Tyfo S Epoxy 030622.pdf

PDF 67 KB Posted

Attached to
MIA ATCT Precast Panel Repair Federal contract opportunity
Solicitation number
697DCK-22-R-00172
Issued by
Department of Transportation Federal Aviation Administration Southwestern Region

About this file

This solicitation requests proposals for precast panel repairs to the Miami International Airport Air Traffic Control Tower located in Miami, Florida. The Federal Aviation Administration requires repair services for the precast panels and has provided a Solicitation/Request for Proposal with response due date of May 2, 2022. Offerors must be registered in the System for Award Management to be considered and eligible for award. The site visit information is detailed in Section L.3 of the solicitation.

View the file

Other files for this federal contract opportunity

Other files attached to MIA ATCT Precast Panel Repair, newest first.
File Type Posted
20220628_073352.jpg JPG image
20220628_073400.jpg JPG image
20220628_073123.jpg JPG image
Questions and Response Set 4.docx DOCX document
Q and A Set 3.pdf PDF
697DCK-22-R-00172 Amend 04.pdf PDF
so-d-102506-a15.pdf PDF
so-d-102506-a23.pdf PDF
so-d-102506-a16.pdf PDF
so-d-102506-a17.pdf PDF
SurCoPrimer Data Sheets.pdf PDF
Q and A Alternative Product MIA Precast.pdf PDF
Tyfo SCH-41S 030622.pdf PDF
697DCK-22-R-00172 Amd 3.pdf PDF
Q and A Set 1 MIA Precast Panel Repair.docx DOCX document
697DCK-22-R-00172 0002.pdf PDF
MIA ATCT Precast Panel Repair Drawings REVISED 05112022.pdf PDF
MIA ATCT Precast Panel Repair Specifications REVISED_05112022.pdf PDF
697DCK-22-R-00172 00001.pdf PDF
Wage Rate FL20220215 4.01.22.pdf PDF
L4. 7460-1.pdf PDF
697DCK-22-R-00172.pdf PDF
MIA ATCT Precast Panel Repair Operational Risk Management Plan REVISED.pdf PDF
MIA ATCT Precast Panel Repair Drawings REVISED.pdf PDF
MIA ATCT Precast Panel Repair Specifications 04072022.pdf PDF
COVID-19 Contractual Requirement Rev 1 8-26-20.pdf PDF
L1. BidBond.pdf PDF
L2. Past Performance Questionnaire.pdf PDF
L3. Price Proposal.xlsx XLSX spreadsheet
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

TYFO® S

Saturant Epoxy

DESCRIPTION

The Tyfo® S Epoxy is a two-component epoxy matrix material for bonding applications. The Tyfo® S Epoxy combined with the Tyfo® fabrics make up the Tyfo® Systems which are NSF/ ANSI Standard 61-G certified for drinking water systems. It is a high elongation material which gives optimum properties as a matrix for the Tyfo® system. It provides a long working time for application, with no offensive odor.

USE

The Tyfo® S Epoxy matrix material is combined with the Tyfo® fabrics to provide an ambient-cure wet-layup composite system for strengthening structural members. Tyfo® S Epoxy may be thickened with fumed silica (such as Cab-O-Sil TS-720) to be used as a primer, tack coat or finish depending on project requirements.

ADVANTAGES

• ICC-ES ESR-2103 listed product

• IAPMO UES ER-595 listed product

• Tyfo® Systems are NSF/ANSI Standard 61-G certified

• Good high and low temperature properties

• 100% solids, solvent-free

• Long working time

• High elongation

• Ambient cure

PACKAGING

Pre-measured 5-gallon units with a combined material volume of 4 gallons or in 55-gallon drums.

EPOXY MIX RATIO

100A : 34.5B by weight 100A : 42.0B by volume

CONSUMPTION RATE

Fabric-to-epoxy ratio by weight:

For Tyfo® SCH Fabrics: 1 : 1 For Tyfo® SEH Fabrics: 1 : 0.8

SHELF LIFE

Epoxy - two years in original, unopened and properly stored containers.

Fabric - 10 years in proper storage conditions.

STORAGE CONDITIONS

Store epoxy at 60°F to 100°F (15°C to 38°C).

Resin is susceptible to crystallization at temperatures below 50°F. If crystallized, epoxy must be reheated until clear. Store fabric rolls flat, not on ends, and at temperatures below 100°F (38°C). Avoid moisture and water contamination.

Epoxy Material Properties

Material properties are based on standard laboratory conditions (23oC, 50 percent relative humidity.)

Property Typical Test Value

Net Weight Component A Component B Mixed

27.4 lbs. (2.8 gal)

9.60 lbs. (1.2 gal)

37.0 lbs. (4.0 gal)

Color Component A Component B Mixed

Clear to amber Clear to yellow Clear to amber

Viscosity Component A Component B Mixed

11,000-13,000 cps 11 cps 600-700 cps

Density (D792) Pounds/Gallon

Component A Component B Mixed

9.7 (1.16 kg/L)

7.9 (0.95 kg/L)

9.2 (1.11 kg/L)

Pot Life (Working Time) Mixed 3 to 4 hours

Gel Time (Time to Gelation) Mixed 10 hours

1 Testing temperature: 73oF (23oC).

2 Adhesion strength dependent on surface preparation and substrate thickness. Concrete adhesion strength is dependent on the concrete strength and is based on a minimum CSP-2 profile. Steel adhesion strength is based on SSPC-SP10 and SSPC-SP11 surface preparation methods. Cure schedule: 7 days at 73°F (23°C).

Epoxy Material Properties

Cure schedule: 72 hour post-cure at 140oF (60oC)1

Property ASTM Method Typical Test Values

Glass Transition Temperature, Tg

D4065 E1356

180oF (82 C)

Tensile Strength

D638 Type 1

10,500 psi (72.4 MPa)

Tensile Modulus 461,000 psi (3.18 GPa)

Elongation 5.0%

Compressive Strength D695

12,500 psi (86.2 MPa)

Compressive Modulus 465,000 psi (3.2 GPa)

Flexural Strength D790

17,900 psi (123.4 MPa)

Flexural Modulus 452,000 psi (3.12 GPa)

Shore D Hardness D2240 87±3

Water Absorption (24 hours) Water Absorption (13 weeks) D570 0.33%

1.98%

Adhesion Strength2

Concrete (ASTM D7522) Steel Epoxy

D4541 >400 psi (concrete failure typ.)

>1200 psi >1200 psi

HOW TO USE THE TYFO® S SATURANT EPOXY

INSTALLATION

The Tyfo® system is to be installed by FyfeFRP LLC trained and certified applicators in accordance with the FyfeFRP LLC quality control manual, project specifications, and design requirements.

SURFACE PREPARATION

The required surface preparation is dependent on the type of element being strengthened. In general, the surface must be clean, dry and free of protrusions or cavities to prevent voids behind the Tyfo® system. Column surfaces that will receive continuous wraps typically only require a clean, sound substrate. Discontinuous wrapping surfaces (walls, beams, slabs, etc.) require a minimum CSP-2 profile to prepare for bonding, achieved by light sandblast, grinding or other approved methods per ICRI 310.2R. Tyfo® Composite Anchors may be incorporated in the designs.

FyfeFRP LLC engineering staff will provide the proper specifications and details based on project requirements.

MIXING TYFO® S EPOXY

For pre-measured units in 5-gallon containers, pour the contents of component B into the component A container. Mix thoroughly with a low speed mixer at 400 to 600 RPM until uniformly blended. Ensure epoxy is transferred between the A and B buckets. For 55-gallon drums, mix component A and component B per the appropriate weight or volumetric mix ratio. Resin may be heated to achieve desired viscosity (i.e. radiant heating, drum heaters, water bath). Mixed Tyfo® S Epoxy may be thickened by adding up to 7 percent by weight of fumed silica (such as Cab-o-sil TS-720) or approved filler such as HDPE fibers. DO NOT THIN. Solvents will prevent proper cure.

THICKENED TYFO® S EPOXY

Use Cab-o-sil TS-720 by Cabot Corp. or similar. For horizontal and vertical surfaces, use up to 2.0 lbs. fumed silica per kit or 5.4 percent by weight. For overhead surfaces use up to 2.5 lbs. per kit or 6.7 percent by weight.

Site conditions may affect the amount of fumed silica required to achieve desired thickness. Do not exceed 7 percent by weight.

APPLICATION

Tyfo® S Epoxy is applied to the Tyfo® fabric using a saturator machine or by approved manual saturation methods (trowel, roller, or similar). Hand saturation is allowable, provided the epoxy is applied uniformly and meets the required fiber-to-epoxy ratio. Tyfo® S Epoxy is applied as a prime coat by brush or roller. Please refer to FyfeFRP LLC’s NSF Listing for the NSF 61-G listed application method (www.NSF.org).

LIMITATIONS

Recommended substrate temperature range is 50°F to 100°F (10°C to 38°C). All coating applications to be performed at a minimum of 5.4°F above the dew point. Maintain conditions for the first 48 hours of cure.

Temperatures below 50°F will significantly increase the viscosity of the mixed product. Higher viscosity will reduce fabric penetration, introduce additional air into the system, and extend the cure times beyond 48 hours. DO NOT THIN. Solvents will prevent proper cure.

CAUTION!

Statement of Responsibility: The technical information and application advice in this publication is based on the present state of our best scientific and practical knowledge. As the nature of the information herein is general, no assumption can be made as to the product’s suitability for a particular use or application, and no warranty as to its accuracy, reliability or completeness, either expressed or implied, is given other than those required by State legislation. The owner, his representative or the contractor is responsible for checking the suitability of products for their intended use. Field service, where provided, does not constitute supervisory responsibility. Suggestions made by the FyfeFRP LLC, either verbally or in writing, may be followed, modified or rejected by the owner, engineer or contractor since they, and not the FyfeFRP LLC, are responsible for carrying out procedure appropriate to a specific application.

Consult safety data sheet (SDS) for more information.

For industrial use only.

CLEANUP

Collect with absorbent material. Dispose in accordance with local disposal regulations. Uncured material can be removed with approved solvent. Cured materials must be mechanically removed.

HAZARDS

Consult the Safety Data Sheets (SDS) for associated hazards. SDS will be supplied upon request.

V: 03.06.2022© 2022 FyfeFRP, LLC. All rights reserved. Fyfe® and Tyfo® are the registered trademarks of FyfeFRP, LLC.

FyfeCo.com | FyfeInfo@cs-nri.com | +1.855.708.3617