This file contains drawings related to a federal solicitation for repair work on a medical training facility. The solicitation number is W50S6Y24B0001 and was issued by the Department of the Army Florida Army National Guard for repair of Medical Training Facility Bldg 1002B. The opportunity type is a solicitation and the 11MB PDF file attached contains volume 3 of the drawings package with details for the repair work on the facility. Offerors should review the drawings and specifications contained in the 3 volumes of attachments to understand the full scope of repairs required prior to submitting a response to the solicitation. The response due date and anticipated award date are not provided in this file attachment.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

T

A, AMP

AC

AF

AHU

ANN

AO

AP

AT

AFF

AFC

ELEV ELEVATOR

AIC

POWER CONTROL MONITORING SYSTEM

AIR HANDLING UNIT

AFG ABOVE FINISHED GRADE

GFCI

ISOLATED GROUND

WYE

AMPERE

AMPERE INTERRUPTING CAPACITY

RECTIFIER

TELEVISION

ABOVE FINISHED FLOOR

ELECTRIC HEATING COIL

ELECTRIC HEAT TRACE

FIRE ALARM CONTROL PANEL

HAND-OFF-AUTOMATIC

INTERCOMMUNICATION

FLUORESCENT

IMPEDANCE

TRANSFORMER

WATT

VARIABLE FREQUENCY DRIVE

VOLTMETER

VOLT AMPEREALTERNATING CURRENT

AMPERE FRAME

ANNUNCIATOR

ANALOG OUTPUT

ANNUNCIATOR POINT

AMPERE TRIP

CIRCUIT BREAKER

DATA GATHERING PANEL

IESNA

EXISTING TO REMAIN

POWER TRANSFORMER

PAN-TILT-ZOOM

PHASE

GROUND FAULT INTERRUPTER

AWG AMERICAN WIRE GAUGE

DIRECT CURRENT

DISTRIBUTION PANEL

DOUBLE POLE DOUBLE THROW

EMPTY CONDUIT

PRIVATE BRANCH EXCHANGE

SYSTEM CONTROL PANEL

TERMINAL

ELECTRIC WATER COOLER

DIGITAL INPUT

DISCONNECT

DIGITAL OUTPUT

FULL LOAD AMPERES

HIGH VOLTAGE

HIGH PRESSURE SODIUM

HANDHOLE

GROUND

GAUGE

FULL VOLTAGE

FEEDER

LIGHTING

WYE-DELTA

WATTMETER

CONDUIT

DIRECT DIGITAL CONTROL PANEL

POLYVINYL CHLORIDE

RADIO FREQUENCY INTERFERENCE

ROOT MEAN SQUARE

SWITCHBOARD

TERMINAL BOX OR TERMINAL BOARD

TIME DELAY

TELEPHONE TERMINAL

VOLT, VOLTAGE

DOUBLE POLE SINGLE THROW

ELECTRICAL METALLIC TUBING

HAZARDOUS

QUANTITY

SHIELDED TWISTED PAIR

DIAMETER

POLE

POWER FACTOR

HERTZ

HEIGHT

HORSEPOWER

WEATHERPROOF

CONTROL SWITCH

POSITIVE

RECEPTACLE

RIGID GALVANIZED STEEL

SINGLE POLE

START-STOP

SWITCH

TELEPHONE

DEMAND METER

DRY TYPE

FOOTCANDLE

HIGH POWER FACTOR

EQUIPMENT

ENCLOSURE

STANDARD

FUTURE

EQ,

EQUIP

TRANSIENT VOLTAGE SURGE

SUPPRESSOR

GFGI

NORMALLY CLOSED

NATIONAL ELECTRICAL CODE

NORMALLY OPEN

NON-REVERSING

MAIN CIRCUIT BREAKERMCB

NEUT

MH MANHOLE

PP POWER POLE

LONG, SHORT, INSTANTANEOUS

AVAILABLE FAULT CURRENT

GFE GOVERNMENT FURNISHED EQUIPMENT

SMF SINGLE MODE FIBER

TMGB

ESS ELECTRONIC SECURITY SYSTEM

ATS AUTOMATIC TRANSFER SWITCH

RVSS REDUCE VOLTAGE SOLID STATE

HPP HORIZONTAL PATCH PANEL

TGB

FPP FIBER PATCH PANEL

NIC NOT IN CONTRACT

BB BACKBONE

BLDG BUILDING

NTS NOT TO SCALE

BC

CCTV

CB

C

COND

CO

CONN

CONT

CONV

CPU

CS

CR

CU

CT

DC

DDCP

DEM

DGP

DI

DIA

DISC

DPNL, DP

DM

DO

DPDT

DPST

DT

E.C.

EHC

EMT

ENCL

EHT

EWC

FAAP

FACP

FC

FDR

FLA

FLUOR

FUT

FV

GA

GFI

HAZ

HH

HOA

HP

HPF

HPS

HT

HV

HVAC

HZ

IC

IG

KCM

KVA

KVAR

KW

KWH

LRA

LSI

LTG

MAX

MCC

MCP

MDT

MEQ

MIN

MLO

MTG

N/C

NEC

NO

N/O

NR

P

PABX

PBX

PCMS

PF

PH

POS

PT

PTZ

PVC

QY, QTY

REC

RECT

RFI

RGS

RMS

SCP

SP

S/S

ST

STD

STP

SW

SWBD

TB

TD

TELE

TERM

TT

TV

TVSS

TYP

V

VA

VM

VFD

W

WM

WP

XFMR

Y-D

Y

Z

OVHD

UON UNLESS OTHERWISE NOTED

DEMAND

GROUND FAULT CIRCUIT INTERRUPTER

FIRE ALARM ANNUNCIATOR PANEL

CURRENT TRANSFORMER

COPPER

CENTRAL PROCESSING UNIT

CONTROL RELAY

CONVENIENCE

CONTINUOUS

CONNECTION

CONDUCTOR

CONDUIT ONLY

NEUTRAL

BARE COPPER

TYPICAL

MINIMUM

CLOSED CIRCUIT TELEVISION

KILOWATT

ETR

COMM COMMUNICATION

BKR

BEPB

BREAKER

MAIN LUGS ONLY

MECHANICAL EQUIPMENT

MAIN DISTRIBUTION TERMINAL

MOTOR CIRCUIT PROTECTOR

MOTOR CONTROL CENTER

MAXIMUM

MOUNTING

LOW VOLTAGELV

LOCKED ROTOR AMPERE

KILOWATT HOUR

KILOVOLT AMPERES-REACTIVE

KILOVOLT AMPERES

KILOVOLT

THOUSAND CIRCULAR MILLS

KILOAMPERESKA

KV

NUMBER

ON CENTER, OVERCURRENTOC

OVERHEAD

CKT

CMH

GOVERNMENT FURNISHED,

GOVERNMENT INSTALLED

ILLUMINATING ENGINEERING

SOCIETY OF NORTH AMERICA

TELECOMMUNICATIONS MAIN

GROUNDING BUSBAR

TELECOMMUNICATIONS GROUNDING

BUSBAR

PRIVATE AUTOMATIC BRANCH

EXCHANGE

SHUNT TRIP

CHH COMMUNICATION HANDHOLE

BBV BACKBONE VOICE PATCH PANEL

BUILDING ENTRANCE PROTECTION BLOCKS

BUILDING ENTRANCE FIBER PATCH PANEL

HEATING, VENTILATION AND AIR

CONDITIONING

BEFPP

CIRCUIT

COMMUNICATIONS MAN HOLE

MDP MAIN DISTRIBUTION PANEL

SS SOLID STATE

TM THERMAL MAGNETIC

LSIG LONG, SHORT, INSTANTANEOUS AND

GROUND FAULT

PB PULL BOX

MGB MAIN GROUNDING BUSBAR

G, GND

LED LIGHT EMITTING DIODE

SPD SURGE PROTECTION DEVICE

RECESSED ROUND WALL WASHER. TRIANGLE POINTS TO WASHED WALL

SEMI-RECESSED RECTANGULAR WALL WASHER. TRIANGLE POINTS TO WASHED WALL

LED OR COMPACT FLUORESCENT WALL MOUNTED FIXTURE

ROUND PENDANT LIGHT FIXTURE

NEW POWER POLE

EXISTING POWER POLE

PRIMARY UNDERGROUND ELECTRIC CABLE

D1 b

LED FIXTURE WITH INTEGRAL WITH BATTERY PACK.

LED WALL MOUNTED FIXTURE WITH BATTERY PACK.

FIXTURE WITH DUAL BALLASTS FOR INBOARD/OUTBOARD SWITCHING OF LAMPS.

LETTERS CORRESPOND TO SWITCH.

a,b

EPu

EPo PRIMARY OVERHEAD ELECTRIC CABLE

ESu SECONDARY UNDERGROUND ELECTRIC CABLE

TRANSFORMER

LIGHT BOLLARD

GUY WIRE AND ANCHOR PIN

E

MANHOLE OR HANDHOLE:

E- ELECTRICAL, C-COMMUNICATIONS, S- SECURITY, L-LIGHTING

EXISTING PRIMARY OVERHEAD ELECTRIC CABLEOW

LED OR COMPACT FLUORESCENT FIXTURE. SUBSCRIPT "D1"

DENOTES FIXTURE TYPE D1, SUBSCRIPT "b" DENOTES CONTROLLED BY SWITCH b

(TYP FOR ALL LIGHTING FIXTURES).

WALL MOUNTED EXIT SIGNS WITH ARROWS AS INDICATED (SHADING INDICATES

ILLUMINATED FACE(S) OF SIGN) WITH BATTERY PACK.

CEILING OR PENDANT MOUNTED EXIT SIGNS WITH ARROWS AS INDICATED (SHADING

INDICATES ILLUMINATED FACE(S) OF SIGN) WITH BATTERY PACK.

LIGHT POLE

EXISTING LIGHT POLE

ELECTRICAL ABBREVIATIONS

SITE ELECTRICAL SYMBOLS

LIGHTING SYMBOLS

ELECTRIC VEHICLE CHARGING

STATIONEV

POLE MOUNTED TRANSFORMER

ESo

2'x4' RECESSED FIXTURE (DRAWN TO SCALE)

2'x4' EMERGENCY FIXTURE WITH BATTERY PACK.

4' RECESSED FIXTURE (DRAWN TO SCALE)

4' EMERGENCY FIXTURE WITH BATTERY PACK.

STRIP FIXTURE

STRIP EMERGENCY FIXTURE WITH BATTERY PACK

4' WALL MOUNTED FIXTURE WITH BATTERY PACK

4' WALL MOUNTED FIXTURE

DIRECT/INDIRECT PENDANT MOUNTED FIXTURE

DIRECT/INDIRECT PENDANT MOUNTED EMERGENCY FIXTURE WITH BATTERY PACK.

2' WALL MOUNTED FIXTURE WITH BATTERY PACK.

2' WALL MOUNTED FIXTURE

SECONDARY OVERHEAD ELECTRIC CABLE

R

EXISTING POWER POLE TO BE REMOVED

R EXISTING AERIAL LINE(S) TO BE REMOVED

E UNDERGROUND ELECTRIC CABLE(S)

MTS MANUAL TRANSFER SWITCH

J

CR

X

J

CR

G

CORD REEL, 120V, 20A, CLASS 1 DIV 1 WITH EXPLOSION PROOF LED LIGHT.

CORD REEL, 120V, 20A, WITH GFCI 20A NEMA 5-20R CONNECTOR.

2'x2' RECESSED FIXTURE (DRAWN TO SCALE)

2'x2' EMERGENCY FIXTURE WITH BATTERY PACK.

OS

TS

OS

PC

J

J

J

3CS

SH

G

WALL MOUNTED TIMER SWITCH

JUNCTION BOX CONCEALED ABOVE FINISHED CEILING DESIGNATION:

SH - MOTORIZED SHADE SB - "SMART BOARD

PH - MECHANICAL FAN

PS - PROJECTOR SCREEN

JUNCTION BOX IN WALL WITH BLANK COVERPLATE. MOUNT 18" AFF TO

CENTER OF BOX UON.

CEILING MOUNTED RECEPTACLE. 125V, 20A, 1PH, 3-WIRE NEMA 5-20R RECEPTACLE.

CEILING MOUNTED DUAL TECHNOLOGY PASSIVE INFRARED/ULTRASONIC

OCCUPANCY SENSOR AND POWER PACK(S). BASIS OF DESIGN HAS

360 DEGREE DETECTION PATTERN.

WALL MOUNTED DUAL TECHNOLOGY PASSIVE INFRARED/ULTRASONIC

OCCUPANCY SENSOR AND POWER PACK(S). BASIS OF DESIGN HAS

360 DEGREE DETECTION PATTERN.

FLOOR MOUNTED JUNCTION BOX WITH BLANK COVERPLATE.

WIRING DEVICE SYMBOLS

G

WP

S

C

TV

EWC

WALL MOUNTED UON, DUPLEX RECEPTACLE - 125V, 20A, 1PH, 3-WIRE

NEMA 5-20R MOUNTED 18" AFF TO CENTER OF RECEPTACLE UON.

THE FOLLOWING SUBSCRIPTS APPLY TO ALL RECEPTACLE DEVICES:

= GROUND FAULT INTERRUPTER

= WEATHERPROOF ENCLOSURE, IN-USE COVER

= SWITCHED OUTLET - TOP OUTLET TO BE SWITCHED, BOTTOM

OUTLET UNSWITCHED

= COMPUTER RECEPTACLE - ISOLATED GROUND, ORANGE WITH

GREEN TRIANGLE

= TV RECEPTACLE - MOUNT RECEPTACLE AT 84", UON. COORDINATE

EXACT LOCATION WITH ARCHITECTURAL AND

COMMUNICATION DRAWINGS

= ELECTRIC WATER COOLER RECEPTACLE. MOUNT AT 18' AFF IN

WATER COOLER HOUSING. RECEPTACLE IS GFCI TYPE.

DAYLIGHT SENSOR

TOGGLE SWITCH - LOWER CASE SUBSCRIPT "c" DENOTES SWITCH DESIGNATION "c". OTHER SUBSCRIPT DENOTES:

K = KEYED SWITCH

3 = THREE WAY

4 = FOUR WAY

3K = THREE WAY KEYED SWITCH

4K = FOUR WAY KEYED SWITCH

D = DIMMER (NO SUBSCRIPT- 1200W, SUBSCRIPT 1 - 600W)

M = MOTOR RATED SWITCH

OS = OCCUPANCY SENSOR/WALL SWITCH

T = ADJUSTABLE TIMER SWITCH

La = LOW VOLTAGE SWITCH, LETTER DENOTES ZONE OF CONTROL

LP = LOW VOLTAGE SWITCH FOR PROJECTION SCREEN

F = CEILING FAN SPEED CONTROL

SC = LOW VOLTAGE MULTI-SCENE SWITCH.

2L = 2 BUTTON LOW VOLTAGE SWITCH (I.E. SWITCH LEGS "a" AND "b")

RT = REMOTE EMERGENCY LIGHT TEST SWITCH

MGB

SGB

PBB/SBB

FM

FLOOR MOUNTED MULTI-SERVICE FLUSH FLOOR BOX - 4- 125V, 20A, 1PH, 3-WIRE

NEMA 5-20R RECEPTACLES PLUS 16 RJ-45 CAT 6 COMMUNICATIONS JACKS UON.

SUBSCRIPTS AS DEFINED ABOVE.

SM - SURFACE MOUNTED

CM - CEILING MOUNTED

MAIN GROUND BAR

SECONDARY GROUND BAR

WALL MOUNTED UON DUPLEX RECEPTACLE - 125V, 20A, 1PH, 3-WIRE NEMA

5-20R MOUNTED 6" ABOVE COUNTERTOP OR BACKSPLASH OR 42" AFF TO CENTER

OF RECEPTACLE UON. SUBSCRIPTS AS DEFINED ABOVE.

WALL MOUNTED UON SIMPLEX RECEPTACLE - 125V, 20A, 1PH, 3-WIRE

NEMA 5-20R MOUNTED 18" AFF TO CENTER OF RECEPTACLE

UON. SUBSCRIPTS AS DEFINED ABOVE.

WALL MOUNTED UON DOUBLE DUPLEX RECEPTACLE - TWO 125V, 20A, 1PH,

3-WIRE NEMA 5-20R UNDER COMMON COVER PLATE MOUNTED 18" AFF

TO CENTER OF RECEPTACLE UON. SUBSCRIPTS AS DEFINED ABOVE.

WALL MOUNTED SPECIAL RECEPTACLE 18" AFF TO CENTER OF RECEPTACLE - UON

COORDINATE NEMA CONFIGURATION WITH EQUIPMENT SUPPLIER.

TELECOMM GROUND BAR

LIGHTING CONTROL ZONE

LIGHTING CONTROL RELAY (POWER PACK).

R

ZXXX

D DAYLIGHT DIMMING CONTROL RELAY.

PBB PRIMARY BONDING BUSBAR

CEILING MOUNTED EMERGENCY LIGHT FIXTURE

WALL MOUNTED EMERGENCY LIGHT FIXTURE

WALL MOUNTED COMBO EXIT SIGNS WITH EMERGENCY FIXTURE .

Eu EXISTING UNDERGROUND ELECTRIC CABLE(S) TO BE REMOVED

EMERGENCY RELAY.

LC

CORD DROP RECEPTACLE

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

9/27/2022 10:23:43 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

E-001

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

E L Y

E L Y

M C

K F

E L E

C T R

IC

A

L L

E G

E N

D

A B

B R

IE

V

IA

T

IO

N S

A N

D G

E N

E R

A L

N O

T E

S

SM

G

M

WP

VFD

SURFACE MOUNTED PANELBOARD

RECESSED MOUNTED PANELBOARD

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

a

MOTOR RATED TOGGLE SWITCH

MOTOR CONNECTION

VARIABLE FREQUENCY DRIVE

PANELBOARD DESIGNATION KEY:

CONDUIT OR CABLE CONCEALED IN WALLS OR ABOVE CEILINGS

CONDUIT OR CABLE EXPOSED

CONDUIT OR CABLE UNDER RAISED FLOOR

LOW VOLTAGE CABLE

CONDUIT OR CABLE TURNING UP

CONDUIT OR CABLE TURNING DOWN

CONDUIT OR CABLE CHANGE IN ELEVATION

CONDUIT CAPPED

GROUNDING BUS.

SWITCH LEG CONNECTED TO SWITCH "a".

#10, 3/4"

COMBINATION MOTOR STARTER/FUSED DISCONNECT SWITCH:

600V, 3-POLE, 30A SWITCH, 30A FUSES, SIZE 1 STARTER, IN NEMA 1 ENCLOSURE,

MOUNTED 60" AFF UON.

FUSIBLE DISCONNECT SWITCH:

600V, 3-POLE, 30A SWITCH, 30A FUSES, IN NEMA 1 ENCLOSURE, MOUNTED 60" AFF

UON.

SURFACE MOUNTED DISTRIBUTION PANEL

NOTE:

CONDUIT OR CABLE IN SLAB OR UNDERGROUND

FEEDER CALLOUT

NON-FUSIBLE DISCONNECT SWITCH:

600V, 30A, 3-POLE, IN NEMA 1 ENCLOSURE, MOUNTED 60" AFF UON.

ENCLOSED CIRCUIT BREAKER:

600V, 100AF/100AT, 3-POLE IN NEMA 1 ENCLOSURE, MOUNTED 60" AFF UON.

ENCLOSED MOTOR STARTER. SIZE 1 STARTER IN NEMA 1 ENCLOSURE UON.

BRANCH CIRCUIT WIRING. #10 INDICATES AWG WIRE SIZE, AND 3/4" CONDUIT

SIZE. ALL BRANCH CIRCUIT WIRING SHALL INCLUDE A MINIMUM #12 AWG GROUND WIRE (NOT

SHOWN) UON. NO WIRING INFORMATION DENOTES 2- #12 AWG + #12 AWG GROUND IN 3/4" CONDUIT

HOMERUN TO PANELBOARD. RP1-2,4 INDICATES ORIGINATING PANEL AND

CIRCUIT NUMBERS. IF COLON IS USED BETWEEN CIRCUIT NUMBERS THEN

A MULTIPOLE CIRCUIT BKR IS DENOTED. RP1-2:4 DENOTES ORIGINATING PANEL

AND CIRCUIT NUMBERS WITH A 2-POLE BKR AT THE PANEL.

WEATHER PROTECTED TOGGLE SWITCH

N1 = NEMA1, N3R = NEMA 3R, N3RSS = NEMA 3R STAINLESS STEEL, N4X = NEMA 4X,

N12 = NEMA 12

GROUNDING SYMBOLS

SWITCH AND CONTROL SYMBOLS

DISTRIBUTION EQUIPMENT SYMBOLS

WIRING SYMBOLS

PE

PANEL NUMBER

BUILDING DESIGNATOR: A- ADMINISTRATION, E-EDUCATION, B-BILLETING

PANEL DESIGNATOR: P-POWER PANEL, L-LIGHTING PANEL, R- RECEPTACLE PANEL,

T-TELECOM PANEL, DP-DISTRIBUTION PANEL, MDP- MAIN DISTRIBUTION PANEL,

E-EMERGENCY PANEL

GENERAL NOTES

FLOOR MOUNTED SWITCHBOARD

S

PERFORM ALL WORK IN ACCORDANCE WITH THE 2017 EDITION OF THE NATIONAL ELECTRICAL CODE AND ALL OTHER APPLICABLE BUILDING CODES AS INTERPRETED BY THE LOCAL

AUTHORITY HAVING JURISDICTION.

IT IS THE INTENT OF THE THESE DRAWINGS TO CALL FOR FINISHED WORK, TESTED AND READY FOR OPERATION. THE WORD PROVIDE MEANS "FURNISH AND INSTALL COMPLETE AND READY FOR USE". COORDINATE EXACT LOCATION OF DEVICES AND ELECTRICAL SERVICE REQUIREMENTS WITH EQUIPMENT VENDOR PRIOR TO INSTALLATION.

CIRCUIT NUMBERS SHOWN ON THE DRAWINGS ARE FOR REFERENCE ONLY. IT WILL BE THE CONTRACTOR'S RESPONSIBILITY TO BALANCE LOADS AMONG PHASES IN

PANELBOARDS TO WITHIN 10% OF EACH OTHER.

PROVIDE MINIMUM #12 AWG WIRE SIZE IN 3/4" CONDUIT FOR ALL BRANCH CIRCUITRY UON.

ALL ELECTRICAL EQUIPMENT SHALL BE LISTED AND LABELED FOR THE QUALIFIED USE.

ALL MOUNTING HEIGHTS INDICATED ARE MEASURED FROM FINISHED FLOOR TO THE CENTER OF DEVICE UNLESS OTHERWISE SHOWN OR NOTED.

SOME LEGEND SYMBOLS MIGHT NOT BE USED. SEE FLOOR PLANS FOR APPLICABLE DEVICES.

THE ELECTRICAL DRAWINGS ARE DIAGRAMMATICAL IN NATURE AND INDICATE THE GENERAL LOCATION OF OUTLETS. EQUIPMENT AND THE CIRCUIT ARRANGEMENT OF THE REQUIRED WIRING. ALTHOUGH THE DRAWINGS DO NOT NECESSARILY INDICATE THE ACTUAL ROUTES OF CONDUITS, WHERE INDICATED, THEY SHALL BE FOLLOWED AS CLOSELY AS PROPER COORDINATION WITH THE WORK OF OTHER TRADES AND SPACE WILL PERMIT. THE DRAWINGS ARE NOT INTENDED TO BE SCALED AND THE CONTRACTOR SHALL

REFER TO THE COMPLETE SET OF CONSTRUCTION DRAWINGS FOR COORDINATION.

ALL LIGHTING AND RECEPTACLE BRANCH CIRCUITS SHALL HAVE A SEPARATE NEUTRAL PER CIRCUIT.

PROVIDE FIRE STOPPING FOR ALL ELECTRICAL PENETRATIONS OF RACEWAYS AND BOXES THROUGH FIRE RATED CEILINGS, FLOORS, WALLS, AND PARTITIONS. REFER TO THE SPECIFICATIONS FOR ADDITIONAL INFORMATION ON FIRE STOP SYSTEMS. REFER TO LIFE SAFETY PLANS FOR LOCATIONS AND FIRE RESISTANCE RATINGS.

120 VOLT BRANCH CIRCUITS, WHERE THE LENGTH OF CIRCUIT CONDUCTORS COMPLETE FROM CIRCUIT BREAKER IN SOURCE PANEL TO ANY DEVICE ON THE CIRCUIT IS 0-100 FEET FROM THE PANEL, ARE TO HAVE #12 MINIMUM BRANCH CIRCUIT WIRING THROUGHOUT CIRCUIT. (CONDUIT SIZE PER NEC).

120 VOLT BRANCH CIRCUITS, WHERE THE LENGTH OF CIRCUIT CONDUCTORS COMPLETE FROM CIRCUIT BREAKER IN SOURCE PANEL TO ANY DEVICE ON THE CIRCUIT IS 101-175 FEET FROM THE PANEL, ARE TO HAVE #10 MINIMUM BRANCH CIRCUIT WIRING HOMERUN (3/4"C.) FROM PANEL CIRCUIT BREAKER TO FIRST DEVICE AND #12 BRANCH CIRCUIT WIRING THROUGHOUT THE REMAINDER OF THE CIRCUIT. (CONDUIT SIZE PER SPECIFICATION AND NEC). FIRST 75 FEET OF COMBINED HOMERUN AND BRANCH CIRCUIT TO BE MINIMUM #10

WIRE. (3/4"C).

120 VOLT BRANCH CIRCUITS, WHERE THE LENGTH OF CIRCUIT CONDUCTORS COMPLETE FROM CIRCUIT BREAKER IN SOURCE PANEL TO ANY DEVICE ON THE CIRCUIT IS 176-225 FEET FROM THE PANEL, ARE TO HAVE #10 MINIMUM BRANCH CIRCUIT WIRING HOMERUN (3/4"C.) FROM PANEL CIRCUIT BREAKER TO FIRST DEVICE AND #10 BRANCH CIRCUIT WIRING

THROUGHOUT THE REMAINDER OF THE CIRCUIT (3/4"C.)

120 VOLT BRANCH CIRCUITS, WHERE THE LENGTH OF CIRCUIT CONDUCTORS COMPLETE FROM CIRCUIT BREAKER IN SOURCE PANEL TO ANY DEVICE ON THE CIRCUIT IS 226 FEET OR MORE FROM THE PANEL, ARE TO HAVE #8 MINIMUM BRANCH CIRCUIT WIRING HOMERUN (1"C.) FROM PANEL CIRCUIT BREAKER TO FIRST DEVICE AND #10 BRANCH CIRCUIT WIRING THROUGHOUT THE REMAINDER OF THE CIRCUIT (3/4"C.). FIRST 125 FEET OF COMBINED HOMERUN AND BRANCH CIRCUIT TO BE MINIMUM #8 WIRE (1"C.)

FURNISH AND INSTALL U.L. CLASSIFIED WALL OPENING MATERIAL WHERE REQUIRED TO MEET FIRE STOPPING REQUIREMENTS. TYPICAL FOR ALL ELECTRICAL BOXES WITHIN FIRE

RATED WALLS. REFER TO LIFE SAFETY PLANS FOR FIRE RATED WALL LOCATIONS.

G

G

Gx

G

G

GROUND ROD WITH WELDED CONNECTION

WELDED GROUND CONNECTION

BOLTED GROUND CONNECTION

GROUND ROD 3/4" X 20' (UON)

GROUNDING CONDUCTOR - BURIED

GROUNDING CONDUCTOR - EXPOSED

TEST WELL

G

G

G

GROUND COUNTERPOISE

GROUND COIL

STATIC GROUND CONNECTION

AIR TERMINAL

R

THRU-ROOF PENETRATION

W

THRU-WALL PENETRATION

M

G

GFP

SPD

TRANSFORMER

DRAW OUT CIRCUIT BREAKER

PANELBOARD

T112

TRANSFER SWITCH

MOLDED CASE CIRCUIT BREAKER

LUG CONNECTION

FUSED DISCONNECT SWITCH

SURGE PROTECTION

ELECTRIC METER

GROUND FAULT PROTECTION

CURRENT TRANSFORMER

GENERATOR

TRANSFORMER (T112 = 112.5kVA, NO LETTER: GENERAL DUTY, K: K-13 RATED, H: HARMONIC

CANCELING)

CIRCUIT IDENTIFIER TAG; "M" INDICATES MAIN DEVICE, NUMERAL

INDICATES CIRCUIT NUMBER

SINGLE LINE DIAGRAM SYMBOLS

ST

ST

K

POLE MOUNTED FUSED CUTOUT

CABLE TERMINATION WITH STRESS RELIEF

LOAD BREAK DRAWOUT FUSE

SHUNT TRIP PUSH BUTTON

SHUNT TRIP

LIGHTNING ARRESTOR

KIRK-KEY INTERLOCK

AUTOMATIC TRANSFER SWITCH

DUCT BANK

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

9/27/2022 10:23:44 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

E-002

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

E L Y

E L Y

M C

K F

E L E

C T R

IC

A

L L

E G

E N

D

A B

B R

IE

V

IA

T

IO

N S

A N

D G

E N

E R

A L

N O

T

ESu

ESu

ESu

ESu

Eu

Eu

Eu

Eu

Eu

Eu

D

C

B

A

CC

BB

AA

2.4 3.62 3 4 5 61

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4 3.6

B'

1. REFER TO ELECTRICAL GENERAL NOTES ON SHEET E-002.

2. ELECTRICAL CONTRACTOR SHALL COORDINATE ELECTRICAL

DEMOLITION WITH DEMOLITION WORK OF OTHER TRADES.

3. ELECTRICAL CONTRACTOR SHALL FIELD VERIFY ALL REQUIRED

ELECTRICAL DEMOLITION PRIOR TO COMMENCING WORK.

4. DISPOSAL OF FLUORESCENT AND HID LAMPS AND BALLASTS

SHALL BE CONSIDERED HAZARDOUS WASTE. COORDINATE

PROPER REMOVAL AND DISPOSAL WITH THE FLANG

ENVIRONMENTAL GROUP.

5. REMOVE ALL EXISTING INTERIOR AND EXTERIOR LIGHTING

FIXTURES, SWITCHES, CONTROLS ETC AND ALL ASSOCIATED

ELECTRICAL BACK TO POWER SOURCE. REFER TO LIGHTING

PLANS FOR NEW REQUIREMENTS.

6. REMOVE ALL EXISTING INTERIOR AND EXTERIOR

RECEPTACLES, JUNCTION BOXES, WIRE, AND CONDUIT BACK

TO POWER SOURCE. REFER TO POWER PLANS FOR NEW

REQUIREMENTS.

7. REMOVE ALL EXISTING PANEL BOARDS, ALL JUNCTION BOXES,

ALL WIRE AND EXPOSED CONDUIT BACK TO POWER SOURCE.

REMOVE ANY CONCRETE PANEL CURB TO FINISHED FLOOR.

CUT ALL UNDERFLOOR CONDUITS TO 2” BELOW FLOOR SLAB,

EXCEPT WHERE IDENTIFIED FOR RE-USE. COORDINATE

PAINTING, PATCHING AND FLOOR REPAIRS WITH

ARCHITECTURAL DRAWINGS AND SPECIFICATIONS.

8. DISCONNECT AND REMOVE ELECTRICAL CONNECTIONS TO ALL

THE EXISTING MECHANICAL AND PLUMBING EQUIPMENT,

INCLUDING DISCONNECT SWITCH, STARTERS, WIRE, AND

CONDUIT BACK TO POWER SOURCE. COORDINATE WITH

MECHANICAL PRIOR TO DISCONNECTING ELECTRICAL SERVICE

TO MECHANICAL EQUIPMENT.

9. REMOVE EXISTING FEEDERS.

DEMOLITION NOTES

DEMOLITION LEGEND

AREA/ITEMS TO BE DEMOLISHED. REFER

TO DEMOLITION NOTES.

KEYNOTES

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 10:23:55 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

ED101

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

E L Y

E L Y

M C

K F

E L E

C T R

IC

A

L D

E M

O L

IT

IO

N

P L A

N

1/8" = 1'-0"D1

ELECTRICAL DEMOLITION PLAN

1 EXISTING 30KW/37.5KVA, 208/120V,3 PHASE DIESEL

GENERATOR.

2 EXISTING PAD MOUNTED TRANSFORMER, 300KVA,

24.5KV-208/120V, 3 PHASE.

3 DISCONNECT AND REMOVE EXISTING

UNDERGROUND FEEDERS BETWEEN 300KVA

TRANSFORMER AND MDP LOCATED IN ELECTRICAL

ROOM. FIELD VERIFY EXISTING CONDITIONS PRIOR

TO STARTING WORK.

4 DISCONNECT AND REMOVE EXISTING

UNDERGROUND FEEDERS BETWEEN 100A,208V/3

PHASE GENERATOR'S DISCONNECT SWITCH AND

MTS LOCATED IN MECHANICAL ROOM. FIELD

VERIFY EXISTING CONDITIONS PRIOR TO STARTING

WORK.

WH

R E

F

C P1

/0 9/

CA

L

E:

0, S C

AL

E

,0

P R

I

NT

E R

P O

W E

R C

O

RD

I N

LE

T

9, (1

4, 358,1 (14,1")

136,2 (5,36")

-60

ELE

CTRO

NIC

VIT

AL S

IG

N

S M O

BIL

E ST

AND

A

.V.

/1/

3 SC

ALE

5:1

EQ

S

PACE

22.0000

3.2428

7.9990

.1325

2.8200

C P1

/0 9/

L

E:

0, S C

AL

E

,0

P R

I

NT

E R

P O

W E

R C

O

RD

I N

LE

T

358,1 (14,1")

136,2 (5,36")

-60

ELE

CTRO

NIC

VIT

AL S

IG

N

S M O

BIL

E ST

AND

A

.V.

/1/

3 SC

ALE

5:1

EQ

S

PACE

22.0000

3.2428

7.9990

.1325

2.8200

C P1

/0 9/

L

E:

0, S C

AL

E

,0

P R

I

NT

E R

P O

W E

R C

O

RD

I N

LE

T

358,1 (14,1")

136,2 (5,36")

-60

ELE

CTRO

NIC

VIT

AL S

IG

N

S M O

BIL

E ST

AND

A

.V.

/1/

3 SC

ALE

5:1

EQ

S

PACE

22.0000

3.2428

7.9990

.1325

2.8200

C P1

/0 9/

L

E:

0, S C

AL

E

,0

P R

I

NT

E R

P O

W E

R C

O

RD

I N

LE

T

358,1 (14,1")

136,2 (5,36")

-60

ELE

CTRO

NIC

VIT

AL S

IG

N

S M O

BIL

E ST

AND

A

.V.

/1/

3 SC

ALE

5:1

EQ

S

PACE

22.0000

3.2428

7.9990

.1325

2.8200

T

ESu

ESu

ESu ESu

ESu ESu

ESu

E

E

E

E

E

E

E

E

E E

E E

E

EXISTING

TRANSFORMER,

300kVA

4W800S

NOT IN CONTRACT

NOT IN CONTRACT

4W100

4W100

PB

PB

TO "MTS"

TO "MDP"

EXISITING

GENERATOR,

30kW/37.5kVA

TYP

KEYNOTES

A. REFER TO SHEET E-001 AND E-002 FOR LEGEND,

ABBREVIATIONS, AND NOTES.

B. REFER TO BUILDING LIGHTING PLANS FOR BUILDING MOUNTED

FIXTURES AND CANOPY PLANS.

C. REFER TO SHEET E-701 LIGHTING FIXTURE SCHEDULE.

D. REFER TO E-500 SERIES DRAWING FOR SUPPLEMENTAL

DETAILS.

E. REFER TO ELECTRICAL SINGLE LINES ON SHEETS E-601 AND

E-602 FOR ADDITIONAL INFORMATION.

F. REFER TO SHEET E-702 FOR FEEDER SCHEDULE.

G. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND

INDICATE THE GENERAL EXTENT OF THE WORK. ALL PULL

BOXES, JUNCTION BOXES AND INCIDENTAL MATERIALS AND

LABOR FOR COMPLETELY FULLY FUNCTIONAL SYSTEMS TO BE

PROVIDED BY THE CONTRACTOR.

H. EQUIP ALL UNDERGROUND CONDUITS, ACTIVE AND EMPTY WITH

DETECTABLE WARNING TAPE.

I. REFER TO SITE/ CIVIL UTILITY LAYOUT PLAN FOR LOCATIONS OF

ELECTRICAL AND TELECOMMUNITION MANHOLES AND

COORDINATION WITH OTHER UTILITIES.

J. REFER TO SITE/CIVIL DEMOLITION PLAN FOR DEMOLITION OF

EXISTING SECONDARY CONDUCTORS FEEDING BUILDING 1002B.

GENERAL NOTES

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 10:24:16 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

ES101

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

K F

K F

M C

K F

E L E

C T R

IC

A

L S

IT

E

P L A

N

1" = 20'-0"D1

ELECTRICAL SITE PLAN

1 EXISTING PAD MOUNTED TRANSFORMER, 300KVA,

24.5KV-208/120V, 3 PHASE.

2 EXISTING 30KW/37.5KVA, 208/120V,3 PHASE DIESEL

GENERATOR.

3 PROVIDE NEW PRE-CAST, HS-20 TRAFFIC RATED

RATED PULL BOX. REFER TO DETAIL B3/E-501 FOR

TYPICAL PRE-CAST PULL BOX DETAIL.

4 CONDUITS ROUTED UNDERGROUND TO THE

EXTERIOR WALL. REFER TO TYPICAL DUCT BANK

DETAIL B5/E-501 FOR UNDERGROUND ROUTING OF

THE CONDUITS.

5 CONDUITS ROUTED UNDERGROUND TO THE

BUILDING EXTERIOR WALL, TURN UP SURFACE

EXPOSED ON THE WALL IN RGC CONDUIT,THEN

RUN THROUGH EXTERIOR WALL TO THE

ELECTRICAL ROOM AND CONNECT TO MDP.

6 CONDUITS ROUTED UNDERGROUND TO THE

BUILDING EXTERIOR WALL, TURN UP SURFACE

EXPOSED ON THE WALL IN RGC CONDUIT,THEN

RUN THROUGH EXTERIOR WALL TO THE

ELECTRICAL ROOM AND CONNECT TO MTS.

LVLV

LV

sc v s v s vs vs vs v s o s o s vs v s v s v s v s vs vs vs vs vs vs v s v s v s v s vs v s vs vs

R LCLCRRR

R R

R

R

R

R

R

LC

LC

LC

R

R

R

LC

R

R

R

R o s

LV LV

v s

L V

L V

LV

L V os o s

OS

OS

VS VS

VS VS

VS

VS VS VS

VS VS VS

OSOSOSOS

OS

OS

OS

OS

OS

OS

OS

OSOSOSOSOS

VS

LV

OS

LV LV

VS VS

VS

VS

VSVS

VS

VS

VS

LV

VS

VS

J

LC

LC

R

LCR

RLC

LC

LC

RLC

LC

LC

LC

R

LC

LC

R

LC

LC

LC

LC

LC R

LC

LC LC LC LC

R R

LC

LC

LC

LC

LC

R o s

R

LC LC LC

LC

LC LC

LC

LC

LC

LC R

o s

J

L V

LV

VS

LC

L V os

LC

LC

LC

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4

3.6

B'

OPEN OFFICE

EXAM RM.

OFFICE

COMM.

ELECT.

F. SHOWER

J. CLO.

STORAGE

CLASSROOM

CONFERENCE

OPEN OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

FA CLO.

OFFICE

WAITING

OPEN OFFICE

OFFICE

OFFICE

OFFICE

CORR.

CORRIDOR

BREAK RM.

SIM RM.

OFFICE

STORAGE

F. TOILET

M. SHOWER

CORR.

PHARMACY

M. TOILET

141CLINICAL LAB

142OPEN OFFFICE

LAB STOR BIO

ENV

EQUIP.

OFFICE

114CORR.

CORR.

DENTAL EXAM.

DENTAL EXAM.

OPEN OFFICE

OPEN OFFICE

CORRIDOR

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

CORR.

MECH.

OFFICE

CORRIDOR

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STO.

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

A4L A4L A4L A4LE

A4LE A4L A4L A4L

A4L A4L A4LE A4L A4L

A4L

A4LE

A4LA4L

A4M A4M

A4LE A4L A4L A4L

A4L

A4L

A4LE

A4L

A4L

A4L

A4L

A4LE

A4L

A4LE

A4L

A4L

A4L

A4LE

A4L A4L

A4L

A4LE

A4L

A4LE

A4L

A4L A4L

A4L

A4LE

A4M A4ME

A4M

A4ME

A4ME

A4L A4L

A4L A4LE

A4ME A4M

A4L

A4L

A4LE

A4L

A4LE

A4LE

A4LEA4LA4LA4LEA4LA4LA4LE

A4L

A4L

A4M

A4ME

A4M

A4M

A4ME

A4M

A4M

A4ME

A4M

A4M

A4ME

A4M

A4L

A4LE

A4L A4L

A4LE

A4L

A4LE

A4L A4L

A4L A4L

A4L A4L

A4L A4L

A4L

A4LE

A4L A4L

A4L

A4L A4L

A4LE A4L

A4L A4L

F4E

F4

F4E F4

C3C3E

C3C3E

C3E

C3C3E

C3E

C3

A4ME A4M

A4M A4M

A4M A4ME A4M

A4L A4L A4L

A4LA4LE

F2

A4LE A4L

A4L A4L A4L A4LE A4L

A4L A4L A4L A4L A4L A4L

A4M

A4M

A4L

A4L

A4L

A4M

A4M A4L A4L

A4L

A4L

F2

LP: 1

LP: 1

LP: 1

LP: 2

LP: 2

LP: 2

LP: 2

LP: 3

LP: 3

LP: 4

LP: 4

LP: 4

LP: 4

LP: 4

LP: 4

LP: 4

LP: 5

LP: 5

LP: 5

LP: 5

LP: 5

LP: 5

LP: 6

LP: 6

LP: 6

LP: 6

LP: 6

LP: 6

LP: 6

LP: 7LP: 7LP: 7LP: 7LP: 7LP: 7

LP: 8

LP: 8

LP: 8

LP: 8

LP: 8

LP: 8 LP: 8

LP: 1

LP: 1

LP: 1LP: 1

LP: 6

F2

LP: 5

LP: 8

W2

W2

3 TYP

LP: 9

EX

EX

EX

EX

EX

EX

EX

A4L

A4L

A4L

A4L

A4L

A4L

F2

LP: 5

EXISTING CANOPY

LIGHTING TO REMAIN.

TYP

TYP5

EXISTING CANOPY

LIGHTING TO REMAIN.

a b c b c bcbcb c a a a a a a,b b a b baba a b a b a a a b b a a a,b a b a,b a,b abab b a a,b a b b a b

LP: 9

a,b,c a a,b a b b a

W2

F4E a,b

C3E

LP: 5

5 5TYP

WP

a b a b b a a,b

D D

D

F4

OFFICE

OPEN OFFICE

EX

EX

NL

NL

NL

NL

NLNL

NL

NL

NL

NL

NL

1. REFER TO SHEET E-001 AND E-002 FOR LEGEND,

ABBREVIATIONS, AND NOTES.

2. REFER TO E-700 SERIES DRAWINGS FOR PANELBOARD

SCHEDULES.

3. REFER TO SHEET E-701 LIGHTING FIXTURE SCHEDULE.

4. REFER TO E-500 SERIES DRAWING FOR SUPPLEMENTAL

DETAILS.

5. THESE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND

INDICATE THE GENERAL EXTENT OFTEN WORK. THE

CONTRACTOR SHALL PROVIDE ALL PULL BOXES, JUNCTION

BOXES AND INCIDENTAL MATERIALS AND LABOR FOR

COMPLETELY FULLY FUNCTIONAL SYSTEMS.

6. ALL EXIT SIGNS SHALL BE CIRCUITED UNSWITCHED TO

CIRCUITS AS INDICATED.

7. WIRE EMERGENCY LIGHTS TO SWITCH OFF WITH NORMAL

LIGHTING CONTROLS, UNLESS OTHERWISE NOTED. PROVIDE

AN ADDITIONAL UNSWITCHED HOT WIRE TO THE EMERGENCY

DRIVER.

8. PROVIDE EXPANSION FITTINGS/COUPLINGS AT ALL ABOVE

CEILING CONDUITS RUNS AT EXPANSION JOINTS. REFER TO

SPECIFICATIONS.

9. EXTERIOR LIGHT CIRCUITS SHALL BE CONTROLLED VIA

ASTRONOMICAL TIMER. REFER DETAIL D5/E-502 AND PANEL

SCHEDULE FOR ADDITIONAL INFORMATION.

10. ALL EMERGENCY LIGHTS LABELED 'NL' ARE NIGHT LIGHT

FIXTURES AND SHALL BE UNSWITCHED.

GENERAL NOTES

KEYNOTES

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 10:24:01 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

EL101

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

K F

K F

M C

K F

L

IG

H

IT

N G

P L A

N

1/8" = 1'-0"D1

LIGHTING PLAN

1 PROVIDE AND INSTALL EMERGENCY LIGHTING

INTERFACE CONTROLLER FOR EACH ROOM

LIGHTING CONTROLLER TO ACTIVATE SWITCHED

EMERGENCY LIGHTS UPON FIRE ALARM

ACTIVATION. REFER TO TYPICAL DETAIL B4 ON

SHEET E-502 FOR ADDITIONAL INFORMATION.

2 MOUNT FIXTURE AT 9'-0" AFG TO BOTTOM OF

FIXTURE.

3 MOUNT FIXTURE AT 10'-0" AFG TO BOTTOM OF

FIXTURE.

4 CANOPY LIGHTING IS EXISTING TO REMAIN.

RECONNECT EXISTING LIGHTING ON THE

CANOPY TO PANEL LP-9.

5 TYPICAL LIGHT CONTROL RELAY OR POWER

PACK. COORDINATE EXACT NUMBER OF RELAYS

WITH SELECTED LIGHTING CONTROLS

MANUFACTURER. REFER TO TYPICAL RELAY

LIGHTING CONTROL CONFIGURATIONS ON E-501

AND E-502.

6 COORDINATE FIXTURE FINAL MOUNTING

HEIGHTS AND LOCATIONS WITH MECHANICAL

EQUIPMENT.

7 CIRCUIT EXTERIOR LIGHTING CIRCUIT VIA

TIMECLOCK LOCATED IN MAIN ELECTRICAL ROOM

E135. REFER TO DETAIL D5/E-502 FOR

ADDITIONAL INFORMATION.

D W

R E

F

CP

/0

C

A

LE

:0 ,5

S C

A

LE

1, P R

IN

TE

R P

O W

E R

C O

R D

I N

LE

T

9, ,9

4"

358,1 (14,1")

136,2 (5,36")

L

E C

T R

O N

I

V

TA

G N

M O

B I

A

N D

A

1/

AL

E

Q

P A

C E

2.

.2

.9

.8

CP

A

LE

:0 ,5

S C

A

LE

1, P R

IN

TE

R P

O W

E R

C O

R D

I N

LE

T

9, ,9

4"

358,1 (14,1")

136,2 (5,36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

CP1

2013/ 09/0

S

C A

LE

:0

,500

S C

A

LE

1,0

P R

IN

TE

R P

O W

E R

C O

R D

IN

LE

T

379, (14,94")

358 , 1 (14, 1")

136 , 2 (5, 36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

CP1

2013/ 09/0

S

C A

LE

:0

,500

S C

A

LE

1,0

P R

IN

TE

R P

O W

E R

C O

R D

IN

LE

T

379, (14,94")

358 , 1 (14, 1")

136 , 2 (5, 36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

1 5

A

C E

2.

.2

.9

.8

WH

D W

R E

F

CP

A

LE

:0 ,5

S C

A

LE

1, P R

IN

TE

R P

O W

E R

C O

R D

I N

LE

T

9, ,9

4"

358,1 (14,1")

136,2 (5,36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

CP

A

LE

:0 ,5

S C

A

LE

1, P R

IN

TE

R P

O W

E R

C O

R D

I N

LE

T

9, ,9

4"

358,1 (14,1")

136,2 (5,36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

CP1

2013/ 09/0

S

C A

LE

:0

,500

S C

A

LE

1,0

P R

IN

TE

R P

O W

E R

C O

R D

IN

LE

T

379, (14,94")

358 , 1 (14, 1")

136 , 2 (5, 36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

CP1

2013/ 09/0

S

C A

LE

:0

,500

S C

A

LE

1,0

P R

IN

TE

R P

O W

E R

C O

R D

IN

LE

T

379, (14,94")

358 , 1 (14, 1")

136 , 2 (5, 36")

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

S

J

J

J

J JJ

S

J J

J J

S

J J

J

S

S S

SS

S

J

J

J

J

J

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4

3.6

B'

CLASSROOM

CORRIDOR

CONFERENCE

OPEN OFFICE

152OPEN OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

CORR.

101FA CLO.

OFFICE

WAITING

OPEN OFFICE

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

120 CORR.

124 MECH.

CORRIDOR

ELECT.

COMM.

F. SHOWER

J. CLO.

M. SHOWER

STORAGE

F. TOILET

OFFICE

EXAM RM.

OPEN OFFICE

DENTAL EXAM.

DENTAL EXAM.

OPEN OFFICE

CORR.

OFFICE

EQUIP.

LAB STOR BIO

ENV

OPEN OFFFICE

CLINICAL LAB

PHARMACY

M. TOILET

CORR.

OPEN OFFICE

OFFICE

OFFICE

159 OFFICE

CORR.

BREAK RM.

SIM RM.

OFFICE

STORAGE

OFFICE

CORRIDOR

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STO.

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

E-401

D1

E-401

D6

G

G

G

G

G

G

G

G

TVTV

TV

G G G

G

G

G

G

WPG

CU-1

SSCU-2SSCU-1

ETR

SSAC

FM

FM

FMFM

EP: 2 EP: 17

EP:2

EP:17

EP:2EP:17

EP:2

EP:17 RP2: 6

RP2:7

RP2:7

EP:17

RP2:29

EP: 17

EP: 2

RP2: 6

EP:2

EP:17

EP:17

EP:2

RP2:6

RP2:7RP2:7

RP2:5

RP2:3

RP2:1 RP2:5

RP2:3

RP2:1

RP2: 1

RP2: 3

RP2: 5

RP2:1

RP2:3

RP2:5

RP2: 7

RP2:31

RP2:7

RP2:10

RP2:10

RP2:10

RP2: 9

RP2: 10

RP2:9

RP2:9

RP2:9

RP2:8

RP2:8

RP2:8

RP2: 8

RP2:11

RP2:11

RP2:13

RP2:13

RP2:12

RP2:12

RP2:12 RP2:14

RP2:14

RP2:14

RP2:15

RP2:15

RP2:15

RP2: 13

RP2: 11

RP2: 12

RP2: 14 RP2: 15

RP2: 16

1 2TYP OF 3

M

G

RP2: 19

RP2: 20

RP2:24

RP2: 24

RP2: 17

RP2: 18

RP2:24

RP2: 22

RP2: 21

RP2: 23

RP2: 25

RP2:25

RP2:25

RP2: 26RP2:26

RP2:26

RP2:26

RP1:25

RP1:25

RP1:32

RP1:25

RP1:8RP1:37RP1:8

RP1:37

RP2: 7

RP1:27

RP1:27

RP1:27

RP1: 27

RP1:7

RP1:6

RP1:6

RP2: 27

RP1:11

RP1:11

RP1:11

RP1:34

RP1:11

RP1:11

RP1: 37

RP1: 8

RP1:2

RP1:2

RP1:2

RP1: 2

RP1: 6

EP:15

EP:15

EP: 15

EP: 14

EP:13

EP:13

EP: 13

RP1:7

RP1:7

RP1: 7

RP1:7

RP1:7

RP1:13

RP1:39

RP1:13

EP:21

RP1: 35

RP1:20

RP1:20

RP1:20

RP1:35

EP:21

RP1: 20

RP1:10

RP1:36 EP:12

EP:9

EP: 8

EP:11

EP: 10

EP:11

EP:9

EP:7

EP:7

EP: 8

EP:5

EP:5

EP:6

EP:6

EP: 5

EP: 6

EP: 4

EP: 4

RP1: 16

RP1: 24

RP1:24

RP1:24 RP1:24

RP1:24

RP1:23

RP1:18

RP1:18

RP1: 18

RP1:5

RP1:5 RP1: 5

RP1:19

RP1:19

RP1:21

RP1:21 RP1: 21

RP1: 19

RP1: 22

RP1:22

RP1:22

RP1:22

7 7

EP: 10

RP2: 27

RP2: 27

EP: 18 EP: 19

EP: 16

RP1:23

RP1: 23

RP1: 23

FA: 5

FA: 3FA: 1

RP2:25

M

FM

FM

RP2:6

RP2: 29

RP1: 29,31,33

RP1: 9

RP1: 9

RP1: 9RP1: 9

M

RP1: 1

G

RP2: 28

RP2: 27 RP1: 4

RP1: 4

12 12

M1: 28,30,32

M

RP1: 15,17

FA

SPD

TR: 11,13

M1: 34,36

M M

TR: 10

TO SSCU-1,

EXTERIOR

M

M

TO SSCU-2,

EXTERIOR

M1: 39

SSAC-2

EUH-1

M M1: 33,35,37

EP: 1

RP2:2RP2:2

RP2:2

RP2: 2

+72" +72"

RP1:7

EP: 3

RP1: 32

RP1:36

RP1: 36

RP1: 10

RP1:10

EP:12

EP:14

G

EP: 20

RP2: 30

RP2: 4 RP2:4

RP2:4

RP2:30

WPG

WPG

WPG

RP1:14

RP1: 14

RP1:14

RP1:14

RP2:2

WPG

RP1:25

TV

EP: 21

RP2: 32

RP2:32

RP2:32

RP2:32

RP2: 33

RP2:33

RP2:30

RP2:33

RP1:35

G

RP1: 3

RP1:16

RP1:16 RP1:16

RP1: 38

EP:6

EP:7EP:11 EP:9

EP: 9EP: 11

EP: 7

EP:12

EP: 12

TV

TV

RP2:25

RP1:32

RP1:34

TV

RP1:34

EP:22 EP:22 EP: 22

SBB

C.CLO

RP1: 4

RP1: 4

RP1:6 RP1: 39

RP1:39

RP2: 31

RP1:2

RP1:2

RP1:2

RP1: 16

SSAC-1

RP1:41

RP1: 41

TV

RP1: 40

WH-1

CP-1

RELOCATED AIR

COMPRESOR

1. REFER TO SHEET E-001 AND E-002 FOR LEGEND,

ABBREVIATIONS, AND NOTES.

2. REFER TO E-700 SERIES DRAWINGS FOR PANELBOARD

SCHEDULES AND MECHANICAL EQUIPMENT SCHEDULE.

3. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR

EXACT EQUIPMENT LOCATION.

4. REFER TO E-500 SERIES DRAWING FOR SUPPLEMENTAL

DETAILS.

5. CONTRACTOR SHALL OFFSET OUTLET BOXES ON OPPOSITE

SIDES OF COMMON WALL TO PREVENT SOUND TRANSMISSION

BETWEEN ADJOINING ROOMS. BACK TO BACK BOXES SHALL

NOT BE PERMITTED.

6. REFER TO E-600 SERIES DRAWINGS FOR SINGLE LINE

DIAGRAMS. REFER TO MECHANICAL EQUIPMENT SCHEDULES

AND PANEL SCHEDULES FOR ADDITIONAL ELECTRICAL

REQUIREMENTS.

7. CONTRACTOR SHALL INSTALL ALL PANELS AND ELECTRICAL

EQUIPMENT TO MEET THE CLEARANCE REQUIREMENTS OF

THE NEC SECTION NEC 110.26(A) THROUGH (F).

8. PROVIDE EXPANSION FITTINGS/COUPLINGS AT ALL ABOVE

CEILING CONDUITS RUNS AT EXPANSION JOINTS. REFER TO

SPECIFICATION.

9. PROVIDE WEATHERPROOF LOCKING COVERS FOR ALL

EXTERIOR OUTLETS. REFER TO SPECIFICATION.

GENERAL NOTES

KEYNOTES

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 10:24:08 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

EP101

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

E L Y

E L Y

M C

K F

P O

W E

R P

L A

N

1/8" = 1'-0"D1

POWER PLAN

10 CONNECT NAC. REFER TO FIRE ALARM

DRAWINGS FOR ADDITIONAL INFORMATION.

11 PROVIDE JUNCTION BOX FOR AUTOMATIC

PLUMBING VALVE CONTROLS. COORDINATE ANY

ADDITIONAL ELECTRICAL REQUIREMENTS WITH

MANUFACTURER AND MECHANICAL DRAWINGS

PRIOR TO ROUGH-IN.

12 JUNCTION BOX FOR AUTOMATIC FAUCETS.

MOUNT RECEPTACLE AT 18" AFF. COORDINATE

MOUNTING LOCATION WITH PLUMBING

CONTRACTOR AND COUNTER TOP INSTALLER

PRIOR TO ROUGH-IN.

13 REFER TO TELECOM DRAWINGS FOR

GROUNDING BAR REQUIREMENTS.

14 PROVIDE 18 AWG IN 3/4"C,TWISTED SHIELD PAIR

INTERFACE FROM METER TO BAS CONTROLLER.

COORDINATE EXACT REQUIREMENTS WITH BAS

SYSTEM PLANS AND SPECIFICATIONS.

15 PROVIDE JUNCTION BOX FOR EYEWASH STATION

AND CONNECT TO CIRCUIT SHOWN. COORDINATE

ALL ELECTRICAL REQUIREMENTS WITH

MANUFACTURER PRIOR TO ROUGH IN.

16 PROVIDE POWER FOR WATER METER WM-1.

1 GFCI RECEPTACLE FOR ELECTRIC WATER

COOLER (EWC). MOUNT AT 20" AFF IN WATER

COOLER HOUSING. COORDINATE LOCATION

PRIOR TO ROUGH-IN.

2 MOUNT ALL DEVICES ABOVE COUNTER.

COORDINATE WITH ARCHITECTURAL DRAWINGS

AND MILLWORK SHOP DRAWINGS.

3 GARBAGE DISPOSAL MOTOR SWITCH ABOVE

COUNTER AND GFCI RECEPTACLE UNDER SINK.

COORDINATE WITH PLUMBING CONTRACTOR ANY

ADDITIONAL ELECTRICAL REQUIREMENTS PRIOR

TO ROUGH-IN.

4 RECEPTACLE FOR REFRIGERATOR. MOUNT

RECEPTACLE AT 48" AFF.

5 PROVIDE A MULTI-SERVICE (POWER/DATA/AV)

FLOOR BOX WITH LOW-PROFILE, FLUSH CAST

ALUMINUM COVER (WIREMOLD EVOLUTION

SERIES). COORDINATE TRIM WITH FLOOR FINISH

AND INSTALLATION WITH STRUCTURAL DETAILS.

REFER TO TELECOM PLANS FOR TELECOM/DATA

OUTLET REQUIREMENTS. COORDINATE

LOCATION OF FLOOR BOX DURING

CONSTRUCTION.

6 PROVIDE TV RECEPTACLE. COORDINATE HEIGHT

AND EXACT LOCATION WITH TELECOMM OUTLET

AND MOUNTING BRACKET PRIOR TO ROUGH-IN.

7 RECEPTACLES IN THIS ROOM WILL REQUIRE

ADDITIONAL AUTOMATIC CONTROL. REFER TO

DETAIL D3/ E-501 FOR ADDITIONAL ELECTRICAL

REQUIREMENTS. TYPICAL TO ALL RECEPTACLES

IN ROOM.

8 CONNECT FACP. REFER TO FIRE ALARM

DRAWINGS FOR ADDITIONAL INFORMATION.

9 CONNECT RAT. REFER TO FIRE ALARM

DRAWINGS FOR ADDITIONAL INFORMATION.

KEYNOTES

R E

F

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

WH

R E

F

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

E C

T R

O N

G

B I

A

N D

A

1/

AL

E

A

C E

2.

.2

.9

.8

SS

S

S

S

S

S

S

S

S

S

S

S

S

S S

S

S

S

S S

S

S

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4

3.6

B'

CLASSROOM

150CONFERENCE

OPEN OFFICE

OPEN OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

FA CLO.

OFFICE

CORR.

OPEN OFFICE

OFFICE

OFFICE

OFFICE

CORR.

BREAK RM.

SIM RM.

STORAGE

OFFICE

F. TOILET

M. SHOWER

M. TOILET

PHARMACY

CLINICAL LAB

OPEN OFFFICE

LAB STOR BIO

ENV

CORR.

F. SHOWER

EXAM RM.

OFFICE

COMM.

ELECT.

OPEN OFFICE

DENTAL EXAM.

DENTAL EXAM.

OFFICE

EQUIP.

OPEN OFFICE

CORR.

WAITING

OPEN OFFICE

CORRIDOR

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

CORR.

MECH.

OFFICE

CORRIDOR

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

STO.

J. CLO.

STORAGE

VAV-1-20

VAV-1-19

VAV-1-18

VAV-1-17

VAV-1-16VAV-1-15

VAV-1-14

VAV-1-10

VAV-1-5

VAV-1-11

VAV-1-12

VAV-1-13

VAV-1-9

VAV-1-8

VAV-1-4

VAV-1-6

VAV-1-7

VAV-1-3

VAV-1-2 VAV-1-1

M

M

M

MM

M

M

M

M

M

M

M

M

M M

M

M

M

M

M

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

M1: 7M1: 4M1: 21

M1: 11

M1: 17

M1: 13

M1: 23,25 M1: 10

M1: 12

M1: 8

M1: 1

M1: 2

M1: 19

M1: 6

M1: 16 M1: 18

M1: 3

M1: 24,26

M1: 14 M1: 5

CORRIDOR

VAV-1-21

VAV-1-22

VAV-1-23

M

M

M

M1: 9

M1: 15

M1: 20

TYP

1. REFER TO SHEET E-001 AND E-002 FOR LEGEND,

ABBREVIATIONS, AND NOTES.

2. REFER TO E-700 SERIES DRAWINGS FOR PANELBOARD

SCHEDULES AND MECHANICAL EQUIPMENT SCHEDULE.

3. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR

EXACT EQUIPMENT LOCATION.

4. REFER TO E-500 SERIES DRAWING FOR SUPPLEMENTAL

DETAILS.

5. CONTRACTOR SHALL OFFSET OUTLET BOXES ON OPPOSITE

SIDES OF COMMON WALL TO PREVENT SOUND TRANSMISSION

BETWEEN ADJOINING ROOMS. BACK TO BACK BOXES SHALL

NOT BE PERMITTED.

6. REFER TO E-600 SERIES DRAWINGS FOR SINGLE LINE

DIAGRAMS. REFER TO MECHANICAL EQUIPMENT SCHEDULES

AND PANEL SCHEDULES FOR ADDITIONAL ELECTRICAL

REQUIREMENTS.

7. CONTRACTOR SHALL INSTALL ALL PANELS AND ELECTRICAL

EQUIPMENT TO MEET THE CLEARANCE REQUIREMENTS OF

THE NEC SECTION NEC 110.26(A) THROUGH (F).

8. PROVIDE EXPANSION FITTINGS/COUPLINGS AT ALL ABOVE

CEILING CONDUITS RUNS AT EXPANSION JOINTS. REFER TO

SPECIFICATION.

9. PROVIDE WEATHERPROOF LOCKING COVERS FOR ALL

EXTERIOR OUTLETS. REFER TO SPECIFICATION.

GENERAL NOTES

KEYNOTES

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 10:24:13 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

EP102

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

E L Y

E L Y

M C

K F

V A

V P

O W

E R

P L A

N

1/8" = 1'-0"D1

VAV POWER PLAN

1 DISCONNECT SWITCH FOR VAV BOXES POWER.

CORDINATE ANY ADDITIONAL ELECTRICAL

REQUIREMENTS WITH HVAC CONTRACTOR.

J

J

J

MECH.

CORRIDOR

G

M1: 27,29,31 G

EF-1

M

RP1: 12

RP1: 26,28,30

RP1:12

AHU-1

EF-1

COMM.

ELECT.

CORR.

134 TR

MDP

SPDM1EP

LP RP1 SPDSPD

SPD SPD

RP2

SPD

SPD

MTS

MGB

TR:14

TR:16

TR: 16

TR: 14

RP1: 14

LP: 10

PBB

TR: 6

TR: 8

TR: 1,3

TR: 2,4

SSAC-2

3TYP

TR: 9

TR: 5,7

TR: 12

4 TYP

SSAC-1

EP: 23

1. REFER TO SHEET E-001 AND E-002 FOR LEGEND,

ABBREVIATIONS, AND NOTES.

2. REFER TO E-700 SERIES DRAWINGS FOR PANELBOARD

SCHEDULES AND MECHANICAL EQUIPMENT SCHEDULE.

3. REFER TO MECHANICAL AND PLUMBING DRAWINGS FOR

EXACT EQUIPMENT LOCATION.

4. REFER TO E-500 SERIES DRAWING FOR SUPPLEMENTAL

DETAILS.

5. CONTRACTOR SHALL OFFSET OUTLET BOXES ON OPPOSITE

SIDES OF COMMON WALL TO PREVENT SOUND TRANSMISSION

BETWEEN ADJOINING ROOMS. BACK TO BACK BOXES SHALL

NOT BE PERMITTED.

6. REFER TO E-600 SERIES DRAWINGS FOR SINGLE LINE

DIAGRAMS. REFER TO MECHANICAL EQUIPMENT SCHEDULES

AND PANEL SCHEDULES FOR ADDITIONAL ELECTRICAL

REQUIREMENTS.

7. CONTRACTOR SHALL INSTALL ALL PANELS AND ELECTRICAL

EQUIPMENT TO MEET THE CLEARANCE REQUIREMENTS OF

THE NEC SECTION NEC 110.26(A) THROUGH (F).

8. PROVIDE EXPANSION FITTINGS/COUPLINGS AT ALL ABOVE

CEILING CONDUITS RUNS AT EXPANSION JOINTS. REFER TO

SPECIFICATION.

9. PROVIDE WEATHERPROOF LOCKING COVERS FOR ALL

EXTERIOR OUTLETS. REFER TO SPECIFICATION.

GENERAL NOTES

KEYNOTES

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIM

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Krasimira Filipov, PE State of Registration: TEXAS Registration Number: 140676

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 10:23:46 AM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_ELEC_V20.rvt

09/30/2022

D3457500

E-401

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

E L Y

E L Y

M C

K F

E N

L A

R G

E D

E L E

C T R

IC

A

L P

L A

N S

1/4" = 1'-0"D6

ENLARGED MECHANICAL ROOM

1/4" = 1'-0"D1

ENLARGED ELECTRICAL/TELECOM ROOMS

1 PROVIDE ELECTRICAL GROUND BAR. REFER TO

DETAIL D1/E-501 AND BUILDING GROUND RISER

DIAGRAM ON D1/E-602.

2 PROVIDE POWER FOR ASTRONOMICAL TIME

CLOCK. REFER TO DETAIL D5/E-502 FOR

ADDITIONAL INFORMATION.

3 PROVIDE NEMA L5-20R TWIST LOCK RECEPTACLE

ABOVE RACK. COORDINATE WITH TELECOMM

PLANS FOR RECEPTACLE LOCATIONS. REFER TO

DETAIL D3/E-502 FOR ADDITIONAL INFORMATION.

4 PROVIDE NEMA L6-20R TWIST LOCK RECEPTACLE

MOUNTED TO CABLE TRAY ABOVE RACK.

COORDINATE WITH TELECOM PLANS FOR

RECEPTACLE LOCATIONS. REFER TO DETAIL

D3/E-502 FOR ADDITIONAL INFORMATION.

5 PROVIDE POWER FOR IDB. REFER TO TELECOM

DRAWINGS FOR ADDITIONAL INFORMATION.

6 REFER TO TELECOM DRAWINGS FOR GROUNDING

BAR REQUIREMENTS.

7 PROVIDE POWER FOR ANNUNCIATOR PANEL.

4"

1' - 8"

1/4"

4"

7/16" DIA.

COPPER BAR

INSULATOR

WALL MOUNTING

BRACKET

FINISHED GRADE

NOTES:

FACTORY LONG RADIUS ELBOWS

(QUANTITY, ARRANGEMENT AND SIZE

PER DWG)

6" GRAVEL

NO. 4 AWG TINNED COPPER

GROUNDING CONDUCTOR.

PROVIDE 36" SLACK

INSULATED GROUNDING BUSHING (TYP)

SPLIT BOLT

UL APPROVED GROUND

ROD 3/4" DIA, 10'-0" LONG

COPPER CLAD TEEL

SEE SPECIFICATIONS FOR COVER

REQUIREMENTS

LIFTING HOLE

3" HIGH LETTERS CAST IN COVER

CONCRETE FOOTINGS

RECOMMENDED FOR

TRAFFIC CONDITIONS (TYP.)

RECESSED HOLD DOWN LOCKABLE

PRE-CAST OR POLYMER CONCRETE

ALL SPLICES SHALL BE MADE IN PULL BOX WITH SPLIT

BOLT CONNECTORS PROPERLY TAPED AND WEATHERPROOFED.

AT ALL PULL BOXES, ENDS OF CONDUIT SHALL BE SEALED

WITH ELECTRICAL PUTTY AFTER WIRING IS COMPLETED.

PULL BOX SIZE: 12" X 12" X 12" UON.

COVER SHALL BE LOCKABLE AND TRAFFIC RATED (H20,000)

LABEL COVER "ELECTRIC", UON.

DELETE BOND TO COVER IF NONMETALLIC

OPTIONAL PULL BOX MATERIAL: POLYMER CONCRETE

1.

2.

3.

4.

5.

6.

7.

ELECTRIC

24" MIN

12"

A

L

C

1. SEE "EARTHWORK" SPECIFICATION

FOR EXCAVATION AND BACKFILL.

FINISHED GRADE

NOTES:

TYPICAL UNDERGROUND CONDUIT DETAIL, DIRECT BURIED GENERAL NOTES:

BACKFILL

WARNING TAPE

LIMITS OF EXCAVATION

CONDUIT QUANTITY AND SIZE

PER SPEC AND DWGS

TRENCH GRADE

1. ALL CONDUIT IS PVC SCHEDULE 40, UON. REFER TO PLANS FOR SIZES AND QUANTITIES.

2. COORDINATE DEPTH WITH OTHER UTILITIES. REFER TO ELECTRICAL AND CIVIL SITE PLANS FOR ADDITIONAL

INFORMATION.

3. MINIMUM DISTANCE SHOWN IS FROM TOP OF CONDUIT(S) TO FINISH GRADE.

4. PROVIDE WARNING TAPE NO LESS THAN 12" BELOW FINISHED GRADE.

NOTE:

ALL GROUND RODS SHALL HAVE A RESISTANCE OF 10 OHMS OR LESS UNLESS OTHERWISE NOTED ON PLANS OR SPECIFICATIONS. PROVIDE AN ADDITIONAL ROD IF RESISTANCE IS NOT ACHIEVED WITH ONE ROD.

SPACE ADDITIONAL ROD FROM THE FIRST ROD A DISTANCE OF 1.5 TIMES THE LENGTH OF THE ROD.

TO SECOND GROUND ROD (WHERE

REQUIRED)

BARE COPPER CABLE

EXOTHERMIC WELDS

(WHERE REQUIRED)

GROUND ROD, SEE PLANS AND

SPECIFICATIONS FOR SIZE

YEL

RED

UNSWITCHED

HOT LEGS

120/277

NEUTRAL

WHT

LIGHTING

LOAD (A)

DUAL RELAY

ON/OFF ROOM

CONTROLLER

LOAD (B)*

* LIGHTING OR

OTHER LOAD, i.e.

EXHAUST FAN

SEE PLANS

AUTOMATIC RECEPTACLE CONTROL SEQUENCE OF OPERATION:

CONTROL OPERATES AS MANUAL ON/AUTOMATIC OFF. PLUG LOAD IS SWITCHED ON

MANUALLY WITH LIGHT SWITCHES LIGHT LOADS SHALL BE PROGRAMMED TO TURN OFF

WITHIN 15 MINUTES, UON. PLUG LOADS SHALL BE PROGRAMMED TO TURN OFF WITHIN 30

MINUTES. UNCONTROLLED HALF OF RECEPTACLE IS ALWAYS ON.

FOR FULL OPERATIONAL DETAILS AND ADJUSTMENTS, REFERENCE THE MANUFACTURER'S

SYSTEM INSTALLATION INSTRUCTIONS.

NOTES:

1. CEILING MOUNT SENSOR SHOWN. REFER TO PLANS FOR EXACT MOUNTING AND

TYPE.

2. REFER TO PLANS FOR QUANTITY OF SWITCHES.

3. REFER TO THE LIGHTING CONTROLS MANUFACTURER FOR EXACT INSTALLATION

REQUIREMENTS.

4. LIGHT CONTROLS SHOWN FOR REFERENCE. EXACT CONFIGURATION AND QUANTITY

OF LIGHT CIRCUITS VARIES PER SPACE.

CABLES PER MANUFACTURER

LOW VOLTAGE WALL SWITCH

(NOTE 2)

OCCUPANCY

SENSOR (NOTE 1)

(a) (b) (c)

NEUTRAL

WHT

DIGITAL PLUG

LOAD CONTROLLER

RED

CONTROLLED

UNCONTROLLED

NEMA APPROVED/ NEC COMPLIANT

PERMANENT MARKING PRINTED ON FACE

RECEPTACLE TO IDENTIFY CONTROLLED

HALF OF RECEPTACLE

GENERAL DESIGN NOTE:

DIAGRAM SHOWN, REFLECTS A GENERIC SYSTEM LAYOUT, AND REQUIRED COMPONENTS.

FINAL COMPONENTS AND REQUIREMENTS SHALL BE COORDINATED WITH FINAL LIGHTING

CONTROL MANUFACTURER SYSTEM PER SPECIFICATIONS.

PLUG LOAD (C)

(NOTE 4)

PRE-CAST PULL BOX W/ 6" WALLS

AND FLOOR, UON

1.

NOTES:

KNOCKOUTS ON EACH SIDE(MIN),

COORDINATE W/ DUCTBANKS PER DWG, UON

PROVIDE HS-20 TRAFFIC RATED PULL BOX COVER, LOCKABLE.

SIZE: 36"L X 36"W X 48"D INSIDE CLEAR DIMENSIONS. MINIMUM UON.

LABEL COVER "ELECTRIC," UON.

2.

3.

12" DIA X 4" DEEP

DEPRESSION FOR

SUMP

NO. 2/0 AWG COPPER GROUNDING

WIRE, EXOTHERMIC WELD TO COVER

FRAME

CABLE RACK W/PORCELAIN

INSULATORS

(TYP 4 CORNERS)

3/4" x 10'-0" COPPER GROUND

ROD INSTALLED IN THE

VICINITY OF

THE PULLBOX.

24"

MIN

12"

A

LC

SEE DIVISION 31 "EARTHWORK"

SPECIFICATIONS FOR EXCAVATION AND

BACKFILL.

SEE SPECIFICATIONS 26 05 43 FOR

UNDERGROUND ELECTRICAL CONDUIT

REQUIREMENTS.

1.

2.

FINISHED GRADE

NOTES:

TYPICAL DUCTBANK DETAIL GENERAL NOTES:

BACKFILL

WARNING TAPE

LIMITS OF EXCAVATION

CONDUIT TYPE SIZE, AND

FILL PER SPEC AND DWG

TRENCH GRADE

ALL DUCTBANK CONDUIT IS PVC SCHEDULE 40, UON.

COORDINATE DUCTBANK DEPTH WITH OTHER UTILITIES, REFER TO ELECTRICAL AND CIVIL SITE PLANS

FOR ADDITIONAL INFORMATION.

PROVIDE 2/0 SOFT DRAWN BARE COPPER GROUND WIRE. BOND TO GROUND ROD AT EACH

MANHOLE/PULLBOX.

MINIMUM DISTANCE FROM TOP OF DUCTBANK TO FINISH GRADE IS 24" MIN. UON.

PROVIDE PLASTIC SPACERS EVERY 6' FOR DUCTBANKS.

PROVIDE DETECTABLE WARNING TAPE NO LESS THAT 12" BELOW FINISHED GRADE.

PROVIDE A 10' GROUND ROD AT EACH MANHOLE/PULLBOX. BOND GROUND WIRE, TO ALL EQUIPMENT GROUNDS AND GROUND RODS AT EACH MANHOLE/PULLBOX. BOND THE MANHOLE/PULLBOX COVER TO

THE GROUND ROD.

1.

2.

3.

4.

5.

6.

7.

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS…