Atta 1-5 Drawings_Non-WorkPlanLCS_MECH.pdf

PDF 9 MB Posted

Attached to
Multiple Award Indefinite Delivery and Indefinite Quantity (MA IDIQ) General Construction contract funded by LCS
Solicitation number
W91QVN23R0026
Issued by

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

M-1

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

o

ACCU AIR COOLED CONDENSING UNIT

ACLD AIR COOLED

ACU AIR CONDITION UNIT (S)

ACV ALARM CHECK VALVE

ADP APPARATUS DEW POINT

AHU AIR HANDLING UNIT

AIR COND AIR CONDITION (-ING,-ED)

AL ALUMINUM

ALT ALTITUDE

AMB AMBIENT

AMP AMPERE(AMP, AMPS)

APPROX APPROXIMATE

AVG AVERAGE

AWG AMERICAN WIRE GAUGE

BARO BAROMETER(-TRIC)

BARO PR PRESSURE, BAROMETRIC

BHP BRAKE HORSEPOWER

BP BOILING POINT

CAP CAPACITY

CCW COUNTER CLOCKWISE

CHW CHILLED WATER

CKT CIRCUIT

CLASS CLASSIFICATION

CLG LOAD COOLING LOAD

COEF COEFFICIENT

CONN CONNECTION

CONT

C

CMH CUBIC METER PER HOUR

CU M CUBIC METER

CENTIGRADE/ CELCIUS

CFCI

CONTRACTOR INSTALLED

CONTRACTOR FURNISHED

CIP CAST IRON PIPE

CWP

CU MM CUBIC MILLIMETER

Cv COEFFICIENT, VALVE FLOW

CW CLOCKWISE OR COLD WATER

CIRCULATING WATER PUMP

DB DECIBEL OR DRY BULB

COMPRESSORCPRSR

DBT DRY BULB TEMPERATURE

DCWS DOMESTIC COLD WATER SUPPLY

DEG or ° DEGREE

DFW DIESEL OIL

DOMESTIC HOT WATER RETURN

DOMESTIC HOT WATER SUPPLY

DHWR

DHWS

DIRECT EXPANSIONDX

DRY PIPE VALVEDPV

DOUBLE POLE DOUBLE THROWDPDT

DEWPOINT TEMPERATUREDPT

DIVISIONDIV

DIFFERENCEDIFF

DIAGRAMDIAG

DIAMETERDIA or

DWG DRAWING

EXPANSION JOINTEXPJT

ENTERING WATER TEMPEWT

EVAPORAT (-E,-ING,-ED,-OR)EVAP

EXTERNAL STATIC PRESSUREESP

EXPLOSION PROOFEP

EQUIPMENTEQPT

ENTERINGENT

EFFICIENCYEFF

EQUIVALENT DIRECT RADIATIONEDR

ECONOMIZERECON

ECCENTRICECC

ENTERING AIR TEMPERATUREEAT

FUEL OILFO

FA FACE AREA OR FRESH AIR

FHC FIRE HOSE CABINET

FHY FIRE HYDRANT

FLA FULL LOAD AMPERES

F FARENHEIT

FLR FLOOR

FEED WATER PUMPFWP

FACE VELOCITYFVEL

FLUSH VALVEFV

FRP

FREQUENCYFREQ

FEMALE PIPE THREADFPT

FIBERGLASS REINFORCED PLASTIC

Ft or ' FEET

FXTR FIXTURE

GALVANIZED STEELGALVS

GAGE OR GAUGEGA

GR GRAMS

GOVERNMENT INSTALLED

GOVERNMENT FURNISHED GFGI

CONTRACTOR INSTALLED

GOVERNMENT FURNISHEDGFCI

GAL GALLONS

GALLONS PER MINUTEGPM

HERTZHZ

HORIZONTALHORIZ

HOT WATER HEATERHWH

HOT WATERHW

HOUR(S)HR

HORSEPOWERHP

MERCURYHG

HEADHD

HB HOSE BIBB

DIAMETER, INSIDEID

ISOMETRICISO

IRON PIPE SIZEIPS

J JOULE

K THERMAL CONDUCTIVITY

K THERMAL CONDUCTIVITY

kG kCAL/HR

KILOGRAM

kG/SQ CM KILOGRAM PER SQ. CENTIMETER kG/SQ CM A

KILOCALORIE PER HOUR

(ABSOLUTE)

KILOGRAM PER SQ. CENTIMETER

kG/SQ CM G

(GAUGE)

KILOGRAM PER SQ. CENTIMETER

kG/SM KILOGRAM PER SQ. METER kG/SM A kG/SM G

(ABSOLUTE)

KILOGRAM PER SQ. METER

KILOGRAM PER SQ. METER (GAGE)

kW KILOWATT kWH KILOWATT HOUR kJ KILOJOULE kPa KILO PASCAL

LAT LEAVING AIR TEMPERATURE

LBS POUNDS

LG LENGTH

LH LATENT HEAT

LWT LEAVING WATER TEMPERATURE

LIQUID LINELL

L LITERS

LPD LITERS PER DAY

LPH LITERS PER HOUR

LPS

LM LINEAR METER

LITERS PER SECOND

LAV LAVATORY

LPM LITERS PER MINUTE

LT LAUNDRY TRAY

NUMBERNO

NORMALLY OPENN.O.

NOT IN CONTRACTNIC

NORMALLY CLOSEDN.C.

NOISE CRITERIANC

NCK

MAX

NOT TO SCALENTS

MIN

MPH

M METERS

MAXIMUM

MINIMUM OR MINUTE

METERS PER HOUR

MPS METERS PER SECOND

MM MILLIMETER

NPT NATIONAL TAPER PIPE (THREAD)

NOT APPLICABLEN/A

NECK

MECH MECHANICAL

OS&Y OUTSIDE SCREW & YOKE

OD

OAIL OUTSIDE AIR INTAKE LOUVER

OA OUTSIDE AIR

OUTSIDE DIAMETER

OPNG OPENING

OXY OXYGEN

PERCENT

PRESSURE REDUCING VALVEPRV

PARTS PER MILLIONPPM

POINT OF CONNECTIONPOC

PLUMBINGPLMB

PHASE (ELECTRIC)PH

PRESSURE GAGEPG

PD

POLEP

PRESSURE DROP OR DIFFERENCE

Pa PASCAL

POL PETROLEUM, OIL AND LUBRICANTS

QUANTITYQTY

QUARTQT

REFRIGERATION TONRT

REVOLUTIONS PER MINUTERPM

RADIATORRDTR

RETURN AIRRA

THERMAL RESISTANCER

REFRIGERANT (134A, 22, ETC)R134A,R22

RH RELATIVE HUMIDITY

SUPPLY AIRSA

SYMBOLSYM

SUCTIONSUCT

STORAGESTOR

STEELSTL

STANDARDSTD

STEAMST

SAYBOLT SECONDS UNIVERSALSSU

STAINLESS STEELSST

SAYBOLT SECONDS FUROLSSF

SQUARESQ

SPECIFICATIONSPEC

SINGLE POLE DOUBLE THROWSPDT

SM

LPH, STANDARD CONDITIONSSLPH

LPS, STANDARD CONDITIONSSLPS

SG

SLPD LPD, STANDARD CONDITIONS

SL SENSIBLE LOAD

SH SENSIBLE HEAT

SPECIFIC GRAVITY

SF SAFETY FACTOR

SEC SECOND

SCH SCHEDULE

STATIC PRESSURE

SQUARE METER

SP

SBM

SAN SANITARY

SUBMERSIBLE

TYPICALTYP

THERMOSTATTSTAT

TONS OF REFRIGERATIONTONS

THICKNESSTHK

THERMOMETERTHERM

TEMPERATURETEMP

TEMPERATURE DIFFERENCETD

UNIT HEATERUH

HEAT TRANSFER COEFFICIENTU

WTRPRF

WT

WSHR

WITHW/

WH

WIDTHWD

WCLD

WC

WBT

WB

WATTW

VP

VOL

VISC

VERTICALVERT

VENTILATIONVENT

VELOCITYVEL

VARIABLE AIR VOLUMEVAV

VAC VACUUM

VLV VALVE

V VOLT

WATERPROOF

WEIGHT

WASHER

WATTHOUR OR WATER HEATER

WATER-COOLED

WATER CLOSET

WET BULB TEMPERATURE

WET BULB

PRESSURE, DYNAMIC(VELOCITY)

VOLUME

VISCOSITY

VTR VENT THRU ROOF

UR URINAL

A B B R E V I A T I O N S

MECHANICAL MATERIAL INDICATIONS AND SYMBOLS

FS

VFM

OFM

AVA

PRESSURE RELIEF

TEMPERATURE

EXPANSION LOOP

EXPANSION JOINT

ANCHOR, INTERMEDIATE

ALIGNMENT GUIDE

AIR VENT, AUTOMATIC

SQUARE HEAD BALANCING COCK

QUICK OPENING

NEEDLE

LOCK SHIELD

FLEXIBLE CONNECTOR

FLOWMETER, ORIFICE

FLOWMETER, VENTURI

FLOW SWITCH

PRESSURE GAUGE AND COCK

STRAINER

THERMOMETER

PRESSURE REDUCING

RELIEF OR SAFETY

SLEEVE

BLOW OFF STRAINER

INLINE PUMP

SAFETY

FLOAT

valves, special duty

S

M

GATE, NORMALLY CLOSED

GLOBE

SOLENOID

3 WAY MANUAL

GATE, NORMALLY OPEN

PLUG

MOTOR OPERATED GATE

MOTOR OPERATED GLOBE

3 WAY ELECMOTOR CONTROL

3 WAY AIR MOTOR CONTROLLER

HOSE GATE

HOSE GLOBE

POST INDICATOR

OS Y

ANGLE GLOBE

ANGLE GATE

SWING GATE CHECK

S

M

P

M

M

ALARM CHECK

DRY PIPE

DELUGE

PREACTION

TAMPER DETECTION SWITCH

QUICK OPENING DEVICE

NON-RISING STEM

DIAPHRAGM

SOLENOID

MOTOR ELECTRIC

valve actuators

POTABLE COLD WATER

POTABLE HOT WATER

POTABLE HOT WATER RETURN

PIPE SLEEVE

BACKFLOW PREVENTER

PITCH OR PIPE, UP(U), DOWN(D)

VENT THRU ROOF

SURFACE CLEANOUT

FLOOR CLEANOUT

FLOOR DRAIN

PIPE SLEEVE WITH FIRE STOPPING

HOSE BIBB

FLOOR SINK (200mm x 200mm)

HOT WATER (60°C)

HOT WATER (82.22°C)

VENT

SANITARY SEWER

COMPRESSED AIR

FUEL OIL SUPPLY

FUEL OIL RETURN

FLOOR DRAIN WITH CLEANOUT

FLOOR DRAIN WITH DEEP TRAP

FLOOR DRAIN WITH NO TRAP

FLOOR DRAIN WITH TRAP TIME

FD

FCO

SCO

200x200

FIRE PROTECTION WATER SUPPLY

MAIN SUPPLY SPRINKLER

WET STANDPIPE

DRY STANDPIPE

COMBINATION STANDPIPE

plumbing sprinkler

DSP

WSP

CSP

S

F

PLAN ELEV

82.22°C

60°C

S

A

FOS

FOR

RD

RS

RL

D

CWS

CWR

LPC

BBD

PC

VPD

MU

FOD

FOV

FOG

FOS

FOR

HWS

M

HCS

HCR

FILL

MU

HWR

LOW PRESSURE CONDENSATE

BOILER BLOW DOWN

PUMPED CONDENSATE

VACUUM PUMP DISCHARGE

MAKE UP WATER

FUEL OIL DRAIN

FUEL OIL TANK VENT

FUEL OIL GAUGE

FUEL OIL SUPPLY

FUEL OIL RETURN

CONTROL AIR MAIN

DUAL TEMPERATURE RETURN

FILL LINE

MAKE UP WATER

DUAL TEMPERATURE SUPPLY

WATER SUPPLY

LOW TEMPERATURE HOT

WATER RETURN

LOW TEMPERATURE HOT

SPLITTER DAMPER

REFRIGERANT DISCHARGE

REFRIGERANT SUCTION

REFRIGERANT LIQUID

DRAIN

CHILLED WATER SUPPLY

CHILLED WATER RETURN

dampers piping heating air conditioning and refrigeration

DU 13mm

47.2

94.4

DG

300x150

500/300L

R

AD

FC

SG

SR

RG

RR

810mm x 400mm

810mm x 400mm

810mm x 400mm

EG

ER

810mm x 400mm

DIRECTION OF FLOW

FLEXIBLE CONNECTION

TRANSITION

(810mm WIDTH x 400mm DEPTH)

DUCT SIZES SHOWN

RISE(R), DOWN(D)

CHANGE OF ELEVATION

VERTICAL OR HORIZONTAL

ACCESS DOOR,

FIRST FIGURE IS ON TOP

POSITIVE PRESS.,

OUTSIDE AIR DUCT SECTION,

FIRST FIGURE IS ON TOP

POSITIVE PRESS.,

SUPPLY AIR DUCT SECTION,

FIRST FIGURE IS ON TOP

SECTION, NEGATIVE PRESS.,

RETURN OR EXHAUST AIR DUCT

SUPPLY OR RETURN

FLEXIBLE AIR DUCT,

TRANSITION

SQUARE TO ROUND

REGISTER, CEILING

EXHAUST AIR GRILLE OR

REGISTER, SIDEWALL

SUPPLY AIR GRILLE OR

REGISTER, CEILING

RETURN AIR GRILLE OR

OR REGISTER, CEILING

SUPPLY AIR MODULAR DIFFUSER

DOOR GRILLE (300mmx150mmH)

(500mmWx300mmH, 94.4 LPS)

LOUVER, DOOR OR WALL

(13mm, 47.2 LPS)

DOOR UNDERCUT

duct works grilles, registers and diffusers

LEGEND & ABBREVIATIONCONTINUE / CONTINUATION

fittings

TEE, SINGLE SWEEP

UNION, SCREWED

UNION, FLANGED

CONNECTION, TOP

ELBOW, 90°

ELBOW, TURNED UP

ELBOW, TURNED DOWN

TEE, OUTLET UP

TEE, OUTLET DOWN

CONNECTION, BOTTOM

REDUCER, CONCENTRIC

(STRAIGHT, INVERT)

REDUCER, ECCENTRIC

(STRAIGHT, DOWN)

REDUCER, ECCENTRIC

TEE

ELBOW, 45°

LATERAL

SOLVENT CEMENT

BELL AND SPIGOT

SCREWED

FLANGED

WELDED

SOLDERED/BRAZED

M

NS

BUTTERFLY

BALL

DIAPHRAGM

GATE

INDICATING BUTTERFLY

KEY OPERATED

CHECK

DELUGE VALVE

WALL MOUNTED TEST HEADER

FIRE ALARM BELL

HOSE STATION DRY STANDPIPE

MINI HORN

HORN SPEAKER

WALL HYDRANT 2 HOSE OUTLET

SMOKE DETECTOR

CUTTING POINT

CAP

NON-SPRINKLERED SPACE

RISER

CONNECTION (2-WAY SHOWN)

SIAMESE FIRE DEPARTMENT

CONNECTION

SINGLE FIRE DEPARTMENT

valves

UPRIGHT SPRINKLER (K=5.6)

SIDEWALL SPRINKLER (K=5.6)

UPRIGHT SPRINKLER (K=8.0)

PENDENT SPRINKLER (K=5.6)

PENDENT SPRINKLER (K=8.0)

RESIDENTIAL PENDENT SPRINKLER (K=4.9)

REPAIR BARRACKS

FIRE PROTECTION AND MECHANICAL GENERAL NOTES

A. REPAIR/MAINTENANCE (K-WORK)

SCOPE OF WORK

NOTE :

M-2

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG YONGSAN-CASEY

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

GENERAL NOTES & SCOPE OF WORK

LIKE SHALL BE DONE BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE GOVERNMENT.

24. DISPOSAL OF CONSTRUCTION DEBRIS, WASTE MATERIALS, MATERIALS RESULTING FROM DEMOLITION ACTIVITIES, AND THE

WITHIN 1M OF THE UNIT.

23. ALL CONDENSATE DRAINS FROM COOLING UNIT (AS NOTED ON THE DRAWINGS) SHALL BE PROVIDED WITH SHUT-OFF VALVE

FLUSHED IS CLEAR AS TAP WATER.

22. PIPING SYSTEM SHALL BE FLUSHED, PURGED & CLEANED PER SPECS REQUIREMENTS AND FLUSHED UNTIL ALL WATER BEING

ALL ROUND DUCT TAKE-OFFS FROM SQUARE OR RECTANGULAR MAINS.

PROVIDE AIR SPLITTER DAMPERS AT ALL BRANCH TAKE-OFFS FROM THE MAIN DUCT. PROVIDE SPIN-IN TYPE FITTINGS AT

21. PROVIDE TURNING VANES IN ALL ELBOWS THAT CHANGE AIR DIRECTION MORE THAN 30 DEGREES OR USE RADIUS ELBOWS.

BODIES EXPOSED TO AIR BELOW THE FLOOR.

AIR CONDITIONING CONDENSATE DRAINS, OR ANY OTHER COLD LIQUID WHICH MAY CREATE CONDENSATION, FROM SINK

20. INSTALL CONDENSATE DRAINS AT A MINIMUM SLOPE OF 1/4 INCH PER 1 FOOT. INSULATE ALL SEWER PIPING RECEIVING

PROVIDE REMOTELY ACTUATED DAMPERS IN AREA WITH GYPBOARD OR CONCEALED CEILINGS.

COORDINATE THE LOCATION OF ACCESS PANELS TO INSURE THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.

AND FOR ANY ITEM INDISE DUCTS REQUIRING SERVICING OR INSPECTION 12"x12" ACCESS PANELS FOR TWO VALVES.

ALL AUTOMATIC CONTROL DAMPERS, FIRE DAMPERS, FIRE/SMOKE DAMPERS, DUCT SMOKE DETECTOR, BACKDRAFT DAMPERS

19. PROVIDE ACCESS PANELS TO ALL CONCEALED VALVES, DAMPERS, AND EQUIPMENT. PROVIDE ACCESS DOORS IN DUCTS AT

CALSS 500PA AND DUCTWORK SHALL MEET THE REQUIREMENTS OF SEAL CLASS C.

18. ALL SUPPLY, RETURN AND EXHAUST AIR DUCTWORK SHALL BE CONSTRUCTED ACCORDING TO SMACNA STATIC PRESSURE

TO THE COR FOR REVIEW AND APPROVAL.

MISCELLANEOUS PROJECTS, KOREA. THE HVAC TESTING, ADJUSTING AND BALANCING (TAB) REPORT SHALL BE SUBMITTED

WITH APPLICABLE SECTIONS OF DIVISION 22 & 23 - MECHANICAL. O & MA STANDARD TECHNICAL SPECIFICATIONS FOR

17. ALL MECHANICAL SYSTEMS SHALL BE TESTED, ADJUSTED AND BALANCED BY THE CONTRACTOR IN STRICT ACCORDANCE

CONTRACTING OFFICER FOR APPROAL.

PREPARED IN THE FIELD BY THE CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITIONS AND SUBMITTED TO THE

16. SOME DETAILS SHOWN ON THIS CONTRACT DRAWINGS MAY NOT MATCH EXACT FIELD CONDITIONS. SUCH DETAILS SHALL BE

DETAILS SHALL BE UTILIZED WHILE PERFORMING THE MECHANICAL SCOPE OF WORK.

15. FOR O & MA PROJECTS, KOREA, OCTOBER 1, 2003 DEPARTMENT OF THE ARMY FORM AS A PART OF THIS PROJECT. THE

OFFICER.

14. THE CONTRACTOR SHALL SUBMIT MANUFACTURERS INSTALLATION SHOP DRAWINGS FOR APPROVAL BY THE CONTRACTING

REPLACED BY THIS CONTRACTOR AT HIS OWN COST.

WORK, PIPING ETC. ANY DAMAGED DUE TO THE WORK PERFORMED UNDER THIS CONTRACT SHALL BE REPAIRED OR

13. CONNECTION TO EXISTING SYSTEM SHALL BE DONE IN SUCH A MANNER AS NOT DAMAGE ANY EXISTING EQUIPMENT, DUCT

EQUIPMENT AND ELECTRICAL ITEMS.

TO THE GOVERNMENT, INCLUDING, BUT NOT LIMITED TO ITEMS SUCH AS WALLS, CEILING, ROOF, PIPE, DUCT, ALLOW FOR INSTALLATION AND REPLACEMENT OF MECHANICAL AND FIRE PROTECTION SYSTEM AT NO ADDITIONAL COST

12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL AND REINSTALLATION OF ALL OBSTRUCTIONS AS NECESSARY TO

PROJECT AND TO MATCH CONDITION TO ADJACENT AREAS AT HIS OWN COST.

11. THE CONTRACTOR SHALL BE RESPONSIBLE TO CONSTRUCT OR REPAIR ALL DAMAGES TO EXISTING AREAS CAUSED BY THIS

EQUIPMENT PAD SIZE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.

10. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE CLEARANCE, COMMENCING ANY CONSTRUCTION OR RENOVATION.

9. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL EXISTING CONDITION AND DIMENSIONS PRIOR TO

8. ALL VALVES ON WET PIPE SYSTEM SHALL MEET NFPA 13 REQUIREMENT.

7. INSTALL SYSTEM TEST CONNECTION ON WET PIPE SYSTEM AND SHALL BE LOCATED AT THE MOST REMOTE BRANCH LINE.

6. SPRINKLERS WITH O-RINGS ARE NOT PERMITTED. PLUG TYPE TAMPER SWITCH SHALL NOT BE USED.

TO ALL RISER AND TRIM, SECTIONAL VALVES, INSPECTORS TEST VALVES, AND DRAINS.

5. PROVIDE LABEL TAG INDICATING "NORMALLY OPEN" OR "NORMALLY CLOSED" ON ALL VALVES INCLUDING AND NOT LIMITED

FLEXIBLE COUPLINGS, CLEARANCES, AND SEPARATION ASSEMBLIES.

PIPING AGAINST DAMAGE WHERE SUBJECT TO EARTHQUAKES". INCLUDING, BUT NOT LIMITED TO, SWAY BRACINGS,

4. PROVIDE ALL SEISMIC PROTECTION MEASURES FOR THE FIRE PROTECTION SYSTEM IAW NFPA 13 FOR "PROTECTION OF

PIPES LESS THAN 50 MM (2 INCHES) IN NOMINAL.

OF FLUID CARRIED AND DIRECTION OF FLOW. LABELS ARE NOT REQUIRED ON SPRINKLER SYSTEM BRANCH LINES AND

CONFORMING TO ASME/ANSI A13. 1-1996, "SCHEME FOR IDENTIFICATION OF PIPING SYSTEMS", INDICATING THE TYPE

3. MARK ALL EXPOSED INTERIOR PIPING AT 8 METER (26 FT) INTERVALS WITH PLASTIC WRAPAROUND TYPE PIPE LABELS

APPROVED FIRE STOPPING MATERIAL IAW SPECIFICATION 07 84 00.

2. THE CLEARANCES AROUND PIPE PENETRATION AT FIRE RATED WALLS AND/OR FLOOR SHALL BE PROPERLY SEALED WITH

UL LISTED AND/OR FM APPROVED IN ACCORDANCE WITH NFPA 13, NFPA 20 AND THE PROJECT SPECIFICATION.

COORDINATE SPRINKLER HEADS LOCATIONS WITH LIGHTING FIXTURES AND HVAC DEVICES. ALL EQUIPMENT SHALL BE

WITH APPLICABLE CODES, MANUFACTURER'S RECOMMENDATIONS, AND EQUIPMENT LISTINGS. THE CONTRACTOR SHALL

1. THE EQUIPMENT SHOWN ON THE PLAN ARE SUGGESTED LOCATIONS. FINAL LAYOUT SHALL BE VERIFIED AND IN ACCORDANCE

SWITCH WILL NOT BE IN EXCESS OF 61 METERS.

LEAST ONE SHUTOFF SWITCH PER FLOOR SO THAT THE TRAVEL DISTANCE TO THE NEAREST SHUTOFF

MOTORIZED DAMPER. LOCATION SHALL BE ADJACENT TO MANUAL FIRE ALARM PULL BOXES AND WITH AT

LABEL AS PER AT/FP REQUIREMENTS AND DISABLE THE FAN WHEN ACTIVATED AND CLOSE THE

9. THE BUILDING SHALL HAVE AN EMERGENCY SHUT DOWN SWITCH IN A CLEAR PLASTIC ENCLOSURE WITH

BY A LICENSED OR CERTIFIED INSTALLER.

8. INSTALLATION OF THE HVAC SYSTEM SHALL BE IN COMPLIANCE WITH MANUFACTURER'S SPECIFICATION

7. ANY PIPES THAT PENETRATE FIRE RATED WALL (EXISTING/ NEW) SHALL BE SEALED PER SPEC.

CONDUITS AND ALL NECESSARY ACCESSORIES FOR H.V.A.C CONTROLS.

6. THE MECHANICAL/CONTROLS CONTRACTOR SHALL PROVIDE ALL THE WIRINGS, RELAYS, CONTROLLERS, PROVIDE REMOTELY ACTUATED DAMPERS IN AREAS WITH GYPBOARD OR CONCEALED CEILINGS.

5. PROVIDE VOLUME DAMPERS ON DUCTWORK BRANCH LINES WHETHER SHOWN ON THE DRAWINGS OR NOT.

UL LISTED.

DAMPER RATINGS SHALL BE COMPATIBLE WITH THE FIRE WALL OR FLOOR. FIRE DAMPERS SHALL BE

4. PROVIDE FIRE DAMPERS AT ALL DUCT PENETRATIONS THROUGH FIRE RATED WALLS AND FLOORS. FIRE

TO ARCHITECTURAL DRAWINGS FOR CEILING TYPES.

3. PROVIDE DIFFUSERS AND GRILLE FRAMES COMPATIBLE WITH ARCHITECTURAL CEILING TYPES. REFER

THE CONTRACTING OFFICER.

2. THE CONTRACTOR SHALL SUBMIT MECHANICAL SYSTEM INSTALLATION SHOP DRAWINGS FOR APPROVAL BY

CLEARANCE, INSTALLATION LOCATIONS, AND ADDITIONAL ITEMS.

1. THE CONTRACTOR SHALL VERIFY EXISTING CONDITIONS FOR NEW WORK SUCH AS EQUIPMENT & SERVICE

TEST SHALL BE PERFORMED BY THE FPE (FIRE PROTECTION PROFESSIONAL ENGINEER).

7. THE CONTRACTOR SHALL INSPECT AND TEST THE FIRE PROTECTION SYSTEM. THE WORK INSPECTION AND

SYSTEM, SPARE SPRINKLER HEAD CABINET WITH SPARE SPRINKLER HEAD (6 EA) AS SHOWN ON DRAWINGS.

6. REPAIR THE SPRINKLER SYSTEM BY INSTALLING NEW AUTOMATIC FIRE PROTECTION WET SPRINKLER

CONTROL, ACCESS DOORS, AND ALL ASSOCIATED ACCESSORIES AS SHOWN ON DRAWINGS.

HOT WATER CIRCULATING PUMP, ELECTRIC WATER COOLERS, VALVES, WATER HAMMER ARRESTERS, HEATER, DOMESTIC HOT WATER STORAGE TANK, DOMESTIC HOT WATER RECIRCULATION PUMP, DOMESTIC

SEWER AND VENT PIPING SYSTEM INCLUDING PLUMBING FIXTURES, WASHER BOX, DOMESTIC HOT WATER

5. REPAIR THE PLUMBING SYSTEM BY INSTALLING NEW DOMESTIC COLD AND HOT WATER PIPING SYSTEM, OPERATIONAL, SUCH AS EQUIPMENTS AND CONTROLS.

4. PERFORM COMMISSIONING AFTER CONSTRUCTION TO VERIFY THAT THE H.V.A.C SYSTEM IS FULLY

CONSTRUCTION TO VERIFY THAT THE HVAC SYSTEM WORKS PROPERLY.

3. PERFORM DALT (DUCT AIR LEAKAGE TEST) AND T.A.B (TESTING, ADJUSTING, AND BALANCING) AFTER

AND ALL ASSOCIATED ACCESSORIES FOR HVAC SYSTEM AS SHOWN ON DRAWINGS.

EMERGENCY HVAC SHUT-OFF SWITCH, DUCTS, PIPES, INSULATIONS, ACCESS DOORS, EQUIPMENT SUPPORT, PUMP UNIT, OUTSIDE AIR UNITS, RANGE HOOD, CONTROLS, DIFFUSERS, GRILLES, LOUVERS, DAMPERS,

2. REPAIR THE VENTILATION SYSTEM BY INSTALLING NEW EXHAUST FANS, OUTDOOR SPLIT SYSTEM HEAT

FOR HVAC SYSTEM AS SHOWN ON DRAWINGS.

CONTROLS, ACCESS DOORS, EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES

FINNED TUBE RADIATOR, UNIT HEATER, AIR SEPARATORS, DUCTS, PIPES, VALVES, INSULATIONS, AIR HANDLING UNITS, FAN COIL UNITS, SPLIT AIR CONDITIONING UNIT, EXPANSION TANKS, PUMPS,

1. REPAIR THE HEATING AND COOLING SYSTEM BY INSTALLING NEW WATER CHILLER, HOT WATER BOILER, ITEM NO

Q'TY SERVICE TYPE

1/3

E Q U I P M E N T S C H E D U L E S - 1

REMARKS

M-3

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

EQUIPMENT SCHEDULES - 1

NOTE :

REQUIRMENTS.

ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT

THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING

QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY,

HOT WATER BOILER

B

BUILDING

ENTIRE

FIRED FIRE-TUBE

PACKAGED OIL

(LPH)

FIRING RATE

22.7

(Kw)

GROSS INPUT

OIL BURNER MOTOR

HP VOLT/PH/HZ

115/1/60 82.2

(°C)

SUPPLY TEMP

(kPa)

WORKING PRESS

ITEM NO Q'TY TYPE

Q'TY VOLT/PH/HZ

REMARKS

WATER CHILLER

WATER CHILLER

AIR-COOLED

(TON)

CAPACITY

COOLING

GPM

(°C)

EWT

(°C)

LWT

COMPRESSORS

Q'TY VOLT/PH/HZPOWER

CONDENSER FAN

POWER

INPUT

WC

REFTRIGERANT

ITEM NO Q'TY SERVICE TYPE

EF

EF

EF

EF

EF

EXHAUST FANS

REMARKS

1 4

HP VOLT/PH/HZ

115/1/60

FAN MOTOR

115/1/60

115/1/60

1/15 115/1/60

1/12 115/1/60

RPM

1,550

1,550

62.3

62.3

74.7

ITEM NO Q'TY SERVICE TYPE

P

REMARKS

HP VOLT/PH/HZ

208/3/60

FAN MOTOR

115/1/60

208/3/60

RPM

PUMPS

CENTRIFUGAL TYPE

BASE MOUNTED END SUCTION

CENTRIFUGAL TYPE

PIPE MOUNTED IN-LINE

CENTRIFUGAL TYPE

PIPE MOUNTED IN-LINE

1,750

1,750

1,750

CONSTRUCTION

ALL BRONZE

CONSTRUCTION

ALL BRONZE

ITEM NO Q'TY SERVICE TYPE

ET

ET

EXPANSION TANK

BLADDER TYPE

BLADDER TYPE

REMARKS

(mm DIA x mm HEIGHT)

TANK SIZE

500 x 1,050

(LPS)

CAP.

198.2

141.5

(LPS)

CAP.

AIR

ITEM NO Q'TY

AS

AIR SEPARATOR

REMARKS

INLET OUTLET

SERVICE TYPE

PIPE MOUNTED

PIPE SIZE

80 DIA WITH STRAINER

23.6

CHILLED WATER SYSTEM

HOT WATER SYSTEM

208/3/60

CENTRIFUGAL TYPE

BASE MOUNTED END SUCTION

1,750

ET

30350 x 775

AS

PIPE MOUNTED WITH STRAINER

HOT WATER SYSTEM

CHILLED WATER SYSTEM

80 DIA

P

P

P

CIRC. PUMP

CHILLED WATER

CIRC. PUMP

DOMESTIC HOT WATER

RECIRC. PUMP

DOMESTIC HOT WATER

5.92

1.26

1.70

(kPa)

HEAD

185.4

44.8

134.5

1/4

1-1/2

(Pa)

ESP

1,550

45Watts

1/4

1/10

1 2 3

1 2 3

1 2 3 5

1 2 3

1 W/BACKDRAFT DAMPER 2 W/DISCONNECT SWITCH 3 BIRD SCREEN 4 CEILING GRILLE 5 PREFABRICATED ROOF CURB.

CIRC. PUMP

HOT WATER

W/VIBRATION ISOLATOR

VARIABLE FREQUENCY DRIVE

W/VIBRATION ISOLATOR

VARIABLE FREQUENCY DRIVE

FOR MECH ROOM

FOR LAUNDRY ROOM

124.5

DIAPHRAGM TYPE

80 DIA 80 DIA

ITEM NO Q'TY SERVICE TYPE

FAN COIL UNIT

FLOOR MTD. TYPE

VERTICAL CABINET

NOTE

HP VOLT/PH/HZ

115/1/60

115/1/60

115/1/60

(LPS)

CAPACITY

AIR

DB WB

COOLING COIL

LPS

(°C)

EWT

(kPa)

MAX WPD

HEATING COIL

(°C)

EAT

(°C)

EWT

82.2

FCU

FCU

FCU

EAT(°C)

16.9

SUPPLY FAN

292.6

FLOOR MTD. TYPE

VERTICAL CABINET

17.6

(Pa)

EPS

11.1

19.2

134.5

(Kw)

SENSIBLE

(Kw)

TOTAL

1.96 1.67

2.84

1.91

3.17

2.32

23.9

23.9

16.9

23.9

16.9

0.09

0.20

0.10

6.67

6.67

6.67

(KW)

HEAT CAP.

82.2

82.2

1/30

1/6

1/12193.5

1 115/1/602.7 0.76 23.9

16.9

0.02 6.67 0.32 20 82.2

FCU

-139.2

253.2 80%

2. MFR. "BURNHAM" MODEL OR APPROVED EQUAL.

1. BOILER FUEL BURNING EQUIPMENT SHALL BE COMPATIBLE WITH BOTH DFW & JP-8 FUELS.

EFFICIENCY

MIN.

208/3/60 R-410A

12 7 208/3/60 4 900W x 4

101.8 KW

32.4

32.4

86.4

86.4 4 4 900W x 4

ITEM NO

AHU

Q'TY SERVICE TYPE

LPS

HP VOLT/PH/HZ

MOTOR

AIR HANDLING UNIT

198.2

REMARKS

HEATING COILCOOLING COILSUPPLY FAN

EAT(°C)

DB WB

LAT(°C)

DB WB

14.4

LPS EWT(°C)

82.1

EAT(°C)

LAT(°C)

100%115/1/60

SETTING

O.A

(KW)

TOTAL

8.50 -15.530.5

26.1

15.3 0.19

(KW)

TOTAL

(KW)

SENSIBLE

6.72 2.66

TEMP (°C)

ENT.WATER

7.2

(Pa)

ESP

1/3

CEILING MOUNTED

CONCEALED HORIZONTAL

OUTSIDEAIR MAKE-UP

LANUDRY RM

2. MFR. "MAGIC AIRE" MODEL 24HBAW-4 OR APPROVED EQUAL.

1. COIL CAPACITY SHALL BE BASED ON THE COOLING REQUIREMENTS.

PURPOSE ROOM(114A)

BED ROOMS & MULTI

RM 103,110,111,112

315,415) & LOUNGE

MULTI PURPOSE RM(114B,

FLOOR MTD. TYPE

VERTICAL CABINET

FLOOR MTD. TYPE

VERTICAL CABINET

0.62

- 2.4

0.94

0.59

1/30

1 115/1/60

CP

2.2 124.1 1.7FLA

COMM. ROOM

ONLY 1ST FL

LIFT PUMP

CONDENSATE DRAIN

10.76 188

7.5

1,132.4

188.7

74.7

FOR BATH ROOM & JAN

FOR BATH ROOM

FOR TOILET

DIRECT DRIVEN, CENTRIFUGAL

IN-LINE DUCT MOUNTED TYPE,

DIRECT DRIVEN, CENTRIFUGAL

ROOF MOUNTED TYPE,

DIRECT DRIVEN, CENTRIFUGAL

IN-LINE DUCT MOUNTED TYPE,

BELT DRIVEN, CENTRIFUGAL

IN-LINE DUCT MOUNTED TYPE,

DIRECT DRIVEN, W/HEAT LAMP

CEILING MOUNTED,

500 x 1,525

HOT WATER SYSTEM

DOMESTIC

(LITS)

VOLUME

ACCEPTANCE

(PSI)

PRESSURE

MAX. WORKING

=12 PSI

CHARGE PRESSURE

=12 PSI

CHARGE PRESSURE

8 115/1/6037.4 5.63 23.9

16.9

0.16 6.67 1.99 20 82.2

FCU

-236.0 5.33

MOUNTED TYPE

HORIZONTAL CEILING

1/3

CORRIDOR

1st,2nd,3rd & 4th FL.

C.O(116)

2. MFR. "LG ELEC" MODEL NO. ACAH033VETB & ACAH033VETB OR APPROVED EQUAL.

1. INVERTER SCROLL COMP., VIBRATION ISOLATOR, AHRI CERTIFIED & ETL LISTED, 3 YEARS WARRANTY.

6. 3 YEARS WARRANTY.

5. COIL CAPACITY SHALL BE BASED ON THE COOLING REQUIREMENTS.

4. W/ AIR DAMPER, W/ 20T FIBER GLASS FILTER.

ISOLATOR AS INDICATED ON DETAIL DWG.

3. EACH UNIT SHALL INCLUDE MANUFACTURER VALVE PACKAGE W/VIBRATION

2. UNIT SHALL BE PROVIDED WITH SUB-BASE AND COVER.

1. UL & AHRI 440 OR KC & KS B 6377 CERTIFIED PRODUCTS.

E Q U I P M E N T S C H E D U L E S - 2

ITEM NO Q'TY SERVICE TYPE

REMARKSVOLT/PH/HZ

NOTE :

REQUIRMENTS.

ACTUAL QUANTITIES BASED ON THE CONTRACT DOCUMENT

THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING

QUANTITIES ARE SHOWN FOR ESTIMATING PURPOSE ONLY,

ITEM NO Q'TY SERVICE TYPE

REMARKS

(LITS)

CAPACITY

TANK

DOMESTIC HOT WATER STORAGE TANK

ENTIRE BUILDING

HORIZONTAL TYPE

STEEL ROUND

(mmDIA x mmLONG )

TANK SIZE

1,650 x 3,475

CEMENT-LINED STEEL TANK, 150 PSI.

ASME CODE REQUIREMENTS COMPLETE,

7,570

208/1/60

M-4

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

EQUIPMENT SCHEDULES - 2

DT

ACU

COMM RM

AIR COOLED TYPE

PACKAGED SPLIT

(Kw)

CAPACITY

TOTAL

3.6 (1 TON)

(W)

POWER INPUT

1,150

2. ALL AC UNIT REFRIGERANT PIPING SHALL BE INSTALLED PERMANUFACTURER RECOMMENDATIONS.

1. EACH UNIT SHALL BE PROVIDED W/ WIRED REMOTE CONTROLLER.

ITEM NO Q'TY SERVICE TYPE

REMARKSVOLT/PH/HZ

208/3/6030,600

OUTDOOR SPLIT SYSTEM HEAT PUMP UNIT

OHPU

MULTI V TYPEALL OUTSIDE AIR UNITS

(BTU/HR)

CAPACITY

COOLING

TOTAL

(BTU/HR)

CAPACITY

HEATING

TOTAL

378,000

COMPRESSOR

HSS DC SCROLL x 4

(CFM)

FAN AIR FLOW

R-410A

REFTRIGERANT

1 2 3

1 COOLING CAPACITY SHALL BE BASED ON 35 DEG C 2 HEATING CAPACITY SHALL BE BASED ON 7 DEG C 3 MFR. "LG ELEC" MODEL NO. ARUN336BTE4 OR APPROVED EQUAL.

ITEM NO Q'TY SERVICE TYPE

REMARKSVOLT/PH/HZ

208/1/60 R-410A

REFTRIGERANT

1 COOLING CAPACITY SHALL BE BASED ON 35 DEG C 2 HEATING CAPACITY SHALL BE BASED ON 7 DEG C

OUTSIDE AIR UNIT

OAU

CEILING EMBEDDED TYPE

(BTU/HR)

CAPACITY

COOLING

(BTU/HR)

CAPACITY

HEATING

48,100 46,115

(CFM)

AIR FLOW RATE

(KW)

POWER INPUT

1 20.18

RATING

ELECTRICAL

336,000

180 AMP MOP

129 AMP MCA

SPLIT AIR CONDITIONING OUTDOOR & INDOOR UNIT

ITEM NO Q'TY SERVICE TYPE

REMARKS

(LITS)

CAPACITY

TANK

DOMESTIC HOT WATER HEATER

DWH

(°F)

RISE

TEMP.

100140

(°F)

TEMP.

SUPPLY

(LPH)

RECOVERY

HEAT

4,588

HP VOLT/PH/HZ

115/1/60

ELEMENT CAPACITY

1/3PACKAGED OIL FIRED TYPEDOMESTIC HOT WATER SYSTEM FUEL BURNING EQIPMENT SHALL BE COMPATIBLE WITH BOTH DFW & JP-8 MAX. WORKING PRESS. 150 PSI.

(LPH)

RATE

FIRING

33.7

ITEM NO Q'TY SERVICE TYPE

RH

REMARKS

1 2 32.5

VOLT/PH/HZ

115/1/60

FAN MOTOR

(CFM)

CAPACITY

FAN

RANGE HOOD

KITCHEN

HOOD VENTED TYPE

STAINLESS STEEL

AMPS

1 W/BACKDRAFT DAMPER 3 CHARCOL AND WASHABLE GREASE FILTER2 W/75 WATT LIGHTING

4 BUILT-IN CONTROL SWITCH.

(mm)

HOOD SIZE

750 X 500

ITEM NO Q'TY

ELECTRIC WATER COOLER

EWC

DESCRIPTION

SHALL CONFORM TO ADA/ARI STANDARD 1010.

REGULATOR W/BOTTLE FILLING STATION. MECHANICALLY AIR COOLED WITH AIR COOLED CONDENSER & COMPRESSOR

WALL MOUNTED TYPE, BUBBLER SHAL BE ACTIVATED BY DEPRESSING EITHER PUSH PADS AND BUILT-IN PRESSURE

MODEL

POWER

CAPACITY

: MFR. "ELKAY" MODEL LMABF8WS, OR APPROVED EQUAL.

: 4.0F.L.AMPS, 115 V, 1 PH, 60 HZ.

: 30.3 LPH, 32.2 DEC C TO 10 DEC C.

ITEM NO Q'TY SERVICE

REMARKS

FTR

82.2

(°C)

EWT

(LPS)

FLOW RATE

HOT WATER

(°C)

EAT

ROW

FINNED TUBE RADIATOR

0.02

ITEM NO Q'TY SERVICE TYPE

REMARKS

DISCHARGE TYPE

HORIZONTAL

VOLT/PH/HZ

FAN CAPACITY

LPS

256.2 1,550

RPM HP

1/20

UNIT HEATER

UH

LPS

10.0

(°C)

EWT

(°C)

EAT

0.05 82.1 115/1/60MECH RM (123)

(Kw)

CAPACITY

HEATING

2.3

STORAGE

(KW)

CAP.

HEATING

0.73 15.6

(mm)

LENGTH

ELEMENT

3 208/1/60 R-410A

OAU

CEILING EMBEDDED TYPE 95,900 91,360 1 20.362nd FL, 3rd FL AND 4th FL

708/477/4771st FL BED ROOM

1,260/837/837

4. 3 YEARS WARRANTY.

3. MFR. "LG ELEC" MODEL NO. SW09BAJWAS OR APPROVED EQUAL.

/ MFR. "LG ELEC" MODEL NO. ARNU483B8Z4 OR APPROVED EQUAL. 3 YEARS WARRANTY.

/ MFR. "LG ELEC" MODEL NO. ARNU963B8Z4 OR APPROVED EQUAL. 3 YEARS WARRANTY.

/ 3 YEARS WARRANTY.

- M5

1 EXISTING AND REMOVAL MECHANICAL PLAN

NOT TO SCALE

M-5

NTS

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

MECHANICAL PLAN

EXISTING AND REMOVAL

THIRD FLOOR

SECOND FLOOR

FIRST FLOOR

FOURTH FLOOR

UP

UP

D

D

D

W

W

UPDN

UPDN

REF

D

D

D

W

W

UPDN

UPDN

D

D

D

W

W

DN

DN

D

D

D

W

W

CONTROLS, EQUIPMENT SUPPORT (CONC. PAD), AND ALL ASSOCIATED ACCESSORIES.

PIPES, VALVES, DIFFUSERS, GRILLES, LOUVERS, DAMPERS, INSULATIONS,

ELECTRIC WATER COOLERS, VALVES, WATER HAMMER ARRESTERS, DUCTS,

HOT WATER RECIRCULATION PUMP, DOMESTIC HOT WATER CIRCULATING PUMP,

HOT WATER HEATER, DOMESTIC HOT WATER STORAGE TANK, DOMESTIC

PIPING SYSTEM INCLUDING PLUMBING FIXTURES, WASHER BOX, DOMESTIC

DOMESTIC COLD AND HOT WATER PIPING SYSTEM, SEWER AND VENT

PUMPS, ELECTRIC HEATERS, UNIT HEATER, EXHAUST FANS, RANGE HOOD,

SPLIT AIR CONDITIONING UNIT, EXPANSION TANKS, AIR SEPARATOR,

AIR HANDLING UNITS, FAN COIL UNITS, FINNED TUBE RADIATOR,

REMOVE EXISTING DETERIORATED WATER CHILLER, HOT WATER BOILER,

SACLE = 1:100

M-6

GRAPHIC SCALE

SCALE: 1:100

0 2000 4000

NEW H.V.A.C PLAN (1st FLOOR) M6

C.O

STAIR-1

119A

LAUNDRY

VEST

MECH ROOM

MULTI-PURPOSE RM

114B

STORAGE

ROOM

SPRINKLER

MULTI-PURPOSE RM

114A

CORRIDOR

MALE

113A

COMMO SHOP

STORAGE

VEST

ROOM

COMMUNITY ADMIN OFFICE

NBC ROOM

SUPPLY ROOM

COMM

XO

CO

STORAGE

106C

STORAGE

105A

R.O

106B

T.O

106A

STAIR-2

119B

102B

BED ROOMBED ROOM

102A

BED ROOM

101B

BED ROOM

101A

,9

,6

,9

,4

61,169

11,557 3,784 7,620 7,620 7,620 7,620 4,878 3,327 3,204 3,939

C

H W

R

C

H W

S

D

C

H W

R

C

H W

S

D

C

H W

R

C

H W

S

D D

C

H W

R

C

H W

S

D

C

H W

R C

H W

S D

C

H W

R C

H W

S D

C

H W

R C

H W

S D

C

H W

R C

H W

S D

C

H W

R C

H W

S D

C

H W

R C

H W

S D D

D D D

D D D D DD

C

H W

S C

H W

R

T

T

T

T T T

C

H W

R

C

H W

S

D

C

H W

R

C

H W

S

D

C

H W

R

C

H W

S

D

C

H W

R

C

H W

S

D

C

H W

R

T

C

H W

R

C

H W

S

D D

JAN

COMM RM

WAIT AREA

FEMALE

113B

100100 40

UNIT NO.

EQUALIZING DEFLECTOR

S-1

FUNCTION TYPE TYPE REMARKSFINISHMATERIAL ACCESSORIES

1 2 3

AIR DEVICE SCHEDULE

S-2 REGISTER 1 4 7

R-1 REGISTER 1 4 5

E-1 EXHAUST REGISTER 1 4 5

E-2 EXHAUST 1 4 5

SUPPLY

SUPPLY

RETURN

GRILLE

4 6

WHITE ENAMEL

SQUARE DIFFUSER ALUMINUM

ALUMINUM

ALUMINUM

ALUMINUM

ALUMINUM

OPPESED BLADE DAMPER

FIXED 3/4" HORIZENTAL BARS 45° DEFLECTION

4-WAY THROW UNLESS OTHERWISE INDICATED

FACE BARS

DOUBLE DEFLECTION REGISTER WITH HORIZENTAL

PLASTER CEILINGS.

STANDARD FOR SURFACE MOUNTED UNITS ON

DIFFUSER PANELS SHALL BE THE MANUFACTURERS

ARCH. DWG. FOR CEILING TYPE. DIMENSIONS OF

MOUNTING IN SUSPENDED TILE CEILING SEE

NOMINAL 24"x24" 3-CONE DIFFUSER FOR

T

C

H W

R

C

H W

S D

C

H W

R

C

H W

S

D

T

D

E A

E A

FCU

CH

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

FCU

CH

FCUCH

CH

29 1

FCU

FCUCH

27 1

FCUCH

26 3

FCUCH

CH

CH

CH

EA

EA

SEE

SEE

FCU

FCU

(OUTDOOR UNIT)

SPLIT TYPE A/C UNIT

ACU

(INDOOR UNIT)

SPLIT TYPE A/C UNIT

ACU

THERMOSTAT(TYP)

HEATING & COOLING

COMBINATION TYPE

FCU

SEE (TYP)

300x200

150x200

RA : 750x200

SA : 500x150

SA : 600x200 x

600x200

250x150

250x150

250x150

250x150

300x150 300x150

700x150

250x100 x

700x150 700x150

500x150 x

500x150

250x150

250x100

250x150

250x150250x150250x150

250x150

68 LPS

R-1:600x100

64 LPS

R-1:600x100

64 LPS

R-1:600x100

118 LPS

R-1:600x100

92 LPS

R-1:600x100

68 LPS

S-1:200

64 LPS

S-1:200 x3

70 LPS

S-1:200

46 LPS

S-1:200 x2 x2

59 LPS

S-1:200

W/SPLASH BLOCK (TYP)

AND SPILL ON GRADE

40 DIA COND. DRAIN DROP

76 LPS

R-1:600x100 x2

41 LPS

S-1:200

38 LPS

S-1:200 x2

76 LPS

R-1:600x100

W/SPLASH BLOCK (TYP)

AND SPILL ON GRADE

40 DIA COND. DRAIN DROP

RELIEF LOUVER

1,000x400

SEE

EXHAUST AIR LOUVER

150x100

EXHAUST AIR LOUVER

600x200

250x250

150x100

EF

EXHAUST FAN

EF

EXHAUST FAN

56 LPS

E-1:200x150

83 LPS

E-1:300x200 250x100

JAN

200x100

NOTE :

4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

PIPING SHALL BE COPPER PIPING.

3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

UP

UP

D

D

W

W

1:100

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

NEW H.V.A.C PLAN (1st FLOOR)

- M12

- M12

- M12

- M11

M-7

GRAPHIC SCALE

SCALE: 1:100

0 2000 4000

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

SACLE = 1:100

NEW H.V.A.C PLAN (2nd FLOOR) M7

LAUNDRY

JAN

LOUNGE

219CORRIDOR

BED ROOM

201A

BED ROOM

201B

BED ROOM

202A

BED ROOM

202B

BED ROOM

203A

BED ROOM

203B

BED ROOM

204A

BED ROOM

204B

BED ROOM

205A

BED ROOM

205B

BED ROOM

206A

BED ROOM

206B

BED ROOM

207A

BED ROOM

207B

BED ROOM

208A

BED ROOM

208B

BED ROOM

214A

BED ROOM

214B

BED ROOM

213A

BED ROOM

213B

BED ROOM

212A

BED ROOM

212B

BED ROOM

211A

BED ROOM

211B

BED ROOM

210A

BED ROOM

210B

BED ROOM

209A

BED ROOM

209B

STAIR-2

218B

STAIR-1

218A

,9

,6

,9

,4

SACLE = 1:100

NEW H.V.A.C PLAN (3rd FLOOR) M7

BED ROOM

301A

BED ROOM

301B

BED ROOM

302A

BED ROOM

302B

BED ROOM

303A

BED ROOM

303B

BED ROOM

304A

BED ROOM

304B

BED ROOM

305A

BED ROOM

305B

BED ROOM

306A

BED ROOM

306B

BED ROOM

307A

BED ROOM

307B

BED ROOM

308A

BED ROOM

308B

319CORRIDOR

JAN

LAUNDRY

PURPOSE RM

MULTI

BED ROOM

314A

BED ROOM

314B

BED ROOM

313A

BED ROOM

313B

BED ROOM

312A

BED ROOM

312B

BED ROOM

311A

BED ROOM

311B

BED ROOM

310A

BED ROOM

310B

BED ROOM

309A

BED ROOM

309B

STAIR-2

STAIR-1

318A

,9

,6

,9

,4

FCU

CH

CH

FCU

CH

FCU

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

R

C

H W

S

T

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S

C

H W

R

C

H W

R C

H W

S

D

C

H W

R D

C

H W

S

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

C

H W

R

C

H W

S

D

T T

C

H W

R

C

H W

S D

E A

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

D

C

H W

R

C

H W

S

D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

D

C

H W

R C

H W

S D

T

D

C

H W

R

C

H W

S

D

D

C

H W

R

C

H W

S

D

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

D

C

H W

R

C

H W

S

D

D

C

H W

R

C

H W

S

D

D

C

H W

R

C

H W

S

D

D

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

C

H W

S

D C

H W

R

C

H W

R

C

H W

S

D

D

C

H W

R C

H W

S D

D

C

H W

R C

H W

S D

D

C

H W

R C

H W

S D

D

C

H W

R C

H W

S D

D

C

H W

R C

H W

S D

D

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

S D

C

H W

R

C

H W

R C

H W

S D

C

H W

R

C

H W

S

C

H W

R

C

H W

R C

H W

S C

H W

R

C

H W

S

D

C

H W

R D

C

H W

S

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

T

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

D C

H W

R

C

H W

S

C

H W

R

C

H W

S

D

T

CH

CH

EA

EA

1 EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

FCU

FCU

THERMOSTAT(TYP)

HEATING & COOLING

COMBINATION TYPE

SEE

SEE

SEE

SEE

FCU

CH

CH

FCU

CH

FCU

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

FCU

CH

CH

CH

EA

EA

1 EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

FCU

FCU

THERMOSTAT(TYP)

HEATING & COOLING

COMBINATION TYPE

SEE

SEE

SEE

SEE

SEE

SEE 1

RH

W/ WALL CAP

RANGE HOOD

NOTE :

4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

PIPING SHALL BE COPPER PIPING.

3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

UPDN

UPDN

REF

D

D

W

W

UPDN

UPDN

REF

D

D

W

W

1:100

NEW H.V.A.C PLAN (2nd & 3rd FLOOR)

- M12

- M12

- M12

- M12

- M12

- M12

- M12

- M12

- M12

- M12

NOTE ON INSTALLATION OF PIPE INSULATION :

THE INSTALLATION OF THE PIPE INSULATION IS COMPLETED.

4. THE CONTRACTOR SHALL INVITE THE MECH. ENGINEER FOR QUALITY INSPECTION WHEN

50 WHEN TESTED IN ACCORDANCE WITH ASTM E84.

A MAXIMUM FLAME SPREAD INDEX OF 25 AND A MAXIMUM SMOKE DEVELOPED INDEX OF

3. LAGGING ADHESIVES SHALL BE NONFLAMMABLE AND FIRERESISTANT AND SHALL HAVE

2. INSULATION MATERIALS RECOGNIZED UNDER UL94 AND LISTED IN FM APP GUIDE.

SHALL COMPLY WITH ASTM C534/C534M, GRADE 1, TYPE I OR II.

1. INSULATION MATERIALS SHALL CONFORM TO TABLE1 OF OMA SPEC 23 07 00, AND

LAUNDRY

JAN

PURPOSE RM

MULTI

419CORRIDOR

BED ROOM

414A

BED ROOM

414B

BED ROOM

413A

BED ROOM

413B

BED ROOM

412A

BED ROOM

412B

BED ROOM

411A

BED ROOM

411B

BED ROOM

410A

BED ROOM

410B

BED ROOM

409A

BED ROOM

409B

BED ROOM

401A

BED ROOM

401B

BED ROOM

402A

BED ROOM

402B

BED ROOM

403A

BED ROOM

403B

BED ROOM

404A

BED ROOM

404B

BED ROOM

405A

BED ROOM

405B

BED ROOM

406A

BED ROOM

406B

BED ROOM

407A

BED ROOM

407B

BED ROOM

408A

BED ROOM

408B

STAIR-2

418B

STAIR-1

418A

,9

,6

,9

,4

M-8

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

GRAPHIC SCALE

SCALE: 1:100

0 2000 4000

SACLE = 1:100

NEW H.V.A.C PLAN (4th FLOOR) M8

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

FCU

EF

EF

EF

EF

EF

EF

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

EA

50 65

BALANCING VALVE(TYP)

CIRCUIT SETTER SEE (TYP)

EF

(TYP OF 7)

EXHAUST FAN

50 65

250x150

250x150 250x250

250x150 250x150 250x150 250x150 250x150 250x150

250x250 250x250 250x250 250x250 250x250

THERMOSTAT(TYP)

HEATING & COOLING

COMBINATION TYPE

(TYPICAL)

NEW PIPE ANCHOR

BELLOWS TYPE (TYP.)

NEW EXPANSION JOINT

(TYPICAL)

NEW PIPE GUIDE

SEE

SEE (TYP)

SEE

SEE

C

H W

S

D C

H W

R

C

H W

S D

C

H W

R

C

H W

R D

T

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S D

C

H W

R

C

H W

S

C

H W

R

C

H W

S

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

E A

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

D C

H W

R

C

H W

S

T

C

H W

R

C

H W

S D

T

D C

H W

R

C

H W

S

C

H W

R C

H W

S

C/HWR

C/HWS

C/HWR

C/HWS

C/HWR

C/HWS

C

H W

S C

H W

R

C/HWS

C/HWR

C/HWS

C/HWR

C/HWS

C/HWR

NOTE :

4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

PIPING SHALL BE COPPER PIPING.

3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN

DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

HVAC PIPING (HOT/CHILLED WATER PIPING AND

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

IN FIELD (TYP.).

AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

UPDN

UPDN

REF

D

D

W

W

61,169

7,721 7,620 7,620 7,620 7,620 7,620 7,620 7,729

NEW H.V.A.C PLAN (4th FLOOR)

1:100

- M12

- M12

- M12

- M12

- M12

M-9 1:100

GRAPHIC SCALE

SCALE: 1:100

0 2000 4000

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

NOTE :

DUCTWORK PRIOR TO DUCTWORK INSTALLATION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

C.O

STAIR-1

119A

LAUNDRY

JAN

VEST

MECH ROOM

MULTI-PURPOSE RM

114B

STORAGE

ROOM

SPRINKLER

MULTI-PURPOSE RM

114A

CORRIDOR

MALE

113A

COMMO SHOP

FEMALE

113B

STORAGE

VEST

ROOM

COMMUNITY

ADMIN OFFICE

NBC ROOM

SUPPLY ROOM

COMM

XO

CO

STORAGE

106C

WAIT AREA

STORAGE

105A

R.O

106B

T.O

106A

STAIR-2

119B

102B

BED ROOMBED ROOM

102A

BED ROOM

101B

BED ROOM

101A

LAUNDRY

JAN

LOUNGE

219CORRIDOR

BED ROOM

201A

BED ROOM

201B

BED ROOM

202A

BED ROOM

202B

BED ROOM

203A

BED ROOM

203B

BED ROOM

204A

BED ROOM

204B

BED ROOM

205A

BED ROOM

205B

BED ROOM

206A

BED ROOM

206B

BED ROOM

207A

BED ROOM

207B

BED ROOM

208A

BED ROOM

208B

BED ROOM

214A

BED ROOM

214B

BED ROOM

213A

BED ROOM

213B

BED ROOM

212A

BED ROOM

212B

BED ROOM

211A

BED ROOM

211B

BED ROOM

210A

BED ROOM

210B

BED ROOM

209A

BED ROOM

209B

JAN

STAIR-2

218B

STAIR-1

218A x

150x100

150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100150x100 150x100 150x100 150x100 150x100 150x100 150x100

150x100150x100150x100150x100150x100150x100150x100 150x100150x100150x100150x100150x100

VD VD

VDVD

VD

200x150

VD

VDVD

250x200VDVD 350x200VDVD

VDVD

500x250

VD

450x250

VD VD

400x250

VD VD

VD VD

350x250VDVD

VDVD

VD VD

VD VD

500x250

,9

,6

,9

,4

OAU

OUTSIDE AIR UNIT

L P

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

SACLE = 1:100M9

,9

,6

,9

,4

61,169

11,557 3,784 7,620 7,620 7,620 7,620 4,878 3,327 3,204 3,939

"EMERGENCY HVAC SHUT-OFF SWITCH"

WITH CLEAR FLIP-COVERLABELLED AS

HVAC EMERGENCY SHUT-OFF SWITCH

COMM RM

NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (1st FLOOR)

SACLE = 1:100

NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (2nd FLOOR)

(1st & 2nd FLOOR)

NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM

x

OAU

OUTSIDE AIR UNIT

"EMERGENCY HVAC SHUT-OFF SWITCH"

WITH CLEAR FLIP-COVERLABELLED AS

HVAC EMERGENCY SHUT-OFF SWITCH

S x

150x100150x100

S x

150x100

S x

S x

150x1002

S x

S x

S x

S x

S x

S x

S x

VD

VD

150x100VD200x150 VD

VD

VD

VDVD

250x200 200x100350x200 VD

VDVD

x

400x200

OHPU

HEAT PUMP UNIT

SPLIT SYSTEM

OUTDOOR

NEW CONC. PAD

UP

UP

D

D

W

W

UPDN

UPDN

REF

D

D

W

W

M9

LAUNDRY

JAN

PURPOSE RM

MULTI

419CORRIDOR

BED ROOM

414A

BED ROOM

414B

BED ROOM

413A

BED ROOM

413B

BED ROOM

412A

BED ROOM

412B

BED ROOM

411A

BED ROOM

411B

BED ROOM

410A

BED ROOM

410B

BED ROOM

409A

BED ROOM

409B

BED ROOM

401A

BED ROOM

401B

BED ROOM

402A

BED ROOM

402B

BED ROOM

403A

BED ROOM

403B

BED ROOM

404A

BED ROOM

404B

BED ROOM

405A

BED ROOM

405B

BED ROOM

406A

BED ROOM

406B

BED ROOM

407A

BED ROOM

407B

BED ROOM

408A

BED ROOM

408B

STAIR-2

418B

STAIR-1

418A x

150x100

150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100150x100 150x100 150x100 150x100 150x100 150x100 150x100

150x100150x100150x100150x100150x100150x100150x100 150x100150x100150x100150x100150x100

VD VD

VDVD

VD

200x150

VD

VDVD

250x200VDVD 350x200VDVD

VDVD

500x250

VD

450x250

VD VD

400x250

VD VD

VD VD

350x250VDVD

VDVD

VD VD

VD VD

500x250

M-10 1:100

GRAPHIC SCALE

SCALE: 1:100

0 2000 4000

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

NOTE :

DUCTWORK PRIOR TO DUCTWORK INSTALLATION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR

AND DIRECTION OF DUCTWORKS IN FIELD (TYP.).

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE

,9

,6

,9

,4

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

BED ROOM

301A

BED ROOM

301B

BED ROOM

302A

BED ROOM

302B

BED ROOM

303A

BED ROOM

303B

BED ROOM

304A

BED ROOM

304B

BED ROOM

305A

BED ROOM

305B

BED ROOM

306A

BED ROOM

306B

BED ROOM

307A

BED ROOM

307B

BED ROOM

308A

BED ROOM

308B

319CORRIDOR

JAN

LAUNDRY

PURPOSE RM

MULTI

BED ROOM

314A

BED ROOM

314B

BED ROOM

313A

BED ROOM

313B

BED ROOM

312A

BED ROOM

312B

BED ROOM

311A

BED ROOM

311B

BED ROOM

310A

BED ROOM

310B

BED ROOM

309A

BED ROOM

309B

STAIR-2

STAIR-1

318A

61,169

7,721 7,620 7,620 7,620 7,620 7,620 7,620 7,729

,9

,6

,9

,4

150x100

150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100 150x100150x100 150x100 150x100 150x100 150x100 150x100 150x100

150x100150x100150x100150x100150x100150x100150x100 150x100150x100150x100150x100150x100

VD VD

VDVD

VD

200x150

VD

VDVD

250x200VDVD 350x200VDVD

VDVD

500x250

VD

450x250

VD VD

400x250

VD VD

VD VD

350x250VDVD

VDVD

VD VD

VD VD

500x250

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x

S x x

"EMERGENCY HVAC SHUT-OFF SWITCH"

WITH CLEAR FLIP-COVERLABELLED AS

HVAC EMERGENCY SHUT-OFF SWITCH

"EMERGENCY HVAC SHUT-OFF SWITCH"

WITH CLEAR FLIP-COVERLABELLED AS

HVAC EMERGENCY SHUT-OFF SWITCH

SACLE = 1:100

NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (4th FLOOR)

SACLE = 1:100

NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM (3rd FLOOR)

(3rd & 4th FLOOR)

NEW H.V.A.C PLAN FOR D.O.A.U SYSTEM

OAU

OUTSIDE AIR UNIT

OAU

OUTSIDE AIR UNIT

UPDN

UPDN

REF

D

D

W

W

UPDN

UPDN

REF

D

D

W

W

M10

M10

M-11

MECHANICAL

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

M11 SACLE = 1:50

MECHANICAL ROOM ENLARGED PARTIAL PLAN

ET

DOMESTIC H.W SYSTEM

EXPANSION TANK FOR

ET

CHILLED WATER SYSTEM

EXPANSION TANK FOR

ET

HOT WATER SYSTEM

EXPANSION TANK FOR

EF

EXHAUST FAN

UH

UNIT HEATER

REDUCING VALVE

PRESSURE

AS

HOT WATER SYSTEM

AIR SEPARATOR FOR

AS

CHILLED WATER SYSTEM

AIR SEPARATOR FOR

P

CIRCULATION PUMP

DOMESTIC HOT WATER

P

RECIRCULATION PUMP

DOMESTIC HOT WATER

WC

WATER CHILLER

DRAN PIT

C.O

VEST

MECH ROOM

C.O

MECH ROOM

VEST

NOTE :

WITH THE MANUFACTURER'S RECOMMENDATIONS.

3. THE DIAMETER OF THE SMOKE STACK IS IN ACCORDANCE

DOMESTIC WATER PIPING PRIOR TO PIPING INSTALLATION.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC &

DIRECTION OF PIPING IN FIELD (TYP.).

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND

FLEXIBLE CONNECTOR (TYP.)

THERMOSTAT (TYP.)

FLOW SWITCH

DT

STORAGE TANK

DOMESTIC HOT WATER

FOR PLUMBING PIPINGFOR H.V.A.C PIPING

FCU

FAN COIL UNIT

P

CIRCULATION PUMP

HOT WATER

P

CIRCULATION PUMP

CHILLED WATER

TO REMAIN

AIR HANDLING UNIT

EXISTING

DWH

HOT WATER HEATER

DOMESTIC

BOOSTER PUMP TO REMAIN

EXISTING DOMESTIC WATER

P.O.C

P.O.C

P.O.C

P.O.C

TO REMAIN

LOUVER W/ DUCT

EXISTING

750x200(E)

750x200(N)

FD

32(E)32(N)

100,100,40

FD

FD

600x200(N) x

E x

E

500x150(N)

(TYP)

FEEDER

CHEMICAL

20,20

(TOP & BOTTOM LEVEL)

INTAKE LOUVER

& COMBUSTION AIR

600x600 O.A. INTAKE

HEATING THERMOSTAT

(FOR HEATING SYSTEM)

OUTDOOR AIR THERMOSTAT

(FOR COOLING SYSTEM)

OUTDOOR AIR THERMOSTAT

60°C

43.3°C

S V

V S

FOS

FOR

FOR

FOS

(UNDERGROUND PIPING)

100,100

THERMOSTAT FOR EF-2

VENTINATION

BAROMETRIC DAMPER (TYP)

300 DIA SMOKE STACK WITH

BAROMETRIC DAMPER (TYP)

250 DIA SMOKE STACK WITH

CONTROL VALVE

MODULATING 3-WAY

D D

MD

C W

S

C W

R

C W

S

C W

R

CWS

CWR

HT

VTOTOT

EXHAUST AIR GRILLE

1,100x700

750x300

I N

T A

K E

O

U V

E R x

A

B

HOT WATER BOILER

E

A

U V

E R x

50 FD

50 FD

100 FCO

PREVENTER

BACK-FLOW

WATER METER

65mm

FD

3-WAY MIXING VALVE

THERMOSTATIC

65,50,32,32

65,65,25

LINES

FUEL OIL

NEW

OIL FILTER (TYP)

BALL CHECK VALVE (TYP)

SHUT-OFF VALVE (TYP)

AUTO SAFETY

ENLARGED PARTIAL PLAN

MECHANICAL ROOM

1:50

SCALE: 1:50

0 1000 2000

GRAPHIC SCALE

M-12

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

M12

20 20

NEW H.V.A.C & H.V.A.C PIPING ENLARGED PARTIAL PLANS

SACLE = 1:50

SCALE: 1:50

0 1000 2000

GRAPHIC SCALE

BED ROOMBED ROOM

T T

VEST

LAUNDRY ROOM HVAC PARTIAL PLAN (TYP.)

M12 NOT TO SCALE

NEW H.V.A.C PIPING ISOMETRIC DIAGRAM

AS SHOWN

NEW H.V.A.C PIPING ISOMETRIC DIAGRAM

ENLARGED PARTIAL PLANS AND

NEW H.V.A.C & H.V.A.C PIPING

C

H W

S

C

H W

R

T S

W C

H

M

AHU

AIR HANDLING UNIT

O.A INTAKE LOUVER

600x200

198.2 LPS

S-2:400x400

450x200

450x200

EF

EXHAUST FAN

E.A LOUVER

600x200 200 DIA WALL VENT

E.A LOUVER

200x200

CONNECT TO VENT (TYP)

100 DIA DRYER VENT

150x100

198.2 LPS

E-2:400x400

EF

EXHAUST FAN

450x200

REMAIN (TYPICAL)

DRYER VENT TO BE

COND. DRAIN (TYP)

ACCESS DOOR

(1ST FL. ONLY)

FOR CONT. SEE

20 DIA COND, DRAIN

MODULATING 3-WAY CONTROL VALVE

CHWS & CHWR (TYP)

NOTE :

4. PROVIDE CEILING/WALL ACCESS PANEL FOR VALVES.

3. ALL HWS, HWR, C/HWS, C/HWR & CONDENSATE DRAIN PIPING SHALL BE COPPER PIPING.

2. CONTRACTOR SHALL SUBMIT SHOP DRAWING FOR HVAC PIPING (HOT/CHILLED WATER PIPING AND DRAIN PIPING) PRIOR TO HVAC PIPING INSTALLATION.

1. CONTRACTOR SHALL VERIFY EXACT LOCATION, SIZE AND DIRECTION HOT/CHILLED WATER AND DRAIN PIPING IN FIELD (TYP.).

NEW TYP MODULE HVAC PARTIAL PLAN

(1ST FLOOR)

NEW TYP MODULE HVAC PARTIAL PLAN

(2ND THRU 4TH FLOOR)

THERMOSTAT(TYP)

HEATING & COOLING

COMBINATION TYPE

F.D

EXHAUST DUCT RISER

250x150

EF

EXHAUST FAN

150x100

FCU

FAN COIL UNIT

FCU

20 (CHWR)

20 (CHWS)

25 (D)25 (D)

20 (CHWS)

20 (CHWR)

(TYPICAL)

SEE ARCH. DWG

PIPE ENCLOSURE

NOZZLE W/SPLASH BLOCK (TYP)

AND CONNECT TO DOWN SPOUT

40 DIA COND. DRAIN DROP

COND. DRAIN (TYP)

CHWS & CHWR &

T T

THERMOSTAT(TYP)

HEATING & COOLING

COMBINATION TYPE

F.D

EXHAUST DUCT RISER

250x150

EF

EXHAUST FAN

150x100

FCU

FAN COIL UNIT

FCU

20 (CHWR)

20 (CHWS)

25 (D)25 (D)

20 (CHWS)

20 (CHWR)

(TYPICAL)

SEE ARCH. DWG

PIPE ENCLOSURE

NOZZLE W/SPLASH BLOCK (TYP)

AND CONNECT TO DOWN SPOUT

40 DIA COND. DRAIN DROP

COND. DRAIN (TYP)

CHWS & CHWR &

SEE

4TH

FL

H

VAC

PLAN

AUTO

AI

R

VENT

1S T

FL

OOR

2ND

FL

OOR

4TH

FL

OOR

3RD

FL

OOR

1S T

FL

OOR

2ND

FL

OOR

4TH

FL

OOR

3RD

FL

OOR

C H

W S

C H

W R

D C

H W

S C

H W

R

DC

H

W S

C H

W R

D D

CHW

R

CHW

S

CHW

SCHW

R

SP

IL

L

OVER

SP

LAS

H

BLOCK

TO

DOW

N

SP

OUT

NOZZLE

A

ND

DI

A

COND.

D

RAI

N

CONNECT

SP

IL

L

OVER

SP

LAS

H

BLOCK

TO

DOW

N

SP

OUT

NOZZLE

A

ND

DI

A

COND.

D

RAI

N

CONNECT

HVAC

PLAN

SEE

4TH

FL

AUTO

AI

R

VENT

HVAC

PLAN

SEE

4TH

FL

BED ROOMBED ROOM

STAIR-1

119A

218A

318A

418A

JAN

UP

D

D

W

W

- M6

M-13

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A

B C D

E F G H

SHEET OF

M13 NOT TO SCALE

NEW H.V.A.C PIPING SCHEMATIC FLOW DIAGRAM - 1

NOTE :

WITH THE BALANCING VALVE INSTRUCTIONS.

TO CHILLED AND HEATING WATER FLOW RATES IN ACCORDANCE

THAT HAVE CIRCUIT SETTERS & BALANCE THE CIRCUIT SETTER

2. CONTRACTOR SHALL ADD ALL THE FLOW RATES ON THE LINES

1. HORIZONTAL PIPE LINE'S SIZES ARE SHOWN ON PIPING PLANS.

AUTO AIR VENT(TYP)

1ST FL

2ND FL

3RD FL

4TH FL

ROOF

FCU

FCU

FCU

FCU

114A

FCU

FCU

114A

FCU

FCU

114A

FCU

FCU

114A

FCU

FCU

FCU

FCU

FCU

FCU

AHU

AHU

AHU

AHU

40 20

40 25

32 32

CH

40100100

40100100

25100100

CH

BALANCING VALVE(TYP)

RISER CIRCUIT SETTER

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

CH

EXPANSION JOINT

BELLOWS TYPE

(TYPICAL)

AUTO AIR VENT

25 32

401A

FCU

FCU

401B

FCU

FCU

25 25

402A

FCU

FCU

25 25

402B

FCU

FCU

25 25

403A

FCU

FCU

25 25

406B

FCU

FCU

25 25

406A

FCU

FCU

25 25

405B

FCU

FCU

25 25

405A

FCU

FCU

25 25

404B

FCU

FCU

25 25

404A

FCU

FCU

25 25

403B

FCU

FCU

25 25

306B

FCU

FCU

40 25 25

306A

FCU

FCU

305B

FCU

FCU

305A

FCU

FCU

304B

FCU

FCU

304A

FCU

FCU

303B

FCU

FCU

303A

FCU

FCU

302B

FCU

FCU

302A

FCU

FCU

301B

FCU

FCU

301A

FCU

FCU

40 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 2540 25 32 40 25 25

206B

FCU

FCU

206A

FCU

FCU

205B

FCU

FCU

205A

FCU

FCU

204B

FCU

FCU

204A

FCU

FCU

203B

FCU

FCU

203A

FCU

FCU

202B

FCU

FCU

202A

FCU

FCU

201B

FCU

FCU

201A

FCU

FCU

40 25 2540 25 2540 25 2540 25 2540 25 25

100 100

50 50

C H

W R

C H

W S

C H

W R

C H

W S

C H

W R

C H

W S

C H

W R

C H

W S

D D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

CHWS

CHWR

D

CHWR

CHWR

CHWS

CHWR

CHWS

CHWR

CHWS

CHWR

CHWS

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

C H

W S

C H

W R

D C

H W

S C

H W

R

D

SCHEMATIC FLOW DIAGRAM - 1

NEW H.V.A.C PIPING

M-14

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON,…