17.pdf
PDF 153 KB Posted
- Solicitation number
- AG-82B1-S-10-0081
About this file
drawing
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Camp Crook abstract.xlsx | XLSX spreadsheet | |
| Signed PREAWARD Intent to Award.pdf | ||
| SF 30 AMEND 7.PDF | ||
| C 1.2A.pdf | ||
| 4-plex basement plumbing.pdf | ||
| C 1.1A.pdf | ||
| Camp Crook pre bid and QA.2.docx | DOCX document | |
| C 9.1A.pdf | ||
| Buffalo dump 2.pdf | ||
| Buffalo Dump 1.pdf | ||
| SF 30 AMEND 6.PDF | ||
| Amend 5 SF 30.pdf | ||
| SF 30. Amendment 04.pdf | ||
| AMEND 3.PDF | ||
| SF 30 AMEND 1.PDF | ||
| SF 30 AMEND 2.PDF | ||
| 20.pdf | ||
| 69.pdf | ||
| 66.pdf | ||
| 36.pdf | ||
| 4.pdf | ||
| 6.pdf | ||
| 51.pdf | ||
| SF 1442.pdf | ||
| 14.pdf | ||
| 21.zip | ZIP file | |
| WAGE DETERMINATION.txt | TXT text file | |
| 38.pdf | ||
| 78.pdf | ||
| 1.pdf | ||
| 63.pdf | ||
| 28.pdf | ||
| 12.pdf | ||
| 10.pdf | ||
| 37.pdf | ||
| 64.pdf | ||
| 11.pdf | ||
| 73.pdf | ||
| 23.pdf | ||
| 72.pdf | ||
| 47.pdf | ||
| 50.pdf | ||
| 67.pdf | ||
| 41.pdf | ||
| 5.pdf | ||
| 30.pdf | ||
| 68.pdf | ||
| 13.pdf | ||
| 76.pdf | ||
| 54.pdf |
Show 40 more
Latest 50 of 99 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
R O
O F P
L A
N
A2.2A
C A
M P C
R O
O K
C U
S T E R N
A T
IO
N A
L F
O R
E S T
C A
M P C
R O
O K
S D
2 2 2 N O R T H H I G G I N S
FAX 4 0 6 . 7 2 1 . 1 8 8 7
PH 4 0 6 . 7 2 1 . 5 6 4 3
M I S S O U L A, M T 59802 www.aearchitects.com
B I L L I N G S, M T 59101
FAX 4 0 6 . 2 4 8 . 2 4 2 7
PH 4 0 6 . 2 4 8 . 2 6 3 3
6 0 8 N O R T H 2 9 T H
A R C H I T E C T U R E
O W N E R
H I S T O R I C
I N T E R I O R S
ARCHITECTS PC
ISSUE DATE
REVISIONS
P R O J E C T
D R A W
IN
G
PROJECT No 09051
U S D
A F
O R E S T
S E R
V
IC
E
R E G
IO
N
12.16.09
16 ROOF PLAN
A2.2A : A2.2A 3/16" = 1'-0"
NORTH
/2
A S R E Q 'D
PIPE PENETRATION1
N.T.S.
PROVIDE STORMITE LEAD
FLASHING NO. S1100-4 W/
6" SKIRT (PROVIDE LEAD
FLASHINGS ON ALL THRU
ROOF PENETRATIONS)
CONDUIT OR PIPE AS
OCCURS 8" SKIRT
(3) VANDAL PROOF SET
SCREWS (TYP.)
PERMASEAL
ROOF MASTIC (TYP.) CONT.
STL. REINFORCING
A2.2A : A2.2A
FOR R.D. & O.D. PIPING
AND INSULATION
SEE PLUMBING DWG'S
A2.2A : A2.2A
2 TYP. ROOF DRAIN DETAIL
3/4" = 1'-0"
CAST-IRON ROOF DRAIN &
OVERFLOW DRAIN W/
UNDERDECK CLAMP, ROOF SUMP
RECEIVER & PIPING - SEE PLMG.
DWGS FOR PIPING MAT'L & LAYOUT
SINGLE-PLY ROOF SYSTEM
D.S.
= CONT. ALUM. GUTTER W/ PRE-FINSIHED STANDARD KYNAR '500'
1/4"/FT. (MIN.) DRAINAGE SLOPE TO DOWNSPOUT LOCATION
= DOWNSPOUT LOCATION W/ PRE-FINISHED STANDARD '500' KYNAR COLOR:
TO MATCH ADJACENT WALL FINISHES W/ CONNECTION TO UNDERGROUND
DRAINAGE PIPING - COLLECT ALL ROOF DRAINS AND PIPE TO SUPPLEMENTAL
PIPING (DAYLIGHTING) PER CIVIL & PLUMBING DRAWINGS. ALL DOWN
SPOUTS TO BE SQUARE.
GUTTER
ROOF PLAN LEGEND
NOTE:
FLAT ROOF AREA SHALL SLOPE
1/4" / 1'-0" SLOPE MINIMUM W/
TAPERED INSULATION CRICKETS
GUTTERS
PRE-FINSIHED STANDARD KYNAR '500' COLOR: TO MATCH EAVES. ALL GUTTERS TO
HAVE 'GUTTER SCREEN' TO MINIMIZE CLOGGING
R.D.
TAPERED INSULATION
CRICKET, TYPICAL
D.S.
LINE OF ROOF TRANSITION
R.D.
TAPERED INSULATION
CRICKET, TYPICAL
LINE OF CANOPY BELOW
LINE OF AWNING BELOW
GUTTER
/2 " : 1
'-0
LINE OF ROOF TRANSITION
PARAPET WALL OPEN BELOW
D.S.
SINGLE-PLY MEMBRANE
SINGLE-PLY MEMBRANE
METAL PANEL ROOF METAL PANEL ROOF
CANOPY BELOW
GUTTER
1/4" SLOPE
/4 S L O P E
1/4" SLOPE
/2 " : 1
'-0
/2 " : 1
'-0
/2 " : 1
'-0
2'-0"
O.D.
O.D.
A2.2A
A2.2A
SEE 17/A5.3, SIM.
@ CANOPY
SINGLE PLY ROOFING CONTINUES
TO LINE OF PARAPET LAPPED UNDER
METAL PANEL ROOF ASSEMBLY
SINGLE PLY ROOFING CONTINUES
TO LINE OF PARAPET LAPPED UNDER
METAL PANEL ROOF ASSEMBLY
ROOFING MFR. TO PROVIDE
ENGINEERED SNOW STOP AT
METAL ROOF
SNOW STOP
SNOW STOP
VTR
VTR
VTR
VTR
VTR
SINGLE-PLY MEMBRANE OVER
TAPERED INSULATION
D.S. BELOW AT CANOPY
TAPERED INSULATION
CRICKET, TYPICAL