8b. Building 13 Signage Legend.pdf
PDF 815 KB Posted
- Solicitation number
- 36C25226B0001
About this file
This document is a Signage Legend and Mounting Instructions for Building 13 at the Edward Hines Jr. VA Hospital in Hines, Illinois, detailing a comprehensive wayfinding signage update project. The project involves installing 148 total signs across the basement, first, second, and third floors, with sign types including room identification, directional, directory, and departmental signage primarily for Mental Health, Engineering, and OI&T departments.
The document provides detailed mounting guidelines, specifying six different mounting types (wall mount, panel and post, ceiling mount, flag mount, monumental with concrete foundation, and pole mount), with specific installation requirements such as maintaining minimum clearance heights, ensuring signs do not block exit signs or fire sprinklers, and positioning signs with a clear line of sight. The project is being managed by Guidon Design for the VA Hines Medical Center, with key contacts including Jake Kanuru from the VA and Luke Leising from Guidon Design, and was developed as 100% construction documents on 10/28/2022.
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EDWARD HINES JR. VA HOSPITAL
578-15-008 – UPDATE WAYFINDING SIGNAGE
Building 13 Signage Package - 100% Construction Documents
10/28/2022 Guidon P# 19.6001.08
GENERAL MOUNTING HEIGHT AND INSTALLATION NOTES
• THE CONTRACTOR & SIGNAGE VENDOR ARE RESPONSIBLE FOR DETERMINING THE BEST METHOD OF
INSTALLATION BASED ON THE FINAL SIGNAGE SIZE, WEIGHT, AND DURABILITY TO MINIMIZE DAMAGE
TO THE EXISTING SUBSTRATES.
• IT IS RECOMMENDED THAT ALL INTERIOR SIGNAGE WITH A BACKPLATE BE SCREWED DIRECTLY INTO
THE MOUNTING SURFACE. MOUNTING HARDWARE SHOULD BE CONCEALED. IF SIGN IS NOT ABLE TO
BE MOUNTED WITH A SCREW THAN A MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE CAN BE
USED IF APPROVED BY THE VA FOR EACH CONDITION.
• CONTRACTOR IS RESPONSIBLE FOR ADHERING ALL SIGNAGE SO THAT IT IS STRUCTURLY SECURE.
• FOR EXTERIOR SITE SIGNAGE CONTRACTOR IS RESPONSIBLE FOR COMPLETING NECCESSARY SURVEYS
TO SAFELY SECURE SIGNAGE INTO THE GROUND OR MOUNTING SURFACE. THIS INCLUDES PROVIDING
FOUNDATION TO BELOW FROST LINE WHERE APPLICABLE
• ALL EXTERIOR SIGNS SHOULD BE LOCATED A MINIMUM OF 2'-0" FROM THE CURB. THE EXACT
LOCATION OF A SIGN WILL VARY DEPENDING ON THE TYPE OF SIGN AND SITE CONDITIONS. SIGN
PLACEMENT MUST BE CAREFULLY CONSIDERED TO ENSURE THAT THE SIGN FITS THE LOCATION
WITHOUT MAJOR REGRADING. IT MAY BE NECESSARY TO CLEAR EXISTING SHRUBS OR BUSHES OR
RELOCATE AN OBSTRUCTION. WHEN SIGNS ARE PLACED ON SLOPING OR INCLINED GRADES,
ADJUSTMENTS MUST BE MADE TO POST LENGTHS. EXTREME DIFFERENCES BETWEEN POST LENGTHS
SHOULD BE MINIMIZED.
• CONTRACTOR SHOULD FOLLOW THE VA SIGNAGE GUIDE FOR BOTH EXTERIOR, INTERIOR, AND
SPECIALTY SIGNS INSTALLATION AND VIEWING REQUIREMENTS.
• ALL ROOM IDENTIFICATION SIGNAGE IS TO BE INSTALLED ON THE PUBLIC SIDE AT THE LATCH SIDE OF
THE DOOR, 2" OVER FROM THE DOOR FRAME. ANY EXISTING CONDITIONS THAT DO NOT ALLOW THIS
MUST BE REVIEWED AND APPROVED BY THE VA.
• OVERHEAD SIGNS MUST NOT VISUALLY BLOCK EXIT SIGNS AND SHALL NOT BLOCK FIRE SPRINKLER
SPRAY PATTERNS. THEY MUST HAVE A MINIMUM 84 INCHES OF CLEARANCE FROM THE BOTTOM OF
THE SIGN TO THE FLOOR.
• POSITION SIGNS WITH A CLEAR LINE OF SIGHT FROM THE VIEWING POINT TO THE SIGN FACE. SIGNS
SHOULD BE INSTALLED TO BE PERPENDICULAR TO THE INTENDED VIEWER.
MOUNTING TYPE
REFER TO INDIVIDUAL SIGNAGE ELEVATIONS AND SIGNAGE REPORTS FOR RECOMMENDED INSTALLATION DETAIL
AND METHOD FOR EACH SIGN.
A - WALL MOUNT - SCREW MOUNT IS THE PREFERRED METHOD FOR WALL MOUNTED SIGN AS LONG AS THE
SUBSTRATE ALLOWS.
B - WALL MOUNT (ALTERNATE) - MANUFACTURER RECOMMENDED DOUBLE SIDED TAPE TO BE USED IF
SUBSTRATE DOES NOT ALLOW A SCREW MOUNT EXAMPLE: GLASS
C. PANEL AND POST (EXTERIOR) - CONTRACTOR IS RESPONSIBLE FOR PROPERLY SURVERY SITE AND SECURING
POSTS IN THE GROUND.
D - EXTERIOR SCREW MOUNT STAND-OFFS (NOT PREFERRED METHOD) - CONTRACTOR IS RESPONSIBLE FOR
FOLLOWING ALL HISTORIC PRESERVATION REQUIREMENTS TO SAFELY INSTALL SIGNAGE ON ANY EXTERIOR
BUILDINGS, AS NEEDED.
E. CEILING MOUNT - 1/4" DIAMETER THREAD ROD - CONTRACTOR IS RESPONSIBLE FOR VERIFYING CEILING
HEIGHTS PRIOR TO INSTALLATION. WHERE THIS METHOD IS USED A MINIMUM CLEARANCE OF 80" ABOVE THE
FINISHED FLOOR MUST BE MAINTAINED. THREAD ROD IS TO BE SCREWED DIRECTLY INTO THE CEILING OR
FASTENED TO ACOUSTICAL CEILING GIRD WITH A GRID CLIP
F. FLAG MOUNT – WALL MOUNTED FLAG MUST BE INSTALLED WITH A MINIMUM CLEARANCE OF 80” ABOVE THE
FINISHED FLOOR.
G. MONUMENTAL WITH CONCRETE FOUNDATION (EXTERIOR)
H. POLE MOUNT - SIGN TO BE SECURED ON EXISTING EXTERIOR LAMP POSTS WITHIN THE PARKING LOTS.
Total Building 13 Signage = 148
Primary – IN-04.01 29
Secondary – IN-04.02 6
BOH – IN-03.01 12
Exam/Conference – IN-07.05 18
Inpatient Single – IN-05.07 0
Inpatient Double – IN-05.08 0
Stairs IN-01.10 8
Stairs IN-01.11 6
Elevator IN-09.08 3
Restroom – IN-09.01, 02, 03 6
Baby Changing – IN-09.08 4
Notice – IN-10.01 6
Guide 4 Line – IN-15.62 0
Guide 2 Line – IN-15.56 0
Guide 1 Line – Ceiling – IN-15.55 6
Guide 1 Line – Wall – IN-16.51 0
Guide Small Wall – IN-14.15 2
Guide Med. Wall – IN-14.16 13
Guide Large Wall – IN-14.18 0
Guide Floor Info – IN-11.01 5
Guide Flag – IN-13.01 20
Guide Map – IN-17.00 0
Directory – IN-17.05 4
Building Exterior – EN-06.04A 0
INSTRUCTIONS FOR READING THESE DOCUMENTS:
Match the sign number indicated in each tag in the drawings to the sign number located in the schedules to identify the designated name, department, sign type, and mounting type. Typical elevations of each sign type can be found in the general sheets for visual reference.
OWNER
VA HINES MEDICAL CENTER
CONTACT: Jake Kanuru
Project Planning COR 5000 S. Fifth Avenue Building 2 Hines, IL 60141 p: 708-202-8387 x 21149 e: Jake.Kanuru@va.gov
ARCHITECT
GUIDON DESIGN
CONTACT: Luke Leising
Project Manager 1221 North Pennsylvania Street Suite 200 Indianapolis, IN 46202 p: 317.800.6388 e: luke@guidondesign.com
BUILDING 13
SIGN ID
ROOM
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
0001 B04A MECHANICAL Engineering IN-03.01 A
0002 B02 ELEVATOR MACHINE ROOM Engineering IN-03.01 A
0003 B04B MECHANICAL Engineering IN-03.01 A
0004 IG1
BASEMENT <N/L>
(RIGHT) UTILITY TUNNEL <N/L>
(LEFT) ENGINEERING IN-14.16 A
0005 B10 UTILITY TUNNEL Engineering IN-03.01 A
0006 B06 STAIRS N/A IN-01.10 A
0007 IG26 STAIRS Mental Health IN-13.01 F
0008 B10 FIRE PUMP ROOM Engineering IN-03.01 A
0009 B07 ELECTRICAL Engineering IN-03.01 A
0020 D12 (FRONT) TO BUILDING 13 (BACK) TO BUILDING 12 N/A IN-15.55 E
0021 105
WEST STAIRS <N/L>
NO ROOF ACCESS <N/L>
FLOOR 1 <N/L>
1 THROUGH 3 EXIT LEVEL 1 N/A IN-01.11 A
0022 105 WEST STAIRS N/A IN-01.10 A
0022-A 105 WEST STAIRS N/A IN-13.01 F
0023 106 TELECOMMUNICATIONS OI&T IN-03.01 A
0024 D13 BUILDING 13 N/A IN-15.55 A
0025 IG2
FLOOR 1 <N/L>
(LEFT) ELEVATORS <N/L>
(LEFT) FIRST-FLOOR LOBBY <N/L>
(LEFT) PRRC CLASSROOMS <N/L>
(LEFT) RESTROOM N/A IN-14.16 A
0026 IG16
DIRECTORY <N/L>
PRRC .... Floor 1 <N/L>
MHICM …. Floor 2 <N/L>
CWT …. Floor 3 Mental Health IN-17.05 A
0027 IG3 (LEFT) BUILDING 12 N/A IN-13.01 F
0028 104 CLASSROOM Mental Health IN-07.05 A
0029 109 CLASSROOM Mental Health IN-07.05 A
0030 IG4 (LEFT) TO BUILDING 12 N/A IN-13.01 F
0031 IG6 (RIGHT) TO BUILDING 12 N/A IN-15.55 E
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
BASEMENT
FIRST FLOOR
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
Not used
Building 13 Signage Legend Page 1 of 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0033 103 CLASSROOM Mental Health IN-07.05 A
0034 102 ELEVATOR N/A IN-09.08 A
0035 104C
FLOOR 1 <N/L>
(RIGHT) MENTAL HEALTH RECEPTION <N/L>
(RIGHT) RESTROOM <N/L>
(LEFT) MENTAL HEALTH GROUP ROOMS N/A IN-14.16 A
0036 104C ELEVATOR N/A IN-13.01 F
0036A
FLOOR 1 <N/L>
BUILDING 13 N/A IN-11.01 A
0036B
DIRECTORY <N/L>
PRRC .... Floor 1 <N/L>
MHICM …. Floor 2 <N/L>
CWT …. Floor 3 N/A IN-17.05 A
0037 110A ELECTRICAL Engineering IN-03.01 A
0038 IG9
FLOOR 1 <N/L>
(STRAIGHT) ELEVATOR
(STRAIGHT) PRRC CLASS ROOMS
(STRAIGHT) WINTER GARDEN
(STRAIGHT) BUILDING 12 N/A IN-14.16 A
0039 101 STORAGE Mental Health IN-04.02 A
0040 N/A N/A N/A N/A DEMO
0041 110
DIRECTORY <N/L>
PRRC .... Floor 1 <N/L>
MHICM …. Floor 2 <N/L>
CWT …. Floor 3 N/A IN-14.16 A Keep, and update with new.
0042 111 WOMEN IN-09.02 A
0043 100 RECEPTION Mental Health IN-13.01 F
0044 IG12
(LEFT FACING PLAN EAST) BUILDING 200 MAIN
HOSPITAL, BUILDING 228 MENTAL HEALTH
(SRAIGHT FACING PLAN WEST) BUILDING 12 N/A IN-15.55 E
0045 100A H.A.C Environmental Management Services (EMS) IN-04.02 A
0046 114 MEN IN-09.01 A
0047 110 N/A N/A N/A N/A DEMO
0048 126 RESOURCE ROOM Mental Health IN-07.05 A
0049 IG14
FIRST FLOOR<N/L>
(STRAIGHT) PRRC OFFICE <N/L>
(STRAIGHT) PRRC FAMILY ROOM N/A IN-14.16 A
0050 124B H.A.C Environmental Management Services (EMS) IN-04.02 A
0051 115 OFFICE Mental Health IN-04.01 A
Building 13 Signage Legend Page 2 of 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0052 125 STAFF LOUNGE Mental Health IN-07.05 A
0053 116 OFFICE Mental Health IN-04.01 A
0054 117 OFFICE Mental Health IN-04.01 A
0055 118 OFFICE Mental Health IN-04.01 A
0056 123A FAMILY ROOM Mental Health IN-04.01 A
0057 123B STAFF LOUNGE Mental Health IN-07.05 A
0058 119 OFFICE Mental Health IN-04.01 A
0059 120A MULTIPURPOSE Mental Health IN-07.05 A
0060 120B MULTIPURPOSE Mental Health IN-07.05 A
0061 105C EAST STAIRS Mental Health IN-13.01 F
0062 122 EAST STAIRS N/A IN-01.10 A
0063 122
EAST STAIRS <N/L>
NO ROOF ACCESS <N/L>
FLOOR 1 <N/L>
1 THROUGH 3 EXIT LEVEL 1 N/A IN-01.11 A
0070 216
FLOOR 2
(RIGHT) MAIN ELEVATORS <N/L>
(RIGHT) CLINIC WAITING <N/L>
(RIGHT) RESTROOM Mental Health IN-14.16 A
0071 206 STAIRS N/A IN-01.10 A
0071-A 206 STAIRS N/A IN-13.01 F
0072 206
STAIRS <N/L>
NO ROOF ACCESS <N/L>
FLOOR 2 <N/L>
1 THROUGH 3 EXIT LEVEL 1 IN-01.11 A
0073 205 TELECOMMUNICATIONS OI&T IN-03.01 A
0074 207 GROUP ROOM Mental Health IN-07.05 A
0075 208 GROUP ROOM Mental Health IN-07.05 A
0076 208 GROUP ROOM Mental Health IN-07.05 A
0077 204 GROUP ROOM Mental Health IN-07.05 A
0078 203 OFFICE Mental Health IN-04.01 A
0079 209 GROUP ROOM Mental Health IN-07.05 A
SECOND FLOOR
Building 13 Signage Legend Page 3 of 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0080 202
DIRECTORY <N/L>
PRRC .... Floor 1 <N/L>
MHICM …. Floor 2 <N/L>
CWT …. Floor 3 N/A IN-17.05 A
0081 209 ELEVATOR N/A IN-13.01 F
0082 211 OFFICE Mental Health IN-04.01 A
0082A
FLOOR 2 <N/L>
BUILDING 13 N/A IN-11.01 A
0083 202 ELEVATOR N/A IN-09.08 A
0084 201 CONFERENCE ROOM Mental Health IN-07.05 A
0085 214 N/A N/A N/A N/A DEMO
0086 214A ELECTRICAL Engineering IN-03.01 A
0087 212 WOMEN IN-09.02 A
0087-A 212 WOMEN IN-13.01 F
0088 200
FLOOR 2 <N/L>
(RIGHT) WAITING ROOM Mental Health IN-14.15 A
0088-A 200 WAITING ROOM Mental Health IN-13.01 F
0089 214 N/A N/A N/A N/A DEMO
0090 213 STAIRS N/A IN-01.10 A
0090-A 213 STAIRS N/A IN-13.01 F
0091 214B H.A.C Environmental Management Services (EMS) IN-04.02 A
0092 225 OFFICE Mental Health IN-04.01 A
0093 IG19
FLOOR 2 <N/L>
(STRAIGHT) MHICM <N/L>
(STRAIGHT) ROOMS 217-224 N/A IN-14.16 A
0094 215 MEN IN-09.01 A
0094-A 215 MEN IN-13.01 F
0095 224 STAFF LOUNGE Mental Health IN-07.05 A
0096 217 OFFICE Mental Health IN-04.01 A
0097 222 OFFICE Mental Health IN-04.01 A
0098 221 OFFICE Mental Health IN-04.01 A
0100 220 EAST STAIRS N/A IN-01.10 A
0100-A 220
EAST STAIRS <N/L>
NO ROOF ACCESS <N/L>
FLOOR 2 <N/L>
1 THROUGH 3 EXIT LEVEL 1 N/A IN-01.11 A
0101 IG24 EAST STAIRS N/A IN-13.01 F
Building 13 Signage Legend Page 4 of 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0111 308
WEST STAIRS <N/L>
NO ROOF ACCESS <N/L>
FLOOR 3 <N/L>
1 THROUGH 3 EXIT LEVEL 1 N/A IN-01.11 A
0112 308 STAIRS N/A IN-01.10 A
0112-A 308 STAIRS N/A IN-13.01 F
0113 307 TELECOMMUNICATIONS OI&T IN-03.01 A
0114 316
FLOOR 3 <N/L>
(RIGHT) CWT ROOMS<N/L>
(RIGHT) WAITING ROOM <N/L>
(RIGHT) RESTROOM <N/L>
(RIGHT) ELEVATOR Mental Health IN-14.16 A
0115 309 OFFICE Mental Health IN-04.01 A
0116 310 OFFICE Mental Health IN-04.01 A
0117 306 CONFERENCE ROOM Mental Health IN-07.05 A
0118 309C
FLOOR 3 <N/L>
(RIGHT) CWT ROOM 306 <N/L>
(LEFT) CWT ROOM 305 <N/L>
(LEFT) CWT ROOMS 307-332 <N/L>
(LEFT) ELEVATOR <N/L>
(LEFT) RESTROOM Mental Health IN-14.16 A
0119 305 CLASSROOM Mental Health IN-07.05 A
0120 316
FLOOR 3 <N/L>
(RIGHT) CWT ROOMS 317-332 <N/L>
(RIGHT) ELEVATOR <N/L>
(RIGHT) RESTROOM Mental Health IN-14.16 A
0121 311
FLOOR 3 <N/L>
(STRAIGHT) CWT ROOMS 317-332 <N/L>
(LEFT) CWT ROOMS 305-306 <N/L> N/A IN-14.16 A
Keep, and update with new.
0121A 202 ELEVATOR N/A IN-09.08 A
0121B 202 ELEVATOR N/A IN-13.01 F
0121C
DIRECTORY <N/L>
PRRC .... Floor 1 <N/L>
MHICM …. Floor 2 <N/L>
CWT …. Floor 3 N/A IN-17.05 A
THIRD FLOOR
Building 13 Signage Legend Page 5 of 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0121D
FLOOR 3 <N/L>
BUILDING 13 N/A IN-11.01 A
0122 303 OFFICE Mental Health IN-04.01 A
0123 300A ELECTRICAL Engineering IN-03.01 A
0124 312 WOMEN IN-09.02 A
0124A 312 WOMEN IN-13.01 F
0125 IG22 N/A N/A N/A N/A DEMO
0125-A IG22
THIRD FLOOR
(STRAIGHT) Elevator
(STRAIGHT) CWT Group Rooms 305, 306 N/A IN-14.16 A
0126 302 STAFF LOUNGE Mental Health IN-07.05 A
0127 IG29 WAITING ROOM MENTAL HEALTH IN-13.01 F
0128 IG23 N/A N/A N/A N/A DEMO
0129 332 OFFICE Mental Health IN-04.01 A
0130 300B H.A.C Environmental Management Services (EMS) IN-04.02 A
0131 315 MEN IN-09.01 A
0131A 315-A MEN IN-13.01 F
0132 IG25
FLOOR 3 <N/L>
(STRAIGHT) CWT ROOMS 317-330 N/A IN-14.15 A
0133 301 CWT CHECK IN N/A IN-15.55 E
0134 331 OFFICE Mental Health IN-04.01 A
0135 329 FILE ROOM STORAGE Mental Health IN-04.02 A
0136 330 OFFICE Mental Health IN-04.01 A
0137 317 OFFICE Mental Health IN-04.01 A
0138 318 OFFICE Mental Health IN-04.01 A
0139 328B OFFICE Mental Health IN-04.01 A
0140 328A OFFICE Mental Health IN-04.01 A
0141 319 OFFICE Mental Health IN-04.01 A
0142 320 OFFICE Mental Health IN-04.01 A
0143 327 OFFICE Mental Health IN-04.01 A
0144 326 OFFICE Mental Health IN-04.01 A
0145 321 OFFICE Mental Health IN-04.01 A
0146 322 OFFICE Mental Health IN-04.01 A
0147 323 OFFICE Mental Health IN-04.01 A
0148 IG31
FLOOR 3 <N/L>
BUILDING 13 Mental Health IN-11.01 A
Building 13 Signage Legend Page 6 of 7
NUMBER
NEW SIGN TEXT NEW SIGN DEPARTMENT SIGN TYPE ID
MOUNTING
TYPE
COMMENTS
BUILDING 13 SIGNAGE LEGEND
VA HINES MEDICAL CAMPUS
Legend is sorted by sign ID. Refer to signage drawing to locate each sign ID according to sequential order of rooms.
0149 325 STAIRS N/A IN-01.10 A
0150 325
STAIRS <N/L>
NO ROOF ACCESS <N/L>
FLOOR 3 <N/L>
1 THROUGH 3 EXIT LEVEL 1 N/A IN-01.11 A
0151 D2 CWT CHECK IN Mental Health IN-15.55 E
0152 IG32
FLOOR 3 <N/L>
BUILDING 13 N/A IN-11.01 A
0153 IG33 STAIRS N/A IN-13.01 F
Building 13 Signage Legend Page 7 of 7
File details come from the government source that posted it. Updated .