7-Attachmetn B - Fire Station 23 Rev. 08.19.26.pdf
PDF 3 MB Posted
- Solicitation number
- GJ27-18
- Issued by
- Summit County, Utah
About this file
This is a design and construction document set for Fire Station 23, an interior remodel and dorm addition project managed by the North Summit Fire District in Wanship, Utah (located in Summit County). The project involves a 1,850 square-foot interior remodel and the addition of three new sleeping rooms at the existing fire station located at 2000 South Hoytsville Road, Coalville, Utah 84017. Additional work includes upgrading lighting systems, replacing mechanical units, and general facility improvements to meet current building codes. The mandatory pre-proposal site visit is scheduled for August 27, 2026, with questions due by September 2, 2026 at 2:00 PM Mountain Time, and bid submissions due by September 4, 2026 at noon Mountain Time via the U3P portal. The project is designed to comply with the 2021 International Building Code, 2021 International Plumbing Code, 2021 International Mechanical Code, 2021 International Fire Code, 2020 National Electrical Code, 2021 International Energy Conservation Code, and ADA requirements.
The construction documents indicate the facility will be classified as Type IIB construction with an occupancy classification of B (administrative), S-2 (vehicles bay and storage), and R-2 (sleeping quarters). The building has an allowable height of 40 feet with a current height of 1 story. The remodel scope includes removal and replacement of plumbing fixtures, installation of new shower pans with FRP wall finishes, removal and upgrading of lighting fixtures throughout sleeping areas and common spaces, new HVAC mechanical units, removal of existing siding with installation of new hardboard siding and trim, replacement of overhead doors and window systems, and interior wall modifications to accommodate the new sleeping rooms. Specific document references include architectural plans (A101-A501), mechanical and plumbing plans (M201, P201), and electrical plans (E000-E601). The design team includes Alt Architecture as the architect, JTB Engineering for mechanical systems, and Rocky Mountain Consulting Engineers for electrical systems.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 3-Attachment C Cost Sheet.xlsx | XLSX spreadsheet | |
| 9-20250120 111534.jpg | JPG image | |
| 4-Attachment E.pdf | ||
| 12-Award Justification.pdf | ||
| 8-25042 - Wanship Fire Station 23 - ADD3.pdf | ||
| 6-Attachment A Standard Terms and Conditions GOODS AND SERVICES.docx | DOCX document | |
| 5-Attachment B2 - Westnet plans.pdf | ||
| 2-Staiton 23 RFP.pdf | ||
| 1-Attachment D Technical Evaluation Scoring Sheet.xlsx | XLSX spreadsheet | |
| 10-Pre-proposal Mtg Attendance Log ADA (1).docx | DOCX document | |
| 11-000 U3P Courtesy Posting Closed.pdf |
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT LOCATION
NOTES TO BIDDERS:
1. FURNITURE ARE FOR REFERENCE ONLY AND WILL BE OWNER
PROVIDED.
2. CONTRACTOR, SUBCONTRACTOR, VENDOR OR ANY OTHER
PERSON PARTICIPATING IN BIDDING THIS PROJECT SHALL BE
RESPONSIBLE FOR INFORMATION CONTAINED IN ANY AND ALL
SHEETS OF DRAWINGS AND SPECIFICATIONS.
JURISDICTION
SUMMIT COUNTY, UTAH
CODE
2021 INTERNATIONAL BUILDING CODE (IBC)
2021 INTERNATIONAL PLUMBING CODE (IPC)
2021 INTERNATIONAL MECHANICAL CODE (IMC)
2021 INTERNATIONAL FIRE CODE (IFC)
2020 NATIONAL ELECTRICAL CODE (NEC)
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2017 AMERICANS WITH DISABILITIES ACT (ADA) (ANSI A117.1)
OCCUPANCY (CH. 3)
OCCUPANCY: B ADMINISTRATIVE
S-2 VEHICLES BAY & STORAGE
R-2 SLEEPING QUARTERS
A ASSEMBLY (UNDER 100)
REQUIRED SEPARATION OF OCCUPANCIES (508.4)
NONE
TYPE OF CONSTRUCTION
IA IB IIA IIB IIIA IIIB IVA IVB VA VB
AUTOMATIC SPRINKLER SYSTEM
YES NO
BUILDING HEIGHT (504.3)
ALLOWABLE BUILDING HEIGHT ALLOWED ACTUAL
40'-0" EXISTING
NUMBER OF STORIES (504.4)
ALLOWABLE NUMBER OF STORIES 2 1
BUILDING AREA (506)
REMODEL 9,000 SF 1,850 SF
FIRE RESISTIVE REQUIREMENTS FOR IIB (TABLE 601)
PRIMARY STRUCTURAL FRAME 0 HR RATING
BEARING WALLS
EXTERIOR 0HR RATING
INTERIOR 0HR RATING
NON BEARING WALLS 0HR RATING
FLOOR CONSTRUCTION 0HR RATING
ROOF CONSTRUCTION 0HR RATING
EGRESS WIDTH (TABLE 1005.1)
OTHER EGRESS 0.2 INCHES PER OCCUPANT
PLUMBING FIXTURES
EXISTING WATER CLOSETS 2
EXISTING LAVATORIES 2
DRINKING FOUNTAINS 0
SERVICE SINKS 1
FIRE STATION 23 alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
DESIGN TEAM
OWNER
HENEFER FIRE STATION 22
TYLER ROWSER, ADMINISTRATIVE BATTALION CHIEF
ARCHITECT
alt architecture
1445 WEST 8660 SOUTH
WEST JORDAN, UTAH 84088
801-865-0633 andy@altarchitecture-ut.com
ANDY TONGISH, AIA
MECHANICAL
JTB ENGINEERING
922 W. BAXTER DRIVE, SUITE 100
SOUTH JORDAN, UTAH 84121
801-849-8590 jeff.brown@jtbengineering.net
JEFF BROWN, PE
ELECTRICAL
ROCKY MOUNTAIN CONSULTING ENGINEERS
2332 WEST 12600 SOUTH SUITE F
RIVERTON, UTAH 84065
801-566-0503 david@rmceut.com
DAVID STEWARD, PE
VICINITY MAPDRAWING INDEX
RENDERING
PROJECT SUMMARY
2000 SOUTH HOYTSVILLE ROAD COALVILLE, UTAH 84017
NORTH SUMMIT FIRE DISTRICT
CODE ANALYSIS
/1
/2
:3
:4
A M
C O
V
ER
S H
EE
T
25-001 act act
8/19/2026
COVER
SHEET
G001
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
DRAWING INDEX
SHEET # SHEET CONTENTS
GENERAL
G001 COVER SHEET
ARCHITECTURAL
A101 FLOOR PLAN
A102 REFLECTED CEILING PLAN & MISC.
A201 EXTERIOR ELEVATIONS
A401 INTERIOR ELEVATIONS
A501 MISC. DETAILS
SP1 SPECIFICATIONS
MECHANICAL
M001 TITLE SHEET (LEGEND & ABBREVIATIONS)
M201 MECHANICAL PLANS
P201 PLUMBING PLAN
ELECTRICAL
E000 ELECTRICAL GENERAL SHEET
E101 LIGHTING PLAN
E201 POWER PLAN
E601 ELECTRICAL SCHEDULES
8/19/2026
INTERIOR REMODEL ADDING 3 SLEEP ROOMS, UPGRADE LIGHTING, AND
MECHANICAL UNITS.
N
BENJAMIN NIELSON - FIRE CHIEF DATE
TYLER ROWSER - ADMINISTRATIVE BATTALION CHIEF DATE
8/14/2025 FOR BIDDING
4/27/2026 MOVED PATIO
TO WEST SIDE
8/19/2026 OWNER REVIEW
CHANGES
WD
REF.REF.
A201
/8
/4
/4
/8
EX
EX
REMOVE CARPET & PAD, &
BASE TO CONCRETE
THROUGHOUT THE
BUILDING. REMOVE GLUE.
A102
EX
W1
W1
W1
W1
W1
W1
F1
B1C1 W1W1
W1
W1
F1
B1C1 W1W1
W1
W1
F1
B1C1 W1W1
W1
F1
B1C1 W1
NO WORK IN THIS AREA
F2
B3C1 W1
EX
1/ A4
A201
EXISTING
ELECTRICAL PANEL
A201
A201
A
A
A
11' - 10"
W1
T
EXISTING ELECTRICAL PANEL
4/A401
A401
TYP
W1
W1
W1
SLEEPING 1
SLEEPING 2
SLEEPING 3
W1
F1
B1C1 W1W1
W1
OFFICE/SLEEPING 4
MECHANICAL
STORAGE
KITCHEN
RESTROOM
RESTROOM
EQUIPMENT BAY
WINDOW INFILL
SEE WALL TYPE W2
GROUP ROOM
8/A401
9/ A4
SHOWER SHOWER
13 13
4" CONCRETE STEP
@ FLOOR LEVEL
4" CONCRETE SLAB
ON 4" GRAVEL BASE @
GRADE - LEVEL w/
LANDSCAPING
NOTE:
PATCH & REPAIR LANDSCAPING
AROUND NEW CONCRETE PAD
SL
O
P E
SLOPE
/8
1' - 0"
5' - 6"
17' - 0"
SLOPE
W1
W1
W1
PARKING STRIPPING LAYOUT TO BE PROVIDED
BY OWNER, INSTALLED BY CONTRACTOR
3/ A4
12/A401
/A
13/A401
10/A401
4' - 0"
8' - 0"
EXISTING HOSE CONNECTION
EXISTING HOSE CONNECTION
R1
R1
R1
R1
R1
STACKED W & D
HOSE BIBB - TAP OFF
HOSE CONNECTION
PIPE
HOSE BIBB - TAP OFF HOSE
CONNECTION PIPE
REPLACE EXISTING PIPING
INTERIOR ELEVATIONS SIM.
4' - 0"
F2
B1C1 W1
W1
W1
W1
3 1
EX
EXTEND 4'-0" x 4'-0" DIAMOND PLATE
BEHIND FAUCET & HOSE CONNECTION
EXTEND 4'-0" x 4'-0" DIAMOND PLATE
BEHIND FAUCET & HOSE CONNECTION
PROVIDE PLASTIC HDPE BOLLARD
COVER OVER EXISTING STEEL
BOLLARD; COLOR TBD.
PROVIDE PLASTIC HDPE BOLLARD
COVER OVER EXISTING STEEL
BOLLARD; COLOR TBD.
PROVIDE PLASTIC HDPE BOLLARD
COVER OVER EXISTING STEEL
BOLLARD; COLOR TBD.
R1
KEYED NOTES
1 OWNER SHALL REMOVE ALL WALL ITEMS TO BE SAVED. THE CONTRACTOR
SHALL REMOVE ALL REMAINING ITEMS & PROPERLY DISPOSE OF ITEMS.
2 REMOVE WOOD TRIM IN SLEEPING QUARTERS, PATCH & REPAIR WALL
BEFORE PAINTING.
3 PATCH & REPAIR WALL AFTER DEMOLITION.
4 REMOVE EXISTING WINDOW SYSTEM, INFILL OPENING w/ MATCHING
THICKNESS MATERIAL.
5 REMOVE PORTION OF NON-BEARING WALL FOR NEW WINDOW SYSTEM.
6 REMOVE EXISTING WALL, DOOR & FRAME.
7 REMOVE EXISTING DOOR & FRAME. PATCH WALL w/ MATCHING THICKNESS
METAL STUDS & 5/8" TYPE 'X' GYPSUM BOARD EACH SIDE.
8 REMOVE EXISTING FOLDING PARTITION DOOR & FRAME, PATCH & REPAIR
WALL & CEILING
9 REMOVE EXISTING LIGHTS IN SLEEPING AREAS, KITCHEN, RESTROOMS &
GROUP ROOM, REFER TO REFLECTED CEILING PLAN & ELECTRICAL DWGS.
10 REMOVE EXISTING DRINKING FOUNTAIN PIPING, CAP PIPES BEHIND WALL.
PATCH & REPAIR GYPSUM BOARD IN THIS AREA.
11 EXISTING CEILING ACCESS TO REMAIN.
12 REMOVE FRP WALL FINISHES, SHOWER PAN AND PLUMBING FIXTURES.
INSTALL NEW SHOWER PAN, MATCHING DRAIN LOCATION, & FRP WALL
FINISH TO 8'-0".
13 REMOVE EXISTING PLUMBING FIXTURES. INSTALL NEW TOILET, & NEW SINK.
PROVIDE NEW PIPING AS NEEDED.
14 INSTALL NEW 1x4 SURFACE MOUNTED LED FIXTURE.
15 REMOVE COILING DOOR, FRAME, & HARDWARE.
16 PATCH & REPAIR DAMAGED CEILING.
17 ADJUSTABLE SHELVING: (5) 1" MELAMINE SHELVES, ROUNDED FRONT EDGE,
WALL BRACKET & SHELF SUPPORTS
TYPE
W1
FIRE RATING
FIRE TEST
HEIGHT
NONE
NONE
TO DECK ABOVE
INTERIOR FACE: 5/8" GYPSUM
BOARD
STRUCTURE: 2x4 WOOD STUD @ 16" oc
INTERIOR FACE: 5/8" GYPSUM
BOARD
TYPE
W2
FIRE RATING
FIRE TEST
HEIGHT
NONE
NONE
VERIFY OPENING
INTERIOR FACE: 5/8" GYPSUM
BOARD, ALIGN w/ EXISTING WALL
STRUCTURE: MATCH EXISTING
WALL THICKNESS
EXTERIOR: EIFS ON WEATHER
BARRIER ON SHEATHING
INSULATION: MATCH EXISTING
WALL THICKNESS - R19 MIN.
INSULATION: R13 BATT SOUND
INSULATION
GENERAL NOTES:
1. DO NOT SCALE DRAWINGS. WRITTEN DIMENSIONS SHALL HAVE PRECEDENCE. LARGER SCALE DRAWINGS SHALL HAVE PRECEDENCE OVER
SMALLER SCALE DRAWINGS. THE GENERAL CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY DIMENSION DISCREPANCIES OR
CONFLICTS BEFORE PROCEEDING WITH THAT PORTION OF WORK.
2. CONTRACTOR SHALL VERIFY LAY-OUT OF STRUCTURAL, MECHANICAL, AND ELECTRICAL.
3. ALL INTERIOR DIMENSIONS ARE TO/FROM FACE OF STUD / MASONRY. ALL EXTERIOR DIMENSIONS ARE TO/FROM FACE OF
GRID/FOUNDATION. DIMENSIONS MARKED 'CLEAR' OR 'CLR' ARE FROM FACE OF FINISH TO FACE OF FINISH AND SHALL BE MAINTAINED AND
CANNOT BE FIELD ADJUSTED WITHOUT PRIOR APPROVAL OF THE ARCHITECT.
4. ALL DOOR FRAMES SHALL BE 3" MIN. FROM WALL U.N.O.
5. BLOCKING TO BE PROVIDED FOR ALL WALL MOUNTED EQUIPMENT
6. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ALL WORK REGARDLESS OF THE LOCATION OF THE INFORMATION IN THE
DOCUMENTS. THE GENERAL CONTRACTOR SHALL UTILIZE THE COMPLETE & ENTIRE CONSTRUCTION DRAWINGS AND WRITTEN
SPECIFICATIONS FOR ALL REQUIRED INFORMATION TO PROVIDE COMPLETE CONSTRUCTION OF THIS PROJECT AND IS RESPONSIBLE TO
COORDINATE ALL DRAWINGS AND SPECIFICATIONS WITH ALL SUBCONTRACTORS REGARDLESS OF LOCATION IN CONTRACT DOCUMENTS.
ITEMS LISTED IN DRAWINGS MAY NOT BE INCLUDED IN SPECIFICATIONS. ITEMS LISTED IN SPECIFICATIONS MAY NOT BE INCLUDED IN
DRAWINGS.
7. THE GENERAL CONTRACTOR SHALL FIELD VERIFY ALL CONDITIONS AND DIMENSIONS PRIOR TO BEGINNING ANY WORK.
8. THE GENERAL CONTRACTOR IS TO CLARIFY WITH THE ARCHITECT ANY DISCREPANCIES DURING BIDDING AND PRIOR TO COMMENCING
WORK.
9. FOR CONSTRUCTION DETAILS NOT SHOWN, USE THE MANUFACTURER'S STANDARD DETAILS OR APPROVED SHOP DRAWINGS / DATA
SHEETS IN ACCORDANCE WITH THE PROJECT SPECIFICATIONS.
10. CONSTRUCTION SHALL CONFORM WITH ANSI A-117.1-2009, AND THE AMERICANS WITH DISABILITIES ACT (ADA).
11. THE GENERAL CONTRACTOR SHALL PROVIDE AND IS SOLELY RESPONSIBLE AND LIABLE FOR PUBLIC AND EMPLOYEE PROTECTION AS
NECESSARY AND AS REQUIRED BY THE CODES, INCLUDING EXTERIOR AND INTERIOR PEDESTRIAN TRAFFIC BARRIERS. ALL WORK SHALL
CONFORM TO THE ORDINANCES AND REGULATIONS OF GOVERNMENTAL AGENCIES HAVING JURISDICTION AT THE PROJECT.
12. THE GENERAL CONTRACTOR SHALL PROVIDE TEMPORARY BARRICADES FOR DUST AND NOISE CONTROL, AND ALL REQUIRED
ENVIRONMENTAL PROTECTION WHERE WORK JOINS EXISTING CONDITIONS.
13. ALL PENETRATIONS THROUGH ANY SURFACE SHALL BE THOROUGHLY SEALED WITH APPROPRIATE SEALANT MATERIAL.
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
/1
/2
:3
:4
A M
FL
O
O R
P
LA
N
25-001 act act
8/19/2026
FLOOR PLAN
A101
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
1/4" = 1'-0"A101
1 FLOOR PLAN
PROJECT NORTH
N
TRUE NORTH
DOOR SCHEDULE
MARK
LEAF SIZE
DOOR TYPE THICKNESS CONST. FINISH GLASS RATING
FRAME
TYPE
HARDWARE
GROUP KEYNOTEW H
1 3' - 0" 7' - 0" WD01 1 3/4" STAIN N N A -
2 3' - 0" 7' - 0" HM01 1 3/4" PAINT Y 45 EX -
3 3' - 0" 7' - 0" HM02 1 7/8" PAINT N 45 A
4 3' - 0" 7' - 0" AL01 1 3/4" - Y N
5 10' - 0" 12' - 0" AL04 1 1/2" STEEL Y N - - SEE NOTE CONCERNING
OH DOORS
EX 3' - 0" 7' - 0" <varies> 1 3/4" PAINT N <varies> <varies>
8/19/2026
N
8' - 0"
8' - 0"
8' - 0"
EXISTING FASCIA & SOFFIT
ALL NEW WALLS TO
EXTEND TO EXISTING
CEILING GYPSUM BOARD
PATCH & REPAIR GYPSUM
BOARD CEILING AFTER WALL
DEMOLITION
3' - 0"
3' - 0"
NOTE:
LIGHT LAYOUT IS TYPICAL
EACH SLEEPING ROOM
EXISTING VENTS
DEMOLITION NOTE
CONTRACTOR SHALL REMOVE LIGHT
FIXTURE IN SLEEP/OFFICE, RESTROOMS,
KITCHEN, & GROUP ROOM. REPLACE w/
NEW FIXTURES PER ELECTRICAL
DRAWINGS.
EXISTING FASCIA & SOFFIT
EXISTING FASCIA & SOFFIT
SEE A101 FOR KEYED NOTES
SLEEPING 1
SLEEPING 2
SLEEPING 3
DOWNLIGHTS - TYP
F.V.
F.V.
F.V.
REFER TO ELECTRICAL PLANS FOR LIGHTING LAYOUT
NOTE:
2x @ 16" o.c. EXT. WALL. GC TO VERIFY
SHEATHING IS NAILED TO STUDS AT 6"
O.C. EDGE AND 12" O.C. FIELD AFTER
SIDING IS REMOVED & WHERE
POSSIBLE.
". (E) ANCHOR BOLTS TO BE 1/2" DIA.
(MIN.), SPACED NO FURTHER THAN 6'-0"
APART (PER IBC 2308.3.1). NOTIFY EOR
IF OTHERWISE"
(2) 2x6 HEADER w/ (2) STUDS
BOTH SIDES (1) JACK, (1) KING
(2) 2x6 HEADER w/ (2) STUDS
BOTH SIDES (1) JACK, (1) KING
(2) 2x6 HEADER w/ (2) STUDS
BOTH SIDES (1) JACK, (1) KING
A501
BASE
W1 @ 16" oc w/ 5/8" GYP. BD.
EACH SIDE w/ 3 1/2" THICK
SOUND INSULATION
TYP.
EXISTING
CEILING
SLEEPING
GROUP ROOM
WOOD DOOR
HM FRAME
PROVIDE BLOCKING AS
NEEDED FOR WALL SUPPORT
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
/1
/2
:3
:4
A M
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
M
IS
C
25-001 act act
8/19/2026
REFLECTED
CEILING PLAN &
MISC.
A102
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
1/4" = 1'-0"A102
1 REFLECTED CEILING PLAN
1/8" = 1'-0"A102
2 STRUCTURAL PAN
3/8" = 1'-0"A102
3 SECTION
FLOOR PLAN
100' - 0"
EXISTING SOFFIT & FASCIA
NEW ALUMINUM WINDOW SYSTEM
EXISTING GAS METER
EXISTING ELECTRICAL EQUIPMENT
MATCH EXISTING VENT
ALUMINUM
STOREFRONT DOOR
SYSTEM
IN-FILLED WINDOW LOCATION
MATCH EXISTING VENT
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
FLOOR PLAN
100' - 0"
EXISTING WINDOW SYSTEM
EXISTING SOFFIT & FASCIA
EXISTING HM DOOR & FRAME
PAINT
A501
TYP
REMOVE EXISTING SIGNAGE
NEW SIGNAGE INSTALLED BY OWNER
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
FLOOR PLAN
100' - 0"
EXISTING WINDOW SYSTEM
EXISTING SOFFIT & FASCIA
A501
IN-FILL WINDOW LOCATION
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
FLOOR PLAN
100' - 0"
EXISTING SOFFIT & FASCIA
EXISTING OVERHEAD DOORS TO BE REMOVED
INSTALL NEW OH DOORS & SYSTEM
MATCH EXISTING VENT
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING & TRIM
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
/1
/2
:3
:4
A M
EX
TE
R
IO
R E
LE
V
A
TI
O N
S
25-001 act act
8/19/2026
EXTERIOR
ELEVATIONS
A201
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
1/4" = 1'-0"A201
1 NORTH ELEVATION
1/4" = 1'-0"A201
3 EAST ELEVATION
1/4" = 1'-0"A201
4 WEST ELEVATION
1/4" = 1'-0"A201
2 SOUTH ELEVATION
IN-FILLED DOOR OPENING
16 ga. DIAMOND PLATE
PAINTABLE - TYP. ALL 4 WALLS
EXISTING ELECTRICAL PANEL
EXISTING ELECTRICAL PANEL
REMOVE MOUNTED ITEMS
COVED EPOXY BASE
A401
A401
A401
OFFICE/SLEEPING 4 = 5'-6" F.V.
2'-9" F.V. 3' - 0" 3' - 0" 3' - 0"
SCHEDULED CEILING
PLASTIC LAMINATE
CASEWORK
BASE
CLEAT - PAINT
1" MELAMINE
ADJUSTABLE SHELVING
PROVIDE SUPPORTS AS
NEEDED
EXISTING CEILING
UPGRADED LIGHT FIXTURE
BASE - BY OWNER
SCHEDULED WALL
4" SS HANDLE
PLASTIC LAMINATE DOOR
MELAMINE INTERIOR
(4) 3/4" MELAMINE SHELF
(ADJUSTABLE)
2x4 BASE
3/4" MELAMINE SHELF
(FIXED)
1" DIVIDER - FULL HEIGHT
KEY LOCK EACH DOOR
1' - 10"
1'
- 7
4" SS HANDLE
PLASTIC LAMINATE DOOR
MELAMINE INTERIOR
3/4" MELAMINE SHELF
(FIXED)
2x4 BASE
1" ROD
3/4" MELAMINE SHELF
(FIXED)
KEY LOCK EACH DOOR
1'
- 7
1' - 10"
LINE OF CASEWORK BEYOND
3/16" x 1" BRACKET
PAINT
PLASTIC LAMINATE COUNTERTOP
w/ ROUNDED EDGE
BLOCKING AS REQUIRED
3' - 0" 3" F.V.
F.V.
1' - 0" 3' - 0" 3' - 0"
3' - 0"1' - 6"
F.V.
2' - 2 1/2"3' - 6"1' - 6"
FILLER PANEL
2'
1'
- 6
PLASTIC LAMINATE CASEWORK
w/ ADJ. SHELF
PLASTIC LAMINTE CASEWORK
w/ ADJ. SHELF
PLASTIC LAMINATE
COUNTERTOP & SPLASH
DOUBLE STAINLESS STEEL KITCHEN SINK
GOOSE NECK FAUCET, BLADE HANDLES
EXISTING
WINDOW
SYSTEM
NOTE:
PROVIDE FE ON ALL EXPOSED
CASEWORK
R1
3' - 0" 2' - 8" 1' - 0"
1'
- 6
2'
1'
- 6
PLASTIC LAMINATE CASEWORK
w/ ADJ. SHELF
PLASTIC LAMINTE CASEWORK
w/ ADJ. SHELF
PLASTIC LAMINATE
COUNTERTOP & SPLASH
NOTE:
PROVIDE FE ON ALL EXPOSED
CASEWORK
3' - 0" 3' - 0"
WALL - PAINT
EPOXY COVED BASE
PLASTIC LAMINATE CASEWORK
CENTER 1" SHELF FIXED
3 ADJUSTABLE SHELVES
WALL - PAINT
1' x 2' WALL TILE
EPOXY COVED BASE 4
2'
FIXTURE
1' x 2' WALL TILE
EPOXY COVED BASE
WALL - PAINT
SCHEDULED DOOR
& FRAME
1' - 6"
2' x 3' MIRROR
FIXTURE
WALL - PAINT
1' x 2' WALL TILE
EPOXY COVED BASE
1' x 2' WALL TILE
EPOXY COVED BASE
WALL - PAINT
CLEAR
3' - 0" MIN
CULTURED MARBLE SHOWER INSERT (3
SIDES) & ADA SHOWER PAN
w/ HAND-HELD SHOWER HEAD & TRACK
SLIDE, PROVIDE FOLDING SHOWER SEAT
MOUNTING PER ADA REQUIREMENTS,
VERIFY EXISTING DRAIN LOCATION
1' - 6"
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
/1
/2
:3
:4
A M
IN
TE
R
IO
R E
LE
V
A
TI
O N
S
25-001 act act
8/19/2026
INTERIOR
ELEVATIONS
A401
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
1/4" = 1'-0"A401
1 BAY ELEVATION
1/4" = 1'-0"A401
4 CASEWORK ELEVATION
3/8" = 1'-0"A401
2 STORAGE SECTION
3/4" = 1'-0"A401
6 CASEWORK SECTION (LEFT)
3/4" = 1'-0"A401
5 CASEWORK SECTION (RIGHT)
3/4" = 1'-0"A401
7 WORK DESK
1/4" = 1'-0"A401
8 KITCHEN ELEVATION 1
1/4" = 1'-0"A401
9 KITCHEN ELEVATION 2
8/19/2026
1/4" = 1'-0"A401
10 KITCHEN ELEVATION 3
KING STUD QUANTITIES
(10' MAX HEIGHT)
PLACE STUD AT TOP PLATE
SPLICE
DOUBLE TOP PLATE TO MATCH
STUD DEPTH
CRIPPLE STUDS @ 16" O.C.
HEADER TO TOP PLATE
KING STUD PER SCHED.
ATTACH TO JACK STUD W/ 16d @
12" O.C., STAGGERED
JACK STUD
HEADER
(MAY BE HELD UP AS DESIRED)
2X PLATE
2X PT SILL PLATE ON CONCRETE
2X SILL PLATE WHEN BEARING
ON WOOD
INTERIOR OPENINGS 1 KING STUD (MIN)
EXTERIOR OPENINGS <= 3'-6"
EXTERIOR OPENINGS > 3'-6" AND < 9'-0"
1 KING STUD (MIN)
2 KING STUD (MIN)
EXTERIOR OPENINGS > 9'-0" AND <= 15'-0" 3 KING STUD (MIN)
4 KING STUD (MIN)EXTERIOR OPENINGS > 15'-0" AND <= 21'-0"
WOOD STUD
HEADER
PAINTED HOLLOW METAL
FRAME
DOOR AS
SCHEDULED
CONT. SEALANT, BOTH
SIDES TYP.
2"
SEE WALL TYPES
(2) 2x6 HEADER w/ (2) STUDS
BOTH SIDES (1) JACK, (1) KING
FLASHING
SIDING - SEE ELEVATIONS
NEW 2x PLATE
ALUMINUM SLIDING WINDOW
CULTURED WINDOW SILL
ALL NEW & EXISTING WINDOWS
EXISTING FRAMED WALL
SCHEDULE
SEE
SC
H
E D
U
LE
SE
E
WD01
SOLID CORE WOOD
STAIN
DOOR AND WINDOW GENERAL NOTES
1. PROVIDE SEALANT @ JOINTS AT DISSIMILAR MATERIAL
CONNECTIONS, ISOLATE DISSIMILAR METALS.
2. ALL DIMENSIONS FOR DOOR & WINDOW OPENINGS TO BE
FIELD VERIFIED PRIOR TO MANUFACTURING & INSTALLATION.
GLAZING NOTES:
1. ALL GLAZING PANEL MEETING ALL OF THE FOLLOWING CRITERIA TO BE
SAFETY GLAZING COMPLYING w/ ALL APPLICABLE BUILDING CODES:
a) PANEL IS GREATER THAN 9 S.F.
b) PANEL IS WITHIN 18 INCHES OF FINISH FLOOR
c) PANEL IS GREATER THAN 60 INCHES ABOVE FINISH FLOOR
d) PANEL IS NEAR A WALKING PATH OR AREA
2. ALL SAFETY GLAZING TO HAVE PERMANENT LABELS/IDENTIFICATION
LOCATED ON GLAZING.
# GLASS TYPE SCHEDULE
1 1" GLASS, DOUBLE PANE
2"
SE
E S
C H
E D
U
LE
2"
SCHEDULE
SEE 2"
A501
A501
A
METAL HOLLOW
PAINT
FLOOR LEVEL
SLIDE
4' - 0"
AL01
ALUMINUM FRAME
SCHEDULE
SEE
SC
H
E D
U
LE
SE
E
HM01
HOLLOW METAL
PAINT
6" 2' - 0" 6"
SCHEDULE
SEE
SC
H
E D
U
LE
SE
E
HM02
HOLLOW METAL
PAINT
2"
SE
E S
C H
E D
U
LE
2"
SCHEDULE
SEE 2"
B
ALUMINUM
FINISH LEGEND
WALLS
W1 - PAINTED GYPSUM
MANUF: SHERWIN WILLIAM PROMAR 200
COLOR: TBD
FINISH: SEMI-GLOSS (PRIMER + 2 COATS)
W2 - FIBERGLASS REINFORCED PANEL
MANUF:
COLOR: WHITE
FINISH: 8'-0" HIGH, EMBOSSSED w/ EDGE TRIM
BASE
B1 - BASE
BY OWNER, INSTALLED BY OWNER
B2 - RUBBER BASE
MANUF: ROPPE
COLOR: MATCH EXISTING
FINISH: COVED
B3 - EPOXY COVED
COLOR: MATCH FLOORING
FINISH: 4" COVED
CEILING
C1 - EXISTING PAINTED GYPSUM
MANUF: SHERWIN WILLIAMS PROMAR 200
COLOR: TBD
FINISH: FLAT
FLOORS
F1- CARPET
BY OWNER, INSTALLED BY OWNER
F2 - EPOXY FLOORING
WALL
WALL
WALL
WALL
FLOOR
BASE
CEILING
MISC. COLORS
HOLLOW METAL FRAMES
MANUF: SHERWIN WILLIAMS
COLOR: TBD
FINISH: LATEX SEMI-GLOSS (2 COATS)
WOOD DOORS
COLOR: TBD
FINISH: STAIN
DOOR HARDWARE
COLOR: BRUSHED NICKEL
R1 - 2" PVC HORIZONTAL BLINDS
COLOR TO BE DETERMINED
WAND TILT & CORD LIFT
FURNISH ALL REQUIRED MOUNTING
HARDWARE
EXISTING WALL
REMOVE EXISTING
SIDING TO SHEATHING
SANDSTONE NATURAL STONE
3" EIFS
WEATHER BARRIER
PERIMETER FLASHING,
PRE-FINISHED, COLOR TBD
EXISTING WALL
REMOVE EXISTING
SIDING TO SHEATHING
EXISTING WINDOW SYSTEM
WEATHER BARRIER
PERIMETER FLASHING,
PRE-FINISHED, COLOR TBD
REMOVE EXISTING HORIZONTAL SIDING
INSTALL NEW HARD BOARD SIDING
EXISTING WALL
WEATHER BARRIER
1/2"
1"
3" EIFS MATERIAL
EXISTING WALL
WEATHER BARRIER
3" EIFS MATERIAL
METAL FLASHING
EXISTING FOUNDATION
2" GRADE - SLOPED
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
/1
/2
:3
:4
A M
M
IS
C . D
ET
A
IL
S
25-001 act act
8/19/2026
MISC. DETAILS
A501
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
3" = 1'-0"A501
3 HM DOOR HEAD/JAMB DETAIL
3/4" = 1'-0"A501
6 WINDOW HEAD/SILL
1/4" = 1'-0"A501
8 DOOR & WINDOW TYPES
1 1/2" = 1'-0"A501
1 EIFS TO STONE
1 1/2" = 1'-0"A501
2 EX WINDOW TO SIDING
3" = 1'-0"A501
4 EIFS V GROOVE
3" = 1'-0"A501
5 EIFS TO FOUNDATION
3/4" = 1'-0"A501
7 FRAMING DETAIL
085113 - ALUMINUM WINDOWS
PRODUCT
A. Manufacturers:
Kawneer Company Inc.
Series: slider
3-1/4" frame depth
B. Others:
1. UPON APPROVAL FROM THE ARCHITECT.
MATERIALS
A. Aluminum Extrusions: Alloy and temper recommended by aluminum window manufacturer for strength, corrosion resistance, and application of required finish and not less than 0.070" wall thickness at any location for the main frame and sash members.
B. Thermal Barrier: The thermal barrier shall consist of integral structural thermal break made with glass-reinforced nylon strips installed continuously and mechanically bonded to the aluminum.
C. Fasteners: Aluminum, nonmagnetic stainless steel or other materials to be non-corrosive and compatible with aluminum window members, trim, hardware, anchors, and other components.
D. Anchors, Clips, and Accessories: Aluminum, nonmagnetic stainless steel, or zinc-coated steel or iron complying with ASTM B633 for SC3 severe service conditions; provide sufficient strength to withstand design pressure indicated.
E. Reinforcing Members: Aluminum, nonmagnetic stainless steel, or nickel/chrome-plated steel complying with ASTM B456 for Type SC3 severe service conditions, or zinc-coated steel or iron complying with ASTM
B633 for SC3 severe service conditions; provide sufficient strength to withstand design pressure indicated.
Sealant: For sealants required within fabricated windows, provide window manufacturer's standard, permanently elastic, non-shrinking, and nonmigrating type recommended by sealant manufacturer for joint size and movement.
WINDOW SYSTEM
A. Slider
GLAZING
A. refer to drawings
HARDWARE
A. Provide manufacturer's standard hardware fabricated from aluminum, stainless steel, or other corrosion-resistant material compatible with aluminum; designed to smoothly operate, tightly close, and securely lock aluminum windows, and sized to accommodate sash weight and dimensions.
ACCESORIES
A. Stainless Steel Limit Arm with Key Release
B. Framing system gaskets, sealants, and joint fillers as recommended by manufacturer for joint type.
C. Sealants and joint fillers for joints at perimeter of window system.
D. Perimeter Anchors: When steel anchors are used, provide insulation between steel material and aluminum material to prevent galvanic action.
E. Insect Screens: (Full Screen) Field-mounted on interior with steel spring clips; handle-access wickets Black;
3/4" x 1-1/8" x .050" extruded tubular aluminum frame with finish to match window in color and performance; corners mitered, gusset reinforced, and crimped; 18 x 16 dark fiberglass; PVC splines.
F. Thermally Broken Construction: Fabricate aluminum windows with an integral, concealed, low-conductance thermal barrier. Thermal barriers shall be designed in accordance with AAMA TIR A8.
ALUMINUM FINISHES
A. Architectural Class II Clear Anodic Coating (Color #17 Clear) (Standard).
08200 - WOOD DOORS
PRODUCT
A. Manufacturer
1. Oshkosh Architectural Door Company
B. Others:
1. UPON APPROVAL FROM THE ARCHITECT.
MATERIALS
All stile and rail dimensions given are minimum sizes allowed after trimming to book size or factory prefitting.
A. Cores - SOLID CORE
Acoustical Door -
Doors are to be 1 3/4” thick and tested as an operable unit in accordance with ASTME90 and
ASTME 4l3. Stiles shall be same specie lumber as face veneer and rails mill option hardwood or SCL.
Sound Transmission Class: STC 44
B. PAINT GRADE
Doors with Opaque Finish -
Doors shall have medium density overlay faces meeting Government standards PSI74. Overlay shall be readily sandable, weatherproof, and carry a Class “B” Fire Rating. Paint grade Birch or hardboard shall not be considered as meeting this specification.
C. MISC.
Doors shall be suitable for hanging on full mortised butt hinges using No. 12 x 1 ¼” steel threaded-to-the head wood screws of the cadmium plated or rust resistant type. Half-surface hinges are not acceptable.
064116 - PLASTIC-LAMINATED-FACED ARCHITECTURAL CABINETS
PART 1 - SUMMARY
SECTION INCLUDES:
A. PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS.
B. SHOP DRAWINGS: SHOW LOCATION OF EACH ITEM, DIMENSIONED PLANS AND
ELEVATIONS, LARGE-SCALE DETAILS, ATTACHMENT DEVICES, AND OTHER COMPONENTS.
PART 2 - PRODUCTS
PLASTIC-LAMINATE-FACED ARCHITECTURAL CABINETS
A. QUALITY STANDARD: UNLESS OTHERWISE INDICATED, COMPLY WITH THE
"ARCHITECTURAL WOODWORK STANDARDS" FOR GRADES OF ARCHITECTURAL PLASTIC-
LAMINATE CABINETS INDICATED FOR CONSTRUCTION, FINISHES, INSTALLATION, AND OTHER
REQUIREMENTS.
B. GRADE: CUSTOM.
C. TYPE OF CONSTRUCTION: FACE FRAME.
D. CABINET, DOOR, AND FRONT INTERFACE STYLE: FLUSH OVERLAY.
E. HIGH-PRESSURE DECORATIVE LAMINATE: NEMA LD 3, GRADES AS INDICATED OR IF NOT
INDICATED, AS REQUIRED BY WOODWORK QUALITY STANDARD.
F. HORIZONTAL SURFACES: GRADE HGS.
G. EDGES: ABS/PVC EXTRUDED FABRICATION.
H. MATERIALS FOR SEMIEXPOSED SURFACES:
1. SURFACES: HIGH-PRESSURE DECORATIVE LAMINATE, NEMA LD 3, GRADE VGS
I. COMPOSITE WOOD PRODUCTS: PRODUCTS SHALL BE MADE WITHOUT UREA
FORMALDEHYDE.
J. THERMOSET DECORATIVE PANELS (MELAMINE): PARTICLEBOARD OR MEDIUM-DENSITY
FIBERBOARD FINISHED WITH THERMALLY FUSED, MELAMINE-IMPREGNATED DECORATIVE
PAPER AND COMPLYING WITH REQUIREMENTS OF NEMA LD 3, GRADE VGL.
K. CABINET HARDWARE AND ACCESSORIES
1. SEMICONCEALED HINGES FOR FLUSH DOORS: BHMA A156.9, B01361.
2. SEMICONCEALED HINGES FOR OVERLAY DOORS: BHMA A156.9, B01521.
3. HINGES IN "FRAMELESS CONCEALED HINGES (EUROPEAN TYPE)"
4. BACK-MOUNTED PULLS: BHMA A156.9, B02011.
5. WIRE PULLS: BACK MOUNTED, SOLID METAL, 4 INCHES LONG, 5/16 INCH
IN DIAMETER.
6. CATCHES: MAGNETIC CATCHES, BHMA A156.9, B03141.
7. ADJUSTABLE SHELF STANDARDS AND SUPPORTS: BHMA A156.9, B04071; WITH
SHELF RESTS, B04081
8. DOOR LOCKS: BHMA A156.11, E07121.
9. DOOR SILENCERS: BHMA A156.16, L03011.
ADJUSTING AND CLEANING
A. REPAIR DAMAGED AND DEFECTIVE CABINETS, WHERE POSSIBLE, TO ELIMINATE
FUNCTIONAL AND VISUAL DEFECTS; WHERE NOT POSSIBLE TO REPAIR, REPLACE
WOODWORK. ADJUST JOINERY FOR UNIFORM APPEARANCE.
B. CLEAN, LUBRICATE, AND ADJUST HARDWARE. CLEAN CABINETS ON EXPOSED AND
SEMIEXPOSED SURFACES. CLEAN DECORATIVE PLASTIC LAMINATE SURFACES
ACCORDING TO MANUFACTURER'S WRITTEN CARE AND MAINTENANCE INSTRUCTIONS.
PROTECT COMPLETED WORK FROM DAMAGE FOR DURATION OF CONSTRUCTION PERIOD.
0074646 - FIBER-CEMENT SIDING
PART 1 GENERAL
SECTION INCLUDES
A. FACTORY-FINISHED FIBER CEMENT LAP SIDING, PANELS, TRIM, AND ACCESSORIES.
SUBMITTALS
A. PRODUCT DATA: MANUFACTURER'S DATA SHEETS ON EACH PRODUCT TO BE USED, INCLUDING:
1. PREPARATION INSTRUCTIONS AND RECOMMENDATIONS.
2. STORAGE AND HANDLING REQUIREMENTS AND RECOMMENDATIONS.
3. INSTALLATION METHODS.
B. SELECTION SAMPLES: FOR EACH FINISH PRODUCT SPECIFIED, TWO COMPLETE SETS OF COLOR
CHIPS REPRESENTING MANUFACTURER'S FULL RANGE OF AVAILABLE COLORS AND PATTERNS.
WARRANTY
A. PRODUCT WARRANTY: LIMITED, NON-PRO-RATED PRODUCT WARRANTY.
1. PANELS FOR 30 YEARS.
B. FINISH WARRANTY: LIMITED PRODUCT WARRANTY AGAINST MANUFACTURING FINISH DEFECTS.
1. WHEN USED FOR ITS INTENDED PURPOSE, PROPERLY INSTALLED AND MAINTAINED
ACCORDING TO PUBLISHED INSTALLATION INSTRUCTIONS, FOR A PERIOD OF 15 YEARS
FROM THE DATE OF PURCHASE: WILL NOT PEEL; WILL NOT CRACK; AND WILL NOT CHIP.
FINISH WARRANTY INCLUDES THE COVERAGE FOR LABOR AND MATERIAL.
C. WORKMANSHIP WARRANTY: APPLICATION LIMITED WARRANTY FOR 2 YEARS.
PART 2 PRODUCTS
MANUFACTURERS
A. ACCEPTABLE MANUFACTURER: JAMES HARDIE BUILDING PRODUCTS, INC.,
B. SUBSTITUTIONS: APPROVED EQUAL.
SIDING AND TRIM
1. FIBER-CEMENT SIDING - COMPLIES WITH ASTM C 1186 TYPE A GRADE II.
2. TYPE: SMOOTH 7-1/4 INCHES (184 MM) WITH 6 INCHES EXPOSURE.
3. TRIM ACCESSORIES PER MANUFACTURER.
FINISHES
A. FACTORY PRIMER: PROVIDE FACTORY APPLIED UNIVERSAL PRIMER.
1. PRIMER: FACTORY PRIMED.
PART 3 EXECUTION
A. DO NOT BEGIN INSTALLATION UNTIL THE SUBSTRATES HAVE BEEN PROPERLY PREPARED.
B. INSTALL RESISTIVE BARRIERS OR VAPOR BARRIERS.
1. INSTALL WATER-RESISTIVE BARRIERS AND CLADDINGS TO DRY SURFACES.
2. REPAIR ANY PUNCTURES OR TEARS IN THE WATER-RESISTIVE BARRIER PRIOR TO THE
INSTALLATION OF THE SIDING.
3. PROTECT SIDING FROM OTHER TRADES.
PREPARATION
A. FOLLOW ALL MANUFACTURER REQUIREMENTS.
PROTECTION
A. PROTECT INSTALLED PRODUCTS UNTIL COMPLETION OF PROJECT.
B. TOUCH-UP, REPAIR OR REPLACE DAMAGED PRODUCTS BEFORE SUBSTANTIAL COMPLETION.
08100 - STANDARD HOLLOW METAL DOORS & FRAMES
Product
A. Manufacturer
1. APPROVED BY ARCHITECT
Materials
A. All steels used to manufacture doors, frames, anchors, and accessories shall meet at least one or more of the following requirements:
1. Cold rolled steel shall conform to ASTM designations A1008, Standard Specification for Steel Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength
Low-Alloy with Improved Formability and A568, Standard Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General
Requirements for.
2. Hot rolled, pickled and oiled steel shall comply with ASTM designations A1011, Standard
Specification for Steel, Sheet and Strip, Hot-Rolled, Carbon, Structural, High-Strength
Low-Alloy and High-Strength Low-Alloy with Improved Formability and A568, Standard
Specification for Steel, Sheet, Carbon, Structural, and High-Strength, Low-Alloy, Hot-Rolled and Cold-Rolled, General Requirements for.
3. Hot dipped zinc coated steel shall be of the alloyed type and comply with ASTM designations A924, Standard Specification for General Requirements for Steel Sheet, Metallic Coated by the Hot-Dip Process and A653, Standard Specification for Steel Sheet, Zinc Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip
Process.
B. Frames
1. Exterior frames
a. Level 2 for door model 2 0.053″ (1.3mm) minimum steel thickness for frames.
b. Frames shall be full profile weld type.
c. Provide frames with a minimum of three anchors per jamb suitable for the adjoining wall construction. Provide anchors of not less than 0.042″ (1.0 mm) in thickness or 0.167″ (4.2 mm) diameter wire.
d. All frames shall be fully prepared for all mortise template hardware and reinforced only for surface mounted hardware. Drilling and/or tapping shall be completed by others.
C. Doors
1. Doors shall meet at least one or more of the following requirements:
a. Level 2 – Heavy duty 1-3/4″ (44.5 mm)
Model 2 – Seamless
D. Door and panel construction
1. Face steel sheet shall meet the following requirements:
a. Level 2 - Model 2 – 0.042″ (1.0mm) minimum thickness
b. End closure: The top and bottom of the doors shall be closed with flush channels or closures. The channels or closures shall have a minimum material thickness of 0.042″ (1.0mm).
c. Core: See ANSI/SDI A250.8, Specifications for Standard Steel Doors and
Frames (SDI 100), Section 2.3.2.
d. Door edge design: See ANSI/SDI A250.8, Specifications for Standard Steel
Doors and Frames (SDI-100), Section 2.3.1.3.
E. Finishing
A. Prime finish: Doors and frames shall be thoroughly cleaned, and chemically treated to insure maximum paint adhesion. All surfaces of the door and frame exposed to view shall receive a factory applied coat of rust inhibiting primer, either air-dried or baked-on. The finish shall meet the requirements for acceptance stated in ANSI/SDI A250.10 Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and
Frames.
B. Design clearances
1. The clearance between the door and frame head and jambs shall be 1/8″ (3.2 mm)
2. The clearance at the bottom shall be 5/8″ (15.8 mm).
HARDWARE SETS
SET #1.0
NOT USED
SET #2.0
NOT USED
SET #3.0
NOT USED
SET #4.0
DOORS: 1, 2, 3, 5
3 BUTT HINGE FBB179 4.5" X 4.5" 26D ST
1 PRIVACY SET 9K3-0LL15D 626 BE
1 DOOR CLOSER EHD9016 AF90 DA AVB 689 BE
1 OVERHEAD STOP 9024 RA US32D AB
1 KICK PLATE K050 10" X 2" LDW B4E CSK 630 AB
1 GASKETING 5050 B-17 17' NA
1 AUTO DOOR BOTTOM 420NA NA
SET #5.0
DOORS: 4
3 BUTT HINGE FBB179 4.5" X 4.5" 26D ST
1 PRIVACY SET 9K3-0L15D 626 BE
1 DOOR CLOSER EHD9016 AF90 DA AVB 689 BE
1 OVERHEAD STOP 9024 RA US32D AB
1 KICK PLATE K050 10" X 2" LDW B4E CSK 630 AB
1 GASKETING 5050 B-17 17' NA
SET #6.0
NOT USED
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt a rc h it e c tu re
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
ANDY TONGISH 801-865-0633
TI
TL
E
P R
O
JE
C T
C
LI
EN
T
A D
D R
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
/1
/2
:3
:4
A M
SP
EC
IF
IC
A
TI
O N
S
25-001 act act
8/19/2026
SPECIFICATIONS
SP1
W A
N
SH
IP
F
IR
E
ST
A
TI
O
N
N O
R
TH
S U
M M
IT
F
IR
E
D
EP
A R
TM
EN
T
S O
U
TH
H O
Y
TS
V
IL
LE
R
O A
D C
O A
LV
IL
LE
, U
TA
H
8/19/2026
GENERAL NOTES:
PAINT
GARAGE PAINT INCLUDES ALL TRIM, WALLS, AND CEILINGS WILL BE THE SAME COLOR AND
SHEEN. INCLUDES:
1. PROTECT ALL ADJACENT SURFACES.
2. REPAIR MINOR IMPERFECTIONS.
3. APPLY STAIN BLOCKING PRIMER.
4. APPLY (2) COATS OF FINISH PAINT.
OVERHEAD DOORS
REMOVE AND REPLACE GARAGE DOORS. PROVIDE (3) HAAS CHT710 STEELBACK INSULATED
DOORS WITH VISION PANELS,
INCLUDES LIFTMASTER OPERATORS, INCLUDES RED/GREEN STOP LIGHTS, SEE ELECTRICAL.
APPARATUS BAY LIGHTING
DEMO OLD LIGHT FIXTURES. INSTALL NEW LED 200 WATT HIGH BAY LIGHTS (10). WIRING TO
EACH LIGHT.
FLOORING
EPOXY FULL FLAKE SYSTEM IN
KITCHEN, BATHROOM, LAUNDRY, AND DINING.
GARAGE EPOXY FLOOR SYSTEM
APLYING A POLYASPARTIC COATING SYSTEM TO THE GARAGE. INCLUDES PAINTED WHITE
PARKING LINES. THE FOLLOWING APPLY:
1- GRIND/SHOT BLAST THE FLOOR CREATING A MECHANICAL BOND.
2- PREP THE JOINTS AND INSTALL SIKAFLEX.
3- PLEASE NOTE IF ANY VERTICAL SURFACES ARE INCLUDED THEY WILL VARY IN APPEARANCE
BOTH IN FLAKE AND CLEAR.
4- CLEAN THE FLOOR.
5- APPLY AN MVB EPOXY COATING WITH A BROADCAST OF FLAKE. COLOR IS TO BE A NORMAL
BLEND IF YOU GO INTO HYBRID OPTION AN ADDITIONAL CHARGE PER BOX WILL BE APPLIED.
6- BLOW LEFTOVER FLAKE INTO A CORNER.
7- SCRAPE THE FLAKE 4 DIRECTIONS. BLOW INTO THE CORNER FOR THE SECOND TIME.
8- CLEAN UP THE FLAKE WITH A VACUUM.
9- APPLY A CLEAR COAT OF SHERWIN WILLIAMS MPE AND FULLY BROADCAST FLAKE.
10- SCRAPE THE FLAKE IN ALL FOUR DIRECTIONS AND CLEAN UP THE LOOSE FLAKE.
11- APPLY THE FIRST CLEAR COAT TOP COAT WITH A POLYASPARTIC.
12- APPLY THE SECOND TOP COAT WITH A POLYASPARTIC.
GARAGE WATERLINE SUPPLY UPGRADES.
PARKING BUMPERS
INSTALL PARKING BUMPERS TO PROTECT BUILDING.
CULTURE MARBLE SHOWER
INSTALL CULTURE MARBLE SHOWER ENCLOSURE.
WATERLINE
UPGRADE EXISTING WATERLINE SUPPLY FOR TRUCK FILLING.
ADD HOSEBIB FOR DE-IONIZER.
ADD REINFORCED FAUCET FOR HOSE REEL.
STOREFRONT DOORS - TRULITE ENTRANCES
TRULITE SERIES 300 MEDIUM STILE SWING ENTRANCES.
WIDE STILE SWING DOORS: TRULITE SERIES 500: 5” (127 MM) DOOR STILES
ARCHITECTURAL CLASS II, ETCHED, MEDIUM MATTE, CLEAR ANODIC COATING, 0.4 MIL MINIMUM
THICKNESS.
AD
AREA DRAIN
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
ATC AUTOMATIC TEMPERATURE CONTROL
AW AIR WASHER
B BOILER
BB BASEBOARD
AUTO AUTOMATIC
BDD BACKDRAFT DAMPER
BFP BACKFLOW PREVENTOR
BOU BOTTOM OF UNIT
CC COOLING COIL
CFM CUBIC FEET PER MINUTE
CH CHILLER
CI CAST IRON
CLG CEILING
CO CLEAN OUT
CONN CONNECTION
CP CIRCULATING PUMP
CT COOLING TOWER
CU CONDENSING UNIT
COPPER
CW COLD WATER
DB DRY BULB
DF DRINKING FOUNTAIN
DH DUCT HEATER
DIA DIAMETER
DN DOWN
DWG DRAWING
EA EXHAUST AIR
EAT ENTERING AIR TEMPERATURE
EC ELECTRICAL CONTRACTOR
EVAPORATIVE COOLER
EH ELECTRIC HEATER
EL ELEVATION
ESP EXTERNAL STATIC PRESSURE
EW EMERGENCY EYE WASH
EX EXISTING
F FURNACE
FC FAN COIL UNIT
FD FLOOR DRAIN
FH FIRE HYDRANT
FL FILTER
FLR FLOOR
FOB FLAT ON BOTTOM
FOS FLAT ON SIDE
FOT FLAT ON TOP
FS FLOOR SINK
FU FIXTURE UNIT
GA GAUGE
GC GENERAL CONTRACTOR
GPM GALLONS PER MINUTE
GRD GRADE
HB HOSE BIBB
HDR HEADER
HP HEAT PUMP
HTR HEATER
HU HUMIDIFIER
HVAC HEATING, VENTILATING &
HW HOT WATER
IE INVERT ELEVATION
INSUL INSULATION
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
MAX MAXIMUM
MBH THOUSAND BTU PER HOUR
MC MECHANICAL CONTRACTOR
MECH MECHANICAL
MH MANHOLE
MIN MINIMUM
MU MAKE-UP AIR UNIT
NIC NOT IN CONTRACT
NTS NOT TO SCALE
OA OUTSIDE AIR
ORD OVERFLOW ROOF DRAIN
P PUMP
PRV PRESSURE REDUCING VALVE
P&TV PRESSURE & TEMPERATURE RELIEF VALVE
PSI POUNDS PER SQUARE INCH
PVC POLYVINYL CHLORIDE
QD QUICK DISCONNECT
RA RETURN AIR
RD ROOF DRAIN
RF RELIEF AIR
RI ROUGH-IN
RP RADIANT PANEL
RT ROOFTOP UNIT
RV RELIEF VENT
REQD REQUIRED
SA SUPPLY AIR
SD STORM DRAIN
SF SUPPLY FAN
SP STATIC PRESSURE
SPEC SPECIFICATION
SS STAINLESS STEEL
ST SOUND TRAP
STD STANDARD
TOD TOP OF DUCT
TW THROUGH WALL UNIT
TYP TYPICAL
UH UNIT HEATER
VAV VARIABLE AIR VOLUME
VB VACUUM BREAKER
VTR VENT THROUGH ROOF
W/ WITH
WB WET BULB
WC WATER CLOSET
WH WATER HEATER
AxB BARE SHEET METAL RECTANGULAR DUCT, 'A' AND 'B' ARE INSIDE CLEAR DIMENSIONS.
BARE SHEET METAL ROUND MEDIUM OR LOW
INSULATED ROUND FLEXIBLE DUCT, 5 FEET MAXIMUM.
DIRECTION OF AIRFLOW
SUPPLY DUCT RISER
SUPPLY DUCT DROP
RETURN, EXHAUST, OR OUTSIDE AIR DUCT
RISER
RETURN, EXHAUST, OR OUTSIDE AIR DUCT
DROP
ROUND DUCT DROP
ROUND DUCT RISER
MANUAL VOLUME DAMPERS (SQUARE OR ROUND)
DUCT ACCESS DOOR
INTAKE LOUVER WITH BIRDSCREEN
EXHAUST LOUVER WITH BIRDSCREEN
T THERMOSTAT OR SENSOR
CLEAN OUT
VENT LINE
VENT THROUGH ROOF
140° F. HOT WATER
160° F. HOT WATER
BUTTERFLY VALVE
BALL VALVE
GATE VALVE
CHECK VALVE
PLUG VALVE
PRV
2-WAY AUTO VALVE
3-WAY AUTO VALVE
THERMOMETER
GAUGE
UNION
VTR
140°
160°
120° 120° F. HOT WATER
STRAINER
BALANCING VALVE
RELIEF VALVE
BACKFLOW PREVENTER
PIPE ANCHOR
DIRECTION OF FLOW
EXPANSION JOINT
FLEXIBLE CONNECTION
PIPING TEE DROP TO BELOW
PIPING ELBOW DROP
UNDERGROUND SANITARY SEWER
ABOVE GROUND SANITARY SEWER
UNDERGROUND COLD WATER
UNDERGROUND HOT WATER (120° F.)
ABOVE GROUND COLD WATER
ABOVE GROUND HOT WATER
HOSE BIBB
FLOOR DRAIN
FLOOR SINK
FIRE HYDRANT
GLOBE VALVE
CONNECTION OFF SIDE
CONNECTION OFF BOTTOM
CONNECTION OFF TOP
WATER HAMMER ARRESTER
CAPPED END
SHEET NUMBER/DRAWING TITLE
LEGEND
OXYGEN
VACUUM
ACCESS DOOR
AC ACCESS COVER
AIR ADMITTANCE VALVEAV
BOTTOM OF DUCTBOD
AIR CONDITIONING
AH AIR HANDLING UNIT
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CLR CLEAR
CA COMBUSTION AIR
CD CONDENSATE DRAIN
CONSTRUCTION DOCUMENT
CFH CUBIC FEET PER HOUR
BLD BUILDING
DUCT FURNACE
DESTRATIFICATION FAN
DOWN FLOW
DM DAMPER
DA DILUTION AIR
EQ EQUIPMENT
ENTERING WATER TEMPERATUREEWT
EWC ELECTRIC WATER COOLER
FIRE DAMPER
EXHAUST HOSE
DRAINAGE FIXTURE UNITDFU
FSD FIRE/SMOKE DAMPER
FP FIREPLACE
GI GREASE INTERCEPTOR
GREASE TRAPGT
DOMESTIC COLD WATERDCW
DOMESTIC HOT WATERDHW
CHWR CHILLED WATER RETURN
CHWS CHILLED WATER SUPPLY
CWR CONDENSER WATER RETURN
CWS CONDENSER WATER SUPPLY
CONDENSATE RETURNCR
HE HEAT EXCHANGER
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
L LOUVER
LPG LIQUEFIED PETROLEUM GAS
MANUAL DAMPERMD
NATURAL GASNATGAS
PENT HOUSEPH
RH RELIEF HOOD
RADIANT HEATER
RECIRCULATION PUMP
RELIEF VALVE
SMOKE EXHAUST FANSEF
IH INTAKE HOOD
SANITARY SEWER
GW GREASE WASTE
SELF CONTAINED UNITSC
VAV BOX
UR URINAL
WATER HAMMER ARRESTORWA
CENTER LINECL
OC ON CENTER
ON CENTER EACH WAYOCEW
EF EXHAUST FAN
RAG RETURN AIR GRILLE
TAG TRANSFER AIR GRILLE
FAN POWERED VAV BOXFB
ABBREVIATIONS
1" LINED SHEET METAL RECTANGULAR DUCT, OR
1" FIBERGLASS DUCT, SEE DRAWINGS FOR TYPE,
AxB
'A' IS WIDTH OF DUCT IN VIEW SHOW.
AxB 1 1/2" WRAPPED SHEET METAL RECTANGULAR DUCT, 'A' IS WIDTH OF DUCT IN VIEW SHOW.
A"Ø
PRESSURE DUCT, A"Ø IS DIAMETER.
PRESSURE DUCT, A"Ø IS DIAMETER.
1 1/2" WRAPPED ROUND MEDIUM OR LOWA"Ø
MOTORIZED DAMPER OR FIRE/SMOKE DAMPER
FIRE DAMPER
RECTANGULAR ELBOW WITH TURNING VANES
SLOT DIFFUSER
SQUARE DIFFUSER
ROUND DIFFUSER
24x24 RETURN AIR GRILLE
24x12 RETURN AIR GRILLE
DUCT MOUNTED GRILLE (RECTANGULAR)
BARE SHEET METAL ROUND MEDIUM OR LOW
S SWITCH
H HUMIDITY SENSOR
COMPRESSED AIRA
CD CONDENSATE DRAIN
CONDENSATE RETURNCR
CONDENSER WATER RETURNCWR
CONDENSER WATER SUPPLYCWS
CHILLED WATER RETURNCHWR
CHWS CHILLED WATER SUPPLY
HOT WATER SUPPLY
HOT WATER RETURN
HWS
HWR
NATURAL GASG
OVERFLOW ROOF DRAINOD
HOT WATER RECIRCULATION LINE
ROOF DRAINRD
STEAMS
SOFT COLD WATERSCW
SOFT HOT WATERSHW
V
PIPING ELBOW RISER
SS
SS
SS
SS
DRAWING INDEX
MATERIAL SPECIFICATIONS
RETURN DUCT - SINGLE WALL SHEET METAL WITH 1" LINER.
SUPPLY DUCT - SINGLE WALL SHEET METAL WITH 1" LINER.
MECHANICAL SPECIFICATIONS (UNLESS NOTED OTHERWISE ON PLANS)
LOW PRESSURE ROUND DUCT
PLUMBING SPECIFICATIONS (UNLESS NOTED OTHERWISE ON PLANS)
LOW PRESSURE RECTANGULAR DUCT
SUPPLY DUCT - SINGLE WALL SHEET METAL WITH 1 1/2" INSULATION WRAP (WHERE SHOWN)
RETURN DUCT - SINGLE WALL SHEET METAL WITH 1 1/2" INSULATION WRAP.
EXHAUST DUCT - SINGLE WALL SHEET METAL.
EXHAUST DUCT - SINGLE WALL SHEET METAL.
BELOW GRADE DUCT (ROUND OR RECTANGULAR)
SUPPLY DUCT - SINGLE WALL SHEET METAL WITH PVS COATING.
RETURN DUCT - SINGLE WALL SHEET METAL WITH PVS COATING.
COMBUSTION AIR DUCT - SINGLE WALL SHEET METAL.
FLUE PIPING
SINGLE WALL - ALUMINUM SINGLE WALL (SEE DRAWINGS FOR LOCATIONS).
DOUBLE WALL - ALUMINUM B-VENT PIPE.
DOMESTIC WATER - TYPE 'K' COPPER TUBING WITH LEAD-FREE SOLDER JOINTS.
SANITARY WASTE - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.
BELOW GRADE PIPING
NATURAL GAS -
ROOF DRAINS - SCH40 PVC DWV PIPING WITH SOLVENT GLUED DWV FITTINGS.
ABOVE GRADE PIPING
NATURAL GAS - 2" AND UNDER SCH 40 BLACK PIPE WITH THREADED JOINTS.
NATURAL GAS - 2 1/2" AND OVDER SCH 40 BLACK PIPE WITH WELDED JOINTS.
CONDENSATE DRAINS - (INSIDE) SCH40 PVC WITH SOLVENT CEMENT JOINTS.
CONDENSATE DRAINS - (OUTSIDE) TYPE 'M' CU TUBING WITH SOLDER JOINTS.
GENERAL NOTES
'A' IS WIDTH OF DUCT IN VIEW SHOWN.
'A' AND 'B' ARE INSIDE CLEAR DIMENSIONS.
'A' AND 'B' ARE INSIDE CLEAR DIMENSIONS.
DOMESTIC COLD WATER - 2 1/2" AND OVER TYPE 'L' COPPER TUBING WITH LEAD
FREE SOLDER JOINTS AND 1/2" INSULATION.
DOMESTIC HOT WATER - 2 1/2" AND OVER TYPE 'L' COPPER TUBING WITH LEAD
FREE SOLDER JOINTS AND 1" INSULATION.
DOMESTIC COLD WATER - 2" AND UNDER PEX TUBING WITH METAL
FITTINGS AND STAINLESS STEEL CLAMP BANDS.
DOMESTIC HOT WATER - 2" AND UNDER PEX TUBING WITH METAL
FITTINGS AND STAINLESS STEEL CLAMP BANDS.
HOT WATER RECIRC. - PEX TUBING WITH METAL FITTINGS AND
STAINLESS STEEL CLAMP BANDS.
SANITARY WASTE - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.
SANITARY VENT - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.
ABOVE GRADE PIPING (CONT.)
TH
IS
D
RA
W
IN
G
SH
EE
T
AN
D
AL
L I
NF
OR
MA
TI
ON
H
ER
EO
N
IS
C
OP
YR
IG
HT
ED
A
ND
T
HE
P
RO
PE
RT
Y
OF
JT
B
HV
AC
P
LU
MB
IN
G
EN
GI
NE
ER
IN
G, IN
C.
A
ND
S
HA
LL
N
OT
B
E
US
ED
O
N
AN
Y
OT
HE
R
PR
OJ
EC
T
W
IT
HO
UT
W
RI
TT
EN
P
ER
MI
SS
IO
N
FR
OM
JT
B
HV
AC
P
LU
MB
IN
G
EN
GI
NE
ER
IN
G, IN
C.
MECHANICAL PLANS
ROOF DRAINS - SCH40 PVC DWV PIPE WITH SOLVENT GLUED DWV FITTINGS.
PROVIDE 1" INSULATION ON BOWL AND FIRST 10'-0" OF PIPING.
AIR CONDITIONING
1" FIBERGLASS INSULATION FOR PIPING 1 1/4" AND SMALLER.
DOMESTIC PIPING INSULATION
1 1/2" FIBERGLASS INSULATION FOR PIPING 1 1/2" AND LARGER.
OUTSIDE AIR DUCT - SINGLE WALL SHEET METAL WITH 1" LINER.
OUTSIDE AIR DUCT - SINGLE WALL SHEET METAL WITH 1 1/2" INSULATION WRAP.
A) THESE DRAWINGS WERE PREPARED USING THE 2021 IBC, 2021 IMC,
2021 IPC, 2021 IFGC, AND THE 2021 IECC.
B) ALL INSTALLATIONS SHALL BE PER THE 2021 IBC, 2021 IMC, 2021 IPC,
2021 IFGC, AND THE 2021 IECC.
D) REFER TO ARCHITECTURAL DRAWINGS FOR EXACT LOCATION OF
PLUMBING FIXTURES, LIGHTS, CEILING DIFFUSERS, AND FIRE SPRINKLERS.
C) THESE DRAWINGS ARE TO SHOW THE GENERAL CONCEPT OF THE
SYSTEMS. FIELD VERIFY ALL LOCATIONS AND COORDINATE EXACT
ROUTING WITH ALL TRADES.
E) ALL DUCT SIZES LISTED IN THESE DRAWINGS ARE INSIDE CLEAR
DIMENSIONS UNLESS NOTED OTHERWISE.
F) SLOPE ALL HORIZONTAL SANITARY WASTE AND VENT PIPING A MINIMUM OF
A 1/4" PER FOOT FOR 2 1/2" AND SMALLER, 1/8" PER FOOT FOR 3" TO
6", AND 1/16" FOR 8" AND LARGER.
G) SLOPE ALL HORIZONTAL ROOF DRAINAGE PIPING A MINIMUM OF A 1/8"
PER FOOT UNLESS NOTED OTHERWISE.
H) ALL MATERIALS INSTALLED IN AN AREA ABOVE THE CEILING DESIGNATED
AS A RETURN AIR PLENUM MUST BE NONCOMBUSTIBLE OR SHALL HAVE
A FLAME SPREAD INDEX OF NOT MORE THAN 25 AND A SMOKE-
DEVELOPED INDEX OF NOT MORE THAN 50 WHEN TESTED IN ACCORDANCE
J) ALL UNDERGROUND DUCT SHALL SLOPE TO ALLOW DRAINAGE TO A POINT
PROVIDED WITH ACCESS.
K) PROVIDE CLEANOUTS EVERY 100 FEET ON HORIZONTAL WASTE LINES,
EVERY CHANGE OF DIRECTION GREATER THAN 45°, AT THE BASE OF
BUILDING.
WASTE STACKS, AND NEAR THE POINT THE SEWER ENTERS THE
WITH ASTM E 84.
L) SEISMIC RESTRAINTS ARE REQUIRED PER 2021 IBC. ENGINEERING AND
RESTRAINT SELECTION ARE THE RESPONSIBILITY OF THE MECHANICAL AND
PLUMBING CONTRACTORS.
M) FIRESTOPPING DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE INSTALLING
CONTRACTOR.
N) FIRESTOPPING DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE INSTALLING
CONTRACTOR.
O) AS-BUILT DRAWINGS SHALL BE PROVIDED TO THE OWNER OR OWNERS REPRESENTATIVE
WITHIN 90 DAYS OF CERTIFICATION OF OCCUPANCY.
P) O&M MANUALS FOR THE PROJECT SHALL BE PROVIDED TO THE OWNER OR
OWNERS REPRESENTATIVE WITHIN 90 DAYS OF CERTIFICATION OF
Q) PROVIDE AIR AND WATER BALANCING REPORTS TO BUILDING INSPECTOR
PRIOR TO FINAL INSPECTION.
OCCUPANCY AND INCLUDE THE FOLLOWING ITEMS: EQUIPMENT
SUBMITTALS, MANUFACTURES O&M'S, NAME AND ADDRESS OF AT LEAST
ONE SERVICE AGENCY, HVAC AND SERVICE HOT WATER CONTROLS
MAINTENANCE AND CALIBRATION INFORMATION, AND A NARRATIVE OF
R) PIPE EXPANSION JOINTS IN THE VERTICAL RISERS AND HORIZONTAL RUNS
ARE THE RESPONSIBILITY OF THE INSTALLING CONTRACTOR. FOLLOW
THE INSTALLATION RECOMMENDATIONS FOR EACH PIPE MANUFACTURE.
EXPANSION JOINTS SHOWN IN THE DRAWINGS ARE MINIMUM
REQUIREMENTS AND WILL VARY BASED ON ACTUAL PIPE ROUTING.
IF DESIGN ASSISTANCE IS NEEDED PLEASE CONTACT JTB.
HOW EACH PIECE OF EQUIPMENT IS TO OPERATE INCLUDING SETPOINTS.
M001 TITLE SHEET (LEGEND & ABBREVIATIONS)
M201 MECHANICAL PLAN
P201 PLUMBING PLAN
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt ar ch ite ct ur e
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
TIT
LE
PR
O
JE
C
T
C
LIE
NT
AD
DR
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
TIT
LE
SH
EE
T -
LE
G
EN
D
AB
BR
EV
IA
TIO
NS
TITLE
PAGE
M001
W
AN
SH
IP
FI
RE
ST
AT
IO
N
NO
RT
H
SU
M M
IT
FIR
E
DE
PA
RT
M
EN
T
SO
UT
H
HO
YT
SV
ILL
E
RO
AD
C
O
AL
VI
LL
E, U
TA
H
25.053
JCZ
JTM
7/14/2026
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text #264382
AutoCAD SHX Text
BROWN
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text
JEFF T.
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text G
R
EF
W D
REF.
KEYED NOTES
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt ar ch ite ct ur e
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
TIT
LE
PR
O
JE
C
T
C
LIE
NT
AD
DR
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
M
EC
HA
NI
C
AL
P
LA
N
MECHANICAL
PLAN
M201
25.053
JCZ
JTM
7/14/2026
W
AN
SH
IP
FI
RE
ST
AT
IO
N
NO
RT
H
SU
M M
IT
FIR
E
DE
PA
RT
M
EN
T
SO
UT
H
HO
YT
SV
ILL
E
RO
AD
C
O
AL
VI
LL
E, U
TA
H
SCALE:
MECHANICAL PLAN
1/4" = 1'-0"
NORTH
0 1' 2' 4' 8'
HP
PIPE CONDENSATE TO LAV TAILPIECE
DS
DS
DS
LIQUID SUCTION DIFF MAX
HP
ELECTRICAL
MULTI-ZONE OUTDOOR HEAT PUMP UNIT SCHEDULE
HEAT PUMP UNIT LOCATION
AREA SERVED
HP
TAG TONS/
NOMINAL
POWER
V/PH/HZ
BTU/H
DX COOLING CAP.
HEAT PUMP UNIT MANUFACTURER
REFRIGERANT
inches
CONNECTIONS
NECT/
STARTER
DISCON-MCA/
FUSE MODEL NUMBER
OPER.
WEIGHT
lbs.EFF. AMBIENT 94/59°F
BTU/H
AMBIENT
-5°F
DX HEAT CAP.
TYPE feet
MAX PIPE
ON GRADE
SLEEPING - R-410A 1/4 1/2 150
DAIKIN
3MXL24WMVJU9STD
24,000
BY EC
N/A 49 13220
17.5 208/1/6024,000
DUCTLESS SPLIT INDOOR UNIT SCHEDULE
DUCTLESS SPLIT INDOOR UNIT MANUFACTURER
MODEL NUMBER
CFM
at
5,300'
EXT.
SP
inches
ELECTRICAL
EAT LATSENSIBLE TOTAL
BTUH
OPER.
WEIGHT
lbs.
DESIGN COND
°F DB/WB
COOLING AIR
WALL
DUCTLESS SPLIT INDOOR UNIT LOCATION
AREA SERVEDTAG POWER
V/PH/HZ NECT/
STARTER
DISCON-MCA/
FUSE
-300
-7,0007,000SLEEPING 1 208/1/60 - N/A
- HP-1
CTXS07WVJU9
DAIKIN
HEATING
EAT LAT
DESIGN COND
°F DB/WB
TOTAL
8,000
BTUH
1 PROVIDE CONDENSATE PUMP AND WALL MOUNTED THERMOSTAT.
DS
WALL
SLEEPING 2
DS
WALL
SLEEPING 3
DS
-300
-7,0007,000 208/1/60 - N/A
- HP-1
CTXS07WVJU9
DAIKIN
-8,000
-300
-7,0007,000 208/1/60 - N/A
- HP-1
CTXS07WVJU9
DAIKIN
-8,000
SCALE:
DRYER WALL VENT DETAILA NTS
FASTENER THRU
NYLON SLEEVE
SEALANT AT PERMIETER
OF PENETRATION
DRYER VENT
SET FLANGE IN SEALANT
FASTENER SET IN SEALANT
4"
AutoCAD SHX Text
THROUGHOUT THE
AutoCAD SHX Text
NO WORK IN THIS AREA
AutoCAD SHX Text T
AutoCAD SHX Text
SLEEPING 1
AutoCAD SHX Text
SLEEPING 2
AutoCAD SHX Text
SLEEPING 3
AutoCAD SHX Text
OFFICE/SLEEPING 4
AutoCAD SHX Text
MECHANICAL
AutoCAD SHX Text
STORAGE
AutoCAD SHX Text
KITCHEN
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
RESTROOM
AutoCAD SHX Text
EQUIPMENT BAY
AutoCAD SHX Text
GROUP ROOM
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text
SHOWER
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text G
AutoCAD SHX Text I
AutoCAD SHX Text #264382
AutoCAD SHX Text
BROWN
AutoCAD SHX Text H
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text E
AutoCAD SHX Text T
AutoCAD SHX Text A
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text N
AutoCAD SHX Text E
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text E
AutoCAD SHX Text
JEFF T.
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text P
AutoCAD SHX Text R
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text I
AutoCAD SHX Text O
AutoCAD SHX Text N
AutoCAD SHX Text A
AutoCAD SHX Text L
AutoCAD SHX Text E
AutoCAD SHX Text N
WD
REF.REF.
WD
REF.REF.
KEYED NOTES
PROJECT #:
DRAWN BY:
CHECKED BY:
ISSUED:
alt ar ch ite ct ur e
1445 w. 8660 s.
west jordan, utah 84088 www.altarchitecture-ut.com
TIT
LE
PR
O
JE
C
T
C
LIE
NT
AD
DR
ES
S
NO. DATE DESCRIPTION
SHEET
REVISIONS
PL
UM
BIN
G
P
LA
N
PLUMBING
PLAN
P201
25.053
JCZ
JTM
8/10/2026
W
AN
SH
IP
FI
RE
ST
AT
IO
N
NO
RT
H
SU
M M
IT
FIR
E
DE
PA
RT
M
EN
T
SO
UT
H
HO
YT
SV
ILL
E
RO
AD
C
O
AL
VI
LL
E, U
TA
H
SCALE:
PLUMBING PLAN
1/4" = 1'-0"
NORTH
0 1' 2' 4' 8'
PIPE CONDENSATE TO LAV TAILPIECE
DS
DS
DS
2 CONNECT TO EXISTING DCW. FIELD VERIFY LOACTION.
3 CONNECT TO EXISTING DHW. FIELD VERIFY LOACTION.
4 CONNECT TO EXISTING SS. FIELD VERIFY LOACTION.
5 CONNECT TO EXISTING VENT. FIELD VERIFY LOACTION.
3" 1/2
1/2
1-1/2"
WB
WB
WASHER BOX
- 1/2" 1/2" 2" 2" 2" WHITE
SIOUX CHIEF
696-G2313XF- WATER HAMMER ARRESTOR
1/4 TURN VALVEPEX CRIMP CONNECTION
PLUMBING SCHEDULE
FIXTURE MANUFACTURER
MODEL NUMBER
FIXTURE ROUGH-IN SIZES
COLD HOT VENTTRAP
inches
WASTE
FINISH
ACCESSORIES AND COMMENTSTAG
FIXTURE TYPE
MOUNTING LOCATION DOMESTIC WATER WASTE & VENT COLOR
SCALE:
WASHING MACHINE BOX DETAILA NTS
1/2" HW
2" STANDPIPE
HOSE BIBS WITH
3" WASTE
2" VENT
WASHING
MACHINE BOX
1/2" CW
WATER HAMMER
VACUUM BREAKER
ARRESTOR (TYP)
AND P-TRAP
SHOWER
2"1/2" 1/2" 2"2" CHROME
SH
1 MOEN FAUCET (T8375)
-PEERLESS VALVE (PTR188700-UN)
SIOUX CHIEF FLOOR DRAIN(832-25PNRE)
WATER CLOSET
FLOOR MOUNT-TANK -1/2" WHITE2"- 4"
KOHLERWC
1 K-3979BEMIS WHITE SEAT (1955C) LEFT CHROME TRIP LEVER
PROFLO CHROME ESCUTCHEONBRASS CRAFT 1/4 TURN ANGLE STOP WITH SS SUPPLY HOSE
COUNTER MOUNT
LAVATORY-ADA
1-1/4"1/2" 1/2" 2"2" WHITE MOEN FAUCET (8800 CHROME)
KOHLERLAV
INSULATED P-TRAP COVER
PROFLO 1 1/4" SS GRID STRAINER AND P-TRAP
SIOUX CHIEF OXBOX (696-G2011XF), WATTS LFUSG-CS MIXING VALVE
K-2196-4
WATER CLOSET
FLOOR MOUNT-TANK -1/2" WHITE2"- 4"
KOHLERWC
2 K-3979BEMIS WHITE SEAT (1955C) RIGHT CHROME TRIP LEVER
PROFLO CHROME ESCUTCHEONBRASS CRAFT 1/4 TURN ANGLE STOP WITH SS SUPPLY HOSE
SCALE:
PLUMBING - DWVA 1/4" = 1'-0"
WB
SCALE:
PLUMBING - DWVB 1/4" = 1'-0"
1/2
1/2
WB
WC
WC
LAV
LAV
SH
SH
6 RELOCATE TOILET FLANGE FOR NEW LAYOUT
RELOCATE DCW TO WC FOR NEW LAYOUT
7 7
8 REMOVE DF AND CAP PIPES IN WALL
A&B P201
HB
HOSE BIBB / JS FAUCET
1/2" 1/2"
FIAT
-FIAT HOSE AND BRACKET (832-AA)
FIAT FAUCET (830-AA)
RP
HOT WATER RECIR. PUMP
- SUPPLY COMPANION FLANGES
1" THREADED UNION CONNECTION
006E3-- -- 3/4" -
ELECTRICAL – 115V / 1Ø / 60 (1/40 HP, 0.54 AMPS) - HARDWIRED
1 GPM @ 5 FEET OF HEAD, **AUTO SHUT OFF AND TIMER
TACO
**CONTROLS FOR CIRCULATING HOT WATER SYSTEM PUMPS SHALL AUTOMATICALLY TURN…
This is the start of the file's text. The full file is on GovTribe.