Attachment 13 - DWGS Combined 5 of 5 620A4 22 700.pdf
PDF 42 MB Posted
- Solicitation number
- IFB-36C77626B0025
About this file
These are telecommunications infrastructure upgrade design drawings for the EHRM Infrastructure Upgrades project at Hudson Valley Medical Center in Wappingers Falls, New York. The drawings depict Level 0-3 telecommunications plans across multiple buildings (016, 017, 018, 019, 020, 021, and 035), detailing wireless access point (WAP) locations, data outlet placements, cable tray routing, telecommunications rooms (TR), and associated infrastructure modifications. The work encompasses removal and replacement of existing Category 6 cabling with Category 6A (CAT6A) ports and cables throughout the facility, with all cabling routed through existing pathways where feasible while maintaining 40% conduit fill ratios. Key technical specifications include CAT6A cables with outer diameter not exceeding 0.250 inches, J-hook support spacing of 48-60 inches apart, pull boxes sized per ANSI/TIA-569 at 100-foot intervals, and proper fire-stopping and sealing at wall and ceiling penetrations. General notes specify that contractors must field-verify all existing equipment, protect existing work from damage, segregate data cabling from security and fire alarm systems using separate raceways or tray dividers, and provide full installation, termination, testing, labeling, and certification of fully functional outlets.
The project is a Service-Disabled Veteran-Owned Small Business (SDVOSB) set-aside competitive solicitation (IFB-36C77626B0025) administered by the Department of Veterans Affairs Technology Acquisition Center Austin. The drawings are 100% construction documents dated November 7, 2025, prepared by SPEES Design Build with architectural/engineering support from the firm located in Kent, Washington. Multiple telecommunications rooms are designated throughout each building level to serve specific areas, with detailed outlet schedules indicating port quantities and outlet types (labeled as DD1-DD6 and N2-N4 designations) distributed across clinical, administrative, mechanical, and support spaces. The contractor is responsible for coordinating with the VA for exact outlet placement, evaluating existing cable tray and sleeves for potential reuse, and providing fire-stop materials and vertical sleeve penetrations as required for backbone cabling distribution between levels.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
WAP WAP WAP WAP
WAP
WAP
1A
1A
1A
STERILIZER
ROOM
OPERATING
ROOM
AUTOCLAVE
ROOM
315A SCRUB ROOM
CORRIDOR 03
CORRIDOR 02
OPERATING
ROOM 1
STERILE SUPPLY
STORAGE
STAIR HALL 01
HOUSEKEEPING
CLOSET
RECOVERY
ROOM
ROOF ACCESS
O.R. SUPPLIES
MEN'S LOCKER
ROOM
303A
TOILET
303B
SHOWER
303C
CORRIDOR 01
SUPPLIES
FEMALE
LOCKERS
306A
SHOWER
306C
FEMALE
LOCKERS
DIRTY PUMPS
STORAGE
OFFICE
302B
WORK SHOP
RECOVERY
ROOM
301A
MENS LOCKER
ELEVATOR
TOILET
306B
A
B C D E F G H
TYP.
STAFF LOUNGE
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE SERVED
FROM TELECOMMUNICATIONS ROOM G-203 ON LEVEL 02.
2 2 2
BLDG 017
BLDG 016: SEE SHEET 016ET103
N2
DD3 DD3
DD2
DD4
DD3
N2
N2
N2
N2
N2
DD1
AREA SHOWN
BLDG 017
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/7 /2
:0
:2
P
M
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
017ET103
BLDG 017 - LEVEL 03 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
- 1/4" = 1'-0"
1 BLDG 017 - LEVEL 03 - TELECOMMUNICATIONS PLAN 2'0 4' 8'
PROJECT
NORTH
TRUE
NORTH
Revisions: Date:
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250" (6.35mm) (4) CAT6A CABLES WITH AN 0.250" (6.35mm) OD OR SMALLER CAN
BE INSTALLED IN A 3/4” CONDUIT SUPPORTING A 40% FILL RATIO.
14. ALL COPPER AND FIBER OPTIC CABLES SHALL BE SUPPORTED BY J HOOKS SPACED
48" TO 60" APART. J HOOKS SHALL NOT EXCEED 40% FILL RATIO.
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE DETAIL '1' ON SHEET ET501
AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FED WITH (2) CAT6A CABLES.
CAT6A FEEDING LEVEL 03 TO BE ROUTED THROUGH VERTICAL FIRE STOP SLEEVE
PENETRATION BACK TO TR INDICATED ON "TELECOMMUNICATIONS WAO AND CABLE
TRAY SCHEDULE" ON SHEET ET701.
WAP
WAP
WAP
WAP
WAP
WAP
WAP
AREA SHOWN
BLDG 018
A B C D E F G H I J K L M N
DATA OUTLETS AND CABLES ON FLOOR 00, BLDG 018 ARE
NOT TO BE RE-CABLED IN THE SCOPE OF THIS PROJECT.
LOCKER ROOM
CENTER STAIR HALL
VESTIBULE 01
VESTIBULE 02
008A
STAIR HALL 3
001G
ELEVATOR
D.214C
ULTRASOUND 3
001A
BONE DENSITOMERY
001B
TOUCHDOWN SPACE
001C
CLEAN UTILITY
001D
ULTRASOUND 2
001E
TOILET
001E.1
TOILET
001F.1
ULTRASOUND 1
001F
MECHANICAL ROOM
TOILET ROOM
STORAGE
001N.1
OFFICE A
001N.1 OFFICE B
001J
OFFICE C
001I
ELECTRICAL ROOM
001H
TOILET
RADIOLOGY
001M
SOILED UTILITY
001L
TOILET
001K.1
STAFF TOILET
001N.1
R/F ROOM
001K.1
EQUIPMENT STORAGE
001N.3
STORAGE
001H.1
EMERGENCY POWER
ELECTRICAL ROOM
WORK AREA
001N
RECEPTION
001N.5
SCOPE DECON
DECONTAMINATION
CART AUTO. WASH
SCOPE PROCESS
ANTE ROOM 03
ANTE ROOM 04
H.A.C.
FEMALE LOCKER
FEMALE BATH
MALE LOCKER
16 MALE BATH
CLEAN PREPARATION
STERILIZERS
STERILE / NON-STERILE
ANTE ROOM 02
CLEAN STORAGE
FEMALE LOCKER
ANTE ROOM 01
TR
FEMALE TOILET
MALE TOILET
MALE BATH.
H.A.C.
TECH. OFFICE
CHIEF OFFICE
ELECTRICAL
DISTRIBUTION
CORRIDOR 1
CORRIDOR 2
ENTRY
018ET400
018ET400
018ET400
018ET400
BLDG 111: SEE SHEET 111ET100
BLDG 017: SEE SHEET 17ET100
BLDG 018
BLDG 018
BLDG 016: SEE SHEET 16ET100
BLDG 018
N4
N4
N4 N4
N4
N4 N4
N4
N4
N4
N4
N4
N4 N4 N4
N4
N4
N4
N4
N4
DD3
DD4
DD4
DD4
DD3
DD4
DD4
DD2
DD1
DD1
DD4
DD4
DD4
DD1
DD4
DD4DD4DD4
DD4
DD4
N2
N2 N2
N2
N2
DD4 DD4
DD4
DD4
N2
DD1
DD4
DD1
N2
N4
N4
DD1
N4
N4
N4
N4
N4 N4
N4 N4
N4
N4
N4
N4
N4
N4
N4N4
N4
N2
N2
N4
N4
N4
N2
N2
N2
N2
N2
N2
N2
N2
N4
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1 DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
DD1
N4
DD1
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1 /2
:5
:4 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
018ET100
BLDG 018 - LEVEL 00 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
TRUE
NORTH
4'0 8' 16'
PROJECT
NORTH
- 1/8" = 1'-0"
1 BLDG 018 - LEVEL 00 - TELECOMMUNICATIONS PLAN
Revisions: Date:
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250" (6.35mm) (4) CAT6A CABLES WITH AN 0.250" (6.35mm) OD OR SMALLER CAN
BE INSTALLED IN A 3/4” CONDUIT SUPPORTING A 40% FILL RATIO.
6" X 4" EXISTING CABLE TRAY.
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAP
180°
180°
180°
180°
180°
180°
AREA SHOWN
BLDG 018
A B C D E F G H I J K L M N
EXAM ROOM
EXAM ROOM
SOCIAL WORKER OFFICE
NUTRITION CLINIC
SUPPLY CLOSET
OFFICE
ANTE CORRIDOR
TOILET
EXAM ROOM
OFFICE
OFFICE
EXAM ROOM
EXAM ROOM
144 EXAM ROOM
EXAM ROOM
OFFICE
OFFICE
ANTE CORRIDOR
OFFICE
OFFICE
OFFICE
OFFICE
TOILET
144A
BATHROOM
148A
TOILET
STAIR HALL
OFFICE
EXAM ROOM
SOCIAL WORKER OFFICE
OFFICE
123 SF
PROVIDER
EXAM ROOM
STORAGE ROOM
119 STOCK ROOM
PROVIDER
TOILET
PATIENT EDUCATION
TELEPHONE CLOSET
47 SF
SPRINKLER CLOSET
TOILET
E.M.S. CLOSET
OFFICE
OFFICE
OFFICE
TOILET
EXAM ROOM
105 EXAM ROOM
STAFF LOUNGE
OFFICE
OFFICE
OFFICE
ANTE CORRIDOR
STAIR HALL
CONFERENCE ROOM
ELEVATOR
WAITING AREA
CORRIDOR 06
ANTE CORRIDOR
ANTE CORRIDOR
ANTE CORRIDOR
CORRIDOR 05
ANTE CORRIDOR
CORRIDOR
ANTE CORRIDOR
CORRIDOR 03
CHECK-IN
ELEC. CL.
115A
RECEPTION 02
RECEPTION 02
CORRIDOR
WAITING AREA
018ET401a
018ET401a
TYP.
WAITING ROOM
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE
SERVED FROM TELECOMMUNICATIONS ROOM 115A.
TR
115A
2 2
018ET401a
018ET401a
018ET401b
018ET401b
BLDG 111: SEE SHEET 111ET101
BLDG 017: SEE SHEET 17ET101
BLDG 018
BLDG 018
BLDG 016: SEE SHEET 016ET101
BLDG 018
TYP.
N2
N2
N2
N2
N2 N2
N2 N2
N2
N2 N2 N2
N2
N2
N2
N2
N2
N2 N2
N2
N2
N2 N2 N2
N2 N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2 N2
N2
N2
N2
N2
N2
N2
N2
N2 N2
N2
DD4
DD4
DD3
DD3 DD3 DD3
DD3
DD2
DD2
DD6
DD4
DD4
DD3
DD4
DD3
DD3 DD3 DD3
DD4
DD4
DD3
DD4 DD3
DD3
DD3
DD4
DD2
DD4
DD3
DD3
DD3
DD3
DD3DD3
DD4
DD3
DD4
DD3
DD3
DD2
DD3
DD3
DD4
DD3
DD3
DD3
DD3DD3
DD3
DD1
DD3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1 /2
:5
:5 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
018ET101
BLDG 018 - LEVEL 01 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
TRUE
NORTH
4'0 8' 16'
PROJECT
NORTH
- 1/8" = 1'-0"
1 BLDG 018 - LEVEL 01 - TELECOMMUNICATIONS PLAN
Revisions: Date:
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE DETAIL '1' ON SHEET ET501
AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FRED WITH (2) CAT6A CABLES.
6" X 4" EXISTING CABLE TRAY. SEGREGATE EXISTING SYSTEMS AND DEMOLISH.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON ET501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET ET701, WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO CONDUIT
SLEEVES [(2)4", MINIMUM] WITH APPROPRIATE FIRE-PROOFING AND CAULKING TO
PASS THROUGH WALL. WHERE EXISTING CABLE TRAY AND/OR SLEEVES ARE
DISCOVERED, EVALUATE CONDITION AND RACEWAY CAPACITY; IF CABLE TRAY
AND/OR SLEEVES APPEAR TO BE REUSABLE, NOTIFY COR FOR POSSIBLE REUSE.
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250" (6.35mm) (4) CAT6A CABLES WITH AN 0.250" (6.35mm) OD OR SMALLER CAN
WAP
WAP
180°
180°
0°
180°
180°
AREA SHOWN
BLDG 018
A B C D E F G H I J K L M N
018ET402a
018ET402a
TYP.
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE
SERVED FROM TELECOMMUNICATIONS ROOM D-214A.
TYP.
018ET402a
018ET402a
018ET402b
018ET402b
BLDG 111
BLDG 017: SEE SHEET 017ET102
BLDG 018
BLDG 016: SEE SHEET 016ET102
BLDG 018
BLDG 018
CHIEF OFFICE
D.203
OFFICE
D.201
OFFICE
D.209
TOILET
D.209A
OFFICE
TOILET
STAIR #1
OFFICE
D.202
INFECTION CONTROL
OFFICE
D.204
OFFICE
D-215B
OFFICE
D-217
STAIR # 2
OFFICE
D-212B
OFFICE
D-280D
D-212C
OFFICE SUPPORT
D-212A
CHIEF OFFICE
D-218
HOUSEKEEPING AID
D-219
D-215
CORRIDOR
CORRIDOR 01
BIO-MED STOR.
D-213
CORRIDOR
SHAFT
D-214T
ELEVATOR
D.230
OFFICE
D-221
SHAFT
D-214AA
CHIEF OFFICE
D.223
TOILET
D.210A
STAFF OFFICE
D.212
STAFF OFFICE
D.210
STAFF OFFICE
D.208
STAFF OFFICE
D.206
TOILET
D.206A
CORRIDOR
D.232
BIO-MED STOR.
D-214
TR
D-214A
CORRIDOR 03
WAITING ROOM
CHIEF'S OFFICE
RECEPTIONIST /
SECRETARY
DARK ROOM
PANORAMIC X-RAY
RESIDENCE OFFICE
STORAGE
OPERATORY #1
OPERATORY #2
SOILED
STAFF DENTIST
OPERATORY #3
OPERATORY #4
OPERATORY #5
OPERATORY #6
OPERATORY #7
OPERATORY # 8
STAIRS
RESIN / CASTING
MECHANICAL ROOM
STERILE DENTAL
STORAGE
BREAKROOM
JANITOR'S CLOSET
LABORATORY
CONFERENCE/
CLASSROOM
WOMEN'S LOCKERS
MEN'S LOCKERS
MEN'S TOILET
WOMEN'S TOILET
N4
N4
N4
N4
N4
N4
N4
N4 N4
N4
N4
N4
N4
N4
N4
N4 N4
N4
N4 N4
N4
N4
N4
N4 N4
N4
N2
N2
N4 N4
N2
N4 N2
N2
N2
N2
N2
N2
N2N2
N2 N4
N4N4
N4N4N4
N4
N2 N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2 N2
N2 N2 N2
N2
N2
N2
N2 N2
N2
N2
N2
N2
N2
N2
DD1
DD1
N2
DD3
DD3
DD3DD3
DD1
DD1
DD1
DD3
DD1DD1DD3
DD3
DD1
DD1
DD1
DD1
DD5
DD3
DD1
DD3
DD3 DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD1
DD1
DD4
DD4
DD4
DD4
DD6
DD4
DD3
DD3
DD4
DD3
DD3
DD4
DD3DD3
DD5
DD4
DD4
DD4
DD3
DD4DD6
DD4
DD4
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3DD3
DD1
DD3
DD3
DD1
DD3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1 /2
:5
:5 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
018ET102
BLDG 018 - LEVEL 02 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
TRUE
NORTH
4'0 8' 16'
PROJECT
NORTH
- 1/8" = 1'-0"
1 BLDG 018 - LEVEL 02 - TELECOMMUNICATIONS PLAN
Revisions: Date:
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE DETAIL '1' ON SHEET ET501
AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FRED WITH (2) CAT6A CABLES.
4" X 2" EXISTING CABLE TRAY. SEGREGATE EXISTING SYSTEMS AND DEMOLISH.
12" X 2" EXISTING CABLE TRAY. SEGREGATE EXISTING SYSTEMS AND DEMOLISH.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON ET501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET ET701, WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO CONDUIT
SLEEVES [(2)4", MINIMUM] WITH APPROPRIATE FIRE-PROOFING AND CAULKING TO
PASS THROUGH WALL. WHERE EXISTING CABLE TRAY AND/OR SLEEVES ARE
DISCOVERED, EVALUATE CONDITION AND RACEWAY CAPACITY; IF CABLE TRAY
AND/OR SLEEVES APPEAR TO BE REUSABLE, NOTIFY COR FOR POSSIBLE REUSE.
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
WAP WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAPWAP
WAP
WAP
WAP
AREA SHOWN
BLDG 018
A B C D E F G H I J K L M N
G.U. O.R. 1
CONTROL ROOM
338A
DARK ROOM
SOILED UTILITY
CLEAN UTILITY
CONTROL ROOM
331 A
G.U O.R. 2
STAIR HALL 2
G.U. WORK ROOM
MEN'S LOCKER ROOM
329B
WOMEN'S LOCKER ROOM
329C
TOILET
329A
HOUSEKEEPING
327A
CONFERENCE ROOM
OFFICE
OFFICE
OFFICE
STORE ROOM
EXAM ROOM
RECEPTION
TOILET
330A
MAIL ROOM
324A
STORAGE (FLOOR
PENATRATIONS)
BATHROOM
OFFICE
E.M.S. CLOSET
O.R. SUPPLIES
OFFICE
E.M.S. STORE ROOM
EQUIPMENT STORAGE
314A TOILET
312F
COPY
312B
KICH.
312G STAFF
LOUNGE
312C
G.U. EXAM ROOM
G.U. WAITING ROOM
OFFICE
SURGICAL
CLINIC
STAIR HALL 3
OFFICE
303OBSERVATION ROOM
305POST ASSESMENT ROOM
307OFFICE
WAITING ROOM
CHECK-IN
OFFICE
321B
OFFICE
321A
O.R. BIO. WASTE
319 UTILITY ROOM
STAFF
LOUNGE
TOILET
208A
TOILET
306A
PRE-ASSESMENT ROOM
ELEVATOR SHAFT
TOILET
311A
EQUIPMENT STORAGE
314B
STAIR HALL 01
001G
ANTE CORRIDOR
CORRIDOR 04
WAITING ROOM
CORRIDOR 03
CORRIDOR 01
CORRIDOR 08
CORRIDOR 07
CORRIDOR 02
CORRIDOR 06
M.C. 01
018ET403
018ET403
TYP.
TR
314CA
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE
SERVED FROM TELECOMMUNICATIONS ROOM 314CA.
TYP.
BLDG 111
BLDG 017: SEE SHEET 017ET103
BLDG 018
BLDG 016: SEE SHEET 016ET103
BLDG 018
BLDG 018
018ET403
018ET403
N4
N4
N4
N4
N2
N2
N2 N2
N2
N2
N2
N2
N2
N2 N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2
N2 N2
N2
N2 N2
N2
N2
N2
N2
N2
N2
N2N2N2
N2
N2
N2
N2
N2
N2N2
N2
N2 N2
N2
N2N2
N2
N2
N2
N2
N4
DD3
DD3
DD3
DD3
DD3
DD3
DD3DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD3
DD6
DD3
DD3
DD3
DD5
DD6
DD4
DD3
DD3
DD3
DD3
DD3
DD2
DD3
DD3
DD3
DD3
DD3
DD3
DD3DD3DD3
DD3
DD3
DD3
DD2
DD3
DD4
DD3
DD3
DD3
DD3DD3
DD2DD2
DD3
DD3DD3
DD3
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1 /2
:5
:0 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
018ET103
BLDG 018 - LEVEL 03 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
TRUE
NORTH
4'0 8' 16'
PROJECT
NORTH
- 1/8" = 1'-0"
1 BLDG 018 - LEVEL 03 - TELECOMMUNICATIONS PLAN
Revisions: Date:
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE DETAIL '1' ON SHEET ET501
AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FRED WITH (2) CAT6A CABLES.
4" X 6" EXISTING CABLE TRAY. SEGREGATE EXISTING SYSTEMS AND DEMOLISH.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON ET501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET ET701, WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO CONDUIT
SLEEVES [(2)4", MINIMUM] WITH APPROPRIATE FIRE-PROOFING AND CAULKING TO
PASS THROUGH WALL. WHERE EXISTING CABLE TRAY AND/OR SLEEVES ARE
DISCOVERED, EVALUATE CONDITION AND RACEWAY CAPACITY; IF CABLE TRAY
AND/OR SLEEVES APPEAR TO BE REUSABLE, NOTIFY COR FOR POSSIBLE REUSE.
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
WAP WAP WAP
WAP
1VA
W A
P
WAP
A B C D E F G H I J K L
M N
O
019ET400
019ET400
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE SERVED
FROM TELECOMMUNICATIONS ROOM C-104 ON LEVEL 01.
1 1
B L D
G
B L D
G
: S
E E
S H
E E
T
E
T
BLDG 111: SEE SHEET 111ET100B
BLDG 019
UNNEXCAVATED 03
CRAWL SPACE 01
CRAWL SPACE 02
UNEXCAVATED 03
STORAGE
C-005
MECHANICAL ROOM
C-002A
M.C.
MECHANICAL ROOM
C-002
ELECTRICAL ROOM
C-003
C E
N T
E R
S T
A
IR
H A
L L
TANK ROOM
C-001
M.C. 01
WATER SUPPLY
C-004
ELEVATOR LOBBY
STAIR HALL 1
WATER
CLOSET
C-001A
WATER CLOSET
C-001B
VESTIBULE
TUNNEL CORRIDOR
CT-003
TUNNEL CORRIDOR
TUNNEL CORRIDOR
CT-004
UNEXCAVATED 01
CC101B
AREA SHOWN
BLDG 019
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1
/2
:1
:0 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
019ET100
BLDG 019 - LEVEL 00 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
- 1" = 10'-0"
1 BLDG 019 - LEVEL 00 - TELECOMMUNICATIONS PLAN 0 10' 20'
PROJECT
NORTH
TRUE
NORTH
Revisions: Date:
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250" (6.35mm) (4) CAT6A CABLES WITH AN 0.250" (6.35mm) OD OR SMALLER CAN
BE INSTALLED IN A 3/4” CONDUIT SUPPORTING A 40% FILL RATIO.
14. ALL COPPER AND FIBER OPTIC CABLES SHALL BE SUPPORTED BY J HOOKS SPACED
48" TO 60" APART. J HOOKS SHALL NOT EXCEED 40% FILL RATIO.
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE SHEET DETAIL '1' ON SHEET
ET501 AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FED WITH (2) CAT6A CABLES.
CAT6A FEEDING LEVEL 00 TO BE ROUTED THROUGH VERTICAL FIRE STOP SLEEVE
PENETRATION BACK TO TR INDICATED ON "TELECOMMUNICATIONS WAO AND CABLE
TRAY SCHEDULE" ON SHEET ET701.
FIRE ALARM FIBER-OPTIC CABLING FROM NODE 14 TO BE ROUTED WITH PATH A FIBER
BACKBONE TO DATA CENTER. REFERENCE SHEET 19-TN100 FOR ADDITIONAL
INFORMATION.
1VA
WAP
WAP
WAP
WAP
WAP
WAP
WAP
WAPWAP
A B C D E F G H I J K L
M N
O
019ET401
019ET401
TYP.
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE
SERVED FROM TELECOMMUNICATIONS ROOM C-104.
2 2
019ET401
019ET401
B L D
G
B L D
G
: S
E E
S H
E E
T
E
T
BLDG 111: SEE SHEET 111ET101
BLDG 019
TYP.
SOUTH STAIR HALL
STORAGE ROOM
C-120A1
CORRIDOR 03
OFFICE
C-123A
OFFICE
C-123B
OFFICE
C-123
OFFICE
120A
LIBRARY
C-120
OFFICE
C-119
SMI/BIOMED WORKSHOP
C-114
CORRIDOR 04
CORRIDOR 5
MEN'S TOILET
C-124B
WOMEN'S
TOILET
C-124A
STORAGE
C-124C
WOMEN'S TOILET
C-125
WOMEN'S VEST.
C-125
SMI/BIOMED
STORAGE
C-125A
VESTIBULE 01
HOUSEKEEPING
C-126A
RECREATION STORAGE
C-126
VESTIBULE 02
CORRIDOR 01
UNION OFFICE
C-101
OFFICE
C-102
STORAGE ROOM
C-103
TR
C-104
BIO. MED. SUPERVISOR
C-114A
ELECTRONICS SHOP
ELECTRONICS SHOP
SUPERVISOR OFFICE
C-110
VOLUNTEER SVC. COMPUTER
SHOP
C-109
OFFICE
C-109A
STORAGE
C-106
STORAGE
C-105
STORAGE
C-105A
VOLUNTEER SERVICE OFFICE
VOLUNTEER WORKSHOP
C-152
VOLUNTEER OFFICE
C-151
WEST STAIR HALL
VESTIBULE 03
CONENCTING CORRIDOR
CC-103
NODE 01
CC-104
CONNECTION
CORRIDOR
CC-105
ELEVATOR LOBBY
CTR. NORTH STAIR HALL
CC101A
COURTYARD
C-153
CORRIDOR 6
CORRIDOR 7
CORRIDOR 2
C E
N T
E R
S T
A
IR
H A
L L
DD4
N2
DD3
N2
DD4
N2
DD4
N2
DD6
N2
DD4
N2
DD4
N2
DD3
N2
DD4
N2
DD4
N2
DD4
N2
DD4
N2
DD4
N2
DD4
N2
DD3
N2 DD3
N2
DD2
N2
DD3
N2
DD3
N2
DD3
N2
DD3
N2
DD3
N2
DD6
N2
DD3
N2
DD2
N2
DD1
N2
DD4
N2
DD2
N2
DD3
N2
DD4
N2
DD5
N2
DD3
N2
DD4
N2
DD3
N2
DD3
N2
DD5
N2
DD6
N2
DD5
N2
DD6
N2
DD1
N2
DD1
N2
DD3
N2
AREA SHOWN
BLDG 019
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1
/2
:1
:4 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
019ET101
BLDG 019 - LEVEL 01 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
0 10' 20'
PROJECT
NORTH
- 1" = 10'-0"
1 BLDG 019 - LEVEL 01 - TELECOMMUNICATIONS PLAN
TRUE
NORTH
Revisions: Date:
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250" (6.35mm) (4) CAT6A CABLES WITH AN 0.250" (6.35mm) OD OR SMALLER CAN
BE INSTALLED IN A 3/4” CONDUIT SUPPORTING A 40% FILL RATIO.
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE SHEET DETAIL '1' ON SHEET
ET501 AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FED WITH (2) CAT6A CABLES.
4" X 6" EXISTING CABLE TRAY. SEGREGATE EXISTING SYSTEMS AND DEMOLISH.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON ET501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET ET701, WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO CONDUIT
SLEEVES [(2) 4", MINIMUM] WITH APPROPRIATE FIRE-PROOFING AND CAULKING TO
PASS THROUGH WALL. WHERE EXISTING CABLE TRAY AND/OR SLEEVES ARE
DISCOVERED, EVALUATE CONDITION AND RACEWAY CAPACITY; IF CABLE TRAY
AND/OR SLEEVES APPEAR TO BE REUSABLE, NOTIFY COR FOR POSSIBLE REUSE.
PROVIDE (1) VERTICAL FIRE STOP SLEEVE PENETRATION FOR ROUTING CAT6A
CABLING DOWN TO LEVEL 00.
WAP
WAP WAP
WAP WAP
WAP
WAP
WAPWAPWAP
WAP
A B C D E F G H I J K L
M N
O
019ET402
019ET402
TYP.
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE
SERVED FROM TELECOMMUNICATIONS ROOM C-208.
2 2
019ET402
019ET402
B L D
G
B L D
G
: S
E E
S H
E E
T
E
T
BLDG 111
BLDG 019
TYP.
OFFICE
C-217
CORRIDOR 06
OFFICE
C-218
OFFICE
C-219
STORAGE
C-218A
OFFICE
C-220
ALCOVE 01
OFFICE
C-220A
OFFICE
200A TOILET
200B
ADMIN SUPPORT
C-200
OFFICE
C-201
OFFICE
C-202
OFFICE
C-202A
EEO OFFICE
C-203
EMS STORAGE
C-204
BATHROOM
C-203A
BEREAVEMENT ROOM
C-205
CORRIDOR 1
CORRIDOR 04
UNIFORM ROOM
C-206
STORAGE
C-206A
MEN'S TOILET
C-207
STORAGE
C-207A
STORAGE
C-206A1
WEST STAIR HALL
OFFICE
C-206A
CHIEF OFFICE
C-210A
OFFICE
C-211
OFFICE
C-212A
VESTIBULE
OFFICE
C-212B
CORRIDOR 2
CORRIDOR 03
CORRIDOR 01
ELECTRICAL CLOSET
C-209
TR
C-208
EMS CLOSET
C-214
ELECTRICAL
CLOSET
C-213
OFFICE
C-215
OFFICE
C-216A
OFFICE
C-216
WOMEN'S TOILET
C-215A
SOUTH STAIR HALL
OFFICE
C-210CENTER STAIR HALL
DD4
N2
DD6
N2
DD3
N2
DD6
N2
DD3
N2
DD6
N2 DD3
N2
DD4
N2
DD6
N2
DD6
N2
DD4
N2
DD4
N2
DD3
N2
DD5
N2
DD3
N2
DD3
N2
DD3
N2
DD4
N2
DD4
N2
DD3
N2
DD3
N2
DD3
N2
DD3
N2
DD2
N2
DD3
N2
DD3
N2
DD3
N2
DD2
N2
DD3
N2
DD2
N2
DD3
N2DD3
N2
DD4
N2
DD3
N2 DD3
N2
DD4
N2
DD6
N2
DD3
N2
DD6
N2
DD4
N2
AREA SHOWN
BLDG 019
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1
/2
:1
:4 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
019ET102
BLDG 019 - LEVEL 02 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
0 10' 20'
PROJECT
NORTH
- 1" = 10'-0"
1 BLDG 019 - LEVEL 02 - TELECOMMUNICATIONS PLAN
TRUE
NORTH
Revisions: Date:
KEY NOTES
GENERAL NOTES
KEY PLAN
1. ALL EXISTING EQUIPMENT MAY NOT BE SHOWN FOR CLARITY. CONTRACTOR SHALL
FIELD VERIFY ALL DEVICES AND ASSOCIATED CABLING AS REQUIRED. ALL RACEWAYS
AND CABLING ASSOCIATED WITH EQUIPMENT TO BE DEMOLISHED SHALL BE
DEMOLISHED BACK TO ITS SOURCE, UNLESS OTHERWISE NOTED.
2. PROTECT ALL EXISTING WORK FROM DAMAGE DURING CONSTRUCTION. ANY
DAMAGED MATERIALS, SYSTEMS, COMPONENTS, AND FINISHES SHALL BE REPAIRED
OR REPLACED AT THE EXPENSE OF THE CONTRACTOR TO THE ACCEPTANCE OF THE
OWNER.
3. SEAL ALL INTERIOR WALL AND CEILING PENETRATIONS TO MATCH EXISTING FIRE
RATING OR NEW FIRE RATING. COORDINATE WITH ARCHITECTURAL DRAWINGS AS
REQUIRED.
4. ALL TELECOMMUNICATIONS CABLING CATEGORY 6 AND BELOW SHALL BE REMOVED
AND REPLACED WITH CAT6A PORTS AND CABLE QUANTITIES INDICATED, UNLESS
NOTED OTHERWISE.
5. TELECOMMUNICATIONS CABLES SHALL BE ROUTED IN EXISTING PATHWAY VACATED
BY EXISTING CABLING AS CONDUIT FILL ALLOWS. PROVIDE ADDITIONAL RACEWAYS
TO EXTEND TO ASSOCIATED TR AS REQUIRED. CONDUIT FILL RATIO SHALL NOT
EXCEED 40%.
6. TELECOMMUNICATIONS WAO UPGRADE SHALL INCLUDE, BUT IS NOT LIMITED TO
REMOVING AND DISPOSING OF EXISTING CABLING, JACKS AND FACEPLATES AS
REQUIRED; PROVIDING ALL LABOR, MATERIALS, TOOLS, TEST INSTRUMENTS, AND
CONSUMABLES REQUIRED FOR INSTALLATION, TERMINATION, TESTING, LABELING,
AND CERTIFICATION OF A FULLY FUNCTIONAL CATEGORY 6A OUTLET WITH PORT
QUANTITY INDICATED.
7. WHEN PROVIDING A WAO IN LOCATIONS WHERE AN EXISTING WAO CURRENTLY DOES
NOT EXIST, PROVIDE (1) 4-INCH SQUARE BACKBOX WITH SINGLE-GANG REDUCING
MUD RING AND (1) 1-1/4" CONDUIT EXTENDING FROM BACKBOX TO ACCESSIBLE
CEILING SPACE. ONCE IN ACCESSIBLE CEILING SPACE, CABLING SHALL EXTEND TO
ITS ASSOCIATED TR VIA CABLE TRAY; UTILIZE J-HOOKS EVERY 48” WHEN
TRANSITIONING TO OR FROM CABLE TRAY. IF CABLE TRAY IS NON-EXISTENT, EXTEND
HORIZONTAL CABLING FROM WAO TO TR VIA J-HOOKS ONLY.
8. PROVIDE PULL BOXES SIZED PER ANSI/TIA-569 AT 100-FT INTERVALS IN STRAIGHT
CONDUIT RUNS, OR CONDUIT CONTAINING BENDS TOTALING MORE THAN 180
DEGREES.
9. PROVIDE CONDUITS AND SLEEVES AS REQUIRED FOR ROUTING AND INSTALLATION OF
HORIZONTAL AND BACKBONE CABLING. PROVIDE FIRE-STOP MATERIALS TO SEAL IN
AND AROUND CONDUIT PER CODE. REFER TO ARCHITECTURAL DRAWINGS FOR
PARTITION TYPES AND WALL HEIGHTS.
10. OUTLET LOCATIONS ARE APPROXIMATE. DETERMINE EXACT LOCATIONS IN FIELD;
DOCUMENT VARIANCES BASED ON AS-BUILT DRAWINGS.
11. ALL DATA CABLING SHALL BE SEGREGATED FROM OTHER SPECIAL SYSTEMS
INCLUDING, BUT NOT LIMITED TO, SECURITY, FIRE ALARM, AND NURSE CALL SYSTEMS.
WHEN ROUTED THROUGH CONDUIT, DATA CABLING SHALL HAVE ITS OWN RACEWAY.
WHEN DATA CABLING IS ROUTED THROUGH A COMMON SPECIAL SYSTEMS CABLE
TRAY, CABLING SHALL BE BUNDLED WITH LIKE SYSTEMS; ADDITIONALLY, CABLE
TRAYS SHALL BE PROVIDED WITH TRAY DIVIDERS AS REQUIRED TO SEGREGATE
SYSTEMS FROM ONE ANOTHER.
12. FIBER-OPTIC CABLING ROUTES AND ASSOCIATED RACEWAYS/CABLE TRAY ARE
DIAGRAMMATICAL. COORDINATE EXACT ROUTING WITH EXISTING CONDITIONS,
ARCHITECTURAL FEATURES, MECHANICAL DUCTWORK, PIPING, EQUIPMENT, AND ANY
OTHER OBSTRUCTIONS PRIOR TO INSTALLATION.
13. THE CONTRACTOR SHALL BID AND INSTALL CAT6A CABLE WITH AN OD NOT GREATER
THAN 0.250" (6.35mm) (4) CAT6A CABLES WITH AN 0.250" (6.35mm) OD OR SMALLER CAN
BE INSTALLED IN A 3/4” CONDUIT SUPPORTING A 40% FILL RATIO.
PROVIDE TELECOMMUNICATIONS OUTLET WITH PORT QUANTITY SHOWN TO REPLACE
EXISTING TELECOMMUNICATIONS OUTLET; EXISTING OUTLET CONDUIT SHALL REMAIN
AND BE UTILIZED TO FEED NEW CABLING; REFERENCE SHEET DETAIL '1' ON SHEET
ET501 AND THE GENERAL NOTES ON THIS SHEET FOR ADDITIONAL INFORMATION.
COORDINATE WITH VA FOR EXACT OUTLET PLACEMENT.
EXISTING WIRELESS ACCESS POINT TO BE RE-FED WITH (2) CAT6A CABLES.
4" X 6" EXISTING CABLE TRAY. SEGREGATE EXISTING SYSTEMS AND DEMOLISH.
PROVIDE CABLE TRAY AS INDICATED. REFERENCE DETAIL "6" ON ET501 AND
TELECOMMUNICATIONS WAO AND CABLE TRAY SCHEDULE ON SHEET ET701, WHERE
WALL EXTENDS TO CEILING, CABLE TRAY SHALL STOP AND TRANSITION TO CONDUIT
SLEEVES [(2)4", MINIMUM] WITH APPROPRIATE FIRE-PROOFING AND CAULKING TO
PASS THROUGH WALL. WHERE EXISTING CABLE TRAY AND/OR SLEEVES ARE
DISCOVERED, EVALUATE CONDITION AND RACEWAY CAPACITY; IF CABLE TRAY
AND/OR SLEEVES APPEAR TO BE REUSABLE, NOTIFY COR FOR POSSIBLE REUSE.
WAP WAPWAP
WAP
AREA SHOWN
A B C D E F G H I J K L M N O
PIPE BASEMENT
STORAGE
B-004
CORRIDOR 01
ELEC RM 03
B-006
STORAGE
B-007
MECHANICAL
ROOM
B-005
PIPE BASEMENT
PIPE BASEMENT
ELECTRICAL
ROOM 01
B-003
STAIR HALL 01
TANK ROOM
B-001
STEAM ROOM
B-002
ELECTRICAL
ROOM 02
B-003A
PIPE BASEMENT
UNEXCAVATED
VESTIBLUE 01
TUNNEL
DATA OUTLETS AND DEVICES IN THIS AREA SHALL BE SERVED
FROM TELECOMMUNICATIONS ROOM B-122 ON LEVEL 01.
2 2
B L D
G
S E
E S
H E
E T
E
T
B L D
G
B L D
G
B L D
G
S E
E S
H E
E T
E
T
REFERENCE SHEET 020ET401
FOR ADDITIONAL INFORMATION
N2
DD3
BLDG 020
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
FULLY SPRINKLERED
Office of
Construction and Facilities
Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD
A/E:
STAMPCONSULTANT/DISCIPLINE
321 4 5 6 7 8 9 10
ENGINEERING DISCIPLINE:
SPEES DESIGN BUILD
23830 PACIFIC HIGHWAY S. SUITE 300
KENT, WA 98032
/1
/2
:2
:4 a m
B
IM
/6
A
-2
-7
V
A H
V E
H R
M i n fr a s tr u c tu re u p g ra d e s
C a s tl e
P o in t/ V
A C
P
E L S
D B
.r v t
020ET100
BLDG 020 - LEVEL 00 - TELECOMMUNICATIONS
PLAN
KG RTS/JNV
100% CONSTRUCTION
DOCUMENTS
11/07/2025
620A4-22-700EHRM INFRASTRUCTURE
UPGRADES - CASTLE POINT
VA HUDSON VALLEY MEDICAL CENTER
41 CASTLE POINT ROAD, WAPPINGERS FALLS, NY 12590
- 1/8" = 1'-0"
1 BLDG 020 - LEVEL 00 - TELECOMMUNICATIONS PLAN 4'0 8' 16'
PROJECT
NORTH
TRUE
NORTH
Rev…
This is the start of the file's text. The full file is on GovTribe.