This document provides details on a federal solicitation for repair work on a medical training facility. The solicitation number is W50S6Y24B0001 and is being issued by the Department of the Army Florida Army National Guard for repair work at Building 1002B_B3. Attached are 12MB of drawings in two volumes outlining the scope of work required. Bids are due by September 30, 2022 for repairs that include work on building flanges. The opportunity is open to all contractors and no specific set-asides or awards are mentioned. The summary provides key information on the facility, work required, issuing agency, and response date for a federal solicitation for repair services.

View the file

Other files

Show all 21

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WALL-MOUNTED FIRE ALARM HORN/STROBE (XX DENOTES CANDELA RATING)

WALL-MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER/STROBE (XX DENOTES CANDELA RATING)

(WP DENOTES WEATHER PROOF DEVICE)

WALL-MOUNTED FIRE ALARM/MASS NOTIFICATION STROBE (XX DENOTES CANDELA RATING)

(WP DENOTES WEATHER PROOF DEVICE)

P

WP

NAC

LOC

F

SD

KB

FIRE ALARM GENERAL NOTESFIRE ALARM LEGEND

NOT ALL SYMBOLS USED

FIRE ALARM BELL

WALL-MOUNTED EXTERIOR WEATHERPROOF SPEAKER

PRESSURE SWITCH

TAMPER SWITCH

FLOW SWITCH

DUCT SMOKE DETECTOR

PHOTOELECTRIC SMOKE DETECTOR

MANUAL PULL STATION

HEAT DETECTOR

LOCAL OPERATING CONSOLE

NAC EXTENDER PANEL

AFF

AHJ

AVG

COTR

ELEV

EOL

FPC

MIN

NAC

NIC

NP

NTS

SIM

SLC

SQFT

SP

TD

WP WEATHER PROOF

TRAVEL DISTANCE

SMOKE PARTITION

SQUARE FEET

SIGNALING LINE CIRCUIT

SIMILAR

NOT TO SCALE

NOT PERMITTED

NOT IN CONTRACT

NOTIFICATION APPLIANCE CIRCUIT

MINIMUM

FIRE PUMP CONTROLLER

END OF LINE RESISTOR

ELEVATION

CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE

AVERAGE

ABOVE FINISHED FLOOR

AUTHORITY HAVING JURISDICTION

FIRE ALARM ABBREVIATIONS

CARBON MONOXIDE DETECTOR

CIS COMMON INTELLIGIBILITY LEVEL

DOR

AFG ABOVE FINISHED GRADE

DESIGNER OF RECORD

SD SMOKE DAMPER

SMOKE DAMPER

XP EXPLOSION PROOF

FIRE DEPARTMENT KEY LOCK BOX

1. PROVIDE AND INSTALL A COMPLETE, COMBINED ADDRESSABLE FIRE ALARM/MASS NOTIFICATION SYSTEM THROUGHOUT THE FACILITY. CIRCUITS USED TO MONITOR AND CONTROL INITIATING DEVICES MUST BE INITIATING DEVICE CIRCUITS (IDC), CLASS B, OR SIGNALING LINE CIRCUITS (SLC), IN ACCORDANCE WITH NFPA 72. NETWORK CIRCUITS BETWEEN FIRE ALARM CONTROL PANELS, SUB PANELS, ANNUNCIATORS, ETC. MUST BE CLASS B IN ACCORDANCE WITH NFPA 72. CIRCUITS USED TO INITIATE OPERATION OF THE NOTIFICATION DEVICES MUST BE NOTIFICATION APPLIANCE CIRCUITS (NAC), CLASS B IN ACCORDANCE WITH NFPA 72. ALL FIRE ALARM CIRCUITS MUST BE MONITORED FOR CIRCUIT INTEGRITY (FAULT, SHORT AND GROUND) BY THE FIRE ALARM CONTROL PANEL. CIRCUIT FAILURE SIGNALS MUST BE ANNUNCIATED AS TROUBLE SIGNALS.

2. DESIGN, INSTALL AND TEST THE FIRE ALARM SYSTEM IN ACCORDANCE WITH

• UFC 1-200-01, CHANGE 1, 01 OCTOBER 2020

• UFC 3-600-01, CHANGE 6, 06 MAY 2021

• UFC 4-021-01, CHANGE 1, 01 JANUARY 2010

• FLORIDA BUILDING CODE, 2018 EDITION

• NFPA 1, 2021 EDITION

• NFPA 72, 2019 EDITION

3. PERFORM ALL ACCEPTANCE AND OPERATIONAL TESTS IN ACCORDANCE WITH NFPA 72.

4. A "RECORD OF COMPLETION" PREPARED IN ACCORDANCE WITH NFPA 72, AND THE FIRE ALARM TEST REPORT MUST BE FILED WITH THE

AUTHORITY HAVING JURISDICTION.

5. THE FLASH RATE OF VISIBLE NOTIFICATION APPLIANCES MUST NOT EXCEED TWO FLASHES PER SECOND, NOR BE LESS THAN ONE FLASH EVERY SECOND, IN ACCORDANCE WITH NFPA 72. A MAXIMUM PULSE DURATION MUST BE 0.2 SECONDS WITH A MAXIMUM DUTY CYCLE OF 40 PERCENT, IN ACCORDANCE WITH NFPA 72. VISIBLE NOTIFICATION APPLIANCES MUST BE SPACED IN ACCORDANCE WITH NFPA 72 AND AS INDICATED.

6. VISUAL NOTIFICATION DEVICES MUST HAVE A MINIMUM 15-CANDELA RATING AND WILL BE LOCATED THROUGHOUT ALL COMMON AREAS OF THE OFFICES SUCH AS LOBBIES AND CORRIDORS. VISUAL APPLIANCES MUST ALSO BE LOCATED IN ALL TOILET ROOMS, CONFERENCE ROOMS, ASSEMBLY AREAS, BREAK AREAS, ETC., AS REQUIRED FOR COMPLIANCE WITH THE ABA/ADA. CLEAR STROBES MARKED "ALERT" MUST BE USED TO INDICATE FIRE ALARMS AND MASS NOTIFICATION IN ACCORDANCE WITH THE REQUIREMENTS OF UFC 3-600-01.

7. THE SPRINKLER SYSTEM CONTROL VALVE TAMPER AND FLOW SWITCHES MUST BE CONNECTED TO THE SIGNALING LINE CIRCUITS. REFER TO

FIRE SUPPRESSION DRAWINGS FOR LOCATIONS.

8. SUBMIT SHOP DRAWINGS TO THE AHJ FOR APPROVAL. WORK MUST NOT COMMENCE UNTIL APPROVAL OF THE SHOP DRAWINGS IS RECEIVED FROM THE AHJ. FIRE ALARM SYSTEM SHOP DRAWINGS, AT A MINIMUM, MUST INCLUDE THE REQUIREMENTS OF NFPA 72, SECTION 7.4.7.5 AND A.7.4.

9. AUDIBLE FIRE ALARM SOUND LEVEL MUST BE AT LEAST 15 dBA ABOVE THE AVERAGE AMBIENT SOUND LEVEL OR 5 dBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION OF AT LEAST 60 SECONDS, WHICHEVER IS GREATER, MEASURED 5 FEET ABOVE THE FLOOR IN THE OCCUPIABLE AREA, BUT NOT GREATER THAN 120 dBA AT THE MINIMUM HEARING DISTANCE FROM THE AUDIBLE APPLIANCE. PROVIDE ADEQUATE

NOTIFICATION APPLIANCES THROUGHOUT THE SPACE TO MEET NFPA 72 REQUIREMENTS.

10. ANY PENETRATIONS MADE THROUGH FIRE RATED PARTITIONS MUST BE FIRE STOPPED WITH A U.L. LISTED SYSTEM. SUBMIT PENETRATION

LOCATION TO THE ARCHITECT OF RECORD FOR APPROVAL.

11. DUCT SMOKE DETECTORS FOR AIR HANDLING UNITS MUST BE SUPPLIED BY DIVISION 28 AND INSTALLED BY DIVISION 23. DUCT SMOKE

DETECTORS ARE REQUIRED AS INDICATED ON PLANS.

12. FOR MINIMUM MOUNTING HEIGHTS ABOVE FINISHED FLOOR REFER TO DETAIL ON FA501.

13. COORDINATE ALL FIRE PROTECTION, ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL WORK WITH CEILING HEIGHTS, FURNITURE LAYOUT, AND ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR COORDINATE FINAL LOCATIONS WITH ARCHITECT, AHJ, AND FIRE PROTECTION

ENGINEER.

14. ALL TERMINATIONS MUST BE AT A TERMINAL STRIP. ALL DEVICES MUST HAVE SCREW TERMINALS. IDENTIFY ALL CONDUCTORS INDIVIDUALLY

WITH PERMANENT MARKINGS. THE USE OF WIRE NUTS MUST NOT BE ALLOWED.

15. CONDUCTORS (WIRE) FOR ALL FIRE DETECTION AND ALARM CIRCUITS MUST BE INSTALLED WITHIN ¾ - INCH MINIMUM DIAMETER METAL CONDUIT.

ALL SIGNALING LINE AND INITIATING DEVICE CIRCUITS MUST BE MINIMUM 16 GAUGE WIRE.

16. FIRE ALARM SYSTEM COMPONENTS MUST BE IDENTIFIED IN ACCORDANCE WITH UFC 3-600-01, 9-18.9.7. PAINT ALL FIRE ALARM JUNCTION BOXES AND COVERS RED IN UNFINISHED AREAS (I.E. ABOVE CEILINGS, MECHANICAL ROOMS, ETC. ). CONDUIT IN UNIFINISHED AREAS TO BE FACTORY PAINTED RED. IN FINISHED AREAS, PAINT MANUAL PULL STATIONS RED, CONDUIT MUST HAVE PAINTED RED BANDS 3/4" WIDE AT 20 FOOT

CENTERS AND AT EACH SIDE OF A FLOOR, WALL OR CEILING PENETRATION.

17. PROVIDE TYPE THW OR XHHW FOR WIRING IN WET LOCATIONS. TYPE THWN/THHN INSULATED WIRE IS NOT ACCEPTABLE FOR UNDERGROUND

WIRING OF FIRE ALARM CIRCUITS.

18. DRAWINGS INDICATE THE DESIGN INTENT. IT IS THE CONTRACTOR'S RESPONSIBILITY UNDER THE SCOPE OF WORK TO COMPLY WITH ALL CODES / STANDARDS SPECIFIED ABOVE TO ACCOMMODATE SPACE CONFIGURATION FOR NEW CONSTRUCTION INCLUSIVE OF NOTIFICATION COVERAGE, REMOTE MONITORING, CONTROLS, ACCESSORIES, AND ALL ACCEPTANCE TESTS / APPROVALS FOR A COMPLETE, FULLY COMPLIANT, AND FUNCTIONAL SYSTEM. SUBMIT SHOP DRAWINGS IN COMPLIANCE WITH NFPA 72 TO THE AHJ FOR APPROVAL.

19. AUDIBLE MASS NOTIFICATION REQUIREMENTS MUST MEET THE INTELLIGIBILITY LEVELS OF UFC 4-021-01. (0.8 CIS MINIMUM)

20. AUDIBLE CARBON MONOXIDE DETECTION NOTIFICATION MUST BE A 520 HZ TEMPORAL 4 (T-4) SIGNAL. THE ALERT SIGNAL MUST REPEAT TWICE

BEFORE THE VOICE ANNOUNCEMENT.

21. FOR MINIMUM MOUNTING HEIGHTS ABOVE FINISHED FLOOR REFERS TO DETAILS.

22. ALL AMPLIFIERS MUST BE PROVIDED WITH A BACK-UP AMPLIFIER AND BE CONSTANTLY SUPERVISED FOR ANY CONDITION THAT COULD RENDER THE AMPLIFIER INOPERABLE. FAILURE OF ANY COMPONENT MUST CAUSE AUTOMATIC TRANSFER TO A DESIGNATED BACKUP AMPLIFIER.

23. CONTROL RELAY MODULES MUST BE INSTALLED WITHIN 3 FEET FROM THEIR INTERFACE POINT ON THE CONTROL EQUIPMENT IN ACCORDANCE

WITH NFPA 72, 21.2.4

24. FOR COMPLETE SYSTEM CONTROL, REFER TO FIRE ALARM AND MASS NOTIFICATION LOGIC MATRIX.

25. STROBES ACTIVATED IN CONJUNCTION WITH THE DELIVERY OF A PRE-RECORDED VOICE MESSAGE MUST OPERATE CONTINUOUSLY UNTIL MESSAGE TERMINATION. STROBES ACTIVATED IN CONJUCTION WITH THE DELIVERY OF A LIVE VOICE MESSAGE MUST OPERATE DURING THE MESSAGE AND FOR NOT LESS THAN 15 SECONDS AFTER THE MESSAGE ENDS. STROBES ACTIVATED BY FIRE ALARM SYSTEM MUST OPERATE CONTINUOUSLY UNTIL THE FIRE ALARM SYSTEM IS RESET. LIGHT-EMITTING DIODE (LED) TYPE TEXT SIGNS MUST ACTIVATE IN CONJUCTION

WITH VOICE MESSAGES OVER THE MASS NOTIFICATION OR FIRE ALARM SYSTEM.

26. ALL CONDUIT MUST ENTER WALL MOUNTED DEVICES UNDER JUNCTION BOX AND PROVIDE CONDUIT DRAIN.

XX

WP

XX

WP

P

GRAPHIC ANNUNCIATOR PANEL

FMCP FIRE ALARM/MASS NOTIFICATION CONTROL PANEL

T TEMPERATURE SENSOR

MM MONITOR MODULE

CM CONTROL MODULE

CEILING-MOUNTED HORN

VEWSD VERY EARLY WARNING SMOKE DETECTION

RAT RADIO ALARM TRANSMITTER

ANN

KB KNOX BOX

VTD VISUAL TEXT DISPLAY

PCO

XX

XX CEILING-MOUNTED FIRE ALARM/MASS NOTIFICATION SPEAKER/STROBE (XX DENOTES CANDELA RATING)

(C DENOTES CEILING-MOUNTED DEVICE)C

SS SURGE SUPPRESSOR

TS

C

WF

C

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

9/28/2022 4:06:25 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/30/2022

D3457500

FA001

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

JC

M

FI

R

E

AL

AR

M

A N

D M

AS

S

N O

TI

FI

C

AT

IO

N

G

EN

ER

AL

N O

TE

S, SY

M

BO

LS

, A N

D A

BB

R

EV

IA

TI

O

N S

WH

R

EF

CP

13/

09/

SCA

LE:

0,5

SC

AL

E 1, PR

IN

TE

R

PO

W

ER

CO

RD

IN

LE

T

9,4

14,9 4")

358,1 (14,1")

136,2 (5,36")

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:1

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

CP

13/

09/

SCA

LE:

0,5

SC

AL

E 1, PR

IN

TE

R

PO

W

ER

CO

RD

IN

LE

T

9,4

14,9 4")

358,1 (14,1")

136,2 (5,36")

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:15

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

CP150

2013/09/09 SCALE:0,500

SCALE

1,000

PRINTER

POW

ER CORD INLET

379,42 (14,94")

358, 1 ( 14,1")

136, 2 ( 5, 36")

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:1 5

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

CP150

2013/09/09 SCALE:0,500

SCALE

1,000

PRINTER

POW

ER CORD INLET

379,42 (14,94")

358, 1 ( 14,1")

136, 2 ( 5, 36")

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:1 5

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

F

F

F

F

ANN LOC

LOC

P

FMCP

VT

D

VT

D

VT

D

RATNAC

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4

3.6

B'

WP

WP

WP

WP

15,C

15,C

15,C

15,C

15,C

15,C

30,C

15,C 15,C 15,C15,C15,C15,C 15,C

15,C

15,C 15,C

15,C 15,C

15,C

15,C

15,C

15,C

30,C30,C15,C

15,C

15,C 15,C

15,C 15,C

15,C

30,C

15,C 15,C 15,C

15,C 15,C

15,C

15,C15,C15,C 15,C

15,C15,C

15,C

30,C 30,C 30,C 30,C

15,C

15,C

15,C

30,C

OPEN OFFICE

OPEN OFFICE

CONFERENCE

CLASSROOM

CORRIDOR

OFFICE

OFFICE

OFFICE

VESTIBULE

FA CLO.

OFFICE

WAITING

OPEN OFFICE

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

OFFICE

OFFICE

OFFICE

OFFICE

129 STO.

OPEN OFFICE

OFFICE

CORRIDOR

MECH.

CORRIDOR

OPEN OFFICE

EXAM RM.

OFFICE

ELECT.

COMM.

F. SHOWER

M. SHOWER

F. TOILET

M. TOILET

PHARMACY

CLINICAL LAB

OPEN OFFFICE

EQUIP.

OFFICE

OPEN OFFICE

DENTAL EXAM.

DENTAL EXAM.

OPEN OFFICE

157 OFFICE

OFFICE

OFFICE

160 BREAK RM.

SIM RM.

STORAGE

OFFICE

15,WP

15,WP

15,WP

15,C

TS

C

WF

C MM

MM

KB

15,WP

15,C

15,C

15,C

15,C

15,C

15,C

J. CLO.

STORAGE

15,C

CM

S

AHU-1

SS

SS

SS

SS

CM

TYP

CM R

AHU-1

CM

R

AHU-1

GENERAL NOTES

1. REFER TO FA001 FOR FIRE ALARM GENERAL NOTES, SYBMOLS, AND ABBREVIATIONS.

2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION WITH LIGHTS,

MECHANICAL DIFFUSERS, AND CEILING GRID.

KEYNOTES

1. PROVIDE MONITOR MODULES TO MONITOR WET PIPE SPRINKLER SYSTEM TAMPER SWITCH, AND

WATERFLOW ALARM SWITCH.

2. KNOX BOX LOCATION. PROVDE MODULE TO MONITOR KEY BOX TAMPER.

3. PROVIDE DUCT SMOKE DETECTORS TO MONITOR AHU-1. DETECTOR MUST BE MOUNTED ALONG

DUCTWORK. PROVIDE A CONTROL MODULE TO SHUTDOWN UNIT AND MOUNT MODULE WITHIN

THREE FEET OF UNIT CONTROLLER. PROVIDE REMOTE STATUS INDICATOR AND TEST SWITCH

FOR DUCT DETECTOR AT AN ACCESSIBLE LOCATION. REFER TO MECHANICAL PLANS FOR UNIT

LOCATION.

4. PROVIDE CONTROL MODULE FOR LIGHTING CONTROLLER INTERFACE. ACTIVATE EGRESS

LIGHTING AND EMERGENCY LIGHTS UPON FIRE ALARM ACTIVATION.

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

Pr oj ec t T itl e:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

H

EA

D Q

U A

R

TE

R S

-1

A

M

ED

. C

LI

N

IC

B

R

EN

O

VA

TI

O

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/28/2022 4:06:46 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/30/2022

D3457500

FA101

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

Ap pr ov er

FI

R

E

AL

AR

M

A N

D M

AS

S

N O

TI

FI

C

AT

IO

N

C

EI

LI

N

G P

LA

N

1/8" = 1'-0"D1

FIRE ALARM AND MASS NOTIFICATION

CEILING PLAN

0 4' 8' 16'

DETECTOR BASE

SMOKE

EXPOSED CEILING

DETECTOR

J-BOX ON

1 INCH EMT CONDUIT

SMOKE

MEMBER

STRUCTURAL

CONDUIT FROM

PREVIOUS DEVICES

CONDUIT TO

REMAINING DEVICES

FIRE ALARM NOTIFICATION

APPLIANCE LOCATION ZONE

(AUDIBLE ONLY APPLIANCES

SHALL BE MOUNTED NOT LESS

THAN 90" AFF AND NOT LESSTHAN

6" BELOW THE FINISHED CEILING)

FINISHED FLOOR

FINISHED CEILING

(WHERE PROVIDED)

" A

FF

" A

FF 96

" A

FFFIRE

SIGNALING LINE AND

NOTIFICATION APPLIANCE

CIRCUIT CONDUIT

(SINGLE CONDUIT, WHEN

PERMITTED BY MANUFACTURER)

MAXIMUM HORIZONTAL

DISTANCE TO EXIT IS 5

FEET

MOUNTED PULL

STATION AND

BACKBOX

JUNCTION BOX

VISUAL TEXT DISPLAY

COORDINATE WITH

EXIT SIGN

CM

WF

C

MMMM

TS

C

F

FMCP

NOTE: RISER DIAGRAM IS A SCHEMATIC REPRESENTATION OF THE FIRE

ALARM/MASS NOTIFICATION SYSTEM. REFER TO THE FIRE ALARM/MASS

NOTIFICATION PLANS FOR LOCATIONS AND QUANTITIES OF DEVICES AND

APPLIANCES.

NAC

120V

NAC - FA/MNS STROBE

(CLASS B)

NAC - SPEAKER

(CLASS B)SLC - INITIATING

(CLASS B)

120V LOC

RAT

120V

EOL

EOL

P

FIRST FLOOR BATT

EOL

EOL

TEXTUAL SIGN

CIRCUIT (CLASS B)VTD

ANN

S

MANUAL PULL STATION

SMOKE DETECTOR

WATERFLOW ALARM

DUCT SMOKE DETECTOR

VALVE TAMPER SWITCH

FMCP PANEL TROUBLE

FMCP AC POWER FAIL

FMCP LOW BATTERY

OPEN CIRCUIT

GROUND FAULT

CIRCUIT SHORT

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

SYSTEM INPUTS

BU

IL

D

IN

G F

M C

P

AL

AR

M

L

ED

A N

D A

U D

IB

LE

S

IG

N

AL

BU

IL

D

IN

G F

M C

P

SU

P

ER

VI

SO

R Y

L

ED

A N

D A

U D

IB

LE

S

IG

N

AL

BU

IL

D

IN

G F

M C

P

TR

O U

BL

E

L

ED

A N

D A

U D

IB

LE

S

IG

N

AL

D

IS

PL

AY

O N

A N

N U

N C

IA

TO

R

R

EP

O R

T

AL

AR

M

S

IG

N

AL

T O

B

AS

E R

EP

O

R

TI

N G

S

YS

TE

M

AC

TI

VA

TE

B U

IL

D

IN

G

F

IR

E A

LA

R

M N

O

TI

FI

C

A

TI

O N

A

PP

LI

AN

C E

S

R

EP

O R

T

SU

PE

R

VI

SO

R Y

SI

G

N

AL

T O

B

AS

E R

EP

O

R

TI

N G

S

YS

TE

M

R

EP

O R

T

TR

O U

BL

E

SI

G

N

AL

T O

B

AS

E R

E

PO

R

TI

N G

S

IG

N

AL

D

EL

IE

VE

R M

AS

S

N O

TI

FI

C

AT

IO

N

L

IV

E M

ES

SA

G E

SE

N

D S

IG

N

AL

T

O S

H U

TD

O

W N

A

LL

H

VA

C U

N

IT

S

IL

LU

M

IN

AT

E

R

EM

O

TE

L

ED

IN

D

IC

A

TO

R

D

EA

C

TI

VA

TE

B U

IL

D

IN

G

P A

SY

ST

E M

IN

IT

IA

TE

O

VE

R R

ID

E

O F

LI

G

H

TI

N G

C O

N

TR

O

LS

IN

O

R D

E R

T O

IL

LU

M

IN

A

TE

PA

TH

S O

F

EG

R

ES

S

CONTROL UNIT

ANNUNCIATION NOTIFICATION LIFE SAFETY CONTROL

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

A B C D E F G H I J P Q R S T U V

A B C D E F G H I J P Q R S T U V

SYSTEM OUTPUTS

INDICATES ACTION WILL

CAUSE A SPECIFIC RESULT

INDICATES ACTION WILL NOT

CAUSE A SPECIFIC RESULT

MATRIX OF OPERATIONS

ACTIVATION OF MASS NOTIFICATION SYSTEM

K L M N O

K L M N O

D

EA

C

TI

VA

TE

B U

IL

D

IN

G

F

IR

E

AL

AR

M

N O

TI

FI

C A

TI

O

N A

PP

LI

AN

C

E S

AC

TI

VA

TE

B U

IL

D

IN

G

M

AS

S N

O

TI

FI

C

A

TI

O N

N O

TI

FI

C A

TI

O

N A

PP

LI

AN

C

E S

SE

N

D S

IG

N

AL

T

O S

H U

TD

O

W N

A

SS

O C

IA

TE

D H

V

AC

U N

IT

ACTIVATION OF HVAC SHUTDOWN SWITCH

--- AC

TI

VA

TE

V

IS

U

AL

T

EX

T D

EV

IC

E S

DUCT SMOKE DETECTOR TEST SWITCH

OPERATION OF MASS NOTIFICATION SYTEM - LIVE

MESSAGES

OPERATION OF MASS NOTIFICATION SYTEM - PRE-

RECORDED MESSAGES

D

EL

IV

E

R M

AS

S

N O

TI

FI

C

AT

IO

N

P R

E- R

EC

O

R D

ED

M

ES

SA

G E

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

9/28/2022 4:06:47 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/30/2022

D3457500

FA501

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

Ap pr ov er

FI

R

E

AL

AR

M

A N

D M

AS

S

N O

TI

FI

C

AT

IO

N

D

ET

AI

LS

NTSD3 EXPOSED CEILING DETECTOR DETAIL

NTSC3 FIRE ALARM MOUNTING DETAIL

NTSD1 FIRE ALARM RISER DIAGRAM - CLASS B

NTSC1

FIRE ALARM AND MASS NOTIFICATION

MATRIX OF OPERATION

NOT ALL SYMBOLS ARE USED

TC

ABBREVIATIONSYMBOL DESCRIPTION

BUTTERFLY VALVE WITH TAMPER

FLOW SWITCHFS

EAB ELECTRIC ALARM BELL

FDC FIRE DEPARTMENT CONNECTION (WALL-MOUNTED)

INSPECTOR'S TEST CONNECTION

WET PIPE RISER

OUTSIDE SCREW AND YOKE GATE VALVE W/TAMPER SWITCH

POST INDICATOR VALVE

DRY PIPE VALVE

PRESSURE REDUCING VALVE

CHECK VALVE

ANGLE VALVE

GLOBE VALVE

AV

GLV

CV

DPV

PRV

PIV

OS&Y

SP

CAPPED PIPE/OUTLET

PIPE TURNING DOWN

PIPE TURNING UP

AFF

AHJ

AVG

BFP

CFM

COTR

ELEV

FDC

FHV

FP

EOL

FPC

FVC

GALS

GPH

GPM

GV

JP

JPC

JOCKEY PUMP

GATE VALVE

GALLONS PER MINUTE

GALLONS PER HOUR

GALLONS

FIRE VALVE CABINET

FIRE PUMP CONTROLLER

FIRE PUMP

FIRE HOSE VALVE

END OF LINE RESISTOR

ELEVATION

CUBIC FEET PER MINUTE

AVERAGE

AUTHORITY HAVING JURISDICTION

DOUBLE CHECK BACKFLOW PREVENTER

CONTRACTING OFFICER'S TECHNICAL REPRESENTATIVE.

FIRE DEPARTMENT CONNECTION

WEATHER PROOFWP

UH

SQFT

SLC

NIC

NC

MIN

NP

PIV

PSIG

SOV

VLV

OS&Y

NAC

JOCKEY PUMP CONTROLLER

MINIMUM

NOTIFICATION APPLIANCE CIRCUIT

NOT PERMITTED

NONCOMBUSTIBLE

POST INDICATOR VALVE

NOT IN CONTRACT

OUTSIDE SCREW AND YOKE

POUNDS PER SQUARE INCH GAUGE

SIGNALING LINE CIRCUIT

SOLENOID VALVE

SQUARE FEET

UNIT HEATER

VALVE

ABOVE FINISHED FLOOR

N.C. NORMALLY CLOSED

N.O. NORMALLY OPEN

OH ORDINARY HAZARD

TYP TYPICAL

FIRE SUPPRESSION GENERAL NOTESFIRE SUPPRESSION LEGEND FIRE PROTECTION ABBREVIATIONS

1. THE BUILDINGS MUST BE FULLY SPRINKLERED. THE SYSTEMS MUST BE DESIGNED, INSTALLED AND TESTED IN ACCORDANCE WITH

• UFC 3-600-01, 8 AUGUST 2016 WITH CHANGE 6, 6 MAY 2021

• FLORIDA BUILDING CODE, 2018 EDITION

• NFPA 1, FIRE CODE, 2021 EDITION

• NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS, 2019 EDITION

• NFPA 24, STANDARD FOR THE INSTALLATION OF PRIVATE SERVICE MAINS AND THEIR APPURTENANCES, 2019 EDITION

• CONTRACT SPECIFICATIONS

2. THE DESIGN IS BASED ON UFC 3-600-01, AND THE REQUIREMENTS LISTED BELOW. THE MORE STRINGENT REQUIREMENTS OF UFC 3-600-01 MUST APPLY.

3. VERIFY ALL LOCATIONS AND MEASUREMENTS AS CONDITIONS MAY VARY THROUGHOUT CONSTRUCTION. ALL CHANGES FROM THE ORIGINAL DESIGN MUST BE APPROVED BY THE AHJ.

4. INSTALL TAMPER AND FLOW SWITCHES AS INDICATED ON CONTRACT DRAWINGS. CONNECTIONS TO THE FIRE ALARM SIGNALING LINE CIRCUIT MUST BE MADE UNDER SPECIFICATION DIVISION 28.

5. DESIGN THE AUTOMATIC SPRINKLER SYSTEM BY MEANS OF HYDRAULIC CALCULATIONS IN ACCORDANCE WITH UFC 3-600-01, NFPA 13, AND CONTRACT SPECIFICATIONS REQUIREMENTS. REFER TO WATER SUPPLY AND DESIGN REQUIREMENTS ON THIS SHEET FOR CLARIFICATION. THE CONTRACTOR IS RESPONSIBLE FOR THE ENTIRE DESIGN OF THE SPRINKLER SYSTEM.

6. DRAWINGS INDICATE THE DESIGN INTENT. SHOP DRAWINGS MUST BE SUBMITTED TO INDICATE SPECIFIC PRODUCTS TO BE INSTALLED, HANGER DESIGN CRITERIA, ETC. IN ACCORDANCE WITH NFPA

13, CHAPTER 27.

7. OBTAIN ALL REQUIRED PERMITS AND APPROVALS FROM THE AHJ PRIOR TO COMMENCING WORK.

8. BUILDING SEISMIC DESIGN CATEGORY C. PROVIDE SEISMIC BRACING FOR SPRINKLER SYSTEM PIPING IN ACCORDANCE WITH NFPA 13.

HH HIGH HAZARD

AAV AUTOMATIC AIR VENT

OCCUPANCY

CLASSIFICATION

DESIGN DENSITY

(GPM / SQ. FT)

DESIGN AREA

(SQ. FT)

HOSE STREAM

ALLOWANCE (GPM)

DURATION

(MIN.)

LIGHT HAZARD (LH) 0.10 1,500 250 60

ORDINARY HAZARD

WET (OH)

0.20 2,500 250 60

COVERAGE PER

SPRINKLER

(SQ. FT)

SPRINKLER SYSTEM DESIGN CRITERIA

SPRINKLER HEAD

K-FACTOR

5.6

8.0

RESPONSE

TIME INDEX

(RTI)

QR

SR

9. PROVIDE UPRIGHT SPRINKLERS IN ALL ROOMS WITH NO CEILINGS, AND CONCEALED OR RECESSED TYPE SPRINKLERS WITH COVERS IN SUSPENDED CEILINGS, GYPSUM CEILINGS AND SOFFITS.

COORDINATE COVER PLATE COLORS WITH ARCHITECT.

10. COORDINATE ALL FIRE PROTECTION, ELECTRICAL, PLUMBING, MECHANICAL, AND STRUCTURAL WORK WITH CEILING HEIGHTS AND ARCHITECTURAL WORK. WHERE CONFLICTS OCCUR COORDINATE

FINAL LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS.

11. THE FIRE SUPPRESSION SYSTEMS MUST BE SUPPLIED BY A DEDICATED FIRE MAIN. THE EXISTING HIGH PRESSURE FIRE MAIN IS SUPPLIED BY TWO 3,000 GPM @140 PSI FIRE PUMPS. BASE HYDRAULIC CALCULATIONS ON THE MOST RECENT FIRE PUMP TEST REPORTS, STATIC PRESSURE ON THE SYSTEM IS 190 PSI. A HYDRANT FLOW TEST MUST BE PERFORMED IN ACCORDANCE WITH NFPA 291.

12. SPRINKLER PIPING MUST BE LABELED IN ACCORDANCE WITH UFC 3-600-01, 9-6.8.

13. FIRE SPRINKLER SYSTEM MUST BE FULLY COORDINATED WITH ALL DISCIPLINES PRIOR TO INSTALLATION.

14. PROVIDE AUXILIARY DRAINAGE FOR ALL LOW POINT AND TRAPPED SECTIONS OF WATER.

15. SPRINKLER TEMPERATURE RATING IN ACCORDANCE WITH NFPA 13.

16. SPRINKLERS MUST BE LOCATED SYMMETRICALLY WITHIN CEILING TILES.

17. FOR ALL PIPE PASSING THROUGH EXPANSION JOINTS PROVIDE UL LISTED AND FM APPROVED FLEXIBLE COUPLING.

18. PROVIDE BLACK STEEL SCHEDULE 40 MINIMUM THICKNESS FOR ALL FIRE SUPPRESSION PIPING.

19. PROVIDE AN AIR RELIEF VENT AT THE HIGH POINT OF EACH ZONE OF THE FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH NFPA 13.

20. PROVIDE AN INSPECTORS TEST CONNECTION AT THE MOST HYDRAULICALLY REMOTE POINT ON THE SPRINKLER SYSTEM.

21. ALL DRAIN PIPING MUST BE PIPED TO THE BUILDING EXTERIOR TO WITHIN 6 INCHES ABOVE FINISHED GRADE. ALL DRAIN PIPING DISCHARGE LOCATIONS MUST BE PROVIDED WITH SPLASH

BLOCKS.

SIM

SP

TD TRAVEL DISTANCE

SMOKE PARTITION

SIMILAR

CIS COMMON INTELLIGIBILITY LEVEL

DOR

AFG ABOVE FINISHED GRADE

DESIGNER OF RECORD

SD SMOKE DAMPER

EX EXPLOSION PROOF

VEWSD VERY EARLY WARNING SMOKE DETECTION

LH

NS

LIGHT HAZARD

NOT SPRINKLERED

ORDINARY HAZARDOH

* DESIGN AREA MUST BE THE LESSER OF THE DESIGN AREA INDICATED OR THE ENTIRE AREA OF THE SPACE PROTECTED.

FIRE SUPPRESSION SPRINKLER SYSTEM DESIGN CRITERIA

WATERFLOW TEST DATA

TEST DATE: 13 NOV 2015

STATIC PRESSURE 190 PSI

RESIDUAL PRESSURE: 115 PSI

DISCHARGE FLOW: 2,718 GPM

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

9/28/2022 4:06:49 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/30/2022

D3457500

FS001

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

Ap pr ov er

FI

R

E

SU

PP

R

ES

SI

O N

G

EN

ER

AL

N O

TE

S, S

YM

BO

LS

, A N

D

AB

BR

EV

IA

TI

O N

50ft

GENERAL NOTES

1. REFER TO FA001 FOR FIRE ALARM GENERAL NOTES, SYBMOLS, AND ABBREVIATIONS.

2. REFER TO ARCHITECTURAL REFLECTED CEILING PLANS FOR COORDINATION WITH LIGHTS,

MECHANICAL DIFFUSERS, AND CEILING GRID.

KEYNOTES

1. WATER MAIN SERVICE TO THE BUILDING

2. FIRE DEPARTMENT CONNECTION

3. FIRE HYDRANT

4. WATER MAIN

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

PLAN

NORTH

9/28/2022 4:06:49 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/26/22

D3457500

FS002

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

Ap pr ov er

FI

R

E

SU

PP

R

ES

SI

O N

S

IT

E

PL

AN

12" = 1'-0"D3 FIRE SUPPRESSION SITE PLAN

WH

D W

R

EF

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:15

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:15

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:1 5

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

0-6 0 E

LE

CTR

O

NI

C

VIT

AL

SI

G

NS

M O

BI

LE

STA

ND

A .V

2/

1/2

S

CAL

E:

.5

:1 5

EQ

SP

ACE

22.0000

3.2428

7.9990

.1325

2.8200

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4

3.6

B'

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

MECH.

OFFICE

OFFICE

OFFICE

OFFICE

STO.

OPEN OFFICE

OFFICE

CORRIDOR

CORRIDOR

OPEN OFFICE

OPEN OFFICE

OFFICE

DENTAL EXAM.

DENTAL EXAM.

OPEN OFFICE

EXAM RM.

OFFICE

WAITING

OFFICE

EQUIP.

LAB STOR BIO

ENV

CLINICAL LAB

M. TOILET

PHARMACY

F. TOILET

STORAGE

M. SHOWER

J. CLO.

F. SHOWER

COMM.

ELECT.

FA CLO.

VESTIBULE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

OPEN OFFICE

152 CONFERENCE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

BREAK RM.

SIM RM.

STORAGE

OFFICE

CORRIDOR

CLASSROOM

OH

OH

OH

OH

OH

D1

FS501

D2

FS501

GENERAL NOTES

1. REFER TO FS001 FOR FIRE SUPPRESSION GENERAL NOTES, SYBMOLS, AND ABBREVIATIONS.

2. ALL AREAS MUST BE DESIGNED FOR LIGHT HAZARD, UNLESS OTHERWISE NOTED.

3. PROVIDE PIPING, RISERS, VALVES, AND SPRINKLERS THROUGHOUT. ALL AREAS MUST BE

DESIGNED AND INSTALLED IN ACCORDANCE WITH NFPA 13 AND UFC 3-600-01.

KEYNOTES

1. WET-PIPE SPRINKLER SYSTEM WITH SUPERVISED CONTROL VALVE, CHECK VALVE, FLOW

SWITCH, AND DRAIN/TEST CONNECTION. PIPE DRAIN/TEST CONNECTION TO BUILIDING EXTERIOR.

2. FIRE DEPARTMENT CONNECTION

3. FIRE PROTECTION SYSTEM RISER DRAIN

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

Pr oj ec t T itl e:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

H

EA

D Q

U A

R

TE

R S

-1

A

M

ED

. C

LI

N

IC

B

R

EN

O

VA

TI

O

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/28/2022 4:07:03 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/30/2022

D3457500

FS101

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

Ap pr ov er

FI

R

E

SU

PP

R

ES

SI

O N

F

LO

O R

P

LA

N

1/8" = 1'-0"D1 FIRE SUPPRESSION FLOOR PLAN

0 4' 8' 16'

C-CLAMP

WITH LOCKNUT

PIPE RING

ALL THREAD ROD

STRUCTURAL

MEMBER

THREADED

REDUCING

COUPLING

RECESSED SPRINKLER WITH WHITE

OR CHROME

ESCUTCHEON

SUSPENDED CEILING

WET PIPE SPRINKLER

SYSTEM BRANCH LINE

LEVEL 01

0' - 0"

T. JOIST

12' - 9"

T. JOIST

12' - 9"

D2

FS501

FIRE DEPARTMENT

CONNECTION

SYSTEM DRAIN

CONNECT TO EXISTING

HIGH PRESSURE MAIN

LEVEL 01

0' - 0"

T. JOIST

12' - 9"

T. JOIST

12' - 9"

LEVEL 01

0' - 0"

T. JOIST

12' - 9"

ABAA

D1

FS501

CHECK

VALVE

WATERFLOW

INDICATOR

RISER CHECK

VALVE

CONTROL VALVE

WITH TAMPER

SWITCH

SYSTEM

DRAIN

PIPE TO FIRE

DEPARMENT

CONNECTION

LEVEL 01

0' - 0"

T. JOIST

12' - 9"

AB

T. JOIST

12' - 9"

A

CONNECT TO EXISTING

HIGH PRESSURE MAIN

FLANGE

AND

SPIGOT

PIECE

ESCUTCHEON AT

EXPOSED LOCATIONS

PROVIDE WATERPROOF

SEALANT AROUND FLOOR

PENETRATION. BUILDING

FLOOR

TO FIRE PROTECTION

SYSTEMS

THRUST BLOCK

60"

CORE DRILL

BY SITE UTILITY

CONTRACTOR

BY FIRE

PROTECTION

CONTRACTOR

PIPE REDUCER

4" RISER

6-INCH SINGLE PIECE STAINLESS STEEL

FIRE

DEPARTMENT

CONNECTION

TO BUILDING

SPRINKLERS

FIRE WATER

CONNECTION FROM

EXISTING HIGH

PRESSURE WATER

MAIN

FS

DR

CONTROL

VALVE WITH

TAMPER

SWITCH

RISER CHECK

VALVE

WATERFLOW

INDICATOR

SYSTEM DRAIN

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g Ti tle

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

Ja co bs

E ng in ee rin g

G ro up In c.

A

LL

R

IG

H

TS

R

ES

ER

V

ED

D

SG

N D

R C

H K

AP

VD

AP

VD

BY

R

EV

IS

IO

N

D

AT

E N

O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

TY

PE

B -3

F

IN

AL

D

ES

IG

N S

U

BM

IT

TA

L

SE

PT

EM

BE

R

0, 200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELIMINARY

NOT FOR CONSTRUCTION

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Jeffrey C. McLaughlin, PE State of Registration: FLORIDA Registration Number: 71830

9/28/2022 4:07:08 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_FPRO_V20.rvt

09/30/2022

D3457500

FS501

Em er ge nc y/ R ep ai r M ed ic al

T ra in in g Bu ild in g

B

JC

M

D

PF

JA

B

Ap pr ov er

FI

R

E

SU

PP

R

ES

SI

O N

D

ET

AI

LS

NTSC4 BEAM CLAMP HANGER DETAIL

NTSB1 TYPICAL RETURN BEND

1/2" = 1'-0"D1 FIRE SUPPRESSION RISER SECTION

1/2" = 1'-0"D2 FIRE SUPPRESSION RISER SECTION 2

NTSD4 FIRE WATER SERVICE DETAIL

0 1' 2' 4'

NTSB3 FIRE PROTECTION RISER DIAGRAM

LEGEND

PIPING SYMBOLS

GENERAL NOTES

EXISTING TO REMAIN.

EXISTING TO BE REMOVED

NEW EQUIPMENT

EQUIPMENT CLEARANCE

EQUIPMENT SYMBOLS

PITCH DOWN IN DIRECTION OF ARROW

DIRECTION OF FLOW

BRANCH - TOP CONNECTION

BRANCH - SIDE CONNECTION

CONCENTRIC REDUCER

RISER UP (ELBOW)

CAPPED PIPE

BRANCH - BOTTOM CONNECTION

RISE OR DROP IN PIPE

RISER DOWN (ELBOW)

PUMP

LINE/WALL CLEANOUT

PIPING TYPES

A.

B.

C.

D.

E.

F.

G.

H.

J.

K.

L.

M.

N.

P.

Q.

R.

S.

REFER TO SPECIFICATIONS FOR MATERIALS AND METHODS FOR CONSTRUCTION.

COORDINATE THE EXACT LOCATION OF FLOOR DRAINS WITH THE ARCHITECTURAL DRAWINGS AND

MECHANICAL EQUIPMENT LOCATIONS PRIOR TO INSTALLATION OF DRAINS. PROVIDE A RADIUS

AROUND THE FLOOR DRAIN THAT SLOPES TOWARD THE FLOOR DRAIN FROM THE FINISHED FLOOR ELEVATION TO A TOP OF DRAIN ELEVATION BETWEEN 1/2" AND 3/4" BELOW FINISHED FLOOR, UNLESS OTHERWISE NOTED ON THE DRAWINGS. THE RADIUS AND RATE OF SLOPE IS TO BE FIELD

COORDINATED.

FURNISH ACCESS DOORS FOR INSTALLATION IN WALLS AND CEILINGS WHERE ACCESS IS REQUIRED

TO CONCEALED PLUMBING EQUIPMENT, VALVES, CONTROLS, AND OTHER DEVICES.

PERFORM WORK IN ACCORDANCE WITH THE LATEST EDITIONS, REVISIONS, AMENDMENTS OR

SUPPLEMENTS OF APPLICABLE STATUTES, ORDINANCES, CODES, OR REGULATIONS OF FEDERAL, STATE AND LOCAL AUTHORITIES HAVING JURISDICTION IN EFFECT ON THE DATE BIDS ARE

RECEIVED.

WHERE APPROVAL CODES HAVE BEEN ESTABLISHED BY OSHA, UNDERWRITERS LABORATORY,

AMERICAN CODES, ANSI, ASME, ASPE, ASA, ASSE, ASHRAE, ASTM, ARI, NEC, NFPA, SMACNA, OR THE

STATE FIRE INSURANCE REGULATORY BODY, FOLLOW THESE STANDARDS WHETHER OR NOT

INDICATED ON THE DRAWINGS.

COORDINATE WORK WITH ARCHITECTURAL FEATURES AND COORDINATE WORK SUCH THAT

INTERFERENCES BETWEEN PIPING, DUCTWORK, EQUIPMENT, HVAC WORK, FIRE PROTECTION

WORK, ELECTRICAL WORK, AND BUILDING STRUCTURE WILL BE AVOIDED.

PROVIDE THE ENTIRE SYSTEM AND ITS COMPONENT ITEMS OF EQUIPMENT IN OPERATING

CONDITION WITHOUT OBJECTIONABLE VIBRATION OR NOISE. PROVIDE WATER HAMMER ARRESTORS AT RESTROOM PLUMBING CHASES. NOISE LEVELS IN OFFICES SHALL BE MAINTAINED AT OR BELOW

NC35.

PROVIDE ALL WIRING AND ELECTRICAL CONTROLS IN ACCORDANCE WITH NFPA 70 (NEC).

VERIFY AND DOCUMENT EXISTING CONDITIONS AND DIMENSIONS ON THE JOB SITE PRIOR TO

STARTING ANY WORK.

DO NOT SCALE THESE DRAWINGS FOR CONSTRUCTION PURPOSES.

INSTALL PIPING TO PROVIDE THE MAXIMUM POSSIBLE CLEAR HEIGHT UNDERNEATH. MAINTAIN A

MINIMUM OF 6" ABOVE FINISHED CEILING TO PROVIDE CLEARANCE FOR LIGHTING FIXTURES.

CONTRACTOR TO MAKE ALL FINAL CONNECTIONS TO EQUIPMENT, INCLUDING OWNVER FURNISHED.

VENT TERMINALS SHALL EXTEND A MINIMUM OF 12" ABOVE THE FINISHED ROOF AND SHALL BE LOCATED A MINIMUM OF 10 FEET HORIZONTALLY FROM ANY DOOR, OPERABLE WINDOW, OR OTHER AIR INTAKE OF THE BUILDING OR ADJACENT BUILDING UNLESS THE VENT TERMINAL IS AT LEAST 2

FEET ABOVE THE TOP OF SUCH OPENING.

ALL VENT LINES ARE TO RISE VERTICALLY (45 DEG. ANGLE OR GREATER FROM HORIZONTAL) TO MINIMUM OF 6" ABOVE THE HIGHEST FLOOD LEVEL RIM OF THE HIGHEST FIXTURE SERVED BY VENT.

UTILITIES LOCATED BELOW GROUND AND EXTERIOR OF THE BUILDING SHALL BE INSTALLED A

MINIMUM OF 12" BELOW FROST DEPTH.

SEAL PENETRATIONS OF FIRE- AND/OR SMOKE-RATED CONSTRUCTION WITH U.L. APPROVED

STOPPING MATERIAL TO RESTORE THE ORIGINAL RATING OF THE PENETRATED CONSTRUCTION.

SEAL PENETRATIONS OF NON-RATED PARTITIONS WITH APPROVED MATERIAL TO PREVENT

AIRFLOW AND DEBRIS.

DRAWING/DETAIL REFERENCE KEY

RE : A2 / P-201

REFER TO

DRAWING/DETAIL

NUMBER

SHEET NUMBER ON

WHICH DETAIL IS

DRAWN

A2 P-201

SANITARY SEWER

SANITARY VENT (V)

DOMESTIC COLD WATER

DOMESTIC HOT WATER

DOMESTIC HOT WATER RETURN

COMPRESSED AIR

NATURAL GAS

CONDENSATE DRAIN

TEPID WATER SUPPLY

NON POTABLE WATER

TRAP PRIMER

SS

DHW

TW

TP

NG

CD

CA

NPW

X "X" DENOTES:

A - COMPRESSED AIR DROP

B - BREATHABLE AIR DROP

P

CLEANOUT

HOSE BIBB, WALL HYDRANT

FLOOR DRAIN, FLOOR SINK

P-TRAP

PLUMBING FIXTURES AND EQUIPMENT

METER

BACKFLOW PREVENTER

RISER DESIGNATION DENOTING

ASSOCIATED SANITARY OR

DOMESTIC WATER RISER DIAGRAM

AIR OUTLET VALVE

KEYNOTE REFERENCE

POINT OF CONNECTION

TO EXISTING

WATER HAMMER ARRESTOR

FUEL OIL RETURN

STORM DRAINSD

OD OVERFLOW DRAIN

FOS

FOR

FUEL OIL SUPPLY

WATER SERVICE FLOW TEST DATA

THE WATER LOAD IS 74 WSFU WHICH EQUATES TO 56 GPM WITH AN ADDITIONAL 3 GPM FOR HOSE BIBBS AND EQUIPMENT LEAKAGE AND 5 GPM FOR EMERGENCY FIXTURES: TOTALING 64 GPM DEMAND.

VALVE SYMBOLS

CHECK VALVE (NON SLAM)

PLUG VALVE

GLOBE VALVE

GATE VALVE

PRESSURE REDUCING VALVE (PRV)

BALL VALVE

BUTTERFLY VALVE

VENTURI FLOW METER

NEEDLE VALVE

VALVE IN DROP

VALVE IN RISE

VALVE IN CENTER DROP

GATE VALVE W/ 3/4" HOSE

THREAD ADAPTER

TWO-WAY CONTROL VALVE

THREE-WAY CONTROL VALVE

SOLENOID VALVE

SAFETY VALVE OR

PRESSURE RELIEF VALVE

MANUAL BALANCING VALVE

AUTOMATIC BALANCING VALVE

TEMPERATURE WELL

FLANGED VALVE

(GATE VALVE SHOWN)

FS

PS

PIPE GUIDE

PIPE ANCHOR

BLIND FLANGE

PRESSURE GAGE WITH COCK

UNION (SCREWED)

ORIFICE UNION

FLANGED CONNECTION

STRAINER WITH BLOWDOWN VALVE

TEMPERATURE & PRESSURE PORT

THERMOMETER

FLOW SWITCH

FLEX CONNECTION

FLEX PIPE

PRESSURE SWITCH

X

DESIGN CRITERIA

STORM DRAINAGE DATA (EXISTING TO REMAIN)

THE PRIMARY AND SECONDARY STORM DRAINAGE SYSTEMS ARE EXISTING TO REMAIN. REFER TO

ARCHITECTURE FOR GUTTER AND DOWNSPOUT LOCATIONS.

NATURAL GAS DATA

NATURAL GAS IS NOT AVAILABLE TO OUR KNOWLEDGE AND IS NOT PART OF THE DESIGN.

SANITARY DRAINAGE

X=W FOR WATER, X=G FOR GAS

POINT OF DISCONNECTION

FROM EXISTING

FLANGED ORIFICE

TEPID WATER RETURNTR

DHWR

DCW

V

NOTES

THE PLUMBING SYSTEM IS DESIGNED IN COMPLIANCE WITH ASHRAE 90.1-2013, ASHRAE 189.1-2014 AND

UFC 1-200-02 HIGH PERFORMANCE AND SUSTAINABLE BUILDING REQUIREMENTS.

ENERGY CODE COMPLIANCE

PUMP DISCHARGEPD

INDUSTRIAL WASTEIW

COMBINATION WASTE AND VENT SV

SUBSOIL DRAIN SSD

THE PLUMBING SYSTEMS ARE DESIGNED IN COMPLIANCE WITH 2018 INTERNATIONAL PLUMBING CODE

AS MODIFIED BY UFC 3-420-01 PLUMBING SYSTEMS.

PLUMBING CODE COMPLIANCE

BREATHABLE AIRBA

DRAWING ABBREVIATIONS

A______________________________________________________

ABV ABOVE

ADJ ADJUSTABLE

AFC ABOVE FINISHED CEILING

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AHU AIR HANDLING UNIT

ANSI AMERICAN NATIONAL STANDARD INSTITUTE

ARCH ARCHITECT, ARCHITECTURAL

ARI AIR CONDITIONING & REFRIG. INSTITUTE

ASHRAE AMERICAN SOCIETY OF HEATING, REFRIG.

AND AIR CONDITIONING ENGINEERS

ASME AMERICAN SOCIETY OF MECHANICAL ENGINEERS

ASPE AMERICAN SOCIETY OF PLUMBING ENGINEERS

ASTM AMERICAN SOCIETY OF TESTING AND MATERIALS

B______________________________________________________

BFF BELOW FINISHED FLOOR

BFP BACKFLOW PREVENTER

BLDG BUILDING

BOP BOTTOM OF PIPE

BOS BOTTOM OF STRUCTURE

C______________________________________________________

CFH CUBIC FEET PER HOUR

CIRC CIRCULATING

CLG CEILING

CO CLEANOUT

D______________________________________________________

DCBFP DOUBLE CHECK BACKFLOW PREVENTER

DCO DOUBLE CLEANOUT

DCW DOMESTIC COLD WATER

DHW DOMESTIC HOT WATER

D.I. DUCTILE IRON

DN DOWN

DWG DRAWING

E______________________________________________________

EEWS EMERGENCY EYEWASH SHOWER

ELEC ELECTRICAL

ET EXPANSION TANK

EWC ELECTRIC WATER COOLER

F______________________________________________________

FA FROM ABOVE

FB FROM BELOW

FCO FLOOR CLEANOUT

FLA FULL LOAD AMPS

FS FLOW SWITCH

G______________________________________________________

GPM GALLONS PER MINUTE

H______________________________________________________

HB HOSE BIBB

HTG HEATING

I______________________________________________________

IE INVERT ELEVATION

IEEE INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS

IN WC INCHES OF WATER COLUMN

IN WG INCHES OF WATER GAUGE

IW INDUSTRIAL WASTE

J______________________________________________________

JT JOINT

K______________________________________________________

K CONDUCTIVITY (BT/SF/1" THICKNESS)

KW KILOWATT

KWH KILOWATT-HOUR

L______________________________________________________

L LAVATORY

M______________________________________________________

MECH MECHANICAL

MFGR MANUFACTURER

MS MOP SINK

N______________________________________________________

NC NOISE CRITERIA, NORMALLY CLOSED

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MFGR'S ASSOC.

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NFWH NONFREEZE WALL HYDRANT

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

O______________________________________________________

OA OUTDOOR AIR

OLI OPTIONAL LINE ITEM

OSHA OCCUPATIONAL SAFETY AND HEALTH ADMIN.

OWS OIL / WATER SEPARATOR

P______________________________________________________

PBP PRIMARY BOOSTER PUMP

PD PRESSURE DROP

PLBG PLUMBING

PROVIDE FURNISH AND INSTALL

Q______________________________________________________

QTY QUANTITY

R______________________________________________________

RA RETURN AIR

RE: REFERENCE, REFER

REQD REQUIRED

REV REVISION, REVISE

RCP RECIRCULATION PUMP

RTN RETURN

S______________________________________________________

S SINK

SD STORM DRAIN

SA SUPPLY AIR

SPEC SPECIFICATION

SS SANITARY SEWER

S (CONTINUED)______________________________________

ST STORAGE TANK

STD STANDARD

T__________________________________________________

TD TRENCH DRAIN

TMV THERMOSTATIC MIXING VALVE

TYP TYPICAL

U__________________________________________________

U URINAL

UF UNDERFLOOR

UL UNDERWRITERS LABORATORIES, INC.

U.N.O. UNLESS NOTED OTHERWISE

V___________________________________________________

V VENT

VERT VERTICAL

VTR VENT THROUGH ROOF

W___________________________________________________

WB WALL BOX

WC WATER CLOSET

WCO WALL CLEANOUT

WH WATER HEATER

DOMESTIC HOT WATER DATA

DOMESTIC HOT WATER DESIGN BASED ON 63°F COLD WATER WITH 120°F DISCHARGE WATER

TEMPERATURE. CIRCULATE HOT WATER AT 120°F AND RETURN HOT WATER AT 105°F.

VACUUMVAC

ORIFICE FLOW PLATE

OS&Y VALVE

BELLOWS CONNECTION

(DOUBLE SPHERE NEOPRENE TYPE)

ECCENTRIC REDUCER

s

ENGINE OILEO

G GREASE

HYDRAULIC OILHO

ENGINE COOLANTEC

LIMIT OF DEMOLITION WORK

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELI

M

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Kelvin T. Chang, PE State of Registration: FLORIDA Registration Number: 85410

9/27/2022 3:41:12 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_PLUM_V20.rvt

09/30/2022

D3457500

P-001

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

K C

H A

N G

K C

H A

N G

J S

T A

M P

E R

K C

H A

N G

G E

N E

R A

L N

O T E

S L E

G E

N D

S A

N D

A B

B R

E V

IA

T

IO

N S

NOTE: THIS IS A STANDARD LEGEND SHEET,

NOT ALL SYMBOLS MAY BE USED.

6" SS(E) 2" SS(D)

3" SS(E)

S

S (E

3" SS(D)

S

S (D

S

S (D

4" (D)

4" SS(D)

S

S (D

4" SS(D)

3" SS(D)

A. REFER TO SHEET P-001 FOR PLUMBING GENERAL NOTES, LEGENDS,

AND ABBREVIATIONS.

B. INVERT ELEVATIONS ARE FROM TOP OF ARCHITECTURAL FINISHED

FLOOR TO BOTTOM OF PIPE.

C. COORDINATE FLOOR SINK AND FLOOR DRAIN LOCATIONS WITH

EQUIPMENT TO BE INSTALLED.

D. SLOPE WASTE PIPING AT THE FOLLOWING SLOPES UNLESS

OTHERWISE INDICATED ON PLANS: SMALLER THAN 3" IN DIAMETER

AT 1/4" PER FOOT, 3" TO 6" IN DIAMETER AT 1/8" PER FOOT.

E. REFER TO P-500 SERIES FOR TYPICAL DETAILS.

F. REFER TO P-600 SERIES FOR EQUIPMENT SCHEDULES AND

CONNECTION SIZES.

G. REFER TO P-700 SERIES FOR ISOMETRICS AND ADDITIONAL PIPE

SIZES.

H. EXTERNAL WALL HYDRANT HEIGHT SHALL BE 2'-0" ABOVE GRADE.

COORDINATE WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS.

I. PROVIDE ACCESS PANELS FOR ALL VALVES, WATER HAMMER

ARRESTORS, AND COORDINATE LOCATION WITH ARCHITECT.

J. COORDINATE PIPING CONNECTIONS WITH ACTUAL INSTALLED

EQUIPMENT.

K. CONTRACTOR MUST FIELD VERIFY LOCATION OF EXISTING SANITARY

PIPING BELOW GROUND AND THE INVERT LOCATIONS AT THE NEW

TIE IN POINTS AS SHOWN PRIOR TO THE START OF ANY DEMOLITION.

CONTRACTOR SHALL NOTIFY ALL PARTIES CONCERNED SHOULD ANY

DEVIATIONS NEED TO OCCUR.

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

P ro je c t T it le

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELI

M

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Kelvin T. Chang, PE State of Registration: FLORIDA Registration Number: 85410

H E

A D

Q U

A R

T E

R S

A

M E

D C

L

IN

IC

B

R E

N O

V A

T

IO

N D

IN

IN

G

C

PLAN

NORTH

KEY PLAN - NEW

1" = 60'

9/27/2022 3:41:13 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_PLUM_V20.rvt

09/30/2022

D3457500

P-101

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

K C

H A

N G

K C

H A

N G

J S

T A

M P

E R

K C

H A

N G

L E

V E

L

P

L U

M B

IN

G

E

X

IS

T

IN

G /D

E M

O

1/8" = 1'-0"A1

LEVEL 1 - PLUMBING - EXISTING/DEMO

001 FIELD VERIFY LOCATION OF DRAIN PIPE SHOWN. CUT PIPE, CAP, AND ABANDON

UPSTREAM LINE IN PLACE. REFER TO ARCHITECTURAL PLANS FOR PATCHING.

PREPARE REMAINING DOWNSTREAM PIPE FOR NEW CONNECTION. REMOVE ALL

FIXTURES.

002 FIELD VERIFY LOCATION OF DRAIN PIPE SHOWN. REMOVE ALL FIXTURES ON

BRANCH AND ABANDON LINE IN PLACE. REMOVE ALL VENT LINES AND PATCH

FLOOR PENETRATIONS. REFER TO ARCHITECTURAL PLANS FOR PATCHING.

003 EXISTING 2-1/2" WATER LINE RISER WITH SHUTOFF. DEMOLISH LINES

DOWNSTREAM OF POINT ABOVE CEILING AND PREPARE EXISTING RISER FOR A

NEW CONNECTION.

004 PHOTO DOCUMENT DENTAL EQUIPMENT, FILTERS, REGULATORS, AND

ACCESSORIES AND UNINSTALL. STORE EQUIPMENT ON SITE FOR RELOCATION.

NOTE SYSTEM ORIENTATION AND REPLICATE CONNECTIONS WHEN

RELOCATING.

005 FIELD VERIFY LOCATION OF DENTAL CHASE PIPE SHOWN. CUT PIPE, CAP, AND

ABANDON LINE IN PLACE. REFER TO ARCHITECTURAL PLANS FOR PATCHING.

KEY NOTES - PLUMBING

GENERAL NOTES - PLUMBING

OPEN OFFICE

121DENTAL EXAM.

DENTAL EXAM.

OPEN OFFICE

OFFICE

LAB STOR BIO

ENV

EQUIP.

CLINICAL LAB

EXAM RM.

OFFICE

COMM.

ELECT.

MECH.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

WAITING

OPEN OFFICE

OFFICE

OPEN OFFFICE

FA CLO.

VESTIBULE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

OPEN OFFICE

CONFERENCE

CLASSROOM

SIM RM.

BREAK RM.

OFFICE

STORAGE

OPEN OFFICE

OFFICE

OFFICE

OFFICE

M. TOILET

PHARMACY

F. SHOWER

M. SHOWER

F. TOILET

J. CLO.

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

STO.

OPEN OFFICE

OFFICE

CORRIDOR

WC-1

S-2

WC-1

WC-1

EWC-1

WC-1

LAV-1

LAV-1

LAV-1

LAV-1

S-1 S-1 S-1 S-1 S-1

S-1

S-1

MS-1

2 1/2"ø CW

/2 "ø

C W

1 1/4"ø CW

/4

"ø H

W R

3/4"ø HW

1/2"ø CW

3/4"ø HW

"ø

H W

/2

"ø C

W

3/4"ø HW

1/2"ø CW

1"ø CW

1"ø HW

SH-1

SH-1

HYD-1

WB-1

CP-1

WH-1

ET-1

/2

"ø C

W

/2

"ø C

W

3/4"ø CW

S-3

EW-1

3/4"ø HWR3/4"ø CW

/4 "ø

C W

WM-1

WB-1

HYD-1

TMV-1

CIRCUIT-SETTER

BALANCING VALVE.

A. REFER TO SHEET P-001 FOR PLUMBING GENERAL NOTES, LEGENDS,

AND ABBREVIATIONS.

B. INVERT ELEVATIONS ARE FROM TOP OF ARCHITECTURAL FINISHED

FLOOR TO BOTTOM OF PIPE.

C. COORDINATE FLOOR SINK AND FLOOR DRAIN LOCATIONS WITH

EQUIPMENT TO BE INSTALLED.

D. SLOPE WASTE PIPING AT THE FOLLOWING SLOPES UNLESS

OTHERWISE INDICATED ON PLANS: SMALLER THAN 3" IN DIAMETER

AT 1/4" PER FOOT, 3" TO 6" IN DIAMETER AT 1/8" PER FOOT.

E. REFER TO P-500 SERIES FOR TYPICAL DETAILS.

F. REFER TO P-600 SERIES FOR EQUIPMENT SCHEDULES AND

CONNECTION SIZES.

G. REFER TO P-700 SERIES FOR ISOMETRICS AND ADDITIONAL PIPE

SIZES.

H. EXTERNAL WALL HYDRANT HEIGHT SHALL BE 2'-0" ABOVE GRADE.

COORDINATE WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS.

I. PROVIDE ACCESS PANELS FOR ALL VALVES, WATER HAMMER

ARRESTORS, AND COORDINATE LOCATION WITH ARCHITECT.

J. COORDINATE PIPING CONNECTIONS WITH ACTUAL INSTALLED

EQUIPMENT.

K. CONTRACTOR MUST FIELD VERIFY LOCATION OF EXISTING SANITARY

PIPING BELOW GROUND AND THE INVERT LOCATIONS AT THE NEW

TIE IN POINTS AS SHOWN PRIOR TO THE START OF ANY DEMOLITION.

CONTRACTOR SHALL NOTIFY ALL PARTIES CONCERNED SHOULD ANY

DEVIATIONS NEED TO OCCUR.

D

C

B

A

1 2 3 4 5 6

Date:

Proj. No.:

PLOT DATE/TIME:

www.Jacobs.com

Drawing No.:

D ra w in g T it le

REUSE OF DOCUMENTS: THIS DOCUMENT, AND THE IDEAS AND DESIGNS INCORPORATED HEREIN, AS AN INSTRUMENT OF PROFESSIONAL SERVICE, IS THE PROPERTY OF JACOBS AND IS NOT TO BE USED, IN WHOLE OR IN PART, FOR ANY OTHER PROJECT WITHOUT THE WRITTEN AUTHORIZATION OF JACOBS.

J a c o b s E n g in e e ri n g G ro u p I n c

A

L L R

IG

H

T S

R E

S E

R V

E D

D S

G N

D R

C H

K A

P V

D

A P

V D

B Y

R E

V

IS

IO

N

D A

T E

N O

125th FIGHTER WING

FLORIDA AIR NATIONAL GUARD

14300 Fang Road Jacksonville international airport, Florida 32218

Contract Number

LSGA112024

T Y

P E

B -3

F

IN

A L D

E S

IG

N

S U

B M

IT

T A

L

S

E P

T E

M B

E R

200 S. Orange Avenue, Suite 900 Orlando, Florida 32801

PH.: 407-903-5001

PRELI

M

IN

ARY

NO

T F

O R C

O

NSTRUCTIO

N

Florida Architectural Corporation License #AAC001790 Florida Engineering Certificate Authorization #2822

Kelvin T. Chang, PE State of Registration: FLORIDA Registration Number: 85410

PLAN

NORTH

9/27/2022 3:41:16 PM BIM 360://US FL_D3457500_FLANG_Emergency Repair Medical Training Facility Building 1002B/FLANG_BLDG1002B_PLUM_V20.rvt

09/30/2022

D3457500

P-201

E m e rg e n c y /R e p a ir M e d ic a l T ra in in g B u ild in g

B

K C

H A

N G

K C

H A

N G

J S

T A

M P

E R

K C

H A

N G

L E

V E

L

P

L U

M B

IN

G

D

O M

E S

T

IC

S U

P P

L Y

P L A

N

1/8" = 1'-0"A1

LEVEL 1 - PLUMBING - DOMESTIC SUPPLY

001 EXISTING 2-1/2" WATER LINE RISER WITH SHUTOFF. CONNECT TO EXISTING

RISER AT POINT DETERMINED ABOVE CEILING AND COORDINATE ACCESS WITH

ARCHITECTURAL PLANS.

002 REFER TO WATER HEATER DETAIL C1 ON SHEET P-502 FOR ROUTING AND

CONFIGURATION OF MIXING VALVE AND RECIRCULATION PUMP. ROUTE T&P

RELIEF LINE ALONG WALL AND TERMINATE 3" ABOVE MOP SINK.

003 PROVIDE WITH WASTE DISPOSAL WD-1. COORDINATE WITH ELECTRICAL PLANS

FOR POWER HOOKUP.

004 ROUTE WATER LINE TO RELOCATED DENTAL EQUIPMENT VIA NEW PVC CHASE.

REFER TO SANITARY PLAN FOR CONTINUATION.

005 PROVIDE AND INSTALL 2-1/2" DISPLACEMENT TYPE WATER METER WITH DIGITAL

READOUT AND TIED INTO THE BAS FOR ANG MONITORING.

P-204

KEY NOTES - PLUMBING

GENERAL NOTES - PLUMBING

A

B

C

D

1 2 3 4 5 6

CC

BB

AA

2.4 3.6

B'

OPEN OFFICE

DENTAL EXAM.

DENTAL EXAM.

OPEN OFFICE

OFFICE

EQUIP.

CLINICAL LAB

EXAM RM.

OFFICE

COMM.

ELECT.

MECH.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

EXAM RM.

WAITING

OPEN OFFICE

OFFICE

OPEN OFFFICE

FA CLO.

VESTIBULE

OFFICE

OFFICE

OFFICE

OPEN OFFICE

OPEN OFFICE

CONFERENCE

CLASSROOM

SIM RM.

BREAK RM.

OFFICE

STORAGE

OPEN OFFICE

OFFICE

OFFICE

OFFICE

M. TOILET

PHARMACY

F. SHOWER

M. SHOWER

F. TOILET

J. CLO.

STORAGE

OFFICE

OFFICE

OFFICE

OFFICE

STO.

OPEN OFFICE

OFFICE

CORRIDOR

WC-1

S-2

WC-1

WC-1

EWC-1

WC-1

LAV-1

LAV-1

LAV-1

MS-1

LAV-1

S-1S-1 S-1 S-1S-1

S-1

S-1

FD-1

FD-1

FD-1

FD-1

FD-1

3"ø SS3"ø SS

4"ø SS

4"ø SS

"ø

S S

2"ø SS

2"ø SS

"ø

S S

"ø

S S

3"ø SS

FCO-1

FCO-1

FD-2

FD-2

3"ø SS

S-3

EW-1

FD-1

4"ø SS

3" SS (E)

S

S E

S

S E

4" SS (E)6" SS (E)6" SS (E)

FD-1

3"ø P V C C

H A S E

3"ø PVC CHASE

3/4"ø CD

/4

"ø C

D

"ø

S S

"ø

S S

RELOCATED

AIR

COMPRESSOR

RELOCATED

WET VACUUM

FILTER/AIR

DRYER

2" DENTAL

VAC

WCO

A. REFER TO SHEET P-001 FOR PLUMBING GENERAL NOTES, LEGENDS,

AND ABBREVIATIONS.

B. INVERT ELEVATIONS ARE FROM TOP OF ARCHITECTURAL FINISHED

FLOOR TO BOTTOM OF PIPE.

C. COORDINATE FLOOR SINK AND FLOOR DRAIN LOCATIONS WITH

EQUIPMENT TO BE INSTALLED.

D. SLOPE WASTE PIPING AT THE FOLLOWING SLOPES UNLESS

OTHERWISE INDICATED ON PLANS: SMALLER THAN 3" IN DIAMETER

AT 1/4" PER FOOT, 3" TO 6" IN DIAMETER AT 1/8" PER FOOT.

E. REFER TO P-500 SERIES FOR TYPICAL DETAILS.

F. REFER TO P-600 SERIES FOR EQUIPMENT SCHEDULES AND

CONNECTION SIZES.

G. REFER TO P-700 SERIES FOR ISOMETRICS AND ADDITIONAL PIPE

SIZES.

H. EXTERNAL WALL HYDRANT HEIGHT SHALL BE 2'-0" ABOVE GRADE.

COORDINATE WITH STRUCTURAL AND ARCHITECTURAL DRAWINGS.

I. PROVIDE ACCESS PANELS FOR ALL…