About this file

drawing

View the file

Other files

File Type Posted
Camp Crook abstract.xlsx XLSX spreadsheet
Signed PREAWARD Intent to Award.pdf PDF
SF 30 AMEND 7.PDF PDF
C 1.2A.pdf PDF
4-plex basement plumbing.pdf PDF
C 1.1A.pdf PDF
Camp Crook pre bid and QA.2.docx DOCX document
C 9.1A.pdf PDF
Buffalo dump 2.pdf PDF
Buffalo Dump 1.pdf PDF
SF 30 AMEND 6.PDF PDF
Amend 5 SF 30.pdf PDF
SF 30. Amendment 04.pdf PDF
AMEND 3.PDF PDF
SF 30 AMEND 1.PDF PDF
SF 30 AMEND 2.PDF PDF
20.pdf PDF
69.pdf PDF
36.pdf PDF
17.pdf PDF
4.pdf PDF
6.pdf PDF
51.pdf PDF
SF 1442.pdf PDF
14.pdf PDF
21.zip ZIP file
WAGE DETERMINATION.txt TXT text file
38.pdf PDF
78.pdf PDF
1.pdf PDF
63.pdf PDF
28.pdf PDF
12.pdf PDF
10.pdf PDF
37.pdf PDF
64.pdf PDF
11.pdf PDF
73.pdf PDF
23.pdf PDF
72.pdf PDF
47.pdf PDF
50.pdf PDF
67.pdf PDF
41.pdf PDF
5.pdf PDF
30.pdf PDF
68.pdf PDF
13.pdf PDF
76.pdf PDF
54.pdf PDF
Show 40 more

Latest 50 of 99 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

MIDDLE RES.

GARAGE

LIVING ROOM

KITCHEN

HALL

BEDROOM

BEDROOM

BEDROOM

RAMP

HALF BATH &

LAUNDRY

OFFICE

ENTRY

BATHROOM

DISCONNECT AND REMOVE

EXISTING FEEDER

M

(3) #3/0 CU THWN AND (1) #4 CU GND IN 1-1/2" C.

(3) #3/0 CU THWN AND (1) #4 CU GND IN 1-1/2" C.

KITCHEN

E2.1C

M

ID

D L E R

E S

ID

E N

C E P

O W

E R

L

IG

H T

IN

G P

L A

N

1/4" = 1'-0"E2.1C : E2.1C

16 MIDDLE RESIDENCE GARAGE PLAN

C A

M P C

R O

O K

C U

S T E R N

A T

IO

N A

L F

O R

E S T

C A

M P C

R O

O K

S D

2 2 2 N O R T H H I G G I N S

FAX 4 0 6 . 7 2 1 . 1 8 8 7

PH 4 0 6 . 7 2 1 . 5 6 4 3

M I S S O U L A, M T 59802 www.aearchitects.com

B I L L I N G S, M T 59101

FAX 4 0 6 . 2 4 8 . 2 4 2 7

PH 4 0 6 . 2 4 8 . 2 6 3 3

6 0 8 N O R T H 2 9 T H

A R C H I T E C T U R E

O W N E R

H I S T O R I C

I N T E R I O R S

ARCHITECTS PC

ISSUE DATE

REVISIONS

P R O J E C T

D R A W

IN

G

PROJECT No 09051

U S D

A F

O R E S T

S E R

V

IC

E

R E G

IO

N

12.16.09

R

E G I S T E R E D P

RO

F ESS IONA

L A R C H I T E C

T

S O

UTH DA K

O

T A

RE

G . NO .

JAMES R. McDONALD

ELECTRICAL KEYNOTES#

1/4" = 1'-0"

12 MIDDLE RESIDENCE MAIN FLOOR PLAN

NORTH

NORTH

PROVIDE EXTERIOR LIGHT WITH PHOTOCELL & TIMER1

E2.1C : E2.1C

ELECTRICAL LEGEND

1. EVERY ATTEMPT HAS BEEN MADE TO ASSURE THE ACCURACY OF THE DRAWINGS THROUGH EXISTING AS-BUILT DATA AND

FIELD VERIFICATION. CONTRACTOR RESPONSIBLE TO VERIFY EXISTING CONDITIONS BEFORE CONSTRUCTION / ORDERING /

INSTALLATION & NOTIFY THE CONTRACTING OFFICER IMMEDIATELY IF ANY DISCREPANCY EXISTS FOR WRITTEN

CLARIFICATION.

2. DRAWINGS CONTAINED WITHIN THESE DOCUMENTS ARE ABBREVIATED IN NATURE. CONTRACTOR IS EXPECTED TO USE

QUALITY, ACCEPTABLE STANDARD CONSTRUCTION PRACTICES & TECHNIQUES.

3. ALL CONSTRUCTION SHALL CONFORM TO ALL APPLICABLE STANDARDS & REGULATIONS AS PRESCRIBED BY THE 2009

INTERNATIONAL RESIDENTIAL BUILDING CODE, ALL APPLICABLE PLUMBING CODES, ALL APPLICABLE MECHANICAL CODES, ALL

APPLICABLE ELECTRICAL CODES, AND APPLICABLE ACCESSIBILITY CODES.

4. MECHANICAL / PLUMBING / ELECTRICAL SHALL BE COORDINATED AND INSTALLED BY CONTRACTOR TO BE CONSISTENT WITH

THE INTENT OF THE DRAWINGS AND SHALL BE IN ACCORDANCE WITH ALL APPLICABLE CODES.

5. CONTRACTOR RESPONSIBLE FOR DOCUMENTATION OF ACCURATE AS-BUILTS INFORMATION / DRAWINGS AT THE

CONCLUSION OF THE PROJECT FOR SUBMITTAL TO THE CONTRACTING OFFICER.

6. CONTRACTOR TO MAINTAIN INTEGRITY OF EXISTING BUILDING / SYSTEMS AT ALL TIMES. NOTIFY CONTRACTING OFFICER

BEFORE COMPROMISING ANY SYSTEM DUE TO THE NEW CONSTRUCTION. SOME DEMOLITION / CONSTRUCTION MAY BE

REQUIRED TO BE PERFORMED AFTER BUSINESS HOURS - COORDINATE W/ CONTRACTING OFFICER.

7. DO NOT SCALE FROM DRAWINGS. IF A DIMENSION DOES NOT EXIST OR IS IN ERROR, CONTACT THE CONTRACTING OFFICER

IMMEDIATELY FOR WRITTEN CLARIFICATION.

8. CONTRACTOR(S) SHALL GUARANTEE THEIR WORK FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE SUBSTANTIAL

COMPLETION. CONTRACTOR(S) SHALL REPLACE ALL DEFECTIVE PARTS & SUPPLIES AT THEIR COST.

9. CONTRACTOR SHALL RECOGNIZE THE REMODEL ON THESE STRUCTURES MAY BE PHASED IN ORDER TO ACCOMMODATE

EXISTING TENANTS. CONTRACTOR SHALL COORDINATE ALL WORK ACTIVITIES WITH CONTRACTING OFFICER AND DISTRICT

RANGER.

10. CONTRACTOR SHALL PROVIDE ALL SHORING AS NEEDED DURING THE CONSTRUCTION PROCESS.

11. CONTRACTOR SHALL BE AWARE THAT LEAD PAINT CONTAINING MATERIALS AND VERMICULITE IS PRESENT IN THE

CONSTRUCTION AREA. CONTRACTOR IS RESPONSIBLE FOR IDENTIFYING AND TAKING THE NECESSARY PRECAUTIONS TO SAFELY

CONDUCT THE WORK INDICATED.

12. CONTRACTOR SHALL SUPPLY ALL PARTS, MATERIALS & LABOR ASSOCIATED WITH COMPLETING THIS PROJECT, UNLESS

OTHERWISE NOTED.

13. CONTRACTOR SHALL BE RESPONSIBLE TO LOCATE ALL EXISTING UTILITIES.

14. CONTRACTOR TO REFER TO ALL STRUCTURAL NOTES WITHIN DOCUMENTS

GENERAL PROJECT NOTES

1 1

PROVIDE SWITCHED PRESET TIMER TO FAN/LIGHT FIXTURE. LEVITON

612-6260-00W DECORA 60-30-20-10 OR EQUAL

OUTLET BELOW COUNTERTOP LEVEL

1 SUPPLEMENTAL KITCHEN ELECTRICAL

E2.1C : E2.1C 1/4" = 1'-0"

SEE DETAIL 1 THIS SHEET FOR SUPPLEMENTAL KITCHEN ELECTRICAL.

4 44

5 CEILING MOUNT OUTLET

PROVIDE AUTOMATIC GARAGE DOOR OPENER. WIRED CONTROLLER TO BE MOUNTED NEAR ELECTRICAL

SWITCHES NORTH OF GARAGE MAN DOOR AND TO BE MAXIMUM 48" ABOVE FINISH FLOOR.

1. EXISTING GARAGE SHALL BE RE-CONNECTED BACK TO THE 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN.

COORDINATE TRENCHING WITH NEW & EXISTING UTILITIES & SERVICES.

2. CONTRACTOR SHALL VERIFY EXISTING LIGHT

3. ALL NEW ELECTRICAL CONTROLS AND OUTLETS SHALL BE MOUNTED A MAXIMUM OF 48" AFF IF UNOBSTRUCTED. IF NEW

CONTROL OR NEW OUTLET IS OBSTRUCTED BY 24" COUNTERTOP OR OTHER SIMILAR BUILT ELEMENT, THEN CONTROLS AND

OUTLETS SHALL BE MOUNTED A MAXIMUM OF 46" AFF. NEW ELECTRICAL OUTLETS SHALL BE MOUNTED A MINIMUM 15" AFF.

WHERE REASONABLY POSSIBLE, PROVIDE ACCESS TO NEW OUTLETS AND NEW SWITCHES NEAR APPLIANCES.

4. CONTRACTOR SHALL VERIFY EXISTING LIGHTS, SWITCHES, AND OUTLET LOCATIONS IN EXISTING WALLS & CEILINGS.

RE-USE LOCATIONS IF POSSIBLE AND IN PROPER WORKING ORDER.

5. LIVING ROOM SHALL HAVE (1) COAX RECEPTACLE MINIMUM. PROVIDE NEW IF REQUIRED.

6. WORK AT CRAWL SPACE: PROVIDE A NEW LIGHT FIXTURE AND SWITCH NEAR EACH CRAWLSPACE ACCESS HATCH. IF BOTH

CRAWL SPACES ZONES HAVE AN ACCESSIBLE LINE OF SITE, PROVIDE 3-WAY SWITCHING ON SAME CIRCUIT. PROVIDE (1)

OUTLET NEAR HATCH AT PANTRY. COORDINATE ANY ADDITIONAL ELECTRICAL REQUIREMENTS FOR NEW ON-DEMAND WATER

HEATER OR OTHER NEW WORK.

ELECTRICAL NOTES

7 LOCATION OF REVERSE SERVICE RECEPTACLE. COORDINATE FINAL LOCATION WITH CONTRACTING OFFICER.

PROVIDE NEW LIGHT FIXTURE AND SWITCH IN ATTIC SPACE. LOCATE SWITCH NEAR ACCESS PANEL.

1. CONTRACTOR SHALL VERIFY ALL EXISTING LIGHT LOCATIONS AND SWITCHING. REUSE ALL LOCATIONS WHERE POSSIBLE.

2. CONTRACTOR SHALL PROVIDE NEW SWITCH AT ATTIC ACCESS DOORS AND A MINIMUM OF (4) KEYLESS SOCKETS IN CRAWL-

SPACE.

3. EXISTING GARAGE SHALL BE RE-CONNECTED BACK TO THE 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN.

CONTRACTOR SHALL COORDINATE CONNECTIONS WITH NEW AND EXISTING UTILITY SERVICES.

4. CONTRACTOR SHALL VERIFY ALL EXISTING LIGHT SWITCHING AND OUTLET LOCATIONS IN EXISTING WALLS AND CEILINGS.

REUSE LOCATIONS IF POSSIBLE.

5. EXISTING GARAGE SHALL BE CONNECTED BACK TO NEW 200A HOUSE PANEL. PROVIDE NEW ELECTRICAL AS SHOWN.

6. WORK AT CRAWL SPACE: PROVIDE A NEW LIGHT FIXTURE NEAR EACH ACCESS HATCH (3-WAY SWITCH ON SAME CIRCUIT).

PROVIDE (1) OUTLET NEAR HATCH AT PANTRY. COORDINATE ANY ADDITIONAL ELECTRICAL REQUIREMENTS FOR NEW

ON-DEMAND WATER HEATER OR OTHER NEW WORK.

7. CONTRACTOR IS RESPOSIBLE FOR PROVIDING A COMPLETE ELECTRICAL SYSTEM IN RESIDENCE. INSURE THAT NEW AND

EXISTING TO REAMIN ELECTRICAL SYSTEMS MEET THE CURRENT NFPA 70 NATIONAL ELECTRICAL CODE.

8. ROUTE EXISTING ELECTRICAL CIRCUITS TO NEW JUNCTION BOX LOCATED NEAR EXISTING ELECTRICAL PANEL. CONNECT

NEW JUNCTION BOX TO NEW PANEL.

GENERAL ELECTRICAL NOTES

E2.1C.dwg
A2.1C