5 - Control Building - (A - FA - M - P - E - SF) Series.pdf
PDF 14 MB Posted
- Solicitation number
- W912DS22B0022
About this file
This document provides details of a federal contract solicitation for construction services. The U.S. Army Corps of Engineers, New York District is seeking proposals for Segment C2 and H Contract 2 of the Green Brook Flood Risk Management Project located in Middlesex Borough, New Jersey. The scope of work involves constructing approximately 1,700 feet of earthen levee, 100 feet of floodwall, and associated closure gates along Segment C2 of Bound Brook, as well as 3,600 feet of earthen levee tying into a railroad embankment, 576 feet of floodwall, and an additional closure gate along Segment H of Bound Brook. The projected value of the contract is between $25-100 million. The period of performance is 730 calendar days from notice to proceed. Proposals must be submitted electronically by the deadline specified in the solicitation. The point of contact for any questions is the named Contract Specialist with the U.S. Army Corps of Engineers, New York District.
View the file
Other files
Show all 37
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ARCHITECTURAL DIMENSIONING
UNLESS OTHERWISE NOTED ALL
EXTERIOR DIMENSION STRINGS ARE
TO THE FINISH FACE OF WALL
(FROM OPENINGS IN WALL)
UNLESS OTHERWISE NOTED LOCATE
THE EDGE OF DOOR JAMBS 8" OFF OF
THE FINISHED FACE OF ADJACENT
CMU PARTITION
UNLESS OTHERWISE NOTED ALL
DIMENSION STRINGS ARE TO THE
FINISH FACE OF WALL OR PARTITION
4. DO NOT SCALE DRAWINGS - FOLLOW WRITTEN DIMENSIONS ONLY.
5. TYPICALLY, DIMENSIONS ARE TO FACES OF FINISHED WALL OR
PARTITION SURFACE OR TO EDGE OF OPENINGS.
6. COORDINATE DIMENSIONS INDICATED IN THESE DRAWINGS WITH
FABRICATION OF ALL SYSTEMS AND ASSEMBLIES. COORDINATE
DIMENSIONS INDICATED WITH ACTUAL FIELD CONDITIONS. REPORT ANY
INCONSISTENCIES TO THE ARCHITECT PRIOR TO PROCEEDING WITH
WORK.
7. "EQ" AS USED IN THESE DOCUMENTS IS THE ABBREVIATION FOR "EQUAL" -
MEANING THAT THE DIMENSIONS ON A STRING ARE INTENDED TO BE OF
EQUAL LENGTH.
8. " +/- " OR "VERIFY" AS USED IN THESE DOCUMENTS MEANS THAT FOR
EXISTING CONDITIONS THE DIMENSIONS SHALL BE VERIFIED IN THE FIELD
BY THE CONTRACTOR AND FOR NEW CONDITIONS THE ACTUAL
DIMENSION AS CONSTRUCTED MAY BE ADJUSTED SLIGHTLY TO
ACCOMMODATE OTHER FACTORS.
9. "MIN" AS USED IN THESE DOCUMENTS IS THE ABBREVIATION FOR
"MINIMUM" - MEANING THAT THE CONDITION IS SLIGHTLY ADJUSTABLE BUT
MAY NOT VARY TO A DIMENSION OR QUALITY LESSER THAN THAT
INDICATED.
10. "MAX" AS USED IN THESE DOCUMENTS IS THE ABBREVIATION FOR
"MAXIMUM" - MEANING THAT THE CONDITION IS SLIGHTLY ADJUSTABLE
BUT MAY NOT VARY TO A DIMENSION OR QUALITY GREATER THAN THAT
INDICATED.
11. "CLEAR" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE
DIMENSION IS NOT ADJUSTABLE WITHOUT THE WRITTEN APPROVAL OF
THE ARCHITECT OR ENGINEER. CLEAR DIMENSIONS ARE TYPICALLY TO
FINISH FACE.
12. "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY
LOCATE THE FINISHED FACES TO BE IN THE SAME PLANE.
13. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE
CONDITION OR DIMENSION IS THE SAME OR REPRESENTATIVE FOR
SIMILAR CONDITIONS THROUGHOUT.
14. "SIMILAR" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE
CONDITION OR DIMENSION IS THE SAME OR REPRESENTATIVE FOR
SIMILAR CONDITIONS THROUGHOUT.
1.
2.
3.
1. GRAPHIC DESIGNATIONS OF MASONRY PARTITIONS AND WALLS ARE
DIAGRAMMATIC ONLY AND DO NOT INDICATE OR IMPLY THE ACTUAL
NUMBER OF COURSES REQUIRED TO ACHIEVE PARTITION HEIGHTS.
2. DAM FLASHING AT JAMBS TO PREVENT WATER FROM ENTERING THE
WALL AND TO ENSURE THAT COLLECTED WATER IS DIRECTED TOWARDS
THE WEEPS.
MASONRY GENERAL NOTES
1. ANY OF THE SYMBOLS / MATERIAL REFERENCED ON THIS DRAWING MAY
OR MAY NOT OCCUR AS A PART OF THIS PROJECT AND ARE PROVIDED
FOR REFERENCE ONLY.
2. REFER TO STRUCTURAL FOR SHEAR WALLS, FOOTING AND
FOUNDATION WALL INFORMATION.
3. ALL PARTITION / WALL MOUNTED EQUIPMENT NOT INDICATED ON THE
DRAWINGS SHALL BE COORDINATED WITH THE ARCHITECT PRIOR TO
INSTALLATION.
4. NOTES AND DETAILS ON DRAWINGS SHALL TAKE PRECEDENCE OVER
GENERAL NOTES AND TYPICAL DETAILS. WHERE NO SPECIFIC DETAILS
ARE INDICATED, CONSTRUCTION SHALL CONFORM TO SIMILAR WORK
ON THE PROJECT.
5. EQUIPMENT LOCATIONS INDICATED ON ARCHITECTURAL DRAWINGS
ARE FOR REFERENCE ONLY. EQUIPMENT LOCATIONS SHALL BE
COORDINATED WITH UTILITIES INDICATED ON CIVIL, MECHANICAL,
PLUMBING, AND ELECTRICAL DRAWINGS.
6. WHILE CARE HAS BEEN TAKEN TO COORDINATE MECHANICAL AND
ELECTRICAL PENETRATIONS WITH ARCHITECTURAL WORK,
CONTRACTOR IS RESPONSIBLE FOR FRAMING MODIFICATIONS AND
PATCHING REQUIRED WHETHER SPECIFICALLY SHOWN OR NOT.
7. IN EXTERIOR WALLS WITH THERMAL INSULATION, PROVIDE
CONTINUOUS AIR BARRIER WHETHER NOTED ON DETAILS OR NOT.
8. THE CONTRACTOR SHALL REFER TO ARCHITECTURAL REFLECTED
CEILING PLANS FOR THE GENERAL INTENDED LAYOUTS OF MECHANICAL
AND ELECTRICAL SYSTEMS.
9. INSTALLED FLOOR FINISHES SHALL BE PROTECTED FROM DIRECT
CONTACT BY MEANS OF COVERING FOR DURATION OF CONSTRUCTION.
10. "GFGI" AS USED IN THESE DOCUMENTS IS THE ABBREVIATION FOR
"GOVERNMENT FURNISHED, GOVERNMENT INSTALLED".
ARCHITECTURAL GENERAL NOTES
AIR BARRIERS
1. THE ENTIRE BUILDING IS CONSIDERED ONE ZONE.
2. ALL AIR BARRIER SYSTEMS ARE FLASHED AND SEALED AIR TIGHT AT ALL
LOUVERS, DOORS, AND AT ALL WALL AND ROOF TRANSITIONS AND
PENETRATIONS TO MAINTAIN A CONTINUOUS PLANE OF AIR TIGHTNESS
THROUGHOUT THE BUILDING ENVELOPE.
3. LAP ALL AIR BARRIER SYSTEMS 4" MINIMUM AND SEAL AIR TIGHT ONTO
THE ADJACENT SURFACE TO MAINTAIN A CONTINUOUS PLANE OF AIR
TIGHTNESS THROUGHOUT THE BUILDING ENVELOPE.
GENERAL SYMBOLS
KEYED NOTE
DOOR TAG
PARTITION TYPE TAG
(FIRST DIGIT INDICATES HOURLY FIRE RATING)
ELEVATION TARGET
NORTH ARROW
REVISION CLOUD
REVISION DESIGNATION TAG
LOUVER TYPE TAG
BREAK LINE
INDICATES PLAN NORTH
INTERIOR ELEVATION DESIGNATION
EXTERIOR ELEVATION DESIGNATION
SECTION / DETAIL DESIGNATION
DETAIL DESIGNATION
DRAWING /DETAIL LOCATION DESIGNATION
DRAWING/DETAIL TITLE
SHEET NUMBER DESIGNATION WHERE
FIRST REFERENCED
DRAWING/DETAIL LIMITS
DRAWING / DETAIL LOCATION
DESIGNATION
SHEET NUMBER DESIGNATION
WHERE FIRST REFERENCED
DRAWING / DETAIL LOCATION DESIGNATION
SHEET NUMBER DESIGNATION WHERE SHOWN
DRAWING/DETAIL LOCATION DESIGNATION
SHEET NUMBER DESIGNATION WHERE SHOWN
SHEET NUMBER DESIGNATION WHERE SHOWN
DRAWING/DETAIL LOCATION DESIGNATION
DRAWING SCALE
ROOM TAG
A1
A-100
A1
A-100
A1
A-200
A1A-400
L1
N
1A
A1
DRAWING NAME
1/8" = 1'-0"
A-123
DRAWING DESIGNATION
ROOM
NAME
ROOM NUMBER
ROOM NAME
ELEMENT ELEVATED
EL:XX' - XX"
INDICATES TRUE NORTH
GENERAL NOTES
1. THE "CONTRACTING OFFICER" IS THE NEW YORK DISTRICT UNITED
STATES ARMY CORPS OF ENGINEERS (USACE). THE "ARCHITECT /
ENGINEER" IS JACOBS.
2. IF, AT ANY TIME, THE CONTRACTOR DISCOVERS A CONDITION WHICH
CONFLICTS WITH THE DRAWINGS AND/OR SPECIFICATION OR IF THE
CONTRACTOR DISCOVERS AN UNCLEAR OR MISLEADING DIRECTIVE GIVEN
IN THE DRAWINGS OR SPECIFICATIONS, THE CONTRACTOR SHALL BRING
THE ISSUE IMMEDIATELY TO THE ATTENTION OF THE
ARCHITECT/ENGINEER.
3. FIELD VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO
FABRICATION AND/OR CONSTRUCTION.
4. ALL WORK INDICATED ON THE DRAWINGS IS THE SOLE RESPONSIBILITY
OF THE CONTRACTOR UNLESS OTHERWISE NOTED.
5. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR MEANS AND
METHODS AND SEQUENCE OF CONSTRUCTION. THE CONTRACTOR SHALL
SOLELY AND COMPLETELY BE RESPONSIBLE FOR CONDITIONS OF THE
PROJECT ON WHICH THE WORK IS TO BE PERFORMED AND FOR THE
SAFETY OF ALL PERSONS AND/OR PROPERTY DURING THE
PERFORMANCE OF THE CONTRACT.
6. REFER TO THE PROJECT MANUAL FOR GENERAL CONTRACT
REQUIREMENTS AND SPECIFICATIONS.
7. KEYED NOTES LISTED ON DRAWINGS REFER ONLY TO THOSE KEYED
NOTE SYMBOLS ASSOCIATED WITH THE PARTICULAR DRAWING WHERE
THE KEYED NOTES ARE LISTED.
8. RESPECTIVE PLUMBING, MECHANICAL, AND ELECTRICAL
SUBCONTRACTORS SHALL PROVIDE GENERAL CONTRACTOR WITH ALL
REQUIRED ACCESS PANELS FOR GENERAL CONTRACTOR TO INSTALL IN
THE BUILDING.
9. ALL BUILDING STEEL EXPOSED AT EXTERIOR SHALL BE HOT DIPPED
GALVANIZED AND PAINTED UNLESS OTHERWISE NOTED. EXTERIOR
FRAMING MEMBERS SHALL BE HOT DIPPED GALVANIZED AND COATED
WITH A HIGH PERFORMANCE COATING. ALL INTERIOR EXPOSED STEEL
SHALL BE PAINTED UNLESS OTHERWISE NOTED.
10. THERE ARE NO ASBESTOS CONTAINING MATERIALS SPECIFIED AND THEY
SHALL NOT BE USED ON THIS PROJECT.
11. THE SITE SHALL BE AVAILABLE DURING NORMAL WORKING HOURS TO THE
CONTRACTING OFFICER AND ARCHITECT WITHOUT NOTICE.
12. THE HAUL ROUTE TO THE SITE SHALL BE COORDINATED WITH THE
CONTRACTING OFFICER.
13. ACCESS TO THE WORK AREA SHALL BE AS DIRECTED BY THE
CONTRACTING OFFICER.
14. COORDINATE THE WORK OF ALL TRADES AND CHECK ALL DIMENSIONS.
ALL DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE
ARCHITECT/ENGINEER AND SHALL BE RESOLVED BEFORE PROCEEDING
WITH THE WORK.
15. THE STRUCTURAL, MECHANICAL, PLUMBING, AND ELECTRICAL DRAWINGS
ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IF A
DISCREPANCY EXISTS BETWEEN THE ARCHITECTURAL DRAWINGS AND
ENGINEER'S DRAWINGS, SUCH DISCREPANCY SHALL BE BROUGHT TO THE
ARCHITECT/ENGINEER'S ATTENTION IN WRITING PRIOR TO INSTALLATION
OF SAID WORK. ANY WORK INSTALLED IN CONFLICT WITH THE
ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR
AT CONTRACTOR'S EXPENSE.
16. DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION.
WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED, BUT ARE OF
SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS SHALL BE
USED SUBJECT TO REVIEW BY THE ARCHITECT/ENGINEER.
17. REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS OF EXIT SIGNS AND
EMERGENCY LIGHTING.
18. RUBBER-TIRED EQUIPMENT SHALL BE USED FOR TRANSPORTING
MATERIALS AND EQUIPMENT ON PAVED SURFACES AND WITHIN THE
BUILDING. VEHICLES MOVING ON FLOOR SLABS SHALL HAVE TIRE BOOTS.
DUCT TAPE ON TIRES IS NOT ALLOWED.
19. EXPOSED CONCRETE FLOORS SHALL BE PROTECTED DURING
CONSTRUCTION AND SHALL BE FREE OF ALL CONSTRUCTION MARKERS,
STAINS, PAINTS, OIL, OR OTHER DEFECTS. PATCH, IF REQUIRED, PRIOR TO
HARDENING AND SEALING.
20. CONFINE EQUIPMENT, STORAGE OF MATERIALS, AND OPERATIONS OF
WORKERS TO LIMITS AS DIRECTED.
21. THE CONTRACTING OFFICER ASSUMES NO RESPONSIBILITY FOR DAMAGE
OR LOSS DUE TO STORING OF MATERIALS AND EQUIPMENT.
22. MANUFACTURER'S NAME AND/OR MODEL NUMBERS ARE BEING UTILIZED
FOR BASIS OF DESIGN ONLY. THE SPECIFICATION OUTLINES THE
SPECIFIC CRITERIA FOR THE EQUIPMENT OR MATERIAL AND IS NON-
PROPRIETARY.
23. MANUFACTURED MATERIALS, EQUIPMENT, ETC SHALL BE INSTALLED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND
INSTRUCTIONS/REQUIREMENTS UNLESS OTHERWISE NOTED.
24. IF DRAWINGS IN THIS SET ARE NOT 22"x 34" THEY HAVE BEEN REVISED
FROM THEIR ORIGINAL SIZE. SCALES NOTED ON PLANS AND DETAILS ARE
NO LONGER APPLICABLE.
25. PROVIDE A RED LINED "RECORD" CONSTRUCTION DOCUMENT SET AT THE
SITE. THE CONTRACTING OFFICER RESERVES THE RIGHT TO REVIEW
THESE DOCUMENTS ON A DAILY BASIS.
26. LOCATE ALL UNDERGROUND UTILITIES, ETC. PRIOR TO THE START OF
CONSTRUCTION.
27. KEEP MEANS OF EGRESS CORRIDORS PROPERLY ILLUMINATED AND FREE
OF OBSTRUCTIONS AT ALL TIMES DURING CONSTRUCTION.
28. WORK SHALL CONFORM TO APPLICABLE CODES, REGULATIONS, AND
ORDINANCES. CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING AND
OCCUPANCY PERMITS.
29. ESTABLISH A SITE BENCHMARK FOR ALL SUBCONTRACTORS TO USE. ALL
TRADES SHALL USE THE SAME BENCHMARK.
30. ITEMS INDICATED ON THE DRAWINGS AS "GFGI" MEANS GOVERNMENT
FURNISHED AND GOVERNMENT INSTALLED. COORDINATE WITH THE
GOVERNMENT FOR THE REQUIRED POWER, PLUMBING, AND OTHER
REQUIRED UTILITIES AS APPLICABLE.
31. ITEMS INDICATED ON THE DRAWINGS AS "GFCI" MEANS GOVERNMENT
FURNISHED AND CONTRACTOR INSTALLED. COORDINATE WITH ALL SCOPE
OF WORK.
32. ALL SUSPENDED ITEMS OF THE WORK EXCEEDING 31 POUNDS IN WEIGHT
(EXCLUDING DISTRIBUTED SYSTEMS SUCH AS PIPING NETWORKS) SHALL
BE ANCHORED TO RESIST A HORIZONTAL LOAD EQUAL TO 0.5 TIMES THE
COMPONENT WEIGHT IN ACCORDANCE WITH UFC 4-010-01. THIS
REQUIREMENT DOES NOT PRECLUDE REQUIREMENTS FOR SEISMIC
ANCHORAGE IN ACCORDANCE WITH ASCE 7-10 AND THE PROJECT
SPECIFICATIONS.
33. FOR LIFE SAFETY PLANS AND INFORMATION REFER TO A-100.
34. DO NOT PAINT BUILDING GROUNDING CABLES.
35. ALL PENETRATIONS THROUGH STEEL STANDING SEAM ROOF SHALL BE
COORDINATED WITH THE STEEL STANDING SEAM ROOFING
MANUFACTURER/INSTALLER TO ENSURE PENETRATIONS OCCUR
BETWEEN SEAMS.
36. MOUNT ALL PIPING, EQUIPMENT, DUCTWORK, ETC. AS HIGH AS POSSIBLE
IN ALL AREAS UNLESS OTHERWISE NOTED. ALL HANGER SUPPORTS SHALL
BE ATTACHED TO STRUCTURAL STEEL. NOTHING MAY BE SUPPORTED
FROM ROOF DECK.
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O R
K
S U
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:0
A
M
/2
/2
:1
:0
A
M
A-001
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
G E
N E
R A
L N
O T
E
FF F FF F
LIFE SAFETY PLAN LEGEND
W = CLEAR WIDTH OF LIMITING COMPONENT (in)
X = OCCUPANTS USING EXIT
Y = EXIT CAPACITY
Z = EGRESS WIDTH PER OCCUPANT (in/PERSON)
(NFPA TABLE 7.3.3.1)
TRAVEL DISTANCE: 200' - 0" MAX.
DEAD END TRAVEL DISTANCE: 50'-0" MAX.
COMMON PATH TRAVEL DISTANCE: 50'-0" MAX.
FIRE EXTINGUISHER LOCATION (GFGI)
EXIT DISCHARGE AT EXTERIOR
EXIT SIGN (ILLUMINATED) - REFER TO ELECTRICAL
X
Y
W
Z
TD = XX"
MAXIMUM NUMBER OF OCCUPANTS ACCORDING TO OCCUPANCY
(NFPA 101 TABLE 7.3.1.2 AND UFC 3-600-01; TABLE 10-1)
MECHANICAL AND ELECTRICAL
(300 SQ. FT / PERSON GROSS)
OCCUPANCY CLASSIFICATION
DE = XX"
CP = XX"
APPLICABLE CODES:
CODE VERSION
1. INTERNATIONAL BUILDING CODE (IBC) 2015
2. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
NFPA 1 FIRE CODE 2015
NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS 2015
NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS 2016
NFPA 24 STANDARD FOR THE INSTALLATION OF PRIVATE FIRE SERVICE MAINS 2016
AND THEIR APPURTENANCES
NFPA 30 FLAMMABLE AND COMBUSTIBLE LIQUIDS CODE 2015
NFPA 33 STANDARD FOR SPRAY APPLICATION USING FLAMMABLE OR 2015
COMBUSTIBLE MATERIALS
NFPA 37 STANDARD FOR THE INSTALLATION AND USE OF STATIONARY
COMBUSTION ENGINES AND GAS TURBINES 2015
NFPA 70 NATIONAL ELECTRICAL CODE 2017
NFPA 101 LIFE SAFETY CODE 2015
NFPA 110 STANDARD FOR EMERGENCY AND STANDBY POWER SYSTEMS 2016
NFPA 220 STANDARD ON TYPES OF BUILDING CONSTRUCTION 2015
3. UNIFIED FACILITIES CRITERIA (UFC)
UFC 1-200-01 DoD BUILDING CODE (GENERAL BUILDING REQUIREMENTS) CHANGE 1, 01 FEB 2018 UFC 3-230-01 WATER STORAGE, DISTRIBUTION, AND TRANSMISSION CHANGE 2, 01 JULY 2014
UFC 3-600-01 FIRE PROTECTION ENGINEERING FOR FACILITIES
CODE COMPLIANCE NOTES:
CATEGORY VALUE REFERENCE
1. OCCUPANCY CLASSIFICATIONS: UTILITY AND MISCELLANEOUS IBC SECTION 312.1
GROUP (U)
2. BUILDING TYPE: 2B IBC SECTION 602
3. ALLOWABLE NUMBER OF STORIES: U: 2 STORIES OR 55 FEET IBC TABLE 504.3 AND 504.4
4. ALLOWABLE SQUARE FOOTAGE: U: 8,500 SQ. FT. (NS) IBC TABLE 506.2
5. INCREASES DUE TO FRONTAGE: Aa = [At + (NS x If)] IBC SECTION 506.2.4, EQUATION 5-1
If = [(F/P) - 0.25] x (W/30) IBC SECTION 506.3.3, EQUATION 5-5
W = X FT. / 30 FT. IBC SECTION 506.3.2
W = 30/30 W = 1 If = [(43.33/146.66) - 0.25] x (1) If = 0.045 Aa = [8,500 + (8,500 x 0.045)] Aa = 8,886 SQ. FT.
ACTUAL VALUES:
CATEGORY VALUE
1. ACTUAL NUMBER OF STORIES 2 OR 17'-7" FEET AT RIDGE
2. ACTUAL SQUARE FOOTAGE 1,300 SQ. FT.
(TOTAL BUILDING)
FIRE RESISTIVE REQUIREMENTS: IBC TABLE 601 AND 602
BUILDING ELEMENT RATING (HOURS)
1. PRIMARY STRUCTURAL FRAME: 0
2. BEARING WALLS
A. EXTERIOR 0
B. INTERIOR 0
3. NON-BEARING WALLS AND PARTITIONS
A. EXTERIOR (TB 602)* 0
B. INTERIOR 0
4. FLOOR CONSTRUCTION AND 0
ASSOCIATED SECONDARY MEMBERS
5. ROOF CONSTRUCTION AND 0
ASSOCIATED SECONDARY MEMBERS
*FIRE SEPARATION DISTANCE TO NEAREST ADJACENT STRUCTURE X > 30 FT
MEANS OF EGRESS:
CATEGORY VALUE REFERENCE
1. EGRESS WIDTH PER
OCCUPANT SERVED (INCH/PERSON)
OTHER EGRESS (NON-SPRINKLERED) 0.20 NFPA 101 7.3.3.1
2. CLEAR MINIMUM EXIT WIDTH 32 INCHES NFPA 101 7.2.1.2.3
3. MINIMUM MEANS OF EGRESS WIDTH 36 INCHES NFPA 101 7.3.4.1 (2)
4. MAXIMUM TRAVEL DISTANCES:
STORAGE (UTILITY/NON-SPRINKLERED) 200 FT. NFPA 101 TB A.7.6
5. COMMON PATHS OF EGRESS TRAVEL:
UTILITY (NON-SPRINKLERED) 50 FT. NFPA 101 TB A.7.6
6. DEAD END MAXIMUM LENGTH:
UTILITY (NON-SPRINKLERED) 50 FT. NFPA 101 TB A.7.6
STORAGE
(500 SQ. FT / PERSON GROSS)
478 SF
GENERATOR
ROOM
329 SF
ELECTRICAL
ROOM
270 SF
FILE
STORAGE
ROOM
34.75
0.2
68.75
0.2
68.75
0.2
T R
A V
E L
D
IS
T A
N C
E
1'
6"
0"
0'
-0
C P
T R
A V
E L
D
IS
T A
N C
E
2'
4"
0'
-0
C P
T R
A V
E L
D
IS
T A
N C
E
3'
4"
0'
-0
C P
3'
0"
478 SF
GENERATOR
ROOM
Option Conflict
ELECTRICAL
ROOM
34.75
0.2
68.75
0.2
T R
A V
E L
D
IS
T A
N C
E
1'
6"
0"
T R
A V
E L
D
IS
T A
N C
E
2'
4"
0"
T R
A V
E L
D
IS
T A
N C
E
2'
7"
0"
192 SF
FILE
STORAGE
ROOM
65 SF
TOILET
THIS AREA SHALL
BE CLASSIFIED
AS A "WET AREA"
68.75
0.2
KEYED NOTE
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:1
A
M
/2
/2
:1
:1
A
M
A-100
G . S
T A
U D
E R
K . B
A N
K S
J.
F
O U
LK
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
L
IF
E S
A F
E T
Y P
L A
N S
1/4" = 1'-0"A1
LIFE SAFETY FLOOR PLAN - BDR 3
1/4" = 1'-0"
2' 4' 8' 12'
NN
BDR 2BDR 3
1/4" = 1'-0"A4
LIFE SAFETY FLOOR PLAN - BDR 2
A-001 A-001
2 MECHANICAL EQUIPMENT - REFER TO MECHANICAL
11 THIS PARTITION IS A 1-HOUR, FIRE RATED ASSEMBLY – PROVIDE TOP OF
WALL AND THROUGH-PENETRATION FIRE-STOPPING AT ALL JOINTS AND
PENETRATIONS
A-201
B4
A-201
B1
A-201
A1
A-201
A4
43' - 4"
3'
4" 2'
8"
6'
4"
2'
0"
3'
4" 2'
4"
7' - 0" 6' - 4" 8' - 8" 9' - 0" 4' - 4"
10' - 6" 12' - 8" 17' - 6"
GENERATOR
ROOM
ELECTRICAL
ROOM
FILE
STORAGE
ROOM
A4
A-301
A4
A-301
C4
A-301
C4
A-301
A1
A-301
A1
A-301
C1
A-301
C1
A-301
101B
3B
101C103A
3'
4" 8"
7' - 4 1/2" ±
PER MANUF.
5' - 3" ± 4' - 10 1/2" ±
101A
71717171
1'
6" 3' - 6"
L-5 L-4
L-4
L-3
L-2
SIMILAR
SIMILAR
SIMILAR
SIMILAR
SIMILAR
SIMILAR
3'
6"
6'
0" R
E F
E R
T O
C
IV
IL
REFER TO CIVIL
91' - 8" 6' - 4"
6' - 0" 2' - 0" 8' - 8" 2' - 8" 10' - 0" 10' - 0" 4' - 0"
L-7L-7
10 10
FLOOR PLAN GENERAL NOTES
1. REFER TO B2/A-601 FOR TYPICAL TOILET ACCESSORIES MOUNTING
HEIGHTS.
2. PLUMBING FIXTURES ARE IDENTIFIED AT INTERIOR ELEVATIONS ON
SHEET A-601.
A-201
B1
A-201
A1
A-201
A4
A4
A-301
A4
A-301
C4
A-301
C4
A-301
A1
A-301
A1
A-301
C1
A-301
C1
A-301
GENERATOR
ROOM
ELECTRICAL
ROOM
TOILET
A-601
C1
C2
C3
FILE
STORAGE
ROOM
7'
/8
NOTE: REFER TO A1/A-101
FOR TYPICAL NOTES
0H
8"
1'
4"
43' - 4"
7' - 0" 6' - 4" 8' - 8" 9' - 0" 4' - 4"
6' - 0" 2' - 0" 8' - 8" 2' - 8" 10' - 0" 10' - 0" 4' - 0"
1'
6"
3' - 6"
A-201
B4
SIMILAR
3B
103A 101C
101A
101B
1'
5"
7' - 4 1/2" ±
PER MANUF.
5' - 3" ± 4' - 10 1/2" ±
3'
4" 8"
9' - 4" 13' - 10" 17' - 6"
L-5 L-4
L-4
L-3
L-2
3'
4" 2'
8"
6'
4"
2'
0"
3'
4" 2'
4"
1' - 8" 6' - 4"6'
0" R
E F
E R
T O
C
IV
IL
REFER TO CIVIL
3'
6"
L-7 L-7
L-6
OJ
10 10
3 3
90 90
71 71
KEYED NOTE
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:1
A
M
/2
/2
:1
:1
A
M
A-101
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
F L O
O R
P L A
N S
1/4" = 1'-0"A1
FLOOR PLAN - BDR 3
1/4" = 1'-0"
2' 4' 8' 12'
71 BOLLARD (TYPICAL) - ALIGN TANGENT WITH FACE OF JAMB - REFER TO
A5/A-531
90 BRICK VENEER EXPANSION JOINT - REFER TO B1/A-601 (SIMILAR)
94 WALL HYDRANT - REFER TO PLUMBING.
2 MECHANICAL EQUIPMENT - REFER TO MECHANICAL
3 FIRE EXTINGUISHER ON BRACKET (GFGI)
5 FLOOR DRAIN / CLEAN OUT - REFER TO PLUMBING
6 PIPING CHASE - REFER TO PLUMBING
7 ELECTRICAL EQUIPMENT - REFER TO ELECTRICAL AND MECHANICAL
8 FUEL TANK PAD - REFER TO CIVIL. FUEL TANK - REFER TO MECHANICAL
9 EXTERIOR CONCRETE DOOR STOOP
10 CONCRETE MASONRY UNIT (CMU) WALL, TYP - REFER TO STRUCTURAL,
SF-101 & SF-102 FOR REINFORCING AND DETAILS
NN
BDR 2BDR 3
1/4" = 1'-0"A4
FLOOR PLAN - BDR 2
A-001 A-001
STAUDEGM
Text Box
8 FUEL TANK PAD - REFER TO C-501, C-503 AND SF002
1'
4"
1' - 4"
1'
4"
1' - 4"
NOTE:
PARTITION AND UNIT
HEATER SCHEDULED
TO OCCUR ONLY AT
BDR 2.
50505050
46' - 6"
:1
:1
3:12
3:12
REFLECTED CEILING PLAN GENERAL NOTES
1. REFER TO PLUMBING, MECHANICAL, AND ELECTRICAL FOR ALL VENTS,
GRILLES, REGISTERS, DIFFUSERS, DUCTS, LIGHTS, DETECTORS, ETC. AND
COORDINATE SAME AS REQUIRED.
2. COORDINATE ALL STRUCTURAL, PLUMBING, MECHANICAL, AND
ELECTRICAL WORK WITH EXPOSED CEILING HEIGHTS AND
ARCHITECTURAL WORK. WHERE CONFLICTS IN DEVICES OCCUR,
COORDINATE FINAL LOCATIONS WITH ARCHITECT.
3. EXTEND ALL PARTITIONS TO BOTTOM OF ROOF DECK (TYPICAL) UNLESS
OTHERWISE NOTED.
4. REFER TO ROOM FINISH SCHEDULE ON A-601 FOR EXPOSED CEILING
FINISHES.
5. NOTIFY ARCHITECT / ENGINEER OF ALL ITEMS NOT SHOWN ON REFLECTED
CEILING PLAN AND LOCATE PER ARCHITECT / ENGINEER DIRECTION.
6. SUPPORT PENDANT MOUNTED LIGHT FIXTURES DIRECTLY FROM THE
STRUCTURE ABOVE WITH HANGER WIRES OR CABLES PASSING THROUGH
EACH PENDANT HANGER AND CAPABLE OF SUPPORTING FOUR (4) TIMES
THE WEIGHT OF THE FIXTURE.
7. REFER TO ELECTRICAL FOR LIGHTING FIXTURES TYPE AND SIZE.
ROOF PLAN GENERAL NOTES
1. FOR TYPICAL ROOF DETAILS REFER TO A-531.
2. ALL STEEL STANDING SEAM ROOFING IS 2 1/4" BATTEN SEAM - REFER TO
A3/A-501 FOR TYPICAL COMPOSITION OF SHEET METAL ROOFING.
3. ALL ROOF SYSTEMS SHALL BE FURNISHED AND INSTALLED PER ROOF
MANUFACTURER'S INSTRUCTIONS AND STANDARDS.
4. NOT ALL PLUMBING, MECHANICAL, ELECTRICAL, ETC. ITEMS MOUNTED ON
OR PENETRATING ROOF MAY BE SHOWN. REFER TO RESPECTIVE PLANS
FOR LOCATIONS. PENETRATIONS, ETC. THROUGH ROOF SYSTEM SHALL
COMPLY WITH ROOF MANUFACTURER'S PRINTED INSTRUCTIONS AND
STANDARDS.
5. ALL WORK AND MATERIALS BELONGING TO AND ADJACENT TO ROOF
SHALL BE IN FULL COMPLIANCE WITH ROOF MANUFACTURER'S STANDARD
INSTALLATION DETAILS AND WARRANTY.
6. STAGGER ALL ROOF INSULATION JOINTS. ALL INSULATION JOINTS
GREATER THAN 1/4" SHALL BE FILLER WITH INSULATION STRIPS.
7. AT ALL ROOF PENETRATIONS, FILL AIR GAPS WITH SPRAY FOAM
INSULATION TO MAINTAIN AIR TIGHTNESS.
8. ROOF SHALL HAVE A CONTINUOUS MINIMUM VALUE OF R-30 INSULATION.
9. FOR LIGHTNING PROTECTION AIR TERMINAL LOCATIONS, REFER TO
ELECTRICAL.
11. FOR LOCATION OF VENT THROUGH ROOF, REFER TO PLUMBING .
12. ALL COUNTER FLASHING AND MISCELLANEOUS METAL FLASHING SHALL
HAVE ELASTOMERIC SEALANT APPLIED AT END CONDITIONS.
13. ALL EXPOSED FASTENERS SHALL BE CORROSION RESISTANT.
14. ALL STEEL STANDING SEAM ROOF PANELS SHALL BE FIELD FORMED AND
SHALL BE WITHOUT LAPS. ALL DIMENSIONS SHALL BE FIELD VERIFIED
PRIOR TO FABRICATION / INSTALLATION.
15. NO WORK, INCLUDING STAGING OR ACCESS TO OTHER PORTIONS OF THE
WORK SHALL BE PERMITTED ON THE STEEL STANDING SEAM ROOFS.
16. ALL ROOFING SHALL COMMENCE AT THE FURTHEST POINT FROM THE
WORKERS ACCESS AND PROGRESS BACK TOWARDS THE ACCESS POINT.
17. ALL CLARIFICATIONS OR ADDITIONAL INFORMATION REQUIRED SHALL BE
IN ACCORDANCE WITH CRITERIA AND DETAILS OF THE NRCA ROOFING
AND WATER PROOFING MANUAL. ANY DEVIATION FROM THE SPECIFIED
OR INDICATED REQUIREMENTS SHALL BE SUBMITTED FOR APPROVAL BY
ARCHITECT PRIOR TO INSTALLATION.
18. ALL ROOF SYSTEMS AND COVER BOARD ANCHORAGE FASTENERS AND
SCREWS SHALL PENETRATE THE TOP OF THE ROOF DECK.
KEYED NOTE REFLECTED CEILING PLAN LEGEND
LIGHTING FIXTURE - REFER TO ELECTRIAL
EXIT SIGN (DARKEN AREA DENOTES LIGHTED FACE) -
REFER TO ELECTRICAL
UNIT HEATER - REFER TO MECHANICAL AND ELECTRICAL
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:1
A
M
/2
/2
:1
:1
A
M
A-111
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
R O
O F
P L A
N A
N D
R E
F L E
C T
E D
C E
IL
IN
G P
L A
N
1/4" = 1'-0"A4
REFLECTED CEILING PLAN - BDR 2 AND BRD 3
1/4" = 1'-0"A1
ROOF PLAN - BDR 2 AND BRD 3
1/4" = 1'-0"
2' 4' 8' 12'
NN
BDR 2BDR 3
31 EXPOSED STRUCTURE - PAINTED, TYPICAL
32 MECHANICAL UNIT HEATER - REFER TO MECHANICAL
46 VENTILATED ALUMINUM SOFFIT
50 BATTEN SEAM METAL ROOFING
51 GENERATOR EXHAUST THROUGH ROOF - REFER TO MECHANICAL. LOCATE
THE EXHAUST AS HIGH AS POSSIBLE ON ROOF
52 RIDGE VENT - REFER TO B3/A-531
53 VENT THROUGH ROOF - REFER TO D3/A-531 AND PLUMBING OR
MECHANICAL
EXTERIOR FINISH SCHEDULE REMARKS:
1. REFER TO MECHANICAL
2. REFER TO ELECTRICAL
3. REFER TO PLUMBING
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10" 13' - 4"14' - 8"14' - 0"
90 90
7272 7373
2" 7'
4"
1'
4"
3:12 3:12
93 93
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10" 17' - 8" 11' - 0" 1' - 4"
717171
1'
4" 7'
4"
2"
3' - 4"
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10" 1' - 4"
8989 88
71 71 71 71
73 73
1'
4" 7'
4"
2"
3:12 3:12
6' - 4"
2'
0"
93 93
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
2"
12 3
14' - 0" 14' - 8" 1' - 4"
90 90
1'
4" 7'
4"
2"
KEYED NOTE
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:1
A
M
/2
/2
:1
:1
A
M
A-201
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
E X
T E
R
IO
R E
L E
V A
T
IO
N S
EXTERIOR FINISH COLOR SCHEDULE
ELEVATION
KEYED NOTE PRODUCT FINISH COLOR REMARKS
2 MECHANICAL EQUIPMENT PREFINISHED 1
50 STEEL STANDING SEAM ROOF SYSTEM PREFINISHED
51 GENERATOR EXHAUST PREFINISHED 1, 2
52 RIDGE VENT PREFINISHED MATCH STEEL STANDING SEAM ROOF
71 BOLLARD FIELD PAINTED SAFETY YELLOW
72 BRICK VENEER - COLOR A PREFINISHED
73 BRICK VENEER - COLOR B PREFINISHED
74 CONCRETE FOUNDATION --
87 LOUVER PREFINISHED
88 OVERHEAD COILING DOOR PREFINISHED
89 HOLLOW METAL DOOR AND FRAME FIELD PAINTED
90 MASONRY CONTROL JOINT PREFINISHED
93 WALL MOUNTED LIGHT FIXTURE PREFINISHED 2
94 WALL HYDRANT PREFINISHED 3
1/4" = 1'-0"
A-101
B1
EXTERIOR ELEVATION
1/4" = 1'-0"
A-101
B4
EXTERIOR ELEVATION
1/4" = 1'-0"
A-101
A1
EXTERIOR ELEVATION
1/4" = 1'-0"
A-101
A4
EXTERIOR ELEVATION
1/4" = 1'-0"
2' 4' 8' 12'
74 FINISH GRADE (TYPICAL) - HOLD 2-INCHES BELOW BRICK MASONRY
86 LOUVER - REFER TO FLOOR PLANS AND A-603
87 LOUVER - REFER TO FLOOR PLANS AND A-604
88 OVERHEAD COILING DOOR
89 HOLLOW METAL DOOR AND FRAME WITH INTEGRAL LOUVER
90 BRICK VENEER EXPANSION JOINT - REFER TO B1/A-601 (SIMILAR)
93 LIGHT FIXTURE - REFER TO ELECTRICAL SCHEDULE
94 WALL HYDRANT - REFER TO PLUMBING.
8 FUEL TANK PAD - REFER TO CIVIL. FUEL TANK - REFER TO MECHANICAL
50 BATTEN SEAM METAL ROOFING
51 GENERATOR EXHAUST THROUGH ROOF - REFER TO MECHANICAL. LOCATE
THE EXHAUST AS HIGH AS POSSIBLE ON ROOF
52 RIDGE VENT - REFER TO B3/A-531
71 BOLLARD (TYPICAL) - ALIGN TANGENT WITH FACE OF JAMB - REFER TO
A5/A-531
72 BRICK VENEER - COLOR A
73 BRICK VENEER - COLOR B - TYPICAL ACCENT BAND AROUND PERIMETER OF
BUILDING
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
A-501
A5
A-501
A4
SIMILAR
OPPOSITE
HAND
TOILET
FILE
STORAGE
ROOM
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
A-501
A4
GENERATOR
ROOM
A-604
C4
OPPOSITE
HAND
A-604
A4
OPPOSITE
HAND
2 77 76
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
A-501
A3
ELECTRICAL
ROOM
GENERATOR
ROOM
A-501
A4 SIMILAR
OPPOSITE
HAND
FILE
STORAGE
ROOM
31 51 2
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
GENERATOR
ROOM
ELECTRICAL
ROOM
A-501
A4
SIMILAR
A-501
A3 SIMILAR
OPPOSITE
HAND
TOILET
2 76 77
KEYED NOTE
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:2
A
M
/2
/2
:1
:2
A
M
A-301
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
B U
IL
D
IN
G
S E
C T
IO
N
S
1/4" = 1'-0"
2' 4' 8' 12'
1/4" = 1'-0"
A-101
A4
BUILDING SECTION
1/4" = 1'-0"
A-101
C4
BUILDING SECTION
1/4" = 1'-0"
A-101
A1
BUILDING SECTION
1/4" = 1'-0"
A-101
C1
BUILDING SECTION
75 PENDANT LIGHTING FIXTURE, SEE LIGHTING SCHEDULE
76 CONCRETE MASONRY UNIT (CMU) WALL
77 CONCRETE SLAB
2 MECHANICAL EQUIPMENT - REFER TO MECHANICAL
8 FUEL TANK PAD - REFER TO CIVIL. FUEL TANK - REFER TO MECHANICAL
31 EXPOSED STRUCTURE - PAINTED, TYPICAL
51 GENERATOR EXHAUST THROUGH ROOF - REFER TO MECHANICAL. LOCATE
THE EXHAUST AS HIGH AS POSSIBLE ON ROOF
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
NOTE:
FOR TYPICAL NOTES REFER TO A3/A-501
A-501
A1
A-604
C1
A-604
B1
A-501
C1
SIMILAR
SIMILAR
3:12
LOUVER - REFER TO A-604 AND
MECHANICAL
RIGID INSULATION: R-15, FULL-
PERIMETER OF BUILDING, TO 24
INCHES IN WIDTH, TYP.
RIGID INSULATION: R-75, FULL-
PERIMETER OF BUILDING, FROM
SLAB TO FOOTING, TYP.
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
GRADE
EL: 99' - 10"
8" CMU WALL - REFER TO STRUCTURAL
2" (R-9.5 MINIMUM) THERMAL INSULATION
2 3/4" AIR SPACE
VENEER TIES
BRICK VENEER - COLOR A
SLAB ON GRADE CONCRETE -
REFER TO STRUCTURAL
CONCRETE FOUNDATION WALL AND
FOOTING - REFER TO STRUCTURAL
SITE PAVEMENT - REFER TO CIVIL
BATTEN-SEAM METAL ROOFING SYSTEM
SELF-ADHERING HIGH TEMPERATURE
UNDERLAYMENT OVER ALL COVER BOARD
1/2" COVER BOARD
6" (R-30 MINIMUM) THERMAL INSULATION
ROOF DECK - REFER TO STRUCTURAL
A-501
A1
1'
4" 7'
1/
2"
BRICK VENEER - COLOR B
A-501
C1
3:12FRAMING - REFER TO STRUCTURAL
FLUID-APPLIED AIR BARRIER
RIGID INSULATION: R-15, FULL-PERIMETER
OF BUILDING, TO 24 INCHES IN WIDTH, TYP.
RIGID INSULATION: R-75, FULL-PERIMETER
OF BUILDING, FROM SLAB TO FOOTING, TYP.
FINISH FLOOR
EL: 100' - 0"
GRADE
EL: 99' - 10"
1/2" CONCRETE EXPANSION JOINT
AND SEALANT
CONCRETE FOUNDATION WALL -
REFER TO STRUCTURAL
HEMMED 26 GAGE STAINLESS STEEL
FLASHING WITH DRIP EDGE SET IN
CONTINUOUS BEAD OF SEALANT - PLACE
SEALANT ON HORIZONTAL SURFACE
MASONRY WEEP VENTILATORS AT
32" OC UNLESS OTHERWISE NOTED
FLEXIBLE FLASHING - LAP STAINLESS STEEL
FLASHING 4" MINIMUM AND SEAL IN MASTIC
CAVITY DRAINAGE MATERIAL
2" (R-9.5 MINIMUM) THERMAL INSULATION
MASONRY VENEER TIES
4"
2"
FLUID-APPLIED AIR BARRIER
RIGID INSULATION: R-15, FULL-PERIMETER
OF BUILDING, TO 24 INCHES IN WIDTH, TYP.
RIGID INSULATION: R-75, FULL-PERIMETER
OF BUILDING, FROM SLAB TO FOOTING, TYP.
FINISH FLOOR
EL: 100' - 0"
T.O. MASONRY
EL: 112' - 0"
A-604
C1
A-603
B1
A-501
C1
SIMILAR
NOTE:
FOR TYPICAL NOTES REFER TO A3/A-501
3:12
HOLLOW METAL DOOR AND
FRAME WITH INTEGRAL
LOUVER TRANSOM - REFER
TO A-603
SITE PAVEMENT SLOPED UP
TO DOOR SILL - REFER TO
CIVIL
A-603
B3
SIMILAR
RIGID INSULATION: R-15, FULL-
PERIMETER OF BUILDING, TO
24 INCHES IN WIDTH, TYP.
RIGID INSULATION: R-75, FULL-
PERIMETER OF BUILDING,
FROM SLAB TO FOOTING, TYP.
T.O. MASONRY
EL: 112' - 0"
ROOF FRAMING AND CONNECTIONS -
REFER TO STRUCTURAL - CMU
SHALL BE CUT AS REQUIRED AND
CONTINUE BETWEEN FRAMING
BATTEN-SEAM METAL
ROOF OVER ROOF
DECK TURNED DOWN
TO BOTTOM OF SOFFIT
2-1/2" (16 GAGE) COLD-FORMED
METAL FRAMING AT 24" O.C.
1 1/2" HAT CHANNELS FASTENED
TO COLD-FORMED METAL FRAMING
PREFINISHED VENTILATED
ALUMINUM SOFFIT
6"x6"x1/4" BENT PLATE (INTERIOR AND EXTERIOR)
WITH BATT INSULATION TO FILL VOID BETWEEN
FRAMING - TYPICAL AROUND PERIMETER
BATTEN-SEAM METAL
ROOF SYSTEM TRIM AND
FLASHING ACCESSORIES
1'
/1 6"
3 7/16"
3:12
CONTINUOUS PERIMETER
STEEL BENT PLATE -
REFER TO STRUCTURAL
BATTEN-SEAM CAP - CUT RIBS,
FIELD BEND ROOF PANELS, AND
SEAL TO CONFIGURATION AND
ANGLE INDICDATED
FOAMED-IN-PLACE INSULATION IN ROOF DECK
RIBS IN PLANE WITH WALL CAVITY THERMAL
INSULATION (WHERE EXPOSED, INSULATION
SHALL BE COVERED WITH A THERMAL BARRIER)
FLUID-APPLIED AIR BARRIER
A-531
C2
2' C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:2
A
M
/2
/2
:1
:2
A
M
A-501
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
E X
T E
R
IO
R W
A L L S
E C
T
IO
N S
A N
D D
E T
A
IL
S
3/4" = 1'-0"
A-301
A4
WALL SECTION
3/4" = 1'-0"
A-301
A3
WALL SECTION
1 1/2" = 1'-0"
A-501
A1
EXTERIOR DETAIL
0 2'
1 1/2" = 1'-0"
6" 1'
0 2'
3/4" = 1'-0"
6" 1' 4'
3/4" = 1'-0"
A-301
A5
WALL SECTION
1 1/2" = 1'-0"
A-501
C1
EXTERIOR DETAIL
4" NON-SHRINK GROUT
CONVEX FORMED CAP
6" DIAMETER (NOMINAL)
GALVANIZED SCHEDULE 80
PIPE FILL WITH CONCRETE
TO WITHIN 4" OF TOP OF PIPE
18" DIAMETER
CONCRETE PIER
COMPACTED FILL
PROVIDE FOUR 1/2"
DIAMETER x 3" LONG RODS
WELDED TO PIPE BOLLARD
CONCRETE FILL
7"
3' -0
4"
3' -0
EXTERIOR PAVING -
REFER TO CIVL
SHAPE GROUT DOME
WITH PREFORMED
SMOOTH CUP TO ACHIEVE
SHAPE INDICATED
3/ 4"
NOTE:
REFER TO FLOOR PLANS ON
A-101 FOR LAYOUT AT DOORS
WRAP CONTINUOUS UNDERLAYMENT
AROUND PIPE TO MAINTAIN
CONTINUOUS AIR BARRIER
CUT PANEL 1" CLEAR AROUND
PIPE FOR EXPANSION
1/2" COVER BOARD
SECURE FLUE TO
STRUCTURE BELOW ROOF
TURN DOWN PANEL
EDGE TO STIFFEN
BATTEN-SEAM
METAL ROOF
PIPE, REFER TO PLUMBING -
PAINT TO MATCH COLOR OF
BATTEN-SEAM METAL ROOF
NOTE: THIS DETAIL IS THE
EXCEPTION TO DETAIL D3/A-531
AND SHALL NOT BE USED
EXCEPT WITH WRITTEN
AGREEMENT BY ARCHITECT
PIPE, REFER TO PLUMBING
PIPE BOOT SET IN
CONTINUOUS BED OF SEALANT
TURN SEAM DOWN
SET IN SEALANT
WRAP CONTINUOUS UNDERLAYMENT
AROUND PIPE TO MAINTAIN
CONTINUOUS AIR BARRIER
BATTEN-SEAM METAL ROOF
SEALANT, REFER TO EAVE
CONDITIONS; END
CLOSURE DETAIL
TURN DOWN PANEL EDGE TO
STIFFEN OPENING
1/2" COVER BOARD
CUT PANEL 1" CLEAR AROUND
PIPE FOR EXPANSION
SECURE FLUE TO STRUCTURE
BELOW ROOF
FLATTEN PANEL RIBS AT POINT OF
INTERSECTION TO ALLOW BOOT TO
NEST FLAT AGAINST PANEL PAN
CLAMPING RING, TYPICALFOR SECTION THROUGH FLUE REFER
TO D3/A-531
PROVIDE CONTINUOUS SEALANT UNDER
BOOT PERIMETER -FASTEN PER
MANUFACTURER'S RECOMMENDATIONS
BUT MAXIMUM 3" OC
PRE-MANUFACTURED,
WEATHERPROOF, FLEXIBLE PIPE
FLASHING TO 6-INCHES ABOVE
ROOFING. COLOR OF FLASHING TO
MATCH ROOFING, TYPICAL.
FOR SECTION THROUGH
FLUE REFER TO D5/A-531
FLAT STOCK PANEL CUT TO
ALLOW FOR EXPANSION AROUND
PIPE, COLOR SHALL MATCH ROOF
PROVIDE CONTINUOUS SEALANT
UNDER BOOT PERIMETER -FASTEN PER
MANUFACTURER'S RECOMMENDATIONS
BUT MAXIMUM 3" OC
FLATTEN PANEL RIBS AROUND
CUT OPENING TO ALLOW FLAT
STOCK TO SEAL TIGHT AGAINST
PANEL PAN UNDERSIDE
SET FLAT STOCK PANEL IN
CONTINUOUS BED OF SEALANT
AROUND ENTIRE CUT OUT
OPENING IN PANELS. RIVETS
SHALL BE COMPLETELY
SEALED.
CLAMPING RING, TYPICAL
PRE-MANUFACTURED,
WEATHERPROOF, FLEXIBLE PIPE
FLASHING TO 6-INCHES ABOVE
ROOFING. COLOR OF FLASHING
TO MATCH ROOFING, TYPICAL.
FACTORY APPLIED BUTYL SEALANT
MANUFACTURER'S
RECOMMENDED STAINLESS
STEEL CLIP SYSTEM
BATTEN-SEAM METAL ROOF PANEL
TOP OF COVER BOARD
CONTINUOS BATTEN CAP SHALL MATCH
ROOF PANEL FINISH AND COLOR
1/
4"
/1 6"
VENTED SPACE: KEEP CAVITY
CLEAR OF ALL DEBRIS. DO NOT
BLOCK CAVITY WITH ANYTHING
THAT MAY RESTRICT AIR FLOW.
STANDING SEAM FASTENERS
AND WASHERS - ANCHOR
THROUGH TO STEEL DECK
BELOW - TYPICAL
FIELD REMOVE HEM
OF LOWER FLASH
RIDGE FLASH
SECTION VIEW
MINIMUM 4" NOTCH AND LAP
DO NOT INSTALL
FASTENERS
INTO BATTENS
NON-CURING
BUTYL (MINIMUM
TWO BEADS)
RIDGE FLASHING
RIDGE
RIDGE FLASHING CAP
REFER TO A3/A-531
PANNED PANEL POINT
FASTENER - DO NOT
INSTALL INTO BATTEN
PREFORMED METAL HEAD
CLOSURE TRIM WITH NEOPRENE
BLOCK SET IN SEALANT
WORKING POINT
ROOF DECK - REFER
TO STRUCTURAL
1/2" COVER BOARD
ROOF INSULATION
PANEL
FASTENERS PER MANUFACTURER'S
RECOMMENDATIONS
PANEL CLIP
FOAMED-IN-PLACE INSULATION WITH
INTUMESCENT PAINT AS THERMAL BARRIER 1 3/8" 1 3/8"
ENHANCED SNOW SCREEN
HEAVY FELT PAPER OR
WATERPROOF MEMEBRANE
CONTINUOUS RIDGE VENT CAVITY: KEEP CAVITY
CLEAR OF ALL DEBRIS. DO NOT BLOCK CAVITY WITH
ANYTHING THAT MAY RESTRICT AIR FLOW
FASTEN EACH COURSE TO LOWER
COURSE WITH #10 X 3 1/2", COURSE
AUGER THREAD SCREWS AT 12
INCHES O.C. EACH SIDE;TYP
BENT STEEL PLATE WELDED TO
ROOF JOIST FLANGES; REFER TO
STRUCTURAL
CONTINOUS 2X8 WOOD LUMBER
NAILER (TYP). ANCHORED TO
BENT STEEL PLATE; COURSES
CUT AN STACKED TO MATCH
STEEL PLATE PROFILE
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:2
A
M
/2
/2
:1
:2
A
M
A-531
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
E X
T E
R
IO
R D
E T
A
IL
S
1 1/2" = 1'-0"A5
BOLLARD DETAIL
A-101
FULL SCALE
0 1" 2" 3"
1 1/2" = 1'-0"D3
PIPE PENETRATION DETAIL
1 1/2" = 1'-0"D5
PIPE PENETRATION DETAIL
1 1/2" = 1'-0"C3
PIPE PENETRATION DETAIL
1 1/2" = 1'-0"C5
PIPE PENETRATION DETAIL
A-531A-531
12" = 1'-0"D2
BATTEN-SEAM METAL ROOFING PANEL JOINT DETAIL
1 1/2" = 1'-0"A3
BATTEN-SEAM RIDGE DETAIL
1 1/2" = 1'-0"B3
BATTEN-SEAM RIDGE DETAIL
A-111
A-531
NOT TO SCALE NOT TO SCALE
NOT TO SCALE NOT TO SCALE
NOT TO SCALE
A-531A-111
A-111
0 2'
1 1/2" = 1'-0"
6" 1'
3" = 1'-0"
A-501
C2
SECTION_DET_EXT_CMU/BRICK_CORNER BLOCKING
DETAIL
ROOM FINISH SCHEDULE GENERAL NOTES
1. REFER TO PLANS FOR PARTITION TYPES.
2. PAINT ALL STEEL DOORS AND FRAMES.
3. ALL FINISHES SHALL BE APPROVED BY THE NEW YORK CORPS OF
ENGINEERS PRIOR TO INSTALLATION.
4. FOR EXTERIOR COLOR SCHEDULE REFER TO DRAWING A-201.
5. ALL EXPOSED PIPING SHALL BE PAINTED.
6. PAINT ALL EXPOSED STEEL, BRACES, GIRTS, DECKS, AND
MISCELLANEOUS FRAMING STEEL UNLESS OTHERWISE NOTED.
ROOM FINISH SCHEDULE LEGEND
FLOORS
CONC CONCRETE
SEAL SEALED CONCRETE
WALLS / PARTITIONS
CMU CONCRETE MASONRY UNIT
-- NONE
P PREFINISHED
PT PAINT
CEILINGS
EXP EXPOSED STRUCTURE
-- NONE
VAR VARIES
P PREFINISHED
PT PAINT
0H 7 5/8" (8" NOMINAL) PARTITION
DESIGN: N/A
TEST NO.: N/A
SCALE: 1 1/2"=1'-0"
FIRE RATING: N/A
STC RATING: N/A
HEAD
PLAN
BASE
8" (NOMINAL) CMU
STEEL REINFORCING, TYP -
REFER TO STRUCTURAL
DRAWINGS
PROVIDE COMPRESSIBLE,
CLOSED-CELL, FOAM
INSULATION INFILL BETWEEN
TOP OF PARTITION AND
UNDERSIDE OF STRUCTURAL
DECK/FRAME.
KEEP 1 1/2" THICK
SEPARATION
ROOF STRUCTURE, TYP.
BRACE CMU PARTITION TO
STRUCTURE AS DETAILED,
A3/SF-102
(TTD)
(M-SS)
(LAV)
(WC)
(PTD)
(SD)
3/8"
1/ 2"
OPEN CELL POLYURETHANE
FOAM BACKER ROD FRICTION-
FITTED INTO JOINT OPENING,
RECESSED 1/2" FROM SURFACE
SEALANT APPLIED OVER
FORMING MATERIAL TO A
MINIMUM THICKNESS OF 1/2"
PRIME SIDES OF MASONRY
JOINT PRIOR TO INSTALLATION
OF JOINT ASSEMBLY
PREMOULDED FOAM PAD OR
NEOPRENE PAD EXTEND TO
VENEER CAVITY
MASONRY - CMU OR BRICK
VENEER WHERE OCCURS
(WC) WATER CLOSET
FLOOR MOUNTED
TOP OF
SEAT
(TTD) TOILET TISSUE
DISPENSER
WALL MOUNTED
(LAV) LAVATORY
WALL HUNG
2'
(PTD) PAPER TOWEL
DISPENSER
WALL MOUNTED
(SD) SOAP DISPENSER
WALL MOUNTED
3'
8"
(M-SS) MIRROR
POLISHED STAINLESS STEEL
WALL MOUNTED
CENTER
MIRROR ON
LAVATORY
NOTE:
DIMENSION IS
TO BOTTOM OF
REFLECTIVE
SURFACE
3'
4"
PUSH
BUTTON
MID SPOUT
2'
/1 6"
1' - 5"
1'
3"
3'
8"
ADJACENT WALL
KEYED NOTE
0J 3 5/8" (4" NOMINAL) PARTITION
DESIGN: N/A
TEST NO.: N/A
SCALE: 1 1/2"=1'-0"
FIRE RATING: N/A
STC RATING: N/A
HEAD
PLAN
BASE
4" (NOMINAL) CMU
PROVIDE COMPRESSIBLE,
CLOSED-CELL, FOAM
INSULATION INFILL BETWEEN
TOP OF PARTITION AND
UNDERSIDE OF STRUCTURAL
DECK/FRAME.
KEEP 1 1/2" THICK
SEPARATION
ROOF STRUCTURE, TYP.
BRACE CMU PARTITION TO
STRUCTURE AS DETAILED,
A3/SF-102
STEEL REINFORCING, TYP -
REFER TO STRUCTURAL
DRAWINGS
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:2
A
M
/2
/2
:1
:2
A
M
A-601
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
R O
O M
F
IN
IS
H
S C
H E
D U
L E
P
A R
T
IT
IO
N
T Y
P E
S
IN
T
E R
IO
R
E L E
V A
T
IO
N S
ROOM FINISH SCHEDULE - BRD 3
ROOM
NO. NAME
FLOORING BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
CEILING
HIEGHT REMARKS
SUBSTRATE
MATERIAL
FLOORING
SYSTEM
FLOORING
COLOR
SUBSTRATE
MATERIAL BASE SYSTEM BASE COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
101 GENERATOR ROOM CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 -- EXP PT-2 VAR
102 ELECTRICAL ROOM CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 -- EXP PT-2 VAR
103 FILE STORAGE ROOM CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 EXP PT-2 VAR
A-101
1/4" = 1'-0"
A-101
C1
TOILET 104 -NORTH ELEVATION
1/4" = 1'-0"
A-101
C2
TOILET 104 - EAST ELEVATION
1/4" = 1'-0"
A-101
C3
TOILET 104 - SOUTH ELEVATION
FULL SCALEC4
JOINT DETAIL
ROOM FINISH SCHEDULE - BRD 2
ROOM
NO. NAME
FLOORING BASE NORTH WALL EAST WALL SOUTH WALL WEST WALL CEILING
CEILING
HIEGHT REMARKS
SUBSTRATE
MATERIAL
FLOORING
SYSTEM
FLOORING
COLOR
SUBSTRATE
MATERIAL BASE SYSTEM BASE COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
SUBSTRATE
MATERIAL
FINISH
SYSTEM FINISH COLOR
101 GENERATOR ROOM CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 -- EXP PT-2 VAR
102 ELECTRICAL ROOM CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 -- EXP PT-2 VAR
103 FILE STORAGE ROOM CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 -- EXP PT-2 VAR
104 TOILET CONC SEAL -- CMU -- -- CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 CMU PT PT-1 -- EXP PT-2 VAR
1/2" = 1'-0"B1
TOILET ACCESSORIES MOUNTING HEIGHTS
0 6" 1'
3" = 1'-0"
3"
0 2'
1 1/2" = 1'-0"
6" 1'
1/2" = 1'-0"
1' 2' 4' 6'
1/4" = 1'-0"
2' 4' 8' 12'
FULL SCALE
0 1" 2" 3"
31 EXPOSED STRUCTURE - PAINTED, TYPICAL
32 MECHANICAL UNIT HEATER - REFER TO MECHANICAL
1. ALL STEEL DOORS AND FRAMES SHALL BE PAINTED.
2. ALL STEEL DOORS SHALL BE GALVANIZED.
3. ALL EXTERIOR DOORS SHALL BE INSULATED.
4. ALL EXIT DOOR HARDWARE SHALL ALLOW DOORS TO BE OPENED IN THE
DIRECTION OF EXIT WITHOUT THE USE OF A KEY OR SPECIAL
KNOWLEDGE OR EFFORT.
5. BOTH THE LATCHING AND DEAD BOLT DEVICES ON EXTERIOR DOORS
SHALL RELEASE WITH A SINGLE ACTION OF THE INSIDE LEVER.
6. HINGES FOR OUT-SWINGING EXTERIOR DOORS SHALL BE EQUIPPED WITH
NON-REMOVABLE HINGE PINS IF NOT SCHEDULED TO RECEIVE
CONTINUOUS HINGE.
7. THE DOOR FRAME MANUFACTURER SHALL VERIFY ACTUAL WALL /
PARTITION THICKNESS WITH CONTRACTOR PRIOR TO FABRICATION OF
DOOR FRAMES.
8. REFER TO SPECIFICATIONS FOR HARDWARE GROUPS.
9. OVERHEAD COILING DOOR SIZE INDICATED IS FOR FINISHED OPENING.
ACTUAL DOOR SIZE WILL BE LARGER BASED ON MANUFACTURER'S
STANDARDS.
DOOR SCHEDULE GENERAL NOTES
F FLUSH
HM HOLLOW METAL
MFR PER MANUFACTURER
OHC OVERHEAD COILING DOOR
STL STEEL
DOOR SCHEDULE LEGEND
1. 1 1/2" UNDERCUT ON DOOR.
2. LOUVER TO BE MINIMUM 12X12.
3. PROVIDE INTERIOR SIGNAGE AT THE STRIKE SIDE, ON EACH SIDE OF THIS
DOOR. SIGNAGE MESSAGE TO IDENTIFY THE ROOM NAME OF THE
ADJOINING SPACE.
4. FIRE RATED DOOR OPENING.
5. PROVIDE ELECTRO-MAGNETIC HOLD-OPEN DEVICE; WITH FIRE ALARM
INTERFACE
DOOR SCHEDULE REMARKS
R E
F E
R T
O S
C H
E D
U
LE
DOOR FRAME
FINISH FLOOR
2"
REFER TO
SCHEDULE 2"
4"
DOOR FRAME
FINISH FLOOR
2"
REFER TO
SCHEDULE 2"
R E
F E
R T
O S
C H
E D
U
LE
4"FULLY
ENCLOSED
HEAD
FLUSH DOOR
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
FOVERHEAD COILINGOH
PREFINISHED
STEEL SLATS
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
FLUSH DOOR
FLUSH PANEL
DOOR - REFER
TO SCHEDULE
FOR MATERIAL
L
REFER
TO SCHEDULE
R E
F E
R T
O S
C H
E D
U
LE
LOUVER
BOND BEAM - REFER TO
STRUCTURAL
REINFORCING - REFER TO
STRUCTURAL
CMU LINTEL
RAKE MORTAR BACK 1/2",
PROVIDE CONTINUOUS
SEALANT ON ALL SIDES
DOOR FRAME - GROUT SOLID
D O
O R
H E
IG
H
T
DOOR REFER TO SCHEDULE
EQ. 5 3/4" EQ.
4"
3/ 8"
REINFORCING - REFER TO
STRUCTURAL
CMU JAMB UNIT WITH
BULLNOSED CORNERS
GALVANIZED SHEET STEEL
"TEE" ANCHORS
RAKE MORTAR BACK 1/2", PROVIDE
CONTINUOUS SEALANT ON BOTH SIDES
DOOR FRAME - GROUT SOLID
DOOR - REFER TO SCHEDULE
EQ.5 3/4"EQ.
2" D
O O
R W
ID
T
H 3/
8"
D O
O R
H E
IG
H
T
DOOR FRAME(SOLID (4-
SIDED) FRAME) - INJECT
SOLID WITH FOAMED-IN-
PLACE INSULATION,
WELD CLOSE
INJECTION HOLES
DOOR - REFER TO
SCHEDULE
6"
ACCOMODATE LOUVER
AS REQ'D TO
4"
TYPE L-6 LOUVER
(SINGLE DOORS) OR
TYPE L-7 LOUVER
(DOUBLE DOORS) AND
BIRD SCREEN
INTEGRAL LOUVER
FLASHING SET IN
CONTINOUS SLEANANT
ON HORIZONTAL
SURFACE OF ANGLE -
SLOPE END TO DRAING
CMU BEYOND
BRICK VENEER
BEYOND
WALL THICKNESS
2"
3/
D O
O R
W
ID
T H
8 7/8" 5 3/4"
REINFORCING - REFER TO
STRUCTURAL
CMU JAMB UNIT WITH
BULLNOSED CORNER
GALVANIZED SHEET
STEEL "TEE" ANCHORS
RAKE MORTAR BACK 1/2",
PROVIDE CONTINUOUS
SEALANT ON BOTH SIDES
DOOR FRAME -
GROUT SOLID
DOOR - REFER
TO SCHEDULE
RETURN BRICK VENEER
TO 8" CMU
2" (R-9 MINIMUM)
THERMAL INSULATION
AIR CAVITY
BRICK VENEER
WALL THICKNESS
PROVIDE DAM FLASHING
FLUID APPLIED AIR BARRIER
SWEEP - REFER TO
HARDWARE SCHEDULE
THRESHOLD - SET IN
MASTIC AND ANCHOR PER
MANUFACTURER'S
RECOMMENDATION
EXTERIOR
SLOPE TO DRAIN
1/2" EXPANSION JOINT WITH
COMPRESSIBLE FILLER AND
1/2" DEEP SEALANT AT TOP
CONCRETE SLAB
DOOR AS SCHEDULED
FRAME BEYOND
BRICK VENEER BEYOND
6" 8 1/4"
INTERIOR
CMU BEYOND
7/
M
A X
IM
U
M 1/
2"
DOOR FRAME
UNDERCUT FROM CONCRETE
UNLESS OTHERWISE NOTED IN
DOOR SCHEDULE
CONCRETE SLAB
3/ 4"
DOOR AS SCHEDULED
EQ. 5 3/4" EQ.
CMU BEYOND
C
B
A
1 2 3 4 5
D E
S
IG
N E
D B
Y
D W
N B
Y
S U
B M
IT
T
E D
B Y
P
LO
T S
C A
LE
S
IZ
E
F
IL
E N
A M
E
IS
S
U E
D A
T E
C K
D B
Y
D A
T E
S O
LI
C
IT
A
T
IO
N N
O
C O
N T
R A
C T
N O
F
IL
E N
U M
B E
R
W
2P 8-
-X
O C
T . 2
A N
S I D
A E
C _S he et
S ee d.
dg n M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
M
A R
K D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
U .S
. A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S G
R E
E N
B R
O O
K F
LO
O
D R
IS
K
M A
N A
G E
M E
N T
P R
O
JE
C T
SHEET
IDENTIFICATION
SHEET OF 493
US Army Corps of Engineers
CONTRACT NO. 2 - 100% SUBMITTAL - JUNE 2022
D
N E
W Y
O R
K D
IS
T
R
IC
T N
E W
Y O
R K
, N E
W Y
O
B -B
A S
IN
O
F T
H E
R A
R
IT
A N
R
IV
E R
S E
G M
E N
T C
H C
O N
T R
A C
T N
O . 2
B O
R O
. O F
M
ID
D
LE
S E
X A
N D
G R
E E
N B
R O
O K
T W
P , N
J
J A C O B S
WORK ON THIS
SHEET IS IN THE
OPTION 2 CONTRACT
S tl fi l0
\p ro j\ F
W
\7 c a d d \7
A R
C H
\7
.1 R e v it \M o d e ls
\F W
G re e n
B ro o k N
J P u m p S ta ti o n s
A R
C H
.r v t
/2
/2
:1
:3
A
M
/2
/2
:1
:3
A
M
A-603
G . S
T A
U D
E R
K . B
A N
K S
B . H
E N
D O
N
M . H
E M
M E
R
A R
C H
IT
E
C T
U R
A L
D O
O R
S C
H E
D U
L E
T Y
P E
S A
N D
D E
T A
IL
S
DOOR SCHEDULE - BDR 3
NUMBER
DOOR FRAME FIRE
RATING REMARKSTYPE MATERIAL SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL
101A F HM 3'-0" x 7'-0" 1 3/4" 1 HM B1/A-603 B2/A-603 B3/A-603 --
101B OHC STL 9'-0" x 10'-0" MFR -- STL C4/A-604 B4/A-604 A4/A-604 --
101C F HM 3'-0" x 8'-0" 1 3/4" 2 HM A1/A-603 A2/A-603 A3/A-603 45 MIN 3, 4, AND 5
102 F HM (2) 3'-0" x 7'-0" 1 3/4" 1 HM B1/A-603 B2/A-603 B3/A-603 --
103A F HM 3'-0" x 7'-0" 1 3/4" 2 HM A1/A-603 A2/A-603 A3/A-603 -- 3
103B F HM (2) 3'-0" x 7'-0" 1 3/4" 1 HM B1/A-603 B2/A-603 B3/A-603 --
1/4" = 1'-0"D5
FRAME TYPES
1/4" = 1'-0"D4
DOOR TYPES
A-603
0 2'
1 1/2" = 1'-0"
6" 1'
1/4" = 1'-0"
2' 4' 8' 12'
3" = 1'-0"A1
HEAD DETAIL
3" = 1'-0"A2
JAMB DETAIL
A-603
0 6" 1'
3" = 1'-0"
3"
A-603
3" = 1'-0"
A-501
B1
HEAD DETAIL
3" = 1'-0"B2
JAMB DETAIL
A-603
3" = 1'-0"
A-501
B3
SILL DETAIL
A-603
3" = 1'-0"A3
SILL DETAIL
A-603
DOOR SCHEDULE - BRD 2
NUMBER
DOOR FRAME FIRE
RATING REMARKSTYPE MATERIAL SIZE: WIDTH x HEIGHT THICKNESS TYPE MATERIAL HEAD DETAIL JAMB DETAIL SILL DETAIL
101A F HM 3'-0" x 7'-0" 1 3/4" 1 HM B1/A-603 B2/A-603 B3/A-603 --
101B OHC STL 9'-0" x 10'-0" MFR -- STL C4/A-604 B4/A-604 A4/A-604 --
101C F HM 3'-0" x 8'-0" 1 3/4" 2 HM A1/A-603 A2/A-603 A3/A-603 45 MIN 3, 4, AND 5
102 F HM (2) 3'-0" x 7'-0" 1 3/4" 1 HM B1/A-603 B2/A-603 B3/A-603 --
103A F HM 3'-0" x 7'-0" 1 3/4" 2 HM A1/A-603 A2/A-603 A3/A-603 -- 3
103B F HM (2) 3'-0" x 7'-0" 1 3/4" 1 HM B1/A-603 B2/A-603 B3/A-603 --
104 L HM 3'-0" x 7'-0" 1 3/4" 2 HM A1/A-603 A2/A-603 A3/A-603 -- 1 AND 2
D O
O R
W
ID
T H
REINFORCING - REFER TO
STRUCTURAL
OVERHEAD COILING DOOR -
REFER TO SCHEDULE
RETURN MASONRY BRICK
VENEER FULL DEPTH OF JAMB
2" (R-9 MINIMUM)
THERMAL INSULATION
AIR CAVITY
BRICK VENEER
PROVIDE DAM FLASHING
FLUID APPLIED AIR BARRIER
VENEER
1' - 6" TO BRICK WALL THICKNESS
BOLLARD - REFER TO A5/A-531
ALIGN TANGENT OF BOLLARD
WITH FACE OF DOOR JAMB
BRICK VENEER
ANCHOR TO CMU PER
MANUFACTURER'S
REQUIREMENTS
GALVANIZED ANGLE JAMB GUIDES -
PRIME AND PAINT - CONTINUOUSLY
WELD TO STEEL ANGLE
W/ 1/2" X 5" LONG HEATDED
STUDS @ 16 OC EA LEG,
STAGGERED AT 8"OC
JOINT SEALANT
9" .
OVERHEAD COILING DOOR
CONCRETE FLOOR
1/2" RECESS IN CONCRETE
FLOOR AT SILL. COORDINATE
LOCATION WITH DOOR
MANUFACTURER
BOTTOM BARDOOR BOTTOM SWEEP
SLOPE CONCRETE
FLOOR DOWN 1/2" TO
PAVEMENT
BRICK VENEER BEYOND
SITE PAVEMENT - REFER
TO CIVIL
1/ 2"
JAMB ANGLE BEYOND
BOND BEAM - REFER TO…
This is the start of the file's text. The full file is on GovTribe.