Finding Detail Report - 229.2.pdf

PDF 275 KB Posted

Attached to
TRAINING SHIP FREEDOM STAR (TSFS) FY23 REGULATORY DRY DOCKING
Solicitation number
6933A222Q000025
Issued by

About this file

This document contains a finding detail report from an ABS Survey Manager review of the training ship Freedom Star, as well as information about an upcoming federal contract opportunity for the regulatory dry docking of that vessel.

The finding detail report outlines substantial corrosion found on the longitudinal bulkhead vertical angles and flanges in the number three port side ballast tank during an intermediate hull survey. It documents gauging and coating of the affected areas at subsequent annual surveys, with the most recent rectification occurring in April 2022. The areas must continue to be gauged at annual surveys until renewed. The related federal contract opportunity is a solicitation by the Maritime Administration to provide industrial support for the regulatory dry docking of the training ship Freedom Star in accordance with the statement of work, with response due dates to be specified in the forthcoming solicitation.

View the file

Other files

File Type Posted
TSFS 2020 Anchor Chain Gauging.pdf PDF
Bow Thruster Maintenance - Final Service Report.pdf PDF
TSFS Tankages 2022.pdf PDF
Answers to questions submitted by various vendors.pdf PDF
Bow Thruster 1.pdf PDF
Bow Thruster Maintenance Report.pdf PDF
Bow Thruster 2.pdf PDF
Freedom Star 6-3-2020 Soundings.pdf PDF
Amdmt 0004 TSFS 6933A222Q000025.pdf PDF
2020 Rudder and Skeg Inspection and Pintle Clearances.pdf PDF
TSFS 6933A222Q000025 Amndmt 0003.pdf PDF
4 Questions and Answers TSFS 2023 DD.pdf PDF
2020 Item 207 Ultrasonic Thickness Gauging - Final.pdf PDF
Rudder Anodes Pic 2.pdf PDF
Rudder Anodes Pic.pdf PDF
Windward 22 Gauging TS FREEDOM STAR.pdf PDF
2021 Corrosion Guaging Report.pdf PDF
Finding Detail Report - 230.2.pdf PDF
Freedom Star VALVE SURVEY FORM for Marad 9-8-22qt.xlsx XLSX spreadsheet
New WO Valves Quote.pdf PDF
MVFS Mooring Analysis.pdf PDF
2020 xx Zinc Anodes Locations.pdf PDF
1547 4420 Rev 3 Bow Thruster Arr.pdf PDF
Switchboard DWG 19159-1 19159-2 19159 3 19159 4 DWG 19157 1 19157 2 19157 3 19157 4.pdf PDF
TSFS 6933A222Q000025 Amdmt 00002.pdf PDF
Hurricane Preparedness and Heavy Weather Mooring Plan.pdf PDF
Item 201 DRY DOCK SHIP.pdf PDF
Stern Thruster 2768WG D 32HJP SECTIONAL ARRANGEMENET.pdf PDF
1547 4419 Rev 1 Stern Thruster Compt Machy Arr.pdf PDF
1427 802 Rev TV FREEDOM STAR General Arrangements and Profile.pdf PDF
KINGS POINTER Tank Tables 15 Oct 13.pdf PDF
3 Questions and Answers TSFS 2023 DD.pdf PDF
1780 2550 Stern Thruster AD.pdf PDF
2 Questions and Answers TSFS 2023 DD.pdf PDF
Freedom Star NEW ITEM 205 SEA VALVES.pdf PDF
Tank Plan ST Locations.pdf PDF
1 Questions and Answers TSFS 2023 DD.pdf PDF
1547 2515 Rev 6 Transverse Bhds.pdf PDF
1547 2510 Rev 7 Long l Struct Sections.pdf PDF
Amdmt 0001 TSFS 6933A222Q000025.pdf PDF
TSFS FY22 DD combined synopsis solicitation.pdf PDF
Siemens-Allis Switchgear Parts Ordering Guide Type LA-600A.pdf PDF
August 2022 RRF Coatings Guidelines.xls XLS spreadsheet
1547-4705_Rudder Details.pdf PDF
Shell Expansion Drawing.pdf PDF
TSFS 2023 DD SOW Rev3.docx DOCX document
2018 Bow Thruster Maintenance - Final Service Report.pdf PDF
1547-1420 Docking Plan.pdf PDF
MA-57_Drydock_Report.pdf PDF
Gen Breakers Exterior.pdf PDF
Show 40 more

Latest 50 of 71 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

18 Oct 2022

Finding Detail Report

FREEDOM STAR

Finding Number: 229.2

Report generated on: 18-Oct-2022

THIS REPORT HAS BEEN PRODUCED FROM FREEDOM AND IS SUBJECT TO ERRORS AND CHANGES THAT MAY OCCUR OUTSIDE THE FREEDOM APPLICATION.

ABS ASSUMES NO RESPONSIBILITY FOR ERRORS OR ACTIONS TAKEN BASED ON THE INFORMATION HEREIN. ABS'S ENTIRE RESPONSIBILITY AND LIABILITY IS

GOVERNED BY THE LICENSE AGREEMENT FOR ABS SURVEY MANAGER

Finding Detail Report Finding 229.2

Report generated on: 18 Oct 2022

229.2 Outstanding

Service Type: Class Certification Associated Task: Intermediate Hull Survey 9 Status: Open Criticality: Additional Requirement Opened In Report: 4311189 Last Visit Date: 21-Jul-2020 Port: Philadelphia Port Asset Name: Arrangement/Compartment/Tank/Ballast Tank 03 POB Failure Alert: No Length(mm): Due By Task: Width (mm):

Failure Type: Wastage Failure Descriptor: Substantial Corrosion Recommended Action:

Depth (mm):

Description:

The following area(s) were found with substantial corrosion within the #3 Port

SWB

tank:

- Longitudinal Bulkhead vertical angles on the flanges

229.2 Recommendation

Criticality: Additional Requirement Due By Task: Annual Hull Survey 5 Due Date: 08-Feb-2023 Report Number: 5223384 Port: Philadelphia Port Last Visit Date: 06-Apr-2022 Failure Type: Wastage Failure Descriptor: Substantial Corrosion Recommended Action: Gauge

Description:

The areas of substantial corrosion were visually examined and gauged at this time. These areas are to be gauged at each subsequent annual survey or until renewed.

Time Line

229.0 Rectification

Report Number: 4720139 Port: Philadelphia Port Rectification Date: 07-Apr-2021 Failure Type: Wastage Failure Descriptor: Substantial Corrosion Rectification Action: Re-inspected

Description:

The suspect areas of substantial were gauged at this time and coating visually examined and found intact to the satisfaction of the attending Surveyor.

229.0 Recommendation

Criticality: Additional Requirement Due By Task: Annual Hull Survey 3 Due Date: 08-May-2021 Report Number: 4311189 Port: Philadelphia Port Last Visit Date: 21-Jul-2020 Failure Type: Wastage Failure Descriptor: Substantial Corrosion Recommended Action: Gauge

Description:

The areas of substantial corrosion were coated at this time. These areas are to be gauged at each subsequent annual survey or until renewed.

229.1 Rectification

Report Number: 5223384 Port: Philadelphia Port Rectification Date: 06-Apr-2022 Failure Type: Wastage Failure Descriptor: Substantial Corrosion Rectification Action: Gauged

Description:

The suspect areas of substantial were gauged at this time and coating visually examined and found intact to the satisfaction of the attending Surveyor.

229.1 Recommendation

Criticality: Additional Requirement Due By Task: Annual Hull Survey 4 Due Date: 08-May-2022 Report Number: 4720139 Port: Philadelphia Port Last Visit Date: 07-Apr-2021 Failure Type: Wastage Failure Descriptor: Substantial Corrosion Recommended Action: Re-inspect

Description:

The areas of substantial corrosion were visually examined and gauged at this time. These areas are to be gauged at each subsequent annual survey or until renewed.

File details come from the government source that posted it. Updated .