CBP Vault Solicitation RFIs 09-01-2020.pdf

PDF 53 KB Posted

Attached to
Construction Contract for the Customs and Border Protection Seized Cargo Facility Federal contract opportunity
Solicitation number
47PF0020R0040
Issued by
General Services Administration Public Buildings Service Region 5

About this file

This document provides details for a federal construction contract solicitation for the Customs and Border Protection Seized Cargo Facility project in Detroit, Michigan. The General Services Administration seeks to award a firm-fixed price construction contract between $1-5 million to renovate existing office space, construct a new high-bay warehouse building connected to an existing facility, and complete associated site improvements. The project involves precast concrete and tilt-up construction additions, selective demolition, security fencing and wiring installations, and HVAC modifications. The solicitation will be available on July 14, 2020, with a pre-proposal conference on July 22, 2020 and proposals due on August 25, 2020. Award is targeted for January 2021. The contract is set aside for 8(a) small businesses and the construction work must be completed within 365 calendar days.

View the file

Other files for this federal contract opportunity

Other files attached to Construction Contract for the Customs and Border Protection Seized Cargo Facility, newest first.
File Type Posted
47PF0020R0040 - Amendment 08.pdf PDF
47PF0020R0040 - Amendment 07.pdf PDF
47PF0020R0040 - Amendment 06.pdf PDF
47PF0020R0040 - Amendment 05.pdf PDF
099600 - High-Performance Coatings.pdf PDF
CBP Vault Solicitation RFIs 8.25.2020.pdf PDF
018111 Sustainable Design Requirements FY15 Update Oct. 1 2014.pdf PDF
47PF0020R0040 - Amendment 04.pdf PDF
GC Reps and Certs Aug 2020 r1 8-19-2020.pdf PDF
CBP Vault Amendment 04 - Language.pdf PDF
CBP Site Visit Attendance.pdf PDF
CBP Vault Solicitation RFIs 8.19.2020.pdf PDF
CBP Vault Solicitation RFIs - Amendment 03.pdf PDF
47PF0020R0040 - Amendment 03.pdf PDF
CIO_P_21001I__CHGE_1_GSA_Information_Technology_IT_Security_Policy__Signed_on_10-20-2015.pdf PDF
CBP Pre-proposal Agenda - Final.pdf PDF
CBP 47PF0020R0040 RFI List from PreProposal Conf.pdf PDF
BrokerSCV-Walk-thru-20200722-FINAL.pdf PDF
David Bacon Wage Rates MI20190101 7.24.2020.pdf PDF
Pre. Prop. Attendance Sheet.pdf PDF
KSP Construction Product Tracking Form.pdf PDF
47PF0020R0040 - Amendment 02 PDF.pdf PDF
47PF0020R0040 - Amendment 01.pdf PDF
Site Visit Request Form - CBP Cargo Facility.pdf PDF
CBP Vault Supplemental Pricing Form - SF1442 Attachment R1.pdf PDF
GC Reps and Certs 07-14-2020.pdf PDF
GSA527-15e (1).pdf PDF
Past Performance Reference Questionnaire.pdf PDF
SBSA GC Solicitation 07-14-20.pdf PDF
CBP Cargo Facility Pre-Proposal RSVP Form.pdf PDF
SF24-16d.pdf PDF
CBP Vault Supplemental Pricing Form - SF1442 Attachment.pdf PDF
SBSA GC Agreement 07-14-20.pdf PDF
SF1442-14b - CBP Vault.pdf PDF
Show all 34

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Construction Contract for the Customs and Border Protection

Seized Cargo Facility

2810 West Fort Street, Detroit, Michigan

Solicitation # 47PF0020R0040

Amendment 07

Q) The High-Security Fence and Gates or Bollards section of this project does not appear to have a vehicle crash rating in order to protect the facility against vehicular threats. Has this been considered?

A) The current CBP vault design guide that specifies fence does not call for any crash rating.

No additional bollards or crash rating for the perimeter fence are required. The bollards around the entrance poles are still needed.

Q) Now that I see the fume hood location, the specified manufacturer, is asking what the hood will be used for. These ductless hoods are customized based on the application which is extremely important in designing the hood correctly, especially because they are ductless.

Depending on what they are testing in the hood, will determine the design and materials used.

A) The fume hood is used for processing narcotics and must have a HEPA filter. Add subsection “ 2.1-A.1.b Filter type: HEPA filter” to specification section 115313.

Q) My other question- Is GSA pricing required on this project?

A) Pricing is required per the wage rate determination published in the solicitation. Unless clearly specified, materials may be purchased by any vendor.

Q) Can a qualified Temperature Controls Contractor be used as an alternative to provide and install the Building Automation System (BAS)? The specifications 230900 indicate the intention to provide an expandable system free from single source suppliers. The specification states the

"Temperature Controls work shall match the existing building automation system (BAS)". An RFI was issued asking "who/what is the manufacturer of the BAS?" The answer was: "Johnson

Controls Metasys". Please clarify if alternates will be accepted such as the newer Tridium

Niagara Vykon N4 system. This proposed Tridium BAS system meets all of the specification requirements. It is an open source platform that allows other Temperature Controls companies to install/service.

A) No.The BAS is proprietary. Only JCI is able to supply parts and program the system.

Q) New text is highlighted yellow in regards to spec section 034100:

2.10 THIN BRICK AND ACCESSORIES

A. Products: Subject to compliance with requirements, provide the following:

1. Provide thin brick matching, or equal to, as approved by Architect and Government representative, to color, texture, and face size of existing adjacent brick work.

2. Basis of Design: Contractor to verify existing building brick information noted below.

a. Supplier:

1) Brick Tech Architectural Inc. – Attn: Robert Weeks

3040 W. Eleven Mile Rd.

Berkley, MI 48072

(248) 548-0777

b. Custom colors to match existing building brick:

1) Red field brick:

a) Endicott ‘Rose Blend’.

2) Beige decorative horizontal bands:

a) Glen Gery GCBC H56S (#56 Smooth from Hanley plant).

c. Face Size: 7-5/8 inches high by 7-5/8 inches long.

3. Acceptable manufacturers, subject to compliance with requirements:

a. Bowerston Shale Company.

Supplier: Arlington Masonry Supply - Attn: Jeff Prell

7500 23 Mile Road

Shelby Township, MI. 48316

(586) 980-1270