Atta 1-5 Drawings_Non-WorkPlanLCS_MECH.pdf
PDF 9 MB Posted
- Solicitation number
- W91QVN23R0026
View the file
Other files
| File | Type | Posted |
|---|---|---|
| CIC_W91QVN23R00XX.docx | DOCX document | |
| B08 W91QVN23R0026-0001.pdf | ||
| Combined QA.pdf | ||
| Atta 3 OfferBreakdownFormat_Redacted.pdf | ||
| Atta 3 OfferBreakdownFormat.pdf | ||
| Atta 1-6 Drawings_Non-WorkPlanLCS_TITLE.pdf | ||
| B08 W91QVN23R0026.pdf | ||
| Atta 1-8 WarrantyList_Non-WorkPlanLCS_MECH.xlsx | XLSX spreadsheet | |
| Atta 1-3 Drawings_Non-WorkPlanLCS_ARCH.pdf | ||
| Atta 1-2 Drawings_Non-WorkPlanLCS_CIVIL.pdf | ||
| Atta 2-3 Appendix_WorkPlanLCSOMA.docx | DOCX document | |
| Atta 2-1 SOW_WorkPlanLCSOMA.docx | DOCX document | |
| Atta 2-2 Drawings_WorkPlanLCSOMA.pdf | ||
| Atta 1-4 Drawings_Non-WorkPlanLCS_ELEC.pdf | ||
| Atta 1-1 SOW_Non-WorkPlanLCS.docx | DOCX document | |
| Atta 1-7 WarrantyList_Non-WorkPlanLCS_ELEC.xlsx | XLSX spreadsheet | |
| Atta 1-9 WarrantyList_Non-WorkPlanLCS_ARCH.xlsx | XLSX spreadsheet |
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
M-1
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
o
ACCU AIR COOLED CONDENSING UNIT
ACLD AIR COOLED
ACU AIR CONDITION UNIT (S)
ACV ALARM CHECK VALVE
ADP APPARATUS DEW POINT
AHU AIR HANDLING UNIT
AIR COND AIR CONDITION (-ING,-ED)
AL ALUMINUM
ALT ALTITUDE
AMB AMBIENT
AMP AMPERE(AMP, AMPS)
APPROX APPROXIMATE
AVG AVERAGE
AWG AMERICAN WIRE GAUGE
BARO BAROMETER(-TRIC)
BARO PR PRESSURE, BAROMETRIC
BHP BRAKE HORSEPOWER
BP BOILING POINT
CAP CAPACITY
CCW COUNTER CLOCKWISE
CHW CHILLED WATER
CKT CIRCUIT
CLASS CLASSIFICATION
CLG LOAD COOLING LOAD
COEF COEFFICIENT
CONN CONNECTION
CONT
C
CMH CUBIC METER PER HOUR
CU M CUBIC METER
CENTIGRADE/ CELCIUS
CFCI
CONTRACTOR INSTALLED
CONTRACTOR FURNISHED
CIP CAST IRON PIPE
CWP
CU MM CUBIC MILLIMETER
Cv COEFFICIENT, VALVE FLOW
CW CLOCKWISE OR COLD WATER
CIRCULATING WATER PUMP
DB DECIBEL OR DRY BULB
COMPRESSORCPRSR
DBT DRY BULB TEMPERATURE
DCWS DOMESTIC COLD WATER SUPPLY
DEG or ° DEGREE
DFW DIESEL OIL
DOMESTIC HOT WATER RETURN
DOMESTIC HOT WATER SUPPLY
DHWR
DHWS
DIRECT EXPANSIONDX
DRY PIPE VALVEDPV
DOUBLE POLE DOUBLE THROWDPDT
DEWPOINT TEMPERATUREDPT
DIVISIONDIV
DIFFERENCEDIFF
DIAGRAMDIAG
DIAMETERDIA or
DWG DRAWING
EXPANSION JOINTEXPJT
ENTERING WATER TEMPEWT
EVAPORAT (-E,-ING,-ED,-OR)EVAP
EXTERNAL STATIC PRESSUREESP
EXPLOSION PROOFEP
EQUIPMENTEQPT
ENTERINGENT
EFFICIENCYEFF
EQUIVALENT DIRECT RADIATIONEDR
ECONOMIZERECON
ECCENTRICECC
ENTERING AIR TEMPERATUREEAT
FUEL OILFO
FA FACE AREA OR FRESH AIR
FHC FIRE HOSE CABINET
FHY FIRE HYDRANT
FLA FULL LOAD AMPERES
F FARENHEIT
FLR FLOOR
FEED WATER PUMPFWP
FACE VELOCITYFVEL
FLUSH VALVEFV
FRP
FREQUENCYFREQ
FEMALE PIPE THREADFPT
FIBERGLASS REINFORCED PLASTIC
Ft or ' FEET
FXTR FIXTURE
GALVANIZED STEELGALVS
GAGE OR GAUGEGA
GR GRAMS
GOVERNMENT INSTALLED
GOVERNMENT FURNISHED GFGI
CONTRACTOR INSTALLED
GOVERNMENT FURNISHEDGFCI
GAL GALLONS
GALLONS PER MINUTEGPM
HERTZHZ
HORIZONTALHORIZ
HOT WATER HEATERHWH
HOT WATERHW
HOUR(S)HR
HORSEPOWERHP
MERCURYHG
HEADHD
HB HOSE BIBB
DIAMETER, INSIDEID
ISOMETRICISO
IRON PIPE SIZEIPS
J JOULE
K THERMAL CONDUCTIVITY
K THERMAL CONDUCTIVITY
kG kCAL/HR
KILOGRAM
kG/SQ CM KILOGRAM PER SQ. CENTIMETER kG/SQ CM A
KILOCALORIE PER HOUR
(ABSOLUTE)
KILOGRAM PER SQ. CENTIMETER
kG/SQ CM G
(GAUGE)
KILOGRAM PER SQ. CENTIMETER
kG/SM KILOGRAM PER SQ. METER kG/SM A kG/SM G
(ABSOLUTE)
KILOGRAM PER SQ. METER
KILOGRAM PER SQ. METER (GAGE)
kW KILOWATT kWH KILOWATT HOUR kJ KILOJOULE kPa KILO PASCAL
LAT LEAVING AIR TEMPERATURE
LBS POUNDS
LG LENGTH
LH LATENT HEAT
LWT LEAVING WATER TEMPERATURE
LIQUID LINELL
L LITERS
LPD LITERS PER DAY
LPH LITERS PER HOUR
LPS
LM LINEAR METER
LITERS PER SECOND
LAV LAVATORY
LPM LITERS PER MINUTE
LT LAUNDRY TRAY
NUMBERNO
NORMALLY OPENN.O.
NOT IN CONTRACTNIC
NORMALLY CLOSEDN.C.
NOISE CRITERIANC
NCK
MAX
NOT TO SCALENTS
MIN
MPH
M METERS
MAXIMUM
MINIMUM OR MINUTE
METERS PER HOUR
MPS METERS PER SECOND
MM MILLIMETER
NPT NATIONAL TAPER PIPE (THREAD)
NOT APPLICABLEN/A
NECK
MECH MECHANICAL
OS&Y OUTSIDE SCREW & YOKE
OD
OAIL OUTSIDE AIR INTAKE LOUVER
OA OUTSIDE AIR
OUTSIDE DIAMETER
OPNG OPENING
OXY OXYGEN
PERCENT
PRESSURE REDUCING VALVEPRV
PARTS PER MILLIONPPM
POINT OF CONNECTIONPOC
PLUMBINGPLMB
PHASE (ELECTRIC)PH
PRESSURE GAGEPG
PD
POLEP
PRESSURE DROP OR DIFFERENCE
Pa PASCAL
POL PETROLEUM, OIL AND LUBRICANTS
QUANTITYQTY
QUARTQT
REFRIGERATION TONRT
REVOLUTIONS PER MINUTERPM
RADIATORRDTR
RETURN AIRRA
THERMAL RESISTANCER
REFRIGERANT (134A, 22, ETC)R134A,R22
RH RELATIVE HUMIDITY
SUPPLY AIRSA
SYMBOLSYM
SUCTIONSUCT
STORAGESTOR
STEELSTL
STANDARDSTD
STEAMST
SAYBOLT SECONDS UNIVERSALSSU
STAINLESS STEELSST
SAYBOLT SECONDS FUROLSSF
SQUARESQ
SPECIFICATIONSPEC
SINGLE POLE DOUBLE THROWSPDT
SM
LPH, STANDARD CONDITIONSSLPH
LPS, STANDARD CONDITIONSSLPS
SG
SLPD LPD, STANDARD CONDITIONS
SL SENSIBLE LOAD
SH SENSIBLE HEAT
SPECIFIC GRAVITY
SF SAFETY FACTOR
SEC SECOND
SCH SCHEDULE
STATIC PRESSURE
SQUARE METER
SP
SBM
SAN SANITARY
SUBMERSIBLE
TYPICALTYP
THERMOSTATTSTAT
TONS OF REFRIGERATIONTONS
THICKNESSTHK
THERMOMETERTHERM
TEMPERATURETEMP
TEMPERATURE DIFFERENCETD
UNIT HEATERUH
HEAT TRANSFER COEFFICIENTU
WTRPRF
WT
WSHR
WITHW/
WH
WIDTHWD
WCLD
WC
WBT
WB
WATTW
VP
VOL
VISC
VERTICALVERT
VENTILATIONVENT
VELOCITYVEL
VARIABLE AIR VOLUMEVAV
VAC VACUUM
VLV VALVE
V VOLT
WATERPROOF
WEIGHT
WASHER
WATTHOUR OR WATER HEATER
WATER-COOLED
WATER CLOSET
WET BULB TEMPERATURE
WET BULB
PRESSURE, DYNAMIC(VELOCITY)
VOLUME
VISCOSITY
VTR VENT THRU ROOF
UR URINAL
A B B R E V I A T I O N S
MECHANICAL MATERIAL INDICATIONS AND SYMBOLS
FS
VFM
OFM
AVA
PRESSURE RELIEF
TEMPERATURE
EXPANSION LOOP
EXPANSION JOINT
ANCHOR, INTERMEDIATE
ALIGNMENT GUIDE
AIR VENT, AUTOMATIC
SQUARE HEAD BALANCING COCK
QUICK OPENING
NEEDLE
LOCK SHIELD
FLEXIBLE CONNECTOR
FLOWMETER, ORIFICE
FLOWMETER, VENTURI
FLOW SWITCH
PRESSURE GAUGE AND COCK
STRAINER
THERMOMETER
PRESSURE REDUCING
RELIEF OR SAFETY
SLEEVE
BLOW OFF STRAINER
INLINE PUMP
SAFETY
FLOAT
valves, special duty
S
M
GATE, NORMALLY CLOSED
GLOBE
SOLENOID
3 WAY MANUAL
GATE, NORMALLY OPEN
PLUG
MOTOR OPERATED GATE
MOTOR OPERATED GLOBE
3 WAY ELECMOTOR CONTROL
3 WAY AIR MOTOR CONTROLLER
HOSE GATE
HOSE GLOBE
POST INDICATOR
OS Y
ANGLE GLOBE
ANGLE GATE
SWING GATE CHECK
S
M
P
M
M
ALARM CHECK
DRY PIPE
DELUGE
PREACTION
TAMPER DETECTION SWITCH
QUICK OPENING DEVICE
NON-RISING STEM
DIAPHRAGM
SOLENOID
MOTOR ELECTRIC
valve actuators
POTABLE COLD WATER
POTABLE HOT WATER
POTABLE HOT WATER RETURN
PIPE SLEEVE
BACKFLOW PREVENTER
PITCH OR PIPE, UP(U), DOWN(D)
VENT THRU ROOF
SURFACE CLEANOUT
FLOOR CLEANOUT
FLOOR DRAIN
PIPE SLEEVE WITH FIRE STOPPING
HOSE BIBB
FLOOR SINK (200mm x 200mm)
HOT WATER (60°C)
HOT WATER (82.22°C)
VENT
SANITARY SEWER
COMPRESSED AIR
FUEL OIL SUPPLY
FUEL OIL RETURN
FLOOR DRAIN WITH CLEANOUT
FLOOR DRAIN WITH DEEP TRAP
FLOOR DRAIN WITH NO TRAP
FLOOR DRAIN WITH TRAP TIME
FD
FCO
SCO
200x200
FIRE PROTECTION WATER SUPPLY
MAIN SUPPLY SPRINKLER
WET STANDPIPE
DRY STANDPIPE
COMBINATION STANDPIPE
plumbing sprinkler
DSP
WSP
CSP
S
F
PLAN ELEV
82.22°C
60°C
S
A
FOS
FOR
RD
RS
RL
D
CWS
CWR
LPC
BBD
PC
VPD
MU
FOD
FOV
FOG
FOS
FOR
HWS
M
HCS
HCR
FILL
MU
HWR
LOW PRESSURE CONDENSATE
BOILER BLOW DOWN
PUMPED CONDENSATE
VACUUM PUMP DISCHARGE
MAKE UP WATER
FUEL OIL DRAIN
FUEL OIL TANK VENT
FUEL OIL GAUGE
FUEL OIL SUPPLY
FUEL OIL RETURN
CONTROL AIR MAIN
DUAL TEMPERATURE RETURN
FILL LINE
MAKE UP WATER
DUAL TEMPERATURE SUPPLY
WATER SUPPLY
LOW TEMPERATURE HOT
WATER RETURN
LOW TEMPERATURE HOT
SPLITTER DAMPER
REFRIGERANT DISCHARGE
REFRIGERANT SUCTION
REFRIGERANT LIQUID
DRAIN
CHILLED WATER SUPPLY
CHILLED WATER RETURN
dampers piping heating air conditioning and refrigeration
DU 13mm
47.2
94.4
DG
300x150
500/300L
R
AD
FC
SG
SR
RG
RR
810mm x 400mm
810mm x 400mm
810mm x 400mm
EG
ER
810mm x 400mm
DIRECTION OF FLOW
FLEXIBLE CONNECTION
TRANSITION
(810mm WIDTH x 400mm DEPTH)
DUCT SIZES SHOWN
RISE(R), DOWN(D)
CHANGE OF ELEVATION
VERTICAL OR HORIZONTAL
ACCESS DOOR,
FIRST FIGURE IS ON TOP
POSITIVE PRESS.,
OUTSIDE AIR DUCT SECTION,
FIRST FIGURE IS ON TOP
POSITIVE PRESS.,
SUPPLY AIR DUCT SECTION,
FIRST FIGURE IS ON TOP
SECTION, NEGATIVE PRESS.,
RETURN OR EXHAUST AIR DUCT
SUPPLY OR RETURN
FLEXIBLE AIR DUCT,
TRANSITION
SQUARE TO ROUND
REGISTER, CEILING
EXHAUST AIR GRILLE OR
REGISTER, SIDEWALL
SUPPLY AIR GRILLE OR
REGISTER, CEILING
RETURN AIR GRILLE OR
OR REGISTER, CEILING
SUPPLY AIR MODULAR DIFFUSER
DOOR GRILLE (300mmx150mmH)
(500mmWx300mmH, 94.4 LPS)
LOUVER, DOOR OR WALL
(13mm, 47.2 LPS)
DOOR UNDERCUT
duct works grilles, registers and diffusers
LEGEND & ABBREVIATIONCONTINUE / CONTINUATION
fittings
TEE, SINGLE SWEEP
UNION, SCREWED
UNION, FLANGED
CONNECTION, TOP
ELBOW, 90°
ELBOW, TURNED UP
ELBOW, TURNED DOWN
TEE, OUTLET UP
TEE, OUTLET DOWN
CONNECTION, BOTTOM
REDUCER, CONCENTRIC
(STRAIGHT, INVERT)
REDUCER, ECCENTRIC
(STRAIGHT, DOWN)
REDUCER, ECCENTRIC
TEE
ELBOW, 45°
LATERAL
SOLVENT CEMENT
BELL AND SPIGOT
SCREWED
FLANGED
WELDED
SOLDERED/BRAZED
M
NS
BUTTERFLY
BALL
DIAPHRAGM
GATE
INDICATING BUTTERFLY
KEY OPERATED
CHECK
DELUGE VALVE
WALL MOUNTED TEST HEADER
FIRE ALARM BELL
HOSE STATION DRY STANDPIPE
MINI HORN
HORN SPEAKER
WALL HYDRANT 2 HOSE OUTLET
SMOKE DETECTOR
CUTTING POINT
CAP
NON-SPRINKLERED SPACE
RISER
CONNECTION (2-WAY SHOWN)
SIAMESE FIRE DEPARTMENT
CONNECTION
SINGLE FIRE DEPARTMENT
valves
UPRIGHT SPRINKLER (K=5.6)
SIDEWALL SPRINKLER (K=5.6)
UPRIGHT SPRINKLER (K=8.0)
PENDENT SPRINKLER (K=5.6)
PENDENT SPRINKLER (K=8.0)
RESIDENTIAL PENDENT SPRINKLER (K=4.9)
REPAIR BARRACKS
FIRE PROTECTION AND MECHANICAL GENERAL NOTES
A. REPAIR/MAINTENANCE (K-WORK)
SCOPE OF WORK
NOTE :
M-2
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG YONGSAN-CASEY
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
GENERAL NOTES & SCOPE OF WORK
LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.
24. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, AND THE
WITHIN 1M OF THE UNIT.
23. ALL CONDENSATE DRAINS FROM COOLING UNIT (AS NOTED ON THE DRAWINGS) SHALL BE PROVIDED WITH SHUT-OFF VALVE
FLUSHED IS CLEAR AS TAP WATER.
22. PIPING SYSTEM SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS AND FLUSHED UNTIL ALL WATER BEING
ALL ROUND DUCT TAKE-OFFS FROM SQUARE OR RECTANGULAR MAINS.
PROVIDE AIR SPLITTER DAMPERS AT ALL BRANCH TAKE-OFFS FROM THE MAIN DUCT. PROVIDE SPIN-IN TYPE FITTINGS AT
21. PROVIDE TURNING VANES IN ALL ELBOWS THAT CHANGE AIR DIRECTION MORE THAN 30 DEGREES OR USE RADIUS ELBOWS.
BODIES EXPOSED TO AIR BELOW THE FLOOR.
AIR CONDITIONING CONDENSATE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION, FROM SINK
20. INSTALL CONDENSATE DRAINS AT A MINIMUM SLOPE OF 1/4 INCH PER 1 FOOT. INSULATE ALL SEWER PIPING RECEIVING
PROVIDE REMOTELY ACTUATED DAMPERS IN AREA WITH GYPBOARD OR CONCEALED CEILINGS.
COORDINATE THE LOCATION OF ACCESS PANELS TO INSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.
AND FOR ANY ITEM INDISE DUCTS REQUIRING SERVICING OR INSPECTION 12"x12" ACCESS PANELS FOR TWO VALVES.
ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT SMOKE DETECTOR, BACKDRAFT DAMPERS
19. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, AND EQUIPMENT. PROVIDE ACCESS DOORS IN DUCTS AT
CALSS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.
18. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STATIC PRESSURE
TO THE COR FOR REVIEW AND APPROVAL.
MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB) REPORT SHALL BE SUBMITTED
WITH APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL SPECIFICATIONS FOR
17. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT ACCORDANCE
CONTRACTING OFFICER FOR APPROAL.
PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE
16. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL BE
DETAILS SHALL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK.
15. FOR O & MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT. THE
OFFICER.
14. THE CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY THE CONTRACTING
REPLACED BY THIS CONTRACTOR AT HIS OWN COST.
WORK, PIPING ETC. ANY DAMAGED DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED OR
13. CONNECTION TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE ANY EXISTING EQUIPMENT, DUCT
EQUIPMENT AND ELECTRICAL ITEMS.
TO THE GOVERNMENT, INCLUDING, BUT NOT LIMITED TO ITEMS SUCH AS WALLS, CEILING, ROOF, PIPE, DUCT, ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT NO ADDITIONAL COST
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS NECESSARY TO
PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AT HIS OWN COST.
11. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS
EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.
10. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, COMMENCING ANY CONSTRUCTION OR RENOVATION.
9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO
8. ALL VALVES ON WET PIPE SYSTEM SHALL MEET NFPA 13 REQUIREMENT.
7. INSTALL SYSTEM TEST CONNECTION ON WET PIPE SYSTEM AND SHALL BE LOCATED AT THE MOST REMOTE BRANCH LINE.
6. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED. PLUG TYPE TAMPER SWITCH SHALL NOT BE USED.
TO ALL RISER AND TRIM, SECTIONAL VALVES, INSPECTORS TEST VALVES, AND DRAINS.
5. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED" ON ALL VALVES INCLUDING AND NOT LIMITED
FLEXIBLE COUPLINGS, CLEARANCES, AND SEPARATION ASSEMBLIES.
PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". INCLUDING, BUT NOT LIMITED TO, SWAY BRACINGS,
4. PROVIDE ALL SEISMIC PROTECTION MEASURES FOR THE FIRE PROTECTION SYSTEM IAW NFPA 13 FOR "PROTECTION OF
PIPES LESS THAN 50 MM (2 INCHES) IN NOMINAL.
OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS ARE NOT REQUIRED ON SPRINKLER SYSTEM BRANCH LINES AND
CONFORMING TO ASME/ANSI A13. 1-1996, "SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS", INDICATING THE TYPE
3. MARK ALL EXPOSED INTERIOR PIPING AT 8 METER (26 FT) INTERVALS WITH PLASTIC WRAPAROUND TYPE PIPE LABELS
APPROVED FIRE STOPPING MATERIAL IAW SPECIFICATION 07 84 00.
2. THE CLEARANCES AROUND PIPE PENETRATION AT FIRE RATED WALLS AND/OR FLOOR SHALL BE PROPERLY SEALED WITH
UL LISTED AND/OR FM APPROVED IN ACCORDANCE WITH NFPA 13, NFPA 20 AND THE PROJECT SPECIFICATION.
COORDINATE SPRINKLER HEADS LOCATIONS WITH LIGHTING FIXTURES AND HVAC DEVICES. ALL EQUIPMENT SHALL BE
WITH APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS. THE CONTRACTOR SHALL
1. THE EQUIPMENT SHOWN ON THE PLAN ARE SUGGESTED LOCATIONS. FINAL LAYOUT SHALL BE VERIFIED AND IN ACCORDANCE
SWITCH WILL NOT BE IN EXCESS OF 61 METERS.
LEAST ONE SHUTOFF SWITCH PER FLOOR SO THAT THE TRAVEL DISTANCE TO THE NEAREST SHUTOFF
MOTORIZED DAMPER. LOCATION SHALL BE ADJACENT TO MANUAL FIRE ALARM PULL BOXES AND WITH AT
LABEL AS PER AT/FP REQUIREMENTS AND DISABLE THE FAN WHEN ACTIVATED AND CLOSE THE
9. THE BUILDING SHALL HAVE AN EMERGENCY SHUT DOWN SWITCH IN A CLEAR PLASTIC ENCLOSURE WITH
BY A LICENSED OR CERTIFIED INSTALLER.
8. INSTALLATION OF THE HVAC SYSTEM SHALL BE IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION
7. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.
CONDUITS AND ALL NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.
6. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, PROVIDE REMOTELY ACTUATED DAMPERS IN AREAS WITH GYPBOARD OR CONCEALED CEILINGS.
5. PROVIDE VOLUME DAMPERS ON DUCTWORK BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT.
UL LISTED.
DAMPER RATINGS SHALL BE COMPATIBLE WITH THE FIRE WALL OR FLOOR. FIRE DAMPERS SHALL BE
4. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS. FIRE
TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.
3. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER
THE CONTRACTING OFFICER.
2. THE CONTRACTOR SHALL SUBMIT MECHANICAL SYSTEM INSTALLATION SHOP DRAWINGS FOR APPROVAL BY
CLEARANCE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.
1. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE
TEST SHALL BE PERFORMED BY THE FPE (FIRE PROTECTION PROFESSIONAL ENGINEER).
7. THE CONTRACTOR SHALL INSPECT AND TEST THE FIRE PROTECTION SYSTEM. THE WORK INSPECTION AND
SYSTEM, SPARE SPRINKLER HEAD CABINET WITH SPARE SPRINKLER HEAD (6 EA) AS SHOWN ON DRAWINGS.
6. REPAIR THE SPRINKLER SYSTEM BY INSTALLING NEW AUTOMATIC FIRE PROTECTION WET SPRINKLER
CONTROL, ACCESS DOORS, AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON DRAWINGS.
HOT WATER CIRCULATING PUMP, ELECTRIC WATER COOLERS, VALVES, WATER HAMMER ARRESTERS, HEATER, DOMESTIC HOT WATER STORAGE TANK, DOMESTIC HOT WATER RECIRCULATION PUMP, DOMESTIC
SEWER AND VENT PIPING SYSTEM INCLUDING PLUMBING FIXTURES, WASHER BOX, DOMESTIC HOT WATER
5. REPAIR THE PLUMBING SYSTEM BY INSTALLING NEW DOMESTIC COLD AND HOT WATER PIPING SYSTEM, OPERATIONAL, SUCH AS EQUIPMENTS AND CONTROLS.
4. PERFORM COMMISSIONING AFTER CONSTRUCTION TO VERIFY THAT THE H.V.A.C SYSTEM IS FULLY
CONSTRUCTION TO VERIFY THAT THE HVAC SYSTEM WORKS PROPERLY.
3. PERFORM DALT (DUCT AIR LEAKAGE TEST) AND T.A.B (TESTING, ADJUSTING, AND BALANCING) AFTER
AND ALL ASSOCIATED ACCESSORIES FOR HVAC SYSTEM AS SHOWN ON DRAWINGS.
EMERGENCY HVAC SHUT-OFF SWITCH, DUCTS, PIPES, INSULATIONS, ACCESS DOORS, EQUIPMENT SUPPORT, PUMP UNIT, OUTSIDE AIR UNITS, RANGE HOOD, CONTROLS, DIFFUSERS, GRILLES, LOUVERS, DAMPERS,
2. REPAIR THE VENTILATION SYSTEM BY INSTALLING NEW EXHAUST FANS, OUTDOOR SPLIT SYSTEM HEAT
FOR HVAC SYSTEM AS SHOWN ON DRAWINGS.
CONTROLS, ACCESS DOORS, EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES
FINNED TUBE RADIATOR, UNIT HEATER, AIR SEPARATORS, DUCTS, PIPES, VALVES, INSULATIONS, AIR HANDLING UNITS, FAN COIL UNITS, SPLIT AIR CONDITIONING UNIT, EXPANSION TANKS, PUMPS,
1. REPAIR THE HEATING AND COOLING SYSTEM BY INSTALLING NEW WATER CHILLER, HOT WATER BOILER, ITEM NO
Q'TY SERVICE TYPE
1/3
E Q U I P M E N T S C H E D U L E S - 1
REMARKS
M-3
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
EQUIPMENT SCHEDULES - 1
NOTE :
REQUIRMENTS.
ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY,
HOT WATER BOILER
B
BUILDING
ENTIRE
FIRED FIRE-TUBE
PACKAGED OIL
(LPH)
FIRING RATE
22.7
(Kw)
GROSS INPUT
OIL BURNER MOTOR
HP VOLT/PH/HZ
115/1/60 82.2
(°C)
SUPPLY TEMP
(kPa)
WORKING PRESS
ITEM NO Q'TY TYPE
Q'TY VOLT/PH/HZ
REMARKS
WATER CHILLER
WATER CHILLER
AIR-COOLED
(TON)
CAPACITY
COOLING
GPM
(°C)
EWT
(°C)
LWT
COMPRESSORS
Q'TY VOLT/PH/HZPOWER
CONDENSER FAN
POWER
INPUT
WC
REFTRIGERANT
ITEM NO Q'TY SERVICE TYPE
EF
EF
EF
EF
EF
EXHAUST FANS
REMARKS
1 4
HP VOLT/PH/HZ
115/1/60
FAN MOTOR
115/1/60
115/1/60
1/15 115/1/60
1/12 115/1/60
RPM
1,550
1,550
62.3
62.3
74.7
ITEM NO Q'TY SERVICE TYPE
P
REMARKS
HP VOLT/PH/HZ
208/3/60
FAN MOTOR
115/1/60
208/3/60
RPM
PUMPS
CENTRIFUGAL TYPE
BASE MOUNTED END SUCTION
CENTRIFUGAL TYPE
PIPE MOUNTED IN-LINE
CENTRIFUGAL TYPE
PIPE MOUNTED IN-LINE
1,750
1,750
1,750
CONSTRUCTION
ALL BRONZE
CONSTRUCTION
ALL BRONZE
ITEM NO Q'TY SERVICE TYPE
ET
ET
EXPANSION TANK
BLADDER TYPE
BLADDER TYPE
REMARKS
(mm DIA x mm HEIGHT)
TANK SIZE
500 x 1,050
(LPS)
CAP.
198.2
141.5
(LPS)
CAP.
AIR
ITEM NO Q'TY
AS
AIR SEPARATOR
REMARKS
INLET OUTLET
SERVICE TYPE
PIPE MOUNTED
PIPE SIZE
80 DIA WITH STRAINER
23.6
CHILLED WATER SYSTEM
HOT WATER SYSTEM
208/3/60
CENTRIFUGAL TYPE
BASE MOUNTED END SUCTION
1,750
ET
30350 x 775
AS
PIPE MOUNTED WITH STRAINER
HOT WATER SYSTEM
CHILLED WATER SYSTEM
80 DIA
P
P
P
CIRC. PUMP
CHILLED WATER
CIRC. PUMP
DOMESTIC HOT WATER
RECIRC. PUMP
DOMESTIC HOT WATER
5.92
1.26
1.70
(kPa)
HEAD
185.4
44.8
134.5
1/4
1-1/2
(Pa)
ESP
1,550
45Watts
1/4
1/10
1 2 3
1 2 3
1 2 3 5
1 2 3
1 W/BACKDRAFT DAMPER 2 W/DISCONNECT SWITCH 3 BIRD SCREEN 4 CEILING GRILLE 5 PREFABRICATED ROOF CURB.
CIRC. PUMP
HOT WATER
W/VIBRATION ISOLATOR
VARIABLE FREQUENCY DRIVE
W/VIBRATION ISOLATOR
VARIABLE FREQUENCY DRIVE
FOR MECH ROOM
FOR LAUNDRY ROOM
124.5
DIAPHRAGM TYPE
80 DIA 80 DIA
ITEM NO Q'TY SERVICE TYPE
FAN COIL UNIT
FLOOR MTD. TYPE
VERTICAL CABINET
NOTE
HP VOLT/PH/HZ
115/1/60
115/1/60
115/1/60
(LPS)
CAPACITY
AIR
DB WB
COOLING COIL
LPS
(°C)
EWT
(kPa)
MAX WPD
HEATING COIL
(°C)
EAT
(°C)
EWT
82.2
FCU
FCU
FCU
EAT(°C)
16.9
SUPPLY FAN
292.6
FLOOR MTD. TYPE
VERTICAL CABINET
17.6
(Pa)
EPS
11.1
19.2
134.5
(Kw)
SENSIBLE
(Kw)
TOTAL
1.96 1.67
2.84
1.91
3.17
2.32
23.9
23.9
16.9
23.9
16.9
0.09
0.20
0.10
6.67
6.67
6.67
(KW)
HEAT CAP.
82.2
82.2
1/30
1/6
1/12193.5
1 115/1/602.7 0.76 23.9
16.9
0.02 6.67 0.32 20 82.2
FCU
-139.2
253.2 80%
2. MFR. "BURNHAM" MODEL OR APPROVED EQUAL.
1. BOILER FUEL BURNING EQUIPMENT SHALL BE COMPATIBLE WITH BOTH DFW & JP-8 FUELS.
EFFICIENCY
MIN.
208/3/60 R-410A
12 7 208/3/60 4 900W x 4
101.8 KW
32.4
32.4
86.4
86.4 4 4 900W x 4
ITEM NO
AHU
Q'TY SERVICE TYPE
LPS
HP VOLT/PH/HZ
MOTOR
AIR HANDLING UNIT
198.2
REMARKS
HEATING COILCOOLING COILSUPPLY FAN
EAT(°C)
DB WB
LAT(°C)
DB WB
14.4
LPS EWT(°C)
82.1
EAT(°C)
LAT(°C)
100%115/1/60
SETTING
O.A
(KW)
TOTAL
8.50 -15.530.5
26.1
15.3 0.19
(KW)
TOTAL
(KW)
SENSIBLE
6.72 2.66
TEMP (°C)
ENT.WATER
7.2
(Pa)
ESP
1/3
CEILING MOUNTED
CONCEALED HORIZONTAL
OUTSIDEAIR MAKE-UP
LANUDRY RM
2. MFR. "MAGIC AIRE" MODEL 24HBAW-4 OR APPROVED EQUAL.
1. COIL CAPACITY SHALL BE BASED ON THE COOLING REQUIREMENTS.
PURPOSE ROOM(114A)
BED ROOMS & MULTI
RM 103,110,111,112
315,415) & LOUNGE
MULTI PURPOSE RM(114B,
FLOOR MTD. TYPE
VERTICAL CABINET
FLOOR MTD. TYPE
VERTICAL CABINET
0.62
- 2.4
0.94
0.59
1/30
1 115/1/60
CP
2.2 124.1 1.7FLA
COMM. ROOM
ONLY 1ST FL
LIFT PUMP
CONDENSATE DRAIN
10.76 188
7.5
1,132.4
188.7
74.7
FOR BATH ROOM & JAN
FOR BATH ROOM
FOR TOILET
DIRECT DRIVEN, CENTRIFUGAL
IN-LINE DUCT MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL
ROOF MOUNTED TYPE,
DIRECT DRIVEN, CENTRIFUGAL
IN-LINE DUCT MOUNTED TYPE,
BELT DRIVEN, CENTRIFUGAL
IN-LINE DUCT MOUNTED TYPE,
DIRECT DRIVEN, W/HEAT LAMP
CEILING MOUNTED,
500 x 1,525
HOT WATER SYSTEM
DOMESTIC
(LITS)
VOLUME
ACCEPTANCE
(PSI)
PRESSURE
MAX. WORKING
=12 PSI
CHARGE PRESSURE
=12 PSI
CHARGE PRESSURE
8 115/1/6037.4 5.63 23.9
16.9
0.16 6.67 1.99 20 82.2
FCU
-236.0 5.33
MOUNTED TYPE
HORIZONTAL CEILING
1/3
CORRIDOR
1st,2nd,3rd & 4th FL.
C.O(116)
2. MFR. "LG ELEC" MODEL NO. ACAH033VETB & ACAH033VETB OR APPROVED EQUAL.
1. INVERTER SCROLL COMP., VIBRATION ISOLATOR, AHRI CERTIFIED & ETL LISTED, 3 YEARS WARRANTY.
6. 3 YEARS WARRANTY.
5. COIL CAPACITY SHALL BE BASED ON THE COOLING REQUIREMENTS.
4. W/ AIR DAMPER, W/ 20T FIBER GLASS FILTER.
ISOLATOR AS INDICATED ON DETAIL DWG.
3. EACH UNIT SHALL INCLUDE MANUFACTURER VALVE PACKAGE W/VIBRATION
2. UNIT SHALL BE PROVIDED WITH SUB-BASE AND COVER.
1. UL & AHRI 440 OR KC & KS B 6377 CERTIFIED PRODUCTS.
E Q U I P M E N T S C H E D U L E S - 2
ITEM NO Q'TY SERVICE TYPE
REMARKSVOLT/PH/HZ
NOTE :
REQUIRMENTS.
ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT
THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING
QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY,
ITEM NO Q'TY SERVICE TYPE
REMARKS
(LITS)
CAPACITY
TANK
DOMESTIC HOT WATER STORAGE TANK
ENTIRE BUILDING
HORIZONTAL TYPE
STEEL ROUND
(mmDIA x mmLONG )
TANK SIZE
1,650 x 3,475
CEMENT-LINED STEEL TANK, 150 PSI.
ASME CODE REQUIREMENTS COMPLETE,
7,570
208/1/60
M-4
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
EQUIPMENT SCHEDULES - 2
DT
ACU
COMM RM
AIR COOLED TYPE
PACKAGED SPLIT
(Kw)
CAPACITY
TOTAL
3.6 (1 TON)
(W)
POWER INPUT
1,150
2. ALL AC UNIT REFRIGERANT PIPING SHALL BE INSTALLED PERMANUFACTURER RECOMMENDATIONS.
1. EACH UNIT SHALL BE PROVIDED W/ WIRED REMOTE CONTROLLER.
ITEM NO Q'TY SERVICE TYPE
REMARKSVOLT/PH/HZ
208/3/6030,600
OUTDOOR SPLIT SYSTEM HEAT PUMP UNIT
OHPU
MULTI V TYPEALL OUTSIDE AIR UNITS
(BTU/HR)
CAPACITY
COOLING
TOTAL
(BTU/HR)
CAPACITY
HEATING
TOTAL
378,000
COMPRESSOR
HSS DC SCROLL x 4
(CFM)
FAN AIR FLOW
R-410A
REFTRIGERANT
1 2 3
1 COOLING CAPACITY SHALL BE BASED ON 35 DEG C 2 HEATING CAPACITY SHALL BE BASED ON 7 DEG C 3 MFR. "LG ELEC" MODEL NO. ARUN336BTE4 OR APPROVED EQUAL.
ITEM NO Q'TY SERVICE TYPE
REMARKSVOLT/PH/HZ
208/1/60 R-410A
REFTRIGERANT
1 COOLING CAPACITY SHALL BE BASED ON 35 DEG C 2 HEATING CAPACITY SHALL BE BASED ON 7 DEG C
OUTSIDE AIR UNIT
OAU
CEILING EMBEDDED TYPE
(BTU/HR)
CAPACITY
COOLING
(BTU/HR)
CAPACITY
HEATING
48,100 46,115
(CFM)
AIR FLOW RATE
(KW)
POWER INPUT
1 20.18
RATING
ELECTRICAL
336,000
180 AMP MOP
129 AMP MCA
SPLIT AIR CONDITIONING OUTDOOR & INDOOR UNIT
ITEM NO Q'TY SERVICE TYPE
REMARKS
(LITS)
CAPACITY
TANK
DOMESTIC HOT WATER HEATER
DWH
(°F)
RISE
TEMP.
100140
(°F)
TEMP.
SUPPLY
(LPH)
RECOVERY
HEAT
4,588
HP VOLT/PH/HZ
115/1/60
ELEMENT CAPACITY
1/3PACKAGED OIL FIRED TYPEDOMESTIC HOT WATER SYSTEM FUEL BURNING EQIPMENT SHALL BE COMPATIBLE WITH BOTH DFW & JP-8 MAX. WORKING PRESS. 150 PSI.
(LPH)
RATE
FIRING
33.7
ITEM NO Q'TY SERVICE TYPE
RH
REMARKS
1 2 32.5
VOLT/PH/HZ
115/1/60
FAN MOTOR
(CFM)
CAPACITY
FAN
RANGE HOOD
KITCHEN
HOOD VENTED TYPE
STAINLESS STEEL
AMPS
1 W/BACKDRAFT DAMPER 3 CHARCOL AND WASHABLE GREASE FILTER2 W/75 WATT LIGHTING
4 BUILT-IN CONTROL SWITCH.
(mm)
HOOD SIZE
750 X 500
ITEM NO Q'TY
ELECTRIC WATER COOLER
EWC
DESCRIPTION
SHALL CONFORM TO ADA/ARI STANDARD 1010.
REGULATOR W/BOTTLE FILLING STATION. MECHANICALLY AIR COOLED WITH AIR COOLED CONDENSER & COMPRESSOR
WALL MOUNTED TYPE, BUBBLER SHAL BE ACTIVATED BY DEPRESSING EITHER PUSH PADS AND BUILT-IN PRESSURE
MODEL
POWER
CAPACITY
: MFR. "ELKAY" MODEL LMABF8WS, OR APPROVED EQUAL.
: 4.0F.L.AMPS, 115 V, 1 PH, 60 HZ.
: 30.3 LPH, 32.2 DEC C TO 10 DEC C.
ITEM NO Q'TY SERVICE
REMARKS
FTR
82.2
(°C)
EWT
(LPS)
FLOW RATE
HOT WATER
(°C)
EAT
ROW
FINNED TUBE RADIATOR
0.02
ITEM NO Q'TY SERVICE TYPE
REMARKS
DISCHARGE TYPE
HORIZONTAL
VOLT/PH/HZ
FAN CAPACITY
LPS
256.2 1,550
RPM HP
1/20
UNIT HEATER
UH
LPS
10.0
(°C)
EWT
(°C)
EAT
0.05 82.1 115/1/60MECH RM (123)
(Kw)
CAPACITY
HEATING
2.3
STORAGE
(KW)
CAP.
HEATING
0.73 15.6
(mm)
LENGTH
ELEMENT
3 208/1/60 R-410A
OAU
CEILING EMBEDDED TYPE 95,900 91,360 1 20.362nd FL, 3rd FL AND 4th FL
708/477/4771st FL BED ROOM
1,260/837/837
4. 3 YEARS WARRANTY.
3. MFR. "LG ELEC" MODEL NO. SW09BAJWAS OR APPROVED EQUAL.
/ MFR. "LG ELEC" MODEL NO. ARNU483B8Z4 OR APPROVED EQUAL. 3 YEARS WARRANTY.
/ MFR. "LG ELEC" MODEL NO. ARNU963B8Z4 OR APPROVED EQUAL. 3 YEARS WARRANTY.
/ 3 YEARS WARRANTY.
- M5
1 EXISTING AND REMOVAL MECHANICAL PLAN
NOT TO SCALE
M-5
NTS
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
MECHANICAL PLAN
EXISTING AND REMOVAL
THIRD FLOOR
SECOND FLOOR
FIRST FLOOR
FOURTH FLOOR
UP
UP
D
D
D
W
W
UPDN
UPDN
REF
D
D
D
W
W
UPDN
UPDN
D
D
D
W
W
DN
DN
D
D
D
W
W
CONTROLS, EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES.
PIPES, VALVES, DIFFUSERS, GRILLES, LOUVERS, DAMPERS, INSULATIONS,
ELECTRIC WATER COOLERS, VALVES, WATER HAMMER ARRESTERS, DUCTS,
HOT WATER RECIRCULATION PUMP, DOMESTIC HOT WATER CIRCULATING PUMP,
HOT WATER HEATER, DOMESTIC HOT WATER STORAGE TANK, DOMESTIC
PIPING SYSTEM INCLUDING PLUMBING FIXTURES, WASHER BOX, DOMESTIC
DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER AND VENT
PUMPS, ELECTRIC HEATERS, UNIT HEATER, EXHAUST FANS, RANGE HOOD,
SPLIT AIR CONDITIONING UNIT, EXPANSION TANKS, AIR SEPARATOR,
AIR HANDLING UNITS, FAN COIL UNITS, FINNED TUBE RADIATOR,
REMOVE EXISTING DETERIORATED WATER CHILLER, HOT WATER BOILER,
SACLE = 1:100
M-6
GRAPHIC SCALE
SCALE: 1:100
0 2000 4000
NEW H.V.A.C PLAN (1st FLOOR) M6
C.O
STAIR-1
119A
LAUNDRY
VEST
MECH ROOM
MULTI-PURPOSE RM
114B
STORAGE
ROOM
SPRINKLER
MULTI-PURPOSE RM
114A
CORRIDOR
MALE
113A
COMMO SHOP
STORAGE
VEST
ROOM
COMMUNITY ADMIN OFFICE
NBC ROOM
SUPPLY ROOM
COMM
XO
CO
STORAGE
106C
STORAGE
105A
R.O
106B
T.O
106A
STAIR-2
119B
102B
BED ROOMBED ROOM
102A
BED ROOM
101B
BED ROOM
101A
,9
,6
,9
,4
61,169
11,557 3,784 7,620 7,620 7,620 7,620 4,878 3,327 3,204 3,939
C
H W
R
C
H W
S
D
C
H W
R
C
H W
S
D
C
H W
R
C
H W
S
D D
C
H W
R
C
H W
S
D
C
H W
R C
H W
S D
C
H W
R C
H W
S D
C
H W
R C
H W
S D
C
H W
R C
H W
S D
C
H W
R C
H W
S D
C
H W
R C
H W
S D D
D D D
D D D D DD
C
H W
S C
H W
R
T
T
T
T T T
C
H W
R
C
H W
S
D
C
H W
R
C
H W
S
D
C
H W
R
C
H W
S
D
C
H W
R
C
H W
S
D
C
H W
R
T
C
H W
R
C
H W
S
D D
JAN
COMM RM
WAIT AREA
FEMALE
113B
100100 40
UNIT NO.
EQUALIZING DEFLECTOR
S-1
FUNCTION TYPE TYPE REMARKSFINISHMATERIAL ACCESSORIES
1 2 3
AIR DEVICE SCHEDULE
S-2 REGISTER 1 4 7
R-1 REGISTER 1 4 5
E-1 EXHAUST REGISTER 1 4 5
E-2 EXHAUST 1 4 5
SUPPLY
SUPPLY
RETURN
GRILLE
4 6
WHITE ENAMEL
SQUARE DIFFUSER ALUMINUM
ALUMINUM
ALUMINUM
ALUMINUM
ALUMINUM
OPPESED BLADE DAMPER
FIXED 3/4" HORIZENTAL BARS 45° DEFLECTION
4-WAY THROW UNLESS OTHERWISE INDICATED
FACE BARS
DOUBLE DEFLECTION REGISTER WITH HORIZENTAL
PLASTER CEILINGS.
STANDARD FOR SURFACE MOUNTED UNITS ON
DIFFUSER PANELS SHALL BE THE MANUFACTURERS
ARCH. DWG. FOR CEILING TYPE. DIMENSIONS OF
MOUNTING IN SUSPENDED TILE CEILING SEE
NOMINAL 24"x24" 3-CONE DIFFUSER FOR
T
C
H W
R
C
H W
S D
C
H W
R
C
H W
S
D
T
D
E A
E A
FCU
CH
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
FCU
CH
FCUCH
CH
29 1
FCU
FCUCH
27 1
FCUCH
26 3
FCUCH
CH
CH
CH
EA
EA
SEE
SEE
FCU
FCU
(OUTDOOR UNIT)
SPLIT TYPE A/C UNIT
ACU
(INDOOR UNIT)
SPLIT TYPE A/C UNIT
ACU
THERMOSTAT(TYP)
HEATING & COOLING
COMBINATION TYPE
FCU
SEE (TYP)
300x200
150x200
RA : 750x200
SA : 500x150
SA : 600x200 x
600x200
250x150
250x150
250x150
250x150
300x150 300x150
700x150
250x100 x
700x150 700x150
500x150 x
500x150
250x150
250x100
250x150
250x150250x150250x150
250x150
68 LPS
R-1:600x100
64 LPS
R-1:600x100
64 LPS
R-1:600x100
118 LPS
R-1:600x100
92 LPS
R-1:600x100
68 LPS
S-1:200
64 LPS
S-1:200 x3
70 LPS
S-1:200
46 LPS
S-1:200 x2 x2
59 LPS
S-1:200
W/SPLASH BLOCK (TYP)
AND SPILL ON GRADE
40 DIA COND. DRAIN DROP
76 LPS
R-1:600x100 x2
41 LPS
S-1:200
38 LPS
S-1:200 x2
76 LPS
R-1:600x100
W/SPLASH BLOCK (TYP)
AND SPILL ON GRADE
40 DIA COND. DRAIN DROP
RELIEF LOUVER
1,000x400
SEE
EXHAUST AIR LOUVER
150x100
EXHAUST AIR LOUVER
600x200
250x250
150x100
EF
EXHAUST FAN
EF
EXHAUST FAN
56 LPS
E-1:200x150
83 LPS
E-1:300x200 250x100
JAN
200x100
NOTE :
4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
PIPING SHALL BE COPPER PIPING.
3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
UP
UP
D
D
W
W
1:100
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
NEW H.V.A.C PLAN (1st FLOOR)
- M12
- M12
- M12
- M11
M-7
GRAPHIC SCALE
SCALE: 1:100
0 2000 4000
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
SACLE = 1:100
NEW H.V.A.C PLAN (2nd FLOOR) M7
LAUNDRY
JAN
LOUNGE
219CORRIDOR
BED ROOM
201A
BED ROOM
201B
BED ROOM
202A
BED ROOM
202B
BED ROOM
203A
BED ROOM
203B
BED ROOM
204A
BED ROOM
204B
BED ROOM
205A
BED ROOM
205B
BED ROOM
206A
BED ROOM
206B
BED ROOM
207A
BED ROOM
207B
BED ROOM
208A
BED ROOM
208B
BED ROOM
214A
BED ROOM
214B
BED ROOM
213A
BED ROOM
213B
BED ROOM
212A
BED ROOM
212B
BED ROOM
211A
BED ROOM
211B
BED ROOM
210A
BED ROOM
210B
BED ROOM
209A
BED ROOM
209B
STAIR-2
218B
STAIR-1
218A
,9
,6
,9
,4
SACLE = 1:100
NEW H.V.A.C PLAN (3rd FLOOR) M7
BED ROOM
301A
BED ROOM
301B
BED ROOM
302A
BED ROOM
302B
BED ROOM
303A
BED ROOM
303B
BED ROOM
304A
BED ROOM
304B
BED ROOM
305A
BED ROOM
305B
BED ROOM
306A
BED ROOM
306B
BED ROOM
307A
BED ROOM
307B
BED ROOM
308A
BED ROOM
308B
319CORRIDOR
JAN
LAUNDRY
PURPOSE RM
MULTI
BED ROOM
314A
BED ROOM
314B
BED ROOM
313A
BED ROOM
313B
BED ROOM
312A
BED ROOM
312B
BED ROOM
311A
BED ROOM
311B
BED ROOM
310A
BED ROOM
310B
BED ROOM
309A
BED ROOM
309B
STAIR-2
STAIR-1
318A
,9
,6
,9
,4
FCU
CH
CH
FCU
CH
FCU
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
R
C
H W
S
T
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S
C
H W
R
C
H W
R C
H W
S
D
C
H W
R D
C
H W
S
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
C
H W
R
C
H W
S
D
T T
C
H W
R
C
H W
S D
E A
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
D
C
H W
R
C
H W
S
D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
D
C
H W
R C
H W
S D
T
D
C
H W
R
C
H W
S
D
D
C
H W
R
C
H W
S
D
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
D
C
H W
R
C
H W
S
D
D
C
H W
R
C
H W
S
D
D
C
H W
R
C
H W
S
D
D
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
C
H W
S
D C
H W
R
C
H W
R
C
H W
S
D
D
C
H W
R C
H W
S D
D
C
H W
R C
H W
S D
D
C
H W
R C
H W
S D
D
C
H W
R C
H W
S D
D
C
H W
R C
H W
S D
D
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
S D
C
H W
R
C
H W
R C
H W
S D
C
H W
R
C
H W
S
C
H W
R
C
H W
R C
H W
S C
H W
R
C
H W
S
D
C
H W
R D
C
H W
S
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
T
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
D C
H W
R
C
H W
S
C
H W
R
C
H W
S
D
T
CH
CH
EA
EA
1 EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
FCU
FCU
THERMOSTAT(TYP)
HEATING & COOLING
COMBINATION TYPE
SEE
SEE
SEE
SEE
FCU
CH
CH
FCU
CH
FCU
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
FCU
CH
CH
CH
EA
EA
1 EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
FCU
FCU
THERMOSTAT(TYP)
HEATING & COOLING
COMBINATION TYPE
SEE
SEE
SEE
SEE
SEE
SEE 1
RH
W/ WALL CAP
RANGE HOOD
NOTE :
4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
PIPING SHALL BE COPPER PIPING.
3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
UPDN
UPDN
REF
D
D
W
W
UPDN
UPDN
REF
D
D
W
W
1:100
NEW H.V.A.C PLAN (2nd & 3rd FLOOR)
- M12
- M12
- M12
- M12
- M12
- M12
- M12
- M12
- M12
- M12
NOTE ON INSTALLATION OF PIPE INSULATION :
THE INSTALLATION OF THE PIPE INSULATION IS COMPLETED.
4. THE CONTRACTOR SHALL INVITE THE MECH. ENGINEER FOR QUALITY INSPECTION WHEN
50 WHEN TESTED IN ACCORDANCE WITH ASTM E84.
A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF
3. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND SHALL HAVE
2. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.
SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.
1. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23 07 00, AND
LAUNDRY
JAN
PURPOSE RM
MULTI
419CORRIDOR
BED ROOM
414A
BED ROOM
414B
BED ROOM
413A
BED ROOM
413B
BED ROOM
412A
BED ROOM
412B
BED ROOM
411A
BED ROOM
411B
BED ROOM
410A
BED ROOM
410B
BED ROOM
409A
BED ROOM
409B
BED ROOM
401A
BED ROOM
401B
BED ROOM
402A
BED ROOM
402B
BED ROOM
403A
BED ROOM
403B
BED ROOM
404A
BED ROOM
404B
BED ROOM
405A
BED ROOM
405B
BED ROOM
406A
BED ROOM
406B
BED ROOM
407A
BED ROOM
407B
BED ROOM
408A
BED ROOM
408B
STAIR-2
418B
STAIR-1
418A
,9
,6
,9
,4
M-8
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
GRAPHIC SCALE
SCALE: 1:100
0 2000 4000
SACLE = 1:100
NEW H.V.A.C PLAN (4th FLOOR) M8
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
FCU
EF
EF
EF
EF
EF
EF
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
EA
50 65
BALANCING VALVE(TYP)
CIRCUIT SETTER SEE (TYP)
EF
(TYP OF 7)
EXHAUST FAN
50 65
250x150
250x150 250x250
250x150 250x150 250x150 250x150 250x150 250x150
250x250 250x250 250x250 250x250 250x250
THERMOSTAT(TYP)
HEATING & COOLING
COMBINATION TYPE
(TYPICAL)
NEW PIPE ANCHOR
BELLOWS TYPE (TYP.)
NEW EXPANSION JOINT
(TYPICAL)
NEW PIPE GUIDE
SEE
SEE (TYP)
SEE
SEE
C
H W
S
D C
H W
R
C
H W
S D
C
H W
R
C
H W
R D
T
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S D
C
H W
R
C
H W
S
C
H W
R
C
H W
S
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
E A
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
D C
H W
R
C
H W
S
T
C
H W
R
C
H W
S D
T
D C
H W
R
C
H W
S
C
H W
R C
H W
S
C/HWR
C/HWS
C/HWR
C/HWS
C/HWR
C/HWS
C
H W
S C
H W
R
C/HWS
C/HWR
C/HWS
C/HWR
C/HWS
C/HWR
NOTE :
4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
PIPING SHALL BE COPPER PIPING.
3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN
DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
HVAC PIPING (HOT/CHILLED WATER PIPING AND
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
IN FIELD (TYP.).
AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
UPDN
UPDN
REF
D
D
W
W
61,169
7,721 7,620 7,620 7,620 7,620 7,620 7,620 7,729
NEW H.V.A.C PLAN (4th FLOOR)
1:100
- M12
- M12
- M12
- M12
- M12
M-9 1:100
GRAPHIC SCALE
SCALE: 1:100
0 2000 4000
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
NOTE :
DUCTWORK PRIOR TO DUCTWORK INSTALLATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
C.O
STAIR-1
119A
LAUNDRY
JAN
VEST
MECH ROOM
MULTI-PURPOSE RM
114B
STORAGE
ROOM
SPRINKLER
MULTI-PURPOSE RM
114A
CORRIDOR
MALE
113A
COMMO SHOP
FEMALE
113B
STORAGE
VEST
ROOM
COMMUNITY
ADMIN OFFICE
NBC ROOM
SUPPLY ROOM
COMM
XO
CO
STORAGE
106C
WAIT AREA
STORAGE
105A
R.O
106B
T.O
106A
STAIR-2
119B
102B
BED ROOMBED ROOM
102A
BED ROOM
101B
BED ROOM
101A
LAUNDRY
JAN
LOUNGE
219CORRIDOR
BED ROOM
201A
BED ROOM
201B
BED ROOM
202A
BED ROOM
202B
BED ROOM
203A
BED ROOM
203B
BED ROOM
204A
BED ROOM
204B
BED ROOM
205A
BED ROOM
205B
BED ROOM
206A
BED ROOM
206B
BED ROOM
207A
BED ROOM
207B
BED ROOM
208A
BED ROOM
208B
BED ROOM
214A
BED ROOM
214B
BED ROOM
213A
BED ROOM
213B
BED ROOM
212A
BED ROOM
212B
BED ROOM
211A
BED ROOM
211B
BED ROOM
210A
BED ROOM
210B
BED ROOM
209A
BED ROOM
209B
JAN
STAIR-2
218B
STAIR-1
218A x
150x100
150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100150x100 150x100 150x100 150x100 150x100 150x100 150x100
150x100150x100150x100150x100150x100150x100150x100 150x100150x100150x100150x100150x100
VD VD
VDVD
VD
200x150
VD
VDVD
250x200VDVD 350x200VDVD
VDVD
500x250
VD
450x250
VD VD
400x250
VD VD
VD VD
350x250VDVD
VDVD
VD VD
VD VD
500x250
,9
,6
,9
,4
OAU
OUTSIDE AIR UNIT
L P
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
SACLE = 1:100M9
,9
,6
,9
,4
61,169
11,557 3,784 7,620 7,620 7,620 7,620 4,878 3,327 3,204 3,939
"EMERGENCY HVAC SHUT-OFF SWITCH"
WITH CLEAR FLIP-COVERLABELLED AS
HVAC EMERGENCY SHUT-OFF SWITCH
COMM RM
NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (1st FLOOR)
SACLE = 1:100
NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (2nd FLOOR)
(1st & 2nd FLOOR)
NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM
x
OAU
OUTSIDE AIR UNIT
"EMERGENCY HVAC SHUT-OFF SWITCH"
WITH CLEAR FLIP-COVERLABELLED AS
HVAC EMERGENCY SHUT-OFF SWITCH
S x
150x100150x100
S x
150x100
S x
S x
150x1002
S x
S x
S x
S x
S x
S x
S x
VD
VD
150x100VD200x150 VD
VD
VD
VDVD
250x200 200x100350x200 VD
VDVD
x
400x200
OHPU
HEAT PUMP UNIT
SPLIT SYSTEM
OUTDOOR
NEW CONC. PAD
UP
UP
D
D
W
W
UPDN
UPDN
REF
D
D
W
W
M9
LAUNDRY
JAN
PURPOSE RM
MULTI
419CORRIDOR
BED ROOM
414A
BED ROOM
414B
BED ROOM
413A
BED ROOM
413B
BED ROOM
412A
BED ROOM
412B
BED ROOM
411A
BED ROOM
411B
BED ROOM
410A
BED ROOM
410B
BED ROOM
409A
BED ROOM
409B
BED ROOM
401A
BED ROOM
401B
BED ROOM
402A
BED ROOM
402B
BED ROOM
403A
BED ROOM
403B
BED ROOM
404A
BED ROOM
404B
BED ROOM
405A
BED ROOM
405B
BED ROOM
406A
BED ROOM
406B
BED ROOM
407A
BED ROOM
407B
BED ROOM
408A
BED ROOM
408B
STAIR-2
418B
STAIR-1
418A x
150x100
150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100150x100 150x100 150x100 150x100 150x100 150x100 150x100
150x100150x100150x100150x100150x100150x100150x100 150x100150x100150x100150x100150x100
VD VD
VDVD
VD
200x150
VD
VDVD
250x200VDVD 350x200VDVD
VDVD
500x250
VD
450x250
VD VD
400x250
VD VD
VD VD
350x250VDVD
VDVD
VD VD
VD VD
500x250
M-10 1:100
GRAPHIC SCALE
SCALE: 1:100
0 2000 4000
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
NOTE :
DUCTWORK PRIOR TO DUCTWORK INSTALLATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR
AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE
,9
,6
,9
,4
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
BED ROOM
301A
BED ROOM
301B
BED ROOM
302A
BED ROOM
302B
BED ROOM
303A
BED ROOM
303B
BED ROOM
304A
BED ROOM
304B
BED ROOM
305A
BED ROOM
305B
BED ROOM
306A
BED ROOM
306B
BED ROOM
307A
BED ROOM
307B
BED ROOM
308A
BED ROOM
308B
319CORRIDOR
JAN
LAUNDRY
PURPOSE RM
MULTI
BED ROOM
314A
BED ROOM
314B
BED ROOM
313A
BED ROOM
313B
BED ROOM
312A
BED ROOM
312B
BED ROOM
311A
BED ROOM
311B
BED ROOM
310A
BED ROOM
310B
BED ROOM
309A
BED ROOM
309B
STAIR-2
STAIR-1
318A
61,169
7,721 7,620 7,620 7,620 7,620 7,620 7,620 7,729
,9
,6
,9
,4
150x100
150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100150x100 150x100 150x100 150x100 150x100 150x100 150x100
150x100150x100150x100150x100150x100150x100150x100 150x100150x100150x100150x100150x100
VD VD
VDVD
VD
200x150
VD
VDVD
250x200VDVD 350x200VDVD
VDVD
500x250
VD
450x250
VD VD
400x250
VD VD
VD VD
350x250VDVD
VDVD
VD VD
VD VD
500x250
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x
S x x
"EMERGENCY HVAC SHUT-OFF SWITCH"
WITH CLEAR FLIP-COVERLABELLED AS
HVAC EMERGENCY SHUT-OFF SWITCH
"EMERGENCY HVAC SHUT-OFF SWITCH"
WITH CLEAR FLIP-COVERLABELLED AS
HVAC EMERGENCY SHUT-OFF SWITCH
SACLE = 1:100
NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (4th FLOOR)
SACLE = 1:100
NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (3rd FLOOR)
(3rd & 4th FLOOR)
NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM
OAU
OUTSIDE AIR UNIT
OAU
OUTSIDE AIR UNIT
UPDN
UPDN
REF
D
D
W
W
UPDN
UPDN
REF
D
D
W
W
M10
M10
M-11
MECHANICAL
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
M11 SACLE = 1:50
MECHANICAL ROOM ENLARGED PARTIAL PLAN
ET
DOMESTIC H.W SYSTEM
EXPANSION TANK FOR
ET
CHILLED WATER SYSTEM
EXPANSION TANK FOR
ET
HOT WATER SYSTEM
EXPANSION TANK FOR
EF
EXHAUST FAN
UH
UNIT HEATER
REDUCING VALVE
PRESSURE
AS
HOT WATER SYSTEM
AIR SEPARATOR FOR
AS
CHILLED WATER SYSTEM
AIR SEPARATOR FOR
P
CIRCULATION PUMP
DOMESTIC HOT WATER
P
RECIRCULATION PUMP
DOMESTIC HOT WATER
WC
WATER CHILLER
DRAN PIT
C.O
VEST
MECH ROOM
C.O
MECH ROOM
VEST
NOTE :
WITH THE MANUFACTURER'S RECOMMENDATIONS.
3. THE DIAMETER OF THE SMOKE STACK IS IN ACCORDANCE
DOMESTIC WATER PIPING PRIOR TO PIPING INSTALLATION.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC &
DIRECTION OF PIPING IN FIELD (TYP.).
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND
FLEXIBLE CONNECTOR (TYP.)
THERMOSTAT (TYP.)
FLOW SWITCH
DT
STORAGE TANK
DOMESTIC HOT WATER
FOR PLUMBING PIPINGFOR H.V.A.C PIPING
FCU
FAN COIL UNIT
P
CIRCULATION PUMP
HOT WATER
P
CIRCULATION PUMP
CHILLED WATER
TO REMAIN
AIR HANDLING UNIT
EXISTING
DWH
HOT WATER HEATER
DOMESTIC
BOOSTER PUMP TO REMAIN
EXISTING DOMESTIC WATER
P.O.C
P.O.C
P.O.C
P.O.C
TO REMAIN
LOUVER W/ DUCT
EXISTING
750x200(E)
750x200(N)
FD
32(E)32(N)
100,100,40
FD
FD
600x200(N) x
E x
E
500x150(N)
(TYP)
FEEDER
CHEMICAL
20,20
(TOP & BOTTOM LEVEL)
INTAKE LOUVER
& COMBUSTION AIR
600x600 O.A. INTAKE
HEATING THERMOSTAT
(FOR HEATING SYSTEM)
OUTDOOR AIR THERMOSTAT
(FOR COOLING SYSTEM)
OUTDOOR AIR THERMOSTAT
60°C
43.3°C
S V
V S
FOS
FOR
FOR
FOS
(UNDERGROUND PIPING)
100,100
THERMOSTAT FOR EF-2
VENTINATION
BAROMETRIC DAMPER (TYP)
300 DIA SMOKE STACK WITH
BAROMETRIC DAMPER (TYP)
250 DIA SMOKE STACK WITH
CONTROL VALVE
MODULATING 3-WAY
D D
MD
C W
S
C W
R
C W
S
C W
R
CWS
CWR
HT
VTOTOT
EXHAUST AIR GRILLE
1,100x700
750x300
I N
T A
K E
O
U V
E R x
A
B
HOT WATER BOILER
E
A
U V
E R x
50 FD
50 FD
100 FCO
PREVENTER
BACK-FLOW
WATER METER
65mm
FD
3-WAY MIXING VALVE
THERMOSTATIC
65,50,32,32
65,65,25
LINES
FUEL OIL
NEW
OIL FILTER (TYP)
BALL CHECK VALVE (TYP)
SHUT-OFF VALVE (TYP)
AUTO SAFETY
ENLARGED PARTIAL PLAN
MECHANICAL ROOM
1:50
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
M-12
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
M12
20 20
NEW H.V.A.C & H.V.A.C PIPING ENLARGED PARTIAL PLANS
SACLE = 1:50
SCALE: 1:50
0 1000 2000
GRAPHIC SCALE
BED ROOMBED ROOM
T T
VEST
LAUNDRY ROOM HVAC PARTIAL PLAN (TYP.)
M12 NOT TO SCALE
NEW H.V.A.C PIPING ISOMETRIC DIAGRAM
AS SHOWN
NEW H.V.A.C PIPING ISOMETRIC DIAGRAM
ENLARGED PARTIAL PLANS AND
NEW H.V.A.C & H.V.A.C PIPING
C
H W
S
C
H W
R
T S
W C
H
M
AHU
AIR HANDLING UNIT
O.A INTAKE LOUVER
600x200
198.2 LPS
S-2:400x400
450x200
450x200
EF
EXHAUST FAN
E.A LOUVER
600x200 200 DIA WALL VENT
E.A LOUVER
200x200
CONNECT TO VENT (TYP)
100 DIA DRYER VENT
150x100
198.2 LPS
E-2:400x400
EF
EXHAUST FAN
450x200
REMAIN (TYPICAL)
DRYER VENT TO BE
COND. DRAIN (TYP)
ACCESS DOOR
(1ST FL. ONLY)
FOR CONT. SEE
20 DIA COND, DRAIN
MODULATING 3-WAY CONTROL VALVE
CHWS & CHWR (TYP)
NOTE :
4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.
3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN PIPING SHALL BE COPPER PIPING.
2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING (HOT/CHILLED WATER PIPING AND DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.
1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING IN FIELD (TYP.).
NEW TYP MODULE HVAC PARTIAL PLAN
(1ST FLOOR)
NEW TYP MODULE HVAC PARTIAL PLAN
(2ND THRU 4TH FLOOR)
THERMOSTAT(TYP)
HEATING & COOLING
COMBINATION TYPE
F.D
EXHAUST DUCT RISER
250x150
EF
EXHAUST FAN
150x100
FCU
FAN COIL UNIT
FCU
20 (CHWR)
20 (CHWS)
25 (D)25 (D)
20 (CHWS)
20 (CHWR)
(TYPICAL)
SEE ARCH. DWG
PIPE ENCLOSURE
NOZZLE W/SPLASH BLOCK (TYP)
AND CONNECT TO DOWN SPOUT
40 DIA COND. DRAIN DROP
COND. DRAIN (TYP)
CHWS & CHWR &
T T
THERMOSTAT(TYP)
HEATING & COOLING
COMBINATION TYPE
F.D
EXHAUST DUCT RISER
250x150
EF
EXHAUST FAN
150x100
FCU
FAN COIL UNIT
FCU
20 (CHWR)
20 (CHWS)
25 (D)25 (D)
20 (CHWS)
20 (CHWR)
(TYPICAL)
SEE ARCH. DWG
PIPE ENCLOSURE
NOZZLE W/SPLASH BLOCK (TYP)
AND CONNECT TO DOWN SPOUT
40 DIA COND. DRAIN DROP
COND. DRAIN (TYP)
CHWS & CHWR &
SEE
4TH
FL
H
VAC
PLAN
AUTO
AI
R
VENT
1S T
FL
OOR
2ND
FL
OOR
4TH
FL
OOR
3RD
FL
OOR
1S T
FL
OOR
2ND
FL
OOR
4TH
FL
OOR
3RD
FL
OOR
C H
W S
C H
W R
D C
H W
S C
H W
R
DC
H
W S
C H
W R
D D
CHW
R
CHW
S
CHW
SCHW
R
SP
IL
L
OVER
SP
LAS
H
BLOCK
TO
DOW
N
SP
OUT
NOZZLE
A
ND
DI
A
COND.
D
RAI
N
CONNECT
SP
IL
L
OVER
SP
LAS
H
BLOCK
TO
DOW
N
SP
OUT
NOZZLE
A
ND
DI
A
COND.
D
RAI
N
CONNECT
HVAC
PLAN
SEE
4TH
FL
AUTO
AI
R
VENT
HVAC
PLAN
SEE
4TH
FL
BED ROOMBED ROOM
STAIR-1
119A
218A
318A
418A
JAN
UP
D
D
W
W
- M6
M-13
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON, DPW, USAG-RED CLOUD
HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD
US ARMY INSTALLATION MANAGEMENT COMMAND
DEPARTMENT OF THE ARMY
A
B C D
E F G H
SHEET OF
M13 NOT TO SCALE
NEW H.V.A.C PIPING SCHEMATIC FLOW DIAGRAM - 1
NOTE :
WITH THE BALANCING VALVE INSTRUCTIONS.
TO CHILLED AND HEATING WATER FLOW RATES IN ACCORDANCE
THAT HAVE CIRCUIT SETTERS & BALANCE THE CIRCUIT SETTER
2. CONTRACTOR SHALL ADD ALL THE FLOW RATES ON THE LINES
1. HORIZONTAL PIPE LINE'S SIZES ARE SHOWN ON PIPING PLANS.
AUTO AIR VENT(TYP)
1ST FL
2ND FL
3RD FL
4TH FL
ROOF
FCU
FCU
FCU
FCU
114A
FCU
FCU
114A
FCU
FCU
114A
FCU
FCU
114A
FCU
FCU
FCU
FCU
FCU
FCU
AHU
AHU
AHU
AHU
40 20
40 25
32 32
CH
40100100
40100100
25100100
CH
BALANCING VALVE(TYP)
RISER CIRCUIT SETTER
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
CH
EXPANSION JOINT
BELLOWS TYPE
(TYPICAL)
AUTO AIR VENT
25 32
401A
FCU
FCU
401B
FCU
FCU
25 25
402A
FCU
FCU
25 25
402B
FCU
FCU
25 25
403A
FCU
FCU
25 25
406B
FCU
FCU
25 25
406A
FCU
FCU
25 25
405B
FCU
FCU
25 25
405A
FCU
FCU
25 25
404B
FCU
FCU
25 25
404A
FCU
FCU
25 25
403B
FCU
FCU
25 25
306B
FCU
FCU
40 25 25
306A
FCU
FCU
305B
FCU
FCU
305A
FCU
FCU
304B
FCU
FCU
304A
FCU
FCU
303B
FCU
FCU
303A
FCU
FCU
302B
FCU
FCU
302A
FCU
FCU
301B
FCU
FCU
301A
FCU
FCU
40 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 32 40 25 25
206B
FCU
FCU
206A
FCU
FCU
205B
FCU
FCU
205A
FCU
FCU
204B
FCU
FCU
204A
FCU
FCU
203B
FCU
FCU
203A
FCU
FCU
202B
FCU
FCU
202A
FCU
FCU
201B
FCU
FCU
201A
FCU
FCU
40 25 2540 25 2540 25 2540 25 2540 25 25
100 100
50 50
C H
W R
C H
W S
C H
W R
C H
W S
C H
W R
C H
W S
C H
W R
C H
W S
D D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
CHWS
CHWR
D
CHWR
CHWR
CHWS
CHWR
CHWS
CHWR
CHWS
CHWR
CHWS
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
C H
W S
C H
W R
D C
H W
S C
H W
R
D
SCHEMATIC FLOW DIAGRAM - 1
NEW H.V.A.C PIPING
M-14
SYMBOL BY
DESIGNED BY
ENERGY MANAGER
SUBMITTED BY
USING AGENCY
APPROVED BY
PROJECT NO. DRAWING NO. REF NO.
SCALE :
ZONE DATE APVD.
UTILITIES
REVIEWED BY
DESCRIPTION
BLDGS & GROUNDS
CHIEF, ENGR'G DIV
DES
CHK'D
REVISIONS
IMCOM
FIRE & EMERGENCY SVC
SAFETY
ENVIRONMENT
UNIT #15707, APO AP 96258-5707
ENGINEERING DIVISON,…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .