About this file

drawing

View the file

Other files

File Type Posted
Camp Crook abstract.xlsx XLSX spreadsheet
Signed PREAWARD Intent to Award.pdf PDF
SF 30 AMEND 7.PDF PDF
C 1.2A.pdf PDF
4-plex basement plumbing.pdf PDF
C 1.1A.pdf PDF
Camp Crook pre bid and QA.2.docx DOCX document
C 9.1A.pdf PDF
Buffalo dump 2.pdf PDF
Buffalo Dump 1.pdf PDF
SF 30 AMEND 6.PDF PDF
Amend 5 SF 30.pdf PDF
SF 30. Amendment 04.pdf PDF
AMEND 3.PDF PDF
SF 30 AMEND 1.PDF PDF
SF 30 AMEND 2.PDF PDF
20.pdf PDF
69.pdf PDF
66.pdf PDF
36.pdf PDF
4.pdf PDF
6.pdf PDF
51.pdf PDF
SF 1442.pdf PDF
14.pdf PDF
21.zip ZIP file
WAGE DETERMINATION.txt TXT text file
38.pdf PDF
78.pdf PDF
1.pdf PDF
63.pdf PDF
28.pdf PDF
12.pdf PDF
10.pdf PDF
37.pdf PDF
64.pdf PDF
11.pdf PDF
73.pdf PDF
23.pdf PDF
72.pdf PDF
47.pdf PDF
50.pdf PDF
67.pdf PDF
41.pdf PDF
5.pdf PDF
30.pdf PDF
68.pdf PDF
13.pdf PDF
76.pdf PDF
54.pdf PDF
Show 40 more

Latest 50 of 99 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

R O

O F P

L A

N

A2.2A

C A

M P C

R O

O K

C U

S T E R N

A T

IO

N A

L F

O R

E S T

C A

M P C

R O

O K

S D

2 2 2 N O R T H H I G G I N S

FAX 4 0 6 . 7 2 1 . 1 8 8 7

PH 4 0 6 . 7 2 1 . 5 6 4 3

M I S S O U L A, M T 59802 www.aearchitects.com

B I L L I N G S, M T 59101

FAX 4 0 6 . 2 4 8 . 2 4 2 7

PH 4 0 6 . 2 4 8 . 2 6 3 3

6 0 8 N O R T H 2 9 T H

A R C H I T E C T U R E

O W N E R

H I S T O R I C

I N T E R I O R S

ARCHITECTS PC

ISSUE DATE

REVISIONS

P R O J E C T

D R A W

IN

G

PROJECT No 09051

U S D

A F

O R E S T

S E R

V

IC

E

R E G

IO

N

12.16.09

16 ROOF PLAN

A2.2A : A2.2A 3/16" = 1'-0"

NORTH

/2

A S R E Q 'D

PIPE PENETRATION1

N.T.S.

PROVIDE STORMITE LEAD

FLASHING NO. S1100-4 W/

6" SKIRT (PROVIDE LEAD

FLASHINGS ON ALL THRU

ROOF PENETRATIONS)

CONDUIT OR PIPE AS

OCCURS 8" SKIRT

(3) VANDAL PROOF SET

SCREWS (TYP.)

PERMASEAL

ROOF MASTIC (TYP.) CONT.

STL. REINFORCING

A2.2A : A2.2A

FOR R.D. & O.D. PIPING

AND INSULATION

SEE PLUMBING DWG'S

A2.2A : A2.2A

2 TYP. ROOF DRAIN DETAIL

3/4" = 1'-0"

CAST-IRON ROOF DRAIN &

OVERFLOW DRAIN W/

UNDERDECK CLAMP, ROOF SUMP

RECEIVER & PIPING - SEE PLMG.

DWGS FOR PIPING MAT'L & LAYOUT

SINGLE-PLY ROOF SYSTEM

D.S.

= CONT. ALUM. GUTTER W/ PRE-FINSIHED STANDARD KYNAR '500'

1/4"/FT. (MIN.) DRAINAGE SLOPE TO DOWNSPOUT LOCATION

= DOWNSPOUT LOCATION W/ PRE-FINISHED STANDARD '500' KYNAR COLOR:

TO MATCH ADJACENT WALL FINISHES W/ CONNECTION TO UNDERGROUND

DRAINAGE PIPING - COLLECT ALL ROOF DRAINS AND PIPE TO SUPPLEMENTAL

PIPING (DAYLIGHTING) PER CIVIL & PLUMBING DRAWINGS. ALL DOWN

SPOUTS TO BE SQUARE.

GUTTER

ROOF PLAN LEGEND

NOTE:

FLAT ROOF AREA SHALL SLOPE

1/4" / 1'-0" SLOPE MINIMUM W/

TAPERED INSULATION CRICKETS

GUTTERS

PRE-FINSIHED STANDARD KYNAR '500' COLOR: TO MATCH EAVES. ALL GUTTERS TO

HAVE 'GUTTER SCREEN' TO MINIMIZE CLOGGING

R.D.

TAPERED INSULATION

CRICKET, TYPICAL

D.S.

LINE OF ROOF TRANSITION

R.D.

TAPERED INSULATION

CRICKET, TYPICAL

LINE OF CANOPY BELOW

LINE OF AWNING BELOW

GUTTER

/2 " : 1

'-0

LINE OF ROOF TRANSITION

PARAPET WALL OPEN BELOW

D.S.

SINGLE-PLY MEMBRANE

SINGLE-PLY MEMBRANE

METAL PANEL ROOF METAL PANEL ROOF

CANOPY BELOW

GUTTER

1/4" SLOPE

/4 S L O P E

1/4" SLOPE

/2 " : 1

'-0

/2 " : 1

'-0

/2 " : 1

'-0

2'-0"

O.D.

O.D.

A2.2A

A2.2A

SEE 17/A5.3, SIM.

@ CANOPY

SINGLE PLY ROOFING CONTINUES

TO LINE OF PARAPET LAPPED UNDER

METAL PANEL ROOF ASSEMBLY

SINGLE PLY ROOFING CONTINUES

TO LINE OF PARAPET LAPPED UNDER

METAL PANEL ROOF ASSEMBLY

ROOFING MFR. TO PROVIDE

ENGINEERED SNOW STOP AT

METAL ROOF

SNOW STOP

SNOW STOP

VTR

VTR

VTR

VTR

VTR

SINGLE-PLY MEMBRANE OVER

TAPERED INSULATION

D.S. BELOW AT CANOPY

TAPERED INSULATION

CRICKET, TYPICAL

09051 A2.2A.dwg
A2.2A