About this file

This Break-Out Pricing Sheet is part of a Lakeland Electric Request for Proposal (RFP) Specification No. 2024-REQ-343 for Unit 5 Spring 2025 Outage Contractor Services. The solicitation seeks qualified boiler and Heat Recovery Steam Generator (HRSG) contractors to perform complex maintenance and repair work during a scheduled outage from February 22nd to May 5th, 2025. The pricing document requires bidders to provide detailed cost breakdowns for specific scope items, including high-pressure desuperheater pipe/liner replacement, HRSG floor liner replacement, expansion joint flow liners, high-pressure drum access doors, penetration seals, and tube segment replacements. Bidders must also provide per-item costs for different tube segment replacements with specific material specifications.

The pricing sheet includes comprehensive pricing sections that allow for both fixed-price and time-and-materials billing. Contractors must list labor rates for various classifications at both straight time and overtime rates, and provide a mechanism for billing materials and sub-contracted services at cost plus a percentage markup. The document requires bidders to list references from at least three comparable projects and provide details on all potential subcontractors. Additional pricing flexibility is built into the document, allowing for work outside the original scope to be billed with prior written owner approval, which suggests the potential for project scope modifications during the maintenance period.

View the file

Other files

File Type Posted
Unit_5_Spring_2025_Outage_Contractor_Services_(Addendum_#6_Revision).pdf PDF
ATTACH_26_25-1300-4080_Fabric_Expansion_Belt_for_10_inch_nozzle.pdf PDF
ATTACH_30_997003-CB-014_HP_Superheater_3_Middle_Lower_Gas_Baffles.pdf PDF
ATTACH_27_25-1300-4081_Fabric_Expansion_Belt_for_14_inch_Nozzle.pdf PDF
ATTACH_29_997003-CB-013_Reheater_2_Front_Lower_Gas_Baffles.pdf PDF
ATTACH_28_997002-CA-11_Fabric_Expansion_Belt_for_12_Inch_Nozzle_and_997002-CA-012_PAcking_Gland_for_16_inch_Nozzle.pdf PDF
ATTACH_31_997003-CB-015_HP_Superheater_2_Back_Lower_Gas_Baffles.pdf PDF
City_of_Lakeland_Terms_-_2024.docx DOCX document
2025-RFP-002_Mandatory_Pre-Bid_Attendance_List.pdf PDF
ATTACH_09_25-1300-4069_NE_Field_Joint_Details_at_Floor.pdf PDF
ATTACH_06_25-1300-4028_NE_Floor_Field_Seam_Liners.pdf PDF
ATTACH_15_25-1301-4022_HP_Remote_Steam_Drum_Internal_Davit_and_Details.pdf PDF
ATTACH_24_Bundle_Layout_Plan_View_Color.pdf PDF
ATTACH_17_25-1313-4121_NORFLEX_HRSG_Outlet_EJ.pdf PDF
ATTACH_02_25-1300-4003_-_HRSG_General_Arrangement_Left_Side.pdf PDF
ATTACH_14_25-1300-5031_NE_Nozzle_Penetrations_COLS_5_to_8_and_11_to_14.pdf PDF
ATTACH_20_997000_SH_E1_NEPIPINGDATA.pdf PDF
ATTACH_08_25-1300-4068_NE_Floor_Liner_Layout.pdf PDF
ATTACH_23_Bundle_Layout_Elevation_View_Color.pdf PDF
ATTACH_01_25-1300-4002_-_HRSG_General_Arrangement_Right_side.pdf PDF
ATTACH_19_25-1317-5060_NE_INTERCONNECT_PIPING_SH_2.pdf PDF
ATTACH_18_25-1317-5059_NE_INTERCONNECT_PIPING_SH_1.pdf PDF
ATTACH_05_25-1300-4027_NE_Wall_Field_Seam_Liners.pdf PDF
ATTACH_13_25-1300-4100_NE_HP_Evaporator_Floor_Panel_COLS_7_to_8.pdf PDF
ATTACH_07_25-1300-4064_NE_Plan_View.pdf PDF
ATTACH_16_25-1313-4120_NORFLEX_Stack_Inlet_EJ.pdf PDF
ATTACH_11_25-1300-4087_NE_HP_EVAP_Casing_Assembly_Diagram_COL_7_to_8.pdf PDF
ATTACH_03_25-1300-4005_NE_HRSG_Elevation_View_Right_Side.pdf PDF
ATTACH_12_25-1300-4099_NE__Reheater_#1_&_HPSH_#1_Floor_Panel_COLS_6_to_7.pdf PDF
ATTACH_10_25-1300-4072_NE_Field_Corner_Angles.pdf PDF
ATTACH_22_2020031140-GA-100_10-HPDSHSPOOL.pdf PDF
ATTACH_21_2020031140-GA-007_10-HPDSHSPOOL.pdf PDF
ATTACH_04_25-1300-4006_NE_HRSG_Plan_View.pdf PDF
Indemnification_2025_Contractor.doc DOC document
PSM_-_Contractor_Annual_Audit_Form.pdf PDF
Show all 35

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Specification No. 2024-REQ-343 Page 1 Pricing Sheet

BREAK-OUT PRICING SHEET

2024-REQ-343

Unit 5 Spring 2025 Outage Contractor Services

The items below must be filled out clearly and completely. Please be sure to have read the Specification and any Addenda thoroughly, and to address any questions through OpenGov before the Bid due date. Failure to complete this form as instructed may result in Bidders being evaluated as non-responsive

A. Total of Fixed Price Items Total firm price for fixed-price items of bid Specification named Unit 5 Spring 2025 Outage Contractor Services as listed in Section 2.4 of the Specification/Bid: include cost of mobilization/de-mobilization and Public Construction Bond

Written Out ________________________________________________________ Dollars

B. Break-Out Pricing

B.1 Total cost of the Public Construction Bond as required for this Bid:

B.2 Total cost to complete Specification item 2.6, High-Pressure Desuperheater “B” Pipe/Liner Replacement

B.3 Total cost to complete Specification item 2.7, HRSG “Box 1” Floor Liner Replacement

Specification No. 2024-REQ-343 Page 2 Pricing Sheet

B.4 Total cost to complete Specification item 2.8, HRSG Expansion Joint Flow Liners

B.5 Total cost to complete Specification item 2.9, HRSG High-Pressure Drum Access Doors

B.6 Total cost to complete Specification item 2.10.A, HRSG Penetration Seals (Reheater)

B.7 Total cost to complete Specification item 2.10.B, HRSG Penetration Seals (HP Evaporator)

B.8 Total cost to Mobilize / Demobilize

Specification No. 2024-REQ-343 Page 3 Pricing Sheet

B.9 Provide a “per-item” cost to remove a twenty-four-inch (24") HRSG tube segment and replace with new OWNER supplied tube stock of SA-213-T91, 1.75"OD X 0.105"MWT, including all phases of heat treatment and R-1 Report required activities

B.10 Provide a “per-item” cost to remove a twenty-four-inch (24") HRSG tube segment and replace with new OWNER supplied tube stock of SA-213-T91, 1.75"OD X 0.125"MWT, including all phases of heat treatment and R-1 Report required activities

B.11 Provide a “per-item” cost to remove a twenty-four-inch (24") HRSG tube segment and replace with new OWNER supplied tube stock of SA-213-T22, 1.75"OD X 0.110"MWT, including all phases of heat treatment and R-1 Report required activities

Materials, rentals and sub-contracted services over and above the specified scope of work shall be billed at Cost plus _____________________________ percent (%), and substantiated with paid invoices

Specification No. 2024-REQ-343 Page 4 Pricing Sheet

C. References

Please list a minimum of three (3) projects completed by your company of equal or greater size, scope, cost, and complexity as the project specified in Specification 2024-REQ-343.

This list shall be prepared specifically for this Bid submittal and should include the name of the Entity the work was completed for, and the name and contact information of a responsible person qualified to respond to questions regarding the work performed, its quality, costs, schedule, etc.

Prior successful accomplishment of such work will be a consideration when evaluating Bidder’s qualifications

Entity Name Contact Person Telephone

Specification No. 2024-REQ-343 Page 5 Pricing Sheet

D. Additional Services

A. Rates for Classification of Labor: These rates will only be applied to T&M work as well as work outside of the written scope of this Specification. Work billed at the below rates must be approved in writing by OWNER prior to commencement

Classification / Job Title Straight Time Overtime

$ ____________ /hr $ ____________ /hr

Specification No. 2024-REQ-343 Page 6 Pricing Sheet

B. Please list all Subcontractors:

Company Name Address & Telephone Type of Craft / Service