About this file

drawing

View the file

Other files

File Type Posted
Camp Crook abstract.xlsx XLSX spreadsheet
Signed PREAWARD Intent to Award.pdf PDF
SF 30 AMEND 7.PDF PDF
C 1.2A.pdf PDF
4-plex basement plumbing.pdf PDF
C 1.1A.pdf PDF
Camp Crook pre bid and QA.2.docx DOCX document
C 9.1A.pdf PDF
Buffalo dump 2.pdf PDF
Buffalo Dump 1.pdf PDF
SF 30 AMEND 6.PDF PDF
Amend 5 SF 30.pdf PDF
SF 30. Amendment 04.pdf PDF
AMEND 3.PDF PDF
SF 30 AMEND 1.PDF PDF
SF 30 AMEND 2.PDF PDF
20.pdf PDF
69.pdf PDF
66.pdf PDF
36.pdf PDF
17.pdf PDF
4.pdf PDF
6.pdf PDF
51.pdf PDF
SF 1442.pdf PDF
14.pdf PDF
21.zip ZIP file
WAGE DETERMINATION.txt TXT text file
38.pdf PDF
78.pdf PDF
1.pdf PDF
63.pdf PDF
28.pdf PDF
12.pdf PDF
10.pdf PDF
37.pdf PDF
64.pdf PDF
11.pdf PDF
73.pdf PDF
23.pdf PDF
72.pdf PDF
47.pdf PDF
50.pdf PDF
67.pdf PDF
41.pdf PDF
5.pdf PDF
30.pdf PDF
68.pdf PDF
13.pdf PDF
54.pdf PDF
Show 40 more

Latest 50 of 99 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KITCHEN

DINING RM.

BEDROOM 1

LIVING RM.

BEDROOM 2

BATH

NEW

BEDROOM

NEW

BEDROOM

MECH.

BATH

LAUND.

HALL

G.F.I.

G.F.I.

G.F.I.

G.F.I.

CFM

W.P.

W.P.

CFM

W.P.

W.P.

200 AMP.

E

NEW

GARAGE

DR OPENER

W .P

NEMA 3R ENCLOSURE.

200A, 240/120V , 1P, MANUAL TRANSFER SWITCH

(MTS)

WITH SOLID NEUTRAL

E2.1D

S O

U T H

R E S

ID

E N

C E M

A

IN

F L O

O R

G A

R A

G E E

L E C

T R

IC

A L P

L A

N S

1/4" = 1'-0"

A2.1A : A2.1A

SOUTH RESIDENCE MAIN FLOOR ELECTRICAL PLAN

C A

M P C

R O

O K

C U

S T E R N

A T

IO

N A

L F

O R

E S T

C A

M P C

R O

O K

S D

2 2 2 N O R T H H I G G I N S

FAX 4 0 6 . 7 2 1 . 1 8 8 7

PH 4 0 6 . 7 2 1 . 5 6 4 3

M I S S O U L A, M T 59802 www.aearchitects.com

B I L L I N G S, M T 59101

FAX 4 0 6 . 2 4 8 . 2 4 2 7

PH 4 0 6 . 2 4 8 . 2 6 3 3

6 0 8 N O R T H 2 9 T H

A R C H I T E C T U R E

O W N E R

H I S T O R I C

I N T E R I O R S

ARCHITECTS PC

ISSUE DATE

REVISIONS

P R O J E C T

D R A W

IN

G

PROJECT No 09051

U S D

A F

O R E S T

S E R

V

IC

E

R E G

IO

N

12.16.09

R

E G I S T E R E D P

RO

F ESS IONA

L A R C H I T E C

T

S O

UTH DA K

O

T A

RE

G . NO .

JAMES R. McDONALD

NORTH SOUTH RESIDENCE GARAGE ELECTRICAL PLAN

A2.1D : A2.1D 1/4" = 1'-0"

NORTH19

MOUNT NEW W.P. OUTLET

BELOW SOFFIT

LOCATION OF REVERSE SERVICE

RECEPTACLE. COORDINATE WITH

CONTRACTING OFFICER

MOUNT NEW W.P. OUTLET

BELOW SOFFIT

E2.1B : A2.1B

N.T.S.

TYP. RESIDENTIAL ONE-LINE DIAGRAM

W D

TO HOUSE

SPECIAL EQUIPMENT OUTLET

OUTLET (G.F.I.)

OUTLET (220V)

SWITCHED OUTLET

150 CFM FAN (RECESSED)

4 WAY SWITCH

(CEILING)

SURFACE MOUNTED FIXTURE

CEILING FAN

(WALL)

SMOKE DETECTOR (110V)

DUPLEX OUTLET (110V)

SURFACE MOUNTED FIXTURE

WATERPROOF OUTLET

WP

SWITCH

3 WAY SWITCH

RECESSED LIGHT FIXTURE

GFI

ELECTRICAL LEGEND

COAX JACK

TELEPHONE OUTLET

FLOOD LIGHT

FAN SWITCH

F

(CEILING)

EXISTING SURFACE MOUNTED FIXTURE

E

200 AMP

NEW 200 AMP ELECTRICAL PANEL

1. CONTRACTOR SHALL VERIFY ALL EXISTING LIGHT LOCATIONS AND SWITCHING. REUSE ALL LOCATIONS WHERE POSSIBLE.

2. CONTRACTOR SHALL PROVIDE NEW SWITCH AT ATTIC ACCESS DOORS AND A MINIMUM OF (4) KEYLESS SOCKETS IN CRAWL SPACE.

3. EXISTING GARAGE SHALL BE RE-CONNECTED BACK TO THE 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN. CONTRACTOR

SHALL COORDINATE CONNECTIONS WITH NEW AND EXISTING UTILITY SERVICES.

4. CONTRACTOR SHALL VERIFY ALL EXISTING LIGHT SWITCHING AND OUTLET LOCATIONS IN EXISTING WALLS AND CEILINGS. REUSE

LOCATIONS IF POSSIBLE.

5. EXISTING GARAGE SHALL BE CONNECTED BACK TO NEW 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN.

6. WORK AT CRAWL SPACE: PROVIDE A NEW LIGHT FIXTURE NEAR EACH ACCESS HATCH (3-WAY SWITCH ON SAME CIRCUIT). PROVIDE (1)

OUTLET NEAR HATCH AT PANTRY. COORDINATE ANY ADDITIONAL ELECTRICAL REQUIREMENTS FOR NEW ON-DEMAND WATER HEATER

OR OTHER NEW WORK.

7. CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE ELECTRICAL SYSTEM IN RESIDENCE. INSURE THAT NEW AND EXISTING TO

REMAINING ELECTRICAL SYSTEMS MEET THE CURRENT NFPA 70 NATIONAL ELECTRICAL CODE.

8. ROUTE EXISTING ELECTRICAL CIRCUITS TO NEW JUNCTION BOX LOCATED NEAR EXISTING ELECTRICAL PANEL AND FEED TO NEW 200

AMP PANEL.

GENERAL ELECTRICAL NOTES

ELECTRICAL KEYNOTES#

CONTRACTOR TO PROVIDE NEW CEILING MOUNTED OUTLET. COORDINATE WITH O.H. DOOR CONTROLLER.

CONTRACTOR TO PROVIDE EXTERIOR LIGHT W/ PHOTO CELL & TIMER.

CONTRACTOR TO PROVIDE PRESET SWITCH TIMER TO FAN/ LIGHT FIXTURE. 'LEVITON 612-6260-00W 'DECORA' 60-30-20-10 OR

EQUAL.

APPROXIMATE LOCATION OF NEW SEWER LINE CONNECTION. CONTRACTOR SHALL COORDINATE LOCATION AND CONNECTION

WITH ALL NEW AND EXISTING SANITARY SEWER LINES AND DRAIN LINES.

EXISTING CEILING FAN

E

E2.1D.dwg
E2.1B

File details come from the government source that posted it. Updated .