This document contains details for a federal contract solicitation to renovate the second floor of Building 101 at the National Institute of Standards and Technology. The solicitation seeks construction services to convert the existing second floor layout to a less restricted design with open work areas, collaboration spaces, and exposed filing and copy spaces. A site visit is scheduled for January 22, 2024 and questions regarding the solicitation are due by January 29, 2024. Offers for the renovation work must be submitted by February 27, 2024. The magnitude of construction is estimated between $1,000,000 to $5,000,000. Attachments include architectural drawings, specifications, mechanical and fire protection documents outlining the scope of work.
View the file
Other files
Show all 26
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Friability
ASBESTOS INVENTORY SUMMARY
GROUPED BY MATERIAL AND SORTED BY LOCATION
NIST MD - Administration
Asbestos Determination ACM
BBA06 Dark brown adhesive associated with 4" black cove base
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Sporadic locations- N Wall - E Wall - S Wall - W Wall
144 NF IILFA23
144 LFTOTAL QUANTITY
CTA01 Brown adhesive associated with 1 foot by 1 foot light textured pressed board ceiling tile
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Ceiling tiles vary between grid system and directly adhered. Therefore, actual quantity may be lower than estimated
Above LIP- Ceiling 450 NF IISFA200
- Ceiling 418 NF IISFA200-1
Above LIP- Ceiling 264 NF IISFA200-2
- Ceiling 121 NF IISFA201-C
- Ceiling 532 NF IISFA207
- Ceiling 418 NF IISFA209
Observed both glued on and grid- Ceiling 234 NF IISFA28
- Ceiling 187 NF IISFA236
- Ceiling 187 NF IISFA238
- Ceiling 187 NF IISFA239
- Ceiling 187 NF IISFA240
Above LIP- Ceiling 48 NF IISFA241
- Ceiling 209 NF IISFA26
- Ceiling 209 NF IISFA229
- Ceiling 187 NF IISFA230
- Ceiling 209 NF IISFA231
- Ceiling 187 NF IISFA233
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Printed 1/31/2024 11:04:52 AM
- Ceiling 187 NF IISFA234
- Ceiling 187 NF IISFA235
- Ceiling 209 NF IISFA223
- Ceiling 187 NF IISFA224
- Ceiling 304 NF IISFA225
- Ceiling 187 NF IISFA226
- Ceiling 209 NF IISFA227
- Ceiling 187 NF IISFA228
- Ceiling 135 NF IISFA21
- Ceiling 209 NF IISFA215
- Ceiling 209 NF IISFA217
- Ceiling 209 NF IISFA219
- Ceiling 187 NF IISFA221
- Ceiling 187 NF IISFA222
7027 SFTOTAL QUANTITY
FTC01 9 inch by 9 inch light brown floor tile with dark brown and white streaks and associated mastic
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Both tile and mastic reported as ACM
Under carpetFloor 450 NF ISFA200
Under carpetFloor 418 NF ISFA200-1
Under carpetFloor 264 NF ISFA200-2
Under carpetFloor 121 NF ISFA201-C
Under carpetFloor 532 NF ISFA207
Under carpetFloor 418 NF ISFA209
Floor 48 NF ISFA241
Assumed under carpetFloor 209 NF ISFA26
Under carpetFloor 187 NF ISFA234
Under carpetFloor 187 NF ISFA235
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Printed 1/31/2024 11:04:53 AM
Under carpetFloor 187 NF ISFA236
Under carpetFloor 0 NF ISFA238
Under carpetFloor 187 NF ISFA239
Under carpetFloor 187 NF ISFA240
Under carpetFloor 209 NF ISFA223
Under carpetFloor 187 NF ISFA224
Under carpetFloor 187 NF ISFA226
Under carpetFloor 187 NF ISFA228
Under carpetFloor 187 NF ISFA230
Under carpetFloor 187 NF ISFA233
Under carpetFloor 135 NF ISFA21
Under carpetFloor 209 NF ISFA215
Under carpetFloor 209 NF ISFA217
Under carpetFloor 209 NF ISFA219
Under carpetFloor 187 NF ISFA221
Under carpetFloor 187 NF ISFA222
5675 SFTOTAL QUANTITY
FTC03 9 inch by 9 inch white floor tile with dark gray streaks and associated mastic
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Tile reported as ACM. No mastic reported with sample
Underneath carpetFloor 121 NF ISFA201-C
121 SFTOTAL QUANTITY
MA02 Black mastic like (painted tan) soundproofing associated with uni-vent chase walls and uni-vents
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Photo shows back of metal chase wall disassembled
- Other 4 NF IISFA200-1
- Other 4 NF IISFA200-2
- Other 130 NF IISFA201-C
- Other 5 NF IISFA207
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 4 NF IISFA209
- Other 2 NF IISFA215
- Other 2 NF IISFA239
- Other 2 NF IISFA240
- Other 130 NF IISFA212
- Other 195 NF IISFA214
- Other 2 NF IISFA231
- Other 2 NF IISFA233
- Other 2 NF IISFA234
- Other 2 NF IISFA235
- Other 2 NF IISFA236
- Other 2 NF IISFA238
- Other 3 NF IISFA225
- Other 2 NF IISFA226
- Other 2 NF IISFA227
- Other 2 NF IISFA228
- Other 2 NF IISFA229
- Other 2 NF IISFA230
- Other 2 NF IISFA217
- Other 2 NF IISFA219
- Other 2 NF IISFA221
- Other 2 NF IISFA222
- Other 2 NF IISFA223
- Other 2 NF IISFA224
515 SFTOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
PF02 White mudded pipe joint at end of rubber insulated uni-vent pipes (painted black)
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Assumed in all uni-vents. Observed missing or damaged fittings in multiple areas
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA212
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA222
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA238
Assume 2 per uni-vent (may only be residual or missing)
- Other 8 FEAA200-1
Assume 2 per uni-vent (may only be residual or missing)
- Other 8 FEAA200-2
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA201-C
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA235
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA236
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA239
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA240
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA228
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA229
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA230
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA231
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA233
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA234
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA221
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA223
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA224
Assume 2 per uni-vent (may only be residual or missing)
- Other 6 FEAA225
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA226
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA227
Assume 2 per uni-vent (may only be residual or missing)
- Other 10 FEAA207
Assume 2 per uni-vent (may only be residual or missing)
- Other 8 FEAA209
Assume 2 per uni-vent (may only be residual or missing)
- Other 6 FEAA214
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA215
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA217
Assume 2 per uni-vent (may only be residual or missing)
- Other 4 FEAA219
134 EATOTAL QUANTITY
PS01 Black tar sealant associated with fiberglass insulated flex ducts inside uni-vent
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Other 4 NF IIEAA200-1
- Other 4 NF IIEAA200-2
- Other 2 NF IIEAA201-C
- Other 4 NF IIEAA209
- Other 2 NF IIEAA212
- Other 3 NF IIEAA214
- Other 2 NF IIEAA238
- Other 2 NF IIEAA239
- Other 2 NF IIEAA240
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 5 NF IIEAA207
- Other 2 NF IIEAA230
- Other 2 NF IIEAA231
- Other 2 NF IIEAA233
- Other 2 NF IIEAA234
- Other 2 NF IIEAA235
- Other 2 NF IIEAA236
- Other 2 NF IIEAA224
- Other 3 NF IIEAA225
- Other 2 NF IIEAA226
- Other 2 NF IIEAA227
- Other 2 NF IIEAA228
- Other 2 NF IIEAA229
- Other 2 NF IIEAA215
- Other 2 NF IIEAA217
- Other 2 NF IIEAA219
- Other 2 NF IIEAA221
- Other 2 NF IIEAA222
- Other 2 NF IIEAA223
67 EATOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Asbestos Determination ND
BBA07 Cream latex adhesive associated with 4" black cove base
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- E Wall - W Wall 36 NF IILFA24
- E Wall - S Wall 26 NF IILFA24-1
- N Wall - E Wall - W Wall 31 NF IILFA24-2
93 LFTOTAL QUANTITY
BBA10 Tan adhesive associated with 4" black cove base
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Other 2 NF IILFA200
2 LFTOTAL QUANTITY
BBA17 Tan, pliable adhesive associated with dark brown 4" cove base
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Observed in two rooms
- N Wall - E Wall - S Wall - W Wall
54 NF IILFA25
- N Wall - E Wall - S Wall - W Wall
54 NF IILFA27
108 LFTOTAL QUANTITY
CDW07 Off-white drywall on and associated joint compound
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Drywall with plastic cap at top - Associated with A24 and A41 suites
- E Wall - W Wall 288 FSFA24
- E Wall - S Wall 260 FSFA24-1
- N Wall - E Wall 210 FSFA24-2
758 SFTOTAL QUANTITY
CDW13 Gray, fibrous drywall and associated joint compound
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Associated with A200 build-out in approximately 2014
Walls for A200-1 and A200-2- N Wall - S Wall 480 FSFA200
- N Wall 198 FSFA200-1
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- S Wall 176 FSFA200-2
854 SFTOTAL QUANTITY
CK03 White silicone caulk associated with toilet and urinal wall seams
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Other 16 NF IILFA212
- Other 12 NF IILFA214
- Other 18 NF IILFA25-1
- Other 18 NF IILFA27-1
64 LFTOTAL QUANTITY
DS01 White duct sealant associated with foil wrapped fiberglass insulation seams
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Other 12 NF IISFA25
- Other 80 NF IISFA27
92 SFTOTAL QUANTITY
DS02 Dark red pliable sealant associated with older ribbed ducting
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Based on field observations, assumed inside all uni-vents
- Other 4 NF IIEAA200-1
- Other 4 NF IIEAA200-2
- Other 2 NF IIEAA223
- Other 2 NF IIEAA224
- Other 3 NF IIEAA225
- Other 2 NF IIEAA226
- Other 3 NF IIEAA214
- Other 2 NF IIEAA215
- Other 2 NF IIEAA217
- Other 2 NF IIEAA219
- Other 2 NF IIEAA221
- Other 2 NF IIEAA222
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 3 NF IIEAA24-1
- Other 3 NF IIEAA24-2
- Other 2 NF IIEAA201-C
- Other 5 NF IIEAA207
- Other 4 NF IIEAA209
- Other 2 NF IIEAA212
- Other 2 NF IIEAA234
- Other 2 NF IIEAA235
- Other 2 NF IIEAA236
- Other 2 NF IIEAA238
- Other 2 NF IIEAA239
- Other 2 NF IIEAA240
- Other 2 NF IIEAA227
- Other 2 NF IIEAA228
- Other 2 NF IIEAA229
- Other 2 NF IIEAA230
- Other 2 NF IIEAA231
- Other 2 NF IIEAA233
73 EATOTAL QUANTITY
DS05 Brown pliable duct sealant associated with uni-vent ducting
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Based on field observations, assumed inside all uni-vents
- Other 2 NF IIEAA224
- Other 2 NF IIEAA226
- Other 2 NF IIEAA228
- Other 2 NF IIEAA230
- Other 2 NF IIEAA233
- Other 2 NF IIEAA234
- Other 2 NF IIEAA201-C
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 2 NF IIEAA212
- Other 3 NF IIEAA214
- Other 2 NF IIEAA222
- Other 2 NF IIEAA221
- Other 2 NF IIEAA223
- Other 3 NF IIEAA225
- Other 2 NF IIEAA227
- Other 2 NF IIEAA229
- Other 2 NF IIEAA231
- Other 4 NF IIEAA200-2
- Other 5 NF IIEAA207
- Other 4 NF IIEAA209
- Other 2 NF IIEAA215
- Other 2 NF IIEAA217
- Other 2 NF IIEAA219
- Other 2 NF IIEAA235
- Other 2 NF IIEAA236
- Other 2 NF IIEAA238
- Other 2 NF IIEAA239
- Other 2 NF IIEAA240
- Other 4 NF IIEAA200-1
67 EATOTAL QUANTITY
DS08 Green, pliable duct sealant
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Observed from wet wall- Other 10 NF IISFA27-1
10 SFTOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
FSM01 Red firestop material associated with wall penetrations
Location Quantity FriabilityRoom ID Comments
- Other 1 NF IIEAA208
- Other 5 NF IIEAA218
- Other 1 NF IIEAA232
7 EATOTAL QUANTITY
FSM05 Gray, putty like, fire stop material in exterior abandoned wall penetration
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Other 5 NF IIEAA23
5 EATOTAL QUANTITY
LIP06 2 foot by 2 foot lay-in ceiling panel with shallow heavy fissures and pinholes (1' by 1' faux pattern)
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Ceiling 48 FSFA241
48 SFTOTAL QUANTITY
LIP09 2' by 4' lay-in ceiling panel with small and medium fissures and random pinholes
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Ceiling 144 FSFA24-1
- Ceiling 170 FSFA25
- Ceiling 170 FSFA27
484 SFTOTAL QUANTITY
LIP13 2' by 4' white lay-in ceiling panel with sand texture and shallow pinholes
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Ceiling 396 FSFA24
- Ceiling 110 FSFA24-2
506 SFTOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
LIP17 2' by 2' lay-in ceiling panels with random small fissures and pinholes
Location Quantity FriabilityRoom ID Comments
Similar to LIP10 but appears newer
- Ceiling 450 FSFA200
- Ceiling 264 FSFA200-2
714 SFTOTAL QUANTITY
MA16 Brown brittle adhesive used for tar paper (TP01) behind heating units
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Limited observation and access behind heating units
- Other 128 NF IISFA200-1
- Other 70 NF IISFA222
- Other 70 NF IISFA223
- Other 70 NF IISFA224
- Other 105 NF IISFA225
- Other 70 NF IISFA226
- Other 70 NF IISFA215
- Other 70 NF IISFA217
- Other 70 NF IISFA219
- Other 70 NF IISFA221
- Other 140 NF IISFA200-2
- Other 70 NF IISFA201-C
- Other 175 NF IISFA207
- Other 140 NF IISFA209
- Other 70 NF IISFA212
- Other 105 NF IISFA214
- Other 70 NF IISFA234
- Other 70 NF IISFA235
- Other 70 NF IISFA236
- Other 70 NF IISFA238
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 70 NF IISFA239
- Other 70 NF IISFA240
- Other 70 NF IISFA227
- Other 70 NF IISFA228
- Other 70 NF IISFA229
- Other 70 NF IISFA230
- Other 70 NF IISFA231
- Other 70 NF IISFA233
2333 SFTOTAL QUANTITY
OT02 Grout associated with tan ceramic 4" by 10" wall block
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- N Wall - E Wall - S Wall - W Wall
208 NF IISFA216
208 SFTOTAL QUANTITY
OT04 White grout associated with 3' x 4' granite wall panel seams
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- S Wall 80 NF IISFA200
80 SFTOTAL QUANTITY
OT07 Mortar associated with 4" by 4" red clay floor tile
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Floor 42 NF IISFA216
42 SFTOTAL QUANTITY
PF01 Light gray mudded pipe fittings
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Based on NIST policy all fittings presumed ACM. Mud may only be present at edges of fittings (see photo)
Assume 2 per uni-vent chase- Other 8 FEAA200-1
Assume 2 per uni-vent chase- Other 8 FEAA200-2
Assume 2 per uni-vent chase- Other 4 FEAA201-C
Assume 2 per uni-vent chase- Other 10 FEAA207
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Assume 2 per uni-vent chase- Other 8 FEAA209
Assume 2 per uni-vent chase- Other 4 FEAA212
Assume 2 per uni-vent chase- Other 4 FEAA235
Assume 2 per uni-vent chase- Other 4 FEAA236
Assume 2 per uni-vent chase- Other 4 FEAA238
Assume 2 per uni-vent chase- Other 4 FEAA239
Assume 2 per uni-vent chase- Other 4 FEAA240
- Other 1 FEAA28-1
Assume 2 per uni-vent chase- Other 4 FEAA228
Assume 2 per uni-vent chase- Other 4 FEAA229
Assume 2 per uni-vent chase- Other 4 FEAA230
Assume 2 per uni-vent chase- Other 4 FEAA231
Assume 2 per uni-vent chase- Other 4 FEAA233
Assume 2 per uni-vent chase- Other 4 FEAA234
Assume 2 per uni-vent chase- Other 4 FEAA222
Assume 2 per uni-vent chase- Other 4 FEAA223
Assume 2 per uni-vent chase- Other 4 FEAA224
Assume 2 per uni-vent chase- Other 6 FEAA225
Assume 2 per uni-vent chase- Other 4 FEAA226
Assume 2 per uni-vent chase- Other 4 FEAA227
Assume 2 per uni-vent chase- Other 6 FEAA214
Assume 2 per uni-vent chase- Other 4 FEAA215
Behind access hatch, open ceiling- Other 12 FEAA216
Assume 2 per uni-vent chase- Other 4 FEAA217
Assume 2 per uni-vent chase- Other 4 FEAA219
Assume 2 per uni-vent chase- Other 4 FEAA221
147 EATOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
PL01 Tan plaster with white skim coat
Location Quantity FriabilityRoom ID Comments
- N Wall - E Wall - S Wall - W Wall
480 NF IISFA21
- Ceiling 170 NF IISFA212
- Ceiling 272 NF IISFA214
- Ceiling 42 NF IISFA216
- N Wall - S Wall - W Wall 496 NF IISFA24
- N Wall 180 NF IISFA24-1
- N Wall - E Wall - S Wall - W Wall - Ceiling
384 NF IISFA28-1
- N Wall 110 NF IISFA24-2
- N Wall 80 NF IISFA25
- Ceiling 272 NF IISFA25-1
Assumed on east wall- N Wall - E Wall - S Wall 410 NF IISFA26
- Ceiling 323 NF IISFA27-1
- N Wall - S Wall - W Wall 440 NF IISFA28
3659 SFTOTAL QUANTITY
TP01 Tar paper fiberglass panels associated with exterior walls inside uni-vents
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
- Other 22 NF IISFA229
- Other 44 NF IISFA200-1
- Other 44 NF IISFA200-2
- Other 22 NF IISFA201-C
- Other 54 NF IISFA207
- Other 44 NF IISFA209
- Other 22 NF IISFA236
- Other 22 NF IISFA238
- Other 22 NF IISFA239
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 22 NF IISFA240
- Other 22 NF IISFA228
- Other 22 NF IISFA230
- Other 22 NF IISFA231
- Other 22 NF IISFA233
- Other 22 NF IISFA234
- Other 22 NF IISFA235
- Other 22 NF IISFA222
- Other 22 NF IISFA223
- Other 22 NF IISFA224
- Other 36 NF IISFA225
- Other 22 NF IISFA226
- Other 22 NF IISFA227
- Other 20 NF IISFA212
- Other 32 NF IISFA214
- Other 22 NF IISFA215
- Other 22 NF IISFA217
- Other 22 NF IISFA219
- Other 22 NF IISFA221
736 SFTOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Asbestos Determination PACM
EI01 Electrical insulators (cement board, phenolic panels, etc.)
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Assumed inside electrical switch cabinets
9 cabinents- Other 9 NF IIEAA23
9 EATOTAL QUANTITY
FD01 Fire doors
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Doors with potential fire rating insulation inside the doors
- Other 1 NF IIEAA200-1
- Other 1 NF IIEAA200-2
- Other 1 NF IIEAA201-C
- Other 1 NF IIEAA207
- Other 1 NF IIEAA209
- Other 1 NF IIEAA21
- Other 1 NF IIEAA236
- Other 1 NF IIEAA238
- Other 1 NF IIEAA239
- Other 1 NF IIEAA240
- Other 1 NF IIEAA27
- Other 4 NF IIEAA23
- Other 1 NF IIEAA230
- Other 2 NF IIEAA231
- Other 1 NF IIEAA233
- Other 1 NF IIEAA234
- Other 1 NF IIEAA235
- Other 1 NF IIEAA224
- Other 2 NF IIEAA225
- Other 1 NF IIEAA226
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
- Other 2 NF IIEAA227
- Other 1 NF IIEAA228
- Other 2 NF IIEAA229
- Other 1 NF IIEAA215
- Other 1 NF IIEAA217
- Other 1 NF IIEAA219
- Other 1 NF IIEAA221
- Other 1 NF IIEAA222
- Other 1 NF IIEAA223
36 EATOTAL QUANTITY
MA01 Adhesive and grout associated with restroom 4x4 ceramic wall tiles
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Not sampled due to aesthetics
- N Wall - E Wall - S Wall - W Wall
432 NF IISFA212
- N Wall - E Wall - S Wall - W Wall
528 NF IISFA214
- N Wall - E Wall - S Wall - W Wall
528 NF IISFA25-1
- N Wall - E Wall - S Wall - W Wall
576 NF IISFA27-1
2064 SFTOTAL QUANTITY
MA18 Adhesive associated with 2' by 2' no slip tan rubber flooring
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Observed in two rooms - Not sampled due to aesthetic reasons
Floor 170 NF IISFA25
Floor 170 NF IISFA27
340 SFTOTAL QUANTITY
OT01 Grout and thin set associated with restroom 1' by 1' ceramic tile floor
Material DescriptionSACM ID
Location Quantity FriabilityRoom ID Comments
Not sampled due to aesthetic reasons
Floor 170 NF IISFA212
Floor 272 NF IISFA214
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each
Floor 272 NF IISFA25-1
Floor 323 NF IISFA27-1
1037 SFTOTAL QUANTITY
Legend: F=Friable, NF I = Category I Non-Friable, NFII = Category II Non-Friable. N=North, E=East, W=West, S=South, SF=Square Feet, LF=Linear Feet, EA=Each