This is a technical drawing specification for a steel end panel with 4-strand barbed wire fence, prepared by the United States Department of the Interior, Bureau of Land Management, Pecos District Operations Office in Roswell, New Mexico. The drawing, numbered 323116-3), was created in January 2022 and designed by R. Fox, reviewed by B. Crawford, and approved by R. Porter.
The specification details the construction requirements for a fence end panel assembly, including brace anchor blocks measuring approximately 16" x 16" x 16" centered in anchor blocks, a 16" x 16" x 16" concrete base, and a cylindrical concrete footing with a minimum depth of 39 inches and 10-inch diameter. The steel angle base shall be centered in the diameter and positioned approximately 3 inches above the bottom of the cylinder. The twisted wire fence stays are placed at 16-6" on center between T-posts, with wire attached according to a spacing diagram. The panel consists of 2-inch to 2-1/2" inch by 2-1/2" x 1/4" steel upright posts and steel angle braces, with wire length varying based on topography. The fastening detail specifies 7-inch diameter bolts with nuts and washers per contract specifications, and utilizes twisted wire, 3/8" x 48" rebar (Grade 40) or 48" juniper cedar with a 2-inch minimum diameter throughout.