
LowNF II
ACMSF
FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
Room_ID E109 Description Library Entry/Museum
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability DS03 Black duct sealant at seams of foil wrapped fiberglass duct insulation
- Other 200 Good
LowNF II
ACMSF
FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic
Floor 1128 Good
ModerateNF I
ACMSF
FTC16 9 inch by 9 inch black floor tile with white streaks and associated mastic
Floor 600 Good
ModerateNF I
PACMSF
Room_ID E110 Description Telephone Closet
No ACM Found.
Room_ID E111 Description Electrical Closet
No ACM Found.
Room_ID E112 Description Utility Closet Vestibule
No ACM Found.
Room_ID E113 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 3 Good
LowNF II
PACMEA
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic
Floor 352 Good
ModerateNF I
ACMSF
PS04 Dark brown, tar like sealant, associated with fiberglass pipe runs Limited observation
- Other 4 Good
LowNF II
ACMLF
Room_ID E114 Description Library Stack Area (includes small elevator lobby and east stairwell vestibule)
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability BBA06 Dark brown adhesive associated with 4" black cove base
On columns
- Other 160 Good
LowNF II
ACMLF
DS03 Black duct sealant at seams of foil wrapped fiberglass duct insulation Above ceiling
- Other 4000 Good
LowNF II
ACMSF
FTC02 Miscellaneous 9 inch by 9 inch replacement floor tile and associated mastic Various locations
- Other 100 Good
LowNF I
PACMSF
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic
Floor 12800 Good
ModerateNF I
ACMSF
FTC13 Miscellaneous 12 inch by 12 inch replacement floor tiles (within 9 inch by 9 inch floor tiles) Replacement primarily in center and N side
- Other 900 Good
LowNF I
PACMSF
Room_ID E115 Description Museum Display Room
No ACM Found.
Room_ID E116 Description Janitor's Closet
No ACM Found.
Room_ID E117 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 0 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 2 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID E119 Description Office Suite
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic Under carpet
Floor 1064 Good
LowNF I
ACMSF
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 9 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 9 Good
LowNF II
ACMEA
Room_ID E123 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 2 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID E125 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 5 Good
LowNF II
ACMSF
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID E125-1 Description Printing Room
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic Under carpet
Floor 160 Good
LowNF I
ACMSF
Room_ID E127 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic Underneath carpet
Floor 290 Good
LowNF I
ACMSF
Room_ID E128 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic Underneath carpet
Floor 290 Good
LowNF I
ACMSF
Room_ID EL-1 Description Elevator
No ACM Found.
Room_ID EL-2 Description Elevator
No ACM Found.
Room_ID EL-3 Description Elevator
No ACM Found.
Room_ID EL-4 Description Elevator
No ACM Found.
Room_ID EL-6-1 Description Library Elevator Car
No ACM Found.
Room_ID LO-D-01 Description Auditorium Lobby
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability OT03 Dark gray terrazzo floor with heavy black and white specks Floor 1210 Good
LowNF II
PACMSF
WC04 Tan, putty like window frame caulking - Other 56 Good
LowNF II
ACMLF
Room_ID ST-11-1 Description Stairwell
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
ModerateNF II
PACMEA
Room_ID ST-15-01 Description Stairwell
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
Room_ID ST-15A-DW Description North Projection Booth Stairwell
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA04 Unknown color stair tread mastic - Other 60 Good
ModerateNF II
PACMSF
Room_ID ST-15-DW Description South Projection Booth Stairwell
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA04 Unknown color stair tread mastic - Other 60 Good
ModerateNF II
PACMSF
Room_ID ST-3-1 Description Stairwell
No ACM Found.
Room_ID ST-4-01 Description Stairwell
No ACM Found.
Room_ID ST-5-01 Description Stairwell
No ACM Found.
Room_ID ST-E-1 Description West Stairwell
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic Floor 140 Good
ModerateNF I
ACMSF
Room_ID XE1 Description East Exterior Wall and Main Entry
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK12 Gray, putty like, caulking associated with exterior granite cap seams on retaining walls.
Retaining walls (weathered in areas)
- Other 100 Damaged (Fair)
LowNF II
ACMLF
WC06 Gray, semi-brittle caulking associated with vestibule main entry Observed on north side of entry and south side at top
- Other 30 Good
LowNF II
ACMLF
WC09 Tan, pliable caulk associated with large exterior aluminum window frames Sides and top of window frame units
- Other 350 Good
LowNF II
ACMLF
Room_ID XE2 Description East Exterior Wall - Red Auditorium
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK13 Black, pliable caulking associated with decorative metal grid panel frame above Red Auditorium doors
- Other 40 Good
LowNF II
ACMLF
FD01 Fire doors - Other 4 Good
LowNF II
PACMEA
Room_ID XE3 Description East Exterior Wall - C Wing (short Wall Adjacent To Dock)
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
Room_ID XE4 Description East Exterior Wall - South E Wing
No ACM Found.
Room_ID XE5 Description East Exterior Wall - North E Wing
No ACM Found.
Room_ID XN1 Description North Exterior Wall - Main Red Auditorium
No ACM Found.
Room_ID XN3 Description North Exterior Wall - Main Entry
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK12 Gray, putty like, caulking associated with exterior granite cap seams on retaining walls.
- Other 72 Good
LowNF II
ACMLF
WC09 Tan, pliable caulk associated with large exterior aluminum window frames
- Other 60 Good
LowNF II
ACMLF
Room_ID XN4 Description North Exterior Wall - A Wing
No ACM Found.
Room_ID XN5 Description North Exterior Wall - E Wing
No ACM Found.
Room_ID XS1 Description South Exterior Wall - Red Auditorium
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK12 Gray, putty like, caulking associated with exterior granite cap seams on retaining walls.
Weathered in areas
- Other 70 Damaged (Fair)
LowNF II
ACMLF
Room_ID XS2 Description South Exterior Wall - D Wing Entry
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK12 Gray, putty like, caulking associated with exterior granite cap seams on retaining walls.
Weathered in areas
- Other 24 Damaged (Fair)
LowNF II
ACMLF
WC09 Tan, pliable caulk associated with large exterior aluminum window frames
- Other 140 Good
LowNF II
ACMLF
Room_ID XS3 Description South Exterior Wall - B Wing (dock Entry)
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability FD01 Fire doors - Other 5 Good
LowNF II
PACMEA
WC09 Tan, pliable caulk associated with large exterior aluminum window frames Upper windows
- Other 200 Good
LowNF II
ACMLF
Room_ID XS4 Description South Exterior Wall - C Wing
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability GM01 Miscellaneous gasket materials associated with larger pipe connections
- Other 3 Good
LowNF I
PACMEA
WG04 White, pliable window glazing associated with 1st floor library windows
- Other 75 Good
LowNF II
ACMLF
Room_ID XS5 Description South Exterior Wall - Far West Exterior Of A Wing
No ACM Found.
Room_ID XS6 Description South Exterior Wall - West E Wing
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability GM01 Miscellaneous gasket materials associated with larger pipe connections
- Other 1 Good
LowNF I
PACMEA
Room_ID XW1 Description West Exterior Wall - North Red Auditorium Entry
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK13 Black, pliable caulking associated with decorative metal grid panel frame above Red Auditorium doors Above entry
- Other 24 Good
LowNF II
ACMLF
FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
Room_ID XW2 Description West Exterior Wall - South Red Auditorium Entry
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CK13 Black, pliable caulking associated with decorative metal grid panel frame above Red Auditorium doors
- Other 24 Good
LowNF II
ACMLF
FD01 Fire doors - Other 2 Good
LowNF II
PACMEA
Room_ID XW3 Description West Exterior - C Wing And Long Corridor
No ACM Found.
Room_ID XW4 Description West Exterior Wall - C Wing
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability WG04 White, pliable window glazing associated with 1st floor library windows Continous window set (10 windows)
- Other 240 Good
LowNF II
ACMLF
Level ID 10 Description 10th Level
Room_ID A1000 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 374 Good
ModerateNF II
ACMSF
FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 128 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 8 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 4 Good
LowNF II
ACMEA
Room_ID A1005 Description Office Suite
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 1144 Good
ModerateNF II
ACMSF
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 256 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 16 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 8 Good
LowNF II
ACMEA
Room_ID A1008 Description Telephone Closet
No ACM Found.
Room_ID A1009 Description Office
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 209 Good
LowNF II
ACMSF
FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 2 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A1012 Description Men's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
432 Good
LowNF II
PACMSF
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 3 Good
LowNF II
ACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 170 Good
LowNF II
PACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 4 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 2 Good
LowNF II
ACMEA
Room_ID A1014 Description Women's Restroom
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
- N Wall - E Wall - S Wall - W Wall
528 Good
LowNF II
PACMSF
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 195 Good
LowNF II
ACMSF
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Floor 272 Good
LowNF II
PACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 6 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 3 Good
LowNF II
ACMEA
Room_ID A1015 Description Office Suite
No ACM Found.
SACM ID Material Description Location Quantity Status Condition
Disturbance Potential Hazard
Assessment Friability CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
- Ceiling 418 Good
LowNF II
ACMSF
FD01 Fire doors - Other 1 Good
LowNF II
PACMEA
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
- Other 4 Good
LowNF II
ACMSF
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black) Assume 2 per uni-vent (may only be residual or missing)
- Other 8 Good
LowF
ACMEA
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
- Other 4 Good
LowNF II
ACMEA
Room_ID…