This is an Asbestos Inspection Report for Building AS217 at MCB Camp Lejeune, dated August 14, 2025. The building, constructed in 1954 and currently occupied as an Administration facility, has been assigned a hazard ranking of 0/Blue with no asbestos-containing materials (ACM) identified during the initial April 2007 assessment. A subsequent renovation conducted circa 2005/2006 included additional sampling that confirmed no ACM presence.
The report documents multiple asbestos-containing materials that were identified and tested as non-friable ACM or removed materials, including 12" white and beige floor tiles with adhesive, base cove/mastic, 2'x2' ceiling tiles, stair treads, pipe insulation, sealants, built-up roofing, and gypsum board walls with joint compound. These materials are located throughout the building across rooms 100-320, stairs 1-3, and mechanical spaces, with initial identification dates ranging from September 1999 to April 2007. All collected samples tested negative for asbestos content (0% chrysotile, amosite, and other asbestos types), with the exception of one built-up roofing sample that contained 9% asbestos. The Camp Lejeune Asbestos Program Manager (910-451-5837) maintains custody of the survey and conducts periodic inspections. Building occupants are instructed to avoid disturbance of any remaining materials and report any damage or changes in material condition to the Program Manager.
View the file
Other files
Show all 33
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ASBESTOS INSPECTION REPORT of:
Building # AS217
MCB CAMP LEJEUNE
Thursday, August 14, 2025
Print Date
Thursday, August 14, 2025 Page 1 of 5Print Date:
INSPECTION SUMMARY
BLDG #:
OCCUPANT:
YEAR BUILT:
BUILDING COMMENTS:
AS217
ADMINISTRATION
HAZARD RANKING 0/BLUE;NO ACM IDENTIFIED [AH APR07]:
RI APR 07:
RENOVATION CIRCA 2005/2006. ADDITIONAL SAMPLES TAKEN, NO ACM IDENTIFIED.
ASBESTOS MANAGER: 910-451-5837
Friable ACM(s) identified
Non-friable ACM(s) identified
Tested Non ACM or REMOVED Materials
DESCRIPTION LOCATION Date
NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.
DESCRIPTION LOCATION Date Quantity
DESCRIPTION LOCATION Date Quantity
No friable ACM records found in database
No non friable ACM records found in database
NOTIFICATION OF ACM IN BUILDING
12" WHITE FLOOR TILE AND ADHESIVE 100, 200, 207, 300, STAIRS 1 - 3 9/27/1999
PIPE INSULATION SEALANT 1ST FLOOR 4/26/2007
BASE COVE/MASTIC, 100 - 105, 107 - 109, 111, 113 - 120, 200 -
205, 207, 209 - 217, 300 - 303, 305, 307 - 317, STAIRS 1 - 3
9/27/1999
2'x2' CEILING TILE, 100 - 105, 107 - 109, 111, 113 - 120, 200 -
205, 207, 209 - 217, 300 - 303, 305, 307 - 317
9/27/1999
INTERIOR CAULKING, 1ST FLOOR 4/26/2007
FLOOR TILE AND ADHESIVE, UNDER OTHER 3RD FLOOR HALLWAY 2/25/2000
PIPE INSULATION SEALANT 1ST FLOOR 4/26/2007
12" BEIGE FLOOR TILE AND ADHESIVE STAIR 3 (FIRST FLOOR) 9/27/1999
MISCELLANEOUS SEALANT 3RD FLOOR 4/26/2007
ADHESIVE 3RD FLOOR 4/26/2007
STAIR TREAD/MASTIC STAIRS 1 - 3 9/27/1999
Thursday, August 14, 2025 Page 2 of 5Print Date:
ACM only presents a health hazard when asbestos fibers are airborne and inhaled.
Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.
HEALTH ASPECTS:
Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.
CONDITIONS TO AVOID:
Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos
Program Manager.
REPORTS OF DAMAGE:
Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:
ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:
The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.
RECORDKEEPING:
CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837
BUILT-UP ROOFING ROOF 9/27/1999
GYPSUM BOARD WALLS (WITH
ASSOCIATED JOINT COMPOUND)
100 - 109, 111, 113 - 120, 200 - 205, 207, 209 - 217, 300 - 303, 305, 307 - 317
9/27/1999
PIPE INSULATION 1ST FLOOR MEN'S ROOM 6/21/2000
BUILT-UP ROOFING ROOF 4/26/2007
12" WHITE FLOOR TILE AND ADHESIVE 100, 200, 207, 300, STAIRS 1 - 3 4/26/2007
PIPE INSULATION 1ST FLOOR 4/26/2007
Thursday, August 14, 2025 Page 3 of 5Print Date:
SAMPLES COLLECTED
Sample Sample
Date
HA Sample Location Chr
Amo
Oth
Description
AS214-01-42RI07 4/26/200701 1ST FLOOR,STAIRWELL 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS214-01-43RI07 4/26/200701 1ST FLOOR,STAIRWELL 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS217-01-01 9/27/199901 100 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS217-01-02 9/27/199901 STAIR 2 (FIRST FLOOR) 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS217-01-03 9/27/199901 STAIR 2 (SECOND FLOOR) 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS217-01-40RI07 4/26/200701 2ND FLOOR,HALLWAY 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS217-01-41RI07 4/26/200701 2ND FLOOR,STAIRWELL 0 0 012" WHITE FLOOR TILE
AND ADHESIVE
AS217-01-RI02 11/7/200201 N/A12" WHITE FLOOR TILE
AND ADHESIVE
AS217-02-01 9/27/199902 STAIR 3 (FIRST FLOOR) 0 0 012" BEIGE FLOOR TILE
AND ADHESIVE
AS217-02-02 9/27/199902 STAIR 3 (FIRST FLOOR) 0 0 012" BEIGE FLOOR TILE
AND ADHESIVE
AS217-02-03 9/27/199902 STAIR 3 (FIRST FLOOR) 0 0 012" BEIGE FLOOR TILE
AND ADHESIVE
AS217-03-01 9/27/199903 STAIR 2 (FIRST FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK
AS217-0301QC 9/27/199903 STAIR 2 (FIRST FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK
AS217-03-02 9/27/199903 STAIR 2 (SECOND FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK
AS217-03-03 9/27/199903 STAIR 3 (SECOND FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK
AS217-04-01 9/27/199904 107 0 0 0BASE COVE/MASTIC, BLACK
AS217-04-02 9/27/199904 200 0 0 0BASE COVE/MASTIC, BLACK
AS217-04-03 9/27/199904 STAIR 1 (THIRD FLOOR) 0 0 0BASE COVE/MASTIC, BLACK
AS217-05-01 9/27/199905 105 0 0 02'x2' CEILING TILE, FISSURED
AS217-0501QC 9/27/199905 105 0 0 02'x2' CEILING TILE, FISSURED
Thursday, August 14, 2025 Page 4 of 5Print Date:
Sample Sample
Date
HA Sample Location Chr
Amo
Oth
Description
AS217-05-02 9/27/199905 200 0 0 02'x2' CEILING TILE, FISSURED
AS217-05-03 9/27/199905 314 0 0 02'x2' CEILING TILE, FISSURED
AS217-06-00RI07 4/26/200706 N/A 9 9 9BUILT-UP ROOFING
AS217-06-RI02 11/7/200206 N/ABUILT-UP ROOFING
AS217-07-01 9/27/199907 100 0 0 0GYPSUM BOARD WALLS
(WITH ASSOCIATED
JOINT COMPOUND)
AS217-07-02 9/27/199907 200 0 0 0GYPSUM BOARD WALLS
(WITH ASSOCIATED
JOINT COMPOUND)
AS217-07-03 9/27/199907 300 0 0 0GYPSUM BOARD WALLS
(WITH ASSOCIATED
JOINT COMPOUND)
AS217-51-40RI07 4/26/200751 MECH ROOM 0 0 0PIPE INSULATION
AS217-60-40 4/26/200760 HALLWAY 0 0 0MISCELLANEOUS
SEALANT
RED,AROUND WIRES
AS217-61-40 4/26/200761 HALLWAY 0 0 0ADHESIVE CEILING TILE HANGER
AS217-62-40 4/26/200762 MECH ROOM 0 0 0PIPE INSULATION
SEALANT
TAN
AS217-63-40 4/26/200763 MECH ROOM 0 0 0PIPE INSULATION
SEALANT
GRAY
AS217-64-40 4/26/200764 MECH ROOM 0 0 0INTERIOR CAULKING, DOOR
274-B-1 2/25/2000B1 BLACK TILE 3RD FLOOR
HALLWAY
5 0 0FLOOR TILE AND
ADHESIVE, UNDER
OTHER
275-B-1 2/25/2000B1 BLACK MASTIC 3RD FLOOR
HALLWAY
3 0 0FLOOR TILE AND
ADHESIVE, UNDER
OTHER
276-B-1 2/25/2000B1 WHITE TILE 3RD FLOOR
HALLWAY
0 0 0FLOOR TILE AND
ADHESIVE, UNDER
OTHER
277-B-1 2/25/2000B1 YELLOW MASTIC 3RD FLOOR
HALLWAY
0 0 0FLOOR TILE AND
ADHESIVE, UNDER
OTHER
Thursday, August 14, 2025 Page 5 of 5Print Date: