8j. Signage Legend for Bldgs 1-230,CBOCs.pdf
PDF 4 MB Posted
- Solicitation number
- 36C25226B0001
About this file
This file is a comprehensive signage legend document for Building 1 at the Edward Hines Jr. VA Hospital, detailing a complete wayfinding signage update project. The document provides an exhaustive room-by-room breakdown of signage requirements across multiple floors (first through fourth), covering various departments including Medical Research, Nursing Services Administration, Director's Suite, Clinical Informatics, and numerous other administrative and clinical spaces. The signage legend includes specific details for each sign, such as room number, new sign text, department, sign type identification, and mounting type, with a total of 2,197 signs planned for Building 1 alone.
The signage package is part of Project 578-15-008, which involves updating wayfinding signage across multiple buildings at the Hines VA Hospital campus. The document is extremely detailed, specifying mounting instructions, installation guidelines, and precise locations for each sign, with various mounting types including wall mount, ceiling mount, flag mount, and panel and post configurations. The signs are categorized by type, such as primary, secondary, back-of-house, exam/conference, restroom, and directional signs, with specific considerations for accessibility, visibility, and departmental identification. The project appears to be comprehensive, covering not just Building 1 but multiple buildings across the VA hospital campus.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EDWARD HINES JR. VA HOSPITAL
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 2 Signage Package - 100% Construction Documents
2/17/2023 Guidon P# 19.6001.08
GENERAL MOUNTING HEIGHT AND INSTALLATION NOTES
• THE CONTRACTOR & SIGNAGE VENDOR ARE RESPONSIBLE FOR DETERMINING THE BEST METHOD OF
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
• POSITION SIGNS WITH A CLEAR LINE OF SIGHT FROM THE VIEWING POINT TO THE SIGN FACE. SIGNS
SHOULD BE INSTALLED TO BE PERPENDICULAR TO THE INTENDED VIEWER.
MOUNTING TYPE
REFER TO INDIVIDUAL SIGNAGE ELEVATIONS AND SIGNAGE REPORTS FOR RECOMMENDED INSTALLATION DETAIL
AND METHOD FOR EACH SIGN.
A - WALL MOUNT - SCREW MOUNT IS THE PREFERRED METHOD FOR WALL MOUNTED SIGN AS LONG AS THE
SUBSTRATE ALLOWS.
B - WALL MOUNT (ALTERNATE) - MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE TO BE USED IF
SUBSTRATE DOES NOT ALLOW A SCREW MOUNT EXAMPLE: GLASS
C. PANEL AND POST (EXTERIOR) - CONTRACTOR IS RESPONSIBLE FOR PROPERLY SURVERY SITE AND SECURING
POSTS IN THE GROUND.
D - EXTERIOR SCREW MOUNT STAND-OFFS (NOT PREFERRED METHOD) - CONTRACTOR IS RESPONSIBLE FOR
FOLLOWING ALL HISTORIC PRESERVATION REQUIREMENTS TO SAFELY INSTALL SIGNAGE ON ANY EXTERIOR
BUILDINGS, AS NEEDED.
E. CEILING MOUNT - 1/4" DIAMETER THREAD ROD - CONTRACTOR IS RESPONSIBLE FOR VERIFYING CEILING
HEIGHTS PRIOR TO INSTALLATION. WHERE THIS METHOD IS USED A MINIMUM CLEARANCE OF 80" ABOVE THE
FINISHED FLOOR MUST BE MAINTAINED. THREAD ROD IS TO BE SCREWED DIRECTLY INTO THE CEILING OR
FASTENED TO ACOUSTICAL CEILING GIRD WITH A GRID CLIP
F. FLAG MOUNT – WALL MOUNTED FLAG MUST BE INSTALLED WITH A MINIMUM CLEARANCE OF 80” ABOVE THE
FINISHED FLOOR.
G. MONUMENTAL WITH CONCRETE FOUNDATION (EXTERIOR)
H. POLE MOUNT - SIGN TO BE SECURED ON EXISTING EXTERIOR LAMP POSTS WITHIN THE PARKING LOTS.
Total Building 2 Signage = 155
Primary – IN-04.01 49
Secondary – IN-04.02 32
BOH – IN-03.01 11
Exam/Conference – IN-07.05 4
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 6
Stairs IN-01.11 6
Elevator IN-09.08 3
Restroom – IN-09.01, 02, 03 5
Baby Changing – IN-09.08 0
Notice – IN-10.01 4
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 0
Guide 1 Line – Ceiling – IN-15.55 2
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 0
Guide Med. Wall – IN-14.16 4
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 7
Guide Flag – IN-13.01 14
Guide Map – IN-17.00 0
Directory – IN-17.05 2
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141 p: 708-202-8387 x 21149 e: Jake.Kanuru@va.gov
ARCHITECT
GUIDON DESIGN
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 e: luke@guidondesign.com
BUILDING 2
SIGN ID
ROOM
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
0001 001 ELECTRIC SHOP ENGINEERING SERVICE IN-03.01 A
EXISTING DANGER AND RESTRICTED SIGNAGE TO REMAIN. Sign is cage mounted.
0002 002 STORAGE ENGINEERING SERVICE IN-04.02 A
0003 004 OFFICE ENGINEERING SERVICE IN-04.01 A
0004 004 OFFICE ENGINEERING SERVICE IN-04.01 A
0005 006 STORAGE ENGINEERING SERVICE IN-04.02 A
0006 008 STORAGE ENGINEERING SERVICE IN-04.02 A
0007 B05R STORAGE ENGINEERING SERVICE IN-04.02 A
0008 010 HAC Environmental Management Service (EMS) IN-04.02 A RESTRICTED AUTHORIZED PERSONNEL ONLY SIGN TO REMAIN
0009 B03R STAIRS N/A IN-01.10 A
0009A STAIRS N/A IN-13.01 F
0009B BASEMENT N/A IN-11.01 A
0010 B03R
(TITLE) STAIR NO ROOF ACCESS <N/L>
BASEMENT <N/L>
EXIT FLOOR 1<N/L>
BASEMENT THROUGH 2 N/A IN-01.11 A
0011 012 STAFF LOUNGE / LOCKER ENGINEERING SERVICE IN-04.01 A
0012 012 STAFF LOUNGE / LOCKER ENGINEERING SERVICE IN-04.01 A
0013 014 HAC Environmental Management Service (EMS) IN-04.02 A
0014 09R MECHANICAL ENGINEERING SERVICE IN-03.01 A
0015 016 WORK ROOM ENGINEERING SERVICE IN-04.01 A
0016 016A BATTERY ROOM ENGINEERING SERVICE IN-03.01 A
0017 BUILDING 1 N/A IN-15.55 E
0018 018 IRM TELEPHONE ENGINEERING SERVICE IN-03.01 A INSTALLATION ON CMU WALL
0019 08R ELEVATOR N/A IN-09.08 A
0019A ELEVATOR N/A IN-13.01 F
0020 018A ELECTRICAL MACHINE ROOM ENGINEERING SERVICE IN-03.01 A EXISTING HIGH VOLTAGE SIGN TO REMAIN
0021A BASEMENT N/A IN-11.01 A
(TITLE) BASEMENT<N/L>
(LEFT) ENGINEERING OFFICES 009, 030, 036, 038 <N/L>
(LEFT) STAIRS <N/L>
(RIGHT) ENGINEERING OFFICES 002,004, 006 <N/L>
(RIGHT) ELEVATORS <N/L>
(RIGHT) ELECTRICAL SHOP
N/A IN-14.16 A
0023 020 MEN N/A IN-09.01 A
0023A RESTROOM N/A IN-13.01 F
0024 022 Telecommunications OI&T IN-03.01 A
0025 024A STAFF LOUNGE ENGINEERING SERVICE IN-04.01 A INSTALLATION ON CAGE
0026 024 STAFF LOUNGE ENGINEERING SERVICE IN-04.01 A
0027 B06R STAIRS N/A IN-01.10 A
0027A STAIRS N/A IN-13.01 F
BUILDING 2 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
BASEMENT
Legend is sorted by sign ID. Refer to signage plans to locate each sign ID according to sequential order of rooms.
NOT USED
Page 1 of 6 Building 2 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 2 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage plans to locate each sign ID according to sequential order of rooms.
0027B
(TITLE) STAIR NO ROOF ACCESS <N/L>
BASEMENT <N/L>
EXIT FLOOR 1<N/L>
BASEMENT THROUGH 2 N/A IN-01.11 A
0027C BASEMENT N/A IN-11.01 A
0028 026 H.A.C. Environmental Management Service (EMS) IN-04.02 A
0028A ENGINEERING A.C. ENGINEERING SERVICE IN-03.01 A
0029 028 STORAGE ENGINEERING SERVICE IN-04.02 A INSTALLATION ON CMU WALL
0030 B11R OFFICE ENGINEERING SERVICE IN-04.01 A INSTALLATION ON CMU WALL
0031 B030 OFFICE ENGINEERING SERVICE IN-04.01 A
0033 038 OFFICE ENGINEERING SERVICE IN-04.01 A
0034 036 STORAGE ENGINEERING SERVICE IN-04.02 A
0035 034 STORAGE ENGINEERING SERVICE IN-04.02 A
0036 034 STORAGE ENGINEERING SERVICE IN-04.02 A INSTALLATION ON CMU WALL
0037 011A OFFICE ENGINEERING SERVICE IN-04.01 A
0038 011B STORAGE ENGINEERING SERVICE IN-04.02 A
0040 009 PROJECT PLANNING STORAGE ENGINEERING SERVICE IN-04.02 A
0041 009 PROJECT PLANNING STORAGE ENGINEERING SERVICE IN-04.02 A INSTALLATION ON CMU WALL
0042 009 PROJECT PLANNING STORAGE ENGINEERING SERVICE IN-04.02 A INSTALLATION ON CMU WALL
0043 B10R STORAGE - AC SHOP EMPLOYEES ONLY ENGINEERING SERVICE IN-04.02 A
0045 001A OFFICE ENGINEERING SERVICE IN-04.01 A
0046 001B STORAGE ENGINEERING SERVICE IN-04.02 A
(TITLE) BASEMENT<N/L>
(LEFT) ENGINEERING WORK ROOM<N/L>
(LEFT )TO BUILDING 1 N/A IN-14.16 A
1000 100 OFFICE Environmental Management Service (EMS) IN-04.01 A
1001 102 OPEN OFFICE Environmental Management Service (EMS) IN-04.01 A
1003 102 OPEN OFFICE Environmental Management Service (EMS) IN-04.01 A
1004 102A STORAGE Environmental Management Service (EMS) IN-04.02 A
1005 104 HAC Environmental Management Service (EMS) IN-04.02 A
1007 103R STAIRS N/A IN-01.10 A
1007A STAIRS N/A IN-13.01 F
NOT USED
FIRST FLOOR
NOT USED
NOT USED
Page 2 of 6 Building 2 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 2 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage plans to locate each sign ID according to sequential order of rooms.
1007B
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 1<N/L>
EXIT FLOOR 1<N/L>
BASEMENT THROUGH 2 IN-01.11 A
1008 106 Telecommunications OI&T IN-03.01 A
1010 106A OFFICE Environmental Management Service (EMS) IN-04.01 A
1011 108 OFFICE Environmental Management Service (EMS) IN-04.01 A
1013 110 WOMEN N/A IN-09.02 A
1013A RESTROOM N/A IN-13.01 F
(TITLE) FLOOR 1<N/L>
(RIGHT) ENGINEERING CONFERENCE ROOM 126 <N/L>
(LEFT) DIRECTOR'S SAFETY OFFICE SUITE 103<N/L>
(LEFT) ENVIRONMENTAL MANAGEMENT SERVICE OFFICE<N/L>
(LEFT) SUITE 102<N/L>
(RIGHT) ENGINEERING OFFICES 115-142
N/A IN-14.16 A
1015 106R MECHANICAL ENGINEERING SERVICE IN-03.01 A
1015A
1017 BUILDING 2 N/A IN-15.55 E
1018 120 STORAGE N/A IN-04.02 A
1019 114 STORAGE SAFETY IN-04.02 A
1020 114A STORAGE SAFETY IN-04.02 A
BUILDING 2 <N/L>
ENGINEERING SERVICE BASEMENT <N/L>
FLOOR 1 <N/L>
FLOOR 2 <N/L>
ENVIRONMENTAL MANAGEMENT SERVICE FLOOR 1 <N/L>
FISCAL SERVICE FLOOR 2 <N/L>
LOGISTICS SERVICE FLOOR 2 <N/L>
SAFETY FLOOR 1 <N/L>
VISIN 12 FLOOR 2 <N/L> N/A IN-17.05 A
1021A FLOOR 1 N/A IN-11.01 A
1022 108R ELEVATOR N/A IN-09.08 A
1022A ELEVATOR N/A IN-13.01 F
1023 124 MEN N/A IN-09.01 A
1023A RESTROOM N/A IN-13.01 F
1024 126 CONFERENCE ENGINEERING SERVICE IN-07.05 A
1025 N/A DEMO N/A N/A N/A DEMO
1026A 128 HAC Environmental Management Service (EMS) IN-04.02 A
1026 109R STAIRS N/A IN-01.10 A
NOT USED
NOT USED
NOT USED
Page 3 of 6 Building 2 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 2 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage plans to locate each sign ID according to sequential order of rooms.
1026B
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2<N/L>
EXIT FLOOR 1<N/L>
BASEMENT THROUGH 2 N/A IN-01.11 A
1026C STAIRS N/A IN-13.01 F
1027 130 STORAGE ENGINEERING SERVICE IN-04.02 A
1028 138 OPEN OFFICE ENGINEERING SERVICE IN-04.01 A
1029 142 OFFICE ENGINEERING SERVICE IN-04.01 A
1030 142 OFFICE ENGINEERING SERVICE IN-04.01 A
1031 134 OFFICE ENGINEERING SERVICE IN-04.01 A
1032 N/A DEMO N/A N/A N/A DEMO
1033 N/A DEMO N/A N/A N/A DEMO
1034 121 OPEN OFFICE ENGINEERING SERVICE IN-04.01 A
1035 N/A DEMO N/A N/A N/A DEMO
1036 117 OFFICE ENGINEERING SERVICE IN-04.01 A
1037 119 OFFICE ENGINEERING SERVICE IN-04.01 A
1039 115 OFFICE ENGINEERING SERVICE IN-04.01 A
1040 113 OFFICE ENGINEERING SERVICE IN-04.01 A
1041 111A CONFERENCE ENGINEERING SERVICE IN-07.05 A
1042 111B CONFERENCE Environmental Management Service (EMS) IN-07.05 A
1043 109 OFFICE ENGINEERING SERVICE IN-04.01 A
1044 107 OFFICE ENGINEERING SERVICE IN-04.01 A
1046 107A OFFICE ENGINEERING SERVICE IN-04.01 A
1048 105 OFFICE ENGINEERING SERVICE IN-04.01 A
1050 103 RECEPTION SAFETY IN-04.01 A
1051 101 OFFICE SAFETY IN-04.01 A
1052 101A OPEN OFFICE SAFETY IN-04.01 A
1053 N/A DEMO N/A N/A N/A DEMO
1054 101C OFFICE SAFETY IN-04.01 A
1055 101B OFFICE SAFETY IN-04.01 A
1057 101R STORAGE SAFETY IN-04.02 A
1059 N/A DEMO N/A N/A N/A DEMO
2000 200 OFFICE FISCAL SERVICE IN-04.01 A
2001 202 CONFERENCE FISCAL SERVICE IN-07.05 A
2003 204A OFFICE FISCAL SERVICE IN-04.01 A
2004 204 OFFICE FISCAL SERVICE IN-04.01 A
2005 206 STORAGE FISCAL SERVICE IN-04.02 A
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
NOT USED
SECOND FLOOR
Page 4 of 6 Building 2 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 2 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage plans to locate each sign ID according to sequential order of rooms.
2006 208 HAC Environmental Management Service (EMS) IN-04.02 A
2008A STAIRS N/A IN-13.01 F
2008B
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2<N/L>
EXIT FLOOR 1<N/L>
BASEMENT THROUGH 2 N/A IN-01.11 A
2008C FLOOR 2 N/A IN-11.01 A
2008 205R STAIRS N/A IN-01.10 A
2009 203 OPEN OFFICE FISCAL SERVICE IN-04.01 A
2010 210A COPY ROOM FISCAL SERVICE IN-04.02 A
2011 210B LOUNGE FISCAL SERVICE IN-04.02 A
2012 212 WOMEN N/A IN-09.02 A
2012A RESTROOM N/A IN-13.01 F
2013 216A ELECTRICAL ENGINEERING SERVICE IN-03.01 A
2014 216 OPEN OFFICE LOGISTICS SERVICE IN-04.01 A
2015 204R ELEVATOR N/A IN-09.08 A
2015A FLOOR 2 N/A IN-11.01 A
2015B ELEVATOR N/A IN-13.01 F
BUILDING 2 <N/L>
ENGINEERING SERVICE BASEMENT <N/L>
FLOOR 1 <N/L>
FLOOR 2 <N/L>
ENVIRONMENTAL MANAGEMENT SERVICE FLOOR 1 <N/L>
FISCAL SERVICE FLOOR 2 <N/L>
LOGISTICS SERVICE FLOOR 2 <N/L>
SAFETY FLOOR 1 <N/L>
VISIN 12 FLOOR 2 <N/L> N/A IN-17.05 A
2017 218 MEN N/A IN-09.01 A
2017A RESTROOM N/A IN-13.01 F
2018 220 OFFICE LOGISTICS SERVICE IN-04.01 A
2019 222A OFFICE LOGISTICS SERVICE IN-04.01 A
2021B STAIRS N/A IN-13.01 F
2021A
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2<N/L>
EXIT FLOOR 1<N/L>
BASEMENT THROUGH 2 N/A IN-01.11 A
2020 206 STORAGE N/A IN-04.02 A
2021 206R STAIRS N/A IN-01.10 A
2022 224 HAC Environmental Management Service (EMS) IN-04.02 A
2023 226 STORAGE FISCAL SERVICE IN-04.02 A
2024 230 OPEN OFFICE FISCAL SERVICE IN-04.01 A
2025 FLOOR 2 N/A IN-11.01 A
2026 215 OFFICE FISCAL SERVICE IN-04.01 A
2027 215C OFFICE FISCAL SERVICE IN-04.01 A
2028 215B OFFICE FISCAL SERVICE IN-04.01 A
Page 5 of 6 Building 2 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 2 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage plans to locate each sign ID according to sequential order of rooms.
2029 209 Telecommunications OI&T IN-03.01 A
(TITLE) FLOOR 2<N/L>
(RIGHT) FISCAL OFFICE 200-210 <N/L>
(LEFT) A&MM WAREHOUSE<N/L>
(LEFT) FISCAL OFFICE 215-230 <N/L>
N/A IN-14.16 A
2031 207 OFFICE LOGISTICS SERVICE IN-04.01 A
2033 205A OFFICE ENGINEERING SERVICE IN-04.01 A
2034 205A OFFICE ENGINEERING SERVICE IN-04.01 A
Page 6 of 6 Building 2 Signage Legend
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 3 Signage Package - 100% Construction Documents
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
Total Building 3 Signage = 29
Primary – IN-04.01 5
Secondary – IN-04.02 11
BOH – IN-03.01 3
Exam/Conference – IN-07.05 0
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 0
Stairs IN-01.11 0
Elevator IN-09.08 0
Restroom – IN-09.01, 02, 03 1
Baby Changing – IN-09.08 0
Notice – IN-10.01 2
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 1
Guide 1 Line – Ceiling – IN-15.55 1
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 1
Guide Med. Wall – IN-14.16 2
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 0
Guide Flag – IN-13.01 2
Guide Map – IN-17.00 0
Directory – IN-17.05 0
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202
BUILDING 3
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
(TITLE) FIRST FLOOR<N/L>
(RIGHT) BUILDING 3 PIPE SHOP <N/L>
(RIGHT) LOADING DOCK <N/L>
(LEFT) BUILDING 1 N/A IN-14.16 A
0001A
(SIDE 1)
(STRAIGHT) PIPE SHOP
(SIDE 2)
(STRAIGHT) BUILDING 1 N/A IN-15.55 E
101R
BUILDING 3
SHOPS Engineering Service IN-04.01 A
0002A (LEFT) TO BUILDING 1 N/A IN-14.15 A
0003 101 RESTROOMS N/A IN-09.03 A
0003A RESTROOMS N/A IN-13.01 F
0003B RESTROOMS N/A IN-13.01 F
0004 102 LOCKER Engineering Service IN-04.02 A
0005 103A PIPE FITTING Engineering Service IN-04.02 A
0005A 103 STORAGE Engineering Service IN-04.02 A
0005B 104 STORAGE Engineering Service IN-04.02 A
0005C
(TITLE) FIRST FLOOR<N/L>
(RIGHT)LOADING DOCK<N/L>
(RIGHT) ROOMS 103-110<N/L>
(LEFT) RESTROOM/LOCKERS N/A IN-14.16 A
SHOPS
OFFICE Engineering Service IN-04.01 A
106A
SHOPS
OFFICE Engineering Service IN-04.01 A
0008 107 OFFICE Engineering Service IN-04.01 A
0009 107 OFFICE Engineering Service IN-04.01 A
0010 108 STORAGE Engineering Service IN-04.02 A
0011 108 STORAGE Engineering Service IN-04.02 A
0012 113 EQUIPMENT STORAGE Engineering Service IN-04.02 A
0012A 109 TELECOMMUNICATION OI&T IN-03.01 A
FIRST FLOOR
BUILDING 3 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
Page 1 of 2 Building 2 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
FIRST FLOOR
BUILDING 3 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0012B
(SIDE 1)
(STRAIGHT) LOADING DOCK
(RIGHT) STAFF LOUNGE
(SIDE 2)
(LEFT) STAFF LOUNGE Engineering Service IN.15.56 E
0013 114 STAFF LOUNGE Engineering Service IN-04.02 A
0014 100 MECHANICAL Engineering Service IN-03.01 A
0015 109 STORAGE Engineering Service IN-04.02 A
0016 110 STAFF LOUNGE Engineering Service IN-04.02 A
0016A N/A N/A IN-10.01 A VA TO DETERMINE NOTICE INFORMATION
0016B N/A N/A IN-10.01 A VA TO DETERMINE NOTICE INFORMATION
0017 111 PIPE FITTING Engineering Service IN-04.02 A
0018 113 ELECTRICAL Engineering Service IN-03.01 A
Page 2 of 2 Building 2 Signage Legend
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 4 Signage Package - 100% Construction Documents
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
Total Building 4 Signage = 32
Primary – IN-04.01 13
Secondary – IN-04.02 6
BOH – IN-03.01 4
Exam/Conference – IN-07.05 2
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 0
Stairs IN-01.11 0
Elevator IN-09.08 0
Restroom – IN-09.01, 02, 03 2
Baby Changing – IN-09.08 0
Notice – IN-10.01 2
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 1
Guide 1 Line – Ceiling – IN-15.55 1
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 0
Guide Med. Wall – IN-14.16 0
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 0
Guide Flag – IN-13.01 1
Guide Map – IN-17.00 0
Directory – IN-17.05 0
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202
BUILDING 4
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
0001 102-4 COPY ROOM Caregiver Support IN-04.02 A
0002 125-4 OFFICE Caregiver Support IN-04.01 A
0003 124-4 OFFICE Caregiver Support IN-04.01 A
0004 123-4 OFFICE Caregiver Support IN-04.01 A
0005 122-4 OFFICE Caregiver Support IN-04.01 A
0006 121-4 OFFICE Caregiver Support IN-04.01 A
0007 120-4 STAFF LOUNGE Caregiver Support IN-04.02 A
0008 119-4 WOMEN N/A IN-09.02 A ADD ACCESSABILITY SYMBOL
0009 117-4 STORAGE Environmental Management Service (EMS) IN-04.02 A
0009A RESTROOM N/A IN-13.01 F
0010 118-4 MEN N/A IN-09.01 A ADD ACCESSABILITY SYMBOL
0011 116-4 FILE ROOM TENANT TBD IN-04.02 A
0012 115-4 OFFICE Caregiver Support IN-04.01 A
0013 114-4 OFFICE Caregiver Support IN-04.01 A
0014 113-4 OFFICE Caregiver Support IN-04.01 A
0015 112-4 OFFICE Caregiver Support IN-04.01 A
0016 111-4 OFFICE Caregiver Support IN-04.01 A
0017 110-4 OFFICE Caregiver Support IN-04.01 A
0018 109-4 OFFICE Caregiver Support IN-04.01 A
0019 108-4 OFFICE Caregiver Support IN-04.01 A
0020 107-4 ELECTRICAL Engineering IN-03.01 A
0020A 108A TELECOMMUNICATIONS OI&T IN-03.01 A
0020B TELECOMMUNICATIONS OI&T IN-03.01 A
0021 106-4 CONFERENCE Caregiver Support IN-07.05 A
0022 106-4 CONFERENCE Caregiver Support IN-07.05 A
0022A
(SIDE 1)
(STRAIGHT) RESTROOMS<N/L>
(STRAIGHT) ROOMS 106-125
(SIDE 2) (BLANK) N/A IN-15.56 E
0023 103-4 FIRE PROTECTION Engineering IN-03.01 A
0024 100 RECEPTION Caregiver Support IN-04.02 A
0024A
(SIDE 1) RECEPTION
(SIDE 2) BLANK Caregiver Support IN-15.55 E
0025 101-4 STORAGE Caregiver Support IN-04.02 A
0025A N/A N/A IN-10.01 A NOTICE INFORMATION PROVIDED BY VA
0025B N/A N/A IN-10.01 A NOTICE INFORMATION PROVIDED BY VA
BUILDING 4 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
FIRST FLOOR
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
Page 1 of 1 Building 4 Signage Legend
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 7 Signage Package - 100% Construction Documents
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
Total Building 7 Signage = 44
Primary – IN-04.01 5
Secondary – IN-04.02 19
BOH – IN-03.01 1
Exam/Conference – IN-07.05 0
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 2
Stairs IN-01.11 2
Elevator IN-09.08 2
Restroom – IN-09.01, 02, 03 1
Baby Changing – IN-09.08 0
Notice – IN-10.01 3
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 0
Guide 1 Line – Ceiling – IN-15.55 0
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 0
Guide Med. Wall – IN-14.16 2
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 2
Guide Flag – IN-13.01 5
Guide Map – IN-17.00 0
Directory – IN-17.05 0
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202
BUILDING 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
0001 108A SHOP Engineering Service IN-04.02 A
0002 107 STORAGE Engineering Service IN-04.02 A
0003 107 STORAGE Engineering Service IN-04.02 A
0004 103A RESTROOMS Environmental Management Services (EMS) IN-09.03 A
0004A RESTROOMS N/A IN-13.01 F
0005 106 STORAGE Engineering Service IN-04.02 A
0006 109 STORAGE Engineering Service IN-04.02 A
0007 111 STORAGE Engineering Service IN-04.02 A
0008 110 STORAGE Engineering Service IN-04.02 A
0009 104 SUPPLY STORAGE Engineering Service IN-04.02 A
0010 101 OFFICE Engineering Service IN-04.01 C BRICK WALL
0011 101 SHOP Engineering Service IN-04.01 A
0012 107C CORRIDOR Engineering Service IN-04.02 A
0012A N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0012B N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0012C N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0013 103 SHOP Engineering Service IN-04.02 A
0015 ELEVATOR Engineering IN-13.01 F
0015A
FLOOR ONE
BUILDING 7 N/A IN-11.01 A
0016 102R ELEVATOR N/A IN-09.08 A
0017 101R STAIRS N/A IN-01.10 A
0017A IG5 STAIR N/A IN-13.01 F
0017B
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 1 <N/L>
EXIT UP FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0018 105 CARPENTER SHOP Engineering Service IN-04.02 A
0019 107C TOOL ROOM Engineering Service IN-04.02 A
0020 208 BREAK ROOM Engineering Service IN-04.02 A
0020A 210B TELECOMMUNICATION OIT IN-03.01 A
0021 210C SHOP Engineering Service IN-04.02 A
SECOND FLOOR
BUILDING 7 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
FIRST FLOOR
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
Page 1 of 2 Building 7 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 7 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0022 IG3
(TITLE) FLOOR 2 <N/L>
(LEFT) PAINT SHOP <N/L>
(LEFT) STAIRS <N/L>
(RIGHT) LOCK SHOP <N/L>
(RIGHT) SIGN SHOP <N/L>
(LEFT) LOCKER ROOM N/A IN-14.16 A
0023 211 LOCKERS Engineering Service IN-04.02 C BRICK WALL
0024 213 STORAGE Engineering Service IN-04.02 A
0025 214C PAINT SHOP Engineering Service IN-04.02 A
0025A
(TITLE) FLOOR 2<N/L>
(LEFT) PAINT ROOM<N/L>
(RIGHT)LOCKER ROOM<N/L>
(RIGHT)PAINT STORAGE N/A IN-14.16 A
0026 214 OFFICE Engineering Service IN-04.01 A
0026A 214B COMPUTER ROOM Engineering Service IN-04.01 A
0027 214 OFFICE Engineering Service IN-04.01 A
0028 204A.2
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2<N/L>
EXIT UP FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0029 204A STAIRS N/A IN-01.10 A
0030 ELEVATOR N/A IN-13.01 F
FLOOR TWO
BUILDING 7 N/A IN-11.01 A
0032 203R ELEVATOR N/A IN-09.08 A
0033 IG4 STAIR N/A IN-13.01 F
0034 209 SHOP Engineering Service IN-04.02 A
0034A 209 LOCK SMITH/LOCK SHOP Engineering Service IN-04.02 A
Page 2 of 2 Building 7 Signage Legend
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 8 Signage Package - 100% Construction Documents
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
Total Building 8 Signage = 80
Primary – IN-04.01 9
Secondary – IN-04.02 33
BOH – IN-03.01 4
Exam/Conference – IN-07.05 2
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 2
Stairs IN-01.11 2
Elevator IN-09.08 0
Restroom – IN-09.01, 02, 03 5
BabyChange/Accessibility – IN-09.08 0
Notice – IN-10.01 9
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 2
Guide 1 Line – Ceiling – IN-15.55 2
Guide 1 Line – Wall – IN-16.51 2
Guide Small Wall – IN-14.15 1
Guide Med. Wall – IN-14.16 2
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 0
Guide Flag – IN-13.01 5
Guide Map – IN-17.00 0
Directory – IN-17.05 0
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202
BUILDING 8
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
0001 103R ELECTRICAL Engineering IN-04.02 A
0002 D8 (SIDE 1) (STRAIGHT) BUILDING 8 N/A IN-15.56 A
0003 D7 (SIDE 2)(STRAIGHT) BUILDING 7 & 13 N/A IN-15.56 A
0004 101R OPEN OFFICE N/A IN-04.02 A CMU OR BRICK
0005 102 STORAGE N/A IN-04.02 A
0006 110A WELDING SHOP N/A IN-04.02 A
0007 108 LOCKERS N/A IN-04.02 A
0008 105R RESTROOM N/A IN-09.03 A
0008A RESTROOMS N/A IN-13.01 F
0009 105 STORAGE N/A IN-04.02 A
0009A (RIGHT) AC SHOP N/A IN-16.51 A
0009B (LEFT) BUILDING 1 N/A IN-16.51 A
0010 106R N/A N/A IN-03.01 A
0010A N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0010B N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0010C N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0011 COURTYARD N/A IN-04.02 A
0012 STORAGE N/A IN-04.02 A
0012A STORAGE N/A IN-04.02 A
0013 REPAIR SHOP N/A IN-04.02 A
0015 STORAGE N/A IN-04.02 A
0016 127 OFFICE Engineering IN-04.01 A
0017 STORAGE N/A IN-04.02 A
0019 STORAGE N/A IN-04.02 A
0020 112D LOUNGE N/A IN-04.02 A
0021 111B OFFICE Engineering IN-04.01 A
0021A OFFICE Engineering IN-04.01 A
0022 112C RESTROOM N/A IN-09.03 A
0022A RESTROOMS N/A IN-13.01 F
0023 112B TOOL ROOM N/A IN-04.02 A CMU OR BRICK
0024 106R MACHINE SHOP N/A IN-04.02 A
0025 3 PARTS ROOM N/A IN-04.02 A
0025A N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0025B N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0025C N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
BUILDING 8 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
FIRST FLOOR
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
NOT USED
Page 1 of 3 Building 8 Signage Legend
0026 STORAGE N/A IN-04.02 A CMU OR BRICK
0026A
(SIDE 1) (LEFT) AC SHOP
(SIDE 2) (RIGHT) AC SHOP N/A IN-15.55 E
0026B
(TITLE) FLOOR 1 <N/L>
(LEFT) BUILDING 1<N/L>
(RIGHT)AC SHOP N/A IN-14.16 A
0026C STAIRS N/A IN-13.01 F
0026D STAIRS N/A IN-01.10 A
0026E
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 1<N/L>
EXIT UP FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0027 111B PAINT ROOM N/A IN-04.02 A CMU OR BRICK
0028 110 STORAGE N/A IN-04.02 A
0029 110A WELDING SHOP N/A IN-04.02 A
0030 102R ELECTRICAL Engineering IN-03.01 C CMU OR BRICK
0040 D1
(SIDE 1) (STRAIGHT) TO BUILDING 1
(SIDE 2) (STRAIGHT) BUILDING 8 POLICE TRAINING CENTER N/A IN-15.55 E
0041 IG2
(TITLE) FLOOR 2<N/L>
(STRAIGHT) TO BUILDING 1 N/A IN-14.15 A
0041A STAIRS N/A IN-01.10 A
0041B
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2<N/L>
EXIT UP FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0041C STAIRS N/A IN-13.01 F
0042 N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0042A N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0042B N/A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0043 201 ELECTRICAL Engineering IN-03.01 A
0044 202 OFFICE Police Service IN-04.01 A
0045 203 RESTROOM N/A IN-09.03 A
0045A RESTROOMS N/A IN-13.01 F
0046 204 STORAGE N/A IN-04.02 A
0046A 203B RESTROOM N/A IN-03.01 A
0047 205 OFFICE Police Service IN-04.01 A
0048 206 OFFICE Police Service IN-04.01 A
0049 207 STORAGE N/A IN-04.02 A
0050 208 OFFICE Police Service IN-04.01 A
0051 209 STORAGE N/A IN-04.02 A
Page 2 of 3 Building 8 Signage Legend
0052 210 EQUIPMENT ROOM N/A IN-04.02 A
0053 211 EQUIPMENT ROOM N/A IN-04.02 A
0054 212 LOCKER ROOM N/A IN-09.02 A
0054A 212A RESTROOM N/A IN-09.03 A ADD ACCESSABILITY SYMBOL
0055 213 HAC Environmental Management Services (EMS) IN-04.02 A
0056 214 TRAINING ROOM Police Service IN-07.05 A
(TITLE) FLOOR 1 <N/L>
(LEFT) ROOMS 201-214<N/L>
(RIGHT)ROOMS 215-216C N/A IN-14.16
0058 215 OFFICE Police Service IN-04.01 A
0059 TRAINING ROOM Police Service IN-07.05 A
0059A 216A STORAGE N/A IN-04.02 A
0059B 216B STORAGE N/A IN-04.02 A
0059C 216C LOCKER ROOM N/A IN-04.02 A
0059D 216C LOCKER ROOM N/A IN-04.02 A
0059E 203 STORAGE Police Service IN-04.02 A
0060 200B H.A.C. Environmental Management Services (EMS) IN-04.02 A
0061 200 OFFICE Police Service IN-04.01 A
Page 3 of 3 Building 8 Signage Legend
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 9 Signage Package - 100% Construction Documents
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
Total Building 9 Signage = 62
Primary – IN-04.01 17
Secondary – IN-04.02 17
BOH – IN-03.01 2
Exam/Conference – IN-07.05 0
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 6
Stairs IN-01.11 4
Elevator IN-09.08 0
Restroom – IN-09.01, 02, 03 2
BabyChange/Accessibility – IN-09.08 0
Notice – IN-10.01 3
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 0
Guide 1 Line – Ceiling – IN-15.55 4
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 1
Guide Med. Wall – IN-14.16 1
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 0
Guide Flag – IN-13.01 5
Guide Map – IN-17.00 0
Directory – IN-17.05 0
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202
BUILDING 9
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID MOUNTING TYPE COMMENTS
0001 B01R MECHANICAL Engineering IN-03.01 A
0002-0009
0010 IN-0 ESCORT SERVICE DISPATCH OFFICE PAS IN-04.01 A
0010A
(SIDE 1) (LEFT) ESCORT SERVICE
(SIDE 2) (RIGHT) ESCORT SERVICE PAS IN-15.55 E
0011 105R STORAGE N/A IN-04.02 A
0011A 101E TELECOMMUNICATIONS OI&T IN-03.01 A
0012 107E OFFICE Voluntary Service IN-04.01 A
0013 107D OFFICE Voluntary Service IN-04.01 A
0014 107C OFFICE Voluntary Service IN-04.01 A
0015 107B STORAGE Voluntary Service IN-04.02 A
0019 107A OFFICE Voluntary Service IN-04.01 A
0019A OFFICE Voluntary Service IN-04.01 A
0020 107A OFFICE Voluntary Service IN-04.01 A
0020A N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0020B N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0020C N/A IN-10.01 A NOTICE INFORMATION TO BE DETERMINED BY VA
0021 107E OFFICE Voluntary Service IN-04.01 A
0022 106R STORAGE N/A IN-04.02 A
(SIDE 1) (STRAIGHT) RECREATIONAL THERAPY
(SIDE 2) (STRAIGHT) VOLUNTARY SERVICE N/A IN-15.55 E
0024 105 WOMEN N/A IN-09.02 A ADD ACCESSABILITY SYMBOL
0024A RESTROOMS N/A IN-13.01 F
0024B
(SIDE 1) (STRAIGHT) RECREATIONAL THERAPY
(SIDE 2) (STRAIGHT) VOLUNTARY SERVICE N/A IN-15.55 E
0026 108 OFFICE RECREATIONAL THERAPY IN-04.01 A
0027 108A OFFICE RECREATIONAL THERAPY IN-04.01 A
0028 108B OFFICE RECREATIONAL THERAPY IN-04.01 A
0029 109 MEN N/A IN-09.01 A ADD ACCESSABILITY SYMBOL
0030 110A KITCHEN Voluntary Service IN-04.01 A
0030A 110 BREAKROOM N/A IN-04.02 A
0031 106 HAC Environmental Management Services (EMS) IN-04.02 A
BUILDING 9 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
BASEMENT
FIRST FLOOR
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
NOT USED
NOT USED
NOT USED
NOT USED
Page 1 of 3 Building 9 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID MOUNTING TYPE COMMENTS
BUILDING 9 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0032 112 AUDITORIUM Voluntary Service IN-04.01 A
0033 112 AUDITORIUM Voluntary Service IN-04.01 A
0034 112 AUDITORIUM Voluntary Service IN-04.01 A
0035 101R STAIRS N/A IN-01.10 A
0035A
(TITLE) STAIR NO ROOF ACCESS <N/L>
LEVEL 1 <N/L>
EXIT FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0035B STAIRS N/A IN-13.01 F
0036 103 STORAGE RECREATIONAL THERAPY IN-04.02 A
0037 110 LOUNGE Voluntary Service IN-04.02 A
0038 102R STAIRS N/A IN-01.10 A
0039 103R STAIRS N/A IN-01.10 A
0041 102 STORAGE PAS IN-04.02 A
0042 101C STORAGE Voluntary Service IN-04.02 A
0043 101C STORAGE Engineering IN-04.02 A
0045 101-D BREAKROOM PAS IN-04.02 A
0046 101B OFFICE PAS IN-04.01 A
0048 101A OFFICE PAS IN-04.01 A
0049 101E LOCKER ROOM PAS IN-04.02 A
0050 IG3
(TITLE) Floor 1 <N/L>
(LEFT) BUILDING 1 N/A IN-14.15 A
0050A
(SIDE 1) (RIGHT) BUILDING 9
(SIDE 2) BLANK N/A IN-15.55 E
0050B
(TITLE) FLOOR 1<N/L>
(RIGHT) AUDITORIUM<N/L>
(RIGHT) VOLUNTEER SERVICES<N/L>
(RIGHT) RECREATION THERAPY N/A IN-14.16 A
0060 201R STAIRS N/A IN-01.10 A
0060A STAIRS N/A IN-13.01 F
SECOND FLOOR
NOT USED
NOT USED
Page 2 of 3 Building 9 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID MOUNTING TYPE COMMENTS
BUILDING 9 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0060B
(TITLE)(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2 <N/L>
EXIT FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0061 204B DRESSING ROOM N/A IN-04.02 A
0062 204C DRESSING ROOM N/A IN-04.02 A
0063 202R STAIRS N/A IN-01.10 A
0063A STAIRS N/A IN-13.01 F
0063B
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2<N/L>
EXIT FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
0064 204D STORAGE N/A IN-04.02 A
0065 204E PROJECT ROOM N/A IN-04.02 A
0066 204F STORAGE N/A IN-04.02 A
0067 STAIRS N/A IN-01.10 A
0067A STAIRS N/A IN-13.01 F
0067B
(TITLE)(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 2 <N/L>
EXIT FLOOR 1<N/L>
1 THROUGH 2 N/A IN-01.11 A
Page 3 of 3 Building 9 Signage Legend
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 16 Signage Package - 100% Construction Documents
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
Total Building 16 Signage = 144
Primary – IN-04.01 46
Secondary – IN-04.02 16
BOH – IN-03.01 13
Exam/Conference – IN-07.05 4
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 7
Stairs IN-01.11 7
Elevator IN-09.08 3
Restroom – IN-09.01, 02, 03 6
BabyChange/Accessibility – IN-09.08 0
Notice – IN-10.01 3
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 0
Guide 1 Line – Ceiling – IN-15.55 0
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 2
Guide Med. Wall – IN-14.16 11
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 9
Guide Flag – IN-13.01 16
Guide Map – IN-17.00 0
Directory – IN-17.05 1
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202
BUILDING 16
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID MOUNTING TYPE COMMENTS
0001 IG1 BASEMENT N/A IN-11.01 A
0001A STAIRS N/A IN-01.10 A
0001B
(TITLE) STAIR NO ROOF ACCESS <N/L>
BASEMENT <N/L>
EXIT FLOOR 1<N/L>
B THROUGH 3 N/A IN-01.11 A
0001C STAIRS N/A IN-13.01 F
0002 001 VACANT N/A IN-03.01 A
0003 002 VACANT N/A IN-03.01 A
0004 003 MECHANICAL Engineering IN-03.01 A
0005 000 MECHANICAL Engineering IN-03.01 A
0006 008 MECHANICAL Engineering IN-03.01 A
0007 006 TELECOMMUNICATIONS OI&T IN-03.01 A
0008 007 MECHANICAL Engineering IN-03.01 A
0009 005 MECHANICAL Engineering IN-03.01 A
0009A
(TITLE)BASEMENT<N/L>
(LEFT) ROOMS 2-6<N/L>
(RIGHT)STAIRS N/A IN-14.16 A
0010 004 MECHANICAL Engineering IN-03.01 A
1020 105R
(TITLE) STAIR NO ROOF ACCESS <N/L>
FLOOR 1 <N/L>
EXIT FLOOR 1<N/L>
B THROUGH 3 N/A IN-01.11 A
1020A 105R STAIRS N/A IN-01.10 A
1021 125 OFFICE Tenant Space IN-04.01 A
1022 IG2
(TITLE) FLOOR 1 <N/L>
(RIGHT) STAIRS <N/L>
(LEFT) RESTROOM<N/L>
(LEFT)CHECK-OUT N/A IN-14.16 A INSTALL UNDER 1061
1023 123 OFFICE Tenant Space IN-04.01 A
1024 121 MEN N/A IN-09.01 A ADD ACCESSABILITY SYMBOL
1024A RESTROOM N/A IN-13.01 F
1025 106R STORAGE N/A IN-04.02 A
1026 119 H.A.C. Environmental Management Service (EMS) IN-04.02 A
1027 117 STORAGE N/A IN-04.02 A
BUILDING 16 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
BASEMENT
FIRST FLOOR
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
Page 1 of 6 Building 16 Signage Legend
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID MOUNTING TYPE COMMENTS
BUILDING 16 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
1028 115 OFFICE Tenant Space IN-04.01 A
1028A
(TITLE) FLOOR 1 <N/L>
(LEFT) ROOMS 113-126 <N/L>
(LEFT) MEN'S RESTROOM<N/L>
(RIGHT) ELEVATOR/STAIRS<N/L>
(RIGHT)WOMEN'S RESTROOM N/A IN-14.16 A
1029 113 MECHANICAL Engineering IN-03.01 A
1030 111 BREAKROOM Tenant Space IN-04.01 A
1031 109 MECHANICAL Engineering IN-03.01 A
1032 108 WOMEN N/A IN-09.02 A ADD ACCESSABILITY SYMBOL
1032A RESTROOM N/A IN-13.01 F
1033 107 STORAGE N/A IN-04.02 A
1034 105 OFFICE Tenant Space IN-04.01 A
1035 109R STORAGE Tenant Space IN-04.02 A
1036 IG6
(TITLE) FLOOR 1 <N/L>
(RIGHT) RESTROOMS <N/L>
(LEFT) ELEVATOR/STAIRS<N/L>
(RIGHT) CHECK-OUT N/A IN-14.16 A INSTALL UNDER 1043
1037 103 STORAGE N/A IN-04.02 A
1038 IG5 FLOOR 1 N/A IN-11.01 A
1038A
(TITLE) FLOOR 1 <N/L>
(LE…