A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

SCALE: 1/100

1ST FLOOR PLAN

90THK STL STUD WALL

LEGEND

A-1

ARCHITECTURAL

W/ MET STUD OR APPROVED EQUAL

5/8" THK TYPE "X" GWB & 1" THK TYPE "X"GWB

UL-DESIGN U469 (GA FILE NO 7008)

1 HR FIRE RATED STUD WALL

150THK STL STUD WALL

200THK STL STUD WALL

EXST CMU WALL TO REMAIN

W/FIBER GLASS INSULATION (STC 45 MIN.)

90THK, 150THK OR 200THK STL STUD WALL

EWC

E W

C

UP

UP

S/S

BED ROOM

101A

STORAGE

103 VEST

ROOM

ADMIN OFFICE

R.O

106B

T.O

106A

WAIT AREA

STORAGE

106C

STAIR-2

119B

CO

XO

COMM

SUPPLY ROOM

NBC ROOM

COMMO SHOP

MALE

113A

FEMALE

113B

JAN

113MULTI-PURPOSE RM

114MECH ROOM

C.O

VEST

STAIR-1

119A

LAUNDRY

JAN

CORRIDOR

105A

COMMUNITY

BED ROOM

101B

BED ROOM

102A

BED ROOM

102B

D

D

W

W

REFER TO

PARTIAL PLAN

SS

SS

61,169

3,9393,2043,3274,8787,6207,6207,6207,6203,78411,557

,4

,9

,6

,9

7,6485,5833,2532,538535 2,4402,8193,8121,8326,9085,5651,9307,7257,648

,0

,8

,6

,9

FEC OPENING

BLOCK-UP

FEC OPENING

BLOCK-UP

FEC

MULTI-PURPOSE RM

MANUFACTURES INDICATED.

PURPOSES ONLY. AND NOT INTENDED TO LIMIT SELECTIONS TO PRODUCTS OF THE

COLORS AND PATTERNS LISTED BY MANUFACTURES ARE FOR BIDDING IDENTIFICATION 1.

FOR APPROVAL.

CONTRACTOR ACCORDING TO ACTUAL FIELD CONDITION AND SUBMITED TO COR

CONDITION. IN THAT CASE, SHOP DRAWINGS SHALL BE PREPARED AT THE SITE BY THE

SOME DETAILS SHOWN ON CONTRACT DRAWINGS MAY NOT COINCIDE WITH THE FIELD

8.

FOR APPROVAL.

CONTRACTOR SHALL SUBMIT MANUFACTURER'S INSTALLATION SHOP DRAWINGS TO COR

OFFICE, DPW. PER DIRECTION FROM THE INSPECTOR IN CHARGE OR COR

SALVAGE OR SERVICEABLE MATERIALS SHALL BE RETURNED TO SUPPLY OR STORAGE

2.

3.

4.

5.

6.

7.

CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER

IF THERE ARE ANY CONFLICTS WITHIN THE CONTRACT DOCUMENT. THE GENERAL

AND DIMENSIONS PRIOR TO COMMENCING ANY CONSTRUCTION OR RENOVATION.

THE CONTRACTOR SHALL BE RESPONSIBLE IN VERIFYING ALL EXISTING CONDITION

OF THE LOAD BEARING WALLS TO PREVENT COLLAPSE OF THE STRUCTURE

APPROPRIATE TEMPORARY SUPPORTS SHALL BE CONSTRUCTED PRIOR TO DEMOLITION

9.

10.

11.

12.

13.

14.

15.

COMMENCEMENT OF FLOOR TILE WORK.

ALL CONCRETE FLOOR SURFACES SHALL BE LEVELED AND SMOOTHED PRIOR TO

WALL : 2.29 SM. DEG K/W

ROOF : 5.30 SM. DEG K/W

R-VALUE :

GENERAL NOTES

SPECIFICATION 15181.

ITEMS REQUIRING MAINTENANCE/OPERATION IAW THE SECTION 3.1.14, OMA STD

PROVIDE ACCESS DOORS FOR ALL CONCEALED VALVES, VENTS, CONTROLS AND OTHER

16.

17.

FROM THE MANUFACTURE SHOWING THE PRODUCT IS LEAD FREE.

A CERTIFICATE OR MATERIAL SAFETY DATA SHEET (MSDS), WRITTEN IN ENGLISH,

DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR SHALL PROVIDE

WITH LESS THAN 0.05 PERCENT LEAD BY WEIGHT OF THE NON-VOLATILE SOLIDS)

THE CONTRACTOR SHALL USE "LEAD FREE" COATINGS (LIQUID PAINTS OR COATINGS

ADJACENT AREAS AT HIS OWN EXPENSE.

CAUSED BY THIS PROJECT AND SHALL REPAIR THE DAMAGES TO MATCH UP TO

CONTRACTOR SHALL BE RESPONSIBLE FOR ALL DAMAGES MADE TO EXISTING AREAS

DETAILS AND GET APPROVAL FROM COR BEFORE FABRICATION AND INSTALLATION.

CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL DOOR/WINDOW

HEATING, EQUIPMENT, ETC), ELECTRICAL, TELEPHONE AND FIRE ALARM SYSTEM.

REQUIRED FOR THE INSTALLATION AND/OR REPLACEMENT OF MECHANICAL (PLUMBING,

OBSTRUCTED ITEMS, CUT, PATCH AND RESTORE WALLS, FLOORS AND CEILING WHERE

THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL/REINSTALLATION ANY

SHALL BE AS A PART OF THE CONTRACT DOCUMENT OF THIS PROJECT.

STANDARD DETAIL DRAWINGS FOR O&MA PROJECT, KOREA, DATED OCTOBER 1, 2003

DOCUMENTATION TO 8 CES/CEAN.

THE CONTRACTOR SHALL PROVIDE THE NEW SURVEY REPORT AND ASBESTOS REMOVAL

ACCORDANCE WITH THE KOREA ENVIRONMENTAL GOVERNING STANDARD (KEGS).

PRIOR TO ANY WORK TO ASSURE THAT APPROPRIATE ASBESTOS CONTROL IS IN

AREA SHALL BE RESURVEYED AND ASBESTOS MATERIALS SHALL BE REMOVED

WORK IN THE AFFECTED AREA AND NOTIFY THE CONTRACTING OFFICER. THE WORK

ASBESTOS CONTAINING MATERIAL ARE DISCOVERED, THE CONTRACTOR SHALL CEASE

IS NOT PRESENT IN THE AREAS AFFECTED BY THIS WORK: IF SUSPECTED

VERIFYING THE PRODUCT IS ASBESTOS FREE. TESTS HAVE INDICATED THAT ASBESTOS

SHALL PROVIDE A CERTIFICATE OR MSDS, WRITTEN IN ENGLISH, FROM THE MANUFACTURER

PERCENT BY WEIGHT) DURING THE EXECUTION OF THIS PROJECT. THE CONTRACTOR

THE CONTRACTOR SHALL USE "ASBESTOS FREE" MATERIALS (LESS THAN 0.1

NO. 595b, COLORS.

THE COR AND COLOR NUMBERS ARE FROM TM-5-807-7 AND FEDERAL STANDARD

COLOR OF MATERIALS & PAINTS SHALL BE SELECTED BY USING AGENCY THROUGH

W1 W1 W1 W1 W1

W2

W1 W1 W1W1W1W1W1

W2

W1 W1

W1 W1

W1 W1

L1 L2 L3

W5

D1

D8

D2

D3

D3

D11

D12

D11

D12

D11

D18

D2

D15 D15

D11 D15 D15 D15

D14 D13

D15

D13

D13

D14

R1 D2D5

D6

D5

D6

FOR TYPICAL MODULE

DOOR & WINDOW NUMBER

D4

D7

D9 D9

D17

D17 D17

D17

D19

D7

D16

D3

D10

(TYP)

MOULDING

WOODEN

2 GRANITE CURBS

REPLACE GRAVEL BED &

STOOP

REPLACE CONC

STOOP

REPLACE CONC

GRANITE CURBS

REPLACE GRAVEL BED &

SB SB

SB SB SB

STOOP

REPLACE CONC

A5

A5

A6

A6

A7

A7

1ST FLOOR PLAN AND GENERAL NOTES

AND SHUTTER

REPLACE SST SHELF

DOORS

EXST STEEL

PAINT AND REPAIR

STORAGE

ROOM

SPRINKLER

D20

COMM RM

1,400

,0

D9

INSIDE

MINIMUM

INSIDE

MINIMUM

D11

STORAGE

200THK CMU WALL

,0

REPAIR BARRACKS

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

A-2

SCALE: 1/100

2ND FLOOR PLAN

1. FLOOR WORK

2. INTERIOR & EXTERIOR WALL WORK

2.1

2.2

2.3

1.1

1.2

1.3

2.4

2.5

1.4

REPAIR / MAINTENANCE (K) WORK

SCOPE OF WORK (ARCHITECTURAL WORK)

SHOWN ON FLOOR PLANS AND SECTIONS.

COATS, WATER PROOF MEMBRANE, PLASTERING W/METAL LATH AND WATERPROOF GWB AS

REPLACE DETERIORATED EXISTING GCWT(FULL HEIGHT) WITH NEW INCLUDING CEMENT BOND

1.5

3.4

3.2

3.3

3.1

3. INTERIOR & EXTERIOR CEILING/ROOF WORK

3.5

ON FLOOR PLANS AND FINISH SCHEDULE.

WATER RESISTANT OR 'X' TYPE) CEILING INCLUDING CEILING SUSPENSION SYSTEM AS SHOWN

REPLACE DETERIORATED EXISTING CEILING WITH NEW GYPSUM WALL BOARD (GWB, NORMAL,

SECTION.

PAINT ON ALL INTERIOR CEILING SURFACES AS SHOWN ON INTERIOR FINISH SCHEDULE AND

FLOOR PLAN AND ELEVATIONS.

PAINT ALL EXISTING EXTERIOR EXPOSED METAL, WOODS, FASCIA AND SOFFIT AS SHOWN ON

FLOOR PLAN AND SECTIONS.

APPLY ACRYLIC FLUID-APPLIED WATERPROOFING COATING ON EXISTING ROOF AS SHOWN ON

MEMBRANE, MORTAR BED AS SHOWN ON FLOOR PLANS, SECTION AND DETAILS DRAWINGS.

REPLACE DETERIORATED EXISTING CMT WITH NEW INCLUDING CEMENT BOND COAT, WATERPROOF

AND INTERIOR FINISH SCHEDULE.

APPLY EPOXY COATING WITH NON SLIP GRITS ON EXISTING FLOORS AS SHOWN ON FLOOR PLAN

METAL SUSPENSION SYSTEMS AS SHOWN ON FLOOR PLANS AND INTERIOR FINISH SCHEDULE.

REPLACE DETERIORATED EXISTING CEILING WITH NEW ACOUSTICAL CEILING TILES INCLUDING

ARCHITECTURAL

90THK STL STUD WALL

LEGEND

W/ MET STUD OR APPROVED EQUAL

5/8" THK TYPE "X" GWB & 1" THK TYPE "X"GWB

UL-DESIGN U469 (GA FILE NO 7008)

1 HR FIRE RATED STUD WALL

150THK STL STUD WALL

200THK STL STUD WALL

EXST CMU WALL TO REMAIN

W/FIBER GLASS INSULATION (STC 45 MIN.)

90THK, 150THK OR 200THK STL STUD WALL

BASE IN STAIR-1 AND 2 AS SHOWN ON FLOOR PLANS AND INTERIOR FINISH SCHEDULE.

REPLACE DETERIORATED EXISTING RUBBER TILES WITH NEW INCLUDING TREAD, RISER AND STAIR

FOR NEW FLOORING. PROVIDE LEVELING CONCRETE FOR EXISTING CONCRETE SLAB IF NEEDED.

LOW SPOTS, HIGH SPOTS, PAINTING, AND UNEVEN SURFACE SHALL HAVE BEEN CORRECTED

SMOOTH, TRUE, LEVEL PLANE WITH ALL DEFECTS SUCH AS ROUGH OR SCALING CONCRETE,

FLOOR PLAN & INTERIOR FINISH SCHEDULE. THE EXISTING CONCRETE FLOORING SHALL BE

REPLACE DETERIORATED EXISTING FLOOR TILE WITH NEW PVCT INCLUDING VCB AS SHOWN ON

(STC 45) AS SHOWN ON FLOOR PLANS, SECTIONS AND DETAIL DRAWINGS.

WATER RESISTANT OR 'X' TYPE) INCLUDING METAL STUDS AND SOUND PROOF INSULAION

REPLACE DETERIORATED EXISTING ALL GWB WALL BOARD WITH NEW GWB WALL (GWB, NORMAL,

AS SHOWN ON FLOOR PLAN, DETAIL DRAWINGS INTERIOR FINISH SCHEDULE.

PAINT ALL EXISTING INTERIOR WALLS INCLUDING CMU, METAL, CONCRETE SURFACES AND STAIRWAY

DRAWINGS.

ON 1ST FLOOR FOR MECHANICAL SEWER LINE WORK AS SHOWN ON FLOOR PLAN AND MECHANICAL

REPLACE EXISTING CONCRETE SLAB AT CORRIDOR, EACH BATH ROOMS, TOILET AND LAUNDRY ROOM

SYSTEM AS PER FLOOR PLANS. SECTIONS AND DETAIL DRAWING.

CHASES / METAL COVER INCLUDING ACCESS DOOR IN EACH ROOMS FOR NEW MECHANICAL PIPING

REPLACE DETERIORAGED EXISTING PIPE CHASES / PIPE COVER WITH WATERPROOF TYPE GWB PIPE

E W

C

UPDN

UPDN

REF

STAIR-1

218A

LOUNGE

219CORRIDOR

BED ROOM

201A

BED ROOM

201B

BED ROOM

202A

BED ROOM

202B

BED ROOM

203A

BED ROOM

203B

BED ROOM

204A

BED ROOM

204B

BED ROOM

205A

BED ROOM

205B

BED ROOM

206A

BED ROOM

206B

BED ROOM

207A

BED ROOM

207B

BED ROOM

208A

BED ROOM

208B

STAIR-2

218B

LAUNDRY

BED ROOM

214A

BED ROOM

214B

BED ROOM

213A

BED ROOM

213B

BED ROOM

212A

BED ROOM

212B

BED ROOM

211A

BED ROOM

211B

BED ROOM

210A

BED ROOM

210B

BED ROOM

209A

BED ROOM

209B

JAN

S/S

D

D

W

W

SS

61,169

7,7297,6207,6207,6207,6207,6207,6207,721

,0

,8

,6

,9

,9

,6

,9

,4

2,4407,6487,6487,6487,6487,6487,6485,5833,2532,538535

FEC OPENING

BLOCK-UP

FEC OPENING

BLOCK-UPW4

W2

W1 W1

W3

W1 W1

W2

D5 D5

D6D6

FOR TYPICAL MODULE

DOOR & WINDOW NUMBER

D3

D3 D4

D7

D9

D17 D17

D17 D17

D19

THE BUILDING AS SHOWN ON FLOOR PLAN AND DETAIL DRAWINGS.

STAIRWELS AND OTHER COMPONENTS (BICYCLE RACK, TRASH BIN, ETC.) OF EXTERIOR SURFACE OF

PAINT ALL EXISTING EXTERIOR WALLS INCLUDING EIFS, CMU, METAL, WOODS, CONCRETE SURFACES, 2ND FLOOR PLAN AND SCOPE OF WORK

2.6

FINISH SCHEDULE. NEW CMU WALL SHALL BE BUILT TO THE END OF THE CONC CEILING.

PROVIDE 200THK CMU WALLS FOR NEW RM.123 & RM.125 AS SHOWN ON FLOOR PLAN AND

A-3

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/100

3RD FLOOR PLAN

4.6

4.7

4.8

4.9

4.10

4.11

4.1

4.3

4.4

4.5

4.2

REPLACE DETERIORATED EXISTING WINDOW HORIZONTAL MINI BLINDS WITH NEW, FIREPROOF TYPE.

SETS AS SHOWN ON NEW FLOOR PLAN AND DOOR SCHEDULE.

REPLACE DETERIORATED EXISTING DOORS AND DOOR FRAMES WITH NEW INCLUDING HARDWARE

AND WINDOW SCHEDULE.

THERMAL BREAKER TYPE WINDOWS INCLUDING GLASS AS SHOWN ON FLOOR PLANS, ELEVATIONS

REPLACE DETERIORATED EXISTING WINDOWS INCLUDING INSECT SCREEN WITH NEW ALUMINUM

4. MISC. WORK

REPAIR / MAINTENANCE (K) WORK

SCOPE OF WORK (ARCHITECTURAL WORK)

90THK STL STUD WALL

LEGEND

W/ MET STUD OR APPROVED EQUAL

5/8" THK TYPE "X" GWB & 1" THK TYPE "X"GWB

UL-DESIGN U469 (GA FILE NO 7008)

1 HR FIRE RATED STUD WALL

150THK STL STUD WALL

200THK STL STUD WALL

EXST CMU WALL TO REMAIN

W/FIBER GLASS INSULATION (STC 45 MIN.)

90THK, 150THK OR 200THK STL STUD WALL

AS SHOWN ON FLOOR PLANS AND DETAIL DRAWING.

REPLACE DETERIORATED EXISTING METAL SHELF WITH MOP RACK WITH NEW IN JANITOR ROOM

LOUVER SCHEDULE.

REPLACE DETERIORATED EXISTING ALUMINUM LOUVER WITH NEW AS SHOWN ON FLOOR PLANS AND

AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING ALL TOILET ACCESSORIES WITH NEW AS SHOWN ON FLOOR PLANS

ON FLOOR PLAN AND ENLARGED FLOOR PLAN.

REPLACE DETERIORATED EXISTING ALL ACCESS DOORS ON WALL & CEILING WITH NEW AS SHOWN

CABINET AS SHOWN ON FLOOR PLAN, ELEVATION AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING KITCHENETTE WITH NEW INCLUDING BASE CABINET AND UPPER

ELEVATIONS AND SIGNAGE SCHEDULE.

REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON FLOOR PLAN, 4.13

4.14

4.15

4.16

4.17

E W

C

UPDN

UPDN

STAIR-1

318A

PURPOSE RM

319CORRIDOR

BED ROOM

301A

BED ROOM

301B

BED ROOM

302A

BED ROOM

302B

BED ROOM

303A

BED ROOM

303B

BED ROOM

304A

BED ROOM

304B

BED ROOM

305A

BED ROOM

305B

BED ROOM

306A

BED ROOM

306B

BED ROOM

307A

BED ROOM

307B

BED ROOM

308A

BED ROOM

308B

BED ROOM

314A

BED ROOM

314B

BED ROOM

313A

BED ROOM

313B

BED ROOM

312A

BED ROOM

312B

BED ROOM

311A

BED ROOM

311B

BED ROOM

310A

BED ROOM

310B

BED ROOM

309A

BED ROOM

309B

STAIR-2

MULTI

LAUNDRY

JAN

S/S

D

D

W

W

SS

7,7297,6207,6207,6207,6207,6207,6207,721

61,169

,0

,8

,6

,9

,9

,6

,9

,4

2,4407,6487,6487,6487,6487,6487,6485,5833,2532,538535

FEC OPENING

BLOCK-UP

FEC OPENING

BLOCK-UPW4

W2

W1 W1

W3

W2

W1 W1

D5 D5

D6 D6

FOR TYPICAL MODULE

DOOR & WINDOW NUMBER

D3

D4

D9

D17 D17

D17 D17

D19

D3 D7

AS SHOWN ON FLOOR PLANS AND DETAIL DRAWING.

REPLACE DETERIORATED EXISTING FIRE EXTINGUISHERS CABINETS(FEC) WITH NEW AT RM.114

REPAIR AND BLOCK UP DAMAGED EXISTING EIFS WITH NEW AS NECESSARIES.

ON FLOOR PLANS AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING VANITY CABINETS WITH NEW IN EACH TOILET AS SHOWN

CLOSET AS SHOWN ON FLOOR PLANS AND DETAIL DRAWINGS.

REPLACE DETERIORATED EXISTING WOODEN SHELVES AND RODS WITH NEW IN EACH WALK-IN

FLOOR PLAN, ELEVATIONS AND SIGNAGE SCHEDULE.

REPLACE INTERIOR & EXTERIOR SIGNAGES WITH NEW FOR ALL ROOMS AS SHOWN ON

WITH NEW AS SHOWN ON FLOOR PLANS, DETAIL DRAWING AND SIGNAGE SCHEDULE.

REPLACE DETERIORATED EXISTING EXT/INT BULLETIN BOARDS, CARD HOLDER AND FLEXI INFO 4.18

MATCHING TO EXISTING WALL SURFACES AS SHOWN ON FLOOR PLANS.

REMOVE AND BLOCK-UP EXISTING FIRE EXTINGUISHER CABINETS(FEC) OPENINGS AND PATCH UP 4.19

3RD FLOOR PLAN AND SCOPE OF WORK

FLOOR PLAN.

REPLACE DETERIORATED EXISTING CONCRETE STOOPS WITH NEW AS SHOWN ON

ON DOOR/WINDOW SCHEDULE. (NATURAL COLOR, OAK)

REPLACE DETERIORATED EXISTING WOODEN HEAD, JAMB & SILL FOR ALL WINDOWS WITH NEW AS SHOWN

LAUNDRY ROOM AS SHOWN ON FLOOR PLAN AND DETAIL.

REPLACE DETERIORATED EXISTING LAUNDRY TABLE AND SHELF WITH NEW IN EACH

4.12

FLOOR PLANS, ELEVATIONS AND DETAILS DRAWINGS.

NEW IN EACH BED ROOM, LOUNGE AND MULTI-PURPOSE ROOMS AS SHOWN ON

REPLACE EXISTING DETERIORATED WOODEN CHAIR RAILS AND HANGING RAILS WITH

DETAIL DRAWING.

GRAVEL BED INCLUDING GRANITE CURB AROUND BUILDING AS SHOWN ON FLOOR PLAN AND

REPLACE DETERIORATED EXISTING GRAVEL BED AND CONC CURB WITH NEW 100mm DEEP

4.20

4.22

4.21

SURFACES AND PATCH WITH EIFS MATCHING TO EXISTING WALL SURFACES.

BLOCK-UP ALL EXISTING FRESH AIR INTAKE LOUVER OPENINGS ON THE EXTERIOR WALL

A-4

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/100

4TH FLOOR PLAN

90THK STL STUD WALL

LEGEND

W/ MET STUD OR APPROVED EQUAL

5/8" THK TYPE "X" GWB & 1" THK TYPE "X"GWB

UL-DESIGN U469 (GA FILE NO 7008)

1 HR FIRE RATED STUD WALL

150THK STL STUD WALL

200THK STL STUD WALL

EXST CMU WALL TO REMAIN

W/FIBER GLASS INSULATION (STC 45 MIN.)

90THK, 150THK OR 200THK STL STUD WALL

E W

C

DN

DN

STAIR-1

418A

PURPOSE RM

419CORRIDOR

BED ROOM

401A

BED ROOM

401B

BED ROOM

402A

BED ROOM

402B

BED ROOM

403A

BED ROOM

403B

BED ROOM

404A

BED ROOM

404B

BED ROOM

405A

BED ROOM

405B

BED ROOM

406A

BED ROOM

406B

BED ROOM

407A

BED ROOM

407B

BED ROOM

408A

BED ROOM

408B

BED ROOM

414A

BED ROOM

414B

BED ROOM

413A

BED ROOM

413B

BED ROOM

412A

BED ROOM

412B

BED ROOM

411A

BED ROOM

411B

BED ROOM

410A

BED ROOM

410B

BED ROOM

409A

BED ROOM

409B

STAIR-2

418B

MULTI

LAUNDRY

JAN

S/S

D

D

W

W

SS

7,7297,6207,6207,6207,6207,6207,6207,721

61,169

,0

,8

,6

,9

,9

,6

,9

,4

2,4407,6487,6487,6487,6487,6487,6485,5833,2532,538535

FEC OPENING

BLOCK-UP

FEC OPENING

BLOCK-UP W4

W2

W4

W2

W1 W1 W1 W1

D5 D5

D6 D6

FOR TYPICAL MODULE

DOOR & WINDOW NUMBER

D3

D4

D7

D9

D17 D17

D17 D17

D19 D3

4TH FLOOR PLANS AND PICTURES

PAINT STORAGE BIN & OIL TANK

REPLACE RAINGUTTER & CONC STOOP

A-5

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/100

ELEVATION-1

SCALE: 1/100

ELEVATION-2

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

AL BLAST WINDOW(TYP)

APPLY ACRYLIC FLUID-APPLIED WATERPROOFING

ON EXISTING PROTECTED METAL ROOF

EXST MET CANOPY

PAINT ON

EXST MET CANOPY

PAINT ON

CONC STOOP CONC STOOP CONC STOOP

PAINT (TYP)

APPLY ACRYLIC FLUID-APPLIED WATERPROOFING

ON EXISTING PROTECTED METAL ROOF

PATCH WALL & FLOOR SURFACES

REMOVE CONC FLOWER BOX AND CONC STOOP

AL BLAST WINDOW(TYP)

REPLACE BULLETIN BOARD

ELEVATIONS AND PICTURES

PATCH WITH EIFS MATCHING TO EXISTING WALL SURFACES.

OPENINGS ON THE EXTERIOR WALL SURFACES AND

* BLOCK-UP ALL EXISTING FRESH AIR INTAKE LOUVER

EXST FAIL OPENINGS

BLOCK-UP ALL

PAINT 2(TWO) EA BIKE RACKS AND SHEDS

A-6

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/100

ELEVATION-1

SCALE: 1/100

ELEVATION-2

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

GRANITE CURB

REPLACE GRAVEL BED &

REPLACE COUTER DESK, SEE A-13/2

REPLACE LAUNDRY TABLE & SHELVE

WALL LININGS(W/GCWT)

REPLACE KITCHENETTE SYSTEM &

APPLY ACRYLIC FLUID-APPLIED WATERPROOFING

ON EXISTING PROTECTED METAL ROOF EXST CHIMNEY

PAINT ON

(TYP)

AL BLAST WINDOW

PAINT ON EXST EIFS REPLACE EXST AL LOUVERS

EXST CHIMNEY

PAINT ONAPPLY ACRYLIC FLUID-APPLIED WATERPROOFING

ON EXISTING PROTECTED METAL ROOF

(TYP)

AL BLAST WINDOW

PAINT ON EXST EIFS

CONC STOOP

ELEVATIONS AND PICTURES

PATCH WITH EIFS MATCHING TO EXISTING WALL SURFACES.

OPENINGS ON THE EXTERIOR WALL SURFACES AND

* BLOCK-UP ALL EXISTING FRESH AIR INTAKE LOUVER

EXST FAIL OPENINGS

BLOCK-UP ALL

PROVIDE GWB WALL LININGS

A-7

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE: 1/100

GENERAL SECTION-1

SCALE: 1/100

GENERAL SECTION-2

BED ROOM MULTI-PURPOSE

BED ROOM BED ROOM

BED ROOM BED ROOM

BED ROOMBED ROOM

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

MECH ROOM

STORAGE MULTI-PURPOSE ROOM COMMO SHOP NBC ROOM SUPPLY ROOM COMM XO CO

BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM

BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM

BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM BED ROOM

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

CONC PAD & SLAB

DET.

12THK GWB ON 203

METAL STUD @ 400 O.C

W/INSUL & V.R

,4

,4

,2

,2

,5

,4

,2

,2

V A

R

V A

R

,4

,4

,4

,0

,4

,4

,4

,4

,4

1102020

GRAVEL

BED.

SCALE:

CONC CURB & GRAVEL BED DETAIL

1 : 10

GRANITE CURB

EXST EIFS AND CMU

PAINT ON

GENERAL SECTIONS AND DETAILS

A-8

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE:

1/30

EXT/INTR WALL SECTION

1B

1A

KEY PLAN

TOP OF BEAM

3RD FL

2ND FL

1ST FL

4TH FL

BED ROOM

BED ROOM

BED ROOM

BED ROOM

PAINT ON

GWB CLG

PAINT ON

GWB CLG

PAINT ON

GWB CLG

PAINT ON

EXIST CMU WALL

REPLACE EXIST

REPLACE EXIST

VCB W/ NEW

PAINT ON

EXIST CMU WALL

REPLACE EXIST

REPLACE EXIST

VCB W/ NEW

PAINT ON

EXIST CMU WALL

REPLACE EXIST

REPLACE EXIST

VCB W/ NEW

PAINT ON

EXIST CMU WALL

REPLACE EXIST

REPLACE EXIST

VCB W/ NEW

1A1B

BED ROOM BED ROOMBATH ROOM

BED ROOM BED ROOMBATH ROOM

PAINT ON

WATER RESISTANT

GWB CLG

GCWT ON

THINSET MORTAR

ON CEMENT MORTAR

BASE ON MET LATH

ON 15 LB ASPHALT FELT

CMT ON

MORTAR BED

BITUMINOUS

WATER PROOFING

@ 2ND, 3RD, 4TH FL ONLY

REPLACE EXIST

REPLACE EXIST

VCB W/ NEW (TYP)

PAINT ON

EXIST CMU WALL (TYP)

PAINT ON 12THK

GWB CLG (TYP)

PROVIDE NEW

MINI-BLIND(TYP)

1ST FL

2ND FL

1ST FL

STORAGE

PAINT ON

2ND FL

CMU WALL

PAINT EXIST

REPLACE EXIST

VCB W/ NEW

REPLACE EXIST

C L

G

H

G T

BEDROOM

BEDROOMBEDROOM

1C

CMU WALL

PAINT EXIST

1C

REPLACE

EXIST WINDOW

W/ NEW

REPLACE

EXIST WINDOW

W/ NEW

REPLACE

EXIST WINDOW

W/ NEW

REPLACE

EXIST WINDOW

W/ NEW

PAINT

EXIST EIFS

(TYP)

PAINT ON

GWB CLG

CMT ON MORTAR BED

ON BITUMINOUS WATER

PROOFING ON EXIST

CONC SLAB

@2ND, 3RD 4TH FL ONLY

ON NEW CONC SLAB

(TYP)

12THK GWB CLG (TYP)

PAINT EXIST

CONC SLAB

REPLACE EXIST

GCWT ON THINSET

MORTAR ON CEMENT

MORTAR BASE ON MET LATH

ON 15 LB ASPHALT FELT ON

REPLACE EXIST

VCB W/ NEW

REPLACE EXIST

VCB W/ NEW

REPLACE EXIST

REPLACE EXIST

REPLACE EXIST

VCB W/ NEW

@ 1ST FL ONLY

,5

,4

,2

,2

,6

,4

,4

,4

,0

,4

,2

,4

,4

,2

C L

G

H

G T

C L

G

H

G T

C L

G

H

G T

C L

G

H

G T

C L

G

H

G T

C L

G

H

G T

REPLACE WOODEN

SILL W/ NEW (TYP)

CMU WALL (TYP)

ON CMU WALL

RAIL

HANGING

WOODEN

REPLACE WOODEN

SILL W/ NEW (TYP)

SHOWER AREA

SCALE:

1 : 20

SHOWER CURB DETAIL

BATH ROOM

R=5

12 THK SSM

SEALANT

WATER PROOFING

MEMBRANE

SHOWER AREA

SHOWER CURTAIN

SLOPE SLOPE

CERAMIC FLOOR

TILE

CEMENT MORTAR

BED

SHOWER CURTAIN

W/ROD

FABRIC REINF

WATER PROOFING

MEMBRANE

EXST CONC OR BRICK CURB

AND DETAILS

EXT/INTERIOR WALL SECTIONS

PVCT W/ NEW

PVCT W/ NEW

PVCT W/ NEW

PVCT W/ NEW

PVCT W/ NEW (TYP)

PVCT W/ NEW

PVCT W/ NEW PVCT W/ NEW

PVCT W/ NEW

A-9

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

PIPE CHASE FOR

FCU MECH WORK

(TYP)

SCALE: 1/50

BED ROOM BED ROOM

CLOSET CLOSET

DRESSING

BATH ROOM

DRESSING

TB

SH

LAV LAV

TTD

WCTB

7,620

,9

,6

,6

,8

,0

3,6841523,659

SCALE:

1/30

JAN

WC

WC

TTD

TTD

UR

LAV

LAV

EWC

LAV

WC

TTD

FD

FD

MEN

WOMEN

UB

PTD

PTD

SS

DAY RM INTERIOR ELEVATIONS

1/50

SCALE:

DRESSING INTERIOR ELEVATIONS

1/50

SCALE:

,4

,6

2031,6515083,302102

5,563

1,626

,7

,6

MG

A

M G

FIXTURE

LIGHTING

GCWT

REF(GFGI)

VERIFY SPACE FOR

C L

G

H

G T M/W

FOR RANGE

VERIFY SPACE

(GFGI)

EQEQEQEQEQ

1E

A10 A10

1B 1C

A10

1D

A10

A10

1A

W/SST SHELF

MOP RACK

SC W/ROD

MC

MC

NEW TYPICAL 1ST, 2ND, 3RD & 4TH FLOOR MODULE PLAN

TOILET PARTIAL PLAN ON 1ST FL

A10

1E

PIPE CHASE (TYP)

PIPE CHASE (TYP)

TP

MC

GWB WALL

PAINT ON NEW

CHAIR RAIL

(TYP)

HANGING RAIL

ELEVATIONS

TYPICAL & PARTIAL PLANS AND

50 775 2030 945

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

A-10

13 THK SOLID SURFACING

MATERIAL (SSM-1) ON 18 THK

GCWT W/ BOND COAT

SEALANT

20x100

WD SHIM

WD SHIM

20x100

C L

G

H

T

20X100 WD

(SEE ELEC DWG)

LIGHTING

MIRROR ON 7.5 THK PLYWD

MARINE EDGE

ON 18 THK PLYWOOD

10 DIA POLISHED BRASS ROD

PULL @ EACH DOOR (B02011)

W/ HINGE (2PR-BO1602

@ EACH DOOR)

ON 18 THK PLYWOOD

(TOP & EDGE)

(FRONT, BACK & EDGE)

50X100 WOOD

PLASTIC LAMINATE (PL-1)

ON 18 THK PLYWOOD (FRONT)-TYP

FULL @ EACH DOOR

(B02011) 10 DIA POLISHED BRASS ROD

PLASTIC LAMINATE (PL-1)

(TOP,BOTTOM, & EDGE)-TYP

ON 18 THK PLYWOOD

CEILING LINE

,8

PLASTIC LAMINATE (PL-2)

PLASTIC LAMINATE (PL-2)

PLASTIC LAMINATE (PL-2)

PLASTIC LAMINATE (PL-1)

ON 7.5 THK PLYWOOD

ON 7.5 THK PLYWOOD

SEALANT

20x100

WD SHIM

WD SHIM

20x100

CEILING LINE

,8

0 C

T

(TYP)

20x100

TREATED

WD SHIMC

T

T O

F

REF (GFGI)

PLYWOOD

SIDE SPLASH)

MARINE EDGE

ON 18 THK

(2PR-B05011

@ EACH DOOR)

VCB

PLYWOOD (TOP & EDGE)

(COUNTERTOP, BACK &

13 THK SOLID SURFACE

ON 18 THK PLYWOOD

METAL PULL (B02011)

DRAWER W/ SLIDE

PLASTIC LAMINATE (PL-1)

(TYP)

(TYP)

C

T

(TYP)

UPPER CABINET DETAIL

50x100

TREATED WD

FRAME

PLASTIC LAMINATED (PL-1) ON

18 THK PLYWOOD (FRONT)

MICROWAVE(GFGI)

(VERIFY SIZE)

PLASTIC LAMINATED (PL-1)

ON 18 THK PLYWOOD

(TOP, EDGE & BOTTOM)

20x100

TREATED

WD SHIM

GCWT ON CEMENT MORTAR

ON 12 THK CEMENT BOARD

ON METAL STUD @ 400 OC (MAX)

PLASTIC LAMINATED (PL-2)

INTERIOR 18 THK PLYWOOD

(TOP & EDGE)

PLASTIC LAMINATED (PL-2)

INTERIOR ON 7.5 THK PLYWOOD

(FRONT)

PLASTIC LAMINATED (PL-1) ON 18

THK PLYWOOD (FRONT & EDGE)

W/ HINGE (2PR-BO1602)

W/ (@ EACH DOOR)

PULL @ EACH DOOR (B02011)

10 DIA POLISHED BRASS ROD

MARINE EDGE

13 THK SOLID SURFACE (SSM-1)

MATERIAL OVER 18 THK PLYWOOD

(COUNTERTOP, BACK & SIDE

SPLASH GUARD)

METAL

ADJUSTABLE

PLASTIC LAMINATED

INTERIOR

ON 18 THK PLYWOOD

(TOP,BOTTOM & EDGE)

25X50 WD

SEALANT

50x100

TREATED WD

FRAME

PLASTIC LAMINATED

(PL-1)

ON 18 THK

PLYWOOD (FRONT)

50x100 TREATED WD FRAME

PLASTIC LAMINATED (PL-1)

ON 18 THK PLYWOOD (FRONT)

PLASTIC LAMINATED (PL-1)

N 18 THK PLYWD (FRONT & EDGE

W/ HINGES 2PR - B01602 @ EACH DOOR)

PLASTIC LAMINATED (PL-2)

INTERIOR ON 18 THK PLYWD (BOTTOM & EDGE)

PLASTIC LAMINATED (PL-2)

INTERIOR ON 18 THK PLYWOOD

(TOP,BOTTOM & EDGE)

PLASTIC LAMINATED (PL-2)

INTERIOR ON 7.5 THK PLYWOOD (FRONT)

MET ADJ SHELF HARDWARES

(B04071 & B04081)

PULL @ EACH DOOR (B02011)

10 DIA POLISHED BRASS ROD

PLASTIC LAMINATED (PL-1)

ON 18 THK PLYWOOD

(BOTTOM)

20x100

TREATED

WD SHIM

GCWT ON CEMENT MORTAR

ON 12 THK CEMENT BOARD

ON METAL STUD @ 400 OC (MAX)

13 THK SOLID SURFACE (SSM-1)

MATERIAL OVER 18 THK

PLYWOOD (COUNTERTOP, BACK &

SIDE SPLASH GUARD)

MARINE EDGE

KITCHEN SINK (UNDER HUNG TYPE)

(SEE MECH DWG)

PLASTIC LAMINATED (PL-2)

INTERIOR 18 THK PLYWOOD

(TOP & EDGE)

PLASTIC LAMINATED (PL-2)

INTERIOR ON 7.5 THK PLYWOOD(FRONT)

PLASTIC LAMINATED (PL-1)

ON 18 THK PLYWOOD (FRONT & EDGE)

W/ HINGE (2PR-BO1602 @ EACH DOOR)

PULL @ EACH DOOR (B02011)

10 DIA POLISHED BRASS ROD

SEALANT

25X50 WD

PLASTIC LAMINATED (PL-2)

INTERIOR ON 18 THK PLYWOOD

(TOP,BOTTOM & EDGE)

PLASTIC LAMINATE (PL-2)

MATERIAL (SSM-1) OVER 18 THK

1B 1C

1D 1E

PULL @ EACH DOOR (B02011)

10 DIA POLISHED BRASS ROD

(PL-1).

PLYWD PANEL W/ PLASTIC LAMINATE

CONSTRUCTED OF SOLID WD TRIMS &

END PANEL AND ETC. SHALL BE

INCLUDING DOOR, DRAWER FRONTS, SIDE

ALL EXPOSED COUNTER CABINET FACES

5.

6.

(PL-2).

FINISHED W/ PLASTIC LAMINATE

ALL CABINET INSIDE SURFACE SHALL BE

7.

FOR THE SOUND SILENCE.

EQUIPPED WITH RUBBER BUMPER

ALL CABINET DOORS SHALL BE

AND TO BE INSTALLED BY OTHER.

GOVERNMENT FURNISHED MATERIALS

MICROWAVE, RANGE AND REFRIGERATOR WILL BE 1.

2.

3.

4.

FINISHED W/ SOLID SURFACE MATERIAL (SSM-1).

ALL CABINET COUNTERTOP SHALL BE

8.

SOLID SURFACE MATERIALS FOR APPROVAL.

OF HARDWARE, PLYWOOD, PLASTIC LAMINATE &

AND TEST REPORTS, CERTIFICATIONS

OF KITCHEN CABINETS WITH HARDWARE,

CONTRACTOR SHOULD SUBMIT SHOP DRAWING

TWO (2) INCHES ACTURAL SIZE OF THE REF.)

JOB SITE, (REFRIGERATOR SPACE SHALL BE

AND CABINET SIZE WILL BE ADJUSTED ON THE

REFRIGERATOR DIMENSION IS APPROXIMATE

SELECTED BY USING AGENCY.

PLASTIC LAMINATED COLOR TO BE

PLYWOOD (COUNTER TOP, SIDE & BACK )

SCALE : 1/10

CABINET DETAILS

1A

CABINET NOTE

CABINET DETAILS AND NOTES

VANITY CABINET DETAIL KITCHEN CABINET DETAIL KITCHEN CABINET DETAIL

LOWER DRAWER CABINET DETAIL

SSM-1

OR APPROVED EQUAL

MELATON, 1157EA

PLASTIC LAMINATED SHEET

OR APPROVED EQUAL

MELATON, 3357EA

PLASTIC LAMINATED SHEET

PL-1

PL-2

OR APPROVED EQUAL

CRYSTAL PACIFIC, #NP932

SAMSUNG STARON MFG,

SOLID SURFACE MATERIAL

A-11

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

T O

F

L O

O R

WD FRAME

CLOTHES HANGING ROD W/

25x32 WD. NAILER W/

18 THK. PLYWD SHELF

WOOD DOOR

(SEE DOOR SCUEDULE)

VCB

PVCT

1H

FINISH(POST FRAMING COUNTER TOP)

ANCHOR BOLT

@ 450 O.C

25X50 WD.

SPACER

WOOD DOOR

C E

IL

IN

G

H

G T

SEALANT

#2 OR #4

DOOR FRAME

VARNISH ON

1B

1C

SEALANT #2 OR #4

(BELOW TOP)

FILLER PANEL

WOOD DOOR

MATERIAL

BACK STOP

O R

CABINET

TOP OF

CABINET WALL

1D

1E

1J

O R

HD.WD.TRIM

12 THK. GWB

CEILING

WD. DOOR

WD. DOOR FRAME

WD. FRAME

CEILING

12 THK. GWB

SHELF CLOTHES

HANGING ROD

PROVIDE A FACE PANEL AT EACH END

THE CLOSET DOORS ARE OPEN

DRAWER WIDTH SHALL BE 500 mm.

DRAWERS TO OPEN FULLY WHEN

OF DRAWER UNIT TO ALLOW THE

X NOTE ;

PLYWOOD W/PLASTIC LAM(PL-1)

EXST CMU

PAINT ON

20x40 WD. TRIM

VARNISH ON EXST

GWB WALLS

PAINT ON EXST

WD. DOOR FRAME

VARNISH ON EXST

WD. DOOR FRAME

VARNISH ON EXST

HD. WD. TRIM

VARNISH ON EXST

EXST CMU

PAINT ON

PLASTIC LAMINATE(PL-1) ON

PAINT ON CMU

VARNISH ON EXST

EXST TRIM

VARNISH ON EXST

VARNISH ON EXST

VARNISH ON EXST

EXST CMU

PAINT ON

VARNISH ON EXST

20x50 WD TRIM

VARNISH ON EXST

TC ON

TC ON

CABINET

DRAWER

CLOSET DETAILS

SCALE:

AS SHOWN

CLOSET DETAILS

A-15

SCALE:

1J

SECTION

SCALE:

1A

CLOSET PLAN

1 : 30

1 : 5

SCALE:

1B

PLAN DETAIL

1 : 5 SCALE:

1C

HEAD DETAIL

1 : 5

SCALE:

1D

1 : 30

ELEVATION

SCALE:

1E

SECTION DETAIL

SCALE:

1F

JAMB DETAIL

SCALE:

1G

1 : 5

PLAN DETAIL

1 : 5 1 : 5

1G

VARNISH ON EXST

20x50 WD TRIM

20x50 WD TRIM

VARNISH ON EXST

116509

50 EQ EQ195 50

15010001000

,8

,2

,4

PAINT ON WALL

A12

SST PLATE

CLOTHES

POSTFORM

HANGING ROD

BRACKET

25 DIA SST PIPE

PLASTIC LAMINATE

ON 18 THK PLYWOOD

W/ 9 DIA EXP BOLT

BOTH SIDES-SHELF

PLASTIC LAMINATE

& SIDE PANEL

ON 18 THK PLYWOOD

6 THK. PLYWD W/

DRAWER STOPPER

20x40 HARD WD. 18 THK. PLYWD. W/

CABINET DRAWER

T

Y P

HARDWD TRIM

20x20

PLASTIC LAM(PL-1)

PLASTIC LAMINATE(PL-2)

SCALE: 1 : 5

1H

DETAIL-5

A-12

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

PLASTIC LAMINATE (PL-1)

HANGING ROD

4 DIA HOLE (TYP)

CLOTHES

25 DIA SST PIPE

-25x25x2

2.5 THK SST

BRACKET

O O

R

HANGING ROD

SST BRACKET

CLOTHES

2.5 THK

25 DIA SST PIPE

-25x25x2 SST BRACKET

POSTFORM

9 DIA TOGGLE BOLTS

22x200 WOOD

1.6 THK SST SOCKET

CLOTHES HANGING ROD

25 DIA SST PIPE

R

5 50

0 50

9 DIA TOGGLE BOLTS

PAINT GWB

PAINT CMU

BOTH SIDES-SHELF & SIDE PANEL

ON 18 THK PLYWD

PLASTIC LAMINATE (PL-1)

ON 18 THK PLYWD

@ 300 O.C

SEE DETAIL

1C

@ 900 OC

@ 900 OC

SCALE: 1/5

SHELF & ROD DETAILS (CLOSET)

100350

1A 1B

1C

@ 900 OC

SCALE:

1/10

3/4 HR FIRE RATED SHUTTER DETAILS

C L E

A R

O

P N

G

H G

T

2B S I L L 2C J A M B

SHUTTER

M.O

HGT

SHUTTER

JAMB FRAME

#16 GA. METAL

ANCHOR PLATE

FRAME

METAL SILL

#14 GA.C

L E

A R

O

P N

G

H G

T

2A H E A D

HOOD

FRAME

METAL HEAD

#16 GA.

FASCIA

SHUTTER

50 THK

3 THK CLOSED

GUSSET GAL.

TOP WOOD BOARD

50 DIA

TUBING GAL.

L-50x50x3t

GAL. (TYP)

25 DIA TUBING

GAL. @ 100 O.C

(TYP)

ADJUSTABLE FEET

W/ 60 DIA STL.

ANCHOR BOLTS.

(TYP)

LINE

FLOOR FINISH

(TYP)

SECTION

50 THK

TOP WOOD BOARD

3 THK CLOSED

GUSSET GAL.

(TYP)

L-50x50x3t

GAL. (TYP)

50 DIA

TUBING GAL.

(TYP)

25 DIA TUBING

GAL. (TYP)

ADJUSTABLE FEET

W/ 60 DIA STL.

ANCHOR BOLTS.

(TYP)LINE

FLOOR FINISH

ELEVATION

EQ EQ EQ EQ

30 DIA STAINLESS

STL PIPE CLOTHES

HANGING ROD W/

5THK x 50W

SST PLATE

PLASTIC LAMINATE ON

18THK PLYWOOD, TOP,

& BOTTOM

SHELVE

DETAIL

3C

A12

A

A

& BOTTOM

18 THK PLYWOOD, TOP,

PLASTIC LAMINATE ON

5 THK x 50W

SST PLATE WELDED

W/ 9DIA EXP BOLTS

OR TOGGLE BOLTS

TOGGLE BOLTS

2-6 DIA

3A 3B

SCALE:

1/10

LAUNDRY TABLE AND SHELVE DETAILS

3C

30 DIA STAINLESS

STL PIPE CLOTHES

HANGING ROD W/

SHELVE DETAIL

75 600 75

36080 80

730 730 730

100 100

100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100

MISC. DETAILS-1

PLASTIC LAMINATED

40x40 OAK

NOSING W/ 12RADIUS

MET. PULL (B02011)

PLASTIC LAMINATE

ON 20THK PLYWOOD

DRAWER FRONTS

FULLY EXTENDIBLE METAL

DRAWER SLIDES

(1PR-B05011 @EACH DRAWER)

PLASTIC LAMINATE

6THK PLYWOOD

DRAWER BOTTOMS

PLASTIC LAMINATE

ON 20THK PLYWOOD

20x20 OAK

NOSING W/ 12RADIUS

PLASTIC LAMINATE

ON 20THK PLYWOOD

VCB

PVCT

50x100

TREATED WOOD

30x100 OAK

NOSING W/ 12RADIUS

PVCT

PAINT

EXIST CMU WALL

SCALE : 1/10

COUNTER DETAILS AT OFFICE

VCB

,0

20030 370

A-13

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

SCALE : 1/5

FILLER SECTION DETAIL

EXIST SLAB

CMU WALL

EXIST

4.6

.5

1.2 THK STEEL

SHT COVER

(COLOR TO

MATCH FCU)

L-50x50x6

2EA-

STL FRAME

50x50x6 PLATE

WELD TO FRAME

W/12 DIA EXP BOLT

@ EACH FRAME

VCB

L-50x50x6

STL FRAME

@ 400 OC

@ 400 OC (TYP)

PAINT 15 THK GWB

ON 92 MET STUD

ACCESS DOOR

AT 1ST FLOOR ONLY

200W x 200H LOCKET

SCALE : 1/10

PIPE CHASE PLAN DETAIL

PAINT

EXISTING WALL

(OUTSIDE TRIM DIM.)

(OUTSIDE TRIM DIM.)

(INSIDE BOX DIM.)

FIRE EXTINGUISHER CABINET PLAN

L

IN

S

ID

E

B

X

D

IM

O

U T S

R

METAL DOOR

PULL

METAL TRIM

METAL FIRE

EXTINGUISHER CABINET

METAL DOOR PULL

GLASS

(INSIDE BOX DIM.)

WOOD SHIM

(ALL AROUND)

CONC.FILL

IN

S

B

X

FLOOR FINISH

VCB

LINE

PULL

METAL DOOR

WOOD SHIM

(ALL AROUND)

SIDE)

SCREW (3-PER

A

A

1 : 10

1B

1A

1C

PAINT

ON EXST CMU

SCALE:

FIRE EXTINGUISHER CABINET

ELEVATION SECTION "A-A"

4430544

114 89

EXST CMU WALL

ON 2P-20THK PLYWOOD

MISC. DETAILS-2

A-14

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

ABBREVIATION

ROOM NAMESROOM NOS

INTERIOR FINISH SCHEDULE

FLOOR BASE WALLS CEILING

REMARKS

FINISH COLOR FINISH COLOR FINISH COLOR FINISH COLOR HEIGHT

SURFACE

ROOFING

FLASHING

FASCIA

SOFFIT

DOOR & FRAME

HANDRAIL

MATERIAL

ROOF LINER

STEEL

STEEL PIPE

COLOR

CHOCOLATE

COLOR NO.

20095

CHOCOLATE

CHOCOLATE

CHOCOLATE

CHOCOLATE

CHOCOLATE

20095

20095

20095

20095

20095

REMARKS

WALL EIFS

WALL CMU

BEAM/COL CONC

STAIR CONC

SAND-STONE

SAND-STONE

SAND-STONE

SAND-STONE

23617

23617

23617

23617

PROTECTED METAL

PROTECTED METAL

PROTECTED METAL

EXTERIOR COLOR SCHEDULE-1

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FS 595B

FIRE EXTINGUISHER CABINETFEC

GYPSUM WALL BOARD

SOUND ABSORPTION WALL PANEL

QT QUARRY TILE

VINYL COVE BASEVCB

SAWP

FACTORY FINISH

HARDENER

PROTECTED METALPM

GWB

HDR

FF

EXTERIOR INSULATION & FINISH SYSTEM

CHAIN-LINK PARTITIONCP

EIFS

ACOUSTICAL TILEACST

CMU CONCRETE MASONRY UNIT

PVCT

ATT ASPHALT TIRE TILE

MATERIAL & COLOR SCHEDULE

FLOOR MATERIAL/COLOR

BASE MATERIAL/COLOR

WALL MATERIAL/COLOR

GCWT-1

CEILING MATERIAL/COLOR

PVCT-1

OR APPROVED EQUAL

457.2MMx457.2MM, 3MM THK

KCC SENSE TILE, CERAMIC, TN2412C

PVC TILE

ACST-1

OR APPROVED EQUAL

WHITE

MC 3102 (3S)

"KCC MITONE"

603MM x 603MM x 15MM THK

ACOUSTICAL CEILING TILE

PVC TILE

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

EXST

MAT'L

NEW

MAT'L

NEW

MAT'L

EXST

VCBPVCT VCB

PVCT

F.F.

F.F.

F.F.

PVCT-1 F.F. VCB-1

GWB GWB*

GWB

PAINT

PAINT

PAINT

GWB* : WATER RESISTANT TYPE

BEDROOM VCT

VCT

CMT

PVCT-1 VCB VCB PAINT PT-1 GWB

AWP ACOUSTIC WALL PANEL

FINISH SCHEDULE NOTES :

MANUFACTURERS STANDARD MUST APPROACH.

COLOR IS NOT REQUIRED. THE SELECTIONS SERVE ONLY TO INDICATE THE COLOR WHICH THE

INTENDED TO LIMIT SELECTIONS OF PRODUCTS. AN EXACT MATCH OF THE MANUFACTURERS

MANUFACTURERS' COLORS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY AND ARE NOT

USER AGENCY.

SELECTION OF INTERIOR PAINT AND FACTORY APPLIED COLORS SHALL BE APPROVED BY

SHALL BE WATERPROOF TYPE GWB.GWB FOR TOILETS, AND OTHER WET AREAS

F.F. VCB-1

BATHROOM

VCB VCB F.F. VCB-1 GWB GWB* PAINT 2400CONC PAINT PT-1

GWB GWB* PAINT 2400

CMU

PAINT PT-1CMU

F.F.

GWB* : WATER RESISTANT TYPE

VAR

CONC

CMU

CMU

GCWT

CMU

PAINT PT-1

GCWT F.F. GCWT-1

PAINT PT-1

CMU

CMU

PAINT PT-1CMU

PT-2

PT-2

FT FT-1

FT-1

OR APPROVED EQUAL

NON-SLIP, 300 x 300 x 8 THK

FG 7L67-1, MARON

DONGSEO, INUS

NON-SLIP CERAMIC FLOOR TILE

* GROUT COLOR FOR GCWT

OR APPROVED EQUAL

: MOLD & MILDEW RESISTANT, STAIN PROOF

ANTIQUE WHITE

OR APPROVED EQUAL

300 x 600 x 10 THK

LQR IN92-1, GLOSS

DONGSEO, INUS

GLAZED CERAMIC WALL TILE

CB CEMENT BOARD

FT FLOOR TILE

VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1VCT CMU PAINT PT-1

PAINT PT-1CMUVCT PVCT F.F. PVCT-1 VCB VCB F.F. VCB-1

AND MATERIAL & COLOR SCHEDULE

INTERIOR/ EXTERIOR FINISH SCHEDULE

101A&B~102A&B

201A&B~214A&B

301A&B~314A&B

401A&B~414A&B

DRESSING

111,112,115

103,106C,110, PAINT 3050CMU CONCCOATINGCONC VCB VCB F.F. VCB-1 PAINT PT-1 -

113A&B

C.Q.

VEST

118,217,317,417 LAUNDRY

STAIR-1&2

120,219,319,419 CORRIDOR

VEST

113,122,216,316,416

MECH RM

MALE&FEMALE LATRINE

318A&B,418A&B

119A&B,218A&B, VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1VCT CMU PAINT PT-1

VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1 2400VCT CMU PAINT PT-1

VCBPVCT VCBF.F. PVCT-1 F.F. VCB-1VCT CMU PAINT PT-1114,123,215,315,415

AREA,T.O,R.O,CO,XO,COMM,

OFFICE, ADMIN OFFICE,WAIT

& DAY RM

MULTI-PURPOSE RM

107,108,109

104,105,106,106A&B

EPOXY

COATINGEPOXY

F.F.CMT FT FT-1

QT QT F.F. QT-1

COATINGEPOXY

- RT RT-1

QT QT F.F. QT-1

F.F.

VCB VCB F.F. VCB-1

F.F.- RT RB-1

F.F.

QTB QTB QTB-1

QTB QTB QTB-1

-JANITOR

GCWT GCWT F.F. GCWT-1

PAINT PT-1

CPL

2400PT-2

PT-2

PT-2

PT-2

EP-1

EP-1

EP-1

ACST ACST F.F ACST-1

2400ACST ACST F.F ACST-1

PAINT 3050CONC - PT-2

2400ACST ACST F.F ACST-1

GWB PAINT 2400PT-2CPL

GWB* PAINT 2400PT-2CPL GWB* : WATER RESISTANT TYPE

- - PAINT PT-2

2400ACST ACST F.F ACST-1

GWB PAINT 2400PT-2CPL

- - - - 3050

GWB* : FIRE RESISTANT TYPE

- / GWB

QT-1

#Q06,FAWN GRAY

152X152X12THK

AMERICAN OLEAN

W/ ABRASIVE GRAIN

QUARRY TILE

AMERICAN OLEAN

QTB-1

#Q06,FAWN GRAY

COVE ROUND TOP

127X152X12THK

QUARRY TILE BASE

- / GWB

125 SPRINKLER ROOM

-/GWB*

PAINT 3050CMU CONCVCB VCB F.F. VCB-1 PAINT PT-1 - PT-2

GWB* : FIRE RESISTANT TYPE

COATINGCONC EPOXY EP-1

RT-1 RUBBER TILE

OR APPROVED EQUAL

I-BADAK FLOORING SYSTEM

CMR42 FOR FLOOR, 3THK

SCOR42 FOR TREAD/RISER, 3THK

RM 4200 FOR STRINGER, 2THK

EP-1

ABRASIVE GRAIN FINISH

OR APPROVED EQUAL

CLEANPOXY 3100

NOROO PAINT & CO

EPOXY PAINT

VCB-1

RB-1 RUBBER BASE

OR APPROVED EQUAL

RM 4200, 2THK

OR APPROVED EQUAL

DARK BROWN 100HGT, 3THK

LG HAUSYS

VINYL COVE BASE

PT-1

OR APPROVED EQUAL

EX8816-PALEBEIGE

KCC SUPRO HOME AND WELLBEING

LATEX, INTERIOR

ANTI-MOLD AND MILDEW

PAINT PT-2

OR APPROVED EQUAL

EX8816-N/WHITE

KCC SUPRO HOME AND WELLBEING

LATEX, INTERIOR

ANTI-MOLD AND MILDEW

PAINT

CMU

105A, 126 STORAGE, COMM RM

SUPPLY RM,COMMO SHOP

STORAGE,NBC RM,

A-15

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

REMARKS

DOOR DIMENSION

WIDTH

MATERIAL

D1

DOOR

TYPE

DOOR

NOS.

ROUGH OPENING

WIDTH HEIGHT

HDW

SET

THICKHEIGHT NO (HR)

RATED

FIRE

LOUVERGLAZING

CUT

UNDER

FRAME

D2

D3

D4

D5

D6

D7

D8

D9

D10

DOOR

DOOR / WINDOW / LOUVER SCHEDULE

D11

D12

D13

D14

D15

KEY BOX : WALL MOUNTED KEY BOX E83513.

COORDINATING WITH THE USER FOR APPROVAL BY COR.

THE CONTRACTOR SHALL SUBMIT MASTER KEYING CHART,

APPROVAL

AND WINDOW SCHEDULE AND DETAIL DRAWING TO COR FOR

CONTRACTOR SHOULD SUBMIT SHOP DRAWING FOR ALL DOOR

CONNECTED TO STRUCTURE WITH ANCHOR BOLT AND WELDING.

ALL EXTERIOR DOOR FRAME AND WINDOW FRAME SHOULD BE

AND UFC 4-010-01, PAG B-9 & 10, PARA B-3.1 THRU B-3.1.4

ALL EXTERIOR DOOR, GLAZED WINDOW: SEE SEPC SECTION 08391;

4.

5.

6.

8.

7.

HEAT GAIN AND FIRERATED.

WHITE OR LIGHT BEIGE TO MAXIMIZE REFLECTANCE AND MINIMIZE

BE EQUIPPED WITH HORIZONTAL MINI BLINDS. COLOR SHALL BE

WINDOWS IN ALL AREAS WHERE FUNCTIONALLY WARRANTED SHALL

1.

2.

NATURAL COLOR FINISH W/ QUARTER SLICED OAK.

ALL WOOD FLUSH DOORS SHALL BE FINISHED FACTORY COATED

FABRICATION AND INSTALLATION

SHALL BE APPROVED BY THE CONTRACTING OFFICER BEFORE

DOORS AND ALUMINUM WINDOWS AS ACTUAL SIZE, AND DRAWINGS

THE CONTRACTOR SHALL PREPARE SHOP DRAWINGS FOR ALL

DOOR & WINDOW NOTES

HIGH QUALITY AND GRADE PRODUCTS WITH APPROVAL TO COR.

& QUALITY ARE NOT REQUIRED. BUT CONTRACTOR SHALL INSTALL

AN EXACT MATCH OF THE MANUFACTURERS FUNCTION, GRADE, COLOR,

AND ARE NOT INTENDED TO LIMIT SELECTIONS OF PRODUCTS.

MANUFACTURERS LISTED ARE FOR IDENTIFICATION PURPOSES ONLY

-4EA OF AA BATTERIES PER EACH LOCKSET

INTO USING AGENCY

-ADDITIONALLY 20% OF BLANK CARD KEYS SHALL BE TURNED

-O&M TRANING TO DPW BY MANUFACTURER

-MASTER KEY SYSTEM

-CARD KEYED TYPE WITH 3EA CARD KEYS & PROGRAM

-SELF LOCKING

ONITY, MAGSTRIPE HT24 OR APPROVED EQUAL

ELECTRONIC CARD KEYED LOCKSET,

DOOR / WINDOW / LOUVER ELEVATION

WINDOW BLIND SHALL BE EQUIPPED TO ALL EXTERIOR WINDOWS.

L 700900ALAL - - -

L 400700ALAL - - -

L 300400ALAL - - -

( SHGC : MAX 0.4 )

+ 6 THK TINTED LOW-E TEMPERED GLASS

+ 12 THK AIR SPACE

: 8.75 THK CLEAR LAMINATED GLASS

TYPICAL INSULATED/LAMINATED GLASS FOR WINDOWS

(ANODIZED DARK BRONZE)

AL BLAST WINDOW

(THERMAL BREAK TYPE)

SLIDING

W/ INSECT SCREEN

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

I

FIX

D16

D17

D18

D19

I

GLASS AL 1016 710

GLASS AL 1220 900 142- -

* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASSW1

W2

I

GLASS AL 1220 890

GLASS AL 1420 1320 142- -

- -I

* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS

W4

GLASS AL 1016 1473 - -W5

1000 1200 - -KR1 -

W3

LAMINATED

WINDOW GLASS

LAMINATED AL

W/ 1HR FIRE RATED

FIN FL

SHUTTER HOOD

OVERHEAD COILING

(BY MFR)

1 FIRE RATED

OVERHEAD COILING SHUTTER

W/ FUSIBLE LINK

J OVERHEAD COILING SHUTTER

W/ FUSIBLE LINK

K

FIN FL

REAR ELEVATION

SLIDING & FIXED

(TYP)

44.5METAL METALD 2185 21331930 1830

44.5METAL METALB 1016 2185 915 2133 2 1)100X600 - -- 1) INSULATED GLASS

1 - -4-600X600 -

44.5METAL METALC 2185 2133 3 - -1)100X6001016 915 1) FIRE RATED GLASS

44.5METAL METALC 2185 2133 4 -1)100X6001016 915 - 1) FIRE RATED GLASS

915METAL 21851016 44.52133 5 - - - 1/3A WOOD

44.5 15WOOD METAL 6 - - -A 813 2185 711 2133

44.5METAL METALC 2185 2133 7 - - 3/4-813 712

44.5METALC 2185 2133 8 - - -1016 915

44.5WOOD METALA 2185 2133 8 - - 3/41)100X6001016 915 1) FIRE RATED GLASS

44.5METAL METALB 1016 2185 915 2133 2 1)100X600 - -- 1) INSULATED GLASS

44.5METAL METALC 2185 2133 9 - - 3/4-1016 915

44.5WOOD METALA 2185 2133 10 - 15-813 712

44.5WOOD METALA 2185 21331016 915 - -- -8

44.5METAL METALC 2185 2133 9 - - 3/4-1016 915

44.5WOOD METALA 2185 21331016 915 - --8

44.5METAL METALD 1930 2185 1830 2133 1 - - - -

35 -WOOD WOOD 11 - - -F 1000 2185 900 2085

G / H 2108 1)1245 1) 1)

CLASS 5 SECURITY

DOOR

G H DAY GATE OF CLASS 5

SECURITY DOOR

(BY SECURITY DOOR MFR)(BY SECURITY DOOR MFR)

DAY GATE

1016 2185

METAL DOOR

THERMAL INSULATED

METAL HOLLOWC

B

CORE DOOR

E

MET DOOR

THERMAL INSULATED

D

WOOD SOLID DOOR

(NATURAL

FACTORY FINISH)

A

150150600

LIGHT

VISIONVISION

LIGHT

100150

WOOD SOLID DOORF

(NATURAL FACTORY FINISH)

SCHEDULED

LOUVER AS

(TYP)

-12 - - -

METAL METAL

J / K

I * MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS

* MINI-BLIND, TYPICAL INSULATED/LAMINATED GLASS

L2

L3

L1

* ROLL UP SHUTTER WITH COUNTER TOP

100100

W/ BIRD SCREEN

AL LOUVER

L

& INSECT SCREEN

1HR FIRE RATED

THERMAL INSULATED

METAL BLAST DOOR

W/ METAL FRAME

- PEAK REFLECTED PRESSURE

: 40.6 KPA

- PEAK IMPULSE

: 210 KPA-MS

10.

METAL

1) BY ARMORY DOOR MFR

1) SOUNDPROOF DOOR, STC-25

1) WOODEN DOORWAY MOLDING, OAK, NATURAL FINISH

AND NOTES

DOOR / WINDOW SCHEDULE, ELEVATIONS,

* ROLL UP WINDOW WITH COUNTER TOP

* LAMINATED GLASS, 10.75 THK

- WDMA TM-8 HINGE LOADING TEST METHOD

- WDMA TM-7 CYCLE SLAM TEST METHOD

INDICATED ON SECTION 08 14 00, WOOD DOORS, 2014 O&MA SPECIFICATIONS.

SHALL SUBMIT CERTIFICATIONS AND TEST REPORTS FOR APPROVAL AS

ALL WOOD DOORS SHALL BE TESTED AS FOLLOWING,AND CONTRACTOR

11.

9.

12.ALL DOOR HARDWARE SHALL BE MET ANSI/BHMA.

METAL METAL

D20

M

METAL DOOR

THERMAL INSULATED

M 44.5METAL METAL 2185 2133 13 - --1016 915

& KEY OVERRIDE

ELECTRONIC CARD

KEYED LOCKSET

WITH BATTERY

SOUND PROOF SEAL1

THRESHOLD J32100

HINGES A2112 114X114

DOOR STOP L02161

KICK PLATE J102, SST

CLOSER CO2011

MARBLE THRESHOLD

DOOR STOP L02161

PRIVACY 4000-1 (F76)

HINGES A8112 114X114

HDW-6

HDW-5

1 DOOR VIEWER LO3221

(L-FUNCTION)

HDW-2

EXIT DEVICE TYPE-1,

(LEVER TYPE HANDLE)

FUNCTION 08

DOOR STOP LO2161

HINGES 8112 114X114

HDW-10

1 CLOSER CO2011

1 KICK PLATE J102, SST

THRESHOLD J321001

HDW-4

HINGES 8112 114X114

(LEVER TYPE HANDLE)

LOCKSET 1000-1, F01

DOOR CLOSER CO20111

1 DOOR STOP LO2161

THRESHOLD J32100

KICK PLATE J102, SST

ASTRAGAL

HDW-1

HINGES 2133 114X114, NRP

1 LOCKSET 1000-1 F07

FLUSH BOLT LO40812

AUTOMATIC DOOR BOTTOM

ROY 335

SOUNDPROOF SEAL1

HDW-9

HINGES A2112, 114x114 (NRP)

1 THRESHOLD J32100

CLOSER CO2011

KICK PLATE J102, SST1

DOOR STOP LO21611

LOCKSET 1000-1 F071

HINGES 8112 114X114

HDW-3

HINGES 8112 114X114

1 EXIT DEVICE TYPE-1

1 DOOR STOP LO2161

1 KICK PLATE J102, SST

CLOSER CO2011

THRESHOLD J321001

FUNCTION 08

(UNLOCK KNOB)

HDW-8

WEATHER STRIP & SEAL

1 THRESHOLD J32100

HDW-7

HINGES 8112 114X114

KEYED LOCKSET

WITH BATTERY

ELECTRONIC CARD

& KEY OVERRIDE

DOOR CLOSER CO20111

1 DOOR STOP LO2161

KICK PLATE J102, SST1

THRESHOLD J321001

(LEVER TYPE HANDLE)

(LEVER TYPE HANDLE)

1 DOOR CLOSER C02021

HDW-11

HINGES A2112 101X101

FLUSH BOLT L042012

1 DOOR PULL J401

DUST PROOF STRIKE L040111

KICK PLATE J102, SST1

DOOR STOP LO2161

HINGES 8112 114X114

1 CLOSER CO2011

1 KICK PLATE J102, SST

THRESHOLD J321001

A-16

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

H A R D W A R E S C H E D U L E

P L A NS E C T I O N

EYEBOLT

HOOK &

DOOR

STEEL TUBE

50 x 50 x 6 THK STEEL

80x80x3.2 THK

WALL TYPE BUMPER L02101

GALV STEEL TUBE

(FILLED W/CONC)

PLATE WELDED TO

(2 EA)

DOOR

STEEL TUBE

CONC STOOP

WELDED TO

STEEL PLATE

50 x 50 x 6THK

FOUNDATION

STEEL PLATE

STEEL TUBE

CONCRETE

170 x 170 x 6THK

WELDED TO

HOOK & EYEBOLT

CONC)

GALV STEEL

80x80x3.2 THK

WALL TYPE BUMPER L02101

YELLOW STRIPS

BLACK BACKGROUND

TUBE (FILLED W/

250X250

HARDWARE SCHEDULE AND DETAILS

HDW-12

DOOR STOP L021611

MECHANICAL

LOCK FF-L-2937

SCALE:

1/10

DOOR STOP & HOLDER DETAILS

(LOCK DRESSING RM SIDE)

MORTISE BOLT, L04121

PRIVACY 4000-1 (F82)

PUSH PLATE

PULL PLATE

DEAD BOLT E0161

DOOR STOP & HOLDER

11 DOOR STOP & HOLDER

HDW-13

HINGES 2133 114X114, NRP

1 LOCKSET 1000-1 F07

DOOR STOP & HOLDER

WEATHER STRIP & SEAL

THRESHOLD J32100

KICK PLATE J102, SST1

A-17

SIGNAGES SCHEDULE

A

B C D

E F G H

SYMBOL BY

DESIGNED BY

ENERGY MANAGER

SUBMITTED BY

USING AGENCY

APPROVED BY

PROJECT NO. DRAWING NO. REF NO.

SCALE :

ZONE DATE APVD.

UTILITIES

SHEET OF

REVIEWED BY

DESCRIPTION

BLDGS & GROUNDS

CHIEF, ENGR'G DIV

DES

CHK'D

REVISIONS

IMCOM

FIRE & EMERGENCY SVC

SAFETY

ENVIRONMENT

UNIT #15707, APO AP 96258-5707

ENGINEERING DIVISON, DPW, USAG-RED CLOUD

HEADQUARTERS, UNITED STATES ARMY GARRISON, RED CLOUD

US ARMY INSTALLATION MANAGEMENT COMMAND

DEPARTMENT OF THE ARMY

ARCHITECTURAL

BUILDING IDENTIFICATION 1A 2A

M E S S A G E DETAILELEVATION QUANTITY

ELEVATIONM E S S A G E

DETAIL QUANTITY

LIVING UNIT ROOM

IDENTIFICATION

COORDINATED WITH THE CONTRACTING

4. SIGN MESSAGE COPY WILL BE

OFFICER AND USING AGENCY

BY THE SITE ADAPT CONTRACTOR

HOLDER

CARD

CORRIDOR SIDE

BROWN

BACKGROUND

LETTERS

WHITE

NOTE : ROOM NUMBERS SHALL BE AS

SHOWN ON FLOOR PLAN

FIN. FL

FINISH SYSTEM

EXT.INSUL &

STEEL BOLT

8 PER SIGN

ALUM. SLEEVE

MASTIC

COMPOUND

6 THK ALUM PLATE

WOOD NAILER W/

50 W x T, 1,200

Laundry

AND BULLETIN BOARD SCHEDULE

NOTE : FOR ALTERNATE MESSAGE SEE SIGNAGE

(SEE NOTES 1)

WHITE LETTERS

BACKGROUND

BROWN

FIN. FL

C A

P

1220112

75225

1220112

BUILDING IDENTIFICATION

D E T A I L D E T A I L D E T A I L

DOUBLE EMULSION

FOAM TAPE

PICTOGRAPH

LETTERS &

ALL AROUND

POLISH EDGES

ACRYLIC BACKING

BOARD W/SCREW

@ WALL ONLY

(DO NOT USE

@ FIRE-RATED DOOR)

NOTE : CARD INSERTS PROVIDED

HOLDER

AL CARD

BY USING AGENCY

FOAM TAPE

DOUBLE EMULSION

W/ SCREW

BACKING BOARD

ACRYLIC

ROOM IDENTIFICATION MISC IDENTIFICATION

100225

5012050

REMARKS REMARKS

VIEWER

R20

DOUBLE EMULSION

FOAM TAPE

REAR VIEWFRONT VIEW

ACRYLIC

CLEAR 2THK

ACRYLIC

WHITE 2THK

ACRYLIC

CLEAR 2THK

SECTION

R20

INSIDE ROOM

4 4

FLEXI-INFO

EQ220EQ

ACRYLIC

WHITE 2MM THK

ACRYLIC

CLEAR 2MM THK 1

222 2

BED RM DOOR

DOOR ELEVATION

DOOR

PLEXI-INFO HOLDER

SIZE & MOUNTING LOCATION OF SIGNAGE

SCALE: N/A

1A 1B 1C

2A 2B 2C

SCALE:

N/A

1&2

PLEXI-INFO HOLDER DETAILS @ BED RM

1B 2B

DAY ROOM

1C 2C1B

1C 2C1B

1C 2C1B

1C 2C1B

1C 2C1B

1C 2C1B

3 3

Laundry

2C

1. BUILDING IDENTIFICATION NUMBER

; CONTRACTOR SHALL VERIFY NUMBER, COLOR, SIZE

1ST FL

AND HGT OF LOCATION WITH DPW

2. NOS. ARE TWO PLACES PER EACH BUILDING.

3. SEE ELEVATION FOR LOCATION.

NOTE

EXT FIELD

IS TO MATCH

LETTER COLOR

WALL COLOR

MATCH

COLOR IS TO

BACKGROUND

ROOF COLOR

S-0000 S-0000

V E

R

IF

Y

T

MECH RM

1 PER EACH LIVING ROOM

3A 3B 3C 3D

STORAGE

COMM RM

LAUNDRY

OFFICE 1 PER EACH OFFICE MALE&FEMALE LATRINE 2

1 PER EACH LIVING ROOM

1 PER EACH DAY RM

1 PER EACH STORAGE

1 PER EACH LAUNDRY

STAIR-1&2 1C 2C1B 1 PER EACH STAIR

C.Q. 11C 2C1B

EQ EQ

12 126 12

150 150

12612 12

,6

C A

P

Men Women

FIN. FL.

MISC IDENTIFICATION1D

2C1D

201a a

000000-Repair Barracks-A1
000000-Repair Barracks-A2
000000-Repair Barracks-A3
000000-Repair Barracks-A4
000000-Repair Barracks-A5
000000-Repair Barracks-A6
000000-Repair Barracks-A7
000000-Repair Barracks-A8
000000-Repair Barracks-A9
000000-Repair Barracks-A10
000000-Repair Barracks-A11
000000-Repair Barracks-A12
000000-Repair Barracks-A13
000000-Repair Barracks-A14
000000-Repair Barracks-A15
000000-Repair Barracks-A16
000000-Repair Barracks-A17

File details come from the government source that posted it. Updated .