7-Attachmetn B - Fire Station 23 Rev. 08.19.26.pdf

PDF 3 MB Posted

Attached to
GJ27-18 North Summit Fire District Fire Station 23 Dorm Addition and Interior Remodel
Solicitation number
GJ27-18
Issued by
Summit County, Utah

About this file

This is a design and construction document set for Fire Station 23, an interior remodel and dorm addition project managed by the North Summit Fire District in Wanship, Utah (located in Summit County). The project involves a 1,850 square-foot interior remodel and the addition of three new sleeping rooms at the existing fire station located at 2000 South Hoytsville Road, Coalville, Utah 84017. Additional work includes upgrading lighting systems, replacing mechanical units, and general facility improvements to meet current building codes. The mandatory pre-proposal site visit is scheduled for August 27, 2026, with questions due by September 2, 2026 at 2:00 PM Mountain Time, and bid submissions due by September 4, 2026 at noon Mountain Time via the U3P portal. The project is designed to comply with the 2021 International Building Code, 2021 International Plumbing Code, 2021 International Mechanical Code, 2021 International Fire Code, 2020 National Electrical Code, 2021 International Energy Conservation Code, and ADA requirements.

The construction documents indicate the facility will be classified as Type IIB construction with an occupancy classification of B (administrative), S-2 (vehicles bay and storage), and R-2 (sleeping quarters). The building has an allowable height of 40 feet with a current height of 1 story. The remodel scope includes removal and replacement of plumbing fixtures, installation of new shower pans with FRP wall finishes, removal and upgrading of lighting fixtures throughout sleeping areas and common spaces, new HVAC mechanical units, removal of existing siding with installation of new hardboard siding and trim, replacement of overhead doors and window systems, and interior wall modifications to accommodate the new sleeping rooms. Specific document references include architectural plans (A101-A501), mechanical and plumbing plans (M201, P201), and electrical plans (E000-E601). The design team includes Alt Architecture as the architect, JTB Engineering for mechanical systems, and Rocky Mountain Consulting Engineers for electrical systems.

View the file

Other files

File Type Posted
3-Attachment C Cost Sheet.xlsx XLSX spreadsheet
9-20250120 111534.jpg JPG image
4-Attachment E.pdf PDF
12-Award Justification.pdf PDF
8-25042 - Wanship Fire Station 23 - ADD3.pdf PDF
6-Attachment A Standard Terms and Conditions GOODS AND SERVICES.docx DOCX document
5-Attachment B2 - Westnet plans.pdf PDF
2-Staiton 23 RFP.pdf PDF
1-Attachment D Technical Evaluation Scoring Sheet.xlsx XLSX spreadsheet
10-Pre-proposal Mtg Attendance Log ADA (1).docx DOCX document
11-000 U3P Courtesy Posting Closed.pdf PDF
Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT LOCATION

NOTES TO BIDDERS:

1. FURNITURE ARE FOR REFERENCE ONLY AND WILL BE OWNER

PROVIDED.

2. CONTRACTOR, SUBCONTRACTOR, VENDOR OR ANY OTHER

PERSON PARTICIPATING IN BIDDING THIS PROJECT SHALL BE

RESPONSIBLE FOR INFORMATION CONTAINED IN ANY AND ALL

SHEETS OF DRAWINGS AND SPECIFICATIONS.

JURISDICTION

SUMMIT COUNTY, UTAH

CODE

2021 INTERNATIONAL BUILDING CODE (IBC)

2021 INTERNATIONAL PLUMBING CODE (IPC)

2021 INTERNATIONAL MECHANICAL CODE (IMC)

2021 INTERNATIONAL FIRE CODE (IFC)

2020 NATIONAL ELECTRICAL CODE (NEC)

2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)

2017 AMERICANS WITH DISABILITIES ACT (ADA) (ANSI A117.1)

OCCUPANCY (CH. 3)

OCCUPANCY: B ADMINISTRATIVE

S-2 VEHICLES BAY & STORAGE

R-2 SLEEPING QUARTERS

A ASSEMBLY (UNDER 100)

REQUIRED SEPARATION OF OCCUPANCIES (508.4)

NONE

TYPE OF CONSTRUCTION

IA IB IIA IIB IIIA IIIB IVA IVB VA VB

AUTOMATIC SPRINKLER SYSTEM

YES NO

BUILDING HEIGHT (504.3)

ALLOWABLE BUILDING HEIGHT ALLOWED ACTUAL

40'-0" EXISTING

NUMBER OF STORIES (504.4)

ALLOWABLE NUMBER OF STORIES 2 1

BUILDING AREA (506)

REMODEL 9,000 SF 1,850 SF

FIRE RESISTIVE REQUIREMENTS FOR IIB (TABLE 601)

PRIMARY STRUCTURAL FRAME 0 HR RATING

BEARING WALLS

EXTERIOR 0HR RATING

INTERIOR 0HR RATING

NON BEARING WALLS 0HR RATING

FLOOR CONSTRUCTION 0HR RATING

ROOF CONSTRUCTION 0HR RATING

EGRESS WIDTH (TABLE 1005.1)

OTHER EGRESS 0.2 INCHES PER OCCUPANT

PLUMBING FIXTURES

EXISTING WATER CLOSETS 2

EXISTING LAVATORIES 2

DRINKING FOUNTAINS 0

SERVICE SINKS 1

FIRE STATION 23 alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

DESIGN TEAM

OWNER

HENEFER FIRE STATION 22

TYLER ROWSER, ADMINISTRATIVE BATTALION CHIEF

ARCHITECT

alt architecture

1445 WEST 8660 SOUTH

WEST JORDAN, UTAH 84088

801-865-0633 andy@altarchitecture-ut.com

ANDY TONGISH, AIA

MECHANICAL

JTB ENGINEERING

922 W. BAXTER DRIVE, SUITE 100

SOUTH JORDAN, UTAH 84121

801-849-8590 jeff.brown@jtbengineering.net

JEFF BROWN, PE

ELECTRICAL

ROCKY MOUNTAIN CONSULTING ENGINEERS

2332 WEST 12600 SOUTH SUITE F

RIVERTON, UTAH 84065

801-566-0503 david@rmceut.com

DAVID STEWARD, PE

VICINITY MAPDRAWING INDEX

RENDERING

PROJECT SUMMARY

2000 SOUTH HOYTSVILLE ROAD COALVILLE, UTAH 84017

NORTH SUMMIT FIRE DISTRICT

CODE ANALYSIS

/1

/2

:3

:4

A M

C O

V

ER

S H

EE

T

25-001 act act

8/19/2026

COVER

SHEET

G001

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

DRAWING INDEX

SHEET # SHEET CONTENTS

GENERAL

G001 COVER SHEET

ARCHITECTURAL

A101 FLOOR PLAN

A102 REFLECTED CEILING PLAN & MISC.

A201 EXTERIOR ELEVATIONS

A401 INTERIOR ELEVATIONS

A501 MISC. DETAILS

SP1 SPECIFICATIONS

MECHANICAL

M001 TITLE SHEET (LEGEND & ABBREVIATIONS)

M201 MECHANICAL PLANS

P201 PLUMBING PLAN

ELECTRICAL

E000 ELECTRICAL GENERAL SHEET

E101 LIGHTING PLAN

E201 POWER PLAN

E601 ELECTRICAL SCHEDULES

8/19/2026

INTERIOR REMODEL ADDING 3 SLEEP ROOMS, UPGRADE LIGHTING, AND

MECHANICAL UNITS.

N

BENJAMIN NIELSON - FIRE CHIEF DATE

TYLER ROWSER - ADMINISTRATIVE BATTALION CHIEF DATE

8/14/2025 FOR BIDDING

4/27/2026 MOVED PATIO

TO WEST SIDE

8/19/2026 OWNER REVIEW

CHANGES

WD

REF.REF.

A201

/8

/4

/4

/8

EX

EX

REMOVE CARPET & PAD, &

BASE TO CONCRETE

THROUGHOUT THE

BUILDING. REMOVE GLUE.

A102

EX

W1

W1

W1

W1

W1

W1

F1

B1C1 W1W1

W1

W1

F1

B1C1 W1W1

W1

W1

F1

B1C1 W1W1

W1

F1

B1C1 W1

NO WORK IN THIS AREA

F2

B3C1 W1

EX

1/ A4

A201

EXISTING

ELECTRICAL PANEL

A201

A201

A

A

A

11' - 10"

W1

T

EXISTING ELECTRICAL PANEL

4/A401

A401

TYP

W1

W1

W1

SLEEPING 1

SLEEPING 2

SLEEPING 3

W1

F1

B1C1 W1W1

W1

OFFICE/SLEEPING 4

MECHANICAL

STORAGE

KITCHEN

RESTROOM

RESTROOM

EQUIPMENT BAY

WINDOW INFILL

SEE WALL TYPE W2

GROUP ROOM

8/A401

9/ A4

SHOWER SHOWER

13 13

4" CONCRETE STEP

@ FLOOR LEVEL

4" CONCRETE SLAB

ON 4" GRAVEL BASE @

GRADE - LEVEL w/

LANDSCAPING

NOTE:

PATCH & REPAIR LANDSCAPING

AROUND NEW CONCRETE PAD

SL

O

P E

SLOPE

/8

1' - 0"

5' - 6"

17' - 0"

SLOPE

W1

W1

W1

PARKING STRIPPING LAYOUT TO BE PROVIDED

BY OWNER, INSTALLED BY CONTRACTOR

3/ A4

12/A401

/A

13/A401

10/A401

4' - 0"

8' - 0"

EXISTING HOSE CONNECTION

EXISTING HOSE CONNECTION

R1

R1

R1

R1

R1

STACKED W & D

HOSE BIBB - TAP OFF

HOSE CONNECTION

PIPE

HOSE BIBB - TAP OFF HOSE

CONNECTION PIPE

REPLACE EXISTING PIPING

INTERIOR ELEVATIONS SIM.

4' - 0"

F2

B1C1 W1

W1

W1

W1

3 1

EX

EXTEND 4'-0" x 4'-0" DIAMOND PLATE

BEHIND FAUCET & HOSE CONNECTION

EXTEND 4'-0" x 4'-0" DIAMOND PLATE

BEHIND FAUCET & HOSE CONNECTION

PROVIDE PLASTIC HDPE BOLLARD

COVER OVER EXISTING STEEL

BOLLARD; COLOR TBD.

PROVIDE PLASTIC HDPE BOLLARD

COVER OVER EXISTING STEEL

BOLLARD; COLOR TBD.

PROVIDE PLASTIC HDPE BOLLARD

COVER OVER EXISTING STEEL

BOLLARD; COLOR TBD.

R1

KEYED NOTES

1 OWNER SHALL REMOVE ALL WALL ITEMS TO BE SAVED. THE CONTRACTOR

SHALL REMOVE ALL REMAINING ITEMS & PROPERLY DISPOSE OF ITEMS.

2 REMOVE WOOD TRIM IN SLEEPING QUARTERS, PATCH & REPAIR WALL

BEFORE PAINTING.

3 PATCH & REPAIR WALL AFTER DEMOLITION.

4 REMOVE EXISTING WINDOW SYSTEM, INFILL OPENING w/ MATCHING

THICKNESS MATERIAL.

5 REMOVE PORTION OF NON-BEARING WALL FOR NEW WINDOW SYSTEM.

6 REMOVE EXISTING WALL, DOOR & FRAME.

7 REMOVE EXISTING DOOR & FRAME. PATCH WALL w/ MATCHING THICKNESS

METAL STUDS & 5/8" TYPE 'X' GYPSUM BOARD EACH SIDE.

8 REMOVE EXISTING FOLDING PARTITION DOOR & FRAME, PATCH & REPAIR

WALL & CEILING

9 REMOVE EXISTING LIGHTS IN SLEEPING AREAS, KITCHEN, RESTROOMS &

GROUP ROOM, REFER TO REFLECTED CEILING PLAN & ELECTRICAL DWGS.

10 REMOVE EXISTING DRINKING FOUNTAIN PIPING, CAP PIPES BEHIND WALL.

PATCH & REPAIR GYPSUM BOARD IN THIS AREA.

11 EXISTING CEILING ACCESS TO REMAIN.

12 REMOVE FRP WALL FINISHES, SHOWER PAN AND PLUMBING FIXTURES.

INSTALL NEW SHOWER PAN, MATCHING DRAIN LOCATION, & FRP WALL

FINISH TO 8'-0".

13 REMOVE EXISTING PLUMBING FIXTURES. INSTALL NEW TOILET, & NEW SINK.

PROVIDE NEW PIPING AS NEEDED.

14 INSTALL NEW 1x4 SURFACE MOUNTED LED FIXTURE.

15 REMOVE COILING DOOR, FRAME, & HARDWARE.

16 PATCH & REPAIR DAMAGED CEILING.

17 ADJUSTABLE SHELVING: (5) 1" MELAMINE SHELVES, ROUNDED FRONT EDGE,

WALL BRACKET & SHELF SUPPORTS

TYPE

W1

FIRE RATING

FIRE TEST

HEIGHT

NONE

NONE

TO DECK ABOVE

INTERIOR FACE: 5/8" GYPSUM

BOARD

STRUCTURE: 2x4 WOOD STUD @ 16" oc

INTERIOR FACE: 5/8" GYPSUM

BOARD

TYPE

W2

FIRE RATING

FIRE TEST

HEIGHT

NONE

NONE

VERIFY OPENING

INTERIOR FACE: 5/8" GYPSUM

BOARD, ALIGN w/ EXISTING WALL

STRUCTURE: MATCH EXISTING

WALL THICKNESS

EXTERIOR: EIFS ON WEATHER

BARRIER ON SHEATHING

INSULATION: MATCH EXISTING

WALL THICKNESS - R19 MIN.

INSULATION: R13 BATT SOUND

INSULATION

GENERAL NOTES:

1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE. LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER

SMALLER SCALE DRAWINGS. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DIMENSION DISCREPANCIES OR

CONFLICTS BEFORE PROCEEDING WITH THAT PORTION OF WORK.

2. CONTRACTOR SHALL VERIFY LAY-OUT OF STRUCTURAL, MECHANICAL, AND ELECTRICAL.

3. ALL INTERIOR DIMENSIONS ARE TO/FROM FACE OF STUD / MASONRY. ALL EXTERIOR DIMENSIONS ARE TO/FROM FACE OF

GRID/FOUNDATION. DIMENSIONS MARKED 'CLEAR' OR 'CLR' ARE FROM FACE OF FINISH TO FACE OF FINISH AND SHALL BE MAINTAINED AND

CANNOT BE FIELD ADJUSTED WITHOUT PRIOR APPROVAL OF THE ARCHITECT.

4. ALL DOOR FRAMES SHALL BE 3" MIN. FROM WALL U.N.O.

5. BLOCKING TO BE PROVIDED FOR ALL WALL MOUNTED EQUIPMENT

6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION IN THE

DOCUMENTS. THE GENERAL CONTRACTOR SHALL UTILIZE THE COMPLETE & ENTIRE CONSTRUCTION DRAWINGS AND WRITTEN

SPECIFICATIONS FOR ALL REQUIRED INFORMATION TO PROVIDE COMPLETE CONSTRUCTION OF THIS PROJECT AND IS RESPONSIBLE TO

COORDINATE ALL DRAWINGS AND SPECIFICATIONS WITH ALL SUBCONTRACTORS REGARDLESS OF LOCATION IN CONTRACT DOCUMENTS.

ITEMS LISTED IN DRAWINGS MAY NOT BE INCLUDED IN SPECIFICATIONS. ITEMS LISTED IN SPECIFICATIONS MAY NOT BE INCLUDED IN

DRAWINGS.

7. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING ANY WORK.

8. THE GENERAL CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT ANY DISCREPANCIES DURING BIDDING AND PRIOR TO COMMENCING

WORK.

9. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA

SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.

10. CONSTRUCTION SHALL CONFORM WITH ANSI A-117.1-2009, AND THE AMERICANS WITH DISABILITIES ACT (ADA).

11. THE GENERAL CONTRACTOR SHALL PROVIDE AND IS SOLELY RESPONSIBLE AND LIABLE FOR PUBLIC AND EMPLOYEE PROTECTION AS

NECESSARY AND AS REQUIRED BY THE CODES, INCLUDING EXTERIOR AND INTERIOR PEDESTRIAN TRAFFIC BARRIERS. ALL WORK SHALL

CONFORM TO THE ORDINANCES AND REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT.

12. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADES FOR DUST AND NOISE CONTROL, AND ALL REQUIRED

ENVIRONMENTAL PROTECTION WHERE WORK JOINS EXISTING CONDITIONS.

13. ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED WITH APPROPRIATE SEALANT MATERIAL.

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

/1

/2

:3

:4

A M

FL

O

O R

P

LA

N

25-001 act act

8/19/2026

FLOOR PLAN

A101

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

1/4" = 1'-0"A101

1 FLOOR PLAN

PROJECT NORTH

N

TRUE NORTH

DOOR SCHEDULE

MARK

LEAF SIZE

DOOR TYPE THICKNESS CONST. FINISH GLASS RATING

FRAME

TYPE

HARDWARE

GROUP KEYNOTEW H

1 3' - 0" 7' - 0" WD01 1 3/4" STAIN N N A -

2 3' - 0" 7' - 0" HM01 1 3/4" PAINT Y 45 EX -

3 3' - 0" 7' - 0" HM02 1 7/8" PAINT N 45 A

4 3' - 0" 7' - 0" AL01 1 3/4" - Y N

5 10' - 0" 12' - 0" AL04 1 1/2" STEEL Y N - - SEE NOTE CONCERNING

OH DOORS

EX 3' - 0" 7' - 0" <varies> 1 3/4" PAINT N <varies> <varies>

8/19/2026

N

8' - 0"

8' - 0"

8' - 0"

EXISTING FASCIA & SOFFIT

ALL NEW WALLS TO

EXTEND TO EXISTING

CEILING GYPSUM BOARD

PATCH & REPAIR GYPSUM

BOARD CEILING AFTER WALL

DEMOLITION

3' - 0"

3' - 0"

NOTE:

LIGHT LAYOUT IS TYPICAL

EACH SLEEPING ROOM

EXISTING VENTS

DEMOLITION NOTE

CONTRACTOR SHALL REMOVE LIGHT

FIXTURE IN SLEEP/OFFICE, RESTROOMS,

KITCHEN, & GROUP ROOM. REPLACE w/

NEW FIXTURES PER ELECTRICAL

DRAWINGS.

EXISTING FASCIA & SOFFIT

EXISTING FASCIA & SOFFIT

SEE A101 FOR KEYED NOTES

SLEEPING 1

SLEEPING 2

SLEEPING 3

DOWNLIGHTS - TYP

F.V.

F.V.

F.V.

REFER TO ELECTRICAL PLANS FOR LIGHTING LAYOUT

NOTE:

2x @ 16" o.c. EXT. WALL. GC TO VERIFY

SHEATHING IS NAILED TO STUDS AT 6"

O.C. EDGE AND 12" O.C. FIELD AFTER

SIDING IS REMOVED & WHERE

POSSIBLE.

". (E) ANCHOR BOLTS TO BE 1/2" DIA.

(MIN.), SPACED NO FURTHER THAN 6'-0"

APART (PER IBC 2308.3.1). NOTIFY EOR

IF OTHERWISE"

(2) 2x6 HEADER w/ (2) STUDS

BOTH SIDES (1) JACK, (1) KING

(2) 2x6 HEADER w/ (2) STUDS

BOTH SIDES (1) JACK, (1) KING

(2) 2x6 HEADER w/ (2) STUDS

BOTH SIDES (1) JACK, (1) KING

A501

BASE

W1 @ 16" oc w/ 5/8" GYP. BD.

EACH SIDE w/ 3 1/2" THICK

SOUND INSULATION

TYP.

EXISTING

CEILING

SLEEPING

GROUP ROOM

WOOD DOOR

HM FRAME

PROVIDE BLOCKING AS

NEEDED FOR WALL SUPPORT

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

/1

/2

:3

:4

A M

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

M

IS

C

25-001 act act

8/19/2026

REFLECTED

CEILING PLAN &

MISC.

A102

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

1/4" = 1'-0"A102

1 REFLECTED CEILING PLAN

1/8" = 1'-0"A102

2 STRUCTURAL PAN

3/8" = 1'-0"A102

3 SECTION

FLOOR PLAN

100' - 0"

EXISTING SOFFIT & FASCIA

NEW ALUMINUM WINDOW SYSTEM

EXISTING GAS METER

EXISTING ELECTRICAL EQUIPMENT

MATCH EXISTING VENT

ALUMINUM

STOREFRONT DOOR

SYSTEM

IN-FILLED WINDOW LOCATION

MATCH EXISTING VENT

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

FLOOR PLAN

100' - 0"

EXISTING WINDOW SYSTEM

EXISTING SOFFIT & FASCIA

EXISTING HM DOOR & FRAME

PAINT

A501

TYP

REMOVE EXISTING SIGNAGE

NEW SIGNAGE INSTALLED BY OWNER

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

FLOOR PLAN

100' - 0"

EXISTING WINDOW SYSTEM

EXISTING SOFFIT & FASCIA

A501

IN-FILL WINDOW LOCATION

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

FLOOR PLAN

100' - 0"

EXISTING SOFFIT & FASCIA

EXISTING OVERHEAD DOORS TO BE REMOVED

INSTALL NEW OH DOORS & SYSTEM

MATCH EXISTING VENT

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING & TRIM

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

/1

/2

:3

:4

A M

EX

TE

R

IO

R E

LE

V

A

TI

O N

S

25-001 act act

8/19/2026

EXTERIOR

ELEVATIONS

A201

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

1/4" = 1'-0"A201

1 NORTH ELEVATION

1/4" = 1'-0"A201

3 EAST ELEVATION

1/4" = 1'-0"A201

4 WEST ELEVATION

1/4" = 1'-0"A201

2 SOUTH ELEVATION

IN-FILLED DOOR OPENING

16 ga. DIAMOND PLATE

PAINTABLE - TYP. ALL 4 WALLS

EXISTING ELECTRICAL PANEL

EXISTING ELECTRICAL PANEL

REMOVE MOUNTED ITEMS

COVED EPOXY BASE

A401

A401

A401

OFFICE/SLEEPING 4 = 5'-6" F.V.

2'-9" F.V. 3' - 0" 3' - 0" 3' - 0"

SCHEDULED CEILING

PLASTIC LAMINATE

CASEWORK

BASE

CLEAT - PAINT

1" MELAMINE

ADJUSTABLE SHELVING

PROVIDE SUPPORTS AS

NEEDED

EXISTING CEILING

UPGRADED LIGHT FIXTURE

BASE - BY OWNER

SCHEDULED WALL

4" SS HANDLE

PLASTIC LAMINATE DOOR

MELAMINE INTERIOR

(4) 3/4" MELAMINE SHELF

(ADJUSTABLE)

2x4 BASE

3/4" MELAMINE SHELF

(FIXED)

1" DIVIDER - FULL HEIGHT

KEY LOCK EACH DOOR

1' - 10"

1'

- 7

4" SS HANDLE

PLASTIC LAMINATE DOOR

MELAMINE INTERIOR

3/4" MELAMINE SHELF

(FIXED)

2x4 BASE

1" ROD

3/4" MELAMINE SHELF

(FIXED)

KEY LOCK EACH DOOR

1'

- 7

1' - 10"

LINE OF CASEWORK BEYOND

3/16" x 1" BRACKET

PAINT

PLASTIC LAMINATE COUNTERTOP

w/ ROUNDED EDGE

BLOCKING AS REQUIRED

3' - 0" 3" F.V.

F.V.

1' - 0" 3' - 0" 3' - 0"

3' - 0"1' - 6"

F.V.

2' - 2 1/2"3' - 6"1' - 6"

FILLER PANEL

2'

1'

- 6

PLASTIC LAMINATE CASEWORK

w/ ADJ. SHELF

PLASTIC LAMINTE CASEWORK

w/ ADJ. SHELF

PLASTIC LAMINATE

COUNTERTOP & SPLASH

DOUBLE STAINLESS STEEL KITCHEN SINK

GOOSE NECK FAUCET, BLADE HANDLES

EXISTING

WINDOW

SYSTEM

NOTE:

PROVIDE FE ON ALL EXPOSED

CASEWORK

R1

3' - 0" 2' - 8" 1' - 0"

1'

- 6

2'

1'

- 6

PLASTIC LAMINATE CASEWORK

w/ ADJ. SHELF

PLASTIC LAMINTE CASEWORK

w/ ADJ. SHELF

PLASTIC LAMINATE

COUNTERTOP & SPLASH

NOTE:

PROVIDE FE ON ALL EXPOSED

CASEWORK

3' - 0" 3' - 0"

WALL - PAINT

EPOXY COVED BASE

PLASTIC LAMINATE CASEWORK

CENTER 1" SHELF FIXED

3 ADJUSTABLE SHELVES

WALL - PAINT

1' x 2' WALL TILE

EPOXY COVED BASE 4

2'

FIXTURE

1' x 2' WALL TILE

EPOXY COVED BASE

WALL - PAINT

SCHEDULED DOOR

& FRAME

1' - 6"

2' x 3' MIRROR

FIXTURE

WALL - PAINT

1' x 2' WALL TILE

EPOXY COVED BASE

1' x 2' WALL TILE

EPOXY COVED BASE

WALL - PAINT

CLEAR

3' - 0" MIN

CULTURED MARBLE SHOWER INSERT (3

SIDES) & ADA SHOWER PAN

w/ HAND-HELD SHOWER HEAD & TRACK

SLIDE, PROVIDE FOLDING SHOWER SEAT

MOUNTING PER ADA REQUIREMENTS,

VERIFY EXISTING DRAIN LOCATION

1' - 6"

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

/1

/2

:3

:4

A M

IN

TE

R

IO

R E

LE

V

A

TI

O N

S

25-001 act act

8/19/2026

INTERIOR

ELEVATIONS

A401

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

1/4" = 1'-0"A401

1 BAY ELEVATION

1/4" = 1'-0"A401

4 CASEWORK ELEVATION

3/8" = 1'-0"A401

2 STORAGE SECTION

3/4" = 1'-0"A401

6 CASEWORK SECTION (LEFT)

3/4" = 1'-0"A401

5 CASEWORK SECTION (RIGHT)

3/4" = 1'-0"A401

7 WORK DESK

1/4" = 1'-0"A401

8 KITCHEN ELEVATION 1

1/4" = 1'-0"A401

9 KITCHEN ELEVATION 2

8/19/2026

1/4" = 1'-0"A401

10 KITCHEN ELEVATION 3

KING STUD QUANTITIES

(10' MAX HEIGHT)

PLACE STUD AT TOP PLATE

SPLICE

DOUBLE TOP PLATE TO MATCH

STUD DEPTH

CRIPPLE STUDS @ 16" O.C.

HEADER TO TOP PLATE

KING STUD PER SCHED.

ATTACH TO JACK STUD W/ 16d @

12" O.C., STAGGERED

JACK STUD

HEADER

(MAY BE HELD UP AS DESIRED)

2X PLATE

2X PT SILL PLATE ON CONCRETE

2X SILL PLATE WHEN BEARING

ON WOOD

INTERIOR OPENINGS 1 KING STUD (MIN)

EXTERIOR OPENINGS <= 3'-6"

EXTERIOR OPENINGS > 3'-6" AND < 9'-0"

1 KING STUD (MIN)

2 KING STUD (MIN)

EXTERIOR OPENINGS > 9'-0" AND <= 15'-0" 3 KING STUD (MIN)

4 KING STUD (MIN)EXTERIOR OPENINGS > 15'-0" AND <= 21'-0"

WOOD STUD

HEADER

PAINTED HOLLOW METAL

FRAME

DOOR AS

SCHEDULED

CONT. SEALANT, BOTH

SIDES TYP.

2"

SEE WALL TYPES

(2) 2x6 HEADER w/ (2) STUDS

BOTH SIDES (1) JACK, (1) KING

FLASHING

SIDING - SEE ELEVATIONS

NEW 2x PLATE

ALUMINUM SLIDING WINDOW

CULTURED WINDOW SILL

ALL NEW & EXISTING WINDOWS

EXISTING FRAMED WALL

SCHEDULE

SEE

SC

H

E D

U

LE

SE

E

WD01

SOLID CORE WOOD

STAIN

DOOR AND WINDOW GENERAL NOTES

1. PROVIDE SEALANT @ JOINTS AT DISSIMILAR MATERIAL

CONNECTIONS, ISOLATE DISSIMILAR METALS.

2. ALL DIMENSIONS FOR DOOR & WINDOW OPENINGS TO BE

FIELD VERIFIED PRIOR TO MANUFACTURING & INSTALLATION.

GLAZING NOTES:

1. ALL GLAZING PANEL MEETING ALL OF THE FOLLOWING CRITERIA TO BE

SAFETY GLAZING COMPLYING w/ ALL APPLICABLE BUILDING CODES:

a) PANEL IS GREATER THAN 9 S.F.

b) PANEL IS WITHIN 18 INCHES OF FINISH FLOOR

c) PANEL IS GREATER THAN 60 INCHES ABOVE FINISH FLOOR

d) PANEL IS NEAR A WALKING PATH OR AREA

2. ALL SAFETY GLAZING TO HAVE PERMANENT LABELS/IDENTIFICATION

LOCATED ON GLAZING.

# GLASS TYPE SCHEDULE

1 1" GLASS, DOUBLE PANE

2"

SE

E S

C H

E D

U

LE

2"

SCHEDULE

SEE 2"

A501

A501

A

METAL HOLLOW

PAINT

FLOOR LEVEL

SLIDE

4' - 0"

AL01

ALUMINUM FRAME

SCHEDULE

SEE

SC

H

E D

U

LE

SE

E

HM01

HOLLOW METAL

PAINT

6" 2' - 0" 6"

SCHEDULE

SEE

SC

H

E D

U

LE

SE

E

HM02

HOLLOW METAL

PAINT

2"

SE

E S

C H

E D

U

LE

2"

SCHEDULE

SEE 2"

B

ALUMINUM

FINISH LEGEND

WALLS

W1 - PAINTED GYPSUM

MANUF: SHERWIN WILLIAM PROMAR 200

COLOR: TBD

FINISH: SEMI-GLOSS (PRIMER + 2 COATS)

W2 - FIBERGLASS REINFORCED PANEL

MANUF:

COLOR: WHITE

FINISH: 8'-0" HIGH, EMBOSSSED w/ EDGE TRIM

BASE

B1 - BASE

BY OWNER, INSTALLED BY OWNER

B2 - RUBBER BASE

MANUF: ROPPE

COLOR: MATCH EXISTING

FINISH: COVED

B3 - EPOXY COVED

COLOR: MATCH FLOORING

FINISH: 4" COVED

CEILING

C1 - EXISTING PAINTED GYPSUM

MANUF: SHERWIN WILLIAMS PROMAR 200

COLOR: TBD

FINISH: FLAT

FLOORS

F1- CARPET

BY OWNER, INSTALLED BY OWNER

F2 - EPOXY FLOORING

WALL

WALL

WALL

WALL

FLOOR

BASE

CEILING

MISC. COLORS

HOLLOW METAL FRAMES

MANUF: SHERWIN WILLIAMS

COLOR: TBD

FINISH: LATEX SEMI-GLOSS (2 COATS)

WOOD DOORS

COLOR: TBD

FINISH: STAIN

DOOR HARDWARE

COLOR: BRUSHED NICKEL

R1 - 2" PVC HORIZONTAL BLINDS

COLOR TO BE DETERMINED

WAND TILT & CORD LIFT

FURNISH ALL REQUIRED MOUNTING

HARDWARE

EXISTING WALL

REMOVE EXISTING

SIDING TO SHEATHING

SANDSTONE NATURAL STONE

3" EIFS

WEATHER BARRIER

PERIMETER FLASHING,

PRE-FINISHED, COLOR TBD

EXISTING WALL

REMOVE EXISTING

SIDING TO SHEATHING

EXISTING WINDOW SYSTEM

WEATHER BARRIER

PERIMETER FLASHING,

PRE-FINISHED, COLOR TBD

REMOVE EXISTING HORIZONTAL SIDING

INSTALL NEW HARD BOARD SIDING

EXISTING WALL

WEATHER BARRIER

1/2"

1"

3" EIFS MATERIAL

EXISTING WALL

WEATHER BARRIER

3" EIFS MATERIAL

METAL FLASHING

EXISTING FOUNDATION

2" GRADE - SLOPED

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

/1

/2

:3

:4

A M

M

IS

C . D

ET

A

IL

S

25-001 act act

8/19/2026

MISC. DETAILS

A501

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

3" = 1'-0"A501

3 HM DOOR HEAD/JAMB DETAIL

3/4" = 1'-0"A501

6 WINDOW HEAD/SILL

1/4" = 1'-0"A501

8 DOOR & WINDOW TYPES

1 1/2" = 1'-0"A501

1 EIFS TO STONE

1 1/2" = 1'-0"A501

2 EX WINDOW TO SIDING

3" = 1'-0"A501

4 EIFS V GROOVE

3" = 1'-0"A501

5 EIFS TO FOUNDATION

3/4" = 1'-0"A501

7 FRAMING DETAIL

085113 - ALUMINUM WINDOWS

PRODUCT

A. Manufacturers:

Kawneer Company Inc.

Series: slider

3-1/4" frame depth

B. Others:

1. UPON APPROVAL FROM THE ARCHITECT.

MATERIALS

A. Aluminum Extrusions: Alloy and temper recommended by aluminum window manufacturer for strength, corrosion resistance, and application of required finish and not less than 0.070" wall thickness at any location for the main frame and sash members.

B. Thermal Barrier: The thermal barrier shall consist of integral structural thermal break made with glass-reinforced nylon strips installed continuously and mechanically bonded to the aluminum.

C. Fasteners: Aluminum, nonmagnetic stainless steel or other materials to be non-corrosive and compatible with aluminum window members, trim, hardware, anchors, and other components.

D. Anchors, Clips, and Accessories: Aluminum, nonmagnetic stainless steel, or zinc-coated steel or iron complying with ASTM B633 for SC3 severe service conditions; provide sufficient strength to withstand design pressure indicated.

E. Reinforcing Members: Aluminum, nonmagnetic stainless steel, or nickel/chrome-plated steel complying with ASTM B456 for Type SC3 severe service conditions, or zinc-coated steel or iron complying with ASTM

B633 for SC3 severe service conditions; provide sufficient strength to withstand design pressure indicated.

Sealant: For sealants required within fabricated windows, provide window manufacturer's standard, permanently elastic, non-shrinking, and nonmigrating type recommended by sealant manufacturer for joint size and movement.

WINDOW SYSTEM

A. Slider

GLAZING

A. refer to drawings

HARDWARE

A. Provide manufacturer's standard hardware fabricated from aluminum, stainless steel, or other corrosion-resistant material compatible with aluminum; designed to smoothly operate, tightly close, and securely lock aluminum windows, and sized to accommodate sash weight and dimensions.

ACCESORIES

A. Stainless Steel Limit Arm with Key Release

B. Framing system gaskets, sealants, and joint fillers as recommended by manufacturer for joint type.

C. Sealants and joint fillers for joints at perimeter of window system.

D. Perimeter Anchors: When steel anchors are used, provide insulation between steel material and aluminum material to prevent galvanic action.

E. Insect Screens: (Full Screen) Field-mounted on interior with steel spring clips; handle-access wickets Black;

3/4" x 1-1/8" x .050" extruded tubular aluminum frame with finish to match window in color and performance; corners mitered, gusset reinforced, and crimped; 18 x 16 dark fiberglass; PVC splines.

F. Thermally Broken Construction: Fabricate aluminum windows with an integral, concealed, low-conductance thermal barrier. Thermal barriers shall be designed in accordance with AAMA TIR A8.

ALUMINUM FINISHES

A. Architectural Class II Clear Anodic Coating (Color #17 Clear) (Standard).

08200 - WOOD DOORS

PRODUCT

A. Manufacturer

1. Oshkosh Architectural Door Company

B. Others:

1. UPON APPROVAL FROM THE ARCHITECT.

MATERIALS

All stile and rail dimensions given are minimum sizes allowed after trimming to book size or factory prefitting.

A. Cores - SOLID CORE

Acoustical Door -

Doors are to be 1 3/4” thick and tested as an operable unit in accordance with ASTME90 and

ASTME 4l3. Stiles shall be same specie lumber as face veneer and rails mill option hardwood or SCL.

Sound Transmission Class: STC 44

B. PAINT GRADE

Doors with Opaque Finish -

Doors shall have medium density overlay faces meeting Government standards PSI74. Overlay shall be readily sandable, weatherproof, and carry a Class “B” Fire Rating. Paint grade Birch or hardboard shall not be considered as meeting this specification.

C. MISC.

Doors shall be suitable for hanging on full mortised butt hinges using No. 12 x 1 ¼” steel threaded-to-the head wood screws of the cadmium plated or rust resistant type. Half-surface hinges are not acceptable.

064116 - PLASTIC-LAMINATED-FACED ARCHITECTURAL CABINETS

PART 1 - SUMMARY

SECTION INCLUDES:

A. PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS.

B. SHOP DRAWINGS: SHOW LOCATION OF EACH ITEM, DIMENSIONED PLANS AND

ELEVATIONS, LARGE-SCALE DETAILS, ATTACHMENT DEVICES, AND OTHER COMPONENTS.

PART 2 - PRODUCTS

PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS

A. QUALITY STANDARD: UNLESS OTHERWISE INDICATED, COMPLY WITH THE

"ARCHITECTURAL WOODWORK STANDARDS" FOR GRADES OF ARCHITECTURAL PLASTIC-

LAMINATE CABINETS INDICATED FOR CONSTRUCTION, FINISHES, INSTALLATION, AND OTHER

REQUIREMENTS.

B. GRADE: CUSTOM.

C. TYPE OF CONSTRUCTION: FACE FRAME.

D. CABINET, DOOR, AND FRONT INTERFACE STYLE: FLUSH OVERLAY.

E. HIGH-PRESSURE DECORATIVE LAMINATE: NEMA LD 3, GRADES AS INDICATED OR IF NOT

INDICATED, AS REQUIRED BY WOODWORK QUALITY STANDARD.

F. HORIZONTAL SURFACES: GRADE HGS.

G. EDGES: ABS/PVC EXTRUDED FABRICATION.

H. MATERIALS FOR SEMIEXPOSED SURFACES:

1. SURFACES: HIGH-PRESSURE DECORATIVE LAMINATE, NEMA LD 3, GRADE VGS

I. COMPOSITE WOOD PRODUCTS: PRODUCTS SHALL BE MADE WITHOUT UREA

FORMALDEHYDE.

J. THERMOSET DECORATIVE PANELS (MELAMINE): PARTICLEBOARD OR MEDIUM-DENSITY

FIBERBOARD FINISHED WITH THERMALLY FUSED, MELAMINE-IMPREGNATED DECORATIVE

PAPER AND COMPLYING WITH REQUIREMENTS OF NEMA LD 3, GRADE VGL.

K. CABINET HARDWARE AND ACCESSORIES

1. SEMICONCEALED HINGES FOR FLUSH DOORS: BHMA A156.9, B01361.

2. SEMICONCEALED HINGES FOR OVERLAY DOORS: BHMA A156.9, B01521.

3. HINGES IN "FRAMELESS CONCEALED HINGES (EUROPEAN TYPE)"

4. BACK-MOUNTED PULLS: BHMA A156.9, B02011.

5. WIRE PULLS: BACK MOUNTED, SOLID METAL, 4 INCHES LONG, 5/16 INCH

IN DIAMETER.

6. CATCHES: MAGNETIC CATCHES, BHMA A156.9, B03141.

7. ADJUSTABLE SHELF STANDARDS AND SUPPORTS: BHMA A156.9, B04071; WITH

SHELF RESTS, B04081

8. DOOR LOCKS: BHMA A156.11, E07121.

9. DOOR SILENCERS: BHMA A156.16, L03011.

ADJUSTING AND CLEANING

A. REPAIR DAMAGED AND DEFECTIVE CABINETS, WHERE POSSIBLE, TO ELIMINATE

FUNCTIONAL AND VISUAL DEFECTS; WHERE NOT POSSIBLE TO REPAIR, REPLACE

WOODWORK. ADJUST JOINERY FOR UNIFORM APPEARANCE.

B. CLEAN, LUBRICATE, AND ADJUST HARDWARE. CLEAN CABINETS ON EXPOSED AND

SEMIEXPOSED SURFACES. CLEAN DECORATIVE PLASTIC LAMINATE SURFACES

ACCORDING TO MANUFACTURER'S WRITTEN CARE AND MAINTENANCE INSTRUCTIONS.

PROTECT COMPLETED WORK FROM DAMAGE FOR DURATION OF CONSTRUCTION PERIOD.

0074646 - FIBER-CEMENT SIDING

PART 1 GENERAL

SECTION INCLUDES

A. FACTORY-FINISHED FIBER CEMENT LAP SIDING, PANELS, TRIM, AND ACCESSORIES.

SUBMITTALS

A. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH PRODUCT TO BE USED, INCLUDING:

1. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS.

2. STORAGE AND HANDLING REQUIREMENTS AND RECOMMENDATIONS.

3. INSTALLATION METHODS.

B. SELECTION SAMPLES: FOR EACH FINISH PRODUCT SPECIFIED, TWO COMPLETE SETS OF COLOR

CHIPS REPRESENTING MANUFACTURER'S FULL RANGE OF AVAILABLE COLORS AND PATTERNS.

WARRANTY

A. PRODUCT WARRANTY: LIMITED, NON-PRO-RATED PRODUCT WARRANTY.

1. PANELS FOR 30 YEARS.

B. FINISH WARRANTY: LIMITED PRODUCT WARRANTY AGAINST MANUFACTURING FINISH DEFECTS.

1. WHEN USED FOR ITS INTENDED PURPOSE, PROPERLY INSTALLED AND MAINTAINED

ACCORDING TO PUBLISHED INSTALLATION INSTRUCTIONS, FOR A PERIOD OF 15 YEARS

FROM THE DATE OF PURCHASE: WILL NOT PEEL; WILL NOT CRACK; AND WILL NOT CHIP.

FINISH WARRANTY INCLUDES THE COVERAGE FOR LABOR AND MATERIAL.

C. WORKMANSHIP WARRANTY: APPLICATION LIMITED WARRANTY FOR 2 YEARS.

PART 2 PRODUCTS

MANUFACTURERS

A. ACCEPTABLE MANUFACTURER: JAMES HARDIE BUILDING PRODUCTS, INC.,

B. SUBSTITUTIONS: APPROVED EQUAL.

SIDING AND TRIM

1. FIBER-CEMENT SIDING - COMPLIES WITH ASTM C 1186 TYPE A GRADE II.

2. TYPE: SMOOTH 7-1/4 INCHES (184 MM) WITH 6 INCHES EXPOSURE.

3. TRIM ACCESSORIES PER MANUFACTURER.

FINISHES

A. FACTORY PRIMER: PROVIDE FACTORY APPLIED UNIVERSAL PRIMER.

1. PRIMER: FACTORY PRIMED.

PART 3 EXECUTION

A. DO NOT BEGIN INSTALLATION UNTIL THE SUBSTRATES HAVE BEEN PROPERLY PREPARED.

B. INSTALL RESISTIVE BARRIERS OR VAPOR BARRIERS.

1. INSTALL WATER-RESISTIVE BARRIERS AND CLADDINGS TO DRY SURFACES.

2. REPAIR ANY PUNCTURES OR TEARS IN THE WATER-RESISTIVE BARRIER PRIOR TO THE

INSTALLATION OF THE SIDING.

3. PROTECT SIDING FROM OTHER TRADES.

PREPARATION

A. FOLLOW ALL MANUFACTURER REQUIREMENTS.

PROTECTION

A. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT.

B. TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE SUBSTANTIAL COMPLETION.

08100 - STANDARD HOLLOW METAL DOORS & FRAMES

Product

A. Manufacturer

1. APPROVED BY ARCHITECT

Materials

A. All steels used to manufacture doors, frames, anchors, and accessories shall meet at least one or more of the following requirements:

1. Cold rolled steel shall conform to ASTM designations A1008, Standard Specification for Steel Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength

Low-Alloy with Improved Formability and A568, Standard Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General

Requirements for.

2. Hot rolled, pickled and oiled steel shall comply with ASTM designations A1011, Standard

Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength

Low-Alloy and High-Strength Low-Alloy with Improved Formability and A568, Standard

Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for.

3. Hot dipped zinc coated steel shall be of the alloyed type and comply with ASTM designations A924, Standard Specification for General Requirements for Steel Sheet, Metallic Coated by the Hot-Dip Process and A653, Standard Specification for Steel Sheet, Zinc Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip

Process.

B. Frames

1. Exterior frames

a. Level 2 for door model 2 0.053″ (1.3mm) minimum steel thickness for frames.

b. Frames shall be full profile weld type.

c. Provide frames with a minimum of three anchors per jamb suitable for the adjoining wall construction. Provide anchors of not less than 0.042″ (1.0 mm) in thickness or 0.167″ (4.2 mm) diameter wire.

d. All frames shall be fully prepared for all mortise template hardware and reinforced only for surface mounted hardware. Drilling and/or tapping shall be completed by others.

C. Doors

1. Doors shall meet at least one or more of the following requirements:

a. Level 2 – Heavy duty 1-3/4″ (44.5 mm)

Model 2 – Seamless

D. Door and panel construction

1. Face steel sheet shall meet the following requirements:

a. Level 2 - Model 2 – 0.042″ (1.0mm) minimum thickness

b. End closure: The top and bottom of the doors shall be closed with flush channels or closures. The channels or closures shall have a minimum material thickness of 0.042″ (1.0mm).

c. Core: See ANSI/SDI A250.8, Specifications for Standard Steel Doors and

Frames (SDI 100), Section 2.3.2.

d. Door edge design: See ANSI/SDI A250.8, Specifications for Standard Steel

Doors and Frames (SDI-100), Section 2.3.1.3.

E. Finishing

A. Prime finish: Doors and frames shall be thoroughly cleaned, and chemically treated to insure maximum paint adhesion. All surfaces of the door and frame exposed to view shall receive a factory applied coat of rust inhibiting primer, either air-dried or baked-on. The finish shall meet the requirements for acceptance stated in ANSI/SDI A250.10 Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and

Frames.

B. Design clearances

1. The clearance between the door and frame head and jambs shall be 1/8″ (3.2 mm)

2. The clearance at the bottom shall be 5/8″ (15.8 mm).

HARDWARE SETS

SET #1.0

NOT USED

SET #2.0

NOT USED

SET #3.0

NOT USED

SET #4.0

DOORS: 1, 2, 3, 5

3 BUTT HINGE FBB179 4.5" X 4.5" 26D ST

1 PRIVACY SET 9K3-0LL15D 626 BE

1 DOOR CLOSER EHD9016 AF90 DA AVB 689 BE

1 OVERHEAD STOP 9024 RA US32D AB

1 KICK PLATE K050 10" X 2" LDW B4E CSK 630 AB

1 GASKETING 5050 B-17 17' NA

1 AUTO DOOR BOTTOM 420NA NA

SET #5.0

DOORS: 4

3 BUTT HINGE FBB179 4.5" X 4.5" 26D ST

1 PRIVACY SET 9K3-0L15D 626 BE

1 DOOR CLOSER EHD9016 AF90 DA AVB 689 BE

1 OVERHEAD STOP 9024 RA US32D AB

1 KICK PLATE K050 10" X 2" LDW B4E CSK 630 AB

1 GASKETING 5050 B-17 17' NA

SET #6.0

NOT USED

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt a rc h it e c tu re

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

ANDY TONGISH 801-865-0633

TI

TL

E

P R

O

JE

C T

C

LI

EN

T

A D

D R

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

/1

/2

:3

:4

A M

SP

EC

IF

IC

A

TI

O N

S

25-001 act act

8/19/2026

SPECIFICATIONS

SP1

W A

N

SH

IP

F

IR

E

ST

A

TI

O

N

N O

R

TH

S U

M M

IT

F

IR

E

D

EP

A R

TM

EN

T

S O

U

TH

H O

Y

TS

V

IL

LE

R

O A

D C

O A

LV

IL

LE

, U

TA

H

8/19/2026

GENERAL NOTES:

PAINT

GARAGE PAINT INCLUDES ALL TRIM, WALLS, AND CEILINGS WILL BE THE SAME COLOR AND

SHEEN. INCLUDES:

1. PROTECT ALL ADJACENT SURFACES.

2. REPAIR MINOR IMPERFECTIONS.

3. APPLY STAIN BLOCKING PRIMER.

4. APPLY (2) COATS OF FINISH PAINT.

OVERHEAD DOORS

REMOVE AND REPLACE GARAGE DOORS. PROVIDE (3) HAAS CHT710 STEELBACK INSULATED

DOORS WITH VISION PANELS,

INCLUDES LIFTMASTER OPERATORS, INCLUDES RED/GREEN STOP LIGHTS, SEE ELECTRICAL.

APPARATUS BAY LIGHTING

DEMO OLD LIGHT FIXTURES. INSTALL NEW LED 200 WATT HIGH BAY LIGHTS (10). WIRING TO

EACH LIGHT.

FLOORING

EPOXY FULL FLAKE SYSTEM IN

KITCHEN, BATHROOM, LAUNDRY, AND DINING.

GARAGE EPOXY FLOOR SYSTEM

APLYING A POLYASPARTIC COATING SYSTEM TO THE GARAGE. INCLUDES PAINTED WHITE

PARKING LINES. THE FOLLOWING APPLY:

1- GRIND/SHOT BLAST THE FLOOR CREATING A MECHANICAL BOND.

2- PREP THE JOINTS AND INSTALL SIKAFLEX.

3- PLEASE NOTE IF ANY VERTICAL SURFACES ARE INCLUDED THEY WILL VARY IN APPEARANCE

BOTH IN FLAKE AND CLEAR.

4- CLEAN THE FLOOR.

5- APPLY AN MVB EPOXY COATING WITH A BROADCAST OF FLAKE. COLOR IS TO BE A NORMAL

BLEND IF YOU GO INTO HYBRID OPTION AN ADDITIONAL CHARGE PER BOX WILL BE APPLIED.

6- BLOW LEFTOVER FLAKE INTO A CORNER.

7- SCRAPE THE FLAKE 4 DIRECTIONS. BLOW INTO THE CORNER FOR THE SECOND TIME.

8- CLEAN UP THE FLAKE WITH A VACUUM.

9- APPLY A CLEAR COAT OF SHERWIN WILLIAMS MPE AND FULLY BROADCAST FLAKE.

10- SCRAPE THE FLAKE IN ALL FOUR DIRECTIONS AND CLEAN UP THE LOOSE FLAKE.

11- APPLY THE FIRST CLEAR COAT TOP COAT WITH A POLYASPARTIC.

12- APPLY THE SECOND TOP COAT WITH A POLYASPARTIC.

GARAGE WATERLINE SUPPLY UPGRADES.

PARKING BUMPERS

INSTALL PARKING BUMPERS TO PROTECT BUILDING.

CULTURE MARBLE SHOWER

INSTALL CULTURE MARBLE SHOWER ENCLOSURE.

WATERLINE

UPGRADE EXISTING WATERLINE SUPPLY FOR TRUCK FILLING.

ADD HOSEBIB FOR DE-IONIZER.

ADD REINFORCED FAUCET FOR HOSE REEL.

STOREFRONT DOORS - TRULITE ENTRANCES

TRULITE SERIES 300 MEDIUM STILE SWING ENTRANCES.

WIDE STILE SWING DOORS: TRULITE SERIES 500: 5” (127 MM) DOOR STILES

ARCHITECTURAL CLASS II, ETCHED, MEDIUM MATTE, CLEAR ANODIC COATING, 0.4 MIL MINIMUM

THICKNESS.

AD

AREA DRAIN

AFF ABOVE FINISHED FLOOR

AP ACCESS PANEL

ATC AUTOMATIC TEMPERATURE CONTROL

AW AIR WASHER

B BOILER

BB BASEBOARD

AUTO AUTOMATIC

BDD BACKDRAFT DAMPER

BFP BACKFLOW PREVENTOR

BOU BOTTOM OF UNIT

CC COOLING COIL

CFM CUBIC FEET PER MINUTE

CH CHILLER

CI CAST IRON

CLG CEILING

CO CLEAN OUT

CONN CONNECTION

CP CIRCULATING PUMP

CT COOLING TOWER

CU CONDENSING UNIT

COPPER

CW COLD WATER

DB DRY BULB

DF DRINKING FOUNTAIN

DH DUCT HEATER

DIA DIAMETER

DN DOWN

DWG DRAWING

EA EXHAUST AIR

EAT ENTERING AIR TEMPERATURE

EC ELECTRICAL CONTRACTOR

EVAPORATIVE COOLER

EH ELECTRIC HEATER

EL ELEVATION

ESP EXTERNAL STATIC PRESSURE

EW EMERGENCY EYE WASH

EX EXISTING

F FURNACE

FC FAN COIL UNIT

FD FLOOR DRAIN

FH FIRE HYDRANT

FL FILTER

FLR FLOOR

FOB FLAT ON BOTTOM

FOS FLAT ON SIDE

FOT FLAT ON TOP

FS FLOOR SINK

FU FIXTURE UNIT

GA GAUGE

GC GENERAL CONTRACTOR

GPM GALLONS PER MINUTE

GRD GRADE

HB HOSE BIBB

HDR HEADER

HP HEAT PUMP

HTR HEATER

HU HUMIDIFIER

HVAC HEATING, VENTILATING &

HW HOT WATER

IE INVERT ELEVATION

INSUL INSULATION

LAT LEAVING AIR TEMPERATURE

LAV LAVATORY

MAX MAXIMUM

MBH THOUSAND BTU PER HOUR

MC MECHANICAL CONTRACTOR

MECH MECHANICAL

MH MANHOLE

MIN MINIMUM

MU MAKE-UP AIR UNIT

NIC NOT IN CONTRACT

NTS NOT TO SCALE

OA OUTSIDE AIR

ORD OVERFLOW ROOF DRAIN

P PUMP

PRV PRESSURE REDUCING VALVE

P&TV PRESSURE & TEMPERATURE RELIEF VALVE

PSI POUNDS PER SQUARE INCH

PVC POLYVINYL CHLORIDE

QD QUICK DISCONNECT

RA RETURN AIR

RD ROOF DRAIN

RF RELIEF AIR

RI ROUGH-IN

RP RADIANT PANEL

RT ROOFTOP UNIT

RV RELIEF VENT

REQD REQUIRED

SA SUPPLY AIR

SD STORM DRAIN

SF SUPPLY FAN

SP STATIC PRESSURE

SPEC SPECIFICATION

SS STAINLESS STEEL

ST SOUND TRAP

STD STANDARD

TOD TOP OF DUCT

TW THROUGH WALL UNIT

TYP TYPICAL

UH UNIT HEATER

VAV VARIABLE AIR VOLUME

VB VACUUM BREAKER

VTR VENT THROUGH ROOF

W/ WITH

WB WET BULB

WC WATER CLOSET

WH WATER HEATER

AxB BARE SHEET METAL RECTANGULAR DUCT, 'A' AND 'B' ARE INSIDE CLEAR DIMENSIONS.

BARE SHEET METAL ROUND MEDIUM OR LOW

INSULATED ROUND FLEXIBLE DUCT, 5 FEET MAXIMUM.

DIRECTION OF AIRFLOW

SUPPLY DUCT RISER

SUPPLY DUCT DROP

RETURN, EXHAUST, OR OUTSIDE AIR DUCT

RISER

RETURN, EXHAUST, OR OUTSIDE AIR DUCT

DROP

ROUND DUCT DROP

ROUND DUCT RISER

MANUAL VOLUME DAMPERS (SQUARE OR ROUND)

DUCT ACCESS DOOR

INTAKE LOUVER WITH BIRDSCREEN

EXHAUST LOUVER WITH BIRDSCREEN

T THERMOSTAT OR SENSOR

CLEAN OUT

VENT LINE

VENT THROUGH ROOF

140° F. HOT WATER

160° F. HOT WATER

BUTTERFLY VALVE

BALL VALVE

GATE VALVE

CHECK VALVE

PLUG VALVE

PRV

2-WAY AUTO VALVE

3-WAY AUTO VALVE

THERMOMETER

GAUGE

UNION

VTR

140°

160°

120° 120° F. HOT WATER

STRAINER

BALANCING VALVE

RELIEF VALVE

BACKFLOW PREVENTER

PIPE ANCHOR

DIRECTION OF FLOW

EXPANSION JOINT

FLEXIBLE CONNECTION

PIPING TEE DROP TO BELOW

PIPING ELBOW DROP

UNDERGROUND SANITARY SEWER

ABOVE GROUND SANITARY SEWER

UNDERGROUND COLD WATER

UNDERGROUND HOT WATER (120° F.)

ABOVE GROUND COLD WATER

ABOVE GROUND HOT WATER

HOSE BIBB

FLOOR DRAIN

FLOOR SINK

FIRE HYDRANT

GLOBE VALVE

CONNECTION OFF SIDE

CONNECTION OFF BOTTOM

CONNECTION OFF TOP

WATER HAMMER ARRESTER

CAPPED END

SHEET NUMBER/DRAWING TITLE

LEGEND

OXYGEN

VACUUM

ACCESS DOOR

AC ACCESS COVER

AIR ADMITTANCE VALVEAV

BOTTOM OF DUCTBOD

AIR CONDITIONING

AH AIR HANDLING UNIT

BTU BRITISH THERMAL UNIT

BTUH BRITISH THERMAL UNIT PER HOUR

CLR CLEAR

CA COMBUSTION AIR

CD CONDENSATE DRAIN

CONSTRUCTION DOCUMENT

CFH CUBIC FEET PER HOUR

BLD BUILDING

DUCT FURNACE

DESTRATIFICATION FAN

DOWN FLOW

DM DAMPER

DA DILUTION AIR

EQ EQUIPMENT

ENTERING WATER TEMPERATUREEWT

EWC ELECTRIC WATER COOLER

FIRE DAMPER

EXHAUST HOSE

DRAINAGE FIXTURE UNITDFU

FSD FIRE/SMOKE DAMPER

FP FIREPLACE

GI GREASE INTERCEPTOR

GREASE TRAPGT

DOMESTIC COLD WATERDCW

DOMESTIC HOT WATERDHW

CHWR CHILLED WATER RETURN

CHWS CHILLED WATER SUPPLY

CWR CONDENSER WATER RETURN

CWS CONDENSER WATER SUPPLY

CONDENSATE RETURNCR

HE HEAT EXCHANGER

HWR HOT WATER RETURN

HWS HOT WATER SUPPLY

L LOUVER

LPG LIQUEFIED PETROLEUM GAS

MANUAL DAMPERMD

NATURAL GASNATGAS

PENT HOUSEPH

RH RELIEF HOOD

RADIANT HEATER

RECIRCULATION PUMP

RELIEF VALVE

SMOKE EXHAUST FANSEF

IH INTAKE HOOD

SANITARY SEWER

GW GREASE WASTE

SELF CONTAINED UNITSC

VAV BOX

UR URINAL

WATER HAMMER ARRESTORWA

CENTER LINECL

OC ON CENTER

ON CENTER EACH WAYOCEW

EF EXHAUST FAN

RAG RETURN AIR GRILLE

TAG TRANSFER AIR GRILLE

FAN POWERED VAV BOXFB

ABBREVIATIONS

1" LINED SHEET METAL RECTANGULAR DUCT, OR

1" FIBERGLASS DUCT, SEE DRAWINGS FOR TYPE,

AxB

'A' IS WIDTH OF DUCT IN VIEW SHOW.

AxB 1 1/2" WRAPPED SHEET METAL RECTANGULAR DUCT, 'A' IS WIDTH OF DUCT IN VIEW SHOW.

A"Ø

PRESSURE DUCT, A"Ø IS DIAMETER.

PRESSURE DUCT, A"Ø IS DIAMETER.

1 1/2" WRAPPED ROUND MEDIUM OR LOWA"Ø

MOTORIZED DAMPER OR FIRE/SMOKE DAMPER

FIRE DAMPER

RECTANGULAR ELBOW WITH TURNING VANES

SLOT DIFFUSER

SQUARE DIFFUSER

ROUND DIFFUSER

24x24 RETURN AIR GRILLE

24x12 RETURN AIR GRILLE

DUCT MOUNTED GRILLE (RECTANGULAR)

BARE SHEET METAL ROUND MEDIUM OR LOW

S SWITCH

H HUMIDITY SENSOR

COMPRESSED AIRA

CD CONDENSATE DRAIN

CONDENSATE RETURNCR

CONDENSER WATER RETURNCWR

CONDENSER WATER SUPPLYCWS

CHILLED WATER RETURNCHWR

CHWS CHILLED WATER SUPPLY

HOT WATER SUPPLY

HOT WATER RETURN

HWS

HWR

NATURAL GASG

OVERFLOW ROOF DRAINOD

HOT WATER RECIRCULATION LINE

ROOF DRAINRD

STEAMS

SOFT COLD WATERSCW

SOFT HOT WATERSHW

V

PIPING ELBOW RISER

SS

SS

SS

SS

DRAWING INDEX

MATERIAL SPECIFICATIONS

RETURN DUCT - SINGLE WALL SHEET METAL WITH 1" LINER.

SUPPLY DUCT - SINGLE WALL SHEET METAL WITH 1" LINER.

MECHANICAL SPECIFICATIONS (UNLESS NOTED OTHERWISE ON PLANS)

LOW PRESSURE ROUND DUCT

PLUMBING SPECIFICATIONS (UNLESS NOTED OTHERWISE ON PLANS)

LOW PRESSURE RECTANGULAR DUCT

SUPPLY DUCT - SINGLE WALL SHEET METAL WITH 1 1/2" INSULATION WRAP (WHERE SHOWN)

RETURN DUCT - SINGLE WALL SHEET METAL WITH 1 1/2" INSULATION WRAP.

EXHAUST DUCT - SINGLE WALL SHEET METAL.

EXHAUST DUCT - SINGLE WALL SHEET METAL.

BELOW GRADE DUCT (ROUND OR RECTANGULAR)

SUPPLY DUCT - SINGLE WALL SHEET METAL WITH PVS COATING.

RETURN DUCT - SINGLE WALL SHEET METAL WITH PVS COATING.

COMBUSTION AIR DUCT - SINGLE WALL SHEET METAL.

FLUE PIPING

SINGLE WALL - ALUMINUM SINGLE WALL (SEE DRAWINGS FOR LOCATIONS).

DOUBLE WALL - ALUMINUM B-VENT PIPE.

DOMESTIC WATER - TYPE 'K' COPPER TUBING WITH LEAD-FREE SOLDER JOINTS.

SANITARY WASTE - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.

BELOW GRADE PIPING

NATURAL GAS -

ROOF DRAINS - SCH40 PVC DWV PIPING WITH SOLVENT GLUED DWV FITTINGS.

ABOVE GRADE PIPING

NATURAL GAS - 2" AND UNDER SCH 40 BLACK PIPE WITH THREADED JOINTS.

NATURAL GAS - 2 1/2" AND OVDER SCH 40 BLACK PIPE WITH WELDED JOINTS.

CONDENSATE DRAINS - (INSIDE) SCH40 PVC WITH SOLVENT CEMENT JOINTS.

CONDENSATE DRAINS - (OUTSIDE) TYPE 'M' CU TUBING WITH SOLDER JOINTS.

GENERAL NOTES

'A' IS WIDTH OF DUCT IN VIEW SHOWN.

'A' AND 'B' ARE INSIDE CLEAR DIMENSIONS.

'A' AND 'B' ARE INSIDE CLEAR DIMENSIONS.

DOMESTIC COLD WATER - 2 1/2" AND OVER TYPE 'L' COPPER TUBING WITH LEAD

FREE SOLDER JOINTS AND 1/2" INSULATION.

DOMESTIC HOT WATER - 2 1/2" AND OVER TYPE 'L' COPPER TUBING WITH LEAD

FREE SOLDER JOINTS AND 1" INSULATION.

DOMESTIC COLD WATER - 2" AND UNDER PEX TUBING WITH METAL

FITTINGS AND STAINLESS STEEL CLAMP BANDS.

DOMESTIC HOT WATER - 2" AND UNDER PEX TUBING WITH METAL

FITTINGS AND STAINLESS STEEL CLAMP BANDS.

HOT WATER RECIRC. - PEX TUBING WITH METAL FITTINGS AND

STAINLESS STEEL CLAMP BANDS.

SANITARY WASTE - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.

SANITARY VENT - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.

ABOVE GRADE PIPING (CONT.)

TH

IS

D

RA

W

IN

G

SH

EE

T

AN

D

AL

L I

NF

OR

MA

TI

ON

H

ER

EO

N

IS

C

OP

YR

IG

HT

ED

A

ND

T

HE

P

RO

PE

RT

Y

OF

JT

B

HV

AC

P

LU

MB

IN

G

EN

GI

NE

ER

IN

G, IN

C.

A

ND

S

HA

LL

N

OT

B

E

US

ED

O

N

AN

Y

OT

HE

R

PR

OJ

EC

T

W

IT

HO

UT

W

RI

TT

EN

P

ER

MI

SS

IO

N

FR

OM

JT

B

HV

AC

P

LU

MB

IN

G

EN

GI

NE

ER

IN

G, IN

C.

MECHANICAL PLANS

ROOF DRAINS - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.

PROVIDE 1" INSULATION ON BOWL AND FIRST 10'-0" OF PIPING.

AIR CONDITIONING

1" FIBERGLASS INSULATION FOR PIPING 1 1/4" AND SMALLER.

DOMESTIC PIPING INSULATION

1 1/2" FIBERGLASS INSULATION FOR PIPING 1 1/2" AND LARGER.

OUTSIDE AIR DUCT - SINGLE WALL SHEET METAL WITH 1" LINER.

OUTSIDE AIR DUCT - SINGLE WALL SHEET METAL WITH 1 1/2" INSULATION WRAP.

A) THESE DRAWINGS WERE PREPARED USING THE 2021 IBC, 2021 IMC,

2021 IPC, 2021 IFGC, AND THE 2021 IECC.

B) ALL INSTALLATIONS SHALL BE PER THE 2021 IBC, 2021 IMC, 2021 IPC,

2021 IFGC, AND THE 2021 IECC.

D) REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF

PLUMBING FIXTURES, LIGHTS, CEILING DIFFUSERS, AND FIRE SPRINKLERS.

C) THESE DRAWINGS ARE TO SHOW THE GENERAL CONCEPT OF THE

SYSTEMS. FIELD VERIFY ALL LOCATIONS AND COORDINATE EXACT

ROUTING WITH ALL TRADES.

E) ALL DUCT SIZES LISTED IN THESE DRAWINGS ARE INSIDE CLEAR

DIMENSIONS UNLESS NOTED OTHERWISE.

F) SLOPE ALL HORIZONTAL SANITARY WASTE AND VENT PIPING A MINIMUM OF

A 1/4" PER FOOT FOR 2 1/2" AND SMALLER, 1/8" PER FOOT FOR 3" TO

6", AND 1/16" FOR 8" AND LARGER.

G) SLOPE ALL HORIZONTAL ROOF DRAINAGE PIPING A MINIMUM OF A 1/8"

PER FOOT UNLESS NOTED OTHERWISE.

H) ALL MATERIALS INSTALLED IN AN AREA ABOVE THE CEILING DESIGNATED

AS A RETURN AIR PLENUM MUST BE NONCOMBUSTIBLE OR SHALL HAVE

A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-

DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE

J) ALL UNDERGROUND DUCT SHALL SLOPE TO ALLOW DRAINAGE TO A POINT

PROVIDED WITH ACCESS.

K) PROVIDE CLEANOUTS EVERY 100 FEET ON HORIZONTAL WASTE LINES,

EVERY CHANGE OF DIRECTION GREATER THAN 45°, AT THE BASE OF

BUILDING.

WASTE STACKS, AND NEAR THE POINT THE SEWER ENTERS THE

WITH ASTM E 84.

L) SEISMIC RESTRAINTS ARE REQUIRED PER 2021 IBC. ENGINEERING AND

RESTRAINT SELECTION ARE THE RESPONSIBILITY OF THE MECHANICAL AND

PLUMBING CONTRACTORS.

M) FIRESTOPPING DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE INSTALLING

CONTRACTOR.

N) FIRESTOPPING DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE INSTALLING

CONTRACTOR.

O) AS-BUILT DRAWINGS SHALL BE PROVIDED TO THE OWNER OR OWNERS REPRESENTATIVE

WITHIN 90 DAYS OF CERTIFICATION OF OCCUPANCY.

P) O&M MANUALS FOR THE PROJECT SHALL BE PROVIDED TO THE OWNER OR

OWNERS REPRESENTATIVE WITHIN 90 DAYS OF CERTIFICATION OF

Q) PROVIDE AIR AND WATER BALANCING REPORTS TO BUILDING INSPECTOR

PRIOR TO FINAL INSPECTION.

OCCUPANCY AND INCLUDE THE FOLLOWING ITEMS: EQUIPMENT

SUBMITTALS, MANUFACTURES O&M'S, NAME AND ADDRESS OF AT LEAST

ONE SERVICE AGENCY, HVAC AND SERVICE HOT WATER CONTROLS

MAINTENANCE AND CALIBRATION INFORMATION, AND A NARRATIVE OF

R) PIPE EXPANSION JOINTS IN THE VERTICAL RISERS AND HORIZONTAL RUNS

ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR. FOLLOW

THE INSTALLATION RECOMMENDATIONS FOR EACH PIPE MANUFACTURE.

EXPANSION JOINTS SHOWN IN THE DRAWINGS ARE MINIMUM

REQUIREMENTS AND WILL VARY BASED ON ACTUAL PIPE ROUTING.

IF DESIGN ASSISTANCE IS NEEDED PLEASE CONTACT JTB.

HOW EACH PIECE OF EQUIPMENT IS TO OPERATE INCLUDING SETPOINTS.

M001 TITLE SHEET (LEGEND & ABBREVIATIONS)

M201 MECHANICAL PLAN

P201 PLUMBING PLAN

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt ar ch ite ct ur e

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

TIT

LE

PR

O

JE

C

T

C

LIE

NT

AD

DR

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

TIT

LE

SH

EE

T -

LE

G

EN

D

AB

BR

EV

IA

TIO

NS

TITLE

PAGE

M001

W

AN

SH

IP

FI

RE

ST

AT

IO

N

NO

RT

H

SU

M M

IT

FIR

E

DE

PA

RT

M

EN

T

SO

UT

H

HO

YT

SV

ILL

E

RO

AD

C

O

AL

VI

LL

E, U

TA

H

25.053

JCZ

JTM

7/14/2026

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text #264382

AutoCAD SHX Text

BROWN

AutoCAD SHX Text H

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text

JEFF T.

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text G

R

EF

W D

REF.

KEYED NOTES

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt ar ch ite ct ur e

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

TIT

LE

PR

O

JE

C

T

C

LIE

NT

AD

DR

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

M

EC

HA

NI

C

AL

P

LA

N

MECHANICAL

PLAN

M201

25.053

JCZ

JTM

7/14/2026

W

AN

SH

IP

FI

RE

ST

AT

IO

N

NO

RT

H

SU

M M

IT

FIR

E

DE

PA

RT

M

EN

T

SO

UT

H

HO

YT

SV

ILL

E

RO

AD

C

O

AL

VI

LL

E, U

TA

H

SCALE:

MECHANICAL PLAN

1/4" = 1'-0"

NORTH

0 1' 2' 4' 8'

HP

PIPE CONDENSATE TO LAV TAILPIECE

DS

DS

DS

LIQUID SUCTION DIFF MAX

HP

ELECTRICAL

MULTI-ZONE OUTDOOR HEAT PUMP UNIT SCHEDULE

HEAT PUMP UNIT LOCATION

AREA SERVED

HP

TAG TONS/

NOMINAL

POWER

V/PH/HZ

BTU/H

DX COOLING CAP.

HEAT PUMP UNIT MANUFACTURER

REFRIGERANT

inches

CONNECTIONS

NECT/

STARTER

DISCON-MCA/

FUSE MODEL NUMBER

OPER.

WEIGHT

lbs.EFF. AMBIENT 94/59°F

BTU/H

AMBIENT

-5°F

DX HEAT CAP.

TYPE feet

MAX PIPE

ON GRADE

SLEEPING - R-410A 1/4 1/2 150

DAIKIN

3MXL24WMVJU9STD

24,000

BY EC

N/A 49 13220

17.5 208/1/6024,000

DUCTLESS SPLIT INDOOR UNIT SCHEDULE

DUCTLESS SPLIT INDOOR UNIT MANUFACTURER

MODEL NUMBER

CFM

at

5,300'

EXT.

SP

inches

ELECTRICAL

EAT LATSENSIBLE TOTAL

BTUH

OPER.

WEIGHT

lbs.

DESIGN COND

°F DB/WB

COOLING AIR

WALL

DUCTLESS SPLIT INDOOR UNIT LOCATION

AREA SERVEDTAG POWER

V/PH/HZ NECT/

STARTER

DISCON-MCA/

FUSE

-300

-7,0007,000SLEEPING 1 208/1/60 - N/A

- HP-1

CTXS07WVJU9

DAIKIN

HEATING

EAT LAT

DESIGN COND

°F DB/WB

TOTAL

8,000

BTUH

1 PROVIDE CONDENSATE PUMP AND WALL MOUNTED THERMOSTAT.

DS

WALL

SLEEPING 2

DS

WALL

SLEEPING 3

DS

-300

-7,0007,000 208/1/60 - N/A

- HP-1

CTXS07WVJU9

DAIKIN

-8,000

-300

-7,0007,000 208/1/60 - N/A

- HP-1

CTXS07WVJU9

DAIKIN

-8,000

SCALE:

DRYER WALL VENT DETAILA NTS

FASTENER THRU

NYLON SLEEVE

SEALANT AT PERMIETER

OF PENETRATION

DRYER VENT

SET FLANGE IN SEALANT

FASTENER SET IN SEALANT

4"

AutoCAD SHX Text

THROUGHOUT THE

AutoCAD SHX Text

NO WORK IN THIS AREA

AutoCAD SHX Text T

AutoCAD SHX Text

SLEEPING 1

AutoCAD SHX Text

SLEEPING 2

AutoCAD SHX Text

SLEEPING 3

AutoCAD SHX Text

OFFICE/SLEEPING 4

AutoCAD SHX Text

MECHANICAL

AutoCAD SHX Text

STORAGE

AutoCAD SHX Text

KITCHEN

AutoCAD SHX Text

RESTROOM

AutoCAD SHX Text

RESTROOM

AutoCAD SHX Text

EQUIPMENT BAY

AutoCAD SHX Text

GROUP ROOM

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text

SHOWER

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text G

AutoCAD SHX Text I

AutoCAD SHX Text #264382

AutoCAD SHX Text

BROWN

AutoCAD SHX Text H

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text E

AutoCAD SHX Text T

AutoCAD SHX Text A

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text N

AutoCAD SHX Text E

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text E

AutoCAD SHX Text

JEFF T.

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text P

AutoCAD SHX Text R

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text S

AutoCAD SHX Text I

AutoCAD SHX Text O

AutoCAD SHX Text N

AutoCAD SHX Text A

AutoCAD SHX Text L

AutoCAD SHX Text E

AutoCAD SHX Text N

WD

REF.REF.

WD

REF.REF.

KEYED NOTES

PROJECT #:

DRAWN BY:

CHECKED BY:

ISSUED:

alt ar ch ite ct ur e

1445 w. 8660 s.

west jordan, utah 84088 www.altarchitecture-ut.com

TIT

LE

PR

O

JE

C

T

C

LIE

NT

AD

DR

ES

S

NO. DATE DESCRIPTION

SHEET

REVISIONS

PL

UM

BIN

G

P

LA

N

PLUMBING

PLAN

P201

25.053

JCZ

JTM

8/10/2026

W

AN

SH

IP

FI

RE

ST

AT

IO

N

NO

RT

H

SU

M M

IT

FIR

E

DE

PA

RT

M

EN

T

SO

UT

H

HO

YT

SV

ILL

E

RO

AD

C

O

AL

VI

LL

E, U

TA

H

SCALE:

PLUMBING PLAN

1/4" = 1'-0"

NORTH

0 1' 2' 4' 8'

PIPE CONDENSATE TO LAV TAILPIECE

DS

DS

DS

2 CONNECT TO EXISTING DCW. FIELD VERIFY LOACTION.

3 CONNECT TO EXISTING DHW. FIELD VERIFY LOACTION.

4 CONNECT TO EXISTING SS. FIELD VERIFY LOACTION.

5 CONNECT TO EXISTING VENT. FIELD VERIFY LOACTION.

3" 1/2

1/2

1-1/2"

WB

WB

WASHER BOX

- 1/2" 1/2" 2" 2" 2" WHITE

SIOUX CHIEF

696-G2313XF- WATER HAMMER ARRESTOR

1/4 TURN VALVEPEX CRIMP CONNECTION

PLUMBING SCHEDULE

FIXTURE MANUFACTURER

MODEL NUMBER

FIXTURE ROUGH-IN SIZES

COLD HOT VENTTRAP

inches

WASTE

FINISH

ACCESSORIES AND COMMENTSTAG

FIXTURE TYPE

MOUNTING LOCATION DOMESTIC WATER WASTE & VENT COLOR

SCALE:

WASHING MACHINE BOX DETAILA NTS

1/2" HW

2" STANDPIPE

HOSE BIBS WITH

3" WASTE

2" VENT

WASHING

MACHINE BOX

1/2" CW

WATER HAMMER

VACUUM BREAKER

ARRESTOR (TYP)

AND P-TRAP

SHOWER

2"1/2" 1/2" 2"2" CHROME

SH

1 MOEN FAUCET (T8375)

-PEERLESS VALVE (PTR188700-UN)

SIOUX CHIEF FLOOR DRAIN(832-25PNRE)

WATER CLOSET

FLOOR MOUNT-TANK -1/2" WHITE2"- 4"

KOHLERWC

1 K-3979BEMIS WHITE SEAT (1955C) LEFT CHROME TRIP LEVER

PROFLO CHROME ESCUTCHEONBRASS CRAFT 1/4 TURN ANGLE STOP WITH SS SUPPLY HOSE

COUNTER MOUNT

LAVATORY-ADA

1-1/4"1/2" 1/2" 2"2" WHITE MOEN FAUCET (8800 CHROME)

KOHLERLAV

INSULATED P-TRAP COVER

PROFLO 1 1/4" SS GRID STRAINER AND P-TRAP

SIOUX CHIEF OXBOX (696-G2011XF), WATTS LFUSG-CS MIXING VALVE

K-2196-4

WATER CLOSET

FLOOR MOUNT-TANK -1/2" WHITE2"- 4"

KOHLERWC

2 K-3979BEMIS WHITE SEAT (1955C) RIGHT CHROME TRIP LEVER

PROFLO CHROME ESCUTCHEONBRASS CRAFT 1/4 TURN ANGLE STOP WITH SS SUPPLY HOSE

SCALE:

PLUMBING - DWVA 1/4" = 1'-0"

WB

SCALE:

PLUMBING - DWVB 1/4" = 1'-0"

1/2

1/2

WB

WC

WC

LAV

LAV

SH

SH

6 RELOCATE TOILET FLANGE FOR NEW LAYOUT

RELOCATE DCW TO WC FOR NEW LAYOUT

7 7

8 REMOVE DF AND CAP PIPES IN WALL

A&B P201

HB

HOSE BIBB / JS FAUCET

1/2" 1/2"

FIAT

-FIAT HOSE AND BRACKET (832-AA)

FIAT FAUCET (830-AA)

RP

HOT WATER RECIR. PUMP

- SUPPLY COMPANION FLANGES

1" THREADED UNION CONNECTION

006E3-- -- 3/4" -

ELECTRICAL – 115V / 1Ø / 60 (1/40 HP, 0.54 AMPS) - HARDWIRED

1 GPM @ 5 FEET OF HEAD, **AUTO SHUT OFF AND TIMER

TACO

**CONTROLS FOR CIRCULATING HOT WATER SYSTEM PUMPS SHALL AUTOMATICALLY TURN…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .