76.pdf
PDF 240 KB Posted
- Solicitation number
- AG-82B1-S-10-0081
About this file
drawing
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Camp Crook abstract.xlsx | XLSX spreadsheet | |
| Signed PREAWARD Intent to Award.pdf | ||
| SF 30 AMEND 7.PDF | ||
| C 1.2A.pdf | ||
| 4-plex basement plumbing.pdf | ||
| C 1.1A.pdf | ||
| Camp Crook pre bid and QA.2.docx | DOCX document | |
| C 9.1A.pdf | ||
| Buffalo dump 2.pdf | ||
| Buffalo Dump 1.pdf | ||
| SF 30 AMEND 6.PDF | ||
| Amend 5 SF 30.pdf | ||
| SF 30. Amendment 04.pdf | ||
| AMEND 3.PDF | ||
| SF 30 AMEND 1.PDF | ||
| SF 30 AMEND 2.PDF | ||
| 20.pdf | ||
| 69.pdf | ||
| 66.pdf | ||
| 36.pdf | ||
| 17.pdf | ||
| 4.pdf | ||
| 6.pdf | ||
| 51.pdf | ||
| SF 1442.pdf | ||
| 14.pdf | ||
| 21.zip | ZIP file | |
| WAGE DETERMINATION.txt | TXT text file | |
| 38.pdf | ||
| 78.pdf | ||
| 1.pdf | ||
| 63.pdf | ||
| 28.pdf | ||
| 12.pdf | ||
| 10.pdf | ||
| 37.pdf | ||
| 64.pdf | ||
| 11.pdf | ||
| 73.pdf | ||
| 23.pdf | ||
| 72.pdf | ||
| 47.pdf | ||
| 50.pdf | ||
| 67.pdf | ||
| 41.pdf | ||
| 5.pdf | ||
| 30.pdf | ||
| 68.pdf | ||
| 13.pdf | ||
| 54.pdf |
Show 40 more
Latest 50 of 99 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
KITCHEN
DINING RM.
BEDROOM 1
LIVING RM.
BEDROOM 2
BATH
NEW
BEDROOM
NEW
BEDROOM
MECH.
BATH
LAUND.
HALL
G.F.I.
G.F.I.
G.F.I.
G.F.I.
CFM
W.P.
W.P.
CFM
W.P.
W.P.
200 AMP.
E
NEW
GARAGE
DR OPENER
W .P
NEMA 3R ENCLOSURE.
200A, 240/120V , 1P, MANUAL TRANSFER SWITCH
(MTS)
WITH SOLID NEUTRAL
E2.1D
S O
U T H
R E S
ID
E N
C E M
A
IN
F L O
O R
G A
R A
G E E
L E C
T R
IC
A L P
L A
N S
1/4" = 1'-0"
A2.1A : A2.1A
SOUTH RESIDENCE MAIN FLOOR ELECTRICAL PLAN
C A
M P C
R O
O K
C U
S T E R N
A T
IO
N A
L F
O R
E S T
C A
M P C
R O
O K
S D
2 2 2 N O R T H H I G G I N S
FAX 4 0 6 . 7 2 1 . 1 8 8 7
PH 4 0 6 . 7 2 1 . 5 6 4 3
M I S S O U L A, M T 59802 www.aearchitects.com
B I L L I N G S, M T 59101
FAX 4 0 6 . 2 4 8 . 2 4 2 7
PH 4 0 6 . 2 4 8 . 2 6 3 3
6 0 8 N O R T H 2 9 T H
A R C H I T E C T U R E
O W N E R
H I S T O R I C
I N T E R I O R S
ARCHITECTS PC
ISSUE DATE
REVISIONS
P R O J E C T
D R A W
IN
G
PROJECT No 09051
U S D
A F
O R E S T
S E R
V
IC
E
R E G
IO
N
12.16.09
R
E G I S T E R E D P
RO
F ESS IONA
L A R C H I T E C
T
S O
UTH DA K
O
T A
RE
G . NO .
JAMES R. McDONALD
NORTH SOUTH RESIDENCE GARAGE ELECTRICAL PLAN
A2.1D : A2.1D 1/4" = 1'-0"
NORTH19
MOUNT NEW W.P. OUTLET
BELOW SOFFIT
LOCATION OF REVERSE SERVICE
RECEPTACLE. COORDINATE WITH
CONTRACTING OFFICER
MOUNT NEW W.P. OUTLET
BELOW SOFFIT
E2.1B : A2.1B
N.T.S.
TYP. RESIDENTIAL ONE-LINE DIAGRAM
W D
TO HOUSE
SPECIAL EQUIPMENT OUTLET
OUTLET (G.F.I.)
OUTLET (220V)
SWITCHED OUTLET
150 CFM FAN (RECESSED)
4 WAY SWITCH
(CEILING)
SURFACE MOUNTED FIXTURE
CEILING FAN
(WALL)
SMOKE DETECTOR (110V)
DUPLEX OUTLET (110V)
SURFACE MOUNTED FIXTURE
WATERPROOF OUTLET
WP
SWITCH
3 WAY SWITCH
RECESSED LIGHT FIXTURE
GFI
ELECTRICAL LEGEND
COAX JACK
TELEPHONE OUTLET
FLOOD LIGHT
FAN SWITCH
F
(CEILING)
EXISTING SURFACE MOUNTED FIXTURE
E
200 AMP
NEW 200 AMP ELECTRICAL PANEL
1. CONTRACTOR SHALL VERIFY ALL EXISTING LIGHT LOCATIONS AND SWITCHING. REUSE ALL LOCATIONS WHERE POSSIBLE.
2. CONTRACTOR SHALL PROVIDE NEW SWITCH AT ATTIC ACCESS DOORS AND A MINIMUM OF (4) KEYLESS SOCKETS IN CRAWL SPACE.
3. EXISTING GARAGE SHALL BE RE-CONNECTED BACK TO THE 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN. CONTRACTOR
SHALL COORDINATE CONNECTIONS WITH NEW AND EXISTING UTILITY SERVICES.
4. CONTRACTOR SHALL VERIFY ALL EXISTING LIGHT SWITCHING AND OUTLET LOCATIONS IN EXISTING WALLS AND CEILINGS. REUSE
LOCATIONS IF POSSIBLE.
5. EXISTING GARAGE SHALL BE CONNECTED BACK TO NEW 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN.
6. WORK AT CRAWL SPACE: PROVIDE A NEW LIGHT FIXTURE NEAR EACH ACCESS HATCH (3-WAY SWITCH ON SAME CIRCUIT). PROVIDE (1)
OUTLET NEAR HATCH AT PANTRY. COORDINATE ANY ADDITIONAL ELECTRICAL REQUIREMENTS FOR NEW ON-DEMAND WATER HEATER
OR OTHER NEW WORK.
7. CONTRACTOR IS RESPONSIBLE FOR PROVIDING A COMPLETE ELECTRICAL SYSTEM IN RESIDENCE. INSURE THAT NEW AND EXISTING TO
REMAINING ELECTRICAL SYSTEMS MEET THE CURRENT NFPA 70 NATIONAL ELECTRICAL CODE.
8. ROUTE EXISTING ELECTRICAL CIRCUITS TO NEW JUNCTION BOX LOCATED NEAR EXISTING ELECTRICAL PANEL AND FEED TO NEW 200
AMP PANEL.
GENERAL ELECTRICAL NOTES
ELECTRICAL KEYNOTES#
CONTRACTOR TO PROVIDE NEW CEILING MOUNTED OUTLET. COORDINATE WITH O.H. DOOR CONTROLLER.
CONTRACTOR TO PROVIDE EXTERIOR LIGHT W/ PHOTO CELL & TIMER.
CONTRACTOR TO PROVIDE PRESET SWITCH TIMER TO FAN/ LIGHT FIXTURE. 'LEVITON 612-6260-00W 'DECORA' 60-30-20-10 OR
EQUAL.
APPROXIMATE LOCATION OF NEW SEWER LINE CONNECTION. CONTRACTOR SHALL COORDINATE LOCATION AND CONNECTION
WITH ALL NEW AND EXISTING SANITARY SEWER LINES AND DRAIN LINES.
EXISTING CEILING FAN
E
| E2.1D.dwg |
| E2.1B |
File details come from the government source that posted it. Updated .