AS217 ACM REPORT.pdf

PDF 42 KB Posted

Attached to
MCAS Multiple Building Painting/Flooring Repairs
Solicitation number
N4008526R9069
Issued by

About this file

This is an Asbestos Inspection Report for Building AS217 at MCB Camp Lejeune, dated August 14, 2025. The building, constructed in 1954 and currently occupied as an Administration facility, has been assigned a hazard ranking of 0/Blue with no asbestos-containing materials (ACM) identified during the initial April 2007 assessment. A subsequent renovation conducted circa 2005/2006 included additional sampling that confirmed no ACM presence.

The report documents multiple asbestos-containing materials that were identified and tested as non-friable ACM or removed materials, including 12" white and beige floor tiles with adhesive, base cove/mastic, 2'x2' ceiling tiles, stair treads, pipe insulation, sealants, built-up roofing, and gypsum board walls with joint compound. These materials are located throughout the building across rooms 100-320, stairs 1-3, and mechanical spaces, with initial identification dates ranging from September 1999 to April 2007. All collected samples tested negative for asbestos content (0% chrysotile, amosite, and other asbestos types), with the exception of one built-up roofing sample that contained 9% asbestos. The Camp Lejeune Asbestos Program Manager (910-451-5837) maintains custody of the survey and conducts periodic inspections. Building occupants are instructed to avoid disturbance of any remaining materials and report any damage or changes in material condition to the Program Manager.

View the file

Other files

File Type Posted
25-0453 Amend 0002 and Cont page.pdf PDF
25-0453 Amend 0001.pdf PDF
Combined DIV 01 SPECS.pdf PDF
Building AS4108 FLRPLN.pdf PDF
MCAS SOW.pdf PDF
26M101CN BEQ HP301 Paint-Flooring Repairs PD.pdf PDF
09 90 00 Painting and Coating Spec.pdf PDF
Building A66 FLRPLN.pdf PDF
Combined DIV 01 DBB SPECS.pdf PDF
26M101CN BEQ HP301 Paint-Flooring Repairs FLRPLN.pdf PDF
26M101CN BEQ HP301 Paint-Flooring Repairs PS.pdf PDF
Contractor Environmental Guide Updated Format_20231009 with ESOP.pdf PDF
HP301 SR.pdf PDF
09 68 00 Carpeting Spec.pdf PDF
25M114CN MCAS Multiple Building Paint and Flooring Repairs SOW.pdf PDF
25M114CN MCAS Multiple Building Paint and Flooring Repairs PD.pdf PDF
G640 ACM REPORT.pdf PDF
Contractor Environmental Guide.pdf PDF
25M114CN MCAS Multiple Building Paint and Flooring Repairs SR.pdf PDF
26M101CN BEQ HP301 Paint-Flooring Repairs FS.pdf PDF
Building AS217 FLRPLN.pdf PDF
09 65 00 LVT Spec.pdf PDF
AS236 ACM REPORT.pdf PDF
09 90 00 PAINTS COATINGS Spec..pdf PDF
Building G640 FLRPLN.pdf PDF
26M101CN BEQ HP301 Paint-Flooring Repairs SR.pdf PDF
25-0453 RFP and pricing sheet.pdf PDF
09 65 00 RESILIENT FLOORING SPECS.pdf PDF
26M101CN BEQ HP301 Paint-Flooring Repairs QD.pdf PDF
Building AS236 FLRPLN.pdf PDF
Building G920 FLRPLN.pdf PDF
AS4108 ACM REPORT.pdf PDF
Building RR465 FLRPLN.pdf PDF
Show all 33

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ASBESTOS INSPECTION REPORT of:

Building # AS217

MCB CAMP LEJEUNE

Thursday, August 14, 2025

Print Date

Thursday, August 14, 2025 Page 1 of 5Print Date:

INSPECTION SUMMARY

BLDG #:

OCCUPANT:

YEAR BUILT:

BUILDING COMMENTS:

AS217

ADMINISTRATION

HAZARD RANKING 0/BLUE;NO ACM IDENTIFIED [AH APR07]:

RI APR 07:

RENOVATION CIRCA 2005/2006. ADDITIONAL SAMPLES TAKEN, NO ACM IDENTIFIED.

ASBESTOS MANAGER: 910-451-5837

Friable ACM(s) identified

Non-friable ACM(s) identified

Tested Non ACM or REMOVED Materials

DESCRIPTION LOCATION Date

NOTICE: The following asbestos-containing materials have been identified in this structure. Refer to survey findings for additional information or contact the Asbestos Program Manager. Please note ACM that is intact and undisturbed is not considered a significant health hazard to building occupants.

DESCRIPTION LOCATION Date Quantity

DESCRIPTION LOCATION Date Quantity

No friable ACM records found in database

No non friable ACM records found in database

NOTIFICATION OF ACM IN BUILDING

12" WHITE FLOOR TILE AND ADHESIVE 100, 200, 207, 300, STAIRS 1 - 3 9/27/1999

PIPE INSULATION SEALANT 1ST FLOOR 4/26/2007

BASE COVE/MASTIC, 100 - 105, 107 - 109, 111, 113 - 120, 200 -

205, 207, 209 - 217, 300 - 303, 305, 307 - 317, STAIRS 1 - 3

9/27/1999

2'x2' CEILING TILE, 100 - 105, 107 - 109, 111, 113 - 120, 200 -

205, 207, 209 - 217, 300 - 303, 305, 307 - 317

9/27/1999

INTERIOR CAULKING, 1ST FLOOR 4/26/2007

FLOOR TILE AND ADHESIVE, UNDER OTHER 3RD FLOOR HALLWAY 2/25/2000

PIPE INSULATION SEALANT 1ST FLOOR 4/26/2007

12" BEIGE FLOOR TILE AND ADHESIVE STAIR 3 (FIRST FLOOR) 9/27/1999

MISCELLANEOUS SEALANT 3RD FLOOR 4/26/2007

ADHESIVE 3RD FLOOR 4/26/2007

STAIR TREAD/MASTIC STAIRS 1 - 3 9/27/1999

Thursday, August 14, 2025 Page 2 of 5Print Date:

ACM only presents a health hazard when asbestos fibers are airborne and inhaled.

Avoid disturbance which will release fibers. The presence of asbestos does not constitute a health hazard.

HEALTH ASPECTS:

Do not disturb or cause damage to ACM. Do not sand, grind or abrade materials or cause damage with any type of equipment.

CONDITIONS TO AVOID:

Report any damage, dust or debris that may come from ACM or suspect ACM, or any change in the condition of materials, or accidental disturbance to the Asbestos

Program Manager.

REPORTS OF DAMAGE:

Corrective action initiated to minimize fiber release and protect personnel. RESPONSE ACTION:

ACM will be inspected periodically to evaluate any changes in condition.INSPECTION:

The Camp Lejeune Asbestos Program Manager maintains a copy of the survey for the building.

RECORDKEEPING:

CAMP LEJEUNE Asbestos Program Manager: Phone: (910) 451-5837

BUILT-UP ROOFING ROOF 9/27/1999

GYPSUM BOARD WALLS (WITH

ASSOCIATED JOINT COMPOUND)

100 - 109, 111, 113 - 120, 200 - 205, 207, 209 - 217, 300 - 303, 305, 307 - 317

9/27/1999

PIPE INSULATION 1ST FLOOR MEN'S ROOM 6/21/2000

BUILT-UP ROOFING ROOF 4/26/2007

12" WHITE FLOOR TILE AND ADHESIVE 100, 200, 207, 300, STAIRS 1 - 3 4/26/2007

PIPE INSULATION 1ST FLOOR 4/26/2007

Thursday, August 14, 2025 Page 3 of 5Print Date:

SAMPLES COLLECTED

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

AS214-01-42RI07 4/26/200701 1ST FLOOR,STAIRWELL 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS214-01-43RI07 4/26/200701 1ST FLOOR,STAIRWELL 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS217-01-01 9/27/199901 100 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS217-01-02 9/27/199901 STAIR 2 (FIRST FLOOR) 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS217-01-03 9/27/199901 STAIR 2 (SECOND FLOOR) 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS217-01-40RI07 4/26/200701 2ND FLOOR,HALLWAY 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS217-01-41RI07 4/26/200701 2ND FLOOR,STAIRWELL 0 0 012" WHITE FLOOR TILE

AND ADHESIVE

AS217-01-RI02 11/7/200201 N/A12" WHITE FLOOR TILE

AND ADHESIVE

AS217-02-01 9/27/199902 STAIR 3 (FIRST FLOOR) 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

AS217-02-02 9/27/199902 STAIR 3 (FIRST FLOOR) 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

AS217-02-03 9/27/199902 STAIR 3 (FIRST FLOOR) 0 0 012" BEIGE FLOOR TILE

AND ADHESIVE

AS217-03-01 9/27/199903 STAIR 2 (FIRST FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK

AS217-0301QC 9/27/199903 STAIR 2 (FIRST FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK

AS217-03-02 9/27/199903 STAIR 2 (SECOND FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK

AS217-03-03 9/27/199903 STAIR 3 (SECOND FLOOR) 0 0 0STAIR TREAD/MASTIC BLACK

AS217-04-01 9/27/199904 107 0 0 0BASE COVE/MASTIC, BLACK

AS217-04-02 9/27/199904 200 0 0 0BASE COVE/MASTIC, BLACK

AS217-04-03 9/27/199904 STAIR 1 (THIRD FLOOR) 0 0 0BASE COVE/MASTIC, BLACK

AS217-05-01 9/27/199905 105 0 0 02'x2' CEILING TILE, FISSURED

AS217-0501QC 9/27/199905 105 0 0 02'x2' CEILING TILE, FISSURED

Thursday, August 14, 2025 Page 4 of 5Print Date:

Sample Sample

Date

HA Sample Location Chr

Amo

Oth

Description

AS217-05-02 9/27/199905 200 0 0 02'x2' CEILING TILE, FISSURED

AS217-05-03 9/27/199905 314 0 0 02'x2' CEILING TILE, FISSURED

AS217-06-00RI07 4/26/200706 N/A 9 9 9BUILT-UP ROOFING

AS217-06-RI02 11/7/200206 N/ABUILT-UP ROOFING

AS217-07-01 9/27/199907 100 0 0 0GYPSUM BOARD WALLS

(WITH ASSOCIATED

JOINT COMPOUND)

AS217-07-02 9/27/199907 200 0 0 0GYPSUM BOARD WALLS

(WITH ASSOCIATED

JOINT COMPOUND)

AS217-07-03 9/27/199907 300 0 0 0GYPSUM BOARD WALLS

(WITH ASSOCIATED

JOINT COMPOUND)

AS217-51-40RI07 4/26/200751 MECH ROOM 0 0 0PIPE INSULATION

AS217-60-40 4/26/200760 HALLWAY 0 0 0MISCELLANEOUS

SEALANT

RED,AROUND WIRES

AS217-61-40 4/26/200761 HALLWAY 0 0 0ADHESIVE CEILING TILE HANGER

AS217-62-40 4/26/200762 MECH ROOM 0 0 0PIPE INSULATION

SEALANT

TAN

AS217-63-40 4/26/200763 MECH ROOM 0 0 0PIPE INSULATION

SEALANT

GRAY

AS217-64-40 4/26/200764 MECH ROOM 0 0 0INTERIOR CAULKING, DOOR

274-B-1 2/25/2000B1 BLACK TILE 3RD FLOOR

HALLWAY

5 0 0FLOOR TILE AND

ADHESIVE, UNDER

OTHER

275-B-1 2/25/2000B1 BLACK MASTIC 3RD FLOOR

HALLWAY

3 0 0FLOOR TILE AND

ADHESIVE, UNDER

OTHER

276-B-1 2/25/2000B1 WHITE TILE 3RD FLOOR

HALLWAY

0 0 0FLOOR TILE AND

ADHESIVE, UNDER

OTHER

277-B-1 2/25/2000B1 YELLOW MASTIC 3RD FLOOR

HALLWAY

0 0 0FLOOR TILE AND

ADHESIVE, UNDER

OTHER

Thursday, August 14, 2025 Page 5 of 5Print Date: