Attachment 14 - V-SURV-SUAS-SHEET 1.pdf
PDF 1 MB Posted
- Solicitation number
- IFB-36C77626B0025
About this file
This is a Topographic Survey document prepared by Colliers Engineering & Design for the VA Medical Center in Fishkill, Wappingers Falls, Dutchess County, New York. The survey was conducted as part of the SPEES Design Build project and completed on February 2, 2024, under project number 23010570A. The document is marked as preliminary and includes topographic mapping with contour lines, utility locations, building footprints, and site features across the medical center property.
The survey was performed through field work conducted by Colliers Engineering and Design on November 8-10, 13-16, and 20-21, 2023, with topographic survey work performed by Cooper Aerial on December 13, 2023. The horizontal control was established using the NYSNET VRS system with NAD83 datum relative to the New York State Plane Coordinate System East Zone, while vertical positioning was based on the NYSNET RTK GPS network with NAVD 1988 datum. Underground utilities shown are based on visible evidence and record drawings but are subject to field verification by excavation. The document includes standard survey notes indicating that easements and subsurface structures are not guaranteed unless physically evident, and the survey is subject to all recorded rights, easements, covenants, and restrictions.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H
Y D
H
Y D
H
Y D
50 50 100
SCALE : 1" = 50'
Linear unit of measure: US Survey Foot (1 ft = 1200/3937 m)
TOPOGRAPHIC SURVEY
FIELD BOOK:PAGE:
XXXX
N
S
E W
N O
R T
H
N A
D 83 C
O O
R D
IN
A
TES
LEGEND
ABBREVIATIONS
H
Y D
UNAUTHORIZED ALTERATION OR ADDITION TO A SURVEY OR ENGINEERING MAP BEARING A LICENSED LAND SURVEYOR OR PROFESSIONAL ENGINEER IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2, OF THE NEW YORK STATE EDUCATION LAW.
ONLY MAPS WITH THE LAND SURVEYOR OR PROFESSIONAL ENGINEER'S SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE LAND SURVEYOR OR PROFESSIONAL ENGINEER’S ORIGINAL WORK AND OPINION.
R E
V D
A T
E D
R A
W N
B
D
E S
C R
I P
T I O
N
SHEET NUMBER:
SCALE:
PROJECT NUMBER:
DRAWN BY:
DATE:
DRAWING NAME:
CHECKED BY:
SHEET TITLE:
PROTECT YOURSELF
Copyright © 2024. Colliers Engineering & Design All Rights Reserved. This drawing and all the information contained herein is authorized for use only by the party for whom the services were contracted or to whom it is certified. This drawing may not be copied, reused, disclosed, distributed or relied upon for any other purpose without the express written consent of Colliers Engineering & Design.
ALL STATES REQUIRE NOTIFICATION OF
EXCAVATORS, DESIGNERS, OR ANY PERSON
PREPARING TO DISTURB THE EARTH'S
SURFACE ANYWHERE IN ANY STATE
FOR STATE SPECIFIC DIRECT PHONE NUMBERS
VISIT: WWW.CALL811.COM
V-SURV-SUAS
A
V
S
U R
V S
U A
S d w g
S
H E
E T y
J D
I M
U R
A
R
REVIEWED BY:
NOTE: DO NOT SCALE DRAWINGS FOR CONSTRUCTION.
CITY OF PITTSBURGHDEPARTMENT OF CITY PLANNINGAPPROVED: _______________________ CITY PLANNING COMMISSION
_______________________ CHAIRMANATTEST: _______________________ _______________________SECRETARY
Phone:
Engineering
& Design www.colliersengineering.com
C O N S U L T I N G
Engineering
& Design
ENGINEERS + SURVEYING
R E
V D
A T
E D
R A
W N
D
E S
C R
I P
T I O
N
TOPOGRAPHIC SURVEY
SPEES DESIGN BUILD
WAPPINGERS FALLS
VA MEDICAL CENTER
FISHKILL
DUTCHESS COUNTY
STATE OF NEW YORK
AS SHOWN 2/2/24 JWD LJB
23010570A of
FOR
PTH
ALBANY
18 Corporate Woods Blvd.
Suite 400
Albany, NY 12211
518.459.3252
COLLIERS ENGINEERING & DESIGN CT, P.C.
DOING BUSINESS AS MASER CONSULTING
ENGINEERING & LAND SURVEYING
Doing Business as
UNAUTHORIZED ALTERATION OR ADDITION TO A
SURVEY MAP BEARING A LICENSED LAND SURVEYOR'S
SEAL IS A VIOLATION OF SECTION 7209, SUB-DIVISION 2,
OF THE NEW YORK STATE EDUCATION LAW.
ONLY BOUNDARY SURVEY MAPS WITH THE SURVEYOR'S
SEAL ARE GENUINE TRUE AND CORRECT COPIES OF THE
SURVEYOR'S ORIGINAL WORK AND OPINION.
GENERAL NOTES:
1. UNDERGROUND UTILITIES SHOWN HEREON BASED ON UTILITY EVIDENCE VISIBLE AT GROUND SURFACE
AND RECORD DRAWINGS AND ARE SUBJECT TO FIELD VERIFICATION BY EXCAVATION. UTILITIES SHOWN DO
NOT PURPORT TO CONSTITUTE OR REPRESENT ALL UTILITIES LOCATED UPON OR ADJACENT TO THE
SURVEYED PREMISES.
2. THE OFFSETS OR DIMENSIONS SHOWN HEREON, FROM THE PROPERTY LINES TO THE STRUCTURES, ARE
FOR A SPECIFIC PURPOSE AND USE; THEREFORE, THEY ARE NOT INTENDED TO MONUMENT THE PROPERTY
LINES OR TO GUIDE THE ERECTION OF FENCES, ADDITIONAL STRUCTURES OR ANY OTHER IMPROVEMENTS.
3. EASEMENTS AND/OR SUBSURFACE STRUCTURES RECORDED OR UNRECORDED ARE NOT GUARANTEED
UNLESS PHYSICALLY EVIDENT ON THE PREMISES AT THE TIME OF THE SURVEY.
4. SUBJECT TO ALL RIGHTS, EASEMENTS, COVENANTS AND RESTRICTIONS OF RECORD.
5. SUBJECT TO ANY STATE OF FACTS AN UP-TO-DATE ABSTRACT OF TITLE WOULD DISCLOSE.
6. BASIS OF BEARING IS NEW YORK STATE PLANE COORDINATE SYSTEM EAST ZONE. CONTROL WAS
ESTABLISHED USING NYSNET VRS SYSTEM. THE HORIZONTAL DATUM IS RELATIVE TO NAD83
7. THE VERTICAL POSITION OF THE HEREIN SURVEY IS BASED ON THE NYSNET RTK GPS NETWORK AND IS
SUBJECT TO FURTHER ADJUSTMENT TO ANY LOCAL NGS BENCHMARKS. THE VERTICAL DATUM IS RELATIVE
8. TO NAVD 1988.
9. LINE WORK SHOWN HERE ON IS BASED UPON A FIELD SURVEY CONDUCTED BY COLLIERS ENGINEERING
AND DESIGN ON NOVEMBER 8-10, 13-16 AND 20-21 2023.
10. TOPOGRAPHIC SURVEY PERFORMED BY COOPER AERIAL AND FURTHER REFERENCED FROM CAD FILE
ENTITLED "WAPPINGERS FALLS" ON DECEMBER 13, 2023.
P
R
E
L
I M
I N
A
R
| Sheets and Views |
| SHEET 1 |
File details come from the government source that posted it. Updated .