A06_Drainage_Crossing.pdf

PDF 127 KB Posted

Attached to
BLM-NM RFO COMANCHE OXBOW FENCING
Solicitation number
140L1726R0009
Issued by

About this file

This file is a technical specification drawing for a typical drainage crossing design. The document is a detailed engineering schematic produced by the United States Department of the Interior, Bureau of Land Management, Pecos District Operations Office in Roswell, New Mexico, dated January 2022.

The drawing illustrates a four-strand barbed wire fence configuration designed to span drainage crossings. The design specifies 18" x 16" x 16" concrete installations on both sides of the drainage area, with 16" x 16" x 16" concrete on the right side. The diagram includes a wire spacing diagram detail and notes that attachment wires should be placed on the downstream side of the drainage crossing, with topography dictating the actual configuration. The specification requires additional gaps to be filled with the same wire used on the bottom strand, with wire terminating at each panel and single metal post to create "breakaway" sections within the drainage crossing. The drawing was designed by DSW, reviewed by R. Fox and B. Crawford, and approved by R. Porter, with a drawing number of 323116(DX) and scale noted as NTS (Not To Scale).

View the file

Other files

File Type Posted
B11_Q_A_2_140L1726R0009_0004.pdf PDF
Sol_140L1726R0009_Amd_0004.pdf PDF
B11_Q_A_1_140L1726R0009_0003.pdf PDF
A04_UPDATED_SOW_BLM-NM_RFO_COMANCHE_OXBOW_FENCING_v_09_02_2026_0003.pdf PDF
B08_UPDATED_TERMS_AND_CONDITIONS_v_09_02_2026_0003.pdf PDF
A04_UPDATED_BID_SHEET_COMANCHE_OXBOW_FENCING_v_09_02_2026_0003.pdf PDF
Sol_140L1726R0009_Amd_0003.pdf PDF
B11_Q_A_140L1726R0009_0002.pdf PDF
B08_UPDATED_TERMS_AND_CONDITIONS_v_08_28_2026_0002.pdf PDF
Sol_140L1726R0009_Amd_0002.pdf PDF
A04_UPDATED_BID_SHEET_COMANCHE_OXBOW_FENCING_v_08_28_2026_0002.pdf PDF
Sol_140L1726R0009_Amd_0001.pdf PDF
B03_NM20260010_0001.pdf PDF
B08_UPDATED_TERMS_AND_CONDITIONS_v_08_27_2026_0001.pdf PDF
A04_UPDATED_SOW_BLM-NM_RFO_COMANCHE_OXBOW_FENCING_v_08_27_2026_0001.pdf PDF
A04_UPDATED_BID_SHEET_COMANCHE_OXBOW_FENCING_v_08_27_2026_0001.pdf PDF
Sol_140L1726R0009.pdf PDF
A06_ASTM-A121-04-Metallic-Coated-Carbon-Steel-Barbed-Wire-28_(1).pdf PDF
A06_Wire_Gate_Metal_with_Wood_Gate_Posts.pdf PDF
A06_Angle_Iron_fence_posts_ASTMspecA702-89.pdf PDF
A06_Corner_Panel_Metal.pdf PDF
A06_OXBOW_CAMANCHE_FENCE_MAP.pdf PDF
A06_Stress_Panel_Metal.pdf PDF
A06_Corner_Panel_Metal_Obtuse_Angle.pdf PDF
A04_SOW_BLM-NM_RFO_COMANCHE_OXBOW_FENCING.pdf PDF
A04_BID_SHEET_COMANCHE_OXBOW_FENCING.pdf PDF
A06_End_Panel_Metal.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

File details come from the government source that posted it. Updated .